I TYP. r ;TYP.
-31-16,�, �1- 112-,, EACH or� EACHSIDE SIDE
SHOE DEPTH SEE PLAN
½" FACE OF WEB (64 mm)
3/4" 0 BOLTS @ 3" (76 mm) CIC
![Page 2: Standard Connection Details - Canam Bâtiments...CANAM Standard Connection Details REVISED AUGUST 2017](https://reader030.vdocuments.us/reader030/viewer/2022040121/5ec0a3f01aa58a26e72d491b/html5/thumbnails/2.jpg)
FLANGE WIDTH FROM 4"(100 mm) TO 4 ¼" (124 mm) '
FLANGE WIDTH FROM 5"(127 mm) TO 5 ¼"(148 mm) '
FLANGE WIDTH FROM 6"(150 mm) TO 13 1½6" (348 mm'.
FLANGE WIDTH EQUAL OR OVER 13 ¾"(349 mm)
/
/
/
/
/
2¼" (58 mm) /
I 2 ¾" (70 mm) /
4" (102 mm) /
/
I 6" (152 mm)
/
/
I
I I
TYPICAL GAUGES
1. WHEN ONE JOIST BEARS AT THE JUNCTION OFTWO DIFFERENT BEAMS, USE THE SMALLERGAUGE.
2. THERE MAY BE DESIGN CONDITIONS THATDICTATE VARIANCES ON THESECONNECTIONS. FOR COORDINATION,CONTACT YOUR LOCAL SUPPLIER.
3. FOR SKEWED BEAM OR COLUMN, SEE JOISTTYPE 20W AND 20X.
![Page 3: Standard Connection Details - Canam Bâtiments...CANAM Standard Connection Details REVISED AUGUST 2017](https://reader030.vdocuments.us/reader030/viewer/2022040121/5ec0a3f01aa58a26e72d491b/html5/thumbnails/3.jpg)
TCX
r < TYP. TYP. -----.-/._ EACHEACH or ) 5 V 40 SIDE
J--3/-16 -=-=-,,T"?:1�11 1 '2"1'"" , SIDE
JOIST TYPE
![Page 4: Standard Connection Details - Canam Bâtiments...CANAM Standard Connection Details REVISED AUGUST 2017](https://reader030.vdocuments.us/reader030/viewer/2022040121/5ec0a3f01aa58a26e72d491b/html5/thumbnails/4.jpg)
(£_
EE TYPICAL GAUGES
"X" 0 BOLTS@ 5 1/2" (140 mm) CIC
JOIST TYPE BOLTS NOT SUPPLIED BY CANAM (CANAM PREFERRED BOLT DIA.
FOR JOIST SEAT IS 3/4")
1X
![Page 5: Standard Connection Details - Canam Bâtiments...CANAM Standard Connection Details REVISED AUGUST 2017](https://reader030.vdocuments.us/reader030/viewer/2022040121/5ec0a3f01aa58a26e72d491b/html5/thumbnails/5.jpg)
½" (13 mm) CLEAR MIN.
EE TYPICAL GAUGES "X" 0 BOLTS@ 5 1/2" (140 mm) CIC
COLUMN-SEE PLAN PL½" X6" X6"
(NOT SUPPLIED BY CANAM)
DO NOT WELD BOTTOM CHORD
TO STABILIZER PLATE
JOIST TYPE BOLTS NOT SUPPLIED BY CANAM (CANAM PREFERRED BOLT DIA.
FOR JOIST SEAT IS 3/4")
![Page 6: Standard Connection Details - Canam Bâtiments...CANAM Standard Connection Details REVISED AUGUST 2017](https://reader030.vdocuments.us/reader030/viewer/2022040121/5ec0a3f01aa58a26e72d491b/html5/thumbnails/6.jpg)
½" (13 mm) CLEAR MIN.
COLUMN-SEE PLAN
TYP. r <
TYP.--�1-1-12-,, EACH or)
5 V40 EACH
SIDE SIDE
SHOE DEPTH SEE PLAN
2½" (64 mm)
3/4" 0 BOLTS @ 3" (76 mm) CIC
JOIST TYPE 2X BOLTS NOT SUPPLIED BY CANAM
![Page 7: Standard Connection Details - Canam Bâtiments...CANAM Standard Connection Details REVISED AUGUST 2017](https://reader030.vdocuments.us/reader030/viewer/2022040121/5ec0a3f01aa58a26e72d491b/html5/thumbnails/7.jpg)
½" (13 mm) CLEAR MIN.
COLUMN-SEE PLAN
EE TYPICAL GAUGES
SHOE DEPTH SEE PLAN
3/4" 0 BOLTS @ 3" (76 mm) CIC
JOIST TYPE 2Y BOLTS NOT SUPPLIED BY CANAM
(CANAM PREFERRED BOLT DIA. FOR JOIST SEAT IS 3/4")
![Page 8: Standard Connection Details - Canam Bâtiments...CANAM Standard Connection Details REVISED AUGUST 2017](https://reader030.vdocuments.us/reader030/viewer/2022040121/5ec0a3f01aa58a26e72d491b/html5/thumbnails/8.jpg)
EE TYPICAL GAUGES "X" 0 BOLTS @5 1/2" (140 mm) CIC
SHOE DEPTH SEE PLAN
PL½" X6" X6" (NOT SUPPLIED BY CANAM)
DO NOT WELD BOTTOM CHORD
TO STABILIZER PLATE
JOIST TYPE BOLTS NOT SUPPLIED BY CANAM (CANAM PREFERRED BOLT DIA.
FOR JOIST SEAT IS 3/4")
![Page 9: Standard Connection Details - Canam Bâtiments...CANAM Standard Connection Details REVISED AUGUST 2017](https://reader030.vdocuments.us/reader030/viewer/2022040121/5ec0a3f01aa58a26e72d491b/html5/thumbnails/9.jpg)
(£_
I TYP. r
<TYP.
-��- EACH or ) 5 V 40
EACHSIDE SIDE
SHOE DEPTH SEE PLAN
\ ½" FACE OF WEB
(64 mm)
3/4" 0 BOLTS @ 3" (76 mm) CIC
JOIST TYPE 3X BOLTS NOT SUPPLIED BY CANAM
![Page 10: Standard Connection Details - Canam Bâtiments...CANAM Standard Connection Details REVISED AUGUST 2017](https://reader030.vdocuments.us/reader030/viewer/2022040121/5ec0a3f01aa58a26e72d491b/html5/thumbnails/10.jpg)
q_ I EE TYPICAL GAUGES
"X" 0 BOLTS@ 5 112" (140 mm) CIC
SHOE DEPTH SEE PLAN
\ .½" FACE OF WEB
(64 mm)
314" 0 BOLTS @ 3" (76 mm) CIC
JOIST TYPE BOLTS NOT SUPPLIED BY CANAM (CANAM PREFERRED BOLT DIA.
FOR JOIST SEAT IS 314")
3Y
![Page 11: Standard Connection Details - Canam Bâtiments...CANAM Standard Connection Details REVISED AUGUST 2017](https://reader030.vdocuments.us/reader030/viewer/2022040121/5ec0a3f01aa58a26e72d491b/html5/thumbnails/11.jpg)
EE TYPICAL GAUGES 1 "X" 0 BOLTS @5 1/2" (140 mm) CIC
v TCX � 1 SEE PLANT ,-----7i::::=t=====ls;::::=======:::j L ____ _
1"
(25 mm) ½" PLATE
(NOT SUPPLIED BY CANAM)
DO NOT WELD BOTTOM CHORD
TO STABILIZER PLATE
JOIST TYPE BOLTS NOT SUPPLIED BY CANAM(CANAM PREFERRED BOLT DIA.
