swash-plate type axial piston pumps for open circuits in ... · pdf filefor open circuits in...

15
Swash-plate Type Axial Piston Pumps for Open Circuits in Industrial Vehicles

Upload: dinhnga

Post on 30-Jan-2018

220 views

Category:

Documents


1 download

TRANSCRIPT

Page 1: Swash-plate Type Axial Piston Pumps for Open Circuits in ... · PDF filefor Open Circuits in Industrial Vehicles. ... Double pump (Parallel type) DT: Double pump (Tandem type) S :

Swash-plate Type Axial Piston Pumpsfor Open Circuits in Industrial Vehicles

Page 2: Swash-plate Type Axial Piston Pumps for Open Circuits in ... · PDF filefor Open Circuits in Industrial Vehicles. ... Double pump (Parallel type) DT: Double pump (Tandem type) S :

ON APPLICATION / USAGE OF THE PRODUCTS

The operating conditions of the products shown in this catalog vary depending upon each application. Therefore, the decision of the products' suitability to the system considered must be made by the designer of the hydraulic system and/or the person in charge of determining the specification after making analysis and conducting tests, if necessary. The study of the specification shall be done based on the latest catalog and technical documents, and the system must be composed taking into account situations regarding the possibility of machine failure.

Prior to use of the products, descriptions given in the SAFETY PRECAUTIONS must be observed for the proper use.

The technical information in this catalog represents typical characteristics and performance of the products, and is not guaranteed one.

In case the products are used in the following conditions or environments, please consult us prior to the use.

Unspecified conditions or environmentsUse for atomic power, aviation, medical treatment, and/or foodUse likely to affect human beings or assets significantly or requiring particular safety

The information described in this catalog is subject to change without notice.For updated information, please consult our campany.

Although our products are designed on the basis of our profound knowledgeand long experience, and manufactured under the strict quality control system,the following must be taken into consideration in actual use.

1

Page 3: Swash-plate Type Axial Piston Pumps for Open Circuits in ... · PDF filefor Open Circuits in Industrial Vehicles. ... Double pump (Parallel type) DT: Double pump (Tandem type) S :

SAFETY PRECAUTIONSBefore you use the product, you MUST read the operation or operators manual and MUST fully understand how to use the product.

To use the product safely, you MUST carefully read all Warnings and Cautions in this manual. You MUST also observe the related regulations and rules regarding safety.

Installation, removal, plumbing, and wiring must be done by the certified person.

*CERTIFIED PERSON: a person who has enough knowledge like a person who is trained by Kawasaki’s hydraulic school.

Make it sure that the power of the hydraulic power unit is turned off and that the electric motor or engine has completely stopped before starting installation or removal. You must also check the system pressure has dropped to zero.

CAUTION

WARNING

Turn off the power before starting wiring or other works related to the electric power, otherwise you may be stuck by an electric shock.

Use the specified bolts and keep the specified tightening torque when you install the product. Usage of unauthorized bolts, lack of torque or excess of torque may create problems such as failure of work, damage and oil leakage.

Clean the threads and mounting surface completely, otherwise you may experience damages or oil leakage caused by insufficient tightening torque or broken seal.

WARNING

CAUTION

CAUTION

Use the product under the specification mentioned in the catalog, drawings and specification sheet.

Keep your body off the product during the operations as it may become hot and burn your body.

Use the proper hydraulic oil, and maintain the contamination in the recommended level, otherwise it may not work or be damaged.

CAUTION

CAUTION

CAUTION

Use the safety equipment to avoid the injury when you operate the product.

Pay enough attention on handling method to avoid pinching hands or back problems that may be caused by heavy weight of the product or handling posture.

Do not step on the product, hit it, drop it or give strong outside force to it, as one of these actions may cause the failure of work, damage or oil leakage.

Wipe the oil on the product or floor off completely, as the oil creates slippery conditions that may result in dropping the product or injuring.

CAUTION

CAUTION

CAUTION

CAUTION

Cautions related to operation

Never use the product not equipped with anti-explosion protection in the circumstances of possible explosion or combustion.

Shield the rotating part such as motor shaft and pump shaft to avoid injuries caused by being caught of fingers or cloths.

Stop the operation immediately if you find something wrong such as unusual noise, oil leakage or smoke, and fix it properly. If you continue operating, you may encounter damage, fire or injury.

