sustainable strategies

105
Reduce Reuse Reclaim and Recycle Appropriate use of land Use water and energy efficiently Enhance human health Strengthen local economies Conserve plants and animals Sustainable Strategies

Upload: dasan

Post on 25-Feb-2016

35 views

Category:

Documents


0 download

DESCRIPTION

Sustainable Strategies. Reduce Reuse Reclaim and Recycle Appropriate use of land Use water and energy efficiently Enhance human health Strengthen local economies Conserve plants and animals. Sustainable Strategies. Protect agricultural, cultural and archeological resources - PowerPoint PPT Presentation

TRANSCRIPT

Page 1: Sustainable Strategies

Reduce Reuse Reclaim and Recycle

Appropriate use of land

Use water and energy efficiently

Enhance human health

Strengthen local economies

Conserve plants and animals

Sustainable Strategies

Page 2: Sustainable Strategies

Protect agricultural, cultural and archeological resources

Build and maintain economically

Nice to live in

Build it Beautiful

Sustainable Strategies

Page 3: Sustainable Strategies

Healthy Indoor Air

Page 4: Sustainable Strategies

Radon * Radon is estimated to cause

about 21,000 lung cancer deaths per year, according to EPA's 2003 Assessment of Risks from Radon in Homes (EPA 402-R-03-003).  The numbers of deaths from other causes are taken from the Centers for Disease Control and Prevention's 1999-2001 National Center for Injury Prevention and Control Report and 2002 National Safety Council Reports.

Page 5: Sustainable Strategies

Radon

       

Zone 1 counties have a predicted average indoor radon screening level greater than 4 pCi/L (pico curies per liter) (red zones)

Highest Potential

       

Zone 2 counties have a predicted average indoor radon screening level between 2 and 4 pCi/L (orange zones)

Moderate Potential

       

Zone 3 counties have a predicted average indoor radon screening level less than 2 pCi/L (yellow zones)

Low Potential

Page 6: Sustainable Strategies

Radon

Page 7: Sustainable Strategies

What is Radon? A radioactive gas that

comes from the natural decay of uranium and is found in nearly all soils.

Page 8: Sustainable Strategies

Radon Radon gets into the home through

Cracks in concrete floors Construction joints Cracks in walls Gaps in suspended floors Gaps around service pipes Cavities inside walls The water supply (wells typically)

Page 9: Sustainable Strategies

RadonRadon Resistant Construction Techniques Gas Permeable Layer

This layer is placed beneath the slab or flooring system to allow the soil gas to move freely underneath the house. In many cases, the material used is a 4-inch layer of clean gravel. 

Plastic SheetingPlastic sheeting is placed on top of the gas permeable layer and under the slab to help prevent the soil gas from entering the home. In crawlspaces, the sheeting is placed under the crawlspace floor. 

Sealing and CaulkingAll openings in the concrete foundation floor are sealed to reduce soil gas entry into the home. 

Vent PipeA 3- or 4-inch gas-tight or PVC pipe (commonly used for plumbing) runs from the gas permeable layer through the house to the roof to safely vent radon and other soil gases above the house. 

Junction BoxAn electrical junction box is installed in case an electric venting fan is needed later.

Page 10: Sustainable Strategies
Page 11: Sustainable Strategies
Page 12: Sustainable Strategies

Volatile Organic Compounds Volatile organic compounds (VOCs) are

emitted as gases from certain solids or liquids. VOCs include a variety of chemicals, some of which may have short- and long-term adverse health effects.

Page 13: Sustainable Strategies

VOC’s Paints Lacquers Paint Strippers Cleaning Supplies Pesticides Building Materials Furnishings Glues Adhesives………

Page 14: Sustainable Strategies

Health Effects Eye nose and throat irritation Headaches Loss of coordination Nausea Liver damage Kidney damage Central Nervous system damage Cancer

Page 15: Sustainable Strategies

Formaldehyde What is Formaldehyde? Formaldehyde is a low cost and common

chemical that has a strong pickle-like odor. It is currently used in thousands of products as an adhesive, bonding agent and solvent.

Page 16: Sustainable Strategies

Formaldehyde Where is it found?

Particle board, plywood, paneling, pressed-wood products

Urea formaldehyde foam insulation Synthetic fabrics (especially permanent press) Produced through combustion

Natural gas Wood Gasoline Tobacco

Page 17: Sustainable Strategies

FormaldehydeHealth Effects Vary Eye, nose and throat irritation Coughing, headaches, dizziness, and nausea

The effects of long-term exposure are not well known

The United States Environmental Protection Agency has listed formaldehyde as a chemical that can possibly cause cancer in people.

