smoke generation for certification ground and … · smoke generation for certification ground and...

23
Smoke Generation for Certification Ground and Flight Tests - BCECS2 - Ref. X2616PR0509735 - Iss. 2 Nov 2005 International Aircraft Systems Fire Protection Working Group Meeting Smoke Generation for Certification Ground and Flight Tests Definition of Smoke Amounts Presented by Kai Behle Airbus Deutschland GmbH BCECS2, Fire Protection Contact: [email protected]

Upload: vuongthuan

Post on 01-Sep-2018

227 views

Category:

Documents


0 download

TRANSCRIPT

Page 1: Smoke Generation for Certification Ground and … · Smoke Generation for Certification Ground and Flight Tests ... •Lab Test Campaign ... Smoke Generation for Certification Ground

Smoke Generation for Certification Ground and Flight Tests - BCECS2 - Ref. X2616PR0509735 - Iss. 2

Nov 2005International Aircraft Systems Fire Protection Working Group Meeting

Smoke Generation for Certification Ground and Flight Tests

Definition of Smoke Amounts

Presented by

Kai Behle

Airbus Deutschland GmbHBCECS2, Fire Protection

Contact: [email protected]

Page 2: Smoke Generation for Certification Ground and … · Smoke Generation for Certification Ground and Flight Tests ... •Lab Test Campaign ... Smoke Generation for Certification Ground

Nov 2005Smoke Generation for Certification Ground and Flight Tests - BCECS2 - Ref. X2616PR0509735 - Iss. 2 Page 2© A

IRBU

S D

EUTS

CH

LAN

D G

MB

H.

All r

ight

s re

serv

ed. C

onfid

entia

l and

pro

prie

tary

doc

umen

t.

Overview

• Theoretical Background: Requirements and Guidelines• Flashback: “FAA-Powder”• Today: Paraffin Oil Smoke Generator• Smoke Amounts - Airbus Method (linked to TSO C1d)

• Lab Test CampaignSet-UpResults (Smoke Generator and flaming Resin Block)

• Summary / Conclusion

Page 3: Smoke Generation for Certification Ground and … · Smoke Generation for Certification Ground and Flight Tests ... •Lab Test Campaign ... Smoke Generation for Certification Ground

Nov 2005Smoke Generation for Certification Ground and Flight Tests - BCECS2 - Ref. X2616PR0509735 - Iss. 2 Page 3© A

IRBU

S D

EUTS

CH

LAN

D G

MB

H.

All r

ight

s re

serv

ed. C

onfid

entia

l and

pro

prie

tary

doc

umen

t.

Theoretical Background: Requirements

JAR‘s (FAR’s are similar):

JAR 25.0858 (a): The detection system must provide a visual indication to the flight crew within one minute after the start of a fire.

JAR 25.0858 (b): The system must be capable of detecting a fire at a temperature significantly below that at which the structural integrity of the aeroplane is substantially decreased.

Page 4: Smoke Generation for Certification Ground and … · Smoke Generation for Certification Ground and Flight Tests ... •Lab Test Campaign ... Smoke Generation for Certification Ground

Nov 2005Smoke Generation for Certification Ground and Flight Tests - BCECS2 - Ref. X2616PR0509735 - Iss. 2 Page 4© A

IRBU

S D

EUTS

CH

LAN

D G

MB

H.

All r

ight

s re

serv

ed. C

onfid

entia

l and

pro

prie

tary

doc

umen

t.

Theoretical Background: Guidelines

AC 25-9A - Extract about smoke amounts and generation:

§10 a (2) A smouldering fire producing a small amount of smoke in conjunction with the applicable detection time (…) could be detected early enough to ensure that the fire and smoke procedures would be effective. Subjective judgment, considering the failure, size of compartment (…) is needed to assess the significance of a small amount of smoke.

(3) (…) theatrical smoke generators are acceptable for detection tests if the smoke generator is operated for limited intervals to limit the amount of smoke generated. (…)

Page 5: Smoke Generation for Certification Ground and … · Smoke Generation for Certification Ground and Flight Tests ... •Lab Test Campaign ... Smoke Generation for Certification Ground

Nov 2005Smoke Generation for Certification Ground and Flight Tests - BCECS2 - Ref. X2616PR0509735 - Iss. 2 Page 5© A

IRBU

S D

EUTS

CH

LAN

D G

MB

H.