Make it sure that plumbing and wiring are correct and all the connection is tightened correctly before you start operating, especially if it is the first run.

DANGER

WARNING

WARNING

CAUTION

Warnings and Cautions for operation

Warnings and Cautions related to installation and removal of the product

Never modify the product without approval of Kawasaki.

Do not disassemble and assemble without approval by Kawasaki. It may cause troubles and failure, or it may not work as specified. If it is necessary by all means to disassemble and assemble, it must be done by an authorized person.

Keep the product from dust and rust by paying attention to the surrounding temperature and humidity when you transport or store the product.

Replacing the seals may be required if you use the product after long time storage.

Cautions related to maintenance

CAUTION

CAUTION

CAUTION

CAUTION

2

Page 4: Swash-plate Type Axial Piston Pumps for Open Circuits in ... · PDF filefor Open Circuits in Industrial Vehicles. ... Double pump (Parallel type) DT: Double pump (Tandem type) S :

– 60 cm3

– 80

– 110

– 140

– 200

– 280

Displacement Double pump(Tandem type)

Double pump (Parallel type) Single pump

•K3V63DT•K5V80DT

•K3V63DTP•K5V80DTP

•K3V112DT•K5V140DT

•K3V112DTP•K5V140DTP

•K3V140DT •K3V140DTP

•K5V200DT •K5V200DTP

•K5V200DTH

•K3V280DTH

•K3V112DP•K5V140DP

•K3V63S•K5V80S

•K3V112S•K5V140S

•K3V140S

•K5V200S•K5V200DP

•K5V200DPH •K5V200SH

•K3V280S

•K3V280SH

KPM Swash Plate Type Axial Piston Pumps Programs for Industrial Vehicles

Out of a Wide Variety of Our Swash Plate Type Axial Piston Pumps,We Introduce below Those Most Suitable for Construction Machines with Open Circuits.

3

Page 5: Swash-plate Type Axial Piston Pumps for Open Circuits in ... · PDF filefor Open Circuits in Industrial Vehicles. ... Double pump (Parallel type) DT: Double pump (Tandem type) S :

A Thorough Function Desigh Enabled Such Atractive Features

3. Long LifeA long life is obtained by adopting main bearings of large capacity and the piston-return mechanism that compensates for the wear of the shoe.

4. Low NoiseEven less noise has been achieved because of the op-timum design of the valve plate and the casing rigidity.

5. Wide Range of ControlsThe pump can be controlled in various kinds of control methods and is capable of responding to either mech-anical, hydraulic or electrical input.

1. High Power DensityA lighter and more compact machine with higher pres-sure rating and increased power density (output pow-er/mass) was obtained by adopting a half log type swash plate.

In particular, the double pump with its tandem ar-rangement, has eliminated a power divider, has an in-creased transmission efficiency, and is lighter.

2. High Efficiencyand Large Self-Priming Capability

The spherical valve plate and improved hydraulic bal-ance provide stable cylinder rotation, thus achieving high efficiency even in a low-pressure and low-speed operating range.

4

Page 6: Swash-plate Type Axial Piston Pumps for Open Circuits in ... · PDF filefor Open Circuits in Industrial Vehicles. ... Double pump (Parallel type) DT: Double pump (Tandem type) S :

SERIES

The N series pump, which was used widely as a piston pump especially for construction machines, has been modified to the K3V series, meeting the present-day requirements. This pump has optimum functuon design and is provided with further improved power density, efficiency, and reliability, attained from our many years of experiences with the NV series.

K3V series

63: 63cm3

112: 112cm3

140: 140cm3

280: 280cm3

Displacement

Design code of regulator

Regulator code

DP: Double pump (Parallel type)

DT: Double pump (Tandem type)

S : Single pump

Desigh code

Standardwith Centrifugal pumpH :with PTOP :

R :L :

Direction of rotationClockwiseCounterclockwise(viewed from shaft end)

ORDERING CODE

SPECIFICATIONS

K3V 280 DT H 100 R 2N 01

1MPa = 10.197kgf/cm2

1N·m = 0.10197kgf·m1.Pressure to which guarantee of

performance, functions or ser-vice life is applied. Durability is unlimited (except for the bear-ing life).

2.At max. displacement. In case of engine driving, max. idling speed should be below this val-ue. This suction pressure should be -0.01 MPa and above.

3.Suction pressure should be above 0.1MPa.

