en United Kingdom These instructions should be read in conjunction with the Boiler Installation and Service Instructions. Please leave with the user when completed. Instruction manual for Installers and Users Single Channel Digital Programmer Override Extra Hour Mode DAY/ PROG RUN TIME OK Holidays OFF am Thu AUTO ONCE CONT EXT HOUR +1 +2 +3 ON1 Select

Upload: others

Post on 23-Jun-2022

1 views

Category:

Documents


0 download

TRANSCRIPT

Page 1: Single Channel Digital Programmer Ecoblue - Baxi Boilers

enUnited Kingdom

These instructions should be read in conjunction with the Boiler Installation and Service Instructions.Please leave with the user when completed.

Instruction manual for Installers and Users

Single Channel Digital Programmer

Override

Extra Hour

Mode

DAY/ PROG RUNTIME

OK

Holidays

OFF

am

Thu

AUTOONCECONT

EXT HOUR+1+2+3

ON1

Select

Page 2: Single Channel Digital Programmer Ecoblue - Baxi Boilers

2 EcoBlue Accessories 7212551

Page 3: Single Channel Digital Programmer Ecoblue - Baxi Boilers

Contents

3EcoBlue Accessories7212551

Section Page

1. Introduction1.1 General energy information 41.2 Description of the device 41.3 Designated use 51.4 Technical data 5

2. Fitting the Controller2.1 Installation and mounting 62.2 General siting information 62.3 Wiring and wall mounting 6

3. Operation & Configuration3.1 Quick start guide 73.2 Guide to button functions 73.3 Commissioning 83.4 To alter the time and date 93.5 To show a digital time display and change

AM/PM time display to 24 hour clock 10

4. Setting the Heating Programmes4.1 Running a default programme 114.2 Selecting a programme type and

a default programme 124.3 Weekly programming days or blocks 134.4 5-2 programming 134.5 Daily programming 134.6 Setting time periods 14

5. Operating Mode5.1 Using the mode button 155.2 Override mode 155.3 Extra hour mode 155.4 Holiday mode 16

6. Installer Information6.1 Installer menu 176.2 Disposal 19

Page 4: Single Channel Digital Programmer Ecoblue - Baxi Boilers

4 EcoBlue Accessories

1. Introduction

7212551

Warning

Danger! Risk of electric shock! Installation must be carried out by a person competent to do so!

Before removal from backplate, the device must be disconnected from the power supply!Interferences and changes to the device will invalidate the warranty and guarantee rights.Maximum diameter of the cable for the terminals is 2 x 2.5 mm2.Read and observe these instructions fully to ensure the correct operation of the device and a safeoperation.

1.1 General energy informationWhat is a programmer?...an Explanation for Householders(as recommended by the Energy Savings Trust)

Programmers allow you to set ‘ON’ and ‘OFF’ time periods. Some models switch the centralheating and domestic hot water on and off at the same time, while others allow the domestic hotwater and heating to come on and go off at different times. Set the ‘ON’ and ‘OFF’ time periods tosuit your own lifestyle. On some programmers you must also set whether you want the heating andhot water to run continuously, run under the chosen ‘ON’ and ‘OFF’ heating periods, or bepermanently off.

The time on the programmer must be correct. Some types have to be adjusted in spring andautumn at the changes between Greenwich Mean Time and British Summer Time. You may beable to temporarily adjust the heating programme, for example, ‘Override’, ‘Advance’, or ‘Boost’.These are explained in the manufacturer’s instructions. The heating will not work if the roomthermostat has switched the heating off. And, if you have a hot-water cylinder, the water heatingwill not work if the cylinder thermostat detects that the hot water has reached the correcttemperature.

1.2 Description of the deviceYour single channel programmer provides timing control for your central heating, letting you set ONand OFF periods to suit your own lifestyle.

