Site Visit Report
The site visit process is a sample on a particular day of an installation's compliance with some of its licence conditions. Where non-compliance against a particular condition has not been reported, this should not be construed to mean that there is full compliance with that condition of the licence.
Instructions and actions arising from the visit shall be addressed, or where applicable noted, by the licensee in order to ensure compliance, to improve the environmental performance of the installation and to provide clarification on certain issues.
The licensee shall take the actions specified to close out the non-compliances and observations raised in this Site Visit Report.
Licensee
Name of Installation Sperrin Galvanisers (Ireland) Limited
Licensee Sperrin Galvanisers (Ireland) Limited
Licence Register No. P0658-01
CRO Number 319411
Site Address Derryfrench, Tynagh, Galway
Site Visit Reference No. SV10472
Report Detail
Issue Date 12/10/2017
Prepared By Ken Murphy
Site Visit Detail
Date Of Inspection 26/07/2017 Announced No
Time In 09:00 Time Out 17:00
Visited by on behalf of the EPA Fitz Scientific Ltd
Licensee Personnel and Role See report
Photo Taken No Samples Taken Yes Video Taken No
Odour Assessment No
Site Visit Report - SV10472 - Sperrin Galvanisers (Ireland) Limited Page 1 of 37
![Page 2: Site Visit Report · 2017-12-12 · HCl Impinger efficiency is lower than the requirements of 95% total of concentration in the first impinger (BS EN 1911:2010 section 5.2.1.2.2)](https://reader031.vdocuments.us/reader031/viewer/2022020413/5b5e59ca7f8b9a415d8c3a19/html5/thumbnails/2.jpg)
Scope
This is a report on monitoring of emissions to air at this site. Please find the detailed technical report attached.
Media
Air
Site Areas Inspected
See Report
Documents Inspected
See Report
Site Visit Report - SV10472 - Sperrin Galvanisers (Ireland) Limited Page 2 of 37
![Page 3: Site Visit Report · 2017-12-12 · HCl Impinger efficiency is lower than the requirements of 95% total of concentration in the first impinger (BS EN 1911:2010 section 5.2.1.2.2)](https://reader031.vdocuments.us/reader031/viewer/2022020413/5b5e59ca7f8b9a415d8c3a19/html5/thumbnails/3.jpg)
Site Visit Report - SV10472 - Sperrin Galvanisers (Ireland) Limited Page 3 of 37
![Page 4: Site Visit Report · 2017-12-12 · HCl Impinger efficiency is lower than the requirements of 95% total of concentration in the first impinger (BS EN 1911:2010 section 5.2.1.2.2)](https://reader031.vdocuments.us/reader031/viewer/2022020413/5b5e59ca7f8b9a415d8c3a19/html5/thumbnails/4.jpg)
Sperrin Galvanizers LimitedDerryfrench, Tynagh, Co Galway
P0658-01CAR17-01
Emissions to AtmosphereReport No:
Report Date:
Fitz Scientific
Unit 35, Boyne Business Park, Drogheda, Co Louth
Phone: +353 41 98 45440
17/08/2017
Environmental Protection Agency
Industrial Emissions Licence: P0658-01
1 of 33Site Visit Report - SV10472 - Sperrin Galvanisers (Ireland) Limited Page 4 of 37
![Page 5: Site Visit Report · 2017-12-12 · HCl Impinger efficiency is lower than the requirements of 95% total of concentration in the first impinger (BS EN 1911:2010 section 5.2.1.2.2)](https://reader031.vdocuments.us/reader031/viewer/2022020413/5b5e59ca7f8b9a415d8c3a19/html5/thumbnails/5.jpg)
Fitz Scientific
Derryfrench, Tynagh, Co Galway
Sperrin Galvanizers Limited
Visit No: 1Year: 2017
Report for the Periodic Monitoring of Emissions to Air
Executive Summary
Licence / Permit Number:
Job Quote Number:
P0658-01
EPA17060
Operator Name:
Installation:
Phone:
Contact Name:
Sperrin Galvanizers Limited
Derryfrench, Tynagh, Co Galway
0909745804
John Moore O’Connor
Monitoring Dates:
Monitoring Organisation: Fitz Scientific
Unit 35, Boyne Business Park, Drogheda, Co. Louth, Ireland
Phone: +353 41 98 45440 / Fax: +353 41 98 46171
email: [email protected]
UKAS Registration number 2802
Report Date: 17/08/2017
Signed: ____________________________ Signed: ____________________________
-1
P0658-01Industrial Emissions Licence
Report created using QRSys version
P0658-01CAR17-01
26/07/2017
Jason McGuirk
MM14 1320
Level 2
Technician
TE1, TE2, TE3, TE4
Written By:
MCERTS Reg:
Competency:
Function:
Endorsements:
Aadil Khan
MM11 1120
Level 2
Field Services Manager
TE1, TE2, TE3, TE4
Approved By:
MCERTS Reg:
Competency:
Function:
Endorsements:
3.7 April 2017
2 of 33Site Visit Report - SV10472 - Sperrin Galvanisers (Ireland) Limited Page 5 of 37
![Page 6: Site Visit Report · 2017-12-12 · HCl Impinger efficiency is lower than the requirements of 95% total of concentration in the first impinger (BS EN 1911:2010 section 5.2.1.2.2)](https://reader031.vdocuments.us/reader031/viewer/2022020413/5b5e59ca7f8b9a415d8c3a19/html5/thumbnails/6.jpg)
Contents
1.- Part 1
1.1.- Monitoring Objectives
1.2.- Special Monitoring Requirements
1.3.- Monitoring Results
1.4.- Operational Information
1.5.- Monitoring Deviations
1.6.- Monitoring Procedures and Deviations
2.- Part 2
Appendix 1: General Information
Appendix 2: Monitoring Information
Fitz Scientific
Derryfrench, Tynagh, Co Galway
Sperrin Galvanizers Limited
Visit No: 1Year: 2017
P0658-01Industrial Emissions LicenceP0658-01CAR17-01
3 of 33Site Visit Report - SV10472 - Sperrin Galvanisers (Ireland) Limited Page 6 of 37
![Page 7: Site Visit Report · 2017-12-12 · HCl Impinger efficiency is lower than the requirements of 95% total of concentration in the first impinger (BS EN 1911:2010 section 5.2.1.2.2)](https://reader031.vdocuments.us/reader031/viewer/2022020413/5b5e59ca7f8b9a415d8c3a19/html5/thumbnails/7.jpg)
Fitz Scientific
Derryfrench, Tynagh, Co Galway
Sperrin Galvanizers Limited
Visit No: 1Year: 2017
P0658-01Industrial Emissions LicenceP0658-01CAR17-01
1.- Part 1
1.1.- Monitoring Objectives
1.2.- Special Monitoring Remarks
All the sampling points were obtainable Yes
All parameters were sampled Yes
Opinions and interpretations expressed in this report are outside the scope of any claimed UKAS accreditation.EPA requirements AG1 (Safety) and AG2 (Monitoring Guidance Note) were applied during the monitoring.
Additional information
The monitoring was carried out at this installation as part of compliance monitoring of an Industrial Emissions Licence requirement. This Air Emissions Monitoring has been carried out by Fitz Scientific on behalf of the Environmental Protection Agency. The substances monitored at the emission points are listed below.
A1
Parameter Result
Cadmium - Cd 0.00083 mg/m3
Hydrogen Chloride <0.3 mg/m3
Lead - Pb 0.00493 mg/m3
Volumetric flow 11540.2 m3/h
Zinc - Zn 0.11558 mg/m3
4 of 33Site Visit Report - SV10472 - Sperrin Galvanisers (Ireland) Limited Page 7 of 37
![Page 8: Site Visit Report · 2017-12-12 · HCl Impinger efficiency is lower than the requirements of 95% total of concentration in the first impinger (BS EN 1911:2010 section 5.2.1.2.2)](https://reader031.vdocuments.us/reader031/viewer/2022020413/5b5e59ca7f8b9a415d8c3a19/html5/thumbnails/8.jpg)
Fitz Scientific
Derryfrench, Tynagh, Co Galway
Sperrin Galvanizers Limited
Visit No: 1Year: 2017
P0658-01Industrial Emissions LicenceP0658-01CAR17-01
1.3.- Monitoring Results
Analysis information
Emission Point
ReferenceSubstance to be Monitored ELV Result
Uncert (+/-) Units
Date of sampling
Start - End
Times Reference Method Accr.velocity
(m/s)LOD
A1 Cadmium - Cd 0.00083 n/a 26/07/2017 11:20-12:20
BS EN 14385:2004 MCERTS5.540.00040 mg/m30.05 mg/m3
A1 Hydrogen Chloride <0.3 0.1 26/07/2017 10:25-10:55
BS EN 1911:2010 MCERTS5.540.3 mg/m310 mg/m3
A1 Lead - Pb 0.00493 n/a 26/07/2017 11:20-12:20
BS EN 14385:2004 MCERTS5.540.00060 mg/m30.1 mg/m3
A1 Volumetric flow 11540.2 457.2 26/07/2017 11:10-11:15
BS EN 16911-1:2013 MCERTS5.54n/a m3/h15500 m3/h
A1 Zinc - Zn 0.11558 n/a 26/07/2017 11:20-12:20
BS EN 14385:2004 MCERTS5.540.10937 mg/m30.2 mg/m3
Cadmium - Cd RPS - Salford
Hydrogen Chloride Fitz Scientific
Lead - Pb RPS - Salford
Volumetric flow Fitz Scientific
Zinc - Zn RPS - Salford
Cadmium - Cd-blank
0.01432 n/a 26/07/2017 11:06-11:08
BS EN 14385:2004 MCERTS0.00040 mg/m3A1
Hydrogen Chloride-blank
<0.2 0.1 26/07/2017 10:10-10:12
BS EN 1911:2010 MCERTS0.3 mg/m3A1
Lead - Pb-blank 0.00061 n/a 26/07/2017 11:06-11:08
BS EN 14385:2004 MCERTS0.00060 mg/m3A1
Zinc - Zn-blank 0.01453 n/a 26/07/2017 11:06-11:08
BS EN 14385:2004 MCERTS0.10937 mg/m3A1
Sampling stage carried out as per MCERTS requirementsNo*:
5 of 33Site Visit Report - SV10472 - Sperrin Galvanisers (Ireland) Limited Page 8 of 37
![Page 9: Site Visit Report · 2017-12-12 · HCl Impinger efficiency is lower than the requirements of 95% total of concentration in the first impinger (BS EN 1911:2010 section 5.2.1.2.2)](https://reader031.vdocuments.us/reader031/viewer/2022020413/5b5e59ca7f8b9a415d8c3a19/html5/thumbnails/9.jpg)
Fitz Scientific
Derryfrench, Tynagh, Co Galway
Sperrin Galvanizers Limited
Visit No: 1Year: 2017
P0658-01Industrial Emissions LicenceP0658-01CAR17-01
Additional information
* The reported uncertainty is based on a standard uncertainty multiplied by a coverage factor k=2, providing a level of confidence of approximately 95%
** Results reported at following Reference Conditions
Reference Conditions
Abatement system and process load
Emission Point Reference Temperature (K) Pressure (KPa) Moisture (%) Oxygen (%)
Monitoring Result Reference Conditions