All r

ight

s re

serv

ed. C

onfid

entia

l and

pro

prie

tary

doc

umen

t.

Flash-Back: Smoke Generation with “FAA-powder“

• In FAA technical report FAA-ADS-73 (dated 1966) a mixture of each 50% potassium chlorate and lactose is proposed to be used for certification tests on smoke detection installations.

• Powder amounts to be used shall depend on:Compartment sizeAir flow rate

• This mixture was used within Airbus programs until mid of the nineties. For several disadvantages, in particular heavy sputtering and emission of toxic gases during the burning process, a new smoke generation method needed to be developed.

Page 6: Smoke Generation for Certification Ground and … · Smoke Generation for Certification Ground and Flight Tests ... •Lab Test Campaign ... Smoke Generation for Certification Ground

Nov 2005Smoke Generation for Certification Ground and Flight Tests - BCECS2 - Ref. X2616PR0509735 - Iss. 2 Page 6© A

IRBU

S D

EUTS

CH

LAN

D G

MB

H.

All r

ight

s re

serv

ed. C

onfid

entia

l and

pro

prie

tary

doc

umen

t.

Today: Paraffin Oil Smoke Generator (used by Airbus)

A paraffin oil smoke generator was developed (Aerotec AX 1000 derivate ZZ103) in 1995 (refer to P26RP0301705 Edition 1)

Page 7: Smoke Generation for Certification Ground and … · Smoke Generation for Certification Ground and Flight Tests ... •Lab Test Campaign ... Smoke Generation for Certification Ground

Nov 2005Smoke Generation for Certification Ground and Flight Tests - BCECS2 - Ref. X2616PR0509735 - Iss. 2 Page 7© A

IRBU

S D

EUTS

CH

LAN

D G

MB

H.

All r

ight

s re

serv

ed. C

onfid

entia

l and

pro

prie

tary

doc

umen

t.

Smoke Generator Functioning Principle

Upward deflection of simulated smoke is necessary to generate buoyancy

Principle: Paraffine oil is pre-heated and directed towards a heated deflection plate directing the smoke upwards:

Page 8: Smoke Generation for Certification Ground and … · Smoke Generation for Certification Ground and Flight Tests ... •Lab Test Campaign ... Smoke Generation for Certification Ground

Nov 2005Smoke Generation for Certification Ground and Flight Tests - BCECS2 - Ref. X2616PR0509735 - Iss. 2 Page 8© A

IRBU

S D

EUTS

CH

LAN

D G

MB

H.

All r

ight

s re

serv

ed. C

onfid

entia

l and

pro

prie

tary

doc

umen

t.

Paraffin Oil Smoke Generator (continued)

Different smoke generation programs were developed to represent various “FAA-powder“ amounts. E. g. the following programs were used during A318 ground- and flight-tests:

6 s 6 s 6 s 6 s3 s 2 s 1 s

Emission Pause Emission Pause Emission Pause Emission

10 s 4 s 3 s 3 s5 s 3 s 2 s

Emission Pause Emission Pause Emission Pause Emission

Startt=0

t=10s t=20s t=30s

Program 5

Program 6

Page 9: Smoke Generation for Certification Ground and … · Smoke Generation for Certification Ground and Flight Tests ... •Lab Test Campaign ... Smoke Generation for Certification Ground

Nov 2005Smoke Generation for Certification Ground and Flight Tests - BCECS2 - Ref. X2616PR0509735 - Iss. 2 Page 9© A

IRBU

S D

EUTS

CH

LAN

D G

MB

H.

All r

ight

s re

serv

ed. C

onfid

entia

l and

pro

prie

tary

doc

umen

t.

Paraffin Oil Smoke Generator (continued)

Smoke Generator Operation:Both depicted sequences show that smoke is not permanently generated. In both cases, smoke generation is stopped after 30 seconds.

⇒ Therefore, AC25-9A §10 a (3) is fulfilled.