Backlit LCD DisplayReal Time ClockUp to 3 ON/OFF per dayAutomatic summertime / wintertime changeoverDaily, weekly and week-weekend programming possibilityDifferent running modes: OFF, AUTO, ONCE, CONTINUOUS and HOLIDAYSManual override functionManual extra hour function3 different pre-programmed profiles, customisable by user

Page 5: Single Channel Digital Programmer Ecoblue - Baxi Boilers

1. Introduction

5EcoBlue Accessories7212551

1.3 Designated useThe programmer is used to control central heating zone systems or combi boilers.Suitable for use in dry rooms only!Do not install in the vicinity of devices which generate inductive discharges (motors, transformers,etc.)

1.4 Technical dataDimensions H x W x D (mm) 95 x 148 x 36Weight g (approx.) 285Power supply 230 V AC / 50-60 HzPower consumption < 3 WPower reserve >2hSwitching capacity 3 A 250 V ~ resistive, cos φ = 1

3 A 250 V ~ inductive, cos φ = 0.6Time display 24 h or 12 h AM/PM formatTime setting resolution:- Time of day 1 min.- Programmes / min. switching 1 min.Programmes Selectable (daily , weekly, or week-weekend)Number of switchings per day 3 ON/OFF pairs

(2 ON/OFF pairs selectable)Operating temperature range 0°C ... + 45°CAmbient temperature -20°C ... + 55°CHumidity range 10 to 90% RH, non condensingAccuracy Type ± 1 sec./day at +20°CTerminal capacity 2 x 2,5 mm2Protection type IP 30European standards EN60730-2-7

Compliant with building regulations(Part L UK) (Part J Scotland)

Page 6: Single Channel Digital Programmer Ecoblue - Baxi Boilers

6 EcoBlue Accessories

2. Fitting the Controller

7212551

2.1 Installation and mounting

WarningDanger! Risk of electric shock! Installation mustbe carried out by a person competent to do so!

2.2 General siting information

Identify a suitable site to locate the unit. Fig. 1gives guidance on optimum positioning and sitingrestrictions.

Do not place behind curtains.Do not place above or below sources of heat.

2.3 Wiring and wall mounting

Undo the retaining screw underneath theprogrammer. Fig. 2(a). Insert a screwdriver asshown and carefully prise the programmer looseand lift away from backplate.Wiring can be routed from behind or if surfacemounted, through the breakout tab to the left ofthe retaining screw at the bottom of the backplate.Fix the backplate to the wall using the screwsprovided.Connect the wiring into the backplate connectorsas shown in Fig. 3.The input to terminal 1 may be supplied from themains supply or from the boiler wiringconnections as appropriate to the applianceused. Please consult the relevant boiler instructions forfurther guidance.Replace the programmer on the backplate andpress firmly down to fully engage the contact pinsand tighten the screw underneath theprogrammer.

1.5 m

N L 1 2 3 4

N

INPUT

OFF ON

OUTPUT TO ROOMTHERMOSTAT / BOILER

times

witc

h /

prog

ram

mer

wal

lpla

te

L

Fig. 3. Wiring diagram

Fig. 2. Mounting the controller

Fig. 1. Siting

a

d

ec

b

Page 7: Single Channel Digital Programmer Ecoblue - Baxi Boilers

3. Operation & Configuration

7EcoBlue Accessories7212551

3.1 Quick start guide

1. Connect mains power.

2. Press OK three times.

The default Standard programme runs.You can control the unit with the Override, ExtraHour or Mode buttons.

Please read the full instructions if you want toknow more.

3.2 Guide to button functions

A Day of the week indicatorB Current day, month, yearC Central heating operating mode indicatorD Central heating override buttonE Central heating extra hour buttonF Central heating operating mode buttonG Central heating indicator lampH Central heating extra hour indicationI Central heating programming period indication

J Select indicator lampsK SelectL OK buttonM “-” and “+” buttonN1 Holiday buttonO1 Holiday iconP Information text lineQ Analogue clock / current timeR Warning icon

Override

Extra Hour

Mode

DAY/ PROG RUNTIME

OK

Holidays

OFF

am

Thu

AUTOONCECONT

EXT HOUR+1+2+3

ON1

Select

A

DR

Q

PO1

N1

M

E

FGHIJ

L K

B C

Override

Extra Hour

Mode

OK

Page 8: Single Channel Digital Programmer Ecoblue - Baxi Boilers

Select day with + and -buttons and confirm with OK.

