solartechnik-cpc-sunnyline en tedoc 04-02-2016 layout 1 · morning 365 days afternoon your boiler...
TRANSCRIPT
![Page 1: Solartechnik-CPC-Sunnyline EN tedoc 04-02-2016 Layout 1 · MORNING 365 DAYS AFTERNOON Your boiler will have a longer break due to the efficient use of the sun! The angle factor is](https://reader034.vdocuments.us/reader034/viewer/2022050222/5f67f4ebf0b32b31ef0d304e/html5/thumbnails/1.jpg)
Solar Technology
CPC and Sunnyline
collectors
Hot water treatment l Solar heatingSwimming pool heating l Process heat
3 Powerful
products
3 Modern
design
3 Lowemissions
Solar collectors
System technology
Fresh water technology
Solartechnik-CPC-Sunnyline_EN_ tedoc_04-02-2016_Layout 1 04.02.2016 14:33 Seite 1
![Page 2: Solartechnik-CPC-Sunnyline EN tedoc 04-02-2016 Layout 1 · MORNING 365 DAYS AFTERNOON Your boiler will have a longer break due to the efficient use of the sun! The angle factor is](https://reader034.vdocuments.us/reader034/viewer/2022050222/5f67f4ebf0b32b31ef0d304e/html5/thumbnails/2.jpg)
71°C
67 °C
77°C
0 %
0 l/h63°C
Oil heating
Wood heating
Heat pump
Weatherman-
function
Intelligent control
Gas heating
Everything under control with the ecomanager-touch control center
Solar module 1
Solar circuit switched off
2
Solartechnik-CPC-Sunnyline_EN_ tedoc_04-02-2016_Layout 1 04.02.2016 14:33 Seite 2
![Page 3: Solartechnik-CPC-Sunnyline EN tedoc 04-02-2016 Layout 1 · MORNING 365 DAYS AFTERNOON Your boiler will have a longer break due to the efficient use of the sun! The angle factor is](https://reader034.vdocuments.us/reader034/viewer/2022050222/5f67f4ebf0b32b31ef0d304e/html5/thumbnails/3.jpg)
ecomanager-touch
thinks along with you by measuring
and controlling!
The change in outside temperatures are considered
to ensure your own personal comfort indoors. If the boi-
ler is combined with a solar system, the burner will only
start if the thermal energy supplied by the solar system
is insufficient. Unnecessary burning is avoided.
The ecomanager-touch is very simple to use.
It provides individual adjustment options and a perfectly
tuned heating system.
The intelligent control
ecomanager-touch
When it comes to your everyday comfort, the controller
is very important. You determine when, where and
how hot.
l 7” VGA colour touch display guarantees simple,
logical operation. Powerful microprocessor with
power-sawing standby mode
l 1 standard heating circuit
− 3-point heating circuit curve
− with 3 moduls expandable up to 8 (optional).
l 1 domestic hot water charging circuit,
expandable up to 4.
l Fresh water module with or without circulation
pump adjustable via expansion module (optional).
l Up to 2 x 3 or 4 x 2 adjustable solar circuits
(optional) - also suitable for high efficiency pumps.
l Possibility for visualisation on smartphones, tablets
and PCs! Info messages via e-mail by Ethernet
interface or via SMS on your mobile phone.
l Weatherman-function: indicates good weather, the
boiler essentially goes back to sleep, even if tempe-
ratures are still cool in the mornings. This is because,
if sunshine is expected, the system knows solar
energy will heat the buffer cylinder shortly afterwards.
Solar plant
mySOLARFOCUS app
09:11:31
°C
°C
M
°C
°C
0 %
24618
12
Heating circuit 1
31 Flow temperature
37
Mixer position
No request on buffer
Heating circuit in heating mode
Heating circuit 13:37:37
5
Boiler 64
44 °C
44 °C
320 l/h
32 °C
25°C27°C32°C
0 %
max.
50 °C
min.
22 °C
45 °C 29 °C
-15 °C 0 °C +15 °C
23 °C
3-Punkt
10 °C
Act. Priority
Tank 1
Solar module 1
Cal. flow temperature 22 °C
Solar circuit switched off
Flow temperature °C
Reduction
3
makes you independent
Solartechnik-CPC-Sunnyline_EN_ tedoc_04-02-2016_Layout 1 04.02.2016 14:33 Seite 3
![Page 4: Solartechnik-CPC-Sunnyline EN tedoc 04-02-2016 Layout 1 · MORNING 365 DAYS AFTERNOON Your boiler will have a longer break due to the efficient use of the sun! The angle factor is](https://reader034.vdocuments.us/reader034/viewer/2022050222/5f67f4ebf0b32b31ef0d304e/html5/thumbnails/4.jpg)
In just 3 hours, the sun supplies enough energy to cover
the annual energy needs of the entire population of the
earth.
The potential of solar energy is thus greater than the
sum of all other renewable energy sources together.
Both diffuse and direct sunlight (solar radiation) can be
used for energy generation.
The average annual global radiation in Central Europe
totals approx. 950 to 1.500 kWh/m²
W
E
120 105 75 60 45 30 15 15 30 45 60 75 105 120
90 EAST 0 SOUTH 90 WEST
10 h
9 h
8 h
7 h
5 h
13 h
14 h
15 h
16 h
17 h
18 h
19 h
June 21
May 21
April 21
March 21
February 21
January 21
July 21
August 21
September 21
October 21
November 21
Noon
December 21
Noon
70°
60°
50°
40°
30°
20°
10°
6 h
June 21
S
Morning
11 h
December 21
Morning
Evening
Diagrammatic view
Sun table− 47 degree of latitude
Summer solstice
Winter
solstice
It would be ideal if the collector always faced southThe irradiation angle of the sun on the collector surface changes continually with the earth's movement. This means
that the majority of the sun's rays strike the collector at an angle. The positioning of the collectors therefore plays
an important role when designing the solar energy system.