Page 10: Smoke Generation for Certification Ground and … · Smoke Generation for Certification Ground and Flight Tests ... •Lab Test Campaign ... Smoke Generation for Certification Ground

Nov 2005Smoke Generation for Certification Ground and Flight Tests - BCECS2 - Ref. X2616PR0509735 - Iss. 2 Page 10© A

IRBU

S D

EUTS

CH

LAN

D G

MB

H.

All r

ight

s re

serv

ed. C

onfid

entia

l and

pro

prie

tary

doc

umen

t.

Smoke Amounts – Airbus Method (linked to TSO C1d)

Light obscuration (in %/m or %/ft) is the physical parameter for assessing performance of optical smoke detectors

TSO C1d requirement about required optical smoke detectors sensitivity: Alarm threshold setting: 12.5 %/m – 81 %/m light obscuration

Airbus method: use smoke amount leading to approx. 13%/m light obscuration (with ventilation switched off)

after 30s and at one third of the compartment length (for LR and A380 compartments) with smoke generator located at FWD compartment wall

Determination of smoke generator setting in lab testcampaign

Page 11: Smoke Generation for Certification Ground and … · Smoke Generation for Certification Ground and Flight Tests ... •Lab Test Campaign ... Smoke Generation for Certification Ground

Nov 2005Smoke Generation for Certification Ground and Flight Tests - BCECS2 - Ref. X2616PR0509735 - Iss. 2 Page 11© A

IRBU

S D

EUTS

CH

LAN

D G

MB

H.

All r

ight

s re

serv

ed. C

onfid

entia

l and

pro

prie

tary

doc

umen

t.

Smoke Amounts – Airbus Method (continued)

Airbus proposal as presented during Fire Protection Workshop held in Renton in Sep 2004

September 2004Smoke Generation Methods for Certification Tests Page 8© A

IRB

US D

EUT

SCH

LAN

D G

mbH

. All

right

s re

serv

ed. C

onfid

entia

l and

pro

prie

tary

doc

umen

t.

Proposal for Smoke Det. Response Time Tests

1. Step: Determine appropriate Smoke Amount and Smoke Generator Position in Lab- or Ground Test

Example: Top View of Small Lower Deck Cargo Compartment

Smoke Generator Reference Optical Density Meter

FWD

l

l/2

September 2004Smoke Generation Methods for Certification Tests Page 9© A

IRB

US D

EUT

SCH

LAN

D G

mbH

. All

right

s re

serv

ed. C

onfid

entia

l and

pro

prie

tary

doc

umen

t.

Proposal for Smoke Det. Response Time Tests

2. Step: Conduct Test on Aircraft with Smoke Amount and Generator Position determined in Step 1

Example: Top View of Small Lower Deck Cargo Compartment

Example of Smoke Detector Cavity Installation

Smoke Generator

FWD

Note: Distance of l/2 between smoke generator and optical density meter was proposed for “small“ (e.g. single aisle airplane cargo compartments)

Page 12: Smoke Generation for Certification Ground and … · Smoke Generation for Certification Ground and Flight Tests ... •Lab Test Campaign ... Smoke Generation for Certification Ground

Nov 2005Smoke Generation for Certification Ground and Flight Tests - BCECS2 - Ref. X2616PR0509735 - Iss. 2 Page 12© A

IRBU

S D

EUTS

CH

LAN

D G

MB

H.

All r

ight

s re

serv

ed. C

onfid

entia

l and

pro

prie

tary

doc

umen

t.

Lab Test Campaign – Set-Up

Measurement campaign was conducted with smoke detector supplier Siemens/FSimilar geometries of A380 FWD LDCC and Mock-up:

1.8m1.8mHeight4.6m4.2mWidth14.4m17.4mLength

Mock-UpA380 FWD LDCC

Reference measurements taken by opical density meter

Page 13: Smoke Generation for Certification Ground and … · Smoke Generation for Certification Ground and Flight Tests ... •Lab Test Campaign ... Smoke Generation for Certification Ground

Nov 2005Smoke Generation for Certification Ground and Flight Tests - BCECS2 - Ref. X2616PR0509735 - Iss. 2 Page 13© A

IRBU

S D

EUTS

CH

LAN

D G

MB

H.

