some test result about current sensor limei zhao 07/23/2003
TRANSCRIPT
![Page 1: Some Test Result about Current Sensor Limei Zhao 07/23/2003](https://reader035.vdocuments.us/reader035/viewer/2022070406/56649de45503460f94adba0f/html5/thumbnails/1.jpg)
Some Test Result about Current Sensor
Limei Zhao
07/23/2003
![Page 2: Some Test Result about Current Sensor Limei Zhao 07/23/2003](https://reader035.vdocuments.us/reader035/viewer/2022070406/56649de45503460f94adba0f/html5/thumbnails/2.jpg)
Current Sensor (1)
* No filter added* Output signal has too much noise* High pressure to current sensor
* If add filter, spend too much space
![Page 3: Some Test Result about Current Sensor Limei Zhao 07/23/2003](https://reader035.vdocuments.us/reader035/viewer/2022070406/56649de45503460f94adba0f/html5/thumbnails/3.jpg)
Current Sensor-- Test Result (1)
* Green signal is motor phase current* Red signal is output signal from current sensor
![Page 4: Some Test Result about Current Sensor Limei Zhao 07/23/2003](https://reader035.vdocuments.us/reader035/viewer/2022070406/56649de45503460f94adba0f/html5/thumbnails/4.jpg)
Current Sensor (2)
3 current sensors are needed and only two channel go to DSPbecause they cause signals transform delay
![Page 5: Some Test Result about Current Sensor Limei Zhao 07/23/2003](https://reader035.vdocuments.us/reader035/viewer/2022070406/56649de45503460f94adba0f/html5/thumbnails/5.jpg)
Current Sensor (3)
Open loop current sensor cheaper Lighter Higher ability to
withstand sustained overload
Close loop current sensor Fast response Excellent linearity Less susceptible to
electrical noise low temperature drift Preferred in high frequency
circuits Quick response and noise
immunity to high di/dt
![Page 6: Some Test Result about Current Sensor Limei Zhao 07/23/2003](https://reader035.vdocuments.us/reader035/viewer/2022070406/56649de45503460f94adba0f/html5/thumbnails/6.jpg)
Current Sensor (4)
LEM LTS 15-NP IPN Primary nominal r.m.s. current 15 At IP Primary current, measuring range 0 .. ± 45 At
V_out=2.5 ± 0.625*I_in/IPN
![Page 7: Some Test Result about Current Sensor Limei Zhao 07/23/2003](https://reader035.vdocuments.us/reader035/viewer/2022070406/56649de45503460f94adba0f/html5/thumbnails/7.jpg)
Current Sensor (5)
* Some methods to improve resolution:
![Page 8: Some Test Result about Current Sensor Limei Zhao 07/23/2003](https://reader035.vdocuments.us/reader035/viewer/2022070406/56649de45503460f94adba0f/html5/thumbnails/8.jpg)
Current Sensor (6)
For new motor LEM LA100-P Supply voltage : +12-15V IPN Primary nominal r.m.s. current: 100 At IP Primary current, measuring range: 0 .. ± 150 At Price: $30.80
![Page 9: Some Test Result about Current Sensor Limei Zhao 07/23/2003](https://reader035.vdocuments.us/reader035/viewer/2022070406/56649de45503460f94adba0f/html5/thumbnails/9.jpg)
Current Sensor-- Test Result (2)
* Using same power supply with power board* A lot of noise exists – from power ground* The red signal is output from current sensor – phase A and extend
waveform* The green signal is motor current – phase A
![Page 10: Some Test Result about Current Sensor Limei Zhao 07/23/2003](https://reader035.vdocuments.us/reader035/viewer/2022070406/56649de45503460f94adba0f/html5/thumbnails/10.jpg)
Current Sensor-- Test Result (4)
* Using separate DC power supply * The red signal is output from current sensor – phase A* The green signal is motor current – phase C
![Page 11: Some Test Result about Current Sensor Limei Zhao 07/23/2003](https://reader035.vdocuments.us/reader035/viewer/2022070406/56649de45503460f94adba0f/html5/thumbnails/11.jpg)
Current Sensor-- Test Result (5)
The isolated power supply can enhance current sensor performance by preventing digital switching noise of the logic circuitry that can be present on VSS and VCC from coupling into the current sensor analog stage.
![Page 12: Some Test Result about Current Sensor Limei Zhao 07/23/2003](https://reader035.vdocuments.us/reader035/viewer/2022070406/56649de45503460f94adba0f/html5/thumbnails/12.jpg)
DSP ADC Interface
For DSP ADC : Input signal voltage < VREFHI = 3.3 V and > VREFLO = 0 V Absolute resolution = 3.22 mV at VREFHI = 3.3 V and VREFLO
= 0 V As VREFHI decreases, VREFLO increases, or both, the absolute
accuracy increase Current sensor corresponding resolution:
3.22*10^-3=0.625*Ip/15 Ip=0.07728A=77.28mA--- when motor peak phase current is 13.9A, phase current will have a 77.28mA difference at every 1 -- smaller will better
![Page 13: Some Test Result about Current Sensor Limei Zhao 07/23/2003](https://reader035.vdocuments.us/reader035/viewer/2022070406/56649de45503460f94adba0f/html5/thumbnails/13.jpg)
* Motor phase current simulation result
![Page 14: Some Test Result about Current Sensor Limei Zhao 07/23/2003](https://reader035.vdocuments.us/reader035/viewer/2022070406/56649de45503460f94adba0f/html5/thumbnails/14.jpg)
Conclusion
Another DC power supply is needed
Will try to decrease VREFHI and increase VREFLO to increase accuracy