FOR JOIST SEAT IS 3/4")
![Page 12: Standard Connection Details - Canam Bâtiments...CANAM Standard Connection Details REVISED AUGUST 2017](https://reader030.vdocuments.us/reader030/viewer/2022040121/5ec0a3f01aa58a26e72d491b/html5/thumbnails/12.jpg)
v TCX k
1 SEE PLA�
TYP. r <
TYP.}-------,c-----,-------{ EACH or
J 5 V 40 EACH
SIDE SIDE
SHOE DEPTH SEE PLAN
3/4" 0 BOLTS @ 3" (76 mm) CIC
JOIST TYPE 4X BOLTS NOT SUPPLIED BY CANAM
![Page 13: Standard Connection Details - Canam Bâtiments...CANAM Standard Connection Details REVISED AUGUST 2017](https://reader030.vdocuments.us/reader030/viewer/2022040121/5ec0a3f01aa58a26e72d491b/html5/thumbnails/13.jpg)
EE TYPICAL GAUGES 1 "X" 0 BOLTS @5 112" (140 mm) CIC
�I'. TCX k
1 SEE PLAN1 ,-----7,i==:1=:::;::=====is;=====� L ____ _
SHOE DEPTH SEE PLAN
314" 0 BOLTS @ 3" (76 mm) CIC
JOIST TYPE BOLTS NOT SUPPLIED BY CANAM (CANAM PREFERRED BOLT DIA.
FOR JOIST SEAT IS 314")
4Y
![Page 14: Standard Connection Details - Canam Bâtiments...CANAM Standard Connection Details REVISED AUGUST 2017](https://reader030.vdocuments.us/reader030/viewer/2022040121/5ec0a3f01aa58a26e72d491b/html5/thumbnails/14.jpg)
EE TYPICAL GAUGES "X" 0 BOLTS @5 1/2" (140 mm) CIC
1" (25 mm)
PL½" X6" X6"
�-__, t:::=::::;:::::===1 (NOT SUPPLIED BY CANAM)
1"
DO NOT WELD BOTTOM CHORD
TO STABILIZER PLATE
JOIST TYPE BOLTS NOT SUPPLIED BY CANAM (CANAM PREFERRED BOLT DIA.
FOR JOIST SEAT IS 3/4")
![Page 15: Standard Connection Details - Canam Bâtiments...CANAM Standard Connection Details REVISED AUGUST 2017](https://reader030.vdocuments.us/reader030/viewer/2022040121/5ec0a3f01aa58a26e72d491b/html5/thumbnails/15.jpg)
l I I
e TCX r 1 SEE PLAN'
TYP. r <
TYP. -��- EACH or
J 5 V 40 EACHSIDE SIDE
SHOE DEPTHSEE PLAN
3/4" 0 BOLTS @ 3" (76 mm) CIC
JOIST TYPE 5X BOLTS NOT SUPPLIED BY CANAM
![Page 16: Standard Connection Details - Canam Bâtiments...CANAM Standard Connection Details REVISED AUGUST 2017](https://reader030.vdocuments.us/reader030/viewer/2022040121/5ec0a3f01aa58a26e72d491b/html5/thumbnails/16.jpg)
EE TYPICAL GAUGES
"X" 0 BOLTS @5 112" (140 mm) CIC
SHOE DEPTH SEE PLAN
314" 0 BOLTS @ 3" (76 mm) CIC
JOIST TYPE BOLTS NOT SUPPLIED BY CANAM (CANAM PREFERRED BOLT DIA.
FOR JOIST SEAT IS 314")
SY
![Page 17: Standard Connection Details - Canam Bâtiments...CANAM Standard Connection Details REVISED AUGUST 2017](https://reader030.vdocuments.us/reader030/viewer/2022040121/5ec0a3f01aa58a26e72d491b/html5/thumbnails/17.jpg)
COLUMN-SEE PLAN
EE TYPICAL GAUGES "X" 0 BOLTS @5 1/2" (140 mm) CIC
SHOE DEPTH SEE PLAN
1" (25 mm)
PL½" X6" X6" (NOT SUPPLIED BY CANAM)
DO NOT WELD BOTTOM CHORD
TO STABILIZER PLATE
JOIST TYPE BOLTS NOT SUPPLIED BY CANAM (CANAM PREFERRED BOLT DIA.
FOR JOIST SEAT IS 3/4")
![Page 18: Standard Connection Details - Canam Bâtiments...CANAM Standard Connection Details REVISED AUGUST 2017](https://reader030.vdocuments.us/reader030/viewer/2022040121/5ec0a3f01aa58a26e72d491b/html5/thumbnails/18.jpg)
TYP. r <
TYP.
1112,, EACH or ,l 5 V 40 EACHSIDE SIDE
SHOE DEPTHSEE PLAN
2½" (64 mm)
3/4" 0 BOLTS@ 3" (76 mm) CIC
JOIST TYPE BOLTS NOT SUPPLIED BY CANAM 6X
![Page 19: Standard Connection Details - Canam Bâtiments...CANAM Standard Connection Details REVISED AUGUST 2017](https://reader030.vdocuments.us/reader030/viewer/2022040121/5ec0a3f01aa58a26e72d491b/html5/thumbnails/19.jpg)
EE TYPICAL GAUGES
"X" 0 BOLTS @5 112" (140 mm) CIC
COLUMN----i SEE PLAN 314" 0 BOLTS
@ 3" (76 mm) CIC
JOIST TYPE BOLTS NOT SUPPLIED BY CANAM (CANAM PREFERRED BOLT DIA.
FOR JOIST SEAT IS 314")
6Y
![Page 20: Standard Connection Details - Canam Bâtiments...CANAM Standard Connection Details REVISED AUGUST 2017](https://reader030.vdocuments.us/reader030/viewer/2022040121/5ec0a3f01aa58a26e72d491b/html5/thumbnails/20.jpg)
COLUMN-
SEE PLAN
SHOE DEPTH
SEE PLAN
JOIST TYPE 7Q
![Page 21: Standard Connection Details - Canam Bâtiments...CANAM Standard Connection Details REVISED AUGUST 2017](https://reader030.vdocuments.us/reader030/viewer/2022040121/5ec0a3f01aa58a26e72d491b/html5/thumbnails/21.jpg)
" 51 mm
"X" 0 BOLTS@ 5 1/2" (140 mm) CIC
SHOE DEPTH SEE PLAN
COLUMN-
SEE PLAN
JOIST TYPE BOLTS NOT SUPPLIED BY CANAM (CANAM PREFERRED BOLT DIA.
FOR JOIST SEAT IS 3/4")
* THIS SECTION ONLY APPLIES
TO WF 1 O" OR OVER
7T
![Page 22: Standard Connection Details - Canam Bâtiments...CANAM Standard Connection Details REVISED AUGUST 2017](https://reader030.vdocuments.us/reader030/viewer/2022040121/5ec0a3f01aa58a26e72d491b/html5/thumbnails/22.jpg)
"(51 mm) "X" 0 BOLTS @5 1/2" (140 mm) CIC
�==t=;==�========I L ____ _
COLUMN-SEE PLAN
SHOE DEPTH SEE PLAN
1"
(25 mm)
1" PL½"X6"X6" ---bi?f.-=-=---------:-
(25 mm) (NOT SUPPLIED BY CANAM)
DO NOT WELD BOTTOM CHORD
TO STABILIZER PLATE
JOIST TYPE BOLTS NOT SUPPLIED BY CANAM (CANAM PREFERRED BOLT DIA.
