t k32 - conrad electronic · 2019-09-12 · contact type: normally closed t k32 operating...

6
Contact Type: Normally Closed TK32 Operating Temperature Range (+30 C to + 250 C) This is a temperature sensitive device, which is intended to keep a temperature below one particular value during normal operating conditions, automatically switching off the electrical circuit. This device is not self-resetting and operates with manual reset option. It prevents overheating in variety of consumer, industrial and commercial products. This temperature limiter is available only with contacts that open as the temperature increases. The contacts may be reset by manually pushing on the reset button after the device has cooled below the open temperature calibration. Besides its variety of standard configur ations this limiter can also be customized to the specific technical needs of the customer, assuring maximum design flexibilit y and usage in broad range of temperature control applications. Disc Temperature Limiter

Upload: others

Post on 18-Jun-2020

2 views

Category:

Documents


0 download

TRANSCRIPT

Page 1: T K32 - Conrad Electronic · 2019-09-12 · Contact Type: Normally Closed T K32 Operating Temperature Range (+30 C to + 250 C) This is a temperature sensitive device, which is intended

Contact Type: Normally Closed

T K32Operating Temperature Range (+30 C to + 250 C)This is a temperature sensitive device, which is intended to keep a temperature below one particular value during normal operatingconditions, automatically switching off the electrical circuit. Thisdevice is not self-resetting and operates with manual reset option.It prevents overheating in variety of consumer, industrial andcommercial products.

This temperature limiter is available only with contacts that openas the temperature increases. The contacts may be reset bymanually pushing on the reset button after the device has cooledbelow the open temperature calibration.

Besides its variety of standard configurations this limiter canalso be customized to the specific technical needs of the customer,assuring maximum design flexibility and usage in broad range oftemperature control applications.

Disc Temperature Limiter

Page 2: T K32 - Conrad Electronic · 2019-09-12 · Contact Type: Normally Closed T K32 Operating Temperature Range (+30 C to + 250 C) This is a temperature sensitive device, which is intended

o Tolerance of temperature limiter operating temperature, %, but not less than C

Parameter

Parameter

Value

Value

~ 2 5 0

~ 2 5 0

16

16

10

10

10 000

10 000

3

3

50

50

1500

1500

30 to 170

170 to 250

Rated voltage, V, not more

Rated voltage, V, not more

Rated current, A, at power coeff. 0,95, not more

Rated current, A, at power coeff. 0,95, not more

Rated current, A, at power coeff. 0,6, not more

Rated current, A, at power coeff. 0,6, not more

Number of automatic cycles, at rated current 16 А and power coeff. 0,95, not less than

Number of automatic cycles, at rated current 16 А and power coeff. 0,95, not less than

Electric strength of insulation, V, not less than

Electric strength of insulation, V, not less than

Heating speed, K/min

Heating speed, K/min

minimum-0,1; maximum-1,0

minimum-0,1; maximum-1,0

Degrees of protection provided by enclosure

Degrees of protection provided by enclosure IP4X; I P64

I P64IP4X;

0 , 0 1 ; 0,05

0 , 0 5

Contact operating time, ms, not more

Contact operating time, ms, not more

Tolerance of operating temperature, %

о Operating temperature, С

о Operating temperature, С

_ BASIC TECHNICAL DATA FOR TK32 (30 C 170 C)

_ BASIC TECHNICAL DATA FOR TK32 (170 C 250 C)

Page 3: T K32 - Conrad Electronic · 2019-09-12 · Contact Type: Normally Closed T K32 Operating Temperature Range (+30 C to + 250 C) This is a temperature sensitive device, which is intended

25

14.5

4.8

0.8

14.5

11.73.2

9.9

0.5

14.5

4.53.2

44

0.5

26.3

3

14.5

50.

5

3

14.5

5

50.

