single phase or commercial 3 phase operation field ... · 3 phase operation field convertible 9...
TRANSCRIPT
Advanced Heating & Hot Water Systems
Industry Best 10 Year Commercial Warranty
Single Phase or 3 Phase OperationField Convertible
9 Models: 10 to 115 Gal.
Point of UseSingle Phase Only
CommerCial
Large Volume3 Phase
Junction Box &Terminal Block for Easy
Wiring & Conversion(Large Volume 3 Phase Models)
MediuM duty
tHerMOStAt And HiGH liMit COntrOlS: Adjustable temperature range up to 181º Fon all models
tHe FineSt PrOteCtiOn: laser welded with a concentrated heat source producing high quality, long-lasting welded joints. 316 L stainless steel tank (lightweight) - Superior corrosion resistance, eliminates the need for anode rods, protects against harsh water conditions for a lifetime of durability against leaks - limited 10 year warranty (with online registration, 5 if not registered)
MiniMAl HeAt lOSS: Heavy-duty insulation3" on the top & 2" on the sides
inCOlOy & StAinleSS Steel eleMentS: Low watt density, incoloy sheathed and stainless steel screw plugs increase corrosion resistance and helps prevent scale build-up for longer element life versus conventional elements - 98% efficient heat transfer
NO ANODE RODS NEEDED
RESISTSSCALE BUILD UP
LIGHT WEIGHT
the everlast Commercial electric Water Heater combines high quality stainless steel construction and energy efficient operation, providing long draws of hot water without consuming large amounts of energy. Durable components, low standby heat losses, high recovery rates, and the industry ’s strongest warranty make the Everlast Commercial Electric Water Heater an ideal choice for electric water heating needs.
STANDARD FEATURES- 316L Stainless Steel Tank- Heavy Duty Insulation- Heat Traps- Incoloy & Stainless Steel Elements- Electrical Connection Box- Limited 10 year warranty (with online registration, 5 year warranty if not registered)
IN THE BOX- T & P Relief Valve- Installation Manual- Brass Full Port Drain Valve- Dip Tube & Outlet Nipple (30-40-50-80-100-115 Models) Combination Cold Inlet & Drain Fitting (10-15-20 Models) – Thermostat and high limit controls / Adjustable temperature range – Provides the finest protection against harsh water conditions with the best warranty in the industry – Directs cold water to the bottom of the tank and minimizes mixing of cold water providing long draws of hot water– Single phase or 3 phase operation • Field convertible (30-40-50-80-100-115 Models)
Two Stainless Steel Incoloy Elements
Drain
Hot Outlet
Cold Inlet
Electrical Junction Box & Terminal Block
T&P Valve T&P Valve - Alternate Hot Outlet
Product Ships with Installed Elements
– Standard: Two 240 volt, three phase, non-simultaneous (unbalanced) configuration with 4500W elements (available in other configurations) – Water heaters can be converted to single phase and/or simultaneous operation in the field (dual element models only).
– Top inlet with dip tube directs cold water to the bottom of the tank, minimizing the mixing of cold and heated water and providing long draws of hot water– 3/4” inlet and outlet nipples constructed of durable brass
45.00° 45.00°
RELIEF VALVE
TEMPERATUREPRESSURE
ELEMENT &THERMOSTATACCESS
TANKDRAIN
B
C
D
A
E
HOT WATEROUTLET
COLD WATERINLET
ELECTRICALACCESS PANEL
45.00° 45.00°
RELIEF VALVE
TEMPERATUREPRESSURE
ELEMENT &THERMOSTATACCESS
TANKDRAIN
B
C
D
A
E
HOT WATEROUTLET
COLD WATERINLET
ELECTRICALACCESS PANEL
Specifications and dimensions (3 Phase Option) Water temperature ratings
Models Gal. A B C d eShippingWeight
Est.
Hot/ColdWater Inlets
MinimumDelivered
Temp.
MaximumDelivered
Temp.
