subravsp240krtat2-1 rav-sp240krt-ul rav-sp240at2 … · title: microsoft word - subravsp240krtat2-1...

3
Copyright 2014 Carrier Corp. S 7310 W. Morris St. S Indianapolis, IN 46231 Edition Date: 08/14 Catalog No: SUBRAVSP240KRTAT2-1 Manufacturer reserves the right to change, at any time, specifications and designs without notice and without obligations. Replaces: NEW 1 High Wall Residential Heat Pump System Indoor Model: RAV-SP240KRT-UL Outdoor Model: RAV-SP240AT2-UL Submittal Data Job Data: _________________________________________________ Location: ______________________________________ _________ Buyer: ________________________________________ Buyer P.O. #_______________________ Carrier # _________________________ Unit Number: __________________________________ Model Number: _____________________________________________________ Performance Data Certified By: _________________________________________ Date: __________________________________________ HIGH WALL STANDARD FEATURES Digital inverter compressor technology Turbo mode setting for quick temperature adjustment System can operate in cooling only mode with heating locked out Line lengths up to 165' Wireless controller included Auto louver mode Quiet operation 3 indoor unit fan speeds Low-ambient cooling down to 5°F Filter maintenance indicator Clean mode Indoor sound: as low as 38 decibels System diagnostics CONTROL STANDARD FEATURES Wireless remote control standard Code display on controller Turbo mode Multiple wireless control operation (Unless otherwise indicated, data applies to both indoor and outdoor models) SYSTEM SIZE ........................................................................................ 24 REFRIGERANT ...................................................................... R-410A PERFORMANCE Rated Cooling Capacity (Btuh) ................................................... 25,000 Cooling Range (Btuh)...................................................... 4,100–32,600 SEER/EER ............................................................................... 16.7/9.1 Rated Heating Capacity (Btuh) .................................................. 26,400 Heating Range (Btuh) ...................................................... 3,480-30,400 HSPF ................................................................................................ 9.8 CFM/Sound Pressure dBA Outdoor Sound Pressure (dBA) ................................................. 49/50 Indoor Cooling Airflow H / M / L (cfm) ............................. 530/420/370 Indoor Cooling at Different Speeds (dBA) ............................. 46/41/38 Indoor Heating Airflow H / M / L (cfm) ............................. 530/420/370 Indoor Heating at Different Speeds (dBA) ............................ 46/41/38 ELECTRICAL System Voltage.................................................................... 208/230 -1-60 Indoor Unit .................................................................. Wired from Outdoor Wires between Indoor and Outdoor ......................................................... 4 MCA ........................................................................................................ 24 MOCP ..................................................................................................... 40 CONTROLS Wireless Remote ......................................................................... Standard Wired Control .................................................................................Optional REFRIGERANT LINES Total Piping Length (ft) ......................................................................... 165 Vertical Lift (ft) ........................................................................... ………98.5 Suction Line Size (in)............................................................................. 1/2 Liquid Line Size (in) ............................................................................... 1/4 AMBIENT OPERATING RANGE Cooling DB Min ~ Max (F) .............................. 23~110 (5 with wind baffle) Heating DB Min ~ Max (F)................................................................. -4~59 UNIT WEIGHT - Gross/Net Indoor unit (lbs) .................................................................................. 36/31 Outdoor unit (lbs) ........................................................................ 157/144.5 Accessories: Condensate Pump 208/230V Wired Control RAV – Convertible

Upload: tranbao

Post on 15-Feb-2019

220 views

Category:

Documents


0 download

TRANSCRIPT

Page 1: SUBRAVSP240KRTAT2-1 RAV-SP240KRT-UL RAV-SP240AT2 … · Title: Microsoft Word - SUBRAVSP240KRTAT2-1 RAV-SP240KRT-UL_RAV-SP240AT2-UL (HIGH WALL).docx Author: bact04l Created Date:

Copyright 2014 Carrier Corp. S 7310 W. Morris St. S Indianapolis, IN 46231 Edition Date: 08/14 Catalog No: SUBRAVSP240KRTAT2-1

Manufacturer reserves the right to change, at any time, specifications and designs without notice and without obligations. Replaces: NEW

1

High Wall Residential Heat Pump System Indoor Model: RAV-SP240KRT-UL Outdoor Model: RAV-SP240AT2-UL

