swisspump nds 50hz

96
7/21/2019 Swisspump Nds 50hz http://slidepdf.com/reader/full/swisspump-nds-50hz 1/96 NDS Single stage double suction Split casing centrifugal pump

Upload: nour-nour-el-islam

Post on 05-Mar-2016

254 views

Category:

Documents


1 download

DESCRIPTION

spilt case pump 50 hz

TRANSCRIPT

Page 1: Swisspump Nds 50hz

7/21/2019 Swisspump Nds 50hz

http://slidepdf.com/reader/full/swisspump-nds-50hz 1/96

NDS

Single stage double suctionSplit casing centrifugal pump

Page 2: Swisspump Nds 50hz

7/21/2019 Swisspump Nds 50hz

http://slidepdf.com/reader/full/swisspump-nds-50hz 2/96

Approvals

 Michael Drechsel 

 President of IQNet 

 Roland Glauser 

 Managing Director SQS 

CERTIFICATE IQNet and SQS

hereby certify that the organisation

 

has implemented and maintains a

Management System

ISO 9001:2008 

Issued on: 2012-02-20

Validity date: 2015-02-19

Registration Number: CH-32160 

Whole Company

Swiss Pump Company AG3645 Thun-Gwatt

Switzerland

Design, development, manufacture and sale of products

for the transportation of liquids

IQNet Partners*:

 

 

   

Page 3: Swisspump Nds 50hz

7/21/2019 Swisspump Nds 50hz

http://slidepdf.com/reader/full/swisspump-nds-50hz 3/963

General Data

Application page 4

Operating condition 4

Design 4

Bearing 4

Definition of model 4

Parts 5

Pump and motor arrangement  6

Materials 7

Shaft diameter and bearing 8

Min. Working pressure 10

Impeller, Nozzle forces and moments 11

Arrangement 12

Venting connections and bearing sensor 13

Section view Horizontal installation 14

Section view Vertical installation 15

Section view Shaft seal 16

Section view Mechanical seal 17

Section view Rotor 18Section view Bearing 19

Bare shaft pump dimensions 22

Performance scope 24

Performance curves 26

Page 4: Swisspump Nds 50hz

7/21/2019 Swisspump Nds 50hz

http://slidepdf.com/reader/full/swisspump-nds-50hz 4/96

   G   e   n   e   r   a   l

   D   a   t   a

4

NDS 200 - 125 - 290 V

  Vertical type 

Impeller nominal diameter(mm)

  Discharge size(mm)

Suction size(mm)

Design

Type: Axially Split volute casing pump with duble suction impeller

Flange:  GB, ISO, DIN, BS, ANSI

Material: 

Casing: Cast Iron, Ductile Iron, Cast Steel, Stainless SteelImpeller: Bronze, Cast Iron, Stainless Steel, Dublex S.S

Shaft : SS420, Duplex stainless steel

Shaft Seal: Optional

Operating Condition

Flow Rate(Q) : 50 to 20000m3/h

Head(H) : 10 to 230m

Suction Dia. : 100 to 1400mmDischarge Dia. : 80 to 1200mm

Normal temperature type : -15°C ~ +80°C,

Hot water type : +80°C ~ +200°C

Clean water or medium similer to water in physical and chemical properties

• Water supply: Drainage, Irrigation, Power station, Fire-fighting, Air-conditioning, Building industry,

Marine applications.

• Apprasive medium: Sand water, Oxide scale water.

• Corrosive medium: Desalination, Bittern, Sea water.

• Water treatment: Ultrafiltration system, reverse osmosis system, distillation system, separator, swimming pool

Pump can be design according to API610 BB1 type service for petroleum, petrochemical and natural gas industries.

Application

Definition of Model

NDS  Split case pump

Bearing

Horizontal:Grease lubricated ball bearings on both side, oil lubrication is optional.

Sliding bearing is available for big size pump.

Vertical: Grease lubricated ball bearings.

Page 5: Swisspump Nds 50hz

7/21/2019 Swisspump Nds 50hz

http://slidepdf.com/reader/full/swisspump-nds-50hz 5/965

Parts

Casing

In-line axially split design which permits removal of

the complete rotor without moving the pipe and motor.

Short distance between bearings.

Leak-tight due to compact joint flange with long,

prestressed bolts.

Counter-rotation possible with similar parts.

Double volute casing reduces radial forces on the

impeller and consequently the bearing loads.

Easy mounting self-aligning upper casing.

Flange drilled to ISO, DIN, BS or ANSI

Smooth surface inside and epoxy coating as required.Replacable wear rings protect the casing at the impeller

running clearances.

Excelent efficiencies and outstanding NPSH.

Bearing

SKF covered, sealed for life grease lubricated antifriction

bearing for long service life.

Open gland, enough space for service activities.

Optional: oil lubrication with constant level oiler.

Seal

Asbestos-free, potable water quality soft-packed

stuffing boxes.

Unbalanced mechanical seal, according to DIN24960.

Balance mechanical seal for operating pressure > 16bar

Cartridge-type mechanical seal on required.wear and

abrasive resistance.

The materials are FDA compliant materials.

Impeller Bowls are made from Stainless steel 304

maximizing wear from abrasion.

Shaft

Heavy duty shaft completely sealed and dry for zero

corrosion.

Short and rigid with negligable vibrations.

Replaceable shaft protecting sleeves.

No threads exposed to pumpes medium.

Long operation life and no corrosion.

Adjustment-free assembly.

Quick and easy assembly / dismantling of the rotor

components due to elastically prestressed mountings.

Maximum interchangeability shafts design.

Entire series for 2900rpm and 1450rpm models just six shaft and six bearing assemblies.

Impeller

Computer-optimized double entry impellers.

Minimal axial thrust due to double-entry impeller.

Impeller is statically and dynamically balanced

according to ISO 1940.

Optional impeller wear rings.

New vane passage with excellent hydraulic

characteristics high-performance.