DAILY The same ON/OFF time schedule is used every day.

WEEKLY A different time schedule can be programmed for each day.

5-2 One time schedule is used for Mon-Fri and a different one can be used for Sat & Sun.

OK

2

Select your program type with +and - buttons and confirm with OK.

OK

1

Select month with + and -buttons and confirm with OK.

OK

3

Select year with + and -buttons and confirm with OK.

OK

4

Select hour with + and -buttons and confirm with OK.

OK

5

Select minutes with + and -buttons and confirm with OK.

OK

6

The date and time are saved.The programmer goes toRUN mode

OK

7

8 EcoBlue Accessories

3. Operation & Configuration

3.3 CommissioningConnect the programmer to the power. The product name and version are displayed briefly.

7212551

Page 9: Single Channel Digital Programmer Ecoblue - Baxi Boilers

3. Operation & Configuration

3.4 To alter the time and date

9EcoBlue Accessories7212551

Press the SELECT buttons until DAY/TIME light is lit.

DAY/ PRG RUN

Select

TIME

1

Select day with + and -buttons and confirm with OK.

OK

2

Select month with + and -buttons and confirm with OK.

OK

3

Select year with + and -buttons and confirm with OK.

OK

4

Select hour with + and -buttons and confirm with OK.

OK

5

Select minutes with + and -buttons and confirm with OK.

OK

6 The date and timeare saved.

Press the right handSELECT button toselect RUN mode.

OK

7

DAY/ PRG RUN

Select

TIME

Page 10: Single Channel Digital Programmer Ecoblue - Baxi Boilers

10 EcoBlue Accessories

3. Operation & Configuration

3.5 To show a digital time display and change AM/PM time display to 24 hour clock

7212551

DAY/ PRG RUN

Select

TIME

OK

1

OK

2

OK

3

Press the SELECT buttons until RUN light is lit.

Press and hold + & - buttonstogether for 10 seconds.

Press OK

Press OKOK

4

Press -

OK

5

Press OKOK

6

Press OK

OK

7

Press + or -OK

8

Press OK

Press + seven timesto exit menu.

Page 11: Single Channel Digital Programmer Ecoblue - Baxi Boilers

4. Setting the Heating Programmes

4.1 Running a default programme

11EcoBlue Accessories7212551

The default programmes can be selected in the INSTALLER MENU. To access the installer’smenu, the device must be working in RUN mode.

Default programme STD (DEFAULT) Daily ON1: 06:30 am ON2: 12:00pm* ON3: 04:30 pm

OFF1: 08:30 am OFF2: 12:00pm* OFF3: 10:30 pm

Weekly ON1: 06:30 am ON2: 12:00pm ON3: 04:30 pmOFF1: 08:30 am OFF2: 01:00pm OFF3: 10:30 pm

5-2 ON1: 06:30 am ON2: 12:00pm ON3: 04:30 pm Mon - FriOFF1: 08:30 am OFF2: 01:00pm OFF3: 10:30 pmON1: 06:30 am ON2: 12:00pm ON3: 04:00 pm Sat - SunOFF1: 09:30 am OFF2: 01:00pm OFF3: 10:30 pm

Default programme HOME Daily ON1: 06:30 am ON2: 12:00pm* ON3: 04:00 pm

OFF1: 09:30 am OFF2: 12:00pm* OFF3: 11:00 pm

Weekly ON1: 06:30 am ON2: 12:00pm ON3: 04:00 pmOFF1: 09:30 am OFF2: 01:00pm OFF3: 11:00 pm

5-2 ON1: 06:30 am ON2: 12:00pm ON3: 04:30 pm Mon - FriOFF1: 09:30 am OFF2: 01:00pm OFF3: 11:00 pmON1: 06:30 am ON2: 12:00pm ON3: 04:00 pm Sat - SunOFF1: 09:30 am OFF2: 01:00pm OFF3: 11:30 pm