FOR JOIST SEAT IS 3/4")
* THIS SECTION ONLY APPLIES
TO WF 1 O" OR OVER
![Page 23: Standard Connection Details - Canam Bâtiments...CANAM Standard Connection Details REVISED AUGUST 2017](https://reader030.vdocuments.us/reader030/viewer/2022040121/5ec0a3f01aa58a26e72d491b/html5/thumbnails/23.jpg)
COLUMN-----i SEE PLAN
TYP. r <
TYP.--�1-11-2-,, EACH or ,.l
5 V 40 EACH
SIDE SIDE
SHOE DEPTH ½" SEE PLAN
---b151'--,....-=--------,, (13 mm)
2½" (64 mm)
3/4" 0 BOLTS @ 3" (76 mm) CIC
JOIST TYPE ?X BOLTS NOT SUPPLIED BY CANAM
![Page 24: Standard Connection Details - Canam Bâtiments...CANAM Standard Connection Details REVISED AUGUST 2017](https://reader030.vdocuments.us/reader030/viewer/2022040121/5ec0a3f01aa58a26e72d491b/html5/thumbnails/24.jpg)
" 51 mm
"X" 0 BOLTS@ 5 112" (140 mm) CIC
SHOE DEPTH
COLUMN-SEE PLAN
½" SEE PLAN -��
(13 mm)
2½" (64 mm)
314" 0 BOLTS @ 3" (76 mm) CIC
JOIST TYPE BOLTS NOT SUPPLIED BY CANAM (CANAM PREFERRED BOLT DIA.
FOR JOIST SEAT IS 314")
* THIS SECTION ONLY APPLIES
TO WF 1 O" OR OVER
?Y
![Page 25: Standard Connection Details - Canam Bâtiments...CANAM Standard Connection Details REVISED AUGUST 2017](https://reader030.vdocuments.us/reader030/viewer/2022040121/5ec0a3f01aa58a26e72d491b/html5/thumbnails/25.jpg)
TYP. r <
TYP. -��- EACH or
J 5 V 40 EACH
SIDE SIDE
COLUMN-SEE PLAN
JOIST TYPE
* IF SEAT ANGLE IS GREATER
THAN L4 X 4 ADVISE CANAM
8Q
![Page 26: Standard Connection Details - Canam Bâtiments...CANAM Standard Connection Details REVISED AUGUST 2017](https://reader030.vdocuments.us/reader030/viewer/2022040121/5ec0a3f01aa58a26e72d491b/html5/thumbnails/26.jpg)
½" 64 mm "X" 0 BOLTS@ 5 1/2" (140 mm) CIC
COLUMN-
SEE PLAN
JOIST TYPE BOLTS NOT SUPPLIED BY CANAM (CANAM PREFERRED BOLT DIA.
FOR JOIST SEAT IS 3/4")
* IF SEAT ANGLE IS GREATER
THAN L4 X 4 ADVISE CANAM
BT
![Page 27: Standard Connection Details - Canam Bâtiments...CANAM Standard Connection Details REVISED AUGUST 2017](https://reader030.vdocuments.us/reader030/viewer/2022040121/5ec0a3f01aa58a26e72d491b/html5/thumbnails/27.jpg)
COLUMN-SEE PLAN
½" 64 mm "X" 0 BOLTS @5 1/2" (140 mm) CIC
PL½" X6" X6" (NOT SUPPLIED BY CANAM)
DO NOT WELD BOTTOM CHORD
TO STABILIZER PLATE
JOIST TYPE BOLTS NOT SUPPLIED BY CANAM (CANAM PREFERRED BOLT DIA.
FOR JOIST SEAT IS 3/4")
* IF SEAT ANGLE IS GREATER
THAN L4 X 4 ADVISE CANAM
![Page 28: Standard Connection Details - Canam Bâtiments...CANAM Standard Connection Details REVISED AUGUST 2017](https://reader030.vdocuments.us/reader030/viewer/2022040121/5ec0a3f01aa58a26e72d491b/html5/thumbnails/28.jpg)
TYP. r <
TYP. -��- EACH or
J 5 V 40 EACH
SIDE SIDE
COLUMN-SEE PLAN 3/4" 0 BOLTS
@ 3" (76 mm) CIC
JOIST TYPE BOLTS NOT SUPPLIED BY CANAM * IF SEAT ANGLE IS GREATER
THAN L4 X 4 ADVISE CANAM
BX
![Page 29: Standard Connection Details - Canam Bâtiments...CANAM Standard Connection Details REVISED AUGUST 2017](https://reader030.vdocuments.us/reader030/viewer/2022040121/5ec0a3f01aa58a26e72d491b/html5/thumbnails/29.jpg)
½" 64 mm "X" 0 BOLTS@ 5 112" (140 mm) CIC
COLUMN-SEE PLAN
314" 0 BOLTS @ 3" (76 mm) CIC
JOIST TYPE BOLTS NOT SUPPLIED BY CANAM (CANAM PREFERRED BOLT DIA.
FOR JOIST SEAT IS 314")
* IF SEAT ANGLE IS GREATER
THAN L4 X 4 ADVISE CANAM
BY
![Page 30: Standard Connection Details - Canam Bâtiments...CANAM Standard Connection Details REVISED AUGUST 2017](https://reader030.vdocuments.us/reader030/viewer/2022040121/5ec0a3f01aa58a26e72d491b/html5/thumbnails/30.jpg)
TYP. r <
TYP. -��- EACH or )
5 V 40EACH
SIDE SIDE
,------�=-=t=.=====is=====� L:f ___ l
COLUMN-SEE PLAN
JOIST TYPE * COLUMN ELEVATION MUST BE 9Q
LOWER THAN ANGLE ELEVATION ,.______,
** IF SEAT ANGLE IS GREATER
THAN L4 X 4 ADVISE CANAM
![Page 31: Standard Connection Details - Canam Bâtiments...CANAM Standard Connection Details REVISED AUGUST 2017](https://reader030.vdocuments.us/reader030/viewer/2022040121/5ec0a3f01aa58a26e72d491b/html5/thumbnails/31.jpg)
2½" (64 mm)
"X" 0 BOLTS@ 5 1/2" (140 mm) CIC
,------�:;::!::::=:t===::ls;:::========:j L:f ___ l
COLUMN-SEE PLAN
JOIST TYPE BOLTS NOT SUPPLIED BY CANAM 9T (CANAM PREFERRED BOLT DIA.
FOR JOIST SEAT IS 3/4") * COLUMN ELEVATION MUST BE
LOWER THAN ANGLE ELEVATION
** IF SEAT ANGLE IS GREATER
THAN L4 X 4 ADVISE CANAM
![Page 32: Standard Connection Details - Canam Bâtiments...CANAM Standard Connection Details REVISED AUGUST 2017](https://reader030.vdocuments.us/reader030/viewer/2022040121/5ec0a3f01aa58a26e72d491b/html5/thumbnails/32.jpg)
½" 64 mm "X" 0 BOLTS@ 5 1/2" (140 mm) CIC
,------�:;::l::::=:!:===::ls;::::========:j
L:f ___ l
COLUMN-SEE PLAN
I
I
PL½" X6" X6" (NOT SUPPLIED BY CANAM)
DO NOT WELD BOTTOM CHORD
TO STABILIZER PLATE
JOIST TYPE BOLTS NOT SUPPLIED BY CANAM (CANAM PREFERRED BOLT DIA.