Page 6: Swisspump Nds 50hz

7/21/2019 Swisspump Nds 50hz

http://slidepdf.com/reader/full/swisspump-nds-50hz 6/96

   G   e   n   e   r   a   l

   D   a   t   a

6

Pump and Motor Arrangement

Page 7: Swisspump Nds 50hz

7/21/2019 Swisspump Nds 50hz

http://slidepdf.com/reader/full/swisspump-nds-50hz 7/967

Standard materials

Part Clean Water

Water with mud and sand

Oxide scale water

Sewage / Saline water

Sea water Hot water

Casing Cast iron

Nicel chromium cast iron

Wear resistant cast iron

Cast steel

Wear resistant coating

Duplex stainless steel

Ductile CI

Cast steel

Stainless steel

Impeller

CI

Bronze

Stainless steel

Ductile CI

SS420

Stainless steel

Duplex stainless steelSS420

Stainless steel

Bearing housing Cast iron Cast iron Cast iron Cast iron

Shaft SS420 SS420 Duplex stainless steelSS420

Stainless steel

Wear ring Cast ironDuctile CI

SS420

Bronze

Suplex stainless steel

with hardening treatment

Ductile CI

Cast steel

Shaft sleeve SS420 SS420 Duplex stainless steel SS420

Shafy sealPacking

Mechanical seal

Packing

Mechanical sealMechanical seal Mechanical seal

Flushing pipeline Q235-A Q235-A 316LQ235-A

Stainless steel

• for Petrochemical liquids: According to API610, I-1, I-2, S-5, S-8, C-6, A-7, A-8, D-1, D-2.

Page 8: Swisspump Nds 50hz

7/21/2019 Swisspump Nds 50hz

http://slidepdf.com/reader/full/swisspump-nds-50hz 8/96

   G   e   n   e   r   a   l

   D   a   t   a

8

Shaft Nominal

Sealed

chamberD

sealed

chamberL

Bearing Mechanical seal Pump structure

NDS 125-80-210

NDS 125-80-270

NDS 125-80-350

NDS 150-100-250

NDS 150-100-320

NDS 150-100-400

NDS 200-125-240

NDS 200-125-300

NDS 200-125-380

NDS 200-125-480

NDS 200-150-290

NDS 200-150-360

NDS 200-150-460

NDS 200-150-570

NDS 250-200-340

NDS 250-200-430

NDS 250-200-530

NDS 250-200-660

NDS 300-250-270

NDS 300-250-280

NDS 300-250-390 65 80 110 93 6313 FAGM74N/80-G92-Q2BVV

(Mechanical seal Type B)

Horizontal installation

 Type C

NDS 300-250-490

NDS 300-250-610

NDS 300-250-780 85 110 150 130 6318 SKFM75N/110-G92-Q2BVV

(Mechanical seal Type A)

Horizontal installation

 Type A

NDS 350-300-310

NDS 350-300-330

6315 SKFM74N/90-G92-Q2BVV

(Mechanical seal Type A)

Horizontal installation

 Type A

65 80 110 93 6313 FAGM74N/80-G92-Q2BVV

(Mechanical seal Type B)

Horizontal installation

 Type C

75 90 120 92

6313 FAGM74N/80-G92-Q2BVV

(Mechanical seal Type B)

Horizontal installation

 Type C

55 70 95 85 6311 SKFM74N/70-G92-Q2BVV

(Mechanical seal Type B)

Horizontal installation

 Type C

65 80 110 93

6311 SKFM74N/70-G92-Q2BVV

(Mechanical seal Type B)

Horizontal installation

 Type C

55 70 95 85 6311 SKFM74N/70-G92-Q2BVV

(Mechanical seal Type B)

Horizontal installation

 Type C

55 70 95 85

M74N/60-G92-Q2BVV

(Mechanical seal Type B)

Horizontal installation

 Type C

45 60 85 82 6309 SKFM74N/60-G92-Q2BVV

(Mechanical seal Type B)

Horizontal installation

 Type C

60 85 82 6309SKF45

Horizontal installation

 Type C35 50 75 72 6307 SKF

M74N/50-G92-Q2BVV

(Mechanical seal Type B)

Model

Dimensions [mm]

35 50 75 72 6307 SKFM74N/50-G92-Q2BVV

(Mechanical seal Type B)

Horizontal installation

 Type C

Shaft diameter, Shaft seal and bearing

• Values are valid for the pumps under normal pressure and temperature, if the temp more than 80°C please contact SPCO.

Page 9: Swisspump Nds 50hz

7/21/2019 Swisspump Nds 50hz

http://slidepdf.com/reader/full/swisspump-nds-50hz 9/969

Shaft Nominal

Sealed

chamberD

sealed

chamberL

Bearing Mechanical seal Pump structure

NDS 400-300-450 75 90 120 92 6315 SKFM74N/90-G92-Q2BVV

(Mechanical seal Type A)

Horizontal installation

 Type A

NDS 400-300-570

NDS 400-300-700

NDS 400-350-360

NDS 400-350-380

NDS 400-350-520 85 110 150 130 6318 SKFM74N/110-G92-Q2BVV

(Mechanical seal Type A)

Horizontal installation

 Type A

NDS 450-450-350 75 90 120 92 6315 SKFM74N/90-G92-Q2BVV

(Mechanical seal Type A)

Horizontal installation

 Type A

NDS 500-300-780

NDS 500-300-920

NDS 500-400-400

NDS 500-400-420

NDS 500-400-540 100 135 180 150NU321

6321 SKF

M74N/135-G92-Q2BVV

(Mechanical seal Type A)

Horizontal installation

 Type B

NDS 500-400-570 75 90 120 92 6315 SKFM74N/90-G92-Q2BVV

(Mechanical seal Type A)

Horizontal installation

 Type A

NDS 500-400-660 100 135 180 150NU321

6321 SKF

M74N/135-G92-Q2BVV

(Mechanical seal Type A)

Horizontal installation

 Type B

NDS 500-400-675 85 110 150 130 6318 SKFM74N/110-G92-Q2BVV

(Mechanical seal Type A)

Horizontal installation

 Type A

NDS 600-400-740

NDS 600-450-640

NDS 600-500-520 80 115 160 170 6317 FAGM74N/115-G92-Q2BVV

(Mechanical seal Type A)

Horizontal installation

 Type A

NDS 600-500-550

NDS 600-500-580

NDS 700-500-670 100 135 180 150NU321

6321 SKF

M74N/135-G92-Q2BVV

(Mechanical seal Type A)