A1 273 101.3 no correctionno correction
Abatement system In Operation Fuel type and LoadLocation
Bag Filter Yes As NormalA1 None
6 of 33Site Visit Report - SV10472 - Sperrin Galvanisers (Ireland) Limited Page 9 of 37
![Page 10: Site Visit Report · 2017-12-12 · HCl Impinger efficiency is lower than the requirements of 95% total of concentration in the first impinger (BS EN 1911:2010 section 5.2.1.2.2)](https://reader031.vdocuments.us/reader031/viewer/2022020413/5b5e59ca7f8b9a415d8c3a19/html5/thumbnails/10.jpg)
Fitz Scientific
Derryfrench, Tynagh, Co Galway
Sperrin Galvanizers Limited
Visit No: 1Year: 2017
P0658-01Industrial Emissions LicenceP0658-01CAR17-01
1.4.- Operating Information
Emission Point Reference Date Process Type
ProcessDuration Substance CEMS PR Units
A1 26/07/2017 n/a 0.00083Cadmium - CdAir Extraction Continuous mg/m3
A1 26/07/2017 n/a <0.3Hydrogen ChlorideAir Extraction Continuous mg/m3
A1 26/07/2017 n/a 0.00493Lead - PbAir Extraction Continuous mg/m3
A1 26/07/2017 n/a 11540.2Volumetric flowAir Extraction Continuous m3/h
A1 26/07/2017 n/a 0.11558Zinc - ZnAir Extraction Continuous mg/m3
* CEMS: Continuous Emission Monitoring System Results
* PR: Periodic Monitoring Results
7 of 33Site Visit Report - SV10472 - Sperrin Galvanisers (Ireland) Limited Page 10 of 37
![Page 11: Site Visit Report · 2017-12-12 · HCl Impinger efficiency is lower than the requirements of 95% total of concentration in the first impinger (BS EN 1911:2010 section 5.2.1.2.2)](https://reader031.vdocuments.us/reader031/viewer/2022020413/5b5e59ca7f8b9a415d8c3a19/html5/thumbnails/11.jpg)
Fitz Scientific
Derryfrench, Tynagh, Co Galway
Sperrin Galvanizers Limited
Visit No: 1Year: 2017
P0658-01Industrial Emissions LicenceP0658-01CAR17-01
1.5.- Monitoring Deviations
Monitoring carried out as per Standard Methods. No deviations were recorded
Isokinetic conditions were outside the requirements of BS EN 13282-1 section 10.4.
Due to the high velocity in the duct a smaller nozzle size was used than required by BS EN 13282-1 section 5.2.4 (6mm) to carry out isokinetic sampling.
Emission monitoring point does not have required number of ports as per AG1 section 2.1/2.2 (per M1 Figure A2.5).
The ELV is such that the LOD for the analysis does not allow for the requirement of >10% ELV to be achieved (for ELV >5 mg/m3) (MID 13248-1 section 10.6)
The ELV is such that the LOD for the analysis does not allow for the requirement of >20% ELV to be achieved (for ELV <5 mg/m3) (MID 13248-1 section 10.6)
Negative flow was found (BS EN 13284-1 section 5.2 b).
The stack flow direction doesn’t meet the minimum requirement of 15 degrees with regard the axis of the stack. (BS EN 13284-1 section 5.2 a).
The ratio of highest to lowest local gas velocity is outside (higher than 3:1) of BS EN 13284-1 section 5.2 d) requirements.
Emission point does not meet the requirements of BS EN 15259:2007 Section 6.2.1 NOTE 4 and AG1 section 2.1/2.2 (per M1 Annex 1) - The measurement plane is not in a section of duct that is at least 5 hydraulic diameters of straight duct upstream of the sampling plane and 2 hydraulic diameters downtream (5 hydraulic diameters from the top of the stack)
Sampling port size is too small for velocity, temperature and pressure measurements to be carried out as per AG1 section 2.1/2.2 (M1 Annex 1).
Differential pressure lower than 5Pa measured with pitot tube (BS EN 13284-1 section 5.2 c).
SO2 Impinger efficiency is lower than the requirements of 95% total of concentration in the first impinger (BS EN 14791:2017 section 6.6.1)
NOx calibration drift is higher than 2% of the span value. Results are corrected to drift. (TGN M22 Section 6)
The blank reading does not meet the required target of <10% of the daily limit value (for ELV >10 mg/m3) (BS EN 12384-1 section 10.6)
A1Emission Point Cadmium - CdParameter
NOx overall uncertainty calculated is outside requirement of <10% at the daily ELV, or the lowest limit value assigned by the local authorities, expressed on dry basis before correction to O2 reference concentration as per Section 8 BS EN 14789:2017
CO overall uncertainty calculated is outside requirement of <6% at the daily ELV expressed on dry basis before correction to O2 reference concentration as per 7.3 BS EN 15058:2017.
O2 overall uncertainty calculated is outside requirement of <6% of the value expressed on dry basis, or 0.3% expressed as a volume concentration as per Section 8 BS EN 14789:2017
CO calibration drift is higher than 2% of the span value. Results are corrected to drift. (TGN M22 Section 6)
O2 calibration drift is higher than 2% of the span value. Results are corrected to drift. (EN 14789:2017 Section 9.4.2.3)
TVOC calibration drift is higher than 2% of the span value. Results are corrected to drift. (BS EN 12619:2013 Section 6.2.3)
HCl Impinger efficiency is lower than the requirements of 95% total of concentration in the first impinger (BS EN 1911:2010 section 5.2.1.2.2)
HF Impinger efficiency is lower than the requirements of 95% total of concentration in the first impinger (BS ISO 15713:2006 section 6.4).
Homogeneity test is required for this stack as per BS EN 15259:2007 but customer did not require it in the Confirmation Form
The measurement values are invalid as the corresponding blank result is greater than the requirement identified in CEN/TS 13649:2014 section 10 (c) (must be <10% of the limit values)
8 of 33Site Visit Report - SV10472 - Sperrin Galvanisers (Ireland) Limited Page 11 of 37
![Page 12: Site Visit Report · 2017-12-12 · HCl Impinger efficiency is lower than the requirements of 95% total of concentration in the first impinger (BS EN 1911:2010 section 5.2.1.2.2)](https://reader031.vdocuments.us/reader031/viewer/2022020413/5b5e59ca7f8b9a415d8c3a19/html5/thumbnails/12.jpg)
Fitz Scientific
Derryfrench, Tynagh, Co Galway
Sperrin Galvanizers Limited
Visit No: 1Year: 2017
P0658-01Industrial Emissions LicenceP0658-01CAR17-01
Low HCl levels detected. Impinger efficiency NOT relevent
Isokinetic conditions were outside the requirements of BS EN 13282-1 section 10.4.
Due to the high velocity in the duct a smaller nozzle size was used than required by BS EN 13282-1 section 5.2.4 (6mm) to carry out isokinetic sampling.
Emission monitoring point does not have required number of ports as per AG1 section 2.1/2.2 (per M1 Figure A2.5).
The ELV is such that the LOD for the analysis does not allow for the requirement of >10% ELV to be achieved (for ELV >5 mg/m3) (MID 13248-1 section 10.6)
The ELV is such that the LOD for the analysis does not allow for the requirement of >20% ELV to be achieved (for ELV <5 mg/m3) (MID 13248-1 section 10.6)
Negative flow was found (BS EN 13284-1 section 5.2 b).
The stack flow direction doesn’t meet the minimum requirement of 15 degrees with regard the axis of the stack. (BS EN 13284-1 section 5.2 a).
The ratio of highest to lowest local gas velocity is outside (higher than 3:1) of BS EN 13284-1 section 5.2 d) requirements.
Emission point does not meet the requirements of BS EN 15259:2007 Section 6.2.1 NOTE 4 and AG1 section 2.1/2.2 (per M1 Annex 1) - The measurement plane is not in a section of duct that is at least 5 hydraulic diameters of straight duct upstream of the sampling plane and 2 hydraulic diameters downtream (5 hydraulic diameters from the top of the stack)
Sampling port size is too small for velocity, temperature and pressure measurements to be carried out as per AG1 section 2.1/2.2 (M1 Annex 1).
Differential pressure lower than 5Pa measured with pitot tube (BS EN 13284-1 section 5.2 c).
SO2 Impinger efficiency is lower than the requirements of 95% total of concentration in the first impinger (BS EN 14791:2017 section 6.6.1)
NOx calibration drift is higher than 2% of the span value. Results are corrected to drift. (TGN M22 Section 6)
The blank reading does not meet the required target of <10% of the daily limit value (for ELV >10 mg/m3) (BS EN 12384-1 section 10.6)
A1Emission Point Hydrogen ChlorideParameter
NOx overall uncertainty calculated is outside requirement of <10% at the daily ELV, or the lowest limit value assigned by the local authorities, expressed on dry basis before correction to O2 reference concentration as per Section 8 BS EN 14789:2017
CO overall uncertainty calculated is outside requirement of <6% at the daily ELV expressed on dry basis before correction to O2 reference concentration as per 7.3 BS EN 15058:2017.
O2 overall uncertainty calculated is outside requirement of <6% of the value expressed on dry basis, or 0.3% expressed as a volume concentration as per Section 8 BS EN 14789:2017
CO calibration drift is higher than 2% of the span value. Results are corrected to drift. (TGN M22 Section 6)
O2 calibration drift is higher than 2% of the span value. Results are corrected to drift. (EN 14789:2017 Section 9.4.2.3)
TVOC calibration drift is higher than 2% of the span value. Results are corrected to drift. (BS EN 12619:2013 Section 6.2.3)
HCl Impinger efficiency is lower than the requirements of 95% total of concentration in the first impinger (BS EN 1911:2010 section 5.2.1.2.2)
HF Impinger efficiency is lower than the requirements of 95% total of concentration in the first impinger (BS ISO 15713:2006 section 6.4).