FOR JOIST SEAT IS 3/4")* COLUMN ELEVATION MUST BE
LOWER THAN ANGLE ELEVATION
** IF SEAT ANGLE IS GREATER
THAN L4 X 4 ADVISE CANAM
![Page 33: Standard Connection Details - Canam Bâtiments...CANAM Standard Connection Details REVISED AUGUST 2017](https://reader030.vdocuments.us/reader030/viewer/2022040121/5ec0a3f01aa58a26e72d491b/html5/thumbnails/33.jpg)
TYP. r <
TYP.
--�1-1-12-,, EACH or)5 V 40
EACH SIDE SIDE
,------�==l==;=.==::ls;:::========:j L:f ___ l
COLUMN-SEE PLAN 3/4" 0 BOLTS
@ 3" (76 mm) CIC
JOIST TYPE BOLTS NOT SUPPLIED BY CANAM 9 X
* COLUMN ELEVATION MUST BE ,.______, LOWER THAN ANGLE ELEVATION
** IF SEAT ANGLE IS GREATER
THAN L4 X 4 ADVISE CANAM
![Page 34: Standard Connection Details - Canam Bâtiments...CANAM Standard Connection Details REVISED AUGUST 2017](https://reader030.vdocuments.us/reader030/viewer/2022040121/5ec0a3f01aa58a26e72d491b/html5/thumbnails/34.jpg)
2½" (64 mm)
"X" 0 BOLTS@ 5 112" (140 mm) CIC
,------�:;::!::::=:t===::ls;:::========:j L:f ___ l
COLUMN-SEE PLAN 314" 0 BOLTS
@ 3" (76 mm) CIC
JOIST TYPE BOLTS NOT SUPPLIED BY CANAM 9 y (CANAM PREFERRED BOLT DIA.
FOR JOIST SEAT IS 314")
* COLUMN ELEVATION MUST BE
LOWER THAN ANGLE ELEVATION
** IF SEAT ANGLE IS GREATER
THAN L4 X 4 ADVISE CANAM
![Page 35: Standard Connection Details - Canam Bâtiments...CANAM Standard Connection Details REVISED AUGUST 2017](https://reader030.vdocuments.us/reader030/viewer/2022040121/5ec0a3f01aa58a26e72d491b/html5/thumbnails/35.jpg)
TYP. r (
TYP.
-3-/16-"�1-1- /2-" EACH or J 5 V 40 EACH
SIDE SIDE
JOIST TYPE ** IF SEAT ANGLE IS GREATER
THAN L4 X 4 ADVISE CANAM
![Page 36: Standard Connection Details - Canam Bâtiments...CANAM Standard Connection Details REVISED AUGUST 2017](https://reader030.vdocuments.us/reader030/viewer/2022040121/5ec0a3f01aa58a26e72d491b/html5/thumbnails/36.jpg)
½" 64 mm "X" 0 BOLTS@ 5 1/2" (140 mm) CIC
JOIST TYPE BOLTS NOT SUPPLIED BY CANAM (CANAM PREFERRED BOLT DIA.
FOR JOIST SEAT IS 3/4")
** IF SEAT ANGLE IS GREATER
THAN L4 X 4 ADVISE CANAM
![Page 37: Standard Connection Details - Canam Bâtiments...CANAM Standard Connection Details REVISED AUGUST 2017](https://reader030.vdocuments.us/reader030/viewer/2022040121/5ec0a3f01aa58a26e72d491b/html5/thumbnails/37.jpg)
½" 64 mm "X" 0 BOLTS@ 5 1/2" (140 mm) CIC
PL½" X6" X6" (NOT SUPPLIED BY CANAM)
DO NOT WELD BOTTOM CHORD
TO STABILIZER PLATE
JOIST TYPE BOLTS NOT SUPPLIED BY CANAM (CANAM PREFERRED BOLT DIA.
FOR JOIST SEAT IS 3/4")
** IF SEAT ANGLE IS GREATER
THAN L4 X 4 ADVISE CANAM
![Page 38: Standard Connection Details - Canam Bâtiments...CANAM Standard Connection Details REVISED AUGUST 2017](https://reader030.vdocuments.us/reader030/viewer/2022040121/5ec0a3f01aa58a26e72d491b/html5/thumbnails/38.jpg)
TYP. r <
TYP. -��----< EACH or
J 5 V 40 EACH
SIDE SIDE
3/4" 0 BOLTS @ 3" (76 mm) CIC
JOIST TYPE BOLTS NOT SUPPLIED BY CANAM
** IF SEAT ANGLE IS GREATER
THAN L4 X 4 ADVISE CANAM
![Page 39: Standard Connection Details - Canam Bâtiments...CANAM Standard Connection Details REVISED AUGUST 2017](https://reader030.vdocuments.us/reader030/viewer/2022040121/5ec0a3f01aa58a26e72d491b/html5/thumbnails/39.jpg)
½" 64 mm "X" 0 BOLTS @5 112" (140 mm) CIC
314" 0 BOLTS @ 3" (76 mm) CIC
JOIST TYPE BOLTS NOT SUPPLIED BY CANAM (CANAM PREFERRED BOLT DIA.
FOR JOIST SEAT IS 314")
** IF SEAT ANGLE IS GREATER
THAN L4 X 4 ADVISE CANAM
![Page 40: Standard Connection Details - Canam Bâtiments...CANAM Standard Connection Details REVISED AUGUST 2017](https://reader030.vdocuments.us/reader030/viewer/2022040121/5ec0a3f01aa58a26e72d491b/html5/thumbnails/40.jpg)
COLUMN-SEE PLAN
½" 64 mm "X" 0 BOLTS@ 5 1/2" (140 mm) C/C
PL½" X6" X6" (NOT SUPPLIED BY CANAM)
DO NOT WELD BOTTOM CHORD
TO STABILIZER PLATE
JOIST TYPE BOLTS NOT SUPPLIED BY CANAM (CANAM PREFERRED BOLT DIA.
FOR JOIST SEAT IS 3/4") ** IF SEAT ANGLE IS GREATER
THAN L4 X 4 ADVISE CANAM
![Page 41: Standard Connection Details - Canam Bâtiments...CANAM Standard Connection Details REVISED AUGUST 2017](https://reader030.vdocuments.us/reader030/viewer/2022040121/5ec0a3f01aa58a26e72d491b/html5/thumbnails/41.jpg)
COLUMN-SEE PLAN
TYP. r (
TYP. --�1-11-2-,, EACH or
ls V 40 EACHSIDE SIDE
3/4" 0 BOLTS @ 3" (76 mm) CIC
JOIST TYPE BOLTS NOT SUPPLIED BY CANAM
** IF SEAT ANGLE IS GREATER
THAN L4 X 4 ADVISE CANAM
![Page 42: Standard Connection Details - Canam Bâtiments...CANAM Standard Connection Details REVISED AUGUST 2017](https://reader030.vdocuments.us/reader030/viewer/2022040121/5ec0a3f01aa58a26e72d491b/html5/thumbnails/42.jpg)
COLUMN-SEE PLAN
½" 64 mm "X" 0 BOLTS @5 112" (140 mm) CIC
314" 0 BOLTS @ 3" (76 mm) CIC
JOIST TYPE BOLTS NOT SUPPLIED BY CANAM (CANAM PREFERRED BOLT DIA.