Horizontal installation

 Type B

NDS 700-500-940 130 170 215 176NU328

6328 SKF

M74N/170-G92-Q2BVV

(Mechanical seal Type A)

Horizontal installation

 Type A

NDS 700-600-600

NDS 700-600-680

NDS 700-600-740 115 150 195 180NU324

6324 SKF

M74N/150-G92-Q2BVV

(Mechanical seal Type A)

Horizontal installation

 Type A

NDS 800-700-750 120 160 205 170NU326

6326 SKF

M74N/160-G92-Q2BVV

(Mechanical seal Type A)

Horizontal installation

 Type B

13015011085

NU324

6324 SKF

M74N/150-G92-Q2BVV

(Mechanical seal Type A)

Horizontal installation

 Type A

Horizontal installation

 Type A

M74N/110-G92-Q2BVV

(Mechanical seal Type A)6318 SKF

100 135 180

195

80 115 160 170

100 135 180 150NU321

6321 SKF

M74N/135-G92-Q2BVV

(Mechanical seal Type A)

Horizontal installation

 Type B

M74N/115-G92-Q2BVV

(Mechanical seal Type A)

Horizontal installation

 Type A6320 SKF

150NU321

6321 SKF

M74N/135-G92-Q2BVV

(Mechanical seal Type A)

6315 SKFM74N/90-G92-Q2BVV

(Mechanical seal Type A)

Horizontal installation

 Type A

Horizontal installation

 Type A

Horizontal installation

 Type B

180

75 90 120 92

115 150

75 90 120 92 6315 SKFM74N/90-G92-Q2BVV

(Mechanical seal Type A)

Model

Dimensions [mm]

Shaft diameter, Shaft seal and bearing

• Values are valid for the pumps under normal pressure and temperature, if the temp more than 80°C please contact SPCO.

Page 10: Swisspump Nds 50hz

7/21/2019 Swisspump Nds 50hz

http://slidepdf.com/reader/full/swisspump-nds-50hz 10/96

   G   e   n   e   r   a   l

   D   a   t   a

10

Model Operating pressure Model Operating pressure

NDS 125-80-210 1.6 NDS 400-300-450 1.6

NDS 125-80-270 1.6 NDS 400-300-570 1.6

NDS 125-80-350 1.6 NDS 400-300-700 2.5

NDS 150-100-250 1.6 NDS 400-350-360 1.6

NDS 150-100-320 1.6 NDS 400-350-380 1.6

NDS 150-100-400 1.6 NDS 400-350-520 1.6

NDS 200-125-240 1.6 NDS 450-450-350 1.0

NDS 200-125-300 1.6 NDS 500-300-780 4.0

NDS 200-125-380 1.6 NDS 500-300-920 2.5

NDS 200-125-480 1.6 NDS 500-400-400 1.6

NDS 200-150-290 1.6 NDS 500-400-420 1.6

NDS 200-150-360 1.6 NDS 500-400-540 1.6

NDS 200-150-460 1.6 NDS 500-400-570 1.0

NDS 200-150-570 2.5 NDS 500-400-660 2.5

NDS 250-200-340 1.6 NDS 500-400-675 1.0

NDS 250-200-430 1.6 NDS 600-400-740 1.6

NDS 250-200-530 1.6 NDS 600-450-640 1.6

NDS 250-200-660 2.5 NDS 600-500-520 1.0

NDS 300-250-270 1.6 NDS 600-500-550 1.0

NDS 300-250-280 1.6 NDS 600-500-580 1.0

NDS 300-250-390 1.6 NDS 700-500-670 1.6

NDS 300-250-490 1.6 NDS 700-500-940 2.5

NDS 300-250-610 2.5 NDS 700-600-600 1.0

NDS 300-250-780 3.0 NDS 700-600-680 1.0

NDS 350-300-310 1.6 NDS 700-600-740 1.6

NDS 350-300-330 1.6 NDS 800-700-750 1.0

• Note: Values are valid for casing materials cast iron, for higher values, the other materials with better strength are available.

• Standard test pressure: 1.5xH + Suction pressureDuty point

Pressure limits

Page 11: Swisspump Nds 50hz

7/21/2019 Swisspump Nds 50hz

http://slidepdf.com/reader/full/swisspump-nds-50hz 11/9611

Impeller, Nozzle forces and Nozzle moments

• Note: Values are valid for casing materials cast iron, for casing material ductile cast iron use 1.4-fold, and for cast steel use 1.7.

If require for dimension of pump which is not shown in the above table, please contact SPCO.

Page 12: Swisspump Nds 50hz

7/21/2019 Swisspump Nds 50hz

http://slidepdf.com/reader/full/swisspump-nds-50hz 12/96

   G   e   n   e   r   a   l

   D   a   t   a

12

Arrangement

Page 13: Swisspump Nds 50hz

7/21/2019 Swisspump Nds 50hz

http://slidepdf.com/reader/full/swisspump-nds-50hz 13/9613

Venting connections and bearing temperature sensor

Page 14: Swisspump Nds 50hz

7/21/2019 Swisspump Nds 50hz

http://slidepdf.com/reader/full/swisspump-nds-50hz 14/96

   G   e   n   e   r   a   l

   D   a   t   a

14

Sectional view • Horizontal installation (Type A)

Sectional view • Horizontal installation (Type B)

Part Number Part Name

02.05.001 Shaft circlip

05.02.005 Bearing assembly (DE)

05.02.002 Rotor assembly

04.02.002 Upper casing

02.17.019 Name plate

04.09.001 Casing wear ring

05.02.001 Flushing water piping

05.02.006 Bearing assembly (NDE)

02.01.002 Bolt

05.02.003 Packing seal assembly

04.02.001 Lower casing

05.02.004 Mechanical seal assembly

05.02.007 Drainage piping

02.07.002 Wear ring dowel pin

 

Part Number Part Name

02.05.001 Shaft circlip

05.02.005 Bearing assembly (DE)

05.02.002 Rotor assembly

04.02.002 Upper casing

02.17.019 Name plate

04.09.001 Casing wear ring

05.02.001 Flushing water piping

05.02.006 Bearing assembly (NDE)

02.01.002 Bolt

05.02.003 Packing seal assembly

04.02.001 Lower casing

05.02.004 Mechanical seal assembly

02.16.002 Plug

02.07.002 Wear ring dowel pin

Page 15: Swisspump Nds 50hz

7/21/2019 Swisspump Nds 50hz

http://slidepdf.com/reader/full/swisspump-nds-50hz 15/9615

Sectional view • Horizontal installation (Type C)