Homogeneity test is required for this stack as per BS EN 15259:2007 but customer did not require it in the Confirmation Form
The measurement values are invalid as the corresponding blank result is greater than the requirement identified in CEN/TS 13649:2014 section 10 (c) (must be <10% of the limit values)
9 of 33Site Visit Report - SV10472 - Sperrin Galvanisers (Ireland) Limited Page 12 of 37
![Page 13: Site Visit Report · 2017-12-12 · HCl Impinger efficiency is lower than the requirements of 95% total of concentration in the first impinger (BS EN 1911:2010 section 5.2.1.2.2)](https://reader031.vdocuments.us/reader031/viewer/2022020413/5b5e59ca7f8b9a415d8c3a19/html5/thumbnails/13.jpg)
Fitz Scientific
Derryfrench, Tynagh, Co Galway
Sperrin Galvanizers Limited
Visit No: 1Year: 2017
P0658-01Industrial Emissions LicenceP0658-01CAR17-01
Monitoring carried out as per Standard Methods. No deviations were recorded
Isokinetic conditions were outside the requirements of BS EN 13282-1 section 10.4.
Due to the high velocity in the duct a smaller nozzle size was used than required by BS EN 13282-1 section 5.2.4 (6mm) to carry out isokinetic sampling.
Emission monitoring point does not have required number of ports as per AG1 section 2.1/2.2 (per M1 Figure A2.5).
The ELV is such that the LOD for the analysis does not allow for the requirement of >10% ELV to be achieved (for ELV >5 mg/m3) (MID 13248-1 section 10.6)
The ELV is such that the LOD for the analysis does not allow for the requirement of >20% ELV to be achieved (for ELV <5 mg/m3) (MID 13248-1 section 10.6)
Negative flow was found (BS EN 13284-1 section 5.2 b).
The stack flow direction doesn’t meet the minimum requirement of 15 degrees with regard the axis of the stack. (BS EN 13284-1 section 5.2 a).
The ratio of highest to lowest local gas velocity is outside (higher than 3:1) of BS EN 13284-1 section 5.2 d) requirements.
Emission point does not meet the requirements of BS EN 15259:2007 Section 6.2.1 NOTE 4 and AG1 section 2.1/2.2 (per M1 Annex 1) - The measurement plane is not in a section of duct that is at least 5 hydraulic diameters of straight duct upstream of the sampling plane and 2 hydraulic diameters downtream (5 hydraulic diameters from the top of the stack)
Sampling port size is too small for velocity, temperature and pressure measurements to be carried out as per AG1 section 2.1/2.2 (M1 Annex 1).
Differential pressure lower than 5Pa measured with pitot tube (BS EN 13284-1 section 5.2 c).
SO2 Impinger efficiency is lower than the requirements of 95% total of concentration in the first impinger (BS EN 14791:2017 section 6.6.1)
NOx calibration drift is higher than 2% of the span value. Results are corrected to drift. (TGN M22 Section 6)
The blank reading does not meet the required target of <10% of the daily limit value (for ELV >10 mg/m3) (BS EN 12384-1 section 10.6)
A1Emission Point Lead - PbParameter
NOx overall uncertainty calculated is outside requirement of <10% at the daily ELV, or the lowest limit value assigned by the local authorities, expressed on dry basis before correction to O2 reference concentration as per Section 8 BS EN 14789:2017
CO overall uncertainty calculated is outside requirement of <6% at the daily ELV expressed on dry basis before correction to O2 reference concentration as per 7.3 BS EN 15058:2017.
O2 overall uncertainty calculated is outside requirement of <6% of the value expressed on dry basis, or 0.3% expressed as a volume concentration as per Section 8 BS EN 14789:2017
CO calibration drift is higher than 2% of the span value. Results are corrected to drift. (TGN M22 Section 6)
O2 calibration drift is higher than 2% of the span value. Results are corrected to drift. (EN 14789:2017 Section 9.4.2.3)
TVOC calibration drift is higher than 2% of the span value. Results are corrected to drift. (BS EN 12619:2013 Section 6.2.3)
HCl Impinger efficiency is lower than the requirements of 95% total of concentration in the first impinger (BS EN 1911:2010 section 5.2.1.2.2)
HF Impinger efficiency is lower than the requirements of 95% total of concentration in the first impinger (BS ISO 15713:2006 section 6.4).
Homogeneity test is required for this stack as per BS EN 15259:2007 but customer did not require it in the Confirmation Form
The measurement values are invalid as the corresponding blank result is greater than the requirement identified in CEN/TS 13649:2014 section 10 (c) (must be <10% of the limit values)
10 of 33Site Visit Report - SV10472 - Sperrin Galvanisers (Ireland) Limited Page 13 of 37
![Page 14: Site Visit Report · 2017-12-12 · HCl Impinger efficiency is lower than the requirements of 95% total of concentration in the first impinger (BS EN 1911:2010 section 5.2.1.2.2)](https://reader031.vdocuments.us/reader031/viewer/2022020413/5b5e59ca7f8b9a415d8c3a19/html5/thumbnails/14.jpg)
Fitz Scientific
Derryfrench, Tynagh, Co Galway
Sperrin Galvanizers Limited
Visit No: 1Year: 2017
P0658-01Industrial Emissions LicenceP0658-01CAR17-01
Isokinetic conditions were outside the requirements of BS EN 13282-1 section 10.4.
Due to the high velocity in the duct a smaller nozzle size was used than required by BS EN 13282-1 section 5.2.4 (6mm) to carry out isokinetic sampling.
Emission monitoring point does not have required number of ports as per AG1 section 2.1/2.2 (per M1 Figure A2.5).
The ELV is such that the LOD for the analysis does not allow for the requirement of >10% ELV to be achieved (for ELV >5 mg/m3) (MID 13248-1 section 10.6)
The ELV is such that the LOD for the analysis does not allow for the requirement of >20% ELV to be achieved (for ELV <5 mg/m3) (MID 13248-1 section 10.6)
Negative flow was found (BS EN 13284-1 section 5.2 b).
The stack flow direction doesn’t meet the minimum requirement of 15 degrees with regard the axis of the stack. (BS EN 13284-1 section 5.2 a).
The ratio of highest to lowest local gas velocity is outside (higher than 3:1) of BS EN 13284-1 section 5.2 d) requirements.
Emission point does not meet the requirements of BS EN 15259:2007 Section 6.2.1 NOTE 4 and AG1 section 2.1/2.2 (per M1 Annex 1) - The measurement plane is not in a section of duct that is at least 5 hydraulic diameters of straight duct upstream of the sampling plane and 2 hydraulic diameters downtream (5 hydraulic diameters from the top of the stack)
Sampling port size is too small for velocity, temperature and pressure measurements to be carried out as per AG1 section 2.1/2.2 (M1 Annex 1).
Differential pressure lower than 5Pa measured with pitot tube (BS EN 13284-1 section 5.2 c).
SO2 Impinger efficiency is lower than the requirements of 95% total of concentration in the first impinger (BS EN 14791:2017 section 6.6.1)
NOx calibration drift is higher than 2% of the span value. Results are corrected to drift. (TGN M22 Section 6)
The blank reading does not meet the required target of <10% of the daily limit value (for ELV >10 mg/m3) (BS EN 12384-1 section 10.6)
A1Emission Point Volumetric flowParameter
NOx overall uncertainty calculated is outside requirement of <10% at the daily ELV, or the lowest limit value assigned by the local authorities, expressed on dry basis before correction to O2 reference concentration as per Section 8 BS EN 14789:2017
CO overall uncertainty calculated is outside requirement of <6% at the daily ELV expressed on dry basis before correction to O2 reference concentration as per 7.3 BS EN 15058:2017.
O2 overall uncertainty calculated is outside requirement of <6% of the value expressed on dry basis, or 0.3% expressed as a volume concentration as per Section 8 BS EN 14789:2017
CO calibration drift is higher than 2% of the span value. Results are corrected to drift. (TGN M22 Section 6)
O2 calibration drift is higher than 2% of the span value. Results are corrected to drift. (EN 14789:2017 Section 9.4.2.3)
TVOC calibration drift is higher than 2% of the span value. Results are corrected to drift. (BS EN 12619:2013 Section 6.2.3)
HCl Impinger efficiency is lower than the requirements of 95% total of concentration in the first impinger (BS EN 1911:2010 section 5.2.1.2.2)
HF Impinger efficiency is lower than the requirements of 95% total of concentration in the first impinger (BS ISO 15713:2006 section 6.4).
Homogeneity test is required for this stack as per BS EN 15259:2007 but customer did not require it in the Confirmation Form
The measurement values are invalid as the corresponding blank result is greater than the requirement identified in CEN/TS 13649:2014 section 10 (c) (must be <10% of the limit values)
11 of 33Site Visit Report - SV10472 - Sperrin Galvanisers (Ireland) Limited Page 14 of 37
![Page 15: Site Visit Report · 2017-12-12 · HCl Impinger efficiency is lower than the requirements of 95% total of concentration in the first impinger (BS EN 1911:2010 section 5.2.1.2.2)](https://reader031.vdocuments.us/reader031/viewer/2022020413/5b5e59ca7f8b9a415d8c3a19/html5/thumbnails/15.jpg)
Fitz Scientific
Derryfrench, Tynagh, Co Galway
Sperrin Galvanizers Limited
Visit No: 1Year: 2017
P0658-01Industrial Emissions LicenceP0658-01CAR17-01
Monitoring carried out as per Standard Methods. No deviations were recorded
Isokinetic conditions were outside the requirements of BS EN 13282-1 section 10.4.
Due to the high velocity in the duct a smaller nozzle size was used than required by BS EN 13282-1 section 5.2.4 (6mm) to carry out isokinetic sampling.
Emission monitoring point does not have required number of ports as per AG1 section 2.1/2.2 (per M1 Figure A2.5).
The ELV is such that the LOD for the analysis does not allow for the requirement of >10% ELV to be achieved (for ELV >5 mg/m3) (MID 13248-1 section 10.6)
The ELV is such that the LOD for the analysis does not allow for the requirement of >20% ELV to be achieved (for ELV <5 mg/m3) (MID 13248-1 section 10.6)
Negative flow was found (BS EN 13284-1 section 5.2 b).