FOR JOIST SEAT IS 314")
** IF SEAT ANGLE IS GREATER
THAN L4 X 4 ADVISE CANAM
![Page 43: Standard Connection Details - Canam Bâtiments...CANAM Standard Connection Details REVISED AUGUST 2017](https://reader030.vdocuments.us/reader030/viewer/2022040121/5ec0a3f01aa58a26e72d491b/html5/thumbnails/43.jpg)
COLUMN-SEE PLAN
TYP. r <
TYP. -��- EACH or
l 5 V 40 EACHSIDE SIDE
JOIST TYPE ** IF SEAT ANGLE IS GREATER
THAN L4 X 4 ADVISE CANAM
![Page 44: Standard Connection Details - Canam Bâtiments...CANAM Standard Connection Details REVISED AUGUST 2017](https://reader030.vdocuments.us/reader030/viewer/2022040121/5ec0a3f01aa58a26e72d491b/html5/thumbnails/44.jpg)
COLUMN-
SEE PLAN
2 ½" (64 mm) FROM FACE OF WEB "X" 0 BOLTS @5 1/2" (140 mm) C/C
JOIST TYPE BOLTS NOT SUPPLIED BY CANAM (CANAM PREFERRED BOLT DIA.
FOR JOIST SEAT IS 3/4")
* THIS SECTION ONLY APPLIES
TO WF 1 O" OR OVER
** IF SEAT ANGLE IS GREATER
THAN L4 X 4 ADVISE CANAM
![Page 45: Standard Connection Details - Canam Bâtiments...CANAM Standard Connection Details REVISED AUGUST 2017](https://reader030.vdocuments.us/reader030/viewer/2022040121/5ec0a3f01aa58a26e72d491b/html5/thumbnails/45.jpg)
COLUMN-
SEE PLAN
21/2" 64 mm FROM FACE OF WEB
"X" 0 BOLTS @5 1/2" (140 mm) C/C
½" PLATE (NOT SUPPLIED BY CANAM)
DO NOT WELD BOTTOM CHORD
TO STABILIZER PLATE
JOIST TYPE BOLTS NOT SUPPLIED BY CANAM (CANAM PREFERRED BOLT DIA.
FOR JOIST SEAT IS 3/4")
* THIS SECTION ONLY APPLIES
TO WF 1 O" OR OVER
** IF SEAT ANGLE IS GREATER
THAN L4 X 4 ADVISE CANAM
![Page 46: Standard Connection Details - Canam Bâtiments...CANAM Standard Connection Details REVISED AUGUST 2017](https://reader030.vdocuments.us/reader030/viewer/2022040121/5ec0a3f01aa58a26e72d491b/html5/thumbnails/46.jpg)
COLUMN-SEE PLAN
SHOE DEPTH SEE PLAN
3/4" 0 BOLTS @ 3" (76 mm) CIC
JOIST TYPE BOLTS NOT SUPPLIED BY CANAM
** IF SEAT ANGLE IS GREATER
THAN L4 X 4 ADVISE CANAM
![Page 47: Standard Connection Details - Canam Bâtiments...CANAM Standard Connection Details REVISED AUGUST 2017](https://reader030.vdocuments.us/reader030/viewer/2022040121/5ec0a3f01aa58a26e72d491b/html5/thumbnails/47.jpg)
COLUMN-SEE PLAN
2 1/2" 64 mm FROM FACE OF WEB "X" 0 BOLTS @5 1/2" (140 mm) C/C
SHOE DEPTH SEE PLAN
2½" (64 mm)
3/4" 0 BOLTS @ 3" (76 mm) CIC
JOIST TYPE BOLTS NOT SUPPLIED BY CANAM (CANAM PREFERRED BOLT DIA.
FOR JOIST SEAT IS 3/4")
* THIS SECTION ONLY APPLIES
TO WF 1 O" OR OVER
** IF SEAT ANGLE IS GREATER
THAN L4 X 4 ADVISE CANAM
![Page 48: Standard Connection Details - Canam Bâtiments...CANAM Standard Connection Details REVISED AUGUST 2017](https://reader030.vdocuments.us/reader030/viewer/2022040121/5ec0a3f01aa58a26e72d491b/html5/thumbnails/48.jpg)
COLUMN-
SEE PLAN
CE.
I 1 ½" (38 mm) "X" 0 BOLTS@ 5 1/2" (140 mm) CIC
JOIST TYPE BOLTS NOT SUPPLIED BY CANAM (CANAM PREFERRED BOLT DIA.
FOR JOIST SEAT IS 3/4")
* THIS SECTION APPLIES TO
ALL HSS AND WF 811
OR LESS
![Page 49: Standard Connection Details - Canam Bâtiments...CANAM Standard Connection Details REVISED AUGUST 2017](https://reader030.vdocuments.us/reader030/viewer/2022040121/5ec0a3f01aa58a26e72d491b/html5/thumbnails/49.jpg)
COLUMN-SEE PLAN
CE.
I 1 ½" (38 mm) "X" 0 BOLTS@ 5 1/2" (140 mm) CIC
1" (25 mm)
PL½" X6" X6" (NOT SUPPLIED BY CANAM)
DO NOT WELD BOTTOM CHORD
TO STABILIZER PLATE
JOIST TYPE BOLTS NOT SUPPLIED BY CANAM (CANAM PREFERRED BOLT DIA.
FOR JOIST SEAT IS 3/4")
* THIS SECTION APPLIES TO
ALL HSS AND WF 811
OR LESS
![Page 50: Standard Connection Details - Canam Bâtiments...CANAM Standard Connection Details REVISED AUGUST 2017](https://reader030.vdocuments.us/reader030/viewer/2022040121/5ec0a3f01aa58a26e72d491b/html5/thumbnails/50.jpg)
COLUMN --
SEE PLAN
l
I 1 ½" 38 mm "X" 0 BOLTS@ 5 112" (140 mm) CIC
314" 0 BOLTS
@ 3" (76 mm) CIC
JOIST TYPE BOLTS NOT SUPPLIED BY CANAM (CANAM PREFERRED BOLT DIA.
FOR JOIST SEAT IS 314")
* THIS SECTION APPLIES TO
ALL HSS AND WF 811
OR LESS
![Page 51: Standard Connection Details - Canam Bâtiments...CANAM Standard Connection Details REVISED AUGUST 2017](https://reader030.vdocuments.us/reader030/viewer/2022040121/5ec0a3f01aa58a26e72d491b/html5/thumbnails/51.jpg)
COLUMN-SEE PLAN
ID Ill
TYP. r <
TYP. J---------.�---:-:=::-"\ EACH or f--.---�- EACH
1 1/2" SIDE J 5 V 40 SIDE
JOIST TYPE
![Page 52: Standard Connection Details - Canam Bâtiments...CANAM Standard Connection Details REVISED AUGUST 2017](https://reader030.vdocuments.us/reader030/viewer/2022040121/5ec0a3f01aa58a26e72d491b/html5/thumbnails/52.jpg)
COLUMN-�
SEE PLAN
JO BE COORDINATED WITH CANAM
"X" 0 BOLTS @5 1/2" (140 mm) CIC
ID Ill JOIST TYPE
BOLTS SUPPLIED BY CANAM (CANAM PREFERRED BOLT DIA.
FOR JOIST SEAT IS 3/4")
![Page 53: Standard Connection Details - Canam Bâtiments...CANAM Standard Connection Details REVISED AUGUST 2017](https://reader030.vdocuments.us/reader030/viewer/2022040121/5ec0a3f01aa58a26e72d491b/html5/thumbnails/53.jpg)
COLUMN-SEE PLAN
TO BE COORDINATED WITH CANAM
"X" 0 BOLTS @5 1/2" (140 mm) CIC
ID Ill
PL½" X6" X6" (NOT SUPPLIED BY CANAM)
DO NOT WELD BOTTOM CHORD
TO STABILIZER PLATE
JOIST TYPE BOLTS SUPPLIED BY CANAM
(CANAM PREFERRED BOLT DIA. FOR JOIST SEAT IS 3/4")
![Page 54: Standard Connection Details - Canam Bâtiments...CANAM Standard Connection Details REVISED AUGUST 2017](https://reader030.vdocuments.us/reader030/viewer/2022040121/5ec0a3f01aa58a26e72d491b/html5/thumbnails/54.jpg)
CE.
