solar inverter product overview · 2020-03-24 · residential, commercial and utility-scale solar...
TRANSCRIPT
www.solar-inverter.com
Solar Inverter Product Overview
Solar inverters, monitoring and supportfor PV installations of all sizes
MyDeltaSolar CloudMonitoring for your PV installation
MyDeltaSolar Cloud is a cloud-based monitoring system that allows the solar inverter owner to register their PV plant online to view the status anytime and anywhere. This ensures reliable operation and a maximum return on your investment in your solar system.
The application can be used with Delta inverters featuring Wi-Fi communication such as the Flex-series single-phase inverters and RS485 inverters via DC1.
With its user-friendly Internet application, which provides a quick overview of the most important values, the yield and the system status, the MyDeltaSolar Cloud monitoring is ideal for residential or small commercial PV systems.
Real-time performance data is gathered from the inverters, sent over the internet, and presented on your computer or web-enabled device with easy to read graphs.
Automated email alerts can be configured to provide im-mediate notification of any issues, avoiding downtime on your solar investment.
DC1Load
LAN
DC PowerAC Grid
Wi-Fi
Routerlnternet
LAN
MyDeltaSolarCloud
Wi-Fi
Ethernetor
Wi-Fi
RS485
RS485
Wi-Fi
MyDeltaSolar AppMonitoring app for inverters with Wi-Fi communication or RS485 via DC1
MyDeltaSolar App uses integrated Wi-Fi communication in the Flex-series to connect to the inverter for commission-ing and monitoring of your PV plant. The app can be used with RS485 inverters as well via the DC1 and is available for Android and iOS mobile devices.
+MyDeltaSolar
APP
Initial Installation
System Monitoring
InverterSettings
Residential, Commercial and Utility-ScaleSolar Inverters For All Sizes Of PV Systems
RESIDENTIAL
COMMERCIAL
UTILITY-SCALE
H2.5 / H3A / H4A / H5A
M10A M15A / M20A M30A M50A M70A M88H
M50A M70A M88H M125HV
M6A / M8A / M10A
About DeltaSmarter. Greener. Together.
H2.5 Flex H3A Flex H4A Flex H5A FlexInput (DC)
Nominal power (W) 2600 3190 4320 5280
Voltage range (V) 30 ... 500 30 ... 600
MPP operating voltage range (V) 30 ... 500 30 ... 550
Voltage range for max. power (V) 240 ... 470 180 ... 500 240 ... 500 1)
Max. number of MPP Trackers 1 2 2)
Output (AC)
Number of phases 1
Nominal apparent power (VA) 3) 2500 3000 4000 5000 4)
Voltage range (V) 5) 230 (-20% / +22 %), 1 phase (L, N, PE)
Nominal frequency (Hz) 5) 50 / 60 ± 5
Power factor adjustable 0.8 capacitive ... 0.8 inductive
Additional Information
Max. efficiency (%) 97.5 98.3
Efficiency EU (%) 96.8 98.0
Operating temperature (°C) -25 ... +60 (full power up to +40 °C)
Protection degree IP651) When operated with maximum current2) Parallel inputs: 1 MPP Tracker, Separate inputs: 2 MPP Trackers, input load: symmetrical and asymmetrical (for H3A Flex / H4A Flex: 0/100 %, for H5A Flex: 4/96 %)3) Cos Phi = 1 (VA = W)4) 4.6 kW for Germany5) AC voltage and frequency range will be programmed according to the individual country requirements
H2.5 Flex H3A Flex / H4A Flex H5A Flex
2.5 kVA - 5 kVA
4 Wi-Fi comm.
4 Ultra Low Startup Voltage
NEW!4 Wi-Fi comm.
4 Ultra Low Startup Voltage
NEW!4 Wi-Fi comm.
4 Ultra Low Startup Voltage
NEW!
Delta, founded in 1971, is a global provider of power and thermal management solutions and a major player in several product seg-ments such as industrial automation, displays, and networking. Its mission statement, “To provide innovative, clean and energy-ef-ficient solutions for a better tomorrow,” focuses on addressing key environmental issues such as global climate change. As an energy-saving solutions provider with core competencies in power electronics and innovative research and development, Delta’s business domains include Power Electronics, Automation, and Infrastructure. Delta has 169 sales offices, 69 R&D centers and 37 manufacturing facilities worldwide.
Throughout its history, Delta has received many global awards and recognition for its business achievements, innovative technologies and dedication to corporate social responsibility. Since 2011, Delta
has been listed on the DJSI World Index of Dow Jones Sustai-nability™ Indices for 8 consecutive years. In 2017, Delta was selected by CDP (formerly the Carbon Disclosure Project) for its Climate Change Leadership Level for the 2nd consecutive year.