Page 18: Sustainable Strategies

FormaldehydeWhat is an acceptable level in the home?0.10 PPM or less

If a higher level is measured steps should be taken to mitigate the problem

Page 19: Sustainable Strategies

FormaldehydeMethods for lowering levels Remove the source Treat the source Ventilate Control the climate Allow products to off-gas

Page 20: Sustainable Strategies

How are Radon and Formaldehyde Detected?

Radon Detection Kits www.radonzone.com

Formaldehyde www.rkiinstruments.com/pages/fp30.htm

Page 21: Sustainable Strategies

Bathroom Exhaust FansCODE for Baths with bathing or spas facilities:

Minimum 80 CFM Intermittent Ventilation required or

Continuous Ventilation System at 20 cfm

CODE for Toilet Rooms without bathing or spas facilities:

3SF Minimum Window ½ of which must be operable

Minimum 50 CFM Intermittent Ventilation

Page 22: Sustainable Strategies

Home Ventilation Institute Recommendations - Baths Bathrooms to 80SF - 80CFM fan (Code)

Bathrooms 81sf to 100 sf – 1 cfm per square foot (~ 8 air changes/hour)

Bathrooms over 100 sf add the CFM for each fixture Allow 50 CFM per standard toilets, shower and steam

shower (put on timer) Allow 100 CFM per Whirlpool, garden and hot tubs

HVI recommends continuous ventilations as augmentation to intermittent ventilation

Page 23: Sustainable Strategies

Bathroom Exhaust Fans A toilet in its own enclosure should have its own fan

Fans approved for wet areas should be placed over or very near the shower or tub when possible.

Bath doors should be undercut at least 3/4”

Leave fan on for 20 minutes after use of the bathroom

Page 24: Sustainable Strategies

Ventilation ConsiderationsFan Type Propeller Fan – Limited air capacity and noisy

Axial Fan – Better air movement but still noisy

Centrifugal Blower (Squirrel Cage) The best

Page 25: Sustainable Strategies

HumidistatnsHumidistat

Page 26: Sustainable Strategies

Kitchens

Page 27: Sustainable Strategies

Kitchen Exhaust FansCODE (ASHRAE) The American Society of

Heating, Refrigerating and Air-Conditioning Engineers

100 CFM IntermittentOr25 CFM Continuous

Page 28: Sustainable Strategies

Home Ventilation Institute Recommendations - Kitchens Wall Mount Hoods – 100 cfm per foot of width

Island Mount Hoods – 150 cfm per foot of width

Page 29: Sustainable Strategies

Air Flow Rules of ThumbRule of Thumb 1:Take the hood area (in square feet) andmultiply it by 75 to get the CFM (cubic feetper minute) for a wall hood, or multiply it by100 for an island hood.

Rule of Thumb 2:Allow 15 air changes per hour (ACH) for the kitchen.

Take the kitchen volume (length x width x height) and divide by 4 to get the required CFM.

Page 30: Sustainable Strategies

Rule of Thumb 3:

Allow 1 CFM per 100 BTU's per hour (BTUH) heat output.

Take the output of the oven and cooktop (if together or close) and divide by 100 to get the required CFM.

Rule of Thumb 4: (this applies to commercial type ranges)

Allow 100 CFM per linear foot of hood. Take the perimeter of the hood and multiply it by 100 to get

the required CFM.

Which rule of thumb is the best one to use?

The most popular rules of thumb are #1 and #3. We typically use rule of thumb #1 when we size fans.

Page 31: Sustainable Strategies

NKBA Recommendations

Page 32: Sustainable Strategies

Ventilation Calculator

Page 33: Sustainable Strategies

Why Ventilate?To provide enough air to keep occupants health

To remove odors

To dilute indoor pollutants

To lower relative humidity

Page 34: Sustainable Strategies

Negative Aspects Typical home

Gas furnace – vents to outside Gas Hot Water Heater – vents to outside 2 bath fans – vent to outside 1 kitchen ventilator – vents to outside

What happens when the home is winterized, windows closed, doors closed and all of these ventilators are running?

Page 35: Sustainable Strategies

Furnace

Page 36: Sustainable Strategies

Gas dryer

Page 37: Sustainable Strategies

Gas Hot Water Heater

Page 38: Sustainable Strategies

Hot Water Heater Vent

Page 39: Sustainable Strategies

-Negative Pressure Where does the makeup air come from?

Page 40: Sustainable Strategies

Hot Water Heater Vent

Page 41: Sustainable Strategies

Negative Pressure What happens when we tighten the

house up?