Submittal Data

Job Data: _________________________________________________ Location: ______________________________________ _________

Buyer: ________________________________________ Buyer P.O. #_______________________ Carrier # _________________________

Unit Number: __________________________________ Model Number: _____________________________________________________

Performance Data Certified By: _________________________________________ Date: __________________________________________

HIGH WALL STANDARD FEATURES

Digital inverter compressor technology Turbo mode setting for quick temperature adjustment System can operate in cooling only mode with heating locked out Line lengths up to 165' Wireless controller included Auto louver mode Quiet operation 3 indoor unit fan speeds Low-ambient cooling down to 5°F Filter maintenance indicator Clean mode Indoor sound: as low as 38 decibels System diagnostics

CONTROL STANDARD FEATURES

Wireless remote control standard Code display on controller Turbo mode Multiple wireless control operation

(Unless otherwise indicated, data applies to both indoor and outdoor models)

SYSTEM SIZE ........................................................................................ 24 REFRIGERANT ...................................................................... R-410A PERFORMANCE Rated Cooling Capacity (Btuh) ................................................... 25,000 Cooling Range (Btuh) ...................................................... 4,100–32,600 SEER/EER ............................................................................... 16.7/9.1 Rated Heating Capacity (Btuh) .................................................. 26,400 Heating Range (Btuh) ...................................................... 3,480-30,400 HSPF ................................................................................................ 9.8 CFM/Sound Pressure dBA Outdoor Sound Pressure (dBA) ................................................. 49/50 Indoor Cooling Airflow H / M / L (cfm) ............................. 530/420/370 Indoor Cooling at Different Speeds (dBA) ............................. 46/41/38 Indoor Heating Airflow H / M / L (cfm) ............................. 530/420/370 Indoor Heating at Different Speeds (dBA) ............................ 46/41/38 ELECTRICAL System Voltage.................................................................... 208/230 -1-60 Indoor Unit .................................................................. Wired from Outdoor

Wires between Indoor and Outdoor ......................................................... 4 MCA ........................................................................................................ 24 MOCP ..................................................................................................... 40 CONTROLS Wireless Remote ......................................................................... Standard Wired Control ................................................................................. Optional REFRIGERANT LINES Total Piping Length (ft) ......................................................................... 165 Vertical Lift (ft) ........................................................................... ………98.5 Suction Line Size (in) ............................................................................. 1/2 Liquid Line Size (in) ............................................................................... 1/4 AMBIENT OPERATING RANGE Cooling DB Min ~ Max (F) .............................. 23~110 (5 with wind baffle) Heating DB Min ~ Max (F)................................................................. -4~59 UNIT WEIGHT - Gross/Net Indoor unit (lbs) .................................................................................. 36/31 Outdoor unit (lbs) ........................................................................ 157/144.5

Accessories: Condensate Pump 208/230V Wired Control RAV – Convertible

Page 2: SUBRAVSP240KRTAT2-1 RAV-SP240KRT-UL RAV-SP240AT2 … · Title: Microsoft Word - SUBRAVSP240KRTAT2-1 RAV-SP240KRT-UL_RAV-SP240AT2-UL (HIGH WALL).docx Author: bact04l Created Date:

Copyright 2014 Carrier Corp. S 7310 W. Morris St. S Indianapolis, IN 46231 Edition Date: 08/14 Catalog No: SUBRAVSP240KRTAT2-1

Manufacturer reserves the right to change, at any time, specifications and designs without notice and without obligations. Replaces: NEW

2

Construction View: Indoor Unit RAV-SP240KRT-UL

Page 3: SUBRAVSP240KRTAT2-1 RAV-SP240KRT-UL RAV-SP240AT2 … · Title: Microsoft Word - SUBRAVSP240KRTAT2-1 RAV-SP240KRT-UL_RAV-SP240AT2-UL (HIGH WALL).docx Author: bact04l Created Date:

Copyright 2014 Carrier Corp. S 7310 W. Morris St. S Indianapolis, IN 46231 Edition Date: 08/14 Catalog No: SUBRAVSP240KRTAT2-1

Manufacturer reserves the right to change, at any time, specifications and designs without notice and without obligations. Replaces: NEW

3

Construction View: Outdoor Unit RAV-SP240AT2-UL