Sectional view • Vertical installation

  Part Number Part Name

  02.05.001 Shaft circlip

  05.02.005 Bearing assembly (DE)

  05.02.002 Rotor assembly

  04.02.002 Upper casing

  02.17.019 Name plate

  04.09.001 Casing wear ring

  05.02.001 Flushing water piping

  05.02.006 Bearing assembly (NDE)

02.01.002 Bolt

  05.02.003 Packing seal assembly

  04.02.001 Lower casing

  05.02.004 Mechanical seal assembly

  02.16.002 Plug

  02.07.002 Wear ring dowel pin

 

Part Number Part Name

  02.05.001 Shaft circlip

  05.02.005 Bearing assembly (DE)

  05.02.002 Rotor assembly

  04.02.002 Upper casing

  02.17.019 Name plate

  04.09.001 Casing wear ring

  05.02.001 Flushing water piping

  04.02.006 Cap

04.02.035 Motor riser

  02.01.002 Bolt

  04.02.001 Lower casing

  05.02.004 Mechanical seal assembly

04.01.022 Bearing bush

  02.07.002 Wear ring dowel pin

04.02.030 Foot

Page 16: Swisspump Nds 50hz

7/21/2019 Swisspump Nds 50hz

http://slidepdf.com/reader/full/swisspump-nds-50hz 16/96

   G   e   n   e   r   a   l

   D   a   t   a

16

Sectional view • Shaft seal (Type A)

Sectional view • Shaft seal (Type B)

Part Number Part Name

04.02.012 Set neck ring

02.11.003 Gland packing

04.09.002 Lantern ring

04.02.022 Shaft protecting sleeve

04.09.005 Gland

02.03.003 Nut

02.02.002 Bolt

02.03.004 Round nut

 

Part Number Part Name

04.09.005 Gland

04.02.022 Shaft protecting sleeve

04.02.012 Set neck ring

02.11.003 Gland packing

04.09.002 Lantern ring

02.13.001 O-Ring

02.03.003 Nut

02.02.002 Bolt

Page 17: Swisspump Nds 50hz

7/21/2019 Swisspump Nds 50hz

http://slidepdf.com/reader/full/swisspump-nds-50hz 17/9617

Sectional view • Mechanical seal (Type A)

Sectional view • Mechanical seal (Type B)

  Part Number Part Name

  04.02.011 Seal cover

  04.02.023 Shaft protecting sleeve

  02.03.004 Round nut

  02.06.001 Round pin

02.13.004 Shaft seal unit

02.03.003 Nut

02.02.002 Bolt

  02.13.001 O-Ring

 

Part Number Part Name

04.02.011 Seal cover

  04.02.023 Shaft protecting sleeve

  02.06.001 Round pin

  02.13.004 Shaft seal unit

  02.02.002 Bolt

02.03.003 Nut

02.13.001 O-Ring

04.02.015 Shaft seal housing

04.02.020 Spacer sleeve

Page 18: Swisspump Nds 50hz

7/21/2019 Swisspump Nds 50hz

http://slidepdf.com/reader/full/swisspump-nds-50hz 18/96

   G   e   n   e   r   a   l

   D   a   t   a

18

Sectional view • Rotor (Type A)

Sectional view • Rotor (Type B)

Page 19: Swisspump Nds 50hz

7/21/2019 Swisspump Nds 50hz

http://slidepdf.com/reader/full/swisspump-nds-50hz 19/9619

Sectional view • Rotor (Type C)

Sectional view • Bearing (Type A)

Page 20: Swisspump Nds 50hz

7/21/2019 Swisspump Nds 50hz

http://slidepdf.com/reader/full/swisspump-nds-50hz 20/96

   G   e   n   e   r   a   l

   D   a   t   a

20

Sectional view • Bearin (Type B)

Sectional view • Bearing (Type C)

Page 21: Swisspump Nds 50hz

7/21/2019 Swisspump Nds 50hz

http://slidepdf.com/reader/full/swisspump-nds-50hz 21/9621

Sectional view • Bearing with oil lubrication

Sectional view • Bearing with water cooling (Pumping higher temp. liquid)

Page 22: Swisspump Nds 50hz

7/21/2019 Swisspump Nds 50hz

http://slidepdf.com/reader/full/swisspump-nds-50hz 22/96

   G   e   n   e   r   a   l

   D   a   t   a

22

Bare Shaft Pump Dimensions

Page 23: Swisspump Nds 50hz

7/21/2019 Swisspump Nds 50hz

http://slidepdf.com/reader/full/swisspump-nds-50hz 23/9623

Bare Shaft Pump Dimensions

Page 24: Swisspump Nds 50hz

7/21/2019 Swisspump Nds 50hz

http://slidepdf.com/reader/full/swisspump-nds-50hz 24/96

   T   e   c   h   n   i   c   a   l

   D   a   t   a

24

Performance Scope

Page 25: Swisspump Nds 50hz

7/21/2019 Swisspump Nds 50hz

http://slidepdf.com/reader/full/swisspump-nds-50hz 25/9625

Performance Scope

Page 26: Swisspump Nds 50hz

7/21/2019 Swisspump Nds 50hz

http://slidepdf.com/reader/full/swisspump-nds-50hz 26/96

   T   e   c   h   n   i   c   a   l

   D   a   t   a

26

NDS 125-80-210 , n=2980RPMHead and power ratings apply to media with a density of ρ=1kg-dm3 and a kinetic viscosity of 20mm2/s.

Page 27: Swisspump Nds 50hz

7/21/2019 Swisspump Nds 50hz

http://slidepdf.com/reader/full/swisspump-nds-50hz 27/9627

NDS 125-80-270 , n=2980RPMHead and power ratings apply to media with a density of ρ=1kg-dm3 and a kinetic viscosity of 20mm2/s.