Ground reflection
Direct sunlight
Diffuse sunlight
Scatter in the
denser atmosphere
Absorption in
the atmosphereReflection
by clouds Diffuse sunlight
+ Direct sunlight
Available solar energy
Solar constant
1367 W/m2
The sun never sends us a bill
4
Solartechnik-CPC-Sunnyline_EN_ tedoc_04-02-2016_Layout 1 04.02.2016 14:33 Seite 4
![Page 5: Solartechnik-CPC-Sunnyline EN tedoc 04-02-2016 Layout 1 · MORNING 365 DAYS AFTERNOON Your boiler will have a longer break due to the efficient use of the sun! The angle factor is](https://reader034.vdocuments.us/reader034/viewer/2022050222/5f67f4ebf0b32b31ef0d304e/html5/thumbnails/5.jpg)
Gre
ate
r energ
y losses
The s
un's
rays
cannot penetr
ate
.
Always south would be ideal
90 80 70 60 50 40 30 20 10 0 10 20 30 40 50 60 70 80 9090
80
70
60
50
40
30
2010
010
20
30
40
50
60
70
80
90WEST
SOUTH
EAST
70%
80%
90%
95%
100%
Azimuth
(degrees)
Azimuth
(degrees)
Roof inclination (degrees)
Only
5%
of energ
y
is lost.
(therm
al em
issio
n)
The s
un's
rays a
re
absorb
ed a
t 95%
.
Standard flat plate
collector:Dirt deposits reduce
the collector yield
SOLARFOCUS CPC collector:Sealed construction guarantees
consistently high energy
yields for decades
5
makes you independent
Solar irradiation during the course of the dayThe theoretically optimum orientation would be exactly
to the south in order to be able to use the solar irradiation
throughout the day. As the conditions in the early morning
hours are less favourable to the use of solar energy
(morning mists, cooler air temperatures), a
deviation of approx. 10° to the south-west is recommended.
As a result, the poorer conditions in the
morning are deliberately not used, but the late afternoon
sun can be utilised longer and under better conditions.
A heart of copperThe heart of any collector is the absorber which converts the incident
sun rays into heat. SOLARFOCUS uses only copper absorbers which are
coated with a highly selective layer. Thanks to the crystalline surface of the coating,
around 95% of the sun rays are absorbed.
Airtight and watertight design of SOLARFOCUS CPC collectorsIn contrast with conventional flat plate collectors, the CPC collector has an airtight and watertight construction.
When heated, the air inside expands and the pressure is relieved via a special pressure relief valve.
When the collector cools down again, a partial vacuum is created and the solar safety glass is supported over a large
area by the reflectors.
The airtight and watertight design without ventilation holes and rivets prevents any soiling of the absorbers, provides
permanent protection for the inside of the collector and guarantees constant energy yields for years to come.
Cu
Solartechnik-CPC-Sunnyline_EN_ tedoc_04-02-2016_Layout 1 04.02.2016 14:33 Seite 5
![Page 6: Solartechnik-CPC-Sunnyline EN tedoc 04-02-2016 Layout 1 · MORNING 365 DAYS AFTERNOON Your boiler will have a longer break due to the efficient use of the sun! The angle factor is](https://reader034.vdocuments.us/reader034/viewer/2022050222/5f67f4ebf0b32b31ef0d304e/html5/thumbnails/6.jpg)
6
CPC-collector – the advantages
The collector is exposed to environmental influences such as wind, rain, dirt, UV radiation, snow loads and
extreme variations in temperature over a period of decades. It is therefore all the more important that only
high-quality materials are used that can withstand these adverse conditions. Materials such as wood, plastic
and rubber do not offer the necessary resistance in the long term.
Collector tray (1)l The 1.5 mm tight welded aluminium tray without ventilation holes forms the “foundation”.
l The airtight and watertight design without ventilation holes and rivets protects the inside of
your collector for decades.
Absorber (2)l The highly selective coated copper absorber impresses with a solar absorption rate of
approx. 95% and a thermal emission rate of approx. 5%.
l The floating absorber coated on both sides guarantees maximum energy yields.
Reflector (3)l The cylindrical, high-gloss rolled, galvanically anodized pure aluminium reflector
concentrates the penetrating solar radiation onto the vertically installed absorber ship.
l The cylindrical, mirror-finish rolled, galvanically anodised pure aluminium reflector
bundles the incidental sun rays onto the vertically installed absorber strip.
The reflectors in the tray are protected against environmental
influences, thereby guaranteeing a long service life.
No wear of the coating. Optimum light bundling by the
cylindrical form of the CPC reflector. As a result, the
diffuse fraction of the light is also absorbed (Kdiff = 0.87).
Solar safety glass (4)l 4 mm low iron content prism structured solar safety glass
l Very high light permeability for high yields, impact and
hail-resistant
Special seal (5)l Permanently elastic UV-protected special seal
l Connects the tray, the glass and the glass holding strip.
Diffusion-proof. Prevents the ingress of moisture and dirt.
Glass holding strip (6)l Anodised aluminium special profile.
l A UV and weathering-resistant aluminium profile instead of a rubber seal ensures the
protection of the glass edges. Guarantees the lasting connection of glass and tray.