I TYP. r
<TYP.
--�1-1-12-,, EACH or J 5 V 40
EACHSIDE SIDE
SHOE DEPTH SEE PLAN
COLUMN--SEE PLAN
m Ill
3/4" 0 BOLTS @ 3" (76 mm) CIC
JOIST TYPE BOLTS NOT SUPPLIED BY CANAM
![Page 55: Standard Connection Details - Canam Bâtiments...CANAM Standard Connection Details REVISED AUGUST 2017](https://reader030.vdocuments.us/reader030/viewer/2022040121/5ec0a3f01aa58a26e72d491b/html5/thumbnails/55.jpg)
JO BE COORDINATED WITH CANAM
"X" 0 BOLTS @5 112" (140 mm) CIC
SHOE DEPTH SEE PLAN
COLUMN--
SEE PLAN
m Ill
314" 0 BOLTS
@ 3" (76 mm) CIC
JOIST TYPE SEAT BOLTS SUPPLIED BY CANAM
BOTTOM CHORD TIE PLATE BOLTS NOT SUPPLIED BY CANAM
(CANAM PREFERRED BOLT DIA. FOR JOIST SEAT IS 314")
![Page 56: Standard Connection Details - Canam Bâtiments...CANAM Standard Connection Details REVISED AUGUST 2017](https://reader030.vdocuments.us/reader030/viewer/2022040121/5ec0a3f01aa58a26e72d491b/html5/thumbnails/56.jpg)
TCX SEE PLAN
EACH r <
EACH!-----------.-,--� SIDE or 1----.---
V,---------< SIDE 3/16" 1 1/2" OF BC J 5 4
o OF BC
NOTE:CONFIGURATIONMAY VARY
JOIST TYPE
![Page 57: Standard Connection Details - Canam Bâtiments...CANAM Standard Connection Details REVISED AUGUST 2017](https://reader030.vdocuments.us/reader030/viewer/2022040121/5ec0a3f01aa58a26e72d491b/html5/thumbnails/57.jpg)
EE TYPICAL GAUGES
TCX SEE PLAN
"X" 0 BOLTS (C/C DIMENSION TO BE COORDINATED WITH CANAM
JOIST TYPE BOLTS NOT SUPPLIED BY CANAM (CANAM PREFERRED BOLT DIA.
FOR JOIST SEAT IS 3/4")
NOTE:
CONFIGURATION MAY VARY
![Page 58: Standard Connection Details - Canam Bâtiments...CANAM Standard Connection Details REVISED AUGUST 2017](https://reader030.vdocuments.us/reader030/viewer/2022040121/5ec0a3f01aa58a26e72d491b/html5/thumbnails/58.jpg)
TCX SEE PLAN
COLUMN-SEE PLAN
JOIST TYPE
EAC H r <��D
CEH
11/2" �l
��c or l 5 V 40 OF BC
NOTE: CON FIGURATIONMAY VARY
![Page 59: Standard Connection Details - Canam Bâtiments...CANAM Standard Connection Details REVISED AUGUST 2017](https://reader030.vdocuments.us/reader030/viewer/2022040121/5ec0a3f01aa58a26e72d491b/html5/thumbnails/59.jpg)
TCX SEE PLAN
COLUMN-
SEE PLAN
11/2" 38 mm
"X" 0 BOLTS (C/C DIMENSION TO BE COORDINATED WITH CANAM
NOTE:
CONFIGURATION MAY VARY
JOIST TYPE BOLTS NOT SUPPLIED BY CANAM (CANAM PREFERRED BOLT DIA.
FOR JOIST SEAT IS 3/4")
![Page 60: Standard Connection Details - Canam Bâtiments...CANAM Standard Connection Details REVISED AUGUST 2017](https://reader030.vdocuments.us/reader030/viewer/2022040121/5ec0a3f01aa58a26e72d491b/html5/thumbnails/60.jpg)
TCX
SEE PLAN
EOS
SEE PLAN
BEARING PLATE
NOT SUPPLIED
BYCANAM
JOIST TYPE
![Page 61: Standard Connection Details - Canam Bâtiments...CANAM Standard Connection Details REVISED AUGUST 2017](https://reader030.vdocuments.us/reader030/viewer/2022040121/5ec0a3f01aa58a26e72d491b/html5/thumbnails/61.jpg)
EOS
SEE PLAN
BEARING PLATE
NOT SUPPLIED
BYCANAM
JOIST TYPE
![Page 62: Standard Connection Details - Canam Bâtiments...CANAM Standard Connection Details REVISED AUGUST 2017](https://reader030.vdocuments.us/reader030/viewer/2022040121/5ec0a3f01aa58a26e72d491b/html5/thumbnails/62.jpg)
ANGLE-+-'
NOT SUPPLIED
BYCANAM
JOIST TYPE
** IF SEAT ANGLE IS GREATER
THAN L4 X 4 ADVISE CANAM
![Page 63: Standard Connection Details - Canam Bâtiments...CANAM Standard Connection Details REVISED AUGUST 2017](https://reader030.vdocuments.us/reader030/viewer/2022040121/5ec0a3f01aa58a26e72d491b/html5/thumbnails/63.jpg)
ANGLE ------t---'
NOT SUPPLIED
BYCANAM
½" 64 mm "X" 0 BOLTS @5 1/2" (140 mm) CIC
JOIST TYPE BOLTS NOT SUPPLIED BY CANAM (CANAM PREFERRED BOLT DIA.
FOR JOIST SEAT IS 3/4")
** IF SEAT ANGLE IS GREATER
THAN L4 X 4 ADVISE CANAM
![Page 64: Standard Connection Details - Canam Bâtiments...CANAM Standard Connection Details REVISED AUGUST 2017](https://reader030.vdocuments.us/reader030/viewer/2022040121/5ec0a3f01aa58a26e72d491b/html5/thumbnails/64.jpg)
EOS SEE PLAN
BEARING PLATENOT SUPPLIED
BYCANAM
H r EACH EAC L__�----1<SIDE L--------r--,---------\ SI DE or J 5 V 40 0 F BCOFBC
NOTE: CONFIGURATIONMAY VARY
JOIST TYPE
![Page 65: Standard Connection Details - Canam Bâtiments...CANAM Standard Connection Details REVISED AUGUST 2017](https://reader030.vdocuments.us/reader030/viewer/2022040121/5ec0a3f01aa58a26e72d491b/html5/thumbnails/65.jpg)
TCX
SEE PLAN
BEARING PLATE
NOT SUPPLIED
BYCANAM
NOTE:
CONFIGURATION
MAY VARY
JOIST TYPE
![Page 66: Standard Connection Details - Canam Bâtiments...CANAM Standard Connection Details REVISED AUGUST 2017](https://reader030.vdocuments.us/reader030/viewer/2022040121/5ec0a3f01aa58a26e72d491b/html5/thumbnails/66.jpg)
2¾" 2¾"
(70 mm) (70 mm)
5½" (140 mm
HOLES C/C FOR SHOE ALWAYS GIVEN
PERPENDICULAR TO JOIST
IF THIS DETAIL REQUIRED FOR GIRDER, USE 6" (152 mm) FOR C/C OF HOLES AT SHOE.
JOIST TYPE BOLTS NOT SUPPLIED BY CANAM (CANAM PREFERRED BOLT DIA.