Page 28: Swisspump Nds 50hz

7/21/2019 Swisspump Nds 50hz

http://slidepdf.com/reader/full/swisspump-nds-50hz 28/96

   T   e   c   h   n   i   c   a   l

   D   a   t   a

28

NDS 125-80-350 , n=2980RPMHead and power ratings apply to media with a density of ρ=1kg-dm3 and a kinetic viscosity of 20mm2/s.

Page 29: Swisspump Nds 50hz

7/21/2019 Swisspump Nds 50hz

http://slidepdf.com/reader/full/swisspump-nds-50hz 29/9629

NDS 150-100-250 , n=2980RPMHead and power ratings apply to media with a density of ρ=1kg-dm3 and a kinetic viscosity of 20mm2/s.

Page 30: Swisspump Nds 50hz

7/21/2019 Swisspump Nds 50hz

http://slidepdf.com/reader/full/swisspump-nds-50hz 30/96

   T   e   c   h   n   i   c   a   l

   D   a   t   a

30

NDS 150-100-320 , n=2980RPMHead and power ratings apply to media with a density of ρ=1kg-dm3 and a kinetic viscosity of 20mm2/s.

Page 31: Swisspump Nds 50hz

7/21/2019 Swisspump Nds 50hz

http://slidepdf.com/reader/full/swisspump-nds-50hz 31/9631

NDS 150-100-400 , n=2980RPMHead and power ratings apply to media with a density of ρ=1kg-dm3 and a kinetic viscosity of 20mm2/s.

Page 32: Swisspump Nds 50hz

7/21/2019 Swisspump Nds 50hz

http://slidepdf.com/reader/full/swisspump-nds-50hz 32/96

   T   e   c   h   n   i   c   a   l

   D   a   t   a

32

NDS 200-125-240 , n=2980RPMHead and power ratings apply to media with a density of ρ=1kg-dm3 and a kinetic viscosity of 20mm2/s.

Page 33: Swisspump Nds 50hz

7/21/2019 Swisspump Nds 50hz

http://slidepdf.com/reader/full/swisspump-nds-50hz 33/9633

NDS 200-125-300 , n=2980RPMHead and power ratings apply to media with a density of ρ=1kg-dm3 and a kinetic viscosity of 20mm2/s.

Page 34: Swisspump Nds 50hz

7/21/2019 Swisspump Nds 50hz

http://slidepdf.com/reader/full/swisspump-nds-50hz 34/96

   T   e   c   h   n   i   c   a   l

   D   a   t   a

34

NDS 200-125-380 , n=2980RPMHead and power ratings apply to media with a density of ρ=1kg-dm3 and a kinetic viscosity of 20mm2/s.

Page 35: Swisspump Nds 50hz

7/21/2019 Swisspump Nds 50hz

http://slidepdf.com/reader/full/swisspump-nds-50hz 35/9635

NDS 200-150-290 , n=2980RPMHead and power ratings apply to media with a density of ρ=1kg-dm3 and a kinetic viscosity of 20mm2/s.

Page 36: Swisspump Nds 50hz

7/21/2019 Swisspump Nds 50hz

http://slidepdf.com/reader/full/swisspump-nds-50hz 36/96

   T   e   c   h   n   i   c   a   l

   D   a   t   a

36

NDS 125-80-210 , n=1480RPMHead and power ratings apply to media with a density of ρ=1kg-dm3 and a kinetic viscosity of 20mm2/s.

Page 37: Swisspump Nds 50hz

7/21/2019 Swisspump Nds 50hz

http://slidepdf.com/reader/full/swisspump-nds-50hz 37/9637

NDS 125-80-270 , n=1480RPMHead and power ratings apply to media with a density of ρ=1kg-dm3 and a kinetic viscosity of 20mm2/s.

Page 38: Swisspump Nds 50hz

7/21/2019 Swisspump Nds 50hz

http://slidepdf.com/reader/full/swisspump-nds-50hz 38/96

   T   e   c   h   n   i   c   a   l

   D   a   t   a

38

NDS 125-80-350 , n=1480RPMHead and power ratings apply to media with a density of ρ=1kg-dm3 and a kinetic viscosity of 20mm2/s.

Page 39: Swisspump Nds 50hz

7/21/2019 Swisspump Nds 50hz

http://slidepdf.com/reader/full/swisspump-nds-50hz 39/9639

NDS 150-100-250 , n=1480RPMHead and power ratings apply to media with a density of ρ=1kg-dm3 and a kinetic viscosity of 20mm2/s.

Page 40: Swisspump Nds 50hz

7/21/2019 Swisspump Nds 50hz

http://slidepdf.com/reader/full/swisspump-nds-50hz 40/96

   T   e   c   h   n   i   c   a   l

   D   a   t   a

40

NDS 150-100-320 , n=1480RPMHead and power ratings apply to media with a density of ρ=1kg-dm3 and a kinetic viscosity of 20mm2/s.

Page 41: Swisspump Nds 50hz

7/21/2019 Swisspump Nds 50hz

http://slidepdf.com/reader/full/swisspump-nds-50hz 41/9641

NDS 150-100-400 , n=1480RPMHead and power ratings apply to media with a density of ρ=1kg-dm3 and a kinetic viscosity of 20mm2/s.

Page 42: Swisspump Nds 50hz

7/21/2019 Swisspump Nds 50hz

http://slidepdf.com/reader/full/swisspump-nds-50hz 42/96

   T   e   c   h   n   i   c   a   l

   D   a   t   a

42

NDS 200-125-240 , n=1480RPMHead and power ratings apply to media with a density of ρ=1kg-dm3 and a kinetic viscosity of 20mm2/s.

Page 43: Swisspump Nds 50hz

7/21/2019 Swisspump Nds 50hz

http://slidepdf.com/reader/full/swisspump-nds-50hz 43/9643

NDS 200-125-300 , n=1480RPMHead and power ratings apply to media with a density of ρ=1kg-dm3 and a kinetic viscosity of 20mm2/s.

Page 44: Swisspump Nds 50hz

7/21/2019 Swisspump Nds 50hz

http://slidepdf.com/reader/full/swisspump-nds-50hz 44/96

   T   e   c   h   n   i   c   a   l

   D   a   t   a

44

NDS 200-125-380 , n=1480RPMHead and power ratings apply to media with a density of ρ=1kg-dm3 and a kinetic viscosity of 20mm2/s.