Default programme ECO Daily ON1: 06:30 am ON2: 12:00pm* ON3: 05:30 pm

OFF1: 07:30 am OFF2: 12:00pm* OFF3: 10:00 pm

Weekly ON1: 08:30 am ON2: 12:00pm ON3: 05:30 pmOFF1: 09:30 am OFF2: 01:00pm OFF3: 10:00 pm

5-2 ON1: 06:30 am ON2: 12:00pm ON3: 05:30 pm Mon - FriOFF1: 07:30 am OFF2: 12:00pm OFF3: 10:00 pmON1: 08:30 am ON2: 12:00pm ON3: 05:30 pm Sat - SunOFF1: 09:30 am OFF2: 01:00pm OFF3: 10:30 pm

Press OK

Press -

Three programme types are possible on the programmer

DAILY The same ON/OFF time schedule is used every day.

WEEKLY A different time schedule can be programmed for each day.

5-2 One time schedule is used for Mon-Fri and a different one can be used for Sat & Sun.

For each programme type, three default programmes are provided. These have been designed toprovide heating at typical times throughout the day. The default programmes give you a startingpoint that you can personalise to your own requirements, please see the section 4.3 - 4.5.

You can choose the desired programme in the INSTALLER MENU as shown overleaf. Every programme has three pairs of ON/OFF switching times per day. Each time can be set between 3.00 am and 2.50 am (on the next day).*On/off periods with the same time cancel out - no switching will occur.

Page 12: Single Channel Digital Programmer Ecoblue - Baxi Boilers

12 EcoBlue Accessories

4. Setting the Heating Programmes

4.2 Selecting a programme type and a default programme

7212551

DAY/ PRG RUN

Select

TIME

OK

1

OK

2

OK

3

OK

4

Press OK.

Press + four times untilprogram type is displayed.

Press OK.

With the + & - buttons, scrollthrough and select programme type.

Press OK to select.

OK

5

OK

6

Press +.

OK

7

With the + & - buttons, scroll through andselect setting (STD,HOME or ECO).

Press OK to select.

Press + twice to leave menu.

Press OK to select.

Press the SELECT buttons until RUN light is lit.

Press and hold + & -buttons together for10 seconds.

Page 13: Single Channel Digital Programmer Ecoblue - Baxi Boilers

4. Setting the Heating Programmes

4.3 Weekly programming days or blocks

13EcoBlue Accessories7212551

DAY/ PRG RUN

Select

TIME

OK

Thu Fri Sat SunWedTueMon

ON1am

On DAILY programme, all days are automaticallyselected and the setting for the first ON period isdisplayed.

Go to Section 4.6.

OK

Mon

Days

DAY/ PRG RUN

Select

TIME

1 Press the SELECT buttons until PRGlight is lit.

Use +/- to choose aday to set theprogramme for.

Press OK.

OK

Mon Tue Wed Thu Fri

Days

Press the SELECT buttons until the PRG light is lit.On 5-2 programme, Monday - Friday can be selectedand Saturday - Sunday selected as separate blocks.

Use +/- to choose the required block of days.

Press OK. Go to Section 4.6.

OK

Mon2

To set the programmerfor more than one day,press OK.

OK

Mon4

OK

Mon Tue

Days

3Use +/- to choose additional days.

Press OK.

Repeat this processuntil all the desired dayshave been selected. On the last day selected,

choose NO for ADDDAYS and press OK.Go to Section 4.6

You have the option to edit each day individually or you can create dayblocks, e.g. Tue, Wed, Friand Sat, where you can set the same ON and OFF sequence. Days you do not select will keep the preset values.

4.4 5-2 programming

4.5 Daily programming

Page 14: Single Channel Digital Programmer Ecoblue - Baxi Boilers

14 EcoBlue Accessories

4. Setting the Heating Programmes

4.6 Setting time periods

7212551

DAY/ PRG RUN

Select

TIME

OK

Thu Fri Sat SunWedTueMon

ON1am

1 Once the requireddays have beenselected, the first ONtime is displayed.

Press + & - toadjust ON1 time.