HighTemp. Limit
EVC030C2T045 30 6” 34” 42.25” 19.5”
8”
89 lbs
¾”NPT
120°F48.8°C
179.9°F82.1°C
200°F93.3°C
EVC040C2T045 40 6” 46” 54.25” 19.5” 104 lbsEVC050C2T045 50 6” 58” 66.75” 19.5” 118 lbsEVC080C2T045 80 6.5” 60" 69” 23.25” 151 lbsEVC100C2T045 100 7.25” 52" 61” 27” 206 lbsEVC115C2T045 115 7.25” 60” 69” 27” 224 lbs
Input Wattage
Single and Three Phase Non-Simultaneous Operation
208 Volts
240 Volts
277 Volts
480 Volts
3,000 14.4 12.5 10.8 6.3
4,000 19.9 16.7 14.4 8.3
4,500 21.6 18.8 16.8 9.4
5,000 22.8 20.8 18 10.4
5,500 - 22.9 19.2 11.5
6,000 - 25 21.6 12.5
Input Wattage
Simultaneous Operation
208 Volts 240 Volts 277 Volts 480 Volts
Single Phase
Three Phase
Single Phase
Three Phase
Single Phase
Three Phase
Single Phase
Three Phase
6,000 28.9 25 25 21.6 24.1 20.8 12.5 10.8
8,000 39.7 34.4 33.3 28.8 28.9 25 16.7 14.4
9,000 43.3 37.4 37.5 32.4 33.7 29.1 18.8 16.2
10,000 45.7 39.5 41.7 36 36.1 31.2 20.8 18
11,000 - - 45.8 39.7 38.5 33.3 22.9 19.8
12,000 - - 49.9 43.2 43.3 37.4 25 21.7
Gallons# Elements and
ThermostatsNon-Simultaneous Simultaneous 120 208 240 277 480
30, 40, 50, 80, 100,
1152
3,000 6,000
NO
YES YESNO
YES
3,500 7,000 YES YES NO
4,000 8,000 YES YES YES YES
4,500 9,000 YES YES YES YES
5,000 10,000 YES YES YES YES
5,500 11,000NO
YES YES YES
6,000 12,000 YES YES YES
Input Wattage
Single and Three Phase Non-Simultaneous Operation
208 Volts
240 Volts
277 Volts
480 Volts
3,000 14.4 12.5 10.8 6.3
4,000 19.9 16.7 14.4 8.3
4,500 21.6 18.8 16.8 9.4
5,000 22.8 20.8 18 10.4
5,500 - 22.9 19.2 11.5
6,000 - 25 21.6 12.5
Input Wattage
Simultaneous Operation
208 Volts 240 Volts 277 Volts 480 Volts
Single Phase
Three Phase
Single Phase
Three Phase
Single Phase
Three Phase
Single Phase
Three Phase
6,000 28.9 25 25 21.6 24.1 20.8 12.5 10.8
8,000 39.7 34.4 33.3 28.8 28.9 25 16.7 14.4
9,000 43.3 37.4 37.5 32.4 33.7 29.1 18.8 16.2
10,000 45.7 39.5 41.7 36 36.1 31.2 20.8 18
11,000 - - 45.8 39.7 38.5 33.3 22.9 19.8
12,000 - - 49.9 43.2 43.3 37.4 25 21.7
Gallons# Elements and
ThermostatsNon-Simultaneous Simultaneous 120 208 240 277 480
30, 40, 50, 80, 100,
1152
3,000 6,000
NO
YES YESNO
YES
3,500 7,000 YES YES NO
4,000 8,000 YES YES YES YES
4,500 9,000 YES YES YES YES
5,000 10,000 YES YES YES YES
5,500 11,000NO
YES YES YES
6,000 12,000 YES YES YESAMPERAGES
EVERLAST MDCOMMERCIAL
lArGe vOluMe 3 PHASe EVC030, EVC040, EVC050
EVC080, EVC100 & EVC115
60.00°48.75°
45.00° 45.00°
RELIEF VALVETEMPERATURE/PRESSURE
ELEMENT ANDTHERMOSTATACCESS
TANKDRAIN
B
C
A
D
3/4" F-NPTRELIEF VALVE
TEMP/PRESSURE
COLD WATERINLET
ELEMENT ANDTHERMOSTAT ACCESSA
B
C
D
HOT WATER OUTLET
ELECTRICAL ACCESS PANEL
020CVE ,510CVE ,010CVE
050CVE040CVE030CVE
EVC080EVC100 EVC115
HOT WATEROUTLET
COLD WATERINLET
ELECTRICALACCESS PANEL
Gallons # of Elements
AvailableWattage
Voltage (and Element Part #)Phase
120 208 240 277
10
15
20
1
1,500 A1X015N B1X015N C1X015N D1X015N
1
2,000 A1X020N B1X020N C1X020N D1X020N
2,500 A1X025N B1X025N C1X025N D1X025N
3,000 A1X030N B1X030N C1X030N D1X030N
3,500 - B1X035N C1X035N D1X035N
4,000 - B1X040N C1X040N D1X040N
4,500 - B1X045N C1X045N D1X045N
5,000 - B1X050N C1X050N D1X050N
InputWattage
AMPERAGES - Single Phase Operation / Non-Simultaneous Operation
120 208 240 277
1,500 13 8 7 6
2,000 17 10 9 8
2,500 21 13 11 10
3,000 25 14.4 12.5 10.8
3,500 - 16.3 14.6 12.1
4,000 -- 19.9 16.7 14.4
4,500 - 21.6 18.8 16.8
5,000 -- 22.8 20.8 18
Specifications and dimensions ( Single Phase Only) Water temperature ratings
Models Gal. A B C dShippingWeight
Est.
Hot/ColdWater Inlets
MinimumDelivered
Temp.
MaximumDelivered
Temp.