4.Max. speed with centrifugal pump

5.When other kinds of fluid would be used, please consult with us.

Size

81 125

28063 112 140

2,650 2,360 2,150

2,0003,250 2,700 2,500

294125

343 1,950588 1,120

34.3

39.2

63 112 140 280

270160

140866848

Pressure(MPa)

Speed(min-1)

Displacement

Mass(kg)

Single

Tandem

Type

10 ~ 1,000 mm2/S (cSt)

80 ~ 150 mesh

Rated

Max.

Peak

Max. input torque of tandem pump

Oil temperature range

Max. for self priming

Oil viscosity range

FiltrationSuction line

Return line nominal 10 micron meter

(N·m)

Max. input torque of attached gear pump with PTO (N·m)

Hydraulicfluid

1

2

3

Antiwear hydraulic fluid5

1,600(2,000)

4

-20 ~ +95 °C

(cm3)

5

Page 7: Swash-plate Type Axial Piston Pumps for Open Circuits in ... · PDF filefor Open Circuits in Industrial Vehicles. ... Double pump (Parallel type) DT: Double pump (Tandem type) S :

K5V series

80: 80cm3

140: 140cm3

200: 200cm3

Displacement

DP: Double pump (Parallel type)

DT: Double pump (Tandem type)

S : Single pump

Standardwith Centrifugal pumpH :with PTOP :

SERIES

With new technology the K5V series has enabled increased power density.

Desigh code

Design code of regulator

Regulator code

Direction of rotationClockwiseCounterclockwise(viewed from shaft end)

•Variation of pump displacement

K3V

K5V

Displacement (cm3)

500 100 150 200 300250

ORDERING CODE

SPECIFICATIONS1.Pressure to which guarantee of

performance, functions or ser-vice life is applied. Durability is unlimited (except for the bear-ing life).

2.At max. displacement. In case of engine driving, max. idling speed should be below this val-ue. This suction pressure should be -0.0 1MPa and above.

3.Suction pressure should be above 0.1MPa.

4.Max. speed with centrifugal pump

5.When other kinds of fluid would be used, please consult with us.

K5V 200 DT H 100 R 9N 01

1MPa = 10.197kgf/cm2

1N·m = 0.10197kgf·m

K5V80 K5V140 K5V200

63 112 140 180 280

Size

81 125

20080 140

2,460 2,160

2,2003,000 2,500

125

529 1,120843

34.3

39.2

80 140 200

160

86

294

6848

Pressure(MPa)

Speed(min-1)

Displacement

Mass(kg)

Single

Tandem

Type

10 ~ 1,000 mm2/S (cSt)

80 ~ 150 mesh

Rated

Max.

Peak

Max. input torque of tandem pump

Oil temperature range

Max. for self priming

Oil viscosity range

FiltrationSuction line

Return line nominal 10 micron meter

(N·m)

Max. input torque of attached gear pump with PTO (N·m)

Hydraulicfluid

1

2

3

Antiwear hydraulic fluid5

1,900(2,200)

4

-20 ~ +95 °C

(cm3)

6

Page 8: Swash-plate Type Axial Piston Pumps for Open Circuits in ... · PDF filefor Open Circuits in Industrial Vehicles. ... Double pump (Parallel type) DT: Double pump (Tandem type) S :

Q

P

Q

S

Q

Pi

Q

Pi

Q

P

Q

I

Q

Pi

Pm

Q

P

Q

P

Q

P

Q

P1

P2

Pf

P2

Pi1

P2

Q

P

P2P2

Pf

PL

PA

Pi1

Pi1

Pm1

P2 P2

Pi1

P2

Pf

•Flow Control

Flow cotrol and Horsepower control can be combined with each other.Examples of applied circuits are shown above.Please consult us about other kinds of control, if necessary.

Code

Code No.

1

2

4

5

6

9

10 20 60 2P 2N 9L 2C 9N

Control type

Constanthorsepowercontrol

Totalhorsepowercontrol

High pressurecut-off

Variablehorsepowercontrol

Control typeConstant horsepowercontrol

Total horsepowercontrol

Total horsepower control +High-pressure cut-off

Positive flow control +Total horsepower control

Negative flow control +Total horsepower control

Load sensing control +Total horsepower control +Variable horsepower control

Negative flow control +Total horsepower control +Two-stage max. flow control

Negative flow control +Total horsepower control +Variable horsepower control

Circuit diagram

Control curve

P2:Companion pumppressure

Pressure cut-off

Horsepower control+ Pressure cut-off

Totalhorsepower control+ Pressure cut-off

Function & features

According to the rise of delivery pressuer of a pump, the tilting angle of the pump is automatically decreased, and the constant torque control is achieved.