Page 45: Swisspump Nds 50hz

7/21/2019 Swisspump Nds 50hz

http://slidepdf.com/reader/full/swisspump-nds-50hz 45/9645

NDS 200-125-480 , n=1480RPMHead and power ratings apply to media with a density of ρ=1kg-dm3 and a kinetic viscosity of 20mm2/s.

Page 46: Swisspump Nds 50hz

7/21/2019 Swisspump Nds 50hz

http://slidepdf.com/reader/full/swisspump-nds-50hz 46/96

   T   e   c   h   n   i   c   a   l

   D   a   t   a

46

NDS 200-150-290 , n=1480RPMHead and power ratings apply to media with a density of ρ=1kg-dm3 and a kinetic viscosity of 20mm2/s.

Page 47: Swisspump Nds 50hz

7/21/2019 Swisspump Nds 50hz

http://slidepdf.com/reader/full/swisspump-nds-50hz 47/9647

NDS 200-150-360 , n=1480RPMHead and power ratings apply to media with a density of ρ=1kg-dm3 and a kinetic viscosity of 20mm2/s.

Page 48: Swisspump Nds 50hz

7/21/2019 Swisspump Nds 50hz

http://slidepdf.com/reader/full/swisspump-nds-50hz 48/96

   T   e   c   h   n   i   c   a   l

   D   a   t   a

48

NDS 200-150-460 , n=1480RPMHead and power ratings apply to media with a density of ρ=1kg-dm3 and a kinetic viscosity of 20mm2/s.

Page 49: Swisspump Nds 50hz

7/21/2019 Swisspump Nds 50hz

http://slidepdf.com/reader/full/swisspump-nds-50hz 49/9649

NDS 200-150-570 , n=1480RPMHead and power ratings apply to media with a density of ρ=1kg-dm3 and a kinetic viscosity of 20mm2/s.

Page 50: Swisspump Nds 50hz

7/21/2019 Swisspump Nds 50hz

http://slidepdf.com/reader/full/swisspump-nds-50hz 50/96

   T   e   c   h   n   i   c   a   l

   D   a   t   a

50

NDS 250-200-340 , n=1480RPMHead and power ratings apply to media with a density of ρ=1kg-dm3 and a kinetic viscosity of 20mm2/s.

Page 51: Swisspump Nds 50hz

7/21/2019 Swisspump Nds 50hz

http://slidepdf.com/reader/full/swisspump-nds-50hz 51/9651

NDS 250-200-430 , n=1480RPMHead and power ratings apply to media with a density of ρ=1kg-dm3 and a kinetic viscosity of 20mm2/s.

Page 52: Swisspump Nds 50hz

7/21/2019 Swisspump Nds 50hz

http://slidepdf.com/reader/full/swisspump-nds-50hz 52/96

   T   e   c   h   n   i   c   a   l

   D   a   t   a

52

NDS 250-200-530 , n=1480RPMHead and power ratings apply to media with a density of ρ=1kg-dm3 and a kinetic viscosity of 20mm2/s.

Page 53: Swisspump Nds 50hz

7/21/2019 Swisspump Nds 50hz

http://slidepdf.com/reader/full/swisspump-nds-50hz 53/9653

NDS 250-200-660 , n=1480RPMHead and power ratings apply to media with a density of ρ=1kg-dm3 and a kinetic viscosity of 20mm2/s.

Page 54: Swisspump Nds 50hz

7/21/2019 Swisspump Nds 50hz

http://slidepdf.com/reader/full/swisspump-nds-50hz 54/96

   T   e   c   h   n   i   c   a   l

   D   a   t   a

54

NDS 300-250-270 , n=1480RPMHead and power ratings apply to media with a density of ρ=1kg-dm3 and a kinetic viscosity of 20mm2/s.

Page 55: Swisspump Nds 50hz

7/21/2019 Swisspump Nds 50hz

http://slidepdf.com/reader/full/swisspump-nds-50hz 55/9655

NDS 300-250-280 , n=1480RPMHead and power ratings apply to media with a density of ρ=1kg-dm3 and a kinetic viscosity of 20mm2/s.

Page 56: Swisspump Nds 50hz

7/21/2019 Swisspump Nds 50hz

http://slidepdf.com/reader/full/swisspump-nds-50hz 56/96

   T   e   c   h   n   i   c   a   l

   D   a   t   a

56

NDS 300-250-390 , n=1480RPMHead and power ratings apply to media with a density of ρ=1kg-dm3 and a kinetic viscosity of 20mm2/s.

Page 57: Swisspump Nds 50hz

7/21/2019 Swisspump Nds 50hz

http://slidepdf.com/reader/full/swisspump-nds-50hz 57/9657

NDS 300-250-490 , n=1480RPMHead and power ratings apply to media with a density of ρ=1kg-dm3 and a kinetic viscosity of 20mm2/s.

Page 58: Swisspump Nds 50hz

7/21/2019 Swisspump Nds 50hz

http://slidepdf.com/reader/full/swisspump-nds-50hz 58/96

   T   e   c   h   n   i   c   a   l

   D   a   t   a

58

NDS 300-250-610 , n=1480RPMHead and power ratings apply to media with a density of ρ=1kg-dm3 and a kinetic viscosity of 20mm2/s.

Page 59: Swisspump Nds 50hz

7/21/2019 Swisspump Nds 50hz

http://slidepdf.com/reader/full/swisspump-nds-50hz 59/9659

NDS 300-250-780 , n=1480RPMHead and power ratings apply to media with a density of ρ=1kg-dm3 and a kinetic viscosity of 20mm2/s.

Page 60: Swisspump Nds 50hz

7/21/2019 Swisspump Nds 50hz

http://slidepdf.com/reader/full/swisspump-nds-50hz 60/96

   T   e   c   h   n   i   c   a   l

   D   a   t   a

60

NDS 350-300-310 , n=1480RPMHead and power ratings apply to media with a density of ρ=1kg-dm3 and a kinetic viscosity of 20mm2/s.

Page 61: Swisspump Nds 50hz

7/21/2019 Swisspump Nds 50hz

http://slidepdf.com/reader/full/swisspump-nds-50hz 61/9661

NDS 350-300-330 , n=1480RPMHead and power ratings apply to media with a density of ρ=1kg-dm3 and a kinetic viscosity of 20mm2/s.