All r

ight

s re

serv

ed. C

onfid

entia

l and

pro

prie

tary

doc

umen

t.

Results – Paraffin Oil Smoke Generator

Light obscuration after 30s at ≈1%/m, ≈13%/m reached after 32s, Upper TSO C1d threshold not reachedHigh dynamic due to upward deflection and sinking tendency of simulated smokeSmoke generator setting in accordance with Airbus proposal

Paraffin Oil Smoke Generator - Prog 5 - Vent Off

0,00

10,00

20,00

30,00

40,00

50,00

60,00

70,00

80,00

90,00

100,00

0,0 30,0 60,0 90,0 120,0 150,0 180,0 210,0

Time [s]

Ligh

t O

bscu

rati

on [%

/m]

Light Obsc. (%/m)Upper TSO C1d limit (%/m)Lower TSO C1d limit (%/m)

Page 14: Smoke Generation for Certification Ground and … · Smoke Generation for Certification Ground and Flight Tests ... •Lab Test Campaign ... Smoke Generation for Certification Ground

Nov 2005Smoke Generation for Certification Ground and Flight Tests - BCECS2 - Ref. X2616PR0509735 - Iss. 2 Page 14© A

IRBU

S D

EUTS

CH

LAN

D G

MB

H.

All r

ight

s re

serv

ed. C

onfid

entia

l and

pro

prie

tary

doc

umen

t.

Results – Paraffin Oil Smoke Generator (cont‘d)

Light obscuration after 30s at = 0%/m, ≈13%/m reached after 34sUpper TSO C1d threshold reached after 56sHigh dynamic due to upward deflection and sinking tendency of simulated smoke

Paraffin Oil Smoke Generator - Prog 6 - Vent Off

0,00

10,00

20,00

30,00

40,00

50,00

60,00

70,00

80,00

90,00

100,00

0,0 30,0 60,0 90,0 120,0 150,0 180,0 210,0 240,0

Time [s]

Ligh

t O

bscu

rati

on [%

/m]

Light Obsc. (%/m)

Upper TSO C1d limit (%/m)

Lower TSO C1d limit (%/m)

Page 15: Smoke Generation for Certification Ground and … · Smoke Generation for Certification Ground and Flight Tests ... •Lab Test Campaign ... Smoke Generation for Certification Ground

Nov 2005Smoke Generation for Certification Ground and Flight Tests - BCECS2 - Ref. X2616PR0509735 - Iss. 2 Page 15© A

IRBU

S D

EUTS

CH

LAN

D G

MB

H.

All r

ight

s re

serv

ed. C

onfid

entia

l and

pro

prie

tary

doc

umen

t.

Additional Tests – Flaming Resin Block

The “resin block” has been developed by FAA Technical Center with following targets:

ReproducibilityDetectability for multi-criteria fire-/smoke sensorsProduction of comparable smoke amount as “burning suitcase“

Page 16: Smoke Generation for Certification Ground and … · Smoke Generation for Certification Ground and Flight Tests ... •Lab Test Campaign ... Smoke Generation for Certification Ground

Nov 2005Smoke Generation for Certification Ground and Flight Tests - BCECS2 - Ref. X2616PR0509735 - Iss. 2 Page 16© A

IRBU

S D

EUTS

CH

LAN

D G

MB

H.

All r

ight

s re

serv

ed. C

onfid

entia

l and

pro

prie

tary

doc

umen

t.

Additional Tests – For Reference Only

Light obscuration after 30s at ≈1%/m, ≈13%/m reached after 52sUpper TSO C1d threshold not reachedMax smoke density is maintained over 3 minutes overall smoke amount higher than that generated by smoke generator prog. 5 and 6

Flaming Resin Block - Vent Off

0,00

10,00

20,00

30,00

40,00

50,00

60,00

70,00

80,00

90,00

100,00

0,0 30,0 60,0 90,0 120,0 150,0 180,0 210,0 240,0 270,0

Time [s]

Ligh

t O

bscu

rati

on [%

/m]

Light Obsc. (%/m)Upper TSO C1d limit (%/m)

Lower TSO C1d limit (%/m)

Page 17: Smoke Generation for Certification Ground and … · Smoke Generation for Certification Ground and Flight Tests ... •Lab Test Campaign ... Smoke Generation for Certification Ground

Nov 2005Smoke Generation for Certification Ground and Flight Tests - BCECS2 - Ref. X2616PR0509735 - Iss. 2 Page 17© A

IRBU

S D

EUTS

CH

LAN

D G

MB

H.