FOR JOIST SEAT IS 3/4")
![Page 67: Standard Connection Details - Canam Bâtiments...CANAM Standard Connection Details REVISED AUGUST 2017](https://reader030.vdocuments.us/reader030/viewer/2022040121/5ec0a3f01aa58a26e72d491b/html5/thumbnails/67.jpg)
1 ½" 1 ½"
(38 mm) (38 mm)
HOLES FOR BOTTOM CHORD PLATE ALWAYS GIVEN PERPENDICULAR
TO JOIST / GIRDER
@ 0::-w
c[ � a. 0=> Ien en z => 00 -wen I z 1-w >� III0
2¾"
(70 mm) 5½"
(140 mm
2¾"
(70 mm)
HOLES C/C FOR SHOE ALWAYS GIVEN
PERPENDICULAR TO JOIST
IF THIS DETAIL REQUIRED FOR GIRDER, USE 6" (152 mm) FOR C/C OF HOLES AT SHOE.
JOIST TYPE BOLTS NOT SUPPLIED BY CANAM (CANAM PREFERRED BOLT DIA.
FOR JOIST SEAT IS 3/4")
![Page 68: Standard Connection Details - Canam Bâtiments...CANAM Standard Connection Details REVISED AUGUST 2017](https://reader030.vdocuments.us/reader030/viewer/2022040121/5ec0a3f01aa58a26e72d491b/html5/thumbnails/68.jpg)
A
A
/
/
0 w 0::-w ...Ja.. ...::: 1
/
2" min. (51 mm)
..::: 1 ½"
� � (�3-a---'
m=---m-)-+------,1<--+--,1<-+------,-,,,____,=----en en
FOR BOTTOM CHORD CONNECTION
� � 2 ¾" 2 ¾" � FOR SHOE CONNECTION I en � -(7_0_m�m--+-----+---#-(-70�m�m-) z 1-w >-�
ID 0
IF THIS DETAIL REQUIRED FOR GIRDER, USE 6" (152 mm) FOR C/C OF HOLES AT SHOE.
JOIST TYPE BOLTS NOT SUPPLIED BY CANAM
(CANAM PREFERRED BOLT DIA. FOR JOIST SEAT IS 3/4")
q_ J
I I'
I I
I
I I I
I I I
II
I I I
I
I
111
111
1 11 1LIi
I
J /
, /I
SECTION A-A
![Page 69: Standard Connection Details - Canam Bâtiments...CANAM Standard Connection Details REVISED AUGUST 2017](https://reader030.vdocuments.us/reader030/viewer/2022040121/5ec0a3f01aa58a26e72d491b/html5/thumbnails/69.jpg)
A
A
/
0 w 0::-w c[ � a.. 0:::J Ien en
/
/
/
2" min. (51 mm)
� � 2 ¾" 2 ¾" � FOR SHOE CONNECTION I en � -(7_0_m�m---#---+--------.1(�7-0-m�m-) z 1-w >-�
ID 0
IF THIS DETAIL REQUIRED FOR GIRDER, USE 6" (152 mm) FOR C/C OF HOLES AT SHOE.
JOIST TYPE BOLTS NOT SUPPLIED BY CANAM
(CANAM PREFERRED BOLT DIA. FOR JOIST SEAT IS 3/4")
q_ J
I I'
I I I
I I I
I II
I I I I I I I II
111
111
1 11 1LIi
I J
/
, /I
SECTION A-A
![Page 70: Standard Connection Details - Canam Bâtiments...CANAM Standard Connection Details REVISED AUGUST 2017](https://reader030.vdocuments.us/reader030/viewer/2022040121/5ec0a3f01aa58a26e72d491b/html5/thumbnails/70.jpg)
EE TYPICAL GAUGES 3/4" 0 BOLTS@ 6" (152 mm) CIC
v TCX � l SEE PLAN'I
,-----�����===�=============�
L ____ 7 I ���
I
7 1/2" (190 mm)
1" (25 mm)
¼" PLATE (NOT SUPPLIED BY CANAM)
DO NOT WELD BOTTOM CHORD
TO STABILIZER PLATE
GIRDER TYPE BOLTS NOT SUPPLIED BY CANAM
![Page 71: Standard Connection Details - Canam Bâtiments...CANAM Standard Connection Details REVISED AUGUST 2017](https://reader030.vdocuments.us/reader030/viewer/2022040121/5ec0a3f01aa58a26e72d491b/html5/thumbnails/71.jpg)
EE TYPICAL GAUGES 314" 0 BOLTS @ 6" (152 mm) CIC
314" 0 BOLTS @ 3" (76 mm) CIC
GIRDER TYPE BOLTS NOT SUPPLIED BY CANAM
![Page 72: Standard Connection Details - Canam Bâtiments...CANAM Standard Connection Details REVISED AUGUST 2017](https://reader030.vdocuments.us/reader030/viewer/2022040121/5ec0a3f01aa58a26e72d491b/html5/thumbnails/72.jpg)
EE TYPICAL GAUGES 3/4" 0 BOLTS @ 6" (152 mm) CIC
v TCX � l SEE PLANT
,-----�:����===��=============� 1
I 7 1/2" L - - - - 7 ( 190 mm) ------r--------.------1
���:\-�&
I
1" (25 mm) TYP.
PL¼" X6" (NOT SUPPLIED BY CANAM)
DO NOT WELD BOTTOM CHORD
TO STABILIZER PLATE
GIRDER TYPE BOLTS NOT SUPPLIED BY CANAM
** TO CALCULATE PLATE DIM. REFER TO CHORD SIZE IN GIRDER DESIGN
![Page 73: Standard Connection Details - Canam Bâtiments...CANAM Standard Connection Details REVISED AUGUST 2017](https://reader030.vdocuments.us/reader030/viewer/2022040121/5ec0a3f01aa58a26e72d491b/html5/thumbnails/73.jpg)
EE TYPICAL GAUGES 314" 0 BOLTS @ 6" (152 mm) CIC
1/ TCX ;;-J
I SEE PLA�
,-----���=====is-===============1
L ____ 7 I 7 112" (190 mm)
c=:::h-Jqs==1-
½" (64 mm)
314" 0 BOLTS @ 3" (76 mm) CIC
GIRDER TYPE BOLTS NOT SUPPLIED BY CANAM
![Page 74: Standard Connection Details - Canam Bâtiments...CANAM Standard Connection Details REVISED AUGUST 2017](https://reader030.vdocuments.us/reader030/viewer/2022040121/5ec0a3f01aa58a26e72d491b/html5/thumbnails/74.jpg)
} " 51 mm
3/4" 0 BOLTS @ 6" (152 mm) CIC
TCX SEE PLA
i - - - - -,��=I=+-=-:::::;-_-_-_----;..----_-_-_-_-_-_-_-_-_-_-_-_-_------i---1
I
I
L ____ 7
COLUMN-SEE PLAN
111
I I
7 1/2" (190 mm)
1" (25 mm) TYP.