Page 62: Swisspump Nds 50hz

7/21/2019 Swisspump Nds 50hz

http://slidepdf.com/reader/full/swisspump-nds-50hz 62/96

   T   e   c   h   n   i   c   a   l

   D   a   t   a

62

NDS 400-300-450L(Low caviation impeller) , n=1480RPMHead and power ratings apply to media with a density of ρ=1kg-dm3 and a kinetic viscosity of 20mm2/s.

Page 63: Swisspump Nds 50hz

7/21/2019 Swisspump Nds 50hz

http://slidepdf.com/reader/full/swisspump-nds-50hz 63/9663

NDS 400-300-450H(High efficiency impeller) , n=1480RPMHead and power ratings apply to media with a density of ρ=1kg-dm3 and a kinetic viscosity of 20mm2/s.

Page 64: Swisspump Nds 50hz

7/21/2019 Swisspump Nds 50hz

http://slidepdf.com/reader/full/swisspump-nds-50hz 64/96

   T   e   c   h   n   i   c   a   l

   D   a   t   a

64

NDS 400-300-570 , n=1480RPMHead and power ratings apply to media with a density of ρ=1kg-dm3 and a kinetic viscosity of 20mm2/s.

Page 65: Swisspump Nds 50hz

7/21/2019 Swisspump Nds 50hz

http://slidepdf.com/reader/full/swisspump-nds-50hz 65/9665

NDS 400-300-700 , n=1480RPMHead and power ratings apply to media with a density of ρ=1kg-dm3 and a kinetic viscosity of 20mm2/s.

Page 66: Swisspump Nds 50hz

7/21/2019 Swisspump Nds 50hz

http://slidepdf.com/reader/full/swisspump-nds-50hz 66/96

   T   e   c   h   n   i   c   a   l

   D   a   t   a

66

NDS 400-350-360 , n=1480RPMHead and power ratings apply to media with a density of ρ=1kg-dm3 and a kinetic viscosity of 20mm2/s.

Page 67: Swisspump Nds 50hz

7/21/2019 Swisspump Nds 50hz

http://slidepdf.com/reader/full/swisspump-nds-50hz 67/9667

NDS 400-350-380 , n=1480RPMHead and power ratings apply to media with a density of ρ=1kg-dm3 and a kinetic viscosity of 20mm2/s.

Page 68: Swisspump Nds 50hz

7/21/2019 Swisspump Nds 50hz

http://slidepdf.com/reader/full/swisspump-nds-50hz 68/96

   T   e   c   h   n   i   c   a   l

   D   a   t   a

68

NDS 400-350-520 , n=1480RPMHead and power ratings apply to media with a density of ρ=1kg-dm3 and a kinetic viscosity of 20mm2/s.

Page 69: Swisspump Nds 50hz

7/21/2019 Swisspump Nds 50hz

http://slidepdf.com/reader/full/swisspump-nds-50hz 69/9669

NDS 450-450-350 , n=1480RPMHead and power ratings apply to media with a density of ρ=1kg-dm3 and a kinetic viscosity of 20mm2/s.

Page 70: Swisspump Nds 50hz

7/21/2019 Swisspump Nds 50hz

http://slidepdf.com/reader/full/swisspump-nds-50hz 70/96

   T   e   c   h   n   i   c   a   l

   D   a   t   a

70

NDS 500-300-780 , n=1480RPMHead and power ratings apply to media with a density of ρ=1kg-dm3 and a kinetic viscosity of 20mm2/s.

Page 71: Swisspump Nds 50hz

7/21/2019 Swisspump Nds 50hz

http://slidepdf.com/reader/full/swisspump-nds-50hz 71/9671

NDS 500-400-420 , n=1480RPMHead and power ratings apply to media with a density of ρ=1kg-dm3 and a kinetic viscosity of 20mm2/s.

Page 72: Swisspump Nds 50hz

7/21/2019 Swisspump Nds 50hz

http://slidepdf.com/reader/full/swisspump-nds-50hz 72/96

   T   e   c   h   n   i   c   a   l

   D   a   t   a

72

NDS 500-400-540 , n=1480RPMHead and power ratings apply to media with a density of ρ=1kg-dm3 and a kinetic viscosity of 20mm2/s.

Page 73: Swisspump Nds 50hz

7/21/2019 Swisspump Nds 50hz

http://slidepdf.com/reader/full/swisspump-nds-50hz 73/9673

NDS 500-400-660 , n=1480RPMHead and power ratings apply to media with a density of ρ=1kg-dm3 and a kinetic viscosity of 20mm2/s.

Page 74: Swisspump Nds 50hz

7/21/2019 Swisspump Nds 50hz

http://slidepdf.com/reader/full/swisspump-nds-50hz 74/96

   T   e   c   h   n   i   c   a   l

   D   a   t   a

74

NDS 400-350-540 , n=980RPMHead and power ratings apply to media with a density of ρ=1kg-dm3 and a kinetic viscosity of 20mm2/s.

Page 75: Swisspump Nds 50hz

7/21/2019 Swisspump Nds 50hz

http://slidepdf.com/reader/full/swisspump-nds-50hz 75/9675

NDS 500-300-920 , n=980RPMHead and power ratings apply to media with a density of ρ=1kg-dm3 and a kinetic viscosity of 20mm2/s.

Page 76: Swisspump Nds 50hz

7/21/2019 Swisspump Nds 50hz

http://slidepdf.com/reader/full/swisspump-nds-50hz 76/96

   T   e   c   h   n   i   c   a   l

   D   a   t   a

76

NDS 500-400-400 , n=980RPMHead and power ratings apply to media with a density of ρ=1kg-dm3 and a kinetic viscosity of 20mm2/s.

Page 77: Swisspump Nds 50hz

7/21/2019 Swisspump Nds 50hz

http://slidepdf.com/reader/full/swisspump-nds-50hz 77/9677

NDS 500-400-420 , n=980RPMHead and power ratings apply to media with a density of ρ=1kg-dm3 and a kinetic viscosity of 20mm2/s.

Page 78: Swisspump Nds 50hz

7/21/2019 Swisspump Nds 50hz

http://slidepdf.com/reader/full/swisspump-nds-50hz 78/96

   T   e   c   h   n   i   c   a   l

   D   a   t   a

78

NDS 500-400-570 , n=980RPMHead and power ratings apply to media with a density of ρ=1kg-dm3 and a kinetic viscosity of 20mm2/s.

