swimming pool / hot tub installation - central boiler · 2020-05-19 · swimming pool/ hot tub...

1
To Home or Other Building To Pool or C - 320 May 2020 ©2020 Central Boiler Swimming Pool/ Hot Tub Installation CENTRAL PEX From Pool or Hot Tub Pump Heated Water To Pool Or Hot Tub Hot Supply From Outdoor Wood Furnace Unit Bypass Temperature Gauge CENTRAL PEX PVC or ABS Pipe & Fittings These Valves Must Be Closed When "Shocking" Your Pool Adjust Flow From Pool Pump Return Main W R White Black C R 110-V Power Source 24-V Transformer End Switch Motor Circuit LED C W/Y C W Shell & Tube White Black 110-V Power Source 24-V Transformer End Switch Motor Circuit LED C W/Y C W Plate Exchanger C R W R Water from Pool or Hot Tub Filter Heated Water to Pool or Hot Tub Unit (A) Main PVC or ABS Pipe and Accessories These valves must be closed when "shocking" your pool. Adjust bypass flow from pool pump. CENTRAL PEX 3-Way Zone Valve Main Unit (A) Bypass (B) Hot Supply from Pump on Outdoor Furnace Valve ) Pool Aquastat (with Well)

Upload: others

Post on 13-Jun-2020

1 views

Category:

Documents


0 download

TRANSCRIPT

Page 1: Swimming Pool / Hot Tub Installation - Central Boiler · 2020-05-19 · Swimming Pool/ Hot Tub Installation CENTRAL PEX From Pool or Hot Tub Pump Heated Water To Pool Or Hot Tub Hot

To Home or Other Building

To Pool or

C - 320May 2020 ©2020 Central Boiler

Swimming Pool/Hot Tub Installation

CENTRAL PEX

From Pool orHot Tub Pump

HeatedWater To PoolOr Hot Tub

Hot Supply FromOutdoor Wood

Furnace

UnitBypass

TemperatureGauge

CENTRAL PEX

PVC or ABSPipe & Fittings

These Valves Must Be Closed When

"Shocking" Your Pool

Adjust Flow From Pool

Pump

Return

Main

W

R

White Black

C

R

110-VPower Source

24-V Transformer

End Switch

MotorCircuit

LEDC

W/Y

C

W

Shell & Tube

White Black

110-VPower Source

24-VTransformer

End Switch

MotorCircuit

LEDC

W/Y

C

W

Plate Exchanger

C

R

W

R

Water fromPool or HotTub Filter

HeatedWater to Pool

or Hot Tub

Unit (A)

MainPVC or ABS

Pipe and Accessories

These valves mustbe closed when

"shocking" your pool.

Adjust bypass�ow from

pool pump.

CENTRAL PEX

Black

C

R

110-VPower Source

24-VTransformer

Water fromPool or HotTub Filter

HeatedWater to Pool

or Hot Tub

Adjust bypass�ow from

pool pump.

3-Way Zone Valve

Main

Unit (A)

Bypass (B)

PVC or ABSPipe and Accessories

These valves mustbe closed when

"shocking" your pool.

Hot Supply from Pumpon Outdoor Furnace

Return to Outdoor Furnace

Thermostatic Valve(optional)

PoolAquastat(with Well)