5

30

1.6

14.5

6.3

7.5

0.8

35

27

1.6

14.5

6.3

0.8

14.5

140.8

6.3

10.7

T 03

T 05

T 07

T 09

T 11

T 13

T 04

T 02T 01

T 06

T 08

T 10

T 12

T 14

14.5

8.5

Wire standardlength: 150 mm

14.5

140.8

9

31

1.6

14.5

4.8

4.84.8

0.8

23

14.50.8

2.1

Table 1.1 (TERMINALS)

14.5Wire information to be

specified on the order form (type; cross-section; lengths; stripping)

14.5

8.5

0.5

3 1.5

2

2.7

Soldering balls

Page 4: T K32 - Conrad Electronic · 2019-09-12 · Contact Type: Normally Closed T K32 Operating Temperature Range (+30 C to + 250 C) This is a temperature sensitive device, which is intended

MG 00

MG 02

MG 04

MG 06

MG 08

MG 01

MG 03

MG 05

MG 07

NO MOUNTING

CAP-FLANGE

CLIP WITHONE FIXINGHOLE

SCREW CAPROUND

SCREW CAPHEXAHEDRAL 16

ROTATION ORFIXED CLIP

ROTATIONCLIP

TUBEMOUNTING

SCREW CAPHEXAHEDRAL 17

Screw parameters (MX, L) to be specifiedon the order form

Screw parameters (MX, L) to be specifiedon the order form

Screw parameters (MX, L) to be specifiedon the order form

Table 1.2 (MOUNTING)

14.5

15.8

0.5

23.8

18.2

0.1

0.2

3.8

30.4 0.2

14.5

23.8±0.1

20.4

5

15.830.4

14.5

35.5 0.1

3.8

42.25 0.2

14.5

0.5

14.5

13

15.8

0.4

25.2

8

4.0

2

1.9

3.8

18.2

4

16

MX

17

L

16

MX

L

MX

L

14.514.5

23

14.5

3.8

Tube diameter: 14-20 mm

Page 5: T K32 - Conrad Electronic · 2019-09-12 · Contact Type: Normally Closed T K32 Operating Temperature Range (+30 C to + 250 C) This is a temperature sensitive device, which is intended

B1C B1CR

B2P B2PR

B2C B2CR

B3C B3CR

B4S

B1P B1PRPLASTIC BODY

Table 1.3 (BODY and/or CASE)

PLASTIC BODY

CERAMIC BODY

CERAMIC BODY

CERAMIC BODY

T K321

12345

42 53MGX** ***T X* BXX

PART ORDERING SYSTEM

Temperature limiter model

Only with cables Protection degree IP64

Mounting version (select from Table 1.2)

Terminals version (select from Table 1.1)

Body version (select from Table 1.3)

+ Operating temperature value in C and tolerance in %***-

*For wire terminals, lead wire parameters must be specified when placing an order:insulation type, cross-section area; ends type; lenght; etc.

Example: TK32-T01-MG04-B2C-60±3%

**For screw cap mountings, screw parameters must be specified when placing an order.

***Tolerance in % or C, whichever numerical value is bigger.

14.5

10.2

14.5

7.2 5

14.5

7.2 5

14.5

10.2

55

20

16

20

16

23

16

23

16

23

16

35

20

2

15

14.5 14

14.5

6.210

.7

19.5

SILICONE CASING

Protection cap with rubber button

Protection cap with rubber button

Protection cap with rubber button

Protection cap with rubber button

Protection cap with rubber button

Page 6: T K32 - Conrad Electronic · 2019-09-12 · Contact Type: Normally Closed T K32 Operating Temperature Range (+30 C to + 250 C) This is a temperature sensitive device, which is intended

Address: “Thermorex” SAS, 18, rue Pasquier, 75008 Paris, Francetel.: +31(0) 61 55 22 880, e-mail: [email protected], [email protected] plant: “Thermorex” CJSC, 24/41 Fuchik str., 0048, Yerevan, Armeniatel.: +37410 39 58 84, 37410 34 93 51, fax: +37410 34 98 86, e-mail: [email protected], [email protected]