Maximum profitability
Delta solar inverters achieve a peak efficiency of up to 99.2 % and offer one of the largest operating temperature ranges available. Full output up to 50 °C ambient temperature to maximise energy efficiency and ensure maximum profitability.
Leading-edge characteristics
Some of the advanced characteristics include anti-PID (Potential Induced Degradation) to help protect solar module cells from degrading perfor-mance, nighttime reactive power and replaceable Type 1 & 2 SPDs. Delta M70A inverters provide I-V
curve measurement points on each individual string for creating graphs from this data.
Aluminium housing
The aluminium housing of Delta solar inverters ensure long lasting protection against moisture and corrosion. The dust-proof, completely shock-proof housing protects the electronics of the solar inverter from water spray from all directions. This
means that it can be installed in protected outdoor areas, damp basements and areas with a high level of dust (agriculture).
Long lifetime
Delta inverters have a very long lifetime thanks to the durable aluminum housing and high qual-ity robust electronics that are employed in their design. Continuous product improvement is ensured due to comprehensive testing during
product development and in production.
Delta Solar InvertersExceptional performance and advanced features
6 kVA - 10 kVA
M6A M8A M10AInput (DC)
Nominal power (W) 6600 8800 11000
Voltage range (V) 200 ... 1000
MPP operating voltage range (V) 200 ... 1000
Voltage range for max. power (V) 1) 315 ... 850 415 ... 800
Max. number of MPP Trackers 2 2)
Output (AC)
Number of phases 3
Nominal apparent power (VA) 3) 6000 8000 10000
Voltage range (V) 4) 230 ± 20 % / 400 VAC ± 20 %; 3 phase + PE or 3 phase + N + PE
Nominal frequency (Hz) 4) 50 / 60 ± 5
Power factor adjustable 0.8 capacitive ... 0.8 inductive
Additional Information
Max. efficiency (%) 98.3 98.3 98.3
Efficiency EU (%) 97.6 97.9 98.0
Operating temperature (°C) -25 ... +60 (full power up to +40 °C)
Protection degree IP651) When operated with balanced DC inputs (50/50 %)2) Parallel inputs: 1 MPP Tracker, Separate inputs: 2 MPP Trackers, input load: symmetrical and asymmetrical (for M6A, M8A, M10A: 40/60 %)3) Cos Phi = 1 (VA = W)4) AC voltage and frequency range will be programmed according to the individual country requirements
M6A M8A M10A
4 Wi-Fi and RS-485 Included
NEW!4 Wi-Fi and RS-485 Included
NEW!4 Wi-Fi and RS-485 Included
NEW!
15 kVA - 50 kVA
Strong and reliable company with local presence
� Experienced contact partners in your area and in your language
� Knowledge of the local grid access conditions
Highly reliable products with extensive testing and continu-ous improvement
� Extensively tested products in extreme conditions
� Robust electronics and die-cast aluminum chassis
� IP65 protection class for outdoor installation
The Delta AdvantageMore than just great products
Extensive support for sales partners, installers, and plant operators
� Delta Solar Team offers inverter training courses which can be run on your premises upon request
� Dedicated Solar Support Hotline which is there when you need help
Solar inverters with exceptional power density and advanced features
� M125HV/M88H CF/M70A have integrated string monitoring
� M30A/M50A/M88H CF with built-in Type II AC & DC SPDs & string fuses
� M125HV has integrated 1500Vdc, Type II AC & DC SPDs & string fuses
World leadingpeak efficiency
99.2%
M15A M20A M30A M50A
M15A M20A M30A M50AInput (DC)
Nominal power (W) 1) 15600 20600 31500 52000
Voltage range (V) 200 ... 1000 200 ... 1100 2)
MPP operating voltage range (V) 200 ... 1000
Voltage range for max. power (V) 3) 355 ... 820 470 ... 820 520 ... 800
Max. number of MPP Trackers Parallel inputs: 1 MPP Tracker, Separate inputs: 2 MPP Trackers,input load: symmetrical and asymmetrical (for M15A / M20A / M30A: 33/67 %; for M50A: 40/60 %)
Output (AC)
Number of phases 3
Nominal apparent power (VA) 4) 15000 20000 30000 50000
Voltage range (V) 5) 230 ± 20 % / 400 VAC ± 20 %; 3 phase + PE or 3 phase + N + PE
Nominal frequency (Hz) 5) 50 / 60 ± 5
Power factor adjustable 0.8 capacitive ... 0.8 inductive
Additional Information
Max. efficiency (%) 98.3 98.4 98.5 98.6
Efficiency EU (%) 97.9 98.1 98.2 98.4
Operating temperature (°C) -25 ... +60 6)