Page 79: Swisspump Nds 50hz

7/21/2019 Swisspump Nds 50hz

http://slidepdf.com/reader/full/swisspump-nds-50hz 79/9679

NDS 500-400-675 , n=980RPMHead and power ratings apply to media with a density of ρ=1kg-dm3 and a kinetic viscosity of 20mm2/s.

Page 80: Swisspump Nds 50hz

7/21/2019 Swisspump Nds 50hz

http://slidepdf.com/reader/full/swisspump-nds-50hz 80/96

   T   e   c   h   n   i   c   a   l

   D   a   t   a

80

NDS 600-400-740 , n=980RPMHead and power ratings apply to media with a density of ρ=1kg-dm3 and a kinetic viscosity of 20mm2/s.

Page 81: Swisspump Nds 50hz

7/21/2019 Swisspump Nds 50hz

http://slidepdf.com/reader/full/swisspump-nds-50hz 81/9681

NDS 600-400-850 , n=980RPMHead and power ratings apply to media with a density of ρ=1kg-dm3 and a kinetic viscosity of 20mm2/s.

Page 82: Swisspump Nds 50hz

7/21/2019 Swisspump Nds 50hz

http://slidepdf.com/reader/full/swisspump-nds-50hz 82/96

   T   e   c   h   n   i   c   a   l

   D   a   t   a

82

NDS 600-500-520 , n=980RPMHead and power ratings apply to media with a density of ρ=1kg-dm3 and a kinetic viscosity of 20mm2/s.

Page 83: Swisspump Nds 50hz

7/21/2019 Swisspump Nds 50hz

http://slidepdf.com/reader/full/swisspump-nds-50hz 83/9683

NDS 600-500-550 , n=980RPMHead and power ratings apply to media with a density of ρ=1kg-dm3 and a kinetic viscosity of 20mm2/s.

Page 84: Swisspump Nds 50hz

7/21/2019 Swisspump Nds 50hz

http://slidepdf.com/reader/full/swisspump-nds-50hz 84/96

   T   e   c   h   n   i   c   a   l

   D   a   t   a

84

NDS 600-500-580 , n=980RPMHead and power ratings apply to media with a density of ρ=1kg-dm3 and a kinetic viscosity of 20mm2/s.

Page 85: Swisspump Nds 50hz

7/21/2019 Swisspump Nds 50hz

http://slidepdf.com/reader/full/swisspump-nds-50hz 85/9685

NDS 600-450-640 , n=980RPMHead and power ratings apply to media with a density of ρ=1kg-dm3 and a kinetic viscosity of 20mm2/s.

Page 86: Swisspump Nds 50hz

7/21/2019 Swisspump Nds 50hz

http://slidepdf.com/reader/full/swisspump-nds-50hz 86/96

   T   e   c   h   n   i   c   a   l

   D   a   t   a

86

NDS 700-500-670 , n=980RPMHead and power ratings apply to media with a density of ρ=1kg-dm3 and a kinetic viscosity of 20mm2/s.

Page 87: Swisspump Nds 50hz

7/21/2019 Swisspump Nds 50hz

http://slidepdf.com/reader/full/swisspump-nds-50hz 87/9687

NDS 700-500-940 , n=980RPMHead and power ratings apply to media with a density of ρ=1kg-dm3 and a kinetic viscosity of 20mm2/s.

Page 88: Swisspump Nds 50hz

7/21/2019 Swisspump Nds 50hz

http://slidepdf.com/reader/full/swisspump-nds-50hz 88/96

   T   e   c   h   n   i   c   a   l

   D   a   t   a

88

NDS 700-600-600 , n=980RPMHead and power ratings apply to media with a density of ρ=1kg-dm3 and a kinetic viscosity of 20mm2/s.

Page 89: Swisspump Nds 50hz

7/21/2019 Swisspump Nds 50hz

http://slidepdf.com/reader/full/swisspump-nds-50hz 89/9689

NDS 700-600-740 , n=980RPMHead and power ratings apply to media with a density of ρ=1kg-dm3 and a kinetic viscosity of 20mm2/s.

Page 90: Swisspump Nds 50hz

7/21/2019 Swisspump Nds 50hz

http://slidepdf.com/reader/full/swisspump-nds-50hz 90/96

   T   e   c   h   n   i   c   a   l

   D   a   t   a

90

NDS 600-500-550 , n=740RPMHead and power ratings apply to media with a density of ρ=1kg-dm3 and a kinetic viscosity of 20mm2/s.

Page 91: Swisspump Nds 50hz

7/21/2019 Swisspump Nds 50hz

http://slidepdf.com/reader/full/swisspump-nds-50hz 91/9691

NDS 600-500-580 , n=740RPMHead and power ratings apply to media with a density of ρ=1kg-dm3 and a kinetic viscosity of 20mm2/s.

Page 92: Swisspump Nds 50hz

7/21/2019 Swisspump Nds 50hz

http://slidepdf.com/reader/full/swisspump-nds-50hz 92/96

   T   e   c   h   n   i   c   a   l

   D   a   t   a

92

NDS 700-600-680 , n=740RPMHead and power ratings apply to media with a density of ρ=1kg-dm3 and a kinetic viscosity of 20mm2/s.

Page 93: Swisspump Nds 50hz

7/21/2019 Swisspump Nds 50hz

http://slidepdf.com/reader/full/swisspump-nds-50hz 93/9693

NDS 800-700-750 , n=740RPMHead and power ratings apply to media with a density of ρ=1kg-dm3 and a kinetic viscosity of 20mm2/s.

Page 94: Swisspump Nds 50hz

7/21/2019 Swisspump Nds 50hz

http://slidepdf.com/reader/full/swisspump-nds-50hz 94/96

Page 95: Swisspump Nds 50hz

7/21/2019 Swisspump Nds 50hz

http://slidepdf.com/reader/full/swisspump-nds-50hz 95/96

Page 96: Swisspump Nds 50hz

7/21/2019 Swisspump Nds 50hz

http://slidepdf.com/reader/full/swisspump-nds-50hz 96/96