UNIVERSITI PUTRA

MALAYSIA (UPM)

ABOUT US

Experienced, trained and very competent analyst.

MATERIAL CHARACTERIZATION

LABORATORY

Support all research activities for undergraduate and post graduate studies.

Accredited with MS ISO/IEC 17025:2015 (SAMM No. 711) for two analytical services under the cluster of chemical and physical.

We offer facilities for chemical and physical c h a r a c t e r i z a t i o n testing and services including imaging, s p e c t r o s c o p y , c h r o m a t o g r a p h y , thermal and laser analysis.

SURFACE WATER ELEMENTAL

ANALYSIS

Accepted Sample Criteria:

Treated Clear Surface

Water Sample

Minimum volume 20mL

Standard is provided

Testing are based on

APHA 3111B

Accepted Sample

Criteria:

Amorphous region:

from 30 to 300°C

Sample weight:

5 to 20mg

Example of sample:

polymeric material and mixture plastic, fibers

and adhesive

Testing are based on

ASTM E 1356-98 &

ASTM E 967-03

We offer to you the Glass Transition (Tg)

determination testing for amorphous materials, partially crystalline materials using Differential Scanning Calorimetry (DSC)

Type Of Surface Water :

Reservoir

Wetland

River

Lake

The determination of elemental concentration by using Flame Atomic Absorption Spectrometry (AAS) at parts per million (ppm) level.

PRICE:

RM230/SAMPLE

FOR MORE INFORMATION, PLEASE CONTACT :

MATERIAL CHARACTERIZATION LABORATORY DEPARTMENT OF CHEMICAL AND ENVIRONMENTAL ENGINEERING, FACULTY OF ENGINEERING, UNIVERSITI PUTRA MALAYSIA, 43400 UPM SERDANG, SELANGOR, MALAYSIA.

TEL : +603-89471595

FAX: +603-86567120

EMAIL: [email protected]

MATERIAL

CHARACTERIZATION

LABORATORY

(MCL)

PRICE:

RM80/ELEMENT/

SAMPLE

GLASS TRANSITION (Tg) DETERMINATION

ANALYSIS

Elements Concentration range (ppm)

Nickel (Ni) 0.09 to 0.30

Zinc (Zn) 0.10 to 1.00

Copper (Cu) 0.10 to 1.00

SPECTROSCOPY ANALYSIS

ANALYSIS UNIT/

INSTRUMENT PRICE (RM)

Elemental analysis especially in surface water sample

Atomic Absorption

Spectrophotometer (AAS)

80/element/sample

An analytical technique (Detection of trace metals in environmental samples)

Inductively Coupled Plasma

(ICP-OES)

190 (fixed cost) and 7/

element/sample

Functional group determination

ATR technique

Fourier Transform Infra-red

Spectroscopy (FTIR )

130/sample

Analysis of compound

In a range of observed light & UV light

UV-Visible Spectrophotometer

(UV-Vis) 50/hour

ANALYSIS UNIT/

INSTRUMENT PRICE (RM)

Glass transition (Tg)

Melting point

Crystallinity

Specific heat

Differential Scanning

Calorimetry (DSC) 230/sample

Compositional Analysis

Thermal Gravimetric

Analysis (TGA) 230/sample

Elemental analysis C, H, N, S

Liquid or solid sample

CHNS Analyzer

CHN: 260/sample

S: 250/sample

Mechanical and strength testing

Room temperature

to 600°C only

Dynamic

Mechanical

Analyzer (DMA)

170/sample

CHROMATOGRAPHY ANALYSIS

ANALYSIS UNIT/

INSTRUMENT PRICE (RM)

Compound separation in gas or liquid form.

Gas Chromatography (GC)- FID/ECD

130 (1st injection) and 30/injection for subsequent

injection

Gas Chromatography

(GC)- TCD

80 (1st injection) and 40/injection for subsequent

injection

Gas Chromatography

Mass Spectrometry

(GC-MS)

380/sample

High Performance Liquid

Chromatography (HPLC) UV

105 (fixed cost) & 45 for subsequent

Injection Separate and Identify liquid compound

High resolution chromatography technique

High Performance Liquid

Chromatography (HPLC) RI/ELSD

Detector

100 (fixed cost) & 35 for subsequent

Injection

ANALYSIS PRICE (RM)

Biological Oxygen Demand (BOD) 50/sample

Chemical Oxygen Demand (COD) 100/sample

Total Organic Content (TOC) 10/sample

Turbidity 30/sample

pH 5/ sample

Total Dissolved Solid (TDS) 10/sample

Total Suspended Solid (TSS) 30/sample

Bomb Calorimeter 30/sample

ANALYSIS UNIT/

INSTRUMENT PRICE (RM)

A Microscope uses electron to form an image

Scanning Electron

Microscope (SEM) 240/sample

Elemental analysis or chemical characterization of a sample

Scanning Electron

Microscope With Energy-dispersive X

-ray spectroscopy (SEM-EDX)

385/sample

WATER ANALYSIS

MICROSCOPY ANALYSIS

THERMAL ANALYSIS

ANALYSIS UNIT/

INSTRUMENT PRICE (RM)

Surface area and porosity characterization

Brunauer- Emmett-Teller (BET)

Analyzer 425/sample

ANALYSIS UNIT/

INSTRUMENT PRICE (RM)

Measure the size of sample distribution using laser diffraction

Micrometer range (0.1-1000)

Particle Size Analyzer (Malvern)

55/sample

LASER ANALYSIS

PHYSICAL ANALYSIS