If the pressure rises above the set value, the pump outlet flow is automatically decreased by the pressure cut-off control.

Variable horsepower control can be obtained by supplying pilot pressure or electric current.

1.According to the rise of delivery pressure of a pump, the tilting angle of the pump is automatically decreased, and the constant torque control is achieved. (compensation control)

2.The total horsepower control can be achieved by decreasing the horsepower of a pump depending upon the pressure of its companion pump.

Code

M

P

N

C

L

E

Control type

Manual flow control

Lever stroke

Electric current

P = PA- PL

PA: Pump pressure PL: Load pressure

Pilot pressure

Positive flow control

Negative flow control

2-stage max. flowcontrol

Load sensing control

Electric flow control

Control curve Function & features

With the manual control, the outlet flow can be step-lessly controlled.

Positive flow control can be carried out by using the pilot pressure.

Negative flow control can be carried out by using the pilot pressure.

Two-stage max. flow control can be obtained by sup-plying external pilot pressure.(only in negative flow control)

Load sensing control can be obtained.

With the electric current, the oulet flow can be controlled.

•Horsepower Control

SUMMARY OF REGULATORS

7 8

Page 9: Swash-plate Type Axial Piston Pumps for Open Circuits in ... · PDF filefor Open Circuits in Industrial Vehicles. ... Double pump (Parallel type) DT: Double pump (Tandem type) S :

L2

L1

L3

L10

L9L8

L12

L11

L13

L14

L15

D2

Direction of rotation

: Clockwise: Counterclockwise(Viewed from shaft end)

Dr2

Dr1

Flange mounting face

30°

D1

L5

L6L7

L15

L16

Suction

Delivery

L22

L21 MInvolute splineto SAE

D3

L23

L17L13

Dr2

Dr2

Dr1

L12

L11D

2

4- d

30 °

D1

L5

L6L7

L4

L1 L19

L18

L20

L2

L9L8

L10

Flange mounting face Flange mounting face

Dr1

Use Dr1 or Dr2 port for case drain.

DIMENSIONS

•Tandem Type

L4

4- d

Dr2

Dr1

•Tandem Type (with PTO)

Use Dr1 or Dr2 port for case drain.

Dimensions of PTO unit

Suction

Delivery

SAE

30°

16/32

Flat root

Side fit

1310

Rule

Type of fit

Pressure angle

Diametral pitchCutter

Root form

Number of teeth

•Involute spline to SAE

Suction

Delivery

9

Page 10: Swash-plate Type Axial Piston Pumps for Open Circuits in ... · PDF filefor Open Circuits in Industrial Vehicles. ... Double pump (Parallel type) DT: Double pump (Tandem type) S :

Size D1 D2 D3 L1 L2 L3 L6L5L4 L9L8 L10 L11 L12 L13 L14 L15L7d

K3V63K3V112K3V140K3V280K5V80K5V140K5V200

180224250300180224250

125160180200125160180

18222226182222

767893

115767893

708092

150708092

708092

125708092

142142142142142142142

190234256300190234256

228265305356228265305

138167190203138167190

464538618792464538618

195220245286195220245

9710912115097

109121

8910011212789

100112

9811012314098

110123

37415370374153

37415370374153

8888888

82.5582.55101.6

82.5582.55101.6

Size a

K3V63K3V112K3V140K3V280K5V80K5V140K5V200

G 1/2G 3/4G 3/4G 3/4G 1/2G 3/4G 3/4

b

22.630.830.830.822.630.830.8

c

a

b

e

b

b

a

d d

a

c

c c

d

a

L9

L9

cd

2.53.53.53.52.53.53.5

d

19202323192023

(mm)

Size

K3V63K3V112K3V140K5V80K5V140K5V200

L16

110110122110110122

L17

213213292213213292

L19

268305361268305361

L20

150150200150150200

L21

2.42.42.42.42.42.4

L22

88

1588

15

L23

106106127106106127

L18

177214257177214257

(mm)

Size No. of teethSpec. Pitch circle dia(mm) RuleModulePressure angle

(mm)