Page 42: Sustainable Strategies

How Tight is Too Tight? We need .35 air changes per hour. If less then

mechanical ventilation must be used

1500 SF house with 8’-0” ceilings

What is the total air volume inside the house? 12000 CF How many CFM do we need to move? 4200/60 = 70 CFM

Page 43: Sustainable Strategies

Heat Recovery Ventilator

Page 44: Sustainable Strategies

HRV

Page 45: Sustainable Strategies

HRV

Page 46: Sustainable Strategies

ERV Energy Recovery Ventilator Energy Recovery Ventilator Used in the southern states where

humidity is a problem Works the same as a HRV but ~ 9% of

the stale air mixes with the fresh air to adjust humidity.

Page 47: Sustainable Strategies

Bioclimate Chart

Page 48: Sustainable Strategies

Example 1 Dry Bulb 73° Relative Humidity 50%

Page 49: Sustainable Strategies

In the zone

Page 50: Sustainable Strategies

Example 2 Dry Bulb Temp. 78° Relative Humidity 70%

Page 51: Sustainable Strategies
Page 52: Sustainable Strategies

Example 2Dry Bulb Temp.

78°Relative Humidity

70%

Requires a wind speed of 250 FPM(250*60)/5280MPH = 2.84

Page 53: Sustainable Strategies

Example 3 Dry Bulb Temp. = 50°F Relative Humidity 55%

Page 54: Sustainable Strategies
Page 55: Sustainable Strategies

Example 4 Dry Bulb Temp. = 64°F Relative Humidity 40%

Page 56: Sustainable Strategies
Page 57: Sustainable Strategies

What Does All This Mean?

Page 58: Sustainable Strategies

Seasonal Enemies

RADIATION

CONDUCTION

CONVECTION

RADIATION

CONVECTIONCONDUCTION

Cooling: Heating:

Page 59: Sustainable Strategies

British Thermal Units The basic measure of heat The amount of heat needed to raise one

pound of water one degree Fahrenheit

BTU =

A kitchen match contains about 1 BTU of Heat Energy

Page 60: Sustainable Strategies

Heat Content of Fuels 1 Kilowatt-hour electricity = 3,413 Btu 1 cubic foot of natural gas = 1,025 Btu 1 gallon fuel oil = 138,700 Btu 1 gallon kerosene = 135,000 Btu 1 ton of coal = 27,000,000 BTU 1 gallon LPG = 91,000 Btu 1 pound LPG = 21,500 Btu

Page 61: Sustainable Strategies

Energy and Power Power is the INSTANTANEOUS use of energy

Think of it as POTENTIAL use, whether it is running or not (engine, light bulb)

Btu/h Watts, Kilowatts (Watts = Volts x Amps)

the amount of voltage across a circuit x the current through the circuit

Energy is USE of power over TIME (heat energy) Btu/h x hours = Btu Watts x hours = Watt hour (Kilowatt x h = kWh)

Page 62: Sustainable Strategies

FUELSNatural Gas - Piped in under

pressure Liquid Propane (LP) Stored in home

tankFuel OilElectricityCoalWood

Page 63: Sustainable Strategies

Forced Air Furnaces Gas AFUE - annual fuel-utilization-efficiency rating measured as a percentage

The higher the percentage, the more heat the furnace can ring from each therm of gas—and the lower the environmental impact of its emissions.

The lowest allowed is 78%

The most efficient models have an AFUE of about 97 percent—or near-total efficiency.

Page 64: Sustainable Strategies

Energy Star Qualified Minimum AFUE of 85% to 90%

Page 65: Sustainable Strategies

HEPA Filter

Page 66: Sustainable Strategies
Page 67: Sustainable Strategies

Standard Efficiency Furnace Steady State Efficiency or Combustion

Efficiency ~80% Annual Fuel Utilization Efficiently

(~65%)

Page 68: Sustainable Strategies

Standard Efficiency Furnace Incomplete Combustion 0.5 On-Cycle Stack Loss 20% to 25% Pilot Light Loss 6% Off Cycle Loss 0-10% Jacket Loss 0-0.2% Cycling Losses 0-10% Duct Losses 0-40%

Actual Heating System Delivered? 40%-65%

Page 69: Sustainable Strategies

High Efficiency Furnace Steady State Efficiency or Combustion

Efficiency ~90%

Annual Fuel Efficiency (AFUE Rate) ~90%

Page 70: Sustainable Strategies

High Efficiency Furnace Incomplete Combustion 0.5 On-Cycle Stack Loss <10% Pilot Light Loss 0% Off Cycle Loss 0% Jacket Loss 0-0.2% Cycling Losses 0-10% Duct Losses 0-40%

Actual Heating System Delivered? 70%-90%

Page 71: Sustainable Strategies

Two Measures of Efficiency in Heat Pumps HSPF – Heating SEER - Cooling

Page 72: Sustainable Strategies

Heating Seasonal Performance Factor (HSPF) BTU’s produced/watt-hours

Heat Pumps manufactured after 2005 must have a HSPF of at least 7.7

The Most efficient have a HSFP of 10

Page 73: Sustainable Strategies

Seasonal Energy Efficiency Ratio(SEER)

Power output/Power input The higher the number the more efficient

All Air Conditioning units sold after January 2006 must have a SEER rating of at least 13.