HighTemp. Limit
UEF
EVC010C1X045 10 4.5” 10.25” 17.5” 19.5” 42 lbs
¾”NPT
120° F48.8°C
179.9° F82.8°C
200° F93.3°C
TBD
EVC015C1X045 15 4.5” 16.25” 23.5” 19.5” 46 lbs .88
EVC020C1X045 20 4.5” 21.75” 29” 19.5” 50 lbs .92
Product Ships with Installed Elements
EVERLAST MDCOMMERCIAL
POint OF uSeSinGle PHASe
EVC010, EVC015& EVC020
T& P Valve - Alternate Hot Outlet
Stainless Steel Incoloy Element
316L StainlessSteel Tank
Connection Box
Cold Inlet & Drain Fitting
Hot Outlet
Stainless Steel Screw-in Plug
– Standard: Single Phase, 240V Configuration
with 4500W Element
– Electric Junction Box located on top of water
heater for easy wiring and installation
– 3/4” inlet and outlet nipples constructed of
stainless steel
– Bottom cold water inlet directs cold water to the
bottom of the tank, minimizing the mixing of
cold and heated water and providing long
draws of hot water
CommerCial
Many CoMMerCialappliCations
Recovery Table for Commercial Electric Water Heater (US Gallons per Hour)
Input Temperature Rises (deg. F)W BTU 40 50 60 70 80 90 100 110 120 130 140
1500 5118 15 12 10 9 8 7 6 5 5 5 42000 6824 20 16 13 11 10 9 8 7 7 6 62500 8530 25 20 17 14 13 11 10 9 8 8 73000 10236 30 24 20 17 15 13 12 11 10 9 93500 11942 35 28 23 20 18 16 14 13 12 11 104000 13649 41 32 27 23 20 18 16 15 13 12 114500 15355 46 36 30 26 23 20 18 16 15 14 135000 17061 51 40 34 29 25 22 20 18 17 15 145500 18767 56 44 37 31 28 24 22 20 18 17 166000 20473 61 48 41 34 30 27 24 22 20 18 177000 23885 70 56 47 40 35 31 28 25 23 22 20 8000 27297 80 64 53 46 40 36 32 29 27 25 239000 30709 90 72 60 51 45 40 36 33 30 28 26
10000 34121 100 80 67 57 50 44 40 36 33 31 2911000 37534 110 88 73 63 55 49 44 40 37 34 3112000 40946 120 96 80 69 60 53 48 44 40 37 34
CommerCial eleCtriC • reCoverY
Our Components are Made of Durable Materials: The Advantages
Minimizes Scale Build Up Prolongs Tank Life
No Need for Anode RodsLightweight Construction
Stainless Steel VS Glass -Lined
HTP’s Stainless Steel Tank
Lightweight
Top Competitor’s Glass-lined Tank
Ver y Heav y
All coated tanks require a n o d e s t o d e l a y t h e i n e v i t a b l e c o r r o s i o n a n d t a n k f a i l u re . Th e a v e r a g e c o a t e d w a t e r h e a t e r l a s t s a b o u t 1 3 y e a r s . T h e E v e r l a s t s t a i n l e s s s t e e l t a n k w i l l o u t l a s t a ny co ate d steel tank in the market.
NO Anode Rods Needed!
SCAle Build uP
316L Stainless Steel Tank Construction
Stainless Steel Incoloy Element
Inlet and Outlets Constructed of Durable Brass(30-40-50-80-100-115 Models)
Stainless Steel Dual Port Outlets(10-15-20 Models)
MKTLIT-49 • 05 / 2017 © HTP In accordance with our company policy of ongoing product improvement, HTP Inc. reserves the right to make changes without prior notice.
2 7 2 D u c h a i n e B l v d , N e w B e d f o r d , M A 0 2 7 4 5 • w w w. h t p r o d u c t s . c o m
Input Rating(100’s of Watts)
ElementConstruction
Rated VoltageA = 120 B = 208C = 240
Number of Elements
Phase/OperationX = Single Phase - StagedW = Single Phase - Simultaneous T = 3 Phase
D= 277E = 480
N = Stainless SteelScrew-InC2X030N
MODEL NUMBERSPRODUC T ORDERING INFORMATION
EverlastCommercial Electric Stainless
Volume In Gallons
EVC 020
Gallons Total Wattage
Recovery at90˚ F Rise
First Hour Delivery
10 / 15 / 20 1,500 7 14 / 17.5 / 21
10 / 15 / 20 2,000 9 16 / 19.5 / 23
10 / 15 / 20 3,000 14 21 / 24.5 / 28
10 / 15 / 20 4,000 18 25 / 28.5 / 32
10 / 15 / 20 4,500 20 27 / 30.5 / 34
10 / 15 / 20 5,000 23 30 / 33.5 / 37
30/40/50/80/100/115 6,000 27 48/55/62/83/97/107.5
30/40/50/80/100/115 9,000 41 62/69/76/97/104/121.5
30/40/50/80/100/115 10,000 46 67/74/81/102/116/126.5
30/40/50/80/100/115 12,000 55 76/83/90/111/125/135