Flush-sealing connections (7)l 1/2” external thread with flat seal
l The surface seals on the inside and outside of the tray are fastened plane-parallel with brass nuts and
hermetically seal the tray against environmental influences. No rubber or plastic seals susceptible to
weathering. Simple hydraulic connection of the collectors.
lT
EC
HN
OLO
GY
l
BE
NE
FIT
1
8
Solartechnik-CPC-Sunnyline_EN_ tedoc_04-02-2016_Layout 1 04.02.2016 14:33 Seite 6
![Page 7: Solartechnik-CPC-Sunnyline EN tedoc 04-02-2016 Layout 1 · MORNING 365 DAYS AFTERNOON Your boiler will have a longer break due to the efficient use of the sun! The angle factor is](https://reader034.vdocuments.us/reader034/viewer/2022050222/5f67f4ebf0b32b31ef0d304e/html5/thumbnails/7.jpg)
7
SCHEMATISCHE DARSTELLUNG
Schematic view: C
PC-collecto
r
Negative pressure relief valve (8)l When the air inside the collector is warmed for the first time, the air expands and a positive pressure is created.
The valve opens and the air can escape. When the air cools again, the valve closes and a negative pressure is
created inside the collector. The reflectors support the glass pane on the tray.
l No corrosion inside the collector caused by aggressive ambient air.
No exchange between inside and outside air, and hence no convectional heat losses.
No condensation, and therefore no destruction of the highly absorber coating.
Annular gap air vent (9)l The annular gap air vent is located in the distributor pipe of the collector.
l The annular gap air vent allows the solar collectors connected in series to be easily vented!
No ventilation bores
No plastic
No wood
No insulation
No rubber seals
3
6
2
7
4
5
9
PREMIUM
yearsyears
up toup to
conde
nsatio
n according
acco
rding to
guarantee
pass
Guarantee
Guarantee
Guarantee
Guarantee
3
3
3
3
3
The premium class
Exclusively made of high quality and heat-resistant materials!
makes you independent
Solartechnik-CPC-Sunnyline_EN_ tedoc_04-02-2016_Layout 1 04.02.2016 14:33 Seite 7
![Page 8: Solartechnik-CPC-Sunnyline EN tedoc 04-02-2016 Layout 1 · MORNING 365 DAYS AFTERNOON Your boiler will have a longer break due to the efficient use of the sun! The angle factor is](https://reader034.vdocuments.us/reader034/viewer/2022050222/5f67f4ebf0b32b31ef0d304e/html5/thumbnails/8.jpg)
8
The reflector principle
100%
50% 50%
Each ingenious invention is based on a
simple principeThe angle of the sun on the collector surface
changes continually with the Earth’s movement.
A standard flat-plate collector reaches its optimum ef-
ficiency when the sunlight hits the absorber directly at
an angle of 90°. However, this means that the majo-
rity of the sun's rays will strike the collector at an
angle.
SUNSET SUNRISE
SUNSET SUNRISE
MORNING 365 DAYS AFTERNOON
Your boiler will have a longer break due to the efficient use of the sun!The angle factor is the ratio of the optical efficiency from the current angle of entry to the vertical entry.
The cylindrical shape of the CPC reflector allows it to absorb even diffuse light. Angle factor at 30 ° angle deviation
= 1.10.
Concentration in flat, weak radiationDue to its CPC geometry, the collector can still achieve usable temperatures even with weak sunlight at a low angle of
incidence.
0 10 20 30 40 50 60 70 80
EAST SOUTH WEST
Declination
Incid
ence A
ngle
Modifie
r (-
)
80 70 60 50 40 30 20 10
SOLARFOCUS layout
FLAT-PLATE COLLECTOR layout
Better energy absorption
1,10 1,02
1,0
l The vertical installation of the absorber allows the
use of the inclined penetrating light.
l The small absorber strip designates a small heat
radiating surface and therefore less heat loss
(radiator principle).
l At the same time the small absorber strips
of the CPC collector ensure rapid heating
due to increased concentration.
l Based on the cylindrical design of the CPC reflector,
the diffused part of the light is also absorbed
(Kdiff= 0.87).
l This is important during the transitional period
(spring and autumn), since up to 80 % of the sun’s
rays penetrate at an angle.
l Normal flat-plate collectors are irradiated from a
single side and must be insulated on the back of the
absorber to minimise heat loss.
The CPC collector absorber is irradiated from both
sides. Due to this double-sided irradiation, there is
effectively no blind side to the absorber which would
otherwise represent a net heat loss area.
l The small absorber strip of the CPC collector also
provides quick heating.
Solartechnik-CPC-Sunnyline_EN_ tedoc_04-02-2016_Layout 1 04.02.2016 14:33 Seite 8
![Page 9: Solartechnik-CPC-Sunnyline EN tedoc 04-02-2016 Layout 1 · MORNING 365 DAYS AFTERNOON Your boiler will have a longer break due to the efficient use of the sun! The angle factor is](https://reader034.vdocuments.us/reader034/viewer/2022050222/5f67f4ebf0b32b31ef0d304e/html5/thumbnails/9.jpg)
9
CPC-collector – the benefits at a glance
Subject to technical changes
TESTED ACCORDING TO EN 12975-1 and -2
10-year guarantee against condensation
No insulation in the collector
Only high-quality materials
Perfect exploitation of light at a low incident angle
87% diffusion factor
Simple hydraulic connection
Suitable for all installation variants
Flat construction
Universal application: Swimming pool heating,
DHW preparation, heating support
S1 S1K
Structure CPC-collector CPC-collector
L = length [cm] 240 212.5
W = width [cm] 115.5 115.5
H = height [cm] 6.5 6.5
Surface area [m2] 2.8 2.5
Aperture area [m2] 2.5 2.3
Content [l] 1.6 1.4
Weight (empty) [kg] 55 50
Heat loss factor [W/(m²K)], [W/(m²K²)] A1 = 3.3 / A2 = 0.012
Conversion factor (according to aperture area) 0.74
Incidence angle modifier 30° / 50° 1.1 / 1.02
Diffusion factor [Kdiff] 0.87
Heat capacity [J/m2K] 3950
Flow rate [l/m2h] 20 - 70
Pressure lost at 20°C and 50 l/m2h [mbar/m2] 4.1
Glass cover Solar safety class
Max. operating pressure [bar] 10
Technical data
3
3
3
3
3
makes you independent
Solartechnik-CPC-Sunnyline_EN_ tedoc_04-02-2016_Layout 1 04.02.2016 14:33 Seite 9
![Page 10: Solartechnik-CPC-Sunnyline EN tedoc 04-02-2016 Layout 1 · MORNING 365 DAYS AFTERNOON Your boiler will have a longer break due to the efficient use of the sun! The angle factor is](https://reader034.vdocuments.us/reader034/viewer/2022050222/5f67f4ebf0b32b31ef0d304e/html5/thumbnails/10.jpg)
10
Sunnyline – the flat plate collector
The collector is exposed to environmental influences such as wind, rain, dirt, UV radiation, snow loads and
extreme variations in temperature over a period of decades. It is therefore all the more important that only
high-quality materials are used that can withstand these adverse conditions. Materials such as wood, plastic
and rubber do not offer the necessary resistance in the long term.