All r

ight

s re

serv

ed. C

onfid

entia

l and

pro

prie

tary

doc

umen

t.

Influence of Ventilation Rate

All shown test results were obtained with ventilation switched off. The case with ventilation switched on might pose a serious challenge for detection of smoke generated by smoke generator program 5 or 6 as

the smoke “plumes” generated by the interval mode of the generator might be extracted before the targeted homogenous smoke distribution is reached, andthe smoke generator in program 5 or 6 stops smoke emission after 30 seconds.

When ventilation is switched on, the scenario simulated by “FAA-powder” and the paraffin oil smoke generator in program 5 & 6 might not represent a slowly evolving and continuing fire

Page 18: Smoke Generation for Certification Ground and … · Smoke Generation for Certification Ground and Flight Tests ... •Lab Test Campaign ... Smoke Generation for Certification Ground

Nov 2005Smoke Generation for Certification Ground and Flight Tests - BCECS2 - Ref. X2616PR0509735 - Iss. 2 Page 18© A

IRBU

S D

EUTS

CH

LAN

D G

MB

H.

All r

ight

s re

serv

ed. C

onfid

entia

l and

pro

prie

tary

doc

umen

t.

Influence of Ventilation Rate (continued)

For the reasons mentioned above, a different smoke generator program might be chosen with ventilation switched on. This approach is considered justified as:

It is common practice to base the smoke amount to be used on on air flow rates and compartment sizes (e.g. FAA report ADS-73 and FAA Technical Center Presentation held in Grenoble on 21 June 2004).Unlike the paraffin oil smoke generator in program 5 and 6, the flaming resin block – as well as a realistic fire scenario –continues generating smoke after 30s up to at least 180s (no generation of plumes)

The influence of ventilation will be verified in an A380 mock-up-test campaign beginning of 2006.

Page 19: Smoke Generation for Certification Ground and … · Smoke Generation for Certification Ground and Flight Tests ... •Lab Test Campaign ... Smoke Generation for Certification Ground

Nov 2005Smoke Generation for Certification Ground and Flight Tests - BCECS2 - Ref. X2616PR0509735 - Iss. 2 Page 19© A

IRBU

S D

EUTS

CH

LAN

D G

MB

H.

All r

ight

s re

serv

ed. C

onfid

entia

l and

pro

prie

tary

doc

umen

t.

Summary / Conclusion

It has been shown that AX1000 programs 5 and 6 are in line with AC25-9A Smoke generator program 5 comes closest to Airbus proposal about smoke amount determinationSmoke emission by the flaming resin block continues for at least three minutes, whereas smoke generator in program 5 and 6 stops emission after 30s (crucial for case with ventilation switched on)Smoke generator programs 5 and 6 lead to higher signal dynamics and higher short-term maximum smoke density than flaming resin blockInfluence of ventilation needs to be investigated case by case

Page 20: Smoke Generation for Certification Ground and … · Smoke Generation for Certification Ground and Flight Tests ... •Lab Test Campaign ... Smoke Generation for Certification Ground

Nov 2005Smoke Generation for Certification Ground and Flight Tests - BCECS2 - Ref. X2616PR0509735 - Iss. 2 Page 20© A

IRBU

S D

EUTS

CH

LAN

D G

MB

H.

All r

ight

s re

serv

ed. C

onfid

entia

l and

pro

prie

tary

doc

umen

t.

This document and all information contained herein is the sole property of AIRBUS DEUTSCHLAND GmbH. No intellectual property rights are granted by the delivery of this document or the disclosure of its content. This document shall not be reproduced or disclosed to a third party without the express written consent of AIRBUS DEUTSCHLAND GmbH. This document and its content shall not be used for any purpose other than that for which it is supplied.