The stack flow direction doesn’t meet the minimum requirement of 15 degrees with regard the axis of the stack. (BS EN 13284-1 section 5.2 a).
The ratio of highest to lowest local gas velocity is outside (higher than 3:1) of BS EN 13284-1 section 5.2 d) requirements.
Emission point does not meet the requirements of BS EN 15259:2007 Section 6.2.1 NOTE 4 and AG1 section 2.1/2.2 (per M1 Annex 1) - The measurement plane is not in a section of duct that is at least 5 hydraulic diameters of straight duct upstream of the sampling plane and 2 hydraulic diameters downtream (5 hydraulic diameters from the top of the stack)
Sampling port size is too small for velocity, temperature and pressure measurements to be carried out as per AG1 section 2.1/2.2 (M1 Annex 1).
Differential pressure lower than 5Pa measured with pitot tube (BS EN 13284-1 section 5.2 c).
SO2 Impinger efficiency is lower than the requirements of 95% total of concentration in the first impinger (BS EN 14791:2017 section 6.6.1)
NOx calibration drift is higher than 2% of the span value. Results are corrected to drift. (TGN M22 Section 6)
The blank reading does not meet the required target of <10% of the daily limit value (for ELV >10 mg/m3) (BS EN 12384-1 section 10.6)
A1Emission Point Zinc - ZnParameter
NOx overall uncertainty calculated is outside requirement of <10% at the daily ELV, or the lowest limit value assigned by the local authorities, expressed on dry basis before correction to O2 reference concentration as per Section 8 BS EN 14789:2017
CO overall uncertainty calculated is outside requirement of <6% at the daily ELV expressed on dry basis before correction to O2 reference concentration as per 7.3 BS EN 15058:2017.
O2 overall uncertainty calculated is outside requirement of <6% of the value expressed on dry basis, or 0.3% expressed as a volume concentration as per Section 8 BS EN 14789:2017
CO calibration drift is higher than 2% of the span value. Results are corrected to drift. (TGN M22 Section 6)
O2 calibration drift is higher than 2% of the span value. Results are corrected to drift. (EN 14789:2017 Section 9.4.2.3)
TVOC calibration drift is higher than 2% of the span value. Results are corrected to drift. (BS EN 12619:2013 Section 6.2.3)
HCl Impinger efficiency is lower than the requirements of 95% total of concentration in the first impinger (BS EN 1911:2010 section 5.2.1.2.2)
HF Impinger efficiency is lower than the requirements of 95% total of concentration in the first impinger (BS ISO 15713:2006 section 6.4).
Homogeneity test is required for this stack as per BS EN 15259:2007 but customer did not require it in the Confirmation Form
The measurement values are invalid as the corresponding blank result is greater than the requirement identified in CEN/TS 13649:2014 section 10 (c) (must be <10% of the limit values)
12 of 33Site Visit Report - SV10472 - Sperrin Galvanisers (Ireland) Limited Page 15 of 37
![Page 16: Site Visit Report · 2017-12-12 · HCl Impinger efficiency is lower than the requirements of 95% total of concentration in the first impinger (BS EN 1911:2010 section 5.2.1.2.2)](https://reader031.vdocuments.us/reader031/viewer/2022020413/5b5e59ca7f8b9a415d8c3a19/html5/thumbnails/16.jpg)
Fitz Scientific
Derryfrench, Tynagh, Co Galway
Sperrin Galvanizers Limited
Visit No: 1Year: 2017
P0658-01Industrial Emissions LicenceP0658-01CAR17-01
Licence / Permit Number:
Job Quote Number:
P0658-01
EPA17060
Operator Name:
Installation:
Phone:
Contact Name:
Sperrin Galvanizers Limited
Derryfrench, Tynagh, Co Galway
John Moore O’Connor
0909745804
Monitoring Dates:
Monitoring Organisation: Fitz Scientific
Unit 35, Boyne Business Park, Drogheda, Co. Louth, Ireland
Phone: +353 41 98 45440 / Fax: +353 41 98 46171
email: [email protected]
2.- Part 2
Supporting information
26/07/2017
Laboratory details
Cadmium - Cd
Address Contact email Phone Acc. Number
Unit 12, Waters Edge Business Park, Modwen Road, Salford, M5 3EZ, UK
Paul Chesney
+44 (0)161 877 3959
UKAS 0605RPS - Salford
Hydrogen Chloride
Address Contact email Phone Acc. Number
Unit 35, Boyne Business Park, Drogheda, Co. Louth, Ireland
Geoff Fitzpatrick
[email protected] +353 41 98 45440 - ext 2
UKAS 2802Fitz Scientific
Lead - Pb
Address Contact email Phone Acc. Number
Unit 12, Waters Edge Business Park, Modwen Road, Salford, M5 3EZ, UK
Paul Chesney
+44 (0)161 877 3959
UKAS 0605RPS - Salford
Volumetric flow
Address Contact email Phone Acc. Number
13 of 33Site Visit Report - SV10472 - Sperrin Galvanisers (Ireland) Limited Page 16 of 37
![Page 17: Site Visit Report · 2017-12-12 · HCl Impinger efficiency is lower than the requirements of 95% total of concentration in the first impinger (BS EN 1911:2010 section 5.2.1.2.2)](https://reader031.vdocuments.us/reader031/viewer/2022020413/5b5e59ca7f8b9a415d8c3a19/html5/thumbnails/17.jpg)
Fitz Scientific
Derryfrench, Tynagh, Co Galway
Sperrin Galvanizers Limited
Visit No: 1Year: 2017
P0658-01Industrial Emissions LicenceP0658-01CAR17-01
Unit 35, Boyne Business Park, Drogheda, Co. Louth, Ireland
Geoff Fitzpatrick
[email protected] +353 41 98 45440 - ext 2
UKAS 2802Fitz Scientific
Zinc - Zn
Address Contact email Phone Acc. Number
Unit 12, Waters Edge Business Park, Modwen Road, Salford, M5 3EZ, UK
Paul Chesney
+44 (0)161 877 3959
UKAS 0605RPS - Salford
14 of 33Site Visit Report - SV10472 - Sperrin Galvanisers (Ireland) Limited Page 17 of 37
![Page 18: Site Visit Report · 2017-12-12 · HCl Impinger efficiency is lower than the requirements of 95% total of concentration in the first impinger (BS EN 1911:2010 section 5.2.1.2.2)](https://reader031.vdocuments.us/reader031/viewer/2022020413/5b5e59ca7f8b9a415d8c3a19/html5/thumbnails/18.jpg)
Fitz Scientific
Derryfrench, Tynagh, Co Galway
Sperrin Galvanizers Limited
Visit No: 1Year: 2017
P0658-01Industrial Emissions LicenceP0658-01CAR17-01
Appendix 1:
Sampling personnel used
Substances Monitored
Equipment Checklist References
As an accredited organisation Fitz scientific have implemented procedures to ensure that the requirements of TPS 63 (UKAS Policy on Deviating Samples) are met with regard to samples taken and tested for chemical analysis. As such all samples, when applicable, have been transported in containers, and in an environment, that meet the relevant standard requirements where applicable
Substance Fitz SOPMethod used for Monitoring
Cadmium - Cd BS EN 14385:2004 113
Hydrogen Chloride BS EN 1911:2010 148
Lead - Pb BS EN 14385:2004 113
Volumetric flow BS EN 16911-1:2013 122
Zinc - Zn BS EN 14385:2004 113
Stack: A1
EM402
Set1
Set C
Probe1
EM372
EM201 (a
EM389 EM3273/EM3277
n/a
n/a
n/a
n/a n/a
n/a
n/a
TCR
Nozzles
Impingers
Probe
Pitot tube
Weights
Caliper Filters
Horiba
FID
FTIR
Testo Gases
Handheld pumps
Tubes
Zinc - ZnParameter:
EM402
n/a
n/a
Probe1
EM372
n/a
n/a n/a
n/a
n/a
n/a
n/a n/a
n/a
n/a
TCR
Nozzles
Impingers
Probe
Pitot tube
Weights
Caliper Filters
Horiba
FID
FTIR
Testo Gases
Handheld pumps
Tubes
Volumetric flowParameter:
EM402
Set1
Set C
Probe1
EM372
EM201 (a
EM389 EM3273/EM3277
n/a
n/a
n/a
n/a n/a
n/a
n/a
TCR
Nozzles
Impingers
Probe
Pitot tube
Weights
Caliper Filters
Horiba
FID
FTIR
Testo Gases
Handheld pumps
Tubes
Lead - PbParameter:
26/07/2017 Technician Name Position Qualification TEs MCERTS no
Aadil Khan Team Leader Level 2 TE1, TE2, TE3, TE4
Jason McGuirk Team Leader Level 2 TE1, TE2, TE3, TE4
MM11 1120
MM14 1320
15 of 33Site Visit Report - SV10472 - Sperrin Galvanisers (Ireland) Limited Page 18 of 37
![Page 19: Site Visit Report · 2017-12-12 · HCl Impinger efficiency is lower than the requirements of 95% total of concentration in the first impinger (BS EN 1911:2010 section 5.2.1.2.2)](https://reader031.vdocuments.us/reader031/viewer/2022020413/5b5e59ca7f8b9a415d8c3a19/html5/thumbnails/19.jpg)
Fitz Scientific
Derryfrench, Tynagh, Co Galway
Sperrin Galvanizers Limited
Visit No: 1Year: 2017
P0658-01Industrial Emissions LicenceP0658-01CAR17-01
EM402
n/a
Set A
Probe1
n/a
EM201 (a
n/a n/a
n/a
n/a
n/a
n/a n/a
n/a
n/a
TCR
Nozzles
Impingers
Probe
Pitot tube
Weights
Caliper Filters
Horiba
FID
FTIR
Testo Gases
Handheld pumps
Tubes
Hydrogen ChlorideParameter:
EM402
Set1