Protection degree IP651) Max. power per DC input with asymmetrical load is: 11.1 kW for M15A; 14.8 kW for M20A; 21 kW for M30A; 34.8 kW for M50A2) For some firmware versions limited to 1000 V3) When operated with balanced DC inputs (50/50 %)4) Cos Phi = 1 (VA = W)5) AC voltage and frequency range will be programmed according to the individual country requirements6) Full nominal power without derating up to: +52 °C for M15A, +51 °C for M20A, +49 °C for M30A, +48 °C for M50A. Indicated values applicable with nominal voltages (AC and DC) and Cos Phi =1
M70A M88H M125HV
M70A M88H (400V) M88H (480V) M125HVInput (DC)Nominal power (W) 70000 70000 84000 129000
Voltage range (V) 200 ... 1100 1) 860 ... 1500MPP operating voltage range (V) 200 ... 1000 860 ... 1450Voltage range for max. power (V) 2) 460 ... 900 3) 500 ... 800 600 ... 800 860 ... 1450 4)
Max. number of MPP Trackers 6 MPP Trackers 2 MPP Trackers - M88H ST model with optional 1 MPP Tracker capability 1 MPP Tracker
Output (AC)Number of phases 3Nominal apparent power (VA) 5) 77000 VA / 77000 W
Active Power66000 80000 140000 VA / 125000 W
Active Power
Voltage range (V) 6) 400 V -20 %/+30 % Y or Δ; 3 phase + PE (Δ) or 3 phase +
N + PE (Y)400 V ±30% Y or Δ / 480 V ±20% Y or Δ 4)
3 phase + PE (Δ) or 3 phase + N + PE (Y)600V -36% / +15% 3 phase + PE (Δ)
Nominal frequency (Hz) 6) 50 / 60 ± 5Power factor adjustable 0.8 capacitive ... 0.8 inductiveAdditional InformationMax. efficiency (%) 98.8 98.8 99.2Efficiency EU (%) 98.4 98.5 98.6 Operating temperature (°C) -25 ... +60 7)
Protection degree IP651) For some firmware versions limited to 1000 V2) When operated with balanced DC inputs (50/50 %)3) Ambient temperature: < 35°C: 460...900 V, < 40°C: 460...800 V or < 50°C: 520...700 V4) Ambient temperature: < 0°C: 860...1450 V, < 25°C: 860...1350 V or < 40°C: 860...1250 V5) Cos Phi = 1 (VA = W)6) AC voltage and frequency range will be programmed according to the individual country requirements7) Full nominal power without derating up to: +50°C for M70A, +40°C for M88H, +50°C for M125HV. Indicated values applicable with nominal voltages (AC and DC) and Cos Phi =1
70 kVA - 140 kVA
� Collect all relevant data from your Delta inverters
� Manage multiple PV plants in the MyDeltaSolar Cloud
� Connect to your Delta inverters via RS485 or Wi-Fi
� Compatible with third-party monitoring solutions
� Digital inputs, dry contacts, dynamic power limitation
Monitoring Your SavingsDC1 - Data Collector
NEW!4 140kVA
4 1500Vdc
NEW!4 6 MPPTs
4 Wireless comm.
+MyDeltaSolar
APP
GENERAL DC1
Supply voltage (RS485 plug)
9 ... 25 VDC / 5 W (from communication card of inverter or Delta DIN rail Power Supply DRC-12V10W1AZ or equivalent)
Supply voltage (Micro-USB) 5 VDC / 5 W
Protection degree IP20
Relative humidity 30 ... 85%Operating temperature range -25 ... +55 °C
Storage temperature range -30 ... +70 °C
Maximum operating altitude 2000 m
Max. number of inverters RS485: 30; Wi-Fi: 9Connectors RS485, Wi-Fi, Micro-SD, Extension port, USB 2.0
Wi-Fi DC1
Network standardsIEEE 802.11b IEEE 802.11g IEEE 802.11n
Data ratesIEEE 802.11b: 6.5 ... 150 Mbps IEEE 802.11g: 6 ... 54 Mbps IEEE 802.11n: 1 ... 1 Mbps
Modulation OFDM (BPSK), QPSK, 16-QAM, 64-QAM; 802.11b (CCK / DSSS)
Bandwidth 20 MHz / 40 MHz
November 14, 2019 - All information and specifications are subject to change without notice.
www.solar-inverter.com
Good service is very important. Therefore Delta provides reliable, flexible and competent support. Customer sat-isfaction and fast response times are not just words for Delta. Delta cares for partners and customers during the complete lifetime of the product.
Our highly motivated Solar Team supports Delta’s customers via our dedicated Solar Support Hotline which is there when you need help.
If necessary, you can receive local support from our service teams. Exchange units and components are avail-able within two working days.
Do you need detailed information about the solar inverter; No problem! Our Delta Solar Team offers inverter training courses which can be run either on our premises or on your premises on request.
Reliable, Flexible and Competent
Sales Contact
United [email protected] 051 4280 (Free Call)
Other European [email protected]+49 7641 455 547
Delta Service & Support