Press OK. OK

Thu Fri Sat SunWedTueMon

OFF1am

2

Press + & - to adjust OFF1 time.

Press OK.

OK

Thu Fri Sat SunWedTueMon

ON2

pm

3

OK

Thu Fri Sat SunWedTueMon

OFF2

pm

4

Press + & - to adjust OFF2 time.

Press OK.

Press + & - to adjust ON2 time.

Press OK.

OK

Thu Fri Sat SunWedTueMon

ON3

pm

DAY/ PRG RUN

Select

TIME

5

OK

Thu Fri Sat SunWedTueMon

OFF3

pm

6

7

Press + & - to adjust OFF3 time.

Press OK.

The screen returns to SELECTDAYS (or to ON1 for DAILYprogrammes).

Press the SELECT buttons untilRUN light is lit.

The programme is now saved.

Press + & - to adjust ON3 time.

Press OK.

If you make any changes, you mustpress OK to confirm ALL ON/OFF pairsbefore pressing the SELECT button toreturn to the RUN mode otherwise yourchanges will be lost.

Page 15: Single Channel Digital Programmer Ecoblue - Baxi Boilers

5. Operating Mode

15EcoBlue Accessories7212551

5.1 Using the mode button

The operating mode may only be changed when RUN mode isactivated (green indicator lamp RUN must be ON). Pressingthe MODE button cycles through the following options:

OFF The system will remain OFF.

AUTO The system will be switched ON and OFF according to the set programme.

ONCE The heating will come on at the first programmed ON time and go OFF at the last programmed OFFtime.

CONT The system will remain ON continuously.

5.2 Override mode

The Override function (temporary programme override) allowsthe user to end the current running programme prematurely orstart a programme running before its scheduled start. Thisdepends on the current channel status. The Override functionapplies only to the current program and remains active untilthe next programme change. After that, the programmerreturns to AUTO mode.The Override function is only available when the device isrunning in AUTO and ONCE operating mode.

Press OVERRIDE once to activate.Press OVERRIDE again to cancel.

5.3 Extra hour mode

The extra hour button allows you to switch the system ON forup to 3 extra hours without altering the programme. When theblue central heating indicator lamp is OFF, pressing theEXTRA HOUR button switches the heating ON for just onehour. When the blue central heating indicator lamp is ON,pressing an EXTRA HOUR button extends the programmedON period by one hour. Further presses of the EXTRA HOURbutton will increase the extra hour period by one hour for eachbutton press, up to a maximum of 3 hours. To cancel the extrahours, press the EXTRA HOUR button until the message EXTHOUR disappears from the display. The system returns toprevious status.

OFF OFFOFF ONON

OFFOFF

Example 1

ExampleAUTO mode

OFFBack to AUTO

ONON

ON OFFOFF

Example 2

OFF

Back to AUTO

ON

OVERRIDE

OVERRIDE

DAY/ PRG RUN

Select

TIME

OK

Override

Extra Hour

ModeOFFAUTOONCECONT

+1+2+3

ON1

OFF OFFOFF ONON

ON ONOFF OFFOFF

(1 to 3 hours)

(1 to 3 hours)

Example 1

OFFON

ON OFFOFF

Example 2

OFFON

Extra Hour

Extra Hour

ExampleAUTO mode

Page 16: Single Channel Digital Programmer Ecoblue - Baxi Boilers

16 EcoBlue Accessories

5. Operating Mode

7212551

5.4 Holiday mode

The Holiday function allows you to switch OFFyour heating system when you are away fromhome, but resumes normal operation on the dayof your return.

1. Make sure the device is working in RUNmode.

2. Press the HOLIDAY button.

3. Select desired numbers of days, + or - andconfirm with OK.

Holiday mode is activated.

To cancel the Holiday function, just press theHOLIDAY button again. If you use the holidayfunction during winter you should ensure that youhave a secondary frost protection device in yoursystem to prevent frost damage.