Set C
Probe1
EM372
EM201 (a
EM389 EM3273/EM3277
n/a
n/a
n/a
n/a n/a
n/a
n/a
TCR
Nozzles
Impingers
Probe
Pitot tube
Weights
Caliper Filters
Horiba
FID
FTIR
Testo Gases
Handheld pumps
Tubes
Cadmium - CdParameter:
16 of 33Site Visit Report - SV10472 - Sperrin Galvanisers (Ireland) Limited Page 19 of 37
![Page 20: Site Visit Report · 2017-12-12 · HCl Impinger efficiency is lower than the requirements of 95% total of concentration in the first impinger (BS EN 1911:2010 section 5.2.1.2.2)](https://reader031.vdocuments.us/reader031/viewer/2022020413/5b5e59ca7f8b9a415d8c3a19/html5/thumbnails/20.jpg)
Fitz Scientific
Derryfrench, Tynagh, Co Galway
Sperrin Galvanizers Limited
Visit No: 1Year: 2017
P0658-01Industrial Emissions LicenceP0658-01CAR17-01
Appendix 2:
Monitoring Information
2
4
5.54
99.462
34.68
0.92
13246.5
11540.2
11540.2
273
101.3
n/a
n/a
n/a
Number of Ports
Number of Points
Average Velocity v'a (m/s)
Average Pressure (KPa)
Average Temperature (ºC)
Stack Diameter (m)
Actual Moisture Flow rate (m3/h)
Moisture Flow rate at STP (m3/h)
Dry Flow rate at STP, Ref O2 (m3/h)
T reference (Deg K)
P reference (KPa)
Isokinetic condition (%)
Oxygen measured (%)
Water vapor (%)
Wet Stack (yes/no) No
Probe Temperature (°C) n/a
Impinger efficiency (%) HCl(42.75)
Size of Nozzle 7
A1Stack Parameter: Volumetric Flow, HCl, Cd, Pb, Zn
Max Flow Rate in Licence (m3/h): 15500
17 of 33Site Visit Report - SV10472 - Sperrin Galvanisers (Ireland) Limited Page 20 of 37
![Page 21: Site Visit Report · 2017-12-12 · HCl Impinger efficiency is lower than the requirements of 95% total of concentration in the first impinger (BS EN 1911:2010 section 5.2.1.2.2)](https://reader031.vdocuments.us/reader031/viewer/2022020413/5b5e59ca7f8b9a415d8c3a19/html5/thumbnails/21.jpg)
Fitz Scientific
Derryfrench, Tynagh, Co Galway
Sperrin Galvanizers Limited
Visit No: 1Year: 2017
P0658-01Industrial Emissions LicenceP0658-01CAR17-01
Diagram of Sampling Location (not to scale)
X
X
X
X X X
X
X
A
B
A1Circular
2
4
ports
points
Point % of Diameter Location (cm) Velocity (m/s) Temperature (ºC)
Traverse Length 0.92 m
Line
1 6.70 6.2 8.43 33.951
2 25.00 23 8.54 34.451
3 75.00 69 8.495 34.81
4 93.40 85.9 8.47 34.981
1 6.70 6.2 8.795 35.1292
2 25.00 23 8.59 35.262
3 75.00 69 8.42 35.2152
4 93.40 85.9 8.05 34.682
18 of 33Site Visit Report - SV10472 - Sperrin Galvanisers (Ireland) Limited Page 21 of 37
![Page 22: Site Visit Report · 2017-12-12 · HCl Impinger efficiency is lower than the requirements of 95% total of concentration in the first impinger (BS EN 1911:2010 section 5.2.1.2.2)](https://reader031.vdocuments.us/reader031/viewer/2022020413/5b5e59ca7f8b9a415d8c3a19/html5/thumbnails/22.jpg)
Fitz Scientific
Derryfrench, Tynagh, Co Galway
Sperrin Galvanizers Limited
Visit No: 1Year: 2017
P0658-01Industrial Emissions LicenceP0658-01CAR17-01
Monitoring result calculations and uncertainty calculations
19 of 33Site Visit Report - SV10472 - Sperrin Galvanisers (Ireland) Limited Page 22 of 37
![Page 23: Site Visit Report · 2017-12-12 · HCl Impinger efficiency is lower than the requirements of 95% total of concentration in the first impinger (BS EN 1911:2010 section 5.2.1.2.2)](https://reader031.vdocuments.us/reader031/viewer/2022020413/5b5e59ca7f8b9a415d8c3a19/html5/thumbnails/23.jpg)
Fitz ScientificP0658-01CAR17-01Yar: 2017 Visit no: 1________________________________________________________________________________________________________________________
Sperrin Galvanizers LimitedIndustrial Emissions Licence P0658-01
Volumetric Flowrate Correction Template BS EN 16911-1:2013Company Sperrin Galvanizers Limited Date of Test 26/07/2017Site Derryfrench, Tynagh, Co Galway Reference No P0658-01Plant Identification A1 Operator Id MM11 1120Test carried out by Aadil Khan TE's TE1, TE2, TE3, TE4
P0658-01CAR17-01
Stack information:
Stack dimensions
m Stack Area m2 No ports / No pointsSuitable ports
(Y/N)?
Comply with 5 Up / 2 Down?
(Y/N) Pressure kPa Temperature K Moisture % Oxygen %
Circular Stack 0.92 0.664761005 2 Yes NoReference Condition 101.3 273 0 20.9
Rectangular stack 0.00 0.00 0.00 4Stack Conditions 99.5 307.7 0.0 20.90
Actual Value: 0.664761005
PointVelocity m/s (v'a)
Temp degC (ta) Temp K Presssure kPa (Pa)
Flow Rate m3/sec:
Actual Flow rate m3/hr
Moisture Flow rate at STP m3/hr Moisture
Flow rate at STP, Dry m3/hr O2 %
Flow Rate at STP, Dry, Ref O2 m3/hr
1 5.54 34.6775 307.6775 99 3.7 13246.5 11540.2 0.0 11540.2 20.90 11540.2Volumetric flow 5.54 34.68 307.68 99.462 3.7 13246.5 11540.2 0.0 11540.2 20.90 11540.2Uncertainty 34.68 307.68 99.462 524.8 457.2 0.0 457.2 20.90 457.2
Maximum volumetric flow as per Licence 15500.0 m3/h
Report Number :
Calculation spreadsheet v.48 20 of 33
Site Visit Report - SV10472 - Sperrin Galvanisers (Ireland) Limited Page 23 of 37
![Page 24: Site Visit Report · 2017-12-12 · HCl Impinger efficiency is lower than the requirements of 95% total of concentration in the first impinger (BS EN 1911:2010 section 5.2.1.2.2)](https://reader031.vdocuments.us/reader031/viewer/2022020413/5b5e59ca7f8b9a415d8c3a19/html5/thumbnails/24.jpg)
Fitz ScientificP0658-01CAR17-01Yar: 2017 Visit no: 1_________________________________________________________________________________________________________________________
Sperrin Galvanizers LimitedIndustrial Emissions Licence P0658-01
v1.4 Oct-16Enter data in orange cells onlyConstantsGas constant 8.314 J/(K.mol)
1990 Pa0.01 Pa
2 % of value0.2 % of range between calibrations
PITOT 0.04 % of rangeSampling probe: Probe1 0.46 Pa
Pitot EM372 Water vapour me 0.00 % relativePitot coefficient, K 0.847 0.61 °C CO content meas 0.00 % relativeExpanded uncertainty (95%, k=2) 0.02 997.5 Pa CO2 content mea 0.00 % relative
0.50 % O2 content measu 0.00 % relative
Duct dimensions Circular RectangularDiameter 0.92 m a mArea 0.7 m2 b m
Area 0.00 m2Uncertainty (%) 0.501086957 Uncertainty (%) 0.00116889
All Pressures should be entered in Pascals, Pa
Measurement Point Atmospheric Pressure, PaStack Pressure, Pa Static Pressure, Pa meas1, Pa meas2, Pa meas3, Pa meas4, Pa meas5, Pa Delta P, Pa Stack Temperature, C
Water Vapour Content, % CO, ppm CO2, % N2, % O2, % dry molecular wt, g/mol stack molecular wt, g/mol
1 99450 99467 39.120 39.12 34.28 0.00 0.00 0 79.1 20.90 28.84 28.842 99450 99456 12.47 12.47 35.07 0.00 0.00 0 79.1 20.90 28.84 28.843 0.00 0.00 0 79.1 20.90 28.84 28.844 0.00 0.00 0 79.1 20.90 28.84 28.845 0.00 0.00 0 79.1 20.90 28.84 28.846 0.00 0.00 0 79.1 20.90 28.84 28.847 0.00 0.00 0 79.1 20.90 28.84 28.848 0.00 0.00 0 79.1 20.90 28.84 28.849 0.00 0.00 0 79.1 20.90 28.84 28.84
10 0.00 0.00 0 79.1 20.90 28.84 28.8411 0.00 0.00 0 79.1 20.90 28.84 28.8412 0.00 0.00 0 79.1 20.90 28.84 28.8413 0.00 0.00 0 79.1 20.90 28.84 28.8414 0.00 0.00 0 79.1 20.90 28.84 28.8415 0.00 0.00 0 79.1 20.90 28.84 28.8416 0.00 0.00 0 79.1 20.90 28.84 28.8417 0.00 0.00 0 79.1 20.90 28.84 28.8418 0.00 0.00 0 79.1 20.90 28.84 28.8419 0.00 0.00 0 79.1 20.90 28.84 28.8420 0.00 0.00 0 79.1 20.90 28.84 28.84
Mean 99450 99462 #DIV/0! 25.80 #DIV/0! #DIV/0! #DIV/0! #DIV/0! 25.80 34.68 0.00 0.0 0.0 79.1 20.9 28.84 28.84
Circular duct Rectangular ductMean velocity 5.54 m/sec Flow rate (stack conditions) 13246 m3/hour 0 m3/hour
Standard uncerta 0.10 m/sec 1.9 % of value Vol. flow rate expanded uncertain 525 m3/hour #DIV/0! m3/hour
Mean density 1.121 kg/m3 Expanded uncert 0.21 m/sec 3.8 % of value Vol. flow rate expanded uncertain 4.0 % of value #DIV/0! % of value
Developed for the STA by David Butterfield & Chris Dimopoulos, NPL
Uncertainty in duct area measurement
Dry gas basis
Uncertainty in stack gas compositionUncertainty in Delta P transducer Enter uncertainties as (95%,k=2) where relevant
Uncertainty in temperature readout systemUncertainty in atmospheric pressure transducer
Enter uncertainties as (95%,k=2) where relevant
Repeatability of Delta P transducerDrift of Delta P transducerLack of fit of measurement system
Uncertainty calculation for Velocity and Volume Flow Rate Measurement by Pitot tube EN ISO 16911‐1
Characteristics of pressure sensor used for Delta PEnter uncertainties as (95%,k=2) where relevant