Energy Star central air conditioning must have a SEER rating of 14

Window air conditioners are exempt from this rating

Updating from a 9 SEER rated system to a 13 can save 30% on your energy consumption

Page 74: Sustainable Strategies

Pros and Cons of Heat Pumps Electrically Powered

Can be used in conjunction with a forced air furnace

Not well suited in extremely cold climate

Noise

Page 75: Sustainable Strategies

Radiant Floor HeatThree types Radiant Air Floors

Electric Radiant Floors

Hot Water (Hydronic)

Page 76: Sustainable Strategies

Radiant Floor HeatTypes of installationWet Installations Large thermal mass of a concrete slab floor lightweight concrete over a wooden subfloor Dry Installations Where the installer "sandwiches" the radiant floor

tubing between two layers of plywood or attaches the tubing under the finished floor or subfloor.

Page 77: Sustainable Strategies

Radiant Floor Heat Air Heated Radiant Floors Not

recommended for residential applications

Electric Radiant Floors -

Page 78: Sustainable Strategies

Electric Radiant Heat - Wet Installation

Page 79: Sustainable Strategies

Wet Installation

Page 80: Sustainable Strategies

Wet Installation

Page 81: Sustainable Strategies

Dry Installation

Page 82: Sustainable Strategies

Dry Installation

Page 83: Sustainable Strategies

Hydronic Radiant Heat

Page 84: Sustainable Strategies

Wet Installation PEX piping in Concrete (thick slab)

Page 85: Sustainable Strategies
Page 86: Sustainable Strategies
Page 87: Sustainable Strategies

Wet Installation Thin Slab Application Gypcrete over

plywd

Page 88: Sustainable Strategies

Heat Pump and Air Handler

Heat Pump

Air Handler

Air Cleaner

Thermostat

Page 89: Sustainable Strategies

Heat Pump and FurnaceIndoor Cooling Coil

Heat PumpFurnace

Air Cleaner

Thermostat

Page 90: Sustainable Strategies

Cooling

Page 91: Sustainable Strategies

Cooling

Page 92: Sustainable Strategies

Air Conditioner and Furnace

Air Conditioner

Furnace

Indoor Cooling Coil

Thermostat

Air Cleaner

Page 93: Sustainable Strategies

Air Conditioners and Air Handlers

Thermostat

Air Conditioner

Air Handler

Air Cleaner

Page 94: Sustainable Strategies

Cooling

Page 95: Sustainable Strategies

Whole House Ventilation

Page 96: Sustainable Strategies

Natural Ventilation

Page 97: Sustainable Strategies

Natural Ventilation

Page 98: Sustainable Strategies

Ceiling FansSizing Ceiling FansLargest dimension of room

Minimum Fan Diameter

12 feet or less 36-inches12 -16 feet 48-inches16 – 17.5 feet 52-inches17.5 -18.5 feet 56-inches18.5 feet 2 fans

Page 99: Sustainable Strategies
Page 100: Sustainable Strategies

http://www.matthewsfanco.com

Page 101: Sustainable Strategies

Heating Degree Days Heating Degree Days are a measure of

how cold your climate is. If the average outside temperature for a

day is 1 degree less than the inside temperature (68°), then you would accumulate 1 degree day on that day.

http://www.ncdc.noaa.gov/oa/climate/online/ccd/nrmhdd.txt

Page 102: Sustainable Strategies

Portland Month starting HDD % Estimated 11/1/2011 603 0 12/1/2011 805 0 1/1/2012 749 0 2/1/2012 633 0.03 3/1/2012 622 0 4/1/2012 384 0 5/1/2012 282 0 6/1/2012 176 0 7/1/2012 69 0 8/1/2012 50 0 9/1/2012 110 0 10/1/2012 305 0.03 4788

Page 103: Sustainable Strategies

UA Calculation R = (A * Δ T) / (3.413 * W)

W = Watts 3.413 = Constant (BTU/Watt) ΔT = Change in temp A = Area in Square Feet

Page 104: Sustainable Strategies

R = (A * Δ T) / (3.413 * W)

Outside Temperature = 35° Heat source = 100 Watts Total Area = 520 SF Temperature inside = 55°

Calculate the R Value for the given area

R30

Page 105: Sustainable Strategies

R = (A * Δ T) / (3.413 * W)

Outside Temperature = 20° Insulation = R30 Total Area = 3520 SF Home 30x40x8 Temperature inside = 68°

Calculate wattage of the heat source for the given area

1650.16Watts