Collector tray (1)l The 1.5 mm tight welded aluminium tray forms the “foundation ”.
l The high-quality finishing protects the inside of your collector for decades to come.
Absorber (2)l The highly selective coated full-area copper absorber impresses with a solar absorption rate
of approx. 95% and a thermal emission rate of approx. 5%.
l The floating absorber unit (blue-line absorber plate and copper heat transfer medium
pipework are welded ultrasonically) guarantees the highest energy yields.
Perfect appearance.
Solar safety glass (3)l 4 mm low iron content prism structured solar safety glass.
l Very high light permeability for high yields, impact and hail-resistant.
Special seal (4)l Permanently elastic UV-protected special seal.
l Connects the tray, the glass and the glass holding strip.
Diffusion-proof. Prevents the ingress of moisture and dirt.
Glass holding strip (5)l Anodised aluminium special profile.
l A UV and weather-resistant aluminium profile
instead of a rubber seal ensures reliable protection
of the glass edges. Guarantees the lasting connection
of glass and tray.
Flush-sealing connections (6)l 1/2” external thread with flat seal.
l The surface seals on the inside and outside of the tray are
fastened plane-parallel with brass nuts and hermetically seal the tray
against environmental influences. No rubber or plastic seals susceptible to
weathering. Simple hydraulic connection of the collectors.
Backing insulation (7)l 50 mm low-binder mineral wool.
l Thanks to the low binder content in the mineral wool, the insulation releases practically no gases on
exposure to heat.
Annular gap air vent (8)l The annular gap air vent is located in the distributor pipe of the collector.
l The annular gap air vent allows the solar collectors connected in series to be easily vented!
1
lT
EC
HN
OLO
GY
l
BE
NE
FIT
Solartechnik-CPC-Sunnyline_EN_ tedoc_04-02-2016_Layout 1 04.02.2016 14:33 Seite 10
![Page 11: Solartechnik-CPC-Sunnyline EN tedoc 04-02-2016 Layout 1 · MORNING 365 DAYS AFTERNOON Your boiler will have a longer break due to the efficient use of the sun! The angle factor is](https://reader034.vdocuments.us/reader034/viewer/2022050222/5f67f4ebf0b32b31ef0d304e/html5/thumbnails/11.jpg)
11
3
2
7
4
5
8
up toup to
yearsyearsac
cord
ing to guara
ntee pas
s
Guarantee
Guarantee
Guarantee
Guarantee
Schematic view S
unnylin
e flat p
late collecto
r
Full-area copper absorber
No plastic
No wood
No rubber seals
3
3
3
3
Exclusively made of high quality and heat-resistant materials!
makes you independent
Solartechnik-CPC-Sunnyline_EN_ tedoc_04-02-2016_Layout 1 04.02.2016 14:34 Seite 11
![Page 12: Solartechnik-CPC-Sunnyline EN tedoc 04-02-2016 Layout 1 · MORNING 365 DAYS AFTERNOON Your boiler will have a longer break due to the efficient use of the sun! The angle factor is](https://reader034.vdocuments.us/reader034/viewer/2022050222/5f67f4ebf0b32b31ef0d304e/html5/thumbnails/12.jpg)
12
Sunnyline flat plate collector – the benefits at a glance
TESTED ACCORDING TO EN 12975-1 and -2
Sunny 28 Sunny 21
Structure Flat plate collector Flat plate collector
L = Length [cm] 240 178.5
W = Width [cm] 115.5 115.5
H = Height [cm] 8.5 8.5
Surface area [m2] 2.77 2.1
Aperture area [m2] 2.5 1.82
Content [l] 1.3 1.08
Weight (empty) [kg] 50 40
Heat loss factor [W/(m²K)], [W/(m²K²)] A1 = 3.4 / A2 = 0.011
Conversion factor (aperture area) 0.78
Flow rate based on [l/m2h] 20 - 70
Pressure lost at 20°C and 50 l/m2h [mbar/m2] 4.1
Glass cover Solar safety glass
Max. operating pressure [bar] 10
Subject to technical changes
10-year warranty
Strictly high-quality materials
Welded aluminium tray: Provides the best possible
protection for the inside of the collector for decades
to come. Highly selective full-area copper absorber
50 mm insulation for high efficiency, 4 mm low iron
content solar glass, solar transmission 92%
Suitable for all installation variants
(roof-integrated, on-roof, free-standing,
wall mounted, etc.)
