snubbing services - basic energy services · and cost-effective snubbing services to operators...

4
At Basic Energy Services, we are committed to providing safe, highly efficient and cost-effective snubbing services to operators throughout North America. We respond to the needs of our customers with the top industry-leading equipment available in the market, operated by highly trained, experienced professionals who meet or exceed all safety certifications and requirements. Basic Advantages: • Comprehensive Range of Offerings • Seasoned, Highly Trained Personnel • Effective Use of Cutting-edge Technologies • Commitment to Safety First Applications: • Wells with fragile formations that could suffer damage from completion fluids. • Wells perforated in underbalanced conditions. • Well control fluids too costly to achieve balance conditions • Running and pulling completions under pressure. OUR LIFE’S WORK IS THE LIFE OF THE WELL. Trusted Expertise, Proven Reliability. Snubbing Services

Upload: letram

Post on 07-Sep-2018

257 views

Category:

Documents


6 download

TRANSCRIPT

Page 1: Snubbing Services - Basic Energy Services · and cost-effective snubbing services to operators throughout North America. ... 120K Snubbing Unit 120K Snubbing Unit Specifications Height

At Basic Energy Services, we are committed to providing safe, highly efficient and cost-effective snubbing services to operators throughout North America.

We respond to the needs of our customers with the top industry-leading equipment available in the market, operated by highly trained, experienced professionals who meet or exceed all safety certifications and requirements.

Basic Advantages: • Comprehensive Range of Offerings

• Seasoned, Highly Trained Personnel

• Effective Use of Cutting-edge Technologies

• Commitment to Safety First

Applications: • Wells with fragile formations

that could suffer damage from

completion fluids.

• Wells perforated in

underbalanced conditions.

• Well control fluids too

costly to achieve

balance conditions

• Running and pulling

completions under pressure.

OUR LIFE’S WORK IS THE LIFE OF THE WELL.™

Trusted Expertise, Proven Reliability.

Snubbing Services

Page 2: Snubbing Services - Basic Energy Services · and cost-effective snubbing services to operators throughout North America. ... 120K Snubbing Unit 120K Snubbing Unit Specifications Height

Snubbing Units

 

 

 

 

 

 

 

 

 

 

 

60K  Snubbing  Unit  Specifications  Height   12ft  Work  Platform     7  ft      x    8  ft      

Weight   12,500lbs                            Jack  Stroke     6ft                  Bore   7.0625in  Snub  Force   19,650lbs  @  2,500psi  Slips   Oil  Country  HD  Load  Rating  250,000lbs  Tubing  Range     1.05-­‐5.5in    Max  Bowl  Opening       7.125in  Annular  BOP       7.0625in  BOP  Working  Pressure     0-­‐5,000psi  1-­‐Single  Ram             7.0625in  Ram  Working  Pressure   5,000psi          

 

60K Snubbing Unit 60K Snubbing Unit SpecificationsHeight 12 ft

Work Platform 7 ft x 8 ftWeight 12,500 lbs

Jack Stroke 6 ftBore 7.0625 in

Snub Force 19,650 lbs @ 2,500 psi

Slips Oil Country HD Load Rating 250,000 lbs

Tubing Range 1.05-5.5 in Max Bowl Opening 7.125 inAnnular BOP I.D. 7.0625 in

Annular BOP Working Pressure 0-5,000 psi1-Single Ram I.D. 7.0625 in

Ram BOP Working Pressure 5,000 psi

80K Snubbing Unit 80K Snubbing Unit SpecificationsHeight 12 ft 6 inWeight 16,500 lbs

Jack Stroke 6 ftBore 7.0625 inSnub 40,000 lbs

Slips Oil Country HD Load Rating 250,000 lbs

Tubing Range 1.05-5.50 in

Max Bowl Opening 7.125 inAnnular BOP I.D. 7.0625 in

Annular BOP Working Pressure 0-5,000 psi1-Single Ram BOP I.D. 7.0625 in

Ram BOP Working Pressure 5,000 psi

120K Snubbing Unit 120K Snubbing Unit SpecificationsHeight 13 ft 8 inWeight 24,000 lbs

Jack Stroke 10 ftBore 7.0625 inSnub 60,000 lbs

Slips Oil Country HD Load Rating 250,000 lbs

Tubing Range 1.05-5.50 inMax Bowl Opening 7.125 inAnnular BOP I.D. 7.0625 in

Annular BOP Working Pressure 5,000 psi2-Double Ram BOP I.D. 7.0625 in

Ram BOP Working Pressure 5,000 psi

Leveraging our fleet snubbing units, Basic provides snubbing services

to allow “live-well” completion and workover operations. Our snubbing

services are used to enhance production of oil and gas wells in both

conventional and unconventional fields.