DAY/ PRG RUN

Select

TIME

OK

OFFAUTOONCECONT

+1+2+3

ON1

Holidays

Page 17: Single Channel Digital Programmer Ecoblue - Baxi Boilers

6. Installer Information

17EcoBlue Accessories7212551

6.1 Installer menu

The programmer has a special installer’s menuwhere some features can be adjusted to suit yourlifestyle or preferences. To access to installersmenu (INST MENU) the device must be workingRUN mode (green indicator lamp RUN must beON).

To save your settings, continue scrolling throughthe menu options with + key, until you once againsee INST MENU / – OK + and leave theinstaller’s menu with the + key.

To cancel the installer’s menu, press the selectbutton.The following settings are possible:

DAY/ PRG RUN

Select

TIME

OK

1

OK

2

OK

3

Press the SELECT buttons until RUN light is lit.

Press and hold + & - buttonstogether for 10 seconds.

Press OK

Press + or - to scrollthrough installer menu

Page 18: Single Channel Digital Programmer Ecoblue - Baxi Boilers

18 EcoBlue Accessories

6. Installer Information

7212551

6.1 Installer menu

DIGI CLOCK: Shows the current time (hours/minutes) in a digital and analogue clock formatSetting possibilities:NO: Digital clock not shown (Default value).YES: Digital clock shown. If digital clock is set YES, you can choose between 12 HRS (AM-PM) or24 HRS format.

BACKLIGHT: Setting possibilities:PERMANENT ON: Backlight always ON.PERMANENT OFF: Backlight always OFF.BUTTON PRESSED: Backlight ON when any pushbutton is pressed. Backlight goes OFF 20seconds after the last button press (Default value).

S/W CHANGE: Automatic Summer/Winter time change. Summer time starts on the last Sunday ofMarch (1:00 am to 2:00 am) and ends on last Sunday of October (2:00am to 1:00am), then Wintertime starts.Setting possibilities:ON: S/W time change will be done automatically (Default).OFF: S/W time change must be done manually.

PROG TYPE: Menu to select daily, week-weekend, weekly programming. This value will beapplied by central heating programming method.Setting possibilities:Daily: All days (Monday - Sunday) are programmed with the same ON/OFF time schedule.Weekly: You can program each day (Monday, Tuesday, ...) with a different ON/OFF time schedule5-2: You can program Monday - Friday with a ON/OFF time schedule and Saturday - Sunday witha different one.

NR PERIODS: The number of adjustable time periods defined by ON-OFF pairs to control the timeprogrammes.Setting possibilities:3 ON-OFF: adjust maximum 3 ON-OFF time periods (Default value).2 ON-OFF: adjust maximum of 2 ON-OFF time periods.

DEFAULT PRGS: Time programme that will appear by default when running in AUTO mode or asbase point to customize according to users lifestyle.Setting possibilities:STDHOMEECOFor detailed explanation of the profiles, see Section 4.1 “Running a default programme”

RESET: Reset all parameters of installation menu to factory default.

To leave the installer’s menu press the + key.

Page 19: Single Channel Digital Programmer Ecoblue - Baxi Boilers

6. Installer Information

19EcoBlue Accessories7212551

6.2 Disposal

Dispose of the packaging materials correctlyaccording to legal requirements and regulations.

Please recycle where possible.

Do not throw electrical and electroniccomponents in the bin. These should be taken toa recycling centre.

Page 20: Single Channel Digital Programmer Ecoblue - Baxi Boilers

All descriptions and illustrations provided in this leaflet have beencarefully prepared but we reserve the right to make changes andimprovements in our products which may affect the accuracy of theinformation contained in this leaflet. All goods are sold subject to ourstandard Conditions of Sale which are available on request.

7212551 - 1 (03/14)

BAXIA Trading Div is ion of Baxi Heat ing UK Ltd (3879156)

Brooks House, Coventry Road, Warwick. CV34 4LLWebsite www.baxi.co.uke&oe