surface water about us elemental analysis material
TRANSCRIPT
UNIVERSITI PUTRA
MALAYSIA (UPM)
ABOUT US
Experienced, trained and very competent analyst.
MATERIAL CHARACTERIZATION
LABORATORY
Support all research activities for undergraduate and post graduate studies.
Accredited with MS ISO/IEC 17025:2015 (SAMM No. 711) for two analytical services under the cluster of chemical and physical.
We offer facilities for chemical and physical c h a r a c t e r i z a t i o n testing and services including imaging, s p e c t r o s c o p y , c h r o m a t o g r a p h y , thermal and laser analysis.
SURFACE WATER ELEMENTAL
ANALYSIS
Accepted Sample Criteria:
Treated Clear Surface
Water Sample
Minimum volume 20mL
Standard is provided
Testing are based on
APHA 3111B
Accepted Sample
Criteria:
Amorphous region:
from 30 to 300°C
Sample weight:
5 to 20mg
Example of sample:
polymeric material and mixture plastic, fibers
and adhesive
Testing are based on
ASTM E 1356-98 &
ASTM E 967-03
We offer to you the Glass Transition (Tg)
determination testing for amorphous materials, partially crystalline materials using Differential Scanning Calorimetry (DSC)
Type Of Surface Water :
Reservoir
Wetland
River
Lake
The determination of elemental concentration by using Flame Atomic Absorption Spectrometry (AAS) at parts per million (ppm) level.
PRICE:
RM230/SAMPLE
FOR MORE INFORMATION, PLEASE CONTACT :
MATERIAL CHARACTERIZATION LABORATORY DEPARTMENT OF CHEMICAL AND ENVIRONMENTAL ENGINEERING, FACULTY OF ENGINEERING, UNIVERSITI PUTRA MALAYSIA, 43400 UPM SERDANG, SELANGOR, MALAYSIA.
TEL : +603-89471595
FAX: +603-86567120
EMAIL: [email protected]
MATERIAL
CHARACTERIZATION
LABORATORY
(MCL)
PRICE:
RM80/ELEMENT/
SAMPLE
GLASS TRANSITION (Tg) DETERMINATION
ANALYSIS
Elements Concentration range (ppm)
Nickel (Ni) 0.09 to 0.30
Zinc (Zn) 0.10 to 1.00
Copper (Cu) 0.10 to 1.00
SPECTROSCOPY ANALYSIS
ANALYSIS UNIT/
INSTRUMENT PRICE (RM)
Elemental analysis especially in surface water sample
Atomic Absorption
Spectrophotometer (AAS)
80/element/sample
An analytical technique (Detection of trace metals in environmental samples)
Inductively Coupled Plasma
(ICP-OES)
190 (fixed cost) and 7/
element/sample
Functional group determination
ATR technique
Fourier Transform Infra-red
Spectroscopy (FTIR )
130/sample
Analysis of compound
In a range of observed light & UV light
UV-Visible Spectrophotometer
(UV-Vis) 50/hour
ANALYSIS UNIT/
INSTRUMENT PRICE (RM)
Glass transition (Tg)
Melting point
Crystallinity
Specific heat
Differential Scanning
Calorimetry (DSC) 230/sample
Compositional Analysis
Thermal Gravimetric
Analysis (TGA) 230/sample
Elemental analysis C, H, N, S
Liquid or solid sample
CHNS Analyzer
CHN: 260/sample
S: 250/sample
Mechanical and strength testing
Room temperature
to 600°C only
Dynamic
Mechanical
Analyzer (DMA)
170/sample
CHROMATOGRAPHY ANALYSIS
ANALYSIS UNIT/
INSTRUMENT PRICE (RM)
Compound separation in gas or liquid form.
Gas Chromatography (GC)- FID/ECD
130 (1st injection) and 30/injection for subsequent
injection
Gas Chromatography
(GC)- TCD
80 (1st injection) and 40/injection for subsequent
injection
Gas Chromatography
Mass Spectrometry
(GC-MS)
380/sample
High Performance Liquid
Chromatography (HPLC) UV
105 (fixed cost) & 45 for subsequent
Injection Separate and Identify liquid compound
High resolution chromatography technique
High Performance Liquid
Chromatography (HPLC) RI/ELSD
Detector
100 (fixed cost) & 35 for subsequent
Injection
ANALYSIS PRICE (RM)
Biological Oxygen Demand (BOD) 50/sample
Chemical Oxygen Demand (COD) 100/sample
Total Organic Content (TOC) 10/sample
Turbidity 30/sample
pH 5/ sample
Total Dissolved Solid (TDS) 10/sample
Total Suspended Solid (TSS) 30/sample
Bomb Calorimeter 30/sample
ANALYSIS UNIT/
INSTRUMENT PRICE (RM)
A Microscope uses electron to form an image
Scanning Electron
Microscope (SEM) 240/sample
Elemental analysis or chemical characterization of a sample
Scanning Electron
Microscope With Energy-dispersive X
-ray spectroscopy (SEM-EDX)
385/sample
WATER ANALYSIS
MICROSCOPY ANALYSIS
THERMAL ANALYSIS
ANALYSIS UNIT/
INSTRUMENT PRICE (RM)
Surface area and porosity characterization
Brunauer- Emmett-Teller (BET)
Analyzer 425/sample
ANALYSIS UNIT/
INSTRUMENT PRICE (RM)
Measure the size of sample distribution using laser diffraction
Micrometer range (0.1-1000)
Particle Size Analyzer (Malvern)
55/sample
LASER ANALYSIS
PHYSICAL ANALYSIS