) PL½"X6"
(NOT SUPPLIED BY CANAM)
DO NOT WELD BOTTOM CHORD
TO STABILIZER PLATE
GIRDER TYPE BOLTS NOT SUPPLIED BY CANAM
* THIS SECTION ONLY APPLIES
TO WF 1 O" OR OVER
** TO CALCULATE PLATE DIM. REFER TO CHORD SIZE IN GIRDER DESIGN
![Page 75: Standard Connection Details - Canam Bâtiments...CANAM Standard Connection Details REVISED AUGUST 2017](https://reader030.vdocuments.us/reader030/viewer/2022040121/5ec0a3f01aa58a26e72d491b/html5/thumbnails/75.jpg)
r "51 mm 314" 0 BOLTS @6" (152 mm) CIC
TCX SEE PLA
:-----1i��==
�.:::==
1=1=n= .. ========
� L ____ 7 1 (190 mm)
COLUMN-SEE PLAN
½" (13 mm)__
2½" (64 mm)
314" 0 BOLTS @ 3" (76 mm) CIC
DO NOT WELD BOTTOM CHORD
TO STABILIZER PLATE
GIRDER TYPE BOLTS NOT SUPPLIED BY CANAM
* THIS SECTION ONLY APPLIES
TO WF 1 O" OR OVER
![Page 76: Standard Connection Details - Canam Bâtiments...CANAM Standard Connection Details REVISED AUGUST 2017](https://reader030.vdocuments.us/reader030/viewer/2022040121/5ec0a3f01aa58a26e72d491b/html5/thumbnails/76.jpg)
TCX SEE PLAN
COLUMN-� SEE PLAN
ill mI
1 1/2" 38 mm 3/4" 0 BOLTS @6" (152 mm) CIC
1" (25 mm) TYP.
) PL½"X6"
(NOT SUPPLIED BY CANAM)
DO NOT WELD BOTTOM CHORD
TO STABILIZER PLATE
GIRDER TYPE BOLTS NOT SUPPLIED BY CANAM
* THIS SECTION APPLIES TO
ALL HSS AND WF 811
OR LESS
** TO CALCULATE PLATE DIM. REFER TO CHORD SIZE IN GIRDER DESIGN
![Page 77: Standard Connection Details - Canam Bâtiments...CANAM Standard Connection Details REVISED AUGUST 2017](https://reader030.vdocuments.us/reader030/viewer/2022040121/5ec0a3f01aa58a26e72d491b/html5/thumbnails/77.jpg)
TCX 1 112" 38 mmSEE PLA 314" 0 BOLTS @ 6" (152 mm) CIC
:-----1�������===
�==
7=11=2.=.========
� L ____ 7 (190 mm) ___ ___,
c:::;;::::::�L�I �9�-�
COLUMN-SEE PLAN
ill mI
(76 mm) ""
2½" (64 mm)
314" 0 BOLTS @ 3" (76 mm) CIC
GIRDER TYPE BOLTS NOT SUPPLIED BY CANAM
* THIS SECTION APPLIES TO
ALL HSS AND WF 811
OR LESS
![Page 78: Standard Connection Details - Canam Bâtiments...CANAM Standard Connection Details REVISED AUGUST 2017](https://reader030.vdocuments.us/reader030/viewer/2022040121/5ec0a3f01aa58a26e72d491b/html5/thumbnails/78.jpg)
COLUMN-SEE PLAN
½" (64 mm) 3/4" 0 BOLTS @ 6" (152 mm) CIC
6"
7 1/2" (190 mm)
1" (25 mm) TYP.
) PL½"X6"
(NOT SUPPLIED BY CANAM)
DO NOT WELD BOTTOM CHORD
TO STABILIZER PLATE
GIRDER TYPE 5 BOLTS NOT SUPPLIED BY CANAM
** TO CALCULATE PLATE DIM. REFER ...._____, TO CHORD SIZE IN GIRDER DESIGN
![Page 79: Standard Connection Details - Canam Bâtiments...CANAM Standard Connection Details REVISED AUGUST 2017](https://reader030.vdocuments.us/reader030/viewer/2022040121/5ec0a3f01aa58a26e72d491b/html5/thumbnails/79.jpg)
COLUMN-SEE PLAN
½" (64 mm) 314" 0 BOLTS @ 6" (152 mm) CIC
6"
7 112" (190 mm)
1------' (152 mm)
2½" (64 mm)
314" 0 BOLTS @ 3" (76 mm) CIC
GIRDER TYPE BOLTS NOT SUPPLIED BY CANAM
![Page 80: Standard Connection Details - Canam Bâtiments...CANAM Standard Connection Details REVISED AUGUST 2017](https://reader030.vdocuments.us/reader030/viewer/2022040121/5ec0a3f01aa58a26e72d491b/html5/thumbnails/80.jpg)
COLUMN--SEE PLAN
½" (64 mm) 3/4" 0 BOLTS@ 6" (152 mm) CIC
6"
7 1/2" (190 mm)
I-----'
(152 mm)
1" (25 mm)
DO NOT WELD BOTTOM CHORD
TO STABILIZER PLATE
GIRDER TYPE BOLTS NOT SUPPLIED BY CANAM
* THIS SECTION ONLY APPLIES
TO WF 1 O" OR OVER
** TO CALCULATE PLATE DIM. REFER TO CHORD SIZE IN GIRDER DESIGN
![Page 81: Standard Connection Details - Canam Bâtiments...CANAM Standard Connection Details REVISED AUGUST 2017](https://reader030.vdocuments.us/reader030/viewer/2022040121/5ec0a3f01aa58a26e72d491b/html5/thumbnails/81.jpg)
COLUMN--SEE PLAN
½" (64 mm) 314" 0 BOLTS @ 6" (152 mm) CIC
6"
7 112" (190 mm)
I (152 mm)
1------------'
""-
1 I2½" (64 mm)
Ii 1 I
Ii 314" 0 BOLTS @ 3" (76 mm) CIC
1 I
GIRDER TYPE BOLTS NOT SUPPLIED BY CANAM
* THIS SECTION ONLY APPLIES
TO WF 1 O" OR OVER
![Page 82: Standard Connection Details - Canam Bâtiments...CANAM Standard Connection Details REVISED AUGUST 2017](https://reader030.vdocuments.us/reader030/viewer/2022040121/5ec0a3f01aa58a26e72d491b/html5/thumbnails/82.jpg)
TCX SEE PLAN
EOS TYP. r
<TYP.
-��2-,,---< EACH or ,l 6 V 51 EACHSEE PLAN SIDE SIDE
7 1/2" (190 mm)
BEARING PLATE --t'/
NOT SUPPLIEDBY CANAM
1" (25 mm)TYP. )
PL¼" X6" (NOT SUPPLIED BY CANAM)
DO NOT WELD BOTTOM CHORD
TO STABILIZER PLATE
GIRDER TYPE
** TO CALCULATE PLATE DIM. REFER TO CHORD SIZE IN GIRDER DESIGN
![Page 83: Standard Connection Details - Canam Bâtiments...CANAM Standard Connection Details REVISED AUGUST 2017](https://reader030.vdocuments.us/reader030/viewer/2022040121/5ec0a3f01aa58a26e72d491b/html5/thumbnails/83.jpg)
EOS SEE PLAN
BEARING PLATENOT SUPPLIED
BY CANAM
TYP. r <
TYP. -��2-,,----< EACH or ,.l 6 V 51 EACH
SIDE SIDE
7 1/2" (190 mm)
1" (25 mm)TYP. )
PL¼"X6" (NOT SUPPLIED BY CANAM)
DO NOT WELD BOTTOM CHORD
TO STABILIZER PLATE
GIRDER TYPE
** TO CALCULATE PLATE DIM. REFER TO CHORD SIZE IN GIRDER DESIGN
![Page 84: Standard Connection Details - Canam Bâtiments...CANAM Standard Connection Details REVISED AUGUST 2017](https://reader030.vdocuments.us/reader030/viewer/2022040121/5ec0a3f01aa58a26e72d491b/html5/thumbnails/84.jpg)
TYPICAL LOOSE TIE
ANGLE SUPPLIED BY CANAM
SECT.X
LOOSE TIE
SHOWN THUS:
LBCX