Range of Delta P transducerResolution of Delta P transducer
Calculation spreadsheet v.48
21 of 33
Site Visit Report - SV10472 - Sperrin Galvanisers (Ireland) Limited Page 24 of 37
![Page 25: Site Visit Report · 2017-12-12 · HCl Impinger efficiency is lower than the requirements of 95% total of concentration in the first impinger (BS EN 1911:2010 section 5.2.1.2.2)](https://reader031.vdocuments.us/reader031/viewer/2022020413/5b5e59ca7f8b9a415d8c3a19/html5/thumbnails/25.jpg)
Fitz ScientificP0658-01CAR17-01Yar: 2017 Visit no: 1_______________________________________________________________________________________________________________________
Sperrin Galvanizers LimitedIndustrial Emissions Licence P0658-01
Velocity associated uncertainties
Pitot Tube CoefficientExpanded uncertainty (95%, k=2) 0.02Standard uncertainty (Dimensionless) 0.01
Table 1
Delta P Standard uncertanites^2 Measurement Point SD of the mean of the DP measurements (Standard uncertainty Delta P)^2 u2(Dpi)Velocity (m/s) Standard uncertainty velocity m/s
Sigma DP See Table 1 1 0.8 2.5 0.001 7.1 0.24Resolution uncertainty 0.00 2 0.2 2.4 0.009 4.0 0.38Calibration uncertainty 0.05 3Lack of fit 0.21 4Drift 5.28 5
67
Molar Mass 8u(H2O) 0 9(O2)wet 20.9 10u(O2)wet 0.00 11(CO2)wet 0.0 12u(CO2)wet 0.00 13(CO)wet 0.0 14u(CO)wet 0.00 15Oxygen sensitivity 4.00E‐05 16Water sensitivity 1.00E‐04 17CO2 sensitivity 1.60E‐04 18CO sensitivity 4.00E‐08 19
20standard uncertainty 0.000000 kg/mol 0.00 % of value Average 0.52 2.42440547 0.005 5.54 0.312370625
Temperaturestandard uncertainty 0.31 K 0.10 % of value
Stack static pressurestandard uncertainty 0.0 Pa #DIV/0! % of value
Stack pressurestandard uncertainty 997.5 Pa 1.00 % of value
Stack gas densitystandard uncertainty 0.0113 kg/m3 1.01 % of value
Standard uncertainty of velocity 0.10 m/sec 1.9 % of value
Expanded uncertainty in velocity 0.21 m/sec 3.8 % of value
Calculation spreadsheet v.48
22 of 33
Site Visit Report - SV10472 - Sperrin Galvanisers (Ireland) Limited Page 25 of 37
![Page 26: Site Visit Report · 2017-12-12 · HCl Impinger efficiency is lower than the requirements of 95% total of concentration in the first impinger (BS EN 1911:2010 section 5.2.1.2.2)](https://reader031.vdocuments.us/reader031/viewer/2022020413/5b5e59ca7f8b9a415d8c3a19/html5/thumbnails/26.jpg)
Fitz ScientificP0658-01CAR17-01Yar: 2017 Visit no: 1_________________________________________________________________________________________________________________________
Sperrin Galvanizers LimitedIndustrial Emissions Licence P0658-01
Volume flow rate associated uncertainties
Circular duct Rectangular ductArea uncertainty 0.01 m2 #DIV/0! m2
Flow rate standard uncertainty 262 m3/h #DIV/0! m3/h
Volume flow rate expanded uncertainty 525 m3/h #DIV/0! m3/h
Volume flow rate expanded uncertainty 4.0 % of value #DIV/0! % of value
Calculation spreadsheet v.4823 of 33
Site Visit Report - SV10472 - Sperrin Galvanisers (Ireland) Limited Page 26 of 37
![Page 27: Site Visit Report · 2017-12-12 · HCl Impinger efficiency is lower than the requirements of 95% total of concentration in the first impinger (BS EN 1911:2010 section 5.2.1.2.2)](https://reader031.vdocuments.us/reader031/viewer/2022020413/5b5e59ca7f8b9a415d8c3a19/html5/thumbnails/27.jpg)
Fitz ScientificP0658-01CAR17-01Yar: 2017 Visit no: 1_________________________________________________________________________________________________________________________
Sperrin Galvanizers LimitedIndustrial Emissions Licence P0658-01
Lookup tables
Factor Loading Function
Number of measurments dn2 0.8853 0.5914 0.4865 0.436 0.3957 0.378 0.3519 0.337
10 0.32511 0.31512 0.30715 0.28820 0.26825 0.25430 0.24540 0.22750 0.22260 0.21680 0.206
100 0.199
Calculation spreadsheet v.4824 of 33
Site Visit Report - SV10472 - Sperrin Galvanisers (Ireland) Limited Page 27 of 37
![Page 28: Site Visit Report · 2017-12-12 · HCl Impinger efficiency is lower than the requirements of 95% total of concentration in the first impinger (BS EN 1911:2010 section 5.2.1.2.2)](https://reader031.vdocuments.us/reader031/viewer/2022020413/5b5e59ca7f8b9a415d8c3a19/html5/thumbnails/28.jpg)
Fitz ScientificP0658-01CAR17-01Yar: 2017 Visit no: 1_________________________________________________________________________________________________________________________
Sperrin Galvanizers LimitedIndustrial Emissions Licence P0658-01
Swirl Test Record BS EN 16911-1:2013Company Sperrin Galvanizers Limited Date of Test 26/07/2017Site Derryfrench, Tynagh, Co Galway Reference No P0658-01Plant Identification A1 Operator Id MM11 1120Test carried out by Aadil Khan TE's TE1, TE2, TE3, TE4
Sampling Line APoint Distance to duct (cm) Diff. Pressure (Pa) Temp oC Velocity (m/s) Angle of Swirl
1 6.2 55.84 33.95 8.43 02 23 57.23 34.45 8.54 03 69 56.44 34.80 8.50 04 85.9 56.11 34.98 8.47 056789
101112
Average 56.40 34.55 8.48 0Min 55.84 33.95 8.43 0Max 57.23 34.98 8.54 0
Sampling Line BPoint Distance to duct (m) Diff. Pressure (Pa) Temp oC Velocity (m/s) Angle of Swirl
1 6.2 60.45 35.13 8.802 23 57.64 35.26 8.593 69 55.50 25.22 8.424 85.9 50.84 34.68 8.0556789
101112
Average 56.11 32.57 8.47 #DIV/0!Min 50.84 25.22 8.05 0Max 60.45 35.26 8.80 0
Calculation spreadsheet v.4825 of 33
Site Visit Report - SV10472 - Sperrin Galvanisers (Ireland) Limited Page 28 of 37
![Page 29: Site Visit Report · 2017-12-12 · HCl Impinger efficiency is lower than the requirements of 95% total of concentration in the first impinger (BS EN 1911:2010 section 5.2.1.2.2)](https://reader031.vdocuments.us/reader031/viewer/2022020413/5b5e59ca7f8b9a415d8c3a19/html5/thumbnails/29.jpg)
Fitz ScientificP0658-01CAR17-01Yar: 2017 Visit no: 1_________________________________________________________________________________________________________________________
Sperrin Galvanizers LimitedIndustrial Emissions Licence P0658-01
HCl BS EN 1911:2010Company Sperrin Galvanizers Limited Date of TestSite Derryfrench, Tynagh, Co Galway Reference NoPlant Identification A1 Operator IdTest carried out by Aadil Khan TE's
Report Number : P0658-01CAR17-01
Run Laboratory Results mgHCl/L Cert Number: Laboratory Accredtation Analytical Method Date of AnalysisLOD 0.069 Fitz Scientific MCERTS IC 03/08/2017Impinger 1 0.069 5790/623/11 Fitz Scientific MCERTSImpinger 2 0.069 5790/623/13 Fitz Scientific MCERTS
BlankImpinger 1 0.069 5790/623/12 Fitz Scientific MCERTSImpinger 2 0.069 5790/623/14 Fitz Scientific MCERTS
Run BlankSample Volumes
ml L ml L166.6 0.1666 140.4 0.1404124.4 0.1244 124.0 0.124
0.077373314 Nm3
HCl mg mgHCl/m3 at STP,DrymgCl/m3 at
STP
mgHCl/m3 at Refernce
ConditionsUncertainty mgHCl/mg HCl kg/hr
Uncertainty HCl kg/hr
LOD 0.02 0.3 0.3 0.3 n/a 0.0030 n/aRun 0.02 0.3 0.3 0.3 0.1 0.0030 0.00064Blank 0.02 0.2 0.2 0.2 0.1 0.0027 0.00058
Reference oxygen: 20.9 %Measured oxygen: 20.9 %
Flow Rate at reference conditions 11540.20 m3/hr
DeviationAbsorption efficiency(Impinger 1 should absorb 95% of total HCl): 42.7 % Low HCl levels dete TRUEor result in second absorber should be <LOD
Sampled Volume corrected to reference conditionsSTP, Dry
TE1, TE2, TE3, TE4
26/07/2017P0658-01
MM11 1120
Calculation spreadsheet v.48 26 of 33
Site Visit Report - SV10472 - Sperrin Galvanisers (Ireland) Limited Page 29 of 37
![Page 30: Site Visit Report · 2017-12-12 · HCl Impinger efficiency is lower than the requirements of 95% total of concentration in the first impinger (BS EN 1911:2010 section 5.2.1.2.2)](https://reader031.vdocuments.us/reader031/viewer/2022020413/5b5e59ca7f8b9a415d8c3a19/html5/thumbnails/30.jpg)
Fitz ScientificP0658-01CAR17-01Yar: 2017 Visit no: 1_________________________________________________________________________________________________________________________
Sperrin Galvanizers LimitedIndustrial Emissions Licence P0658-01
Uncertainty calculation for Determination of mass concentration of HCl, Reference method (taken from SO2 uncertainty STA website) v2Run Measurement EquationLimit value (ELV) 10 mg.m-3 Reference oxygen 20.9 % by volumeMeasured concen 0.3 mg.m-3 (at reference conditions)