Universal application: Swimming pool heating,
DHW preparation, heating support
Low installation costs
Simple hydraulic connection
Technical data
3
3
3
3
3
3
Solartechnik-CPC-Sunnyline_EN_ tedoc_04-02-2016_Layout 1 04.02.2016 14:34 Seite 12
![Page 13: Solartechnik-CPC-Sunnyline EN tedoc 04-02-2016 Layout 1 · MORNING 365 DAYS AFTERNOON Your boiler will have a longer break due to the efficient use of the sun! The angle factor is](https://reader034.vdocuments.us/reader034/viewer/2022050222/5f67f4ebf0b32b31ef0d304e/html5/thumbnails/13.jpg)
FWM
konvent
Zonne-energiecircuit in werking
09:11:31Zonneregelaar
93 °C
65 °C
60 °C100 %
307 l/h40 °C
pelletelegance
FWM
ko
nve
nt
3-5
4-6
2-4
150 m²
120 m²
90 m²
13
Planning/design of a solar system
FRESH WATER SYSTEM
ca. 5.0 m² 300 liters
DHW tank
ca. 5.6 m² 300 - 400 litres
DHW tank
ca. 8.4 m² 300 - 500 litres
DHW tank
ca. 14.0 m² 800 litres
Hyko Thermal
Store
ca. 16.8 m² 1000 litres
Hyko Thermal
Store
ca. 22.4 m² 1500litres buffer
store and 400
litres DHW tank
Persons and
Intended Use Collector Area Storage Tank
octoplus, fresh water module and solar system
pellettop, with HYKO storage tank and solar plant
pelletelegance with stratified buffer storage
tank, drinking water storage tank and solar
plant
These design recommendations should assist you in
planning your system. The assumed values are for
guidance only. Important parameters, such as hot water
consumption, roof incline and aspect must be given
individual consideration during the planning phase.
The house energy index and type of heating are decisive
in determining the coverage for partial solar heating
installations.
.
therminator II touch with buffer tank, stratified load module,
fresh water module and solar plant
SOLARFOCUS, thanks to hundreds of standard schematics,
can aid in your system, from conception and design to inception.
makes you independent
Solartechnik-CPC-Sunnyline_EN_ tedoc_04-02-2016_Layout 1 04.02.2016 14:34 Seite 13
![Page 14: Solartechnik-CPC-Sunnyline EN tedoc 04-02-2016 Layout 1 · MORNING 365 DAYS AFTERNOON Your boiler will have a longer break due to the efficient use of the sun! The angle factor is](https://reader034.vdocuments.us/reader034/viewer/2022050222/5f67f4ebf0b32b31ef0d304e/html5/thumbnails/14.jpg)
1414
Capacity Diameter Diameter Total Upper heating Lower heating Weight Tilted El. screw-in heating
without insulation with insulation height coil coil height 6/4“ possible
300 l 500 mm 600 mm 1794 mm 0.8 m2 1.52 m2 148 kg 1892 mm 3
400 l 600 mm 700 mm 1591 mm 1.0 m2 1.81 m2 159 kg 1738 mm 3
500 l 600 mm 700 mm 1921 mm 1.27 m2 1.95 m2 230 kg 2044 mm 3
System technology
YOUR benefitsl Simple assembly
l Read-to-use DHW tank
l Avoid assembly errors with the
pre-assembled solar control unit and pump set.
Sensoren
Sensor 3
Sensor 1
Sensor 2
S1S2S3
up toup to
yearsyears
acco
rding to
guarantee
pass
Guarantee
Guarantee
Guarantee
Guarantee
3 DHW tank with pre-fitted pump set and
solar control unit
3 Dual coil solar storage tank
3 Also available with high efficiency pump
Plug-IN Domestic Hot Water Tank with solar plant for hot water treatment
Solartechnik-CPC-Sunnyline_EN_ tedoc_04-02-2016_Layout 1 04.02.2016 14:34 Seite 14
![Page 15: Solartechnik-CPC-Sunnyline EN tedoc 04-02-2016 Layout 1 · MORNING 365 DAYS AFTERNOON Your boiler will have a longer break due to the efficient use of the sun! The angle factor is](https://reader034.vdocuments.us/reader034/viewer/2022050222/5f67f4ebf0b32b31ef0d304e/html5/thumbnails/15.jpg)
1515
Capacity Diameter Diameter Total Upper heating Lower heating Weight Tilted El. screw-in heating
without insulation with insulation height coil coil height 6/4“ possible
600 l /R 700 mm 900 mm 1700 mm 1.2 m2 1.8 m2 145 kg / 158 kg 1670 mm 3
800 l /R 790 mm 990 mm 1760 mm 1.8 m2 2.4 m2 170 kg / 192 kg 1740 mm 3
1000 l /R 790 mm 990 mm 2090 mm 2.4 m2 3 m2 202 kg / 232 kg 2100 mm 3
1250 l /R 950 mm 1200 mm 2100 mm 2.4 m2 3 m2 234 kg / 273 kg 2100 mm 3
1500 l /R 1000 mm 1250 mm 2125 mm 2.4 m2 3.6 m2 272 kg / 308 kg 2215 mm 3
YOUR benefits3 Combined buffer tank (optional with two coils)
for heating support and hot water preparation
3 Stratified charging pipe for the heating return flow
3 Stratified separation plate
l Low cost, low space requirement
for hot water treatment and solar
heating support
l Hygienic domestic hot water preparation with
continous flow mode
l Simple, efficient system hydraulics
l Serves as a storage tank for solar and
biomass energy
FRESH WATER SYSTEM
Hygienic combined tank „HYKO” with solar plant
for hot water treatment in continuous flow mode and heating support
Zonne-energiecircuit in werking
09:11:31Zonneregelaar
93 °C
65 °C
60 °C100 %
307 l/h40 °C
pelletelegance
Erverything from one supplier
NOTICE:
The grey-shaded area on the diagram,
the return booster module with mixer
motor for buffer/DHW tank charging is
integrated into the pelletelegance
(standard).