Size a

K3V63K3V112K3V140K3V280K5V80K5V140K5V200

b

23.823.827.831.823.823.827.8

50.850.857.266.750.850.857.2

31.031.037.561.531.031.037.5

M10—16M10—16M12—22M12—20M10—16M10—16M12—22

19192532191925

c d(mm)

d—Screw depth

e—Screw depth

Size a

K3V63K3V112K3V140K3V280K5V80K5V140K5V200

b

50.850.861.969.850.850.861.9

88.988.9

106.4120.788.988.9

106.4

M12—18M12—18M16—24M16—24M12—18M12—18M16—24

M

2—M10—252—M10—254—M12—222—M10—252—M10—254—M12—22

60607689606076

c

K3V63K3V112K3V140K3V280K5V80K5V140K5V200

14141718121717

30°20°20°20°20°20°20°

29.635.042.554.030.042.542.5

SAEJIS B 1603JIS B 1603JIS B 1603JIS B 1603JIS B 1603JIS B 1603

12/242.52.53.02.52.52.5

(mm)

15°

45°

•Dimensions

•Dimensions of shaft end

•Flange mounting face for Suction port (SAE Rule)

•Flange mounting face for Delivery port (SAE Rule)

•Drain port (Rule: JIS B 2351)

10

Page 11: Swash-plate Type Axial Piston Pumps for Open Circuits in ... · PDF filefor Open Circuits in Industrial Vehicles. ... Double pump (Parallel type) DT: Double pump (Tandem type) S :

b

a

d d

a

c c

e

Delivery

Suction

L7

L11

L10 Dr1

L9

L5L4

L1L2

L12

L13

L3

L6L8

D2

15°

30°

D1

12 dDirection of rotation: Clockwise

K3V112K5V140K5V200

429429530

410410511

111114

235235272

113113138

163163206

111111141

256256301

555

391391400

148148135

522522625

428428507

493493570

385385398

343434

a

b

b

c

d

a

cd

a

K3V112K5V140K5V200

K3V112K5V140K5V200

G 3/4G 3/4G 3/4

b

30.830.830.8

c

3.53.53.5

d

202023

(mm)

a b

23.823.831.8

50.850.866.7

34.034.041.5

M10—16M10—16M12—22

191932

c d(mm)

K3V112K5V140K5V200

a b

50.850.869.9

88.988.9

120.7

M12—18M12—18M16—24

606083

c(mm)

15˚

45˚

Size No. of teethSpec. Pitch circle dia(mm) RuleModulePressure angle

K3V112K5V140K5V200

141715

20°20°30°

35.042.547.6

JIS B 1603JIS B 1603

ANSI

2.52.5

8/16

L9L8 L10 L11 L12 L13L2 L3 L6L5L4 L7Size

Size

Size

Size

D1 D2 L1d(mm)

DIMENSIONS

•Parallel Type

(Viewed from shaft end)

Use Dr1 port for case drain.

•Dimensions

•Flange mounting face for Delivery port (SAE Rule)

•Drain port (Rule: JIS B 2351)

•Flange mounting face for Suction port (SAE Rule)

•Dimensions of shaft end

e—Screw depth

d—Screw depth

11

Page 12: Swash-plate Type Axial Piston Pumps for Open Circuits in ... · PDF filefor Open Circuits in Industrial Vehicles. ... Double pump (Parallel type) DT: Double pump (Tandem type) S :

Suction

Delivery

Flange mounting face

4- d

4- d

D1

30°

L7L6

L5

D2

L10

L9L8

L12

L11

L13

L4

L4

L5

L16L6

L1

L7

L16

Suction

Delivery

Dr1

Dr2

L2

L15

L14

L3

Dr2

Dr1

Use Dr1 or Dr2 port for case drain.