The statements made herein do not constitute an offer. They are based on the mentioned assumptions and are expressed in good faith. Where the supporting grounds for these statements are not shown, AIRBUS DEUTSCHLAND GmbH will be pleased to explain the basis thereof.

Page 21: Smoke Generation for Certification Ground and … · Smoke Generation for Certification Ground and Flight Tests ... •Lab Test Campaign ... Smoke Generation for Certification Ground

Nov 2005Smoke Generation for Certification Ground and Flight Tests - BCECS2 - Ref. X2616PR0509735 - Iss. 2 Page 21© A

IRBU

S D

EUTS

CH

LAN

D G

MB

H.

All r

ight

s re

serv

ed. C

onfid

entia

l and

pro

prie

tary

doc

umen

t.

Backup: Dependence of Smoke Amounts on Comp. Sizes

The key-criterion for the possibility to detect smoke is smoke concentration, i.e. a certain smoke amount per defined volume

The number of smoke detectors is irrelevant for detection if the smoke density corresponding to the alarm threshold(e.g. 12.5%/m) is not reached

Adaptation of smoke amount to compartment size/volume is necessary and reflected in Airbus proposal

Due to smoke propagation time, smoke detector number to be used to monitor compartments still needs adaptation to compartment size

Page 22: Smoke Generation for Certification Ground and … · Smoke Generation for Certification Ground and Flight Tests ... •Lab Test Campaign ... Smoke Generation for Certification Ground

Nov 2005Smoke Generation for Certification Ground and Flight Tests - BCECS2 - Ref. X2616PR0509735 - Iss. 2 Page 22© A

IRBU

S D

EUTS

CH

LAN

D G

MB

H.

All r

ight

s re

serv

ed. C

onfid

entia

l and

pro

prie

tary

doc

umen

t.

Backup: Dependence of Smoke Amounts on Comp. Sizes

For the reasons mentioned above, it is necessary and common practice to vary smoke amounts in dependence of compartment sizes as mentioned in several FAA documents, for example

• FAA-ADS-73 and • FAA Technical Center Presentation held in Grenoble on

21 June 2004 (refer to FAA Technical Center homepage).

Page 23: Smoke Generation for Certification Ground and … · Smoke Generation for Certification Ground and Flight Tests ... •Lab Test Campaign ... Smoke Generation for Certification Ground

Nov 2005Smoke Generation for Certification Ground and Flight Tests - BCECS2 - Ref. X2616PR0509735 - Iss. 2 Page 23© A

IRBU

S D

EUTS

CH

LAN

D G

MB

H.

All r

ight

s re

serv

ed. C

onfid

entia

l and

pro

prie

tary

doc

umen

t.

Backup: Smoke Amounts Comparison – Ventilation OnOne flaming Resin Block in Pos 3 - Ventilation On

0,00

10,00

20,00

30,00

40,00

50,00

60,00

0,0 30,0 60,0 90,0 120,0 150,0 180,0 210,0 240,0 270,0

Time [s]

Ligh

t O

bscu

rati

on [%

/m]

0

3

6

9

12

15

18

y

Light Obsc. (%/m)

y (Ion. Ind.)

P a ra f f in O il S m o k e G e n e ra to r Z Z 1 0 1 - P ro g 6 - V e n t ila t io n O n

0 ,0 0

1 0 ,0 0

2 0 ,0 0

3 0 ,0 0

4 0 ,0 0

5 0 ,0 0

6 0 ,0 0

7 0 ,0 0

8 0 ,0 0

9 0 ,0 0

1 0 0 ,0 0

0 ,0 3 0 ,0 6 0 ,0 9 0 ,0 1 2 0 ,0 1 5 0 ,0 1 8 0 ,0 2 1 0 ,0 2 4 0 ,0 2 7 0 ,0

T im e [s ]

Ligh

t O

bscu

rati

on [%

/m]

0

3

6

9

1 2

1 5

1 8

y

L ig h t O b s c . (% / m )y ( Io n . In d .)