makes you independent
Solartechnik-CPC-Sunnyline_EN_ tedoc_04-02-2016_Layout 1 04.02.2016 14:34 Seite 15
![Page 16: Solartechnik-CPC-Sunnyline EN tedoc 04-02-2016 Layout 1 · MORNING 365 DAYS AFTERNOON Your boiler will have a longer break due to the efficient use of the sun! The angle factor is](https://reader034.vdocuments.us/reader034/viewer/2022050222/5f67f4ebf0b32b31ef0d304e/html5/thumbnails/16.jpg)
Capacity Diameter Diameter Total Upper heating Lower heating Weight Tilted El. screw-in heating
without insulation with insulation height coil coil height 6/4“ possible
500 l /R 650 mm 850 mm 1700 mm --- 1.2 m2 103 kg 1670 mm on request
800 l /R 790 mm 990 mm 1760 mm --- 1.8 m2 130 kg 1740 mm on request
1000 l /R 790 mm 990 mm 2090 mm --- 3.0 m2 156 kg 2090 mm on request
1250 l /R 950 mm 1200 mm 2060 mm --- 3.0 m2 189 kg 2090 mm on request
1500 l /R 1000 mm 1250 mm 2200 mm --- 3.6 m2 210 kg 2210 mm on request
500 l /2R 650 mm 850 mm 1700 mm 1.2 m2 1.8 m2 131 kg 1670 mm on request
800 l /2R 790 mm 990 mm 1760 mm 1.6 m2 2.4 m2 169 kg 1740 mm on request
1000 l /2R 790 mm 990 mm 2090 mm 2.4 m2 3.0 m2 204 kg 2090 mm on request
1050 l /2R 790 mm 990 mm 2200 mm 2.4 m2 3.0 m2 209 kg 2170 mm on request
1250 l /2R 950 mm 1200 mm 2060 mm 2.4 m2 3.0 m2 240 kg 2090 mm on request
1500 l /2R 1000 mm 1250 mm 2200 mm 2.4 m2 3.6 m2 254 kg 2210 mm on request
16
3 Buffer tank with 2 coils
für Schnellladung
3 Hygienic domestic hot water preparation with
external module
3 Ideal in connection with a biomass boiler
3 Stratified charging pipe for the heating return flow
3 Stratified separation plate
FWM
ko
nve
nt
Buffer tank with solar thermal system and fresh water module for external hot water in continuous
flow mode and heating support
FRESH WATER SYSTEM
YOUR benefitsl Serves as a storage tank for solar and biomass energy
l Low space requirement
l Simple, efficient system hydraulics
System technology
Solartechnik-CPC-Sunnyline_EN_ tedoc_04-02-2016_Layout 1 04.02.2016 14:34 Seite 16
![Page 17: Solartechnik-CPC-Sunnyline EN tedoc 04-02-2016 Layout 1 · MORNING 365 DAYS AFTERNOON Your boiler will have a longer break due to the efficient use of the sun! The angle factor is](https://reader034.vdocuments.us/reader034/viewer/2022050222/5f67f4ebf0b32b31ef0d304e/html5/thumbnails/17.jpg)
Capacity Diameter Diameter Total Upper heating Lower heating Weight Tilted El. screw-in heating
without insulation with insulation height coil coil height 6/4“ possible
500 l/PS/SPS 650 mm 850 mm 1700 mm --- --- 79/90 kg 1670 mm on request
800 l/PS/SPS 790 mm 990 mm 1760 mm 97/112 kg 1740 mm on request
1000 l/PS/SPS 790 mm 990 mm 2090 mm --- --- 114/132 kg 2090 mm on request
1050 l/SPS 790 mm 990 mm 2200 mm --- --- ---/126 kg 2170 mm on request
1250 l/PS/SPS 950 mm 1200 mm 2060 mm 146/162 kg 2090 mm on request
1500 l/PS/SPS 1000 mm 1240 mm 2210 mm --- --- 163/182 kg 2210 mm on request
2000 l/PS 1100 mm 1340 mm 2440 mm 225/--- kg 2450 mm on request
3000 l/PS 1250 mm 1490 mm 2720 mm --- --- 280/--- kg 2705 mm on request
4000 l/PS 1400 mm 1640 mm 2900 mm 431/--- kg 2910 mm on request
5000 l/PS 1600 mm 1840 mm 2995 mm --- --- 501/--- kg 3010 mm on request
17
3 Buffer storage tank for large-scale solar energy
systems
3 With external two-zone solar stratified charging
module
3 Hygienic domestic hot water preparation with
external module
3 Ideal in connection with a biomass boiler
3 Stratified charging pipe for the heating return flow
3 Stratified separation plate
FWM
ko
nve
nt
Optionally with fresh water module or DHW tank
Buffer tank with solar thermal system, solar stratified charging module and fresh water module
for external hot water in continuous flow mode and heating support
FRESH WATER SYSTEM
YOUR benefitsl Serves as a storage tank for solar and
biomass energy
l Energy is supplied only when required
l Avoids unnecessary boiler start-ups and low-load
operation - longer service life for the boiler and a
higher solar coverage rate for your solar energy
system
Everything from one supplier
makes you independent
Solartechnik-CPC-Sunnyline_EN_ tedoc_04-02-2016_Layout 1 04.02.2016 14:34 Seite 17
![Page 18: Solartechnik-CPC-Sunnyline EN tedoc 04-02-2016 Layout 1 · MORNING 365 DAYS AFTERNOON Your boiler will have a longer break due to the efficient use of the sun! The angle factor is](https://reader034.vdocuments.us/reader034/viewer/2022050222/5f67f4ebf0b32b31ef0d304e/html5/thumbnails/18.jpg)
18
Solar stratified charging module −
SLM 20-150 with or without fast charging mode:
with high-efficiency pump
Legend:
1 Solar circuit pump
2 Solar circuit flow
3 "Plug-and-play" wiring
4 Wall mounting
5 Solar circuit pressure gauge
6 Solar circuit safety valve
7 Flow regulator
8 Filling port
9 Solar circuit return
10 Solar circuit flow
11 3-way motorised
switching valve
12 Shut-off ball valve
13 3-circuit controller
14 Venting valve
15 Buffer tank charging
pump
16 Heat exchanger return
from buffer tank
17 Flow regulator
18 Shut-off ball valve
19 Plate-type heat exchanger
20 Flow heat exchanger to
buffer tank
21 3-way motorised valve
buffer return
(only at fast charging mode)
3 For optimum charging of the buffer storage tank
on two levels
3 From 20 m² - 150 m² collector area
1
2
3
45
6
7
8
8
9
10
1120
21
12
13
14
15
16
17
18
19
A)
Solar stratified charging module with fast charging mode
YOUR benefitsl Optimum energy utilisation through stratified
charging of the buffer storage tank
l Minimum effort required for assembly
l Delivered ready for connection
Technical data, stratified charging modules
Solar stratified charging module / Fresh water module
SLMHE 20 SLMHE 40 SLMHE 60 SLMHE 80 SLMHE 100 SLMHE 150
Collector area m2 up to 20 up to 40 up to 60 up to 80 up to 100 up to 150
Power kW up to 10 up to 20 up to 30 up to 40 up to 50 up to 65
SLMHE - primary pump Para 15/1-7 15/1-7 15/1-11.5 15/1-11.5 25/1-11 25/1-11
SLMHE - secondary pump Para 15/1-7 15/1-7 15/1-7 15/1-7 25/1-7 25/1-7
Buffer/solar connections 3/4”IT 3/4”IT 1”IT 1”IT 1”IT 1”IT
H/W/D 770/330/350 770/330/350 960/370/510 960/370/510 1130/440/630 1130/440/630
Weight kg Approx. 25 Approx. 30 Approx. 45 Approx. 55 Approx. 65 Approx. 85
B)
Solartechnik-CPC-Sunnyline_EN_ tedoc_04-02-2016_Layout 1 04.02.2016 14:35 Seite 18
![Page 19: Solartechnik-CPC-Sunnyline EN tedoc 04-02-2016 Layout 1 · MORNING 365 DAYS AFTERNOON Your boiler will have a longer break due to the efficient use of the sun! The angle factor is](https://reader034.vdocuments.us/reader034/viewer/2022050222/5f67f4ebf0b32b31ef0d304e/html5/thumbnails/19.jpg)
19
Fresh water modules
FWMeco, FWMkonvent and FWMautark
3 Fresh water modules with high-efficiency pump
3 The right solution for every requirement
3 Output capacity 20 up to 50 l/min
Extensive information of fresh water modules can be found in the brochure „Fresh water modules“
FRESH WATER SYSTEM
A freshwater module heats drinking water in accordance
with the instant hot water principle, only when it’s needed. In
contrast to a tradition hot water tank or boiler, water – which
we need to live – is not used to store energy, and stored as
hot water for hours or days at a time.
Only when hot water is needed is it heated to the desired
temperature with the aid of a stainless steel plate heat ex-
changer. Stockpiling over the course of days is now a thing
of the past.
The energy for heating drinking water is supplied by a buffer
tank, which can be heated by the different systems – by
solar power systems as well as by a pellet boiler, wood-fired
boiler, traditional oil/gas boiler, heat pumps or other sy-
stems. High-efficiency pumps ensure the right volume flow
from the buffer to the stainless steel plate heat exchanger.
Hot water –
hygienic and comfortable
When legionella
fall on fertile ground
Accumulation of legionella(L. pneumophila) magnified with the aidof the electron microscope (TEM). Onebacterium is approximately 0.003 mm long.
Image: Hans R. Gelderblom, Rolf Reissbrodt / Robert Koch Institute
makes you independent
schnelles
Absterben
langsames
Absterben
kein
Wachstum
langsames
Wachstum
optimales
Wachstum
kein
Wachstum
(Legionellen schlafen)
langsames
Wachstum
40
50
60
70
langsames
Wachstum
30
20
80Die offquickly
Die offslowly
No growth
Slowlygrowth
Optimumgrowth
Slowlygrowth
No growth
(Legionelladormant)
10°C: Koud drinkwater
35°C: Douches
55 - 60°C: Warmwaterreservoir
Solartechnik-CPC-Sunnyline_EN_ tedoc_04-02-2016_Layout 1 04.02.2016 14:35 Seite 19
![Page 20: Solartechnik-CPC-Sunnyline EN tedoc 04-02-2016 Layout 1 · MORNING 365 DAYS AFTERNOON Your boiler will have a longer break due to the efficient use of the sun! The angle factor is](https://reader034.vdocuments.us/reader034/viewer/2022050222/5f67f4ebf0b32b31ef0d304e/html5/thumbnails/20.jpg)
20
For which Kind of Applications?Areas of application for large-scale solar thermal systems: small businesses, industry, the catering and hotel industry,
and the public sector
How to start?Give us a call! Our friendly staff at the SOLARFOCUS Technical Support will be glad to assist you in planning and
technical design of your large scale solar thermal systems.