Size D1 D2 L1 L2 L3 L6L5L4 L9L8 L10 L11 L12 L13 L15 L16L7d

K3V63K3V112K3V140K3V280K5V80K5V140K5V200

180224250300180224

125160180200125160165

18222222182222

767893

115767875

708092

150709292

708092

125709292

142142142142142142142

190234256300190234265

210250292343210264300

138167190203138167190

277309366433277338389

195220245286195220245

L14

8910912113589

109121

8910011212789

100132

9811012314098

110132

37415370374153

37415370374153

888888

16

a

b

b

c

d

a

L9

cd

(mm)

Size No. of teethSpec. Pitch circle dia(mm) RuleModulePressure angle

a

K3V63K3V112K3V140K3V280K5V80K5V140K5V200

G 1/2G 3/4G 3/4G 3/4G 1/2G 3/4G 3/4

b

22.630.830.830.822.630.830.8

c

2.53.53.53.52.53.53.5

d

19202323192023

(mm)Size

Size

K3V63K3V112K3V140K3V280K5V80K5V140K5V200

27.823.831.831.827.831.836.5

57.250.866.766.757.266.779.4

25193232253238

(mm)

M12—16M10—16M12—18M12—20M12—16M12—18M16—24

K3V63K3V112K3V140K3V280K5V80K5V140K5V200

14141718121713

30°20°20°20°20°20°30°

29.635.042.554.030.042.541.3

SAEJIS B 1603JIS B 1603JIS B 1603JIS B 1603JIS B 1603

SAE

12/242.52.53.02.52.5

8/16

15°

45°

225

b

c

d

a

L9

K3V63K3V112K3V140K3V280K5V80K5V140K5V200

a

35.730.250.869.935.750.861.9

b

69.958.788.9

120.769.988.9

106.4

38386080386076

c(mm)

M12—18M12—18M12—18M12—20M12—18M12—18M16—24

•Single Type

d—Screw depth d—Screw depthSize a b c

•Dimensions

•Flange mounting face for Delivery port (SAE Rule)

•Dimensions of shaft end

•Flange mounting face for Suction port (SAE Rule)

•Drain port (Rule: JIS B 2351)

Direction of rotation

: Clockwise: Counterclockwise(Viewed from shaft end)

for K5V200S

12

Page 13: Swash-plate Type Axial Piston Pumps for Open Circuits in ... · PDF filefor Open Circuits in Industrial Vehicles. ... Double pump (Parallel type) DT: Double pump (Tandem type) S :

CAUTION FOR INSTRUCTION

Mounting Direction and Drain Piping

The upper drain port should be used, and the drain pipe size must be equal to or larger than the drain port size.In case of the pumps with centrifugal pump, the drain lines must be settled on each pump.

The pump shaft should be mounted in the horizontal direction as shown in the figure below.The drain line loop must be extended above the top of the pump case.

For satisfactory service life of these pumps in application, the operating fluid should be continuously fiitered to keep at least the cleanliness level of NAS 1638 Class 9.A 10 µm filter must be used in the return line and a 80 ~ 150 mesh strainer in the suction lines.

Filtration

Front pump

Tandem pump

Rear pump

Examples of using a filter

150 mesh 150 mesh

Air

10 µm 10 µm

13

Page 14: Swash-plate Type Axial Piston Pumps for Open Circuits in ... · PDF filefor Open Circuits in Industrial Vehicles. ... Double pump (Parallel type) DT: Double pump (Tandem type) S :

P

0.1 sec

0.4MPa (peak)

0.1MPa (normal)

Connection of Driving Shaft

Please use a flexible coupling for connection of the pump drive shaft with an engine flywheel or an electric motor shaft.Alignment should be so carried out that the parallel error may be held with in ± 0.03 mm.Do not put a radial or thrust load at the shaft end.

Starting

Before starting-up, fill the pump case with system fluid through the case drain connection. Case must remain full of fluid to provide internal lubrication.

Case Drain pressure

Please be careful so that the drain pressure in the casing does not exceed 0.1 MPa normally and 0.4 MPa at its peak.A suitable size of drain hose and drain filter should be selected.

14

Page 15: Swash-plate Type Axial Piston Pumps for Open Circuits in ... · PDF filefor Open Circuits in Industrial Vehicles. ... Double pump (Parallel type) DT: Double pump (Tandem type) S :

KK HYDRAULICS SALES (SHANGHAI) LTD.B-908 Far East International Plaza 317 Xianxia Rd, Shanghai 200051Phone: 86-21-62351606 Fax: 86-21-62957080

Flutek, Ltd.192-11, Shinchon-dong, Changwon, Kyungnam, 641-370 Korea Phone: 82-55-286-5551 Fax: 82-55-286-5553

•Materials and specifications are subject to change without manufacturer's obligation.