Measured Quantit Symbol Value Standard uncertainty Units Uncertainty as pe Uncertainty at lv Requirement of stdSampled Volume Vm 0.077373314 uVm 0.001 m3 1.29 <=2%Sampled gas Tem Tm 307.6775 uTm 2 k 2.00 <2.5 kSampled gas Pres ρm 99.4615 uρm 1 kPa 1.01 <=1%Sampled gas Hum Hm 0 uHm 1 % by volume 1.00 <=1%Oxygen content O2,m 20.9 uO2,m 0.1 % by volume 0.48 <=5%Concentration in C 0.1380 uC 0.00414 mg/l 3.00 <5%Impinger solution VS 0.291 uVS 0.001 l 0.34 <1%Mass HCl m 0.0 um 0.00 mg 3.02 0.08 <5% of limit valueNote - Sampled gas humidity, temperature and pressure are values at the gas meteLeak L 2 % 2.00 <=2%
Intermediate calculationsFactor for std con fs 0.87uncertainty comp symbol sensitivity coeff u (in units of fs)
ρm 0.009 0.009Hm 0.009 0.009Tm 0.003 0.006ufs 0.014 1.56
Corrected volume V 0.07 uV 0.001 m3 2.15
Factor for O2 cor fc 1.00uncertainty comp symbol sensitivity coeff u
O2,m 1.00 0.100Factor for O2 Cor ufc 1.00 0.100 10.00
Parameter Value Units Sensitivity coe Uncertainty contribution Uncertainty as %Corrected Volume V 0.07 m3 3.85 0.01 mg.m-3 2.15 %Mass m 0.02 mg 12.92 0.01 mg.m-3 3.02 %Factor for O2 Corre fc 1.00 0.26 0.03 mg.m-3 10.00 %Leak L 0.00 mg.m-3 1.00 0.00 mg.m-3 1.15 %
Combined uncertainty 0.03 mg.m-3
Expanded uncertainty as percentage of measured val 21.46 % measured of value expressed with a level of confidence of 95%(Using a coverage factor k=2)
Expanded uncertainty in units of measurement 0.06 mg.m-3
Expanded uncertainty as percentqge of limit value 0.6 % ELV
Requirement in standard is for uncertainty to be < 20% at ELV at standard conditions
Calculation spreadsheet v.48 27 of 33
Site Visit Report - SV10472 - Sperrin Galvanisers (Ireland) Limited Page 30 of 37
![Page 31: Site Visit Report · 2017-12-12 · HCl Impinger efficiency is lower than the requirements of 95% total of concentration in the first impinger (BS EN 1911:2010 section 5.2.1.2.2)](https://reader031.vdocuments.us/reader031/viewer/2022020413/5b5e59ca7f8b9a415d8c3a19/html5/thumbnails/31.jpg)
Fitz ScientificP0658-01CAR17-01Yar: 2017 Visit no: 1_________________________________________________________________________________________________________________________
Sperrin Galvanizers LimitedIndustrial Emissions Licence P0658-01
Uncertainty calculation for Determination of mass concentration of HCl, Reference method (taken from SO2 uncertainty STA website) Blank
Limit value (ELV) 1 mg.m-3 Reference oxygen 20.9 % by volumeMeasured concen 0.2 mg.m-3 (at reference conditions)
Measured Quantit Symbol Value Standard uncertainty Units Uncertainty as pe Uncertainty at lv Requirement of stdSampled Volume Vm 0.077373314 uVm 0.001 m3 1.29 <=2%Sampled gas Tem Tm 307.6775 uTm 2 k 2.00 <2.5 kSampled gas Pres ρm 99.4615 uρm 1 kPa 1.01 <=1%Sampled gas Hum Hm 0 uHm 1 % by volume 1.00 <=1%Oxygen content O2,m 20.9 uO2,m 0.1 % by volume 0.48 <=5%Concentration in C 0.1380 uC 0.00414 mg/l 3.00 <5%Impinger solution VS 0.3 uVS 0.001 l 0.38 <1%Mass NH3 m 0.0 um 0.00 mg 3.02 0.71 <5% of limit valueNote - Sampled gas humidity, temperature and pressure are values at the gas meteLeak L 2 % 2.00 <=2%
Intermediate calculationsFactor for std con fs 0.87uncertainty comp symbol sensitivity coeff u (in units of fs)
ρm 0.009 0.009Hm 0.009 0.009Tm 0.003 0.006ufs 0.014 1.56
Corrected volume V 0.07 uV 0.001 m3 2.15
Factor for O2 cor fc 1.00uncertainty comp symbol sensitivity coeff u
O2,m 1.00 0.100Factor for O2 Cor ufc 1.00 0.100 10.00
Parameter Value Units Sensitivity coe Uncertainty contribution Uncertainty as %Corrected Volume V 0.07 m3 3.50 0.01 mg.m-3 2.15 %Mass m 0.02 mg 12.92 0.01 mg.m-3 3.02 %Factor for O2 Corre fc 1.00 0.24 0.02 mg.m-3 10.00 %Leak L 0.00 mg.m-3 1.00 0.00 mg.m-3 1.15 %
Combined uncertainty 0.03 mg.m-3
Expanded uncertainty as percentage of measured val 21.46 % measured of value expressed with a level of confidence of 95%(Using a coverage factor k=2)
Expanded uncertainty in units of measurement 0.05 mg.m-3
Expanded uncertainty as percentqge of limit value 5.1 % ELV
Calculation spreadsheet v.48 28 of 33
Site Visit Report - SV10472 - Sperrin Galvanisers (Ireland) Limited Page 31 of 37
![Page 32: Site Visit Report · 2017-12-12 · HCl Impinger efficiency is lower than the requirements of 95% total of concentration in the first impinger (BS EN 1911:2010 section 5.2.1.2.2)](https://reader031.vdocuments.us/reader031/viewer/2022020413/5b5e59ca7f8b9a415d8c3a19/html5/thumbnails/32.jpg)
Fitz ScientificP0658-01CAR17-01Yar: 2017 Visit no: 1________________________________________________________________________________________________________________________
Sperrin Galvanizers LimitedIndustrial Emissions Licence P0658-01
Company Sperrin Galvanizers Limited 42942.000Site Derryfrench, Tynagh, Co Galway P0658-01Plant Identification A1 MM11 1120Test carried out by Aadil Khan E1, TE2, TE3, TE4
Pres kPa Temp K Moisture % Oxygen % Run Cert Number Blank Cert Number Laboratory Accreditation
Ref Cond 101.3 273 0 20.90 Nozzle Wash 5790/623/09 Nozzle Wash 5790/623/10 RPS Salford MCERTS Run (ml) Blank (ml)
Stack Cond 99.4615 307.68 0.00 20.90 Line Wash Line Wash Analytical Me Date of Analysis Nozzle Wash 23.90 35.60
Filter 5790/623/07 Filter 5790/623/08 ICPMS 08/08/2017 Line WashStack Flow Rate at Reference Conditions 11540.20 m3/hr Impinger 1 5790/623/01 Impinger 1 5790/623/02 Impinger 1 107.30 127.10
Impinger 2 5790/623/03 Impinger 2 5790/623/04 Impinger 2 131.30 120.80Sampled Air Volume (STP, Dry) Impinger 3 5790/623/05 Impinger 3 5790/623/06 Impinger 3 146.60 115.80
Impinger 5 Impinger 5 Impinger 5 Impinger 6 Impinger 6 Impinger 6
Dry at Gas Meter: (Vg) 0.78 m3Gas Meter Temperature: (tg) 20.45 293.45 KAmbient Pressure Measured:(Pa) 99.45 KPaGas Volume STP (Vgn) 0.717 m3Gas Volume Factor Correction: 0.98Corrected Volume STP 0.704164592 m3
Lab Results Combined Combined LOD Results Results Mass Emission ELV Result as Absorption Result as a % LOD Filter Nozzle Line Impinger 1 Impinger 2 Impinger 3 LOD Sample LOD Results (STP) Adjusted for % of efficiency of total mass
Run 1 Results Wash Wash & Line Wash & Rinse & Rinse Result Results Result Corrected STP, Dry ref O2 ELV Run Impinger 3 metal collectedug ug/filter ug/L ug/L ug/L ug/L ug/L ug to ref O2 mg/Nm3 mg/Nm3 kg/hr mg/m3 % %
Cadmium - Cd 0.20 0.50 0.30 0.20 0.20 0.20 0.28 0.58 0.00040 #DIV/0! 0.00083 0.00083 0.00001 0.05 1.66 5.0 0.68377711Lead - Pb 0.30 0.30 0.50 20.00 1.00 6.00 0.42 3.47 0.00060 #DIV/0! 0.00493 0.00493 0.00006 0.10 4.93 25.4 4.06004729Zinc - Zn 1.00 16.00 20.00 576.00 8.00 14.00 77.01 81.39 0.10937 #DIV/0! 0.11558 0.11558 0.00133 0.20 57.79 2.5 95.2561756
Total Metals 0.11037 #DIV/0! 0.12133 0.12133 0.00140
Total for Cadmium – Cd and Thallim - Tl #REF! #DIV/0! #REF! #REF! #REF! #REF!
Total for Antimony- Sb, Arsenic – As, Lead – Pb, Chromium – Cr, Cobalt – Co, Cooper – Cu, Manganese – Mn, Nickel – Ni, Vanadium – V #REF! #REF! #REF! #REF! #REF! #REF!
Samples Volumes
Determination of Total Concentration of Metals (BS EN 14385:2004 excluding mercury, BS EN 13211:2001 Mercury)
Date of TestReference NoOperator Id
TE's
Calculation spreadsheet v.48 29 of 33
Site Visit Report - SV10472 - Sperrin Galvanisers (Ireland) Limited Page 32 of 37
![Page 33: Site Visit Report · 2017-12-12 · HCl Impinger efficiency is lower than the requirements of 95% total of concentration in the first impinger (BS EN 1911:2010 section 5.2.1.2.2)](https://reader031.vdocuments.us/reader031/viewer/2022020413/5b5e59ca7f8b9a415d8c3a19/html5/thumbnails/33.jpg)
Fitz ScientificP0658-01CAR17-01Yar: 2017 Visit no: 1________________________________________________________________________________________________________________________
Sperrin Galvanizers LimitedIndustrial Emissions Licence P0658-01
Lab Results Combined Mass Blank Filter Nozzle Line Impinger 1 Impinger 2 Impinger 3 Sample (STP) Adjusted Emission
Results Wash Wash & Line Wash & Rinse & Rinse Results for ref O2ug/filter ug/L ug/L ug/L ug/L ug mg/Nm3 mg/Nm3 kg/hr
Cadmium - Cd 10.00 0.30 0.20 0.20 0.20 10.08 0.01432 0.01432 0.00017Lead - Pb 0.30 0.20 0.20 0.20 0.60 0.43 0.00061 0.00061 0.00001Zinc - Zn 0.90 3.00 6.00 2.00 71.00 10.23 0.01453 0.01453 0.00017
Total Metals 0.029 0.029 0.00034
Total for Cadmium – Cd and Thallim - Tl #REF! #REF! #REF!
