status of the rt ch- cavity

19
Status of the rt CH- cavity - Anja Seibel -

Upload: xantha-hewitt

Post on 01-Jan-2016

24 views

Category:

Documents


2 download

DESCRIPTION

Status of the rt CH- cavity. - Anja Seibel -. Outline. CH- Cavity CH-Parameter Heat distribution Cooling concept Final CH- Cavity First measurement results. CH- Cavity. CH- Cavity. the CH- Cavity consists of 5 gaps with an operating frequency of 175 MHz - PowerPoint PPT Presentation

TRANSCRIPT

Status of the rt CH-cavity

- Anja Seibel -

Anja Seibel 2

Outline

• CH-Cavity• CH-Parameter• Heat distribution• Cooling concept• Final CH-Cavity• First measurement results

02.10.2013

Anja Seibel 3

CH-Cavity

02.10.2013

Anja Seibel 4

• the CH-Cavity consists of 5 gaps with an operating frequency of 175 MHz

• the cavity has a diameter of about 770 mm (665,4 mm Tank inner diameter) and a length of 463 mm (383 mm Tank inner length)

CH-Cavity

02.10.2013

21 mm

30 mm34 mm

24 mm

463 mm

770

mm

Anja Seibel 502.10.2013

• 1 Inductive input coupler• 4 Pick ups• 2 Tuners• 1 Vacuum pump port

1

2 3

4

CH-Cavity

Anja Seibel 6

CH-Cavity

02.10.2013

• The tuning is done by two cylindrical tuners. One is adjustable in height (80 mm) and one is static

Anja Seibel 702.10.2013

CH-Cavity

220 mm

Dyn. Tuner [mm] 160 220 240

Frequency [MHz] 176.0 175.3 174.6

Anja Seibel 8

CH- Parameter

02.10.2013

Parameter Unit Value

Gaps 5

Frequency MHz 175

Tank length mm 383

Tank diameter mm 665.4

Aperture diameter mm 24

Effective Voltage kV 325

Q-Factor 14000

Shunt impedance MΩ/m 80

Losses kW 5

Anja Seibel 9

Heat distribution

02.10.2013

rf current density distribution temperature distribution

Anja Seibel 10

Cooling concept

02.10.2013

Cooling concept for the drift tubes and the stems

Anja Seibel 1102.10.2013

Cooling concept

Anja Seibel 1202.10.2013

Cooling conceptCooling concept for the tank:• 16 cooling channels with a diameter of 10 mm

Anja Seibel 13

Final CH-cavity

02.10.2013

Anja Seibel 14

Final CH-cavity

02.10.2013

Anja Seibel 15

Final CH-cavity

02.10.2013

Anja Seibel 16

Final CH-cavity

02.10.2013

Anja Seibel 17

First measurement results

02.10.2013

Dyn. Tuner [mm] 160 220 240

Frequency [MHz] 175.7 175.1 174.5

Dyn. Tuner [mm] 160 220 240

Frequency [MHz] 176.0 175.3 174.6

Measurement

Simulation

Anja Seibel 18

Electrical field profile

02.10.2013

First measurement resultsSimulation Measurement

Anja Seibel 1902.10.2013

Thanks for your attention!