Head Office / Main Plant234, Matsumoto, Hasetani-cho, Nishi-ku, Kobe 651-2239, JapanPhone: 81-78-991-1133 Fax: 81-78-991-3186

Tokyo OfficeWorld Trade Center Bldg., 4-1, Hamamatsu-cho 2-chome, Minato-ku, Tokyo 105-6116, Japan Phone: 81-3-3435-6862 Fax: 81-3-3435-2023

Kobe OfficeKobe Crystal Tower, 1-3, Higashikawasaki-cho 1-chome, Chuo-ku, Kobe, 650-8680, Japan Phone: 81-78-360-8608 Fax: 81-78-360-8609http://www.khi.co.jp/kpm/

OVERSEAS OFFICES

Seoul Officec/o Kawasaki Machine Systems Korea, Ltd. 3rd Floor (307), Industrial Complex Support Bldg., 637, Kojan-Dong, Namdong-Gu, Incheon, 405-817, KoreaPhone: 82-32-821-6941 Fax: 82-32-821-6947

Beijing OfficeRoom No.2602, China World Tower 1, China World Trade Center, No.1 Jian Guo Men Wai Avenue, Beijing 100004, People's Republic of ChinaPhone: 86-10-6505-1350 Fax: 86-10-6505-1351

Shanghai Office13th Floor, HSBC Tower, 101 Yin Cheng East Road, Pudong New Area, Shanghai 200120, People's Republic of China Phone: 86-21-6841-3377 Fax: 86-21-6841-2266

Taipei Office15th Floor, Fu-Key Bldg., 99 Jen-Ai Road Section 2, Taipei, TaiwanPhone: 886-2-2322-1752 Fax: 886-2-2322-5009

Bangkok Office17th Floor, Ramaland Bldg., 952 Rama IV Road, Bangrak, Bangkok 10500 ThailandPhone: 66-2-632-9511 Fax: 66-2-632-9515

Kuala Lumpur OfficeLetter Box No. 162, 6th Floor, UBN Tower, 10 Jalan P. Ramlee 50250, Kuala Lumpur, MalaysiaPhone: 60-3-2070-5141 Fax: 60-3-2070-5148

Jakarta Office12th Floor, Skyline Bldg., Jl. M. H. Thamrin 9, Jakarta 10340, IndonesiaPhone: 62-21-314-0737 Fax: 62-21-314-1049

OVERSEAS SUBSIDIARIES

Kawasaki Heavy Industries (U.S.A.), Inc. 599 Lexington Avenue, Suite 3901, New York, NY 10022, U.S.A.Phone: 1-212-759-4950 Fax: 1-212-759-6421

Houston Branch333 Clay Street, Suite 4310, Houston, TX 77002-4103, U.S.A.Phone: 1-713-654-8981 Fax: 1-713-654-8187

Kawasaki do Brasil Indústria e Comércio Ltda.Avenida Paulista 542-6 Andar, Bela Vista, 01310-000, São Paulo, S.P., BrazilPhone: 55-11-3289-2388 Fax: 55-11-3289-2788

Kawasaki Heavy Industries (U.K.) Ltd.4th Floor, 3 St. Helen's Place, London EC3A 6AB, U.K.Phone: 44-20-7588-5222 Fax: 44-20-7588-5333

Kawasaki Heavy Industries (Europe) B.V.7th Floor, Riverstaete, Amsteldijk 166, 1079 LH Amsterdam, The NetherlandsPhone: 31-20-6446869 Fax: 31-20-6425725

Kawasaki Heavy Industries (H.K.) Ltd.Room 4211-16, Sun Hong Kai Centre 30 Harbour Road, WanchaiHong Kong People's Republic of ChinaPhone: 852-2522-3560 Fax: 852-2845-2905

Kawasaki Heavy Industries (Singapore) Pte. Ltd.6 Battery Road, #18-04, Singapore 049909Phone: 65-6225-5133~4 Fax: 65-6224-9029

Kawasaki Precision Machinery (UK) LTD. Ernesettle Lane, Ernesettle, Plymouth, Devon PL5 2SA, United KingdomPhone: 44-1752-364394 Fax: 44-1752-364816http://www.kpm-eu.com

Kawasaki Precision Machinery of America Division of Kawasaki Motors Corp., U.S.A.5080, 36th St. S.E. Grand Rapids, MI 49512, U.S.A.Phone: 1-616-949-6500 Fax: 1-616-975-3103http://www.kawasakipmd.com