Total for Antimony- Sb, Arsenic – As, Lead – Pb, Chromium – Cr, Cobalt – Co, Cooper – Cu, Manganese – Mn, Nickel – Ni, Vanadium – V #REF! #REF! #REF!
0Notes: Calculated absorbtion efficiency
Absorption efficiency-Impinger 3 should absorb ≤10 % of total concentration:If one of the metals elements in the last impinger is > 10 % of total metal result result shall be rejected, unless the total result is < 30% of ELVor if the metal element is the <1% of total mass of metals collectedFor example ELVs for metals may be:• Cd and Tl combined – 0.05 mg/m3• Sb, As, Pb, Cr, Co, Cu, Mn, Ni, V combined – 0.5 mg/m3• mercury – 0.05 mg/m3For Cd and Tl combined it would not be necessary to comply with the less than 10% in the last impingercriteria, provided the overall combined Cd and Tl result for the sample train was below 0.015 mg/m3.For combined metals (Sb, As, Pb, Cr, Co, Cu, Mn, Ni, V) it would not be necessary for each individualelement to comply with the less than 10% in the last impinger criteria, provided that the overall combinedresult for the sample train was below 0.15 mg/m3.For mercury it would not be necessary to comply with the less than 10% in the last impinger criteria,provided the overall mercury result for the sample train was below 0.015 mg/m3.
Report Results
BOLD type indicates concentration of analyte at or below the limit of detection and the concemtration shown as calculated from the limit of detection for this sample
Calculation spreadsheet v.48 30 of 33
Site Visit Report - SV10472 - Sperrin Galvanisers (Ireland) Limited Page 33 of 37
![Page 34: Site Visit Report · 2017-12-12 · HCl Impinger efficiency is lower than the requirements of 95% total of concentration in the first impinger (BS EN 1911:2010 section 5.2.1.2.2)](https://reader031.vdocuments.us/reader031/viewer/2022020413/5b5e59ca7f8b9a415d8c3a19/html5/thumbnails/34.jpg)
Test Certificate Date 07/08/2017
Fitz Scientific
Unit 35 Boyne Business Park
Drogheda
County Louth
Ireland
Client Order No. FS534
WK17-5390Certificate No.
Issue No. 1
Contact 31/07/2017Date ReceivedKatherine McQuillan
Description 10 samples for metals Technique ICP Stack
Analysis Method Accreditation Method LOD UncertaintyParameter
M31-BSEN14385 F-0.2ug :W-0.3ug :S-0.2ug/l 15.00%Cadmium UKAS
M31-BSEN14385 F-0.2ug :W-0.3ug :S-0.2ug/l 15.00%Cadmium UKAS
M31-BSEN14385 F-0.3ug :W-0.2ug :S-0.2ug/l 13.00%Lead UKAS
M31-BSEN14385 F-1.0ug :W-1.0ug :S-2.0ug/l 11.00%Zinc UKAS
Sample No. 947332 5790/623/01 Method
M31-BSEN14385(U)Cadmium <0.2 ug/l 98 mls
M31-BSEN14385(U)Lead 20 ug/l
M31-BSEN14385(U)Zinc 576 ug/l
Sample No. 947333 5790/623/02 Method
M31-BSEN14385(U)Cadmium <0.2 ug/l 120 mls
M31-BSEN14385(U)Lead <0.2 ug/l
M31-BSEN14385(U)Zinc 6 ug/l
Sample No. 947334 5790/623/03 Method
M31-BSEN14385(U)Cadmium <0.2 ug/l 122 mls
M31-BSEN14385(U)Lead 1 ug/l
M31-BSEN14385(U)Zinc 8 ug/l
Sample No. 947335 5790/623/04 Method
M31-BSEN14385(U)Cadmium <0.2 ug/l 114 mls
M31-BSEN14385(U)Lead <0.2 ug/l
M31-BSEN14385(U)Zinc <2 ug/l
RPS Laboratories Ltd. Unit 12. Waters Edge Business Park. Modwen Road. Salford. M5 3EZ
Tel: (0161) 872 2443 Fax: (0161) 877 3959
Page 1 of 3
31 of 33Site Visit Report - SV10472 - Sperrin Galvanisers (Ireland) Limited Page 34 of 37
![Page 35: Site Visit Report · 2017-12-12 · HCl Impinger efficiency is lower than the requirements of 95% total of concentration in the first impinger (BS EN 1911:2010 section 5.2.1.2.2)](https://reader031.vdocuments.us/reader031/viewer/2022020413/5b5e59ca7f8b9a415d8c3a19/html5/thumbnails/35.jpg)
Date 07/08/2017Test Certificate
WK17-5390Certificate No.
1Issue No.
Client Fitz Scientific
Sample No. 947336 5790/623/05 Method
M31-BSEN14385(U)Cadmium <0.2 ug/l 140 mls
M31-BSEN14385(U)Lead 6 ug/l
M31-BSEN14385(U)Zinc 14 ug/l
Sample No. 947337 5790/623/06 Method
M31-BSEN14385(U)Cadmium <0.2 ug/l 110 mls
M31-BSEN14385(U)Lead 0.6 ug/l
M31-BSEN14385(U)Zinc 71 ug/l
Sample No. 947338 5790/623/07 Method
M31-BSEN14385(U)Cadmium 0.5 ug
M31-BSEN14385(U)Lead <0.3 ug
M31-BSEN14385(U)Zinc 16 ug
Sample No. 947339 5790/623/08 Method
M31-BSEN14385(U)Cadmium 10 ug
M31-BSEN14385(U)Lead <0.3 ug
M31-BSEN14385(U)Zinc 0.9 ug
Sample No. 947340 5790/623/09 Method
M31-BSEN14385(U)Cadmium <0.3 ug 21 mls
M31-BSEN14385(U)Lead 0.5 ug
M31-BSEN14385(U)Zinc 20 ug
Sample No. 947341 5790/623/10 Method
M31-BSEN14385(U)Cadmium <0.3 ug 32 mls
M31-BSEN14385(U)Lead <0.2 ug
M31-BSEN14385(U)Zinc 3 ug
RPS Laboratories Ltd. Unit 12. Waters Edge Business Park. Modwen Road. Salford. M5 3EZ
Tel: (0161) 872 2443 Fax: (0161) 877 3959
Page 2 of 3
32 of 33Site Visit Report - SV10472 - Sperrin Galvanisers (Ireland) Limited Page 35 of 37
![Page 36: Site Visit Report · 2017-12-12 · HCl Impinger efficiency is lower than the requirements of 95% total of concentration in the first impinger (BS EN 1911:2010 section 5.2.1.2.2)](https://reader031.vdocuments.us/reader031/viewer/2022020413/5b5e59ca7f8b9a415d8c3a19/html5/thumbnails/36.jpg)
Date 07/08/2017Test Certificate
WK17-5390Certificate No.
1Issue No.
Client Fitz Scientific
Approved By Date
Calum GreenTested By 03/08/2017Date
For and on authority of RPS Laboratories Ltd.
Method Symbols (U) Analysis is UKAS Accredited
(N) Analysis is not UKAS Accredited
Concentration values (mg/m3 and ppm) are calculated on the basis of information provided by the customer.
Results stated as ml are refering to the sample volume.
Analysis carried out on samples 'as received'
This document may not be reproduced other than in full, except with the written approval of the issuing laboratory.
RPS Laboratories terms and conditions apply - a copy is available on request.
07/08/2017
Joanne Dewhurst
Operational Manager
RPS Laboratories Ltd. Unit 12. Waters Edge Business Park. Modwen Road. Salford. M5 3EZ
Tel: (0161) 872 2443 Fax: (0161) 877 3959
Page 3 of 3
33 of 33Site Visit Report - SV10472 - Sperrin Galvanisers (Ireland) Limited Page 36 of 37
![Page 37: Site Visit Report · 2017-12-12 · HCl Impinger efficiency is lower than the requirements of 95% total of concentration in the first impinger (BS EN 1911:2010 section 5.2.1.2.2)](https://reader031.vdocuments.us/reader031/viewer/2022020413/5b5e59ca7f8b9a415d8c3a19/html5/thumbnails/37.jpg)
Summary
FOLLOW-UP ACTIONS
You are required to complete the instructions and actions, as outlined in this report, within the specified timeframe. Where required, you shall respond to actions specified in Compliance Investigations within the required timeframe.The licensee shall maintain documentary evidence, for review by the EPA, that the prescribed corrective actions were completed within the required timeframe.
(i) Compliance Investigations
You are not required to respond directly to items contained in this EPA site visit report; where an issue requires a direct response, the EPA will generate a Compliance Investigation through the EDEN system. You will receive notification when a Compliance Investigation instruction or action is generated.
(ii) Publication of reports and licensee response.
Please note that this Site Visit Report will be made available for public viewing via the EPA’s Licence Enforcement Access Portal within one day of the issue date and will be published on the Licence Details Page of the EPA’s website, www.epa.ie, that relates to your licence 60 calendar days after the issue date.
You may if you choose submit, within 45 calendar days of the issue date of this Site Visit Report, a Licensee Public Response that will be published alongside the Site Visit Report. This Response, should you wish to avail of it, provides you with an opportunity to inform the public about how you are implementing the actions set out in the report, activities underway, timescales and target completion dates. Please be aware that the content of your Licensee Public Response must be factual and should not breach the EPAs stated online publication standards.
If you wish to submit a Licensee Public Response to an EPA Site Visit Report, you should do this by clicking on the ‘Make a Response’ link on the Site Visits page in EDEN. A .pdf document containing your response can be attached and submitted from here.
(iii) Response to Site visit report
Where you do wish to respond directly to a site visit report, you should do this by generating a ‘Licensee Return’ of the type ‘Site Updates/Notifications’ and the sub-type ‘Response to EPA Report’ in EDEN.
Please note that you are required to comply with the conditions of your licence at all times, and where noncompliance occurs you must restore compliance within the shortest possible time. These actions will be verified during subsequent EPA visits.
Please quote the above Inspection Reference Number in any future correspondence in relation to this Report.
Site Visit Report - SV10472 - Sperrin Galvanisers (Ireland) Limited Page 37 of 37