Page 3: Snubbing Services - Basic Energy Services · and cost-effective snubbing services to operators throughout North America. ... 120K Snubbing Unit 120K Snubbing Unit Specifications Height

150K Snubbing Stand Alone Unit 150K Snubbing Unit Specifications

Height 17 ft 9 in (Jack Assembly Only)Weight 15,000 lbs (Jack Assembly Only)

Jack Stroke 10 ftBore 7.0625 in

Tube Guide Bore 5.0 inSnub 75,000 lbsLift 150,000 lbsSlips SB350 rated for 150,000 lbs

Tubing Range 1.00-3.50 inMax Bowl Opening 6.00 inAnnular BOP I.D. 7.0625 in

Annular BOP Working Pressure 5,000 psi

BOP Stack Weight 9,000 lbs (BOP Assembly Only)

2-Double Ram Stripping Stack I.D. 7.0625 in

BOP Working Pressure 5,000 psi

170K Snubbing Unit 170K Snubbing Unit SpecificationsHeight 17.1 ftWeight 28,000 lbs

Jack Stroke 10 ftBore 7.0625 inSnub 94,248 lbs

Slips Oil Country HD Load Rating 250,000 lbs

Tubing Range 1.05-5.50 inMax Bowl Opening 7.125 inAnnular BOP I.D. 7.0625 in

Annular BOP Working Pressure 5,000 psi

2-Single Ram Stripping Stack I.D. 7.0625 in

Ram BOP Working Pressure 10,000 psi and 15,000 psi

225K Snubbing Stand Alone Unit 225K Snubbing Unit Specifications

Height 17 ft 9 in (Jack Assembly Only)Weight 22,000 lbs (Jack Assembly Only)

Jack Stroke 12 ftBore 7.0625 in

Tube Guide Bore 5.0 inSnub 112,000 lbsLift 225,000 lbs

Slip Bowl Rating NU 550FO Rated for 225,000 lbs

Tubing Range 2.375-5.50 in Max Bowl Opening 8.25 in

Rotary 7,000 ft/lbs, 2-speed 100/50 RPM

Annular BOP I.D. 7.0625 inAnnular BOP Working Pressure 5,000 psi

BOP Stack Weight 17,000 lbs2- Single Ram Stripping Stack I.D. 7.0625 in

Ram BOP Working Pressure 10,000 psi

The self-contained 170K unit is configured with a low profile BOP stack assembly which shortens the operations height for tubular handling and allows for faster trip times. Only one flange is required to be connected to the 170K rig assist unit which can be rigged up in less than 60 minutes.

Page 4: Snubbing Services - Basic Energy Services · and cost-effective snubbing services to operators throughout North America. ... 120K Snubbing Unit 120K Snubbing Unit Specifications Height

Safety First, Always. At Basic Energy Services, the safety of personnel always comes first. That’s why

we’ve built outstanding features into our snubbing units that ensure safer handling,

rigging and operation.

Benefits: • Increased visibility and communication between the operator and the driller

• The ideal tool for stripping short or long drilling strings

• Unit can safely complete most jobs currently being performed with larger snubbing units

• Power swivel operations are safer because of lower rig-up height

Our Snubbing Service Locations. With Snubbing Services locations in Texas; Pennsylvania; Oklahoma; Williston, ND;

and Arkansas, Basic is responsive toward helping customers maintain the efficiency of their wells. With Basic, you get the best people and the best equipment for the job, every time.

www.basicenergyservices.com

Basic Energy Services2618 US 287 S. Decatur, TX 76234Tel: 940.626.8297

Basic Energy Services5209 Estes PkwyLongview, TX 75603Tel: 903.295.0817

Basic Energy Services940 Runway Dr.Conway, AR 72032Tel: 501.329.5975

Basic Energy Services 14082 W Front St,Williston, ND 58801Tel: 701.774.0127

Equipment Locations:

Basic Energy Services 141 Jefferson Rd.Waynesburg, PA 15370Tel: 724.627.0770

Basic Energy Services 7302 N. Highway 81Duncan, OK 73533Tel: 580.252.6200