status of the rt ch- cavity
DESCRIPTION
Status of the rt CH- cavity. - Anja Seibel -. Outline. CH- Cavity CH-Parameter Heat distribution Cooling concept Final CH- Cavity First measurement results. CH- Cavity. CH- Cavity. the CH- Cavity consists of 5 gaps with an operating frequency of 175 MHz - PowerPoint PPT PresentationTRANSCRIPT
Anja Seibel 2
Outline
• CH-Cavity• CH-Parameter• Heat distribution• Cooling concept• Final CH-Cavity• First measurement results
02.10.2013
Anja Seibel 4
• the CH-Cavity consists of 5 gaps with an operating frequency of 175 MHz
• the cavity has a diameter of about 770 mm (665,4 mm Tank inner diameter) and a length of 463 mm (383 mm Tank inner length)
CH-Cavity
02.10.2013
21 mm
30 mm34 mm
24 mm
463 mm
770
mm
Anja Seibel 502.10.2013
• 1 Inductive input coupler• 4 Pick ups• 2 Tuners• 1 Vacuum pump port
1
2 3
4
CH-Cavity
Anja Seibel 6
CH-Cavity
02.10.2013
• The tuning is done by two cylindrical tuners. One is adjustable in height (80 mm) and one is static
Anja Seibel 702.10.2013
CH-Cavity
220 mm
Dyn. Tuner [mm] 160 220 240
Frequency [MHz] 176.0 175.3 174.6
Anja Seibel 8
CH- Parameter
02.10.2013
Parameter Unit Value
Gaps 5
Frequency MHz 175
Tank length mm 383
Tank diameter mm 665.4
Aperture diameter mm 24
Effective Voltage kV 325
Q-Factor 14000
Shunt impedance MΩ/m 80
Losses kW 5
Anja Seibel 1202.10.2013
Cooling conceptCooling concept for the tank:• 16 cooling channels with a diameter of 10 mm
Anja Seibel 17
First measurement results
02.10.2013
Dyn. Tuner [mm] 160 220 240
Frequency [MHz] 175.7 175.1 174.5
Dyn. Tuner [mm] 160 220 240
Frequency [MHz] 176.0 175.3 174.6
Measurement
Simulation