Industrial prozess heat
San Tomas College, Lisbon (P)
3 64.4 m2 CPC collectors
3 Hot water preparation
Solartechnik-CPC-Sunnyline_EN_ tedoc_04-02-2016_Layout 1 04.02.2016 14:35 Seite 20
![Page 21: Solartechnik-CPC-Sunnyline EN tedoc 04-02-2016 Layout 1 · MORNING 365 DAYS AFTERNOON Your boiler will have a longer break due to the efficient use of the sun! The angle factor is](https://reader034.vdocuments.us/reader034/viewer/2022050222/5f67f4ebf0b32b31ef0d304e/html5/thumbnails/21.jpg)
21
Pay Back?Large scale solar thermal systems today achieve pay back times of significantly under 10 years (with RHI or alike
e.g. 2-7 years). With that such investments not only help to preserve and treat with care our environment, the energy
produced essentially becomes free within a reasonably short periode.
Hotel Liebnitzmühle, Liebnitz (A)
3 222 m2 CPC collectors
3 Swimming pool heating
3 Hot water preparation
3 Heating support
Cheese dairy, Queixerías BAMA, A Coruna (E)
3 56 m2 CPC collectors
3 Cheese dairy wash
makes you independent
VERLÄN GERTE GARAN
TIE
GEP
RÜFTE QUALITÄT
2016SOLARFOCUS
Solartechnik-CPC-Sunnyline_EN_ tedoc_04-02-2016_Layout 1 04.02.2016 14:35 Seite 21
![Page 22: Solartechnik-CPC-Sunnyline EN tedoc 04-02-2016 Layout 1 · MORNING 365 DAYS AFTERNOON Your boiler will have a longer break due to the efficient use of the sun! The angle factor is](https://reader034.vdocuments.us/reader034/viewer/2022050222/5f67f4ebf0b32b31ef0d304e/html5/thumbnails/22.jpg)
SOLARFOCUScombines
INNOVATIVE TECHNOLOGIES+
MODERN PRODUCTION!
All our work is done by people for whom the environment and the use of renewable technology is a priority.
All solar panels and biomass boilers are manufactured at SOLARFOCUS headquarters in St. Ulrich near Steyr.
THE PHILOSOPHY
Conscious sustainabilitySOLARFOCUS is proud to shape the future in a way that
serves people‘s needs and at the same time preserves
the environment.
Strong partnersSuccess requires strong partners. SOLARFOCUS pas-
ses on its extensive know-how directly to heating engi-
neers and installers. This enables proper planning and
optimal installation of the heating system is guaranteed.
22
The production – ENVIRONMENT – FUTURE
Solartechnik-CPC-Sunnyline_EN_ tedoc_04-02-2016_Layout 1 04.02.2016 14:35 Seite 22
![Page 23: Solartechnik-CPC-Sunnyline EN tedoc 04-02-2016 Layout 1 · MORNING 365 DAYS AFTERNOON Your boiler will have a longer break due to the efficient use of the sun! The angle factor is](https://reader034.vdocuments.us/reader034/viewer/2022050222/5f67f4ebf0b32b31ef0d304e/html5/thumbnails/23.jpg)
23
makes you independent
INNOVATION –
ECONOMY –
QUALITY
SOLARFOCUS is shaping the future with products that
serve people and help the environment!
SOLARFOCUS is concerned with the development,
construction and distribution of solar and environmen-
tal technology products, with a focus on:
Biomass heating,
Solar thermal systems,
Storage technology,
Fresh water tecnology
SOLARFOCUS is one step ahead: thanks to ongoing
research, development and cooperation with renowned
research institutes and partners, we have been able to
show dynamic company development. Our products
are only available from specialist dealers across
Europe. Ongoing training and seminars with our
partners ensure that plant operators receive project-
oriented advice and professional plant installation.
AWARDS such as:
l Young Entrepreneur’s Award
l Austrian Innovation Award 1995
l Golden „Pegasus“ Business Award
l Nominated for National Award for Innovation
l Voted Leading Upper Austrian Company for
Brilliant Business Ideas
l Upper Austrian Environmental Protection Award
l „Energy Genie“ Innovation Award 2003
l „Haustechnik Award“ HVAC Award 2004
l „Energy Genie“ Innovation Award 2011
l „FORLENER“ Italian Innovation Award for
energy-saving and eco-friendly technologies 2012
l Polish Innovation Award Zloty Medal” 2012 and 2013
l Slovenian Innovation Award 2014
l Best Business Award 2014
l UK Build It Award 2015
... and many more attest to our philosophy.
Solartechnik-CPC-Sunnyline_EN_ tedoc_04-02-2016_Layout 1 04.02.2016 14:35 Seite 23
![Page 24: Solartechnik-CPC-Sunnyline EN tedoc 04-02-2016 Layout 1 · MORNING 365 DAYS AFTERNOON Your boiler will have a longer break due to the efficient use of the sun! The angle factor is](https://reader034.vdocuments.us/reader034/viewer/2022050222/5f67f4ebf0b32b31ef0d304e/html5/thumbnails/24.jpg)
Your specialised dealer
SOLARFOCUS GmbH Werkstraße 1 A-4451 St. Ulrich/Steyr
e-mail: [email protected] Tel.: +43 (0) 7252 / 50 002 - 0
web: www.solarfocus.com Fax: +43 (0) 7252 / 50 002 - 10
Subject to technical modifications, typesetting and printing errors. The images used are symbolic photos. All use is prohibited without the written consent of the copyright holder SOLARFOCUS.
makes you independent
Tested state-of-the-art technology – EN ISO 9001 certified
acco
rding to
guarantee
pass
yearsyears
Guarantee
Guarantee
Guarantee
Guarantee
PREMIUM
PREMIUM
up toup to
Everything from one supplier
Solar systems − Biomass heating − Storahe technology − Fresh water technology
Innovative products, which protect theenvironment and relieve the purse.
© S
OLA
RF
OC
US
Gm
bH
| 0
2/2
016
EN 303-5
CEN/TC 57
Solartechnik-CPC-Sunnyline_EN_ tedoc_04-02-2016_Layout 1 04.02.2016 14:35 Seite 24