sharqawi - air distribution system factory co. - access door...sharqawi air distribution systems co....
TRANSCRIPT
-
• On Time Delivery • According to Standard• Customization • Quality • Cooperation
008 LA CATALOG REV 00JANUARY 2019
ACCESS DOOR
-
Sharqawi Air Distribution Systems Co. Factory, has been in the market since 1995, as one leading manufacturer in the kingdom of Saudi Arabia in the field of fabrication of HVAC duct and its Accessories. Upon whose satisfaction we have been allowed to grow and prosper in this highly competitive marketplace.
As one of the leading HVAC ducts and its accessories manufacturers, our reason of ’being’ is a combination of our vision, mission, and values.
Vision: We aspire making Sharqawi the most trusted manufacturer of HVAC ducts and its accessories in the Kingdom of Saudi Arabia, region and the world.
Mission:To aim for design perfection and expanding our market-share by enhancing our marketing, satisfying customer requirements, complying with the international quality standards and consistently sustaining our improvement program.
Values:Our values reflect who we are and our reason for being.
Quality: We provide exquisite products that deliver exceptional values to our customer.
Integrity: We boost the highest integrity in all of our activities and operations.
Customer commitment: we develop positive relationships that make a beneficial influence on our client’s business.
Teamwork: We work together across boundaries to meet the expectations of our customers and support the company to win.
A Will To Win: We exhibit a strong will to win in the marketplace and every aspect of our business.
Respect for people: We value our people, encourage their development and reword their performance.
Good residents: We are good residents in the communities in which we live and work.
Personal Accountability: We are personally accountable for delivering on our commitment.
ABOUT US
-
A c c e s s D o o r
1
Installation Options
ACCESS DOOR MODELS
Description
Access doors are ruggedly designed to suit client individual requirements, to provide easy access into air duct, in low to high pressure and velocity ventilation systems
Standard Features• SMACNA Standard Access Door
• DOOR: Consists of 2 Sheets, Mechanically locked together
• FRAME: Wide range of sizes, MIN (100X100)mm, MAX (610x610)mm
• CAM: Secured to the door with rivet
• INSULATION: High density fiber glass type
• GASKET: Neoprene Gasket Between frame and Door to min leakage
LEAKAGE, CFM/ Ft2
ACCESS DOOR [LA-C] LEAKAGE1 INCH DOOR THICKNESS
STA
TIC
PR
ESSU
RE,
INC
H W
.G.
1
10
10 100
LA-A (REMOVABLE)
Fixation On Rectangle Duct
LA-B (PIANO HINGE)
Fixation On Round Duct
LA-C (HINGED) LA-D (INSPECTION COVER)
Access Door with Window
-
A c c e s s D o o r
2
CONSTRUCTION
6 5 2 31
4
AB WxH
(W+40) x (H+40)
1. Fram 2. Door 3. Cam Lock 4. Sealing Gasket 5. Insulation 6. Hinges
A. Door Thickness B. Neck Length (Default 25 Mm, For Double Wall B= 25+ Wall Thickness)
Number of cam lock and sheet metal gauge as per SMACNA table below (All types except LA-D)
Door Size No. Hinges No. LocksMetal Gage
Frame Door Back
2” w.g. Static and less
12”x12” 2 1-S 24 26 26
16”x20” 2 2-S 22 24 26
24”x24” 3 2-S 22 22 26
3” w.g. Static
12”x12” 2 1-S 22 22 26
16”x20” 2 1-S,1-T,1-B 20 20 26
24”x24” 3 2-S,1-T,1-B 20 20 24
4” w.g.
to
10” w.g
12”x12” 2 1-S,1-T,1-B 20 20 26
16”x20” 3 2-S,1-T,1-B 20 18 24
24”x24” 3 2-S,2-T,2-B 18 18 24
S = Side opposite hinges, T = Top, B = Bottom
CONSTRUCTION AND AIRTIGHTNESS MUST BE SUITABLE FOR THE DUCT PRESSURE CLASS USED
REFERENCE: FIGURE 7-2 DUCT ACCESS DOOR AND PANELS, [SMACNA] HVAC Duct Standards Metal and Flexible. Third Edition
-
A c c e s s D o o r
3
INSPECTION COVERLA-D for Mounting on Circular Ducts
ød A B
80 180 80
100 180 80
112 180 80
125 180 80
140 200 100
150 200 100
160 200 100
180 200 100
200 200 100
224 200 100
250 200 100
280 200 100
315 200 100
ød A B
355 300 200
400 300 200
450 300 200
500 300 200
560 400 300
630 400 300
710 400 300
800 400 300
900 400 300
1000 500 400
1120 500 400
1250 500 400
All dimensions in mm
Ordering Code Example:
Inspection Cover for Circular Duct with Outer Diameter 500mm:
LA-DMG1N0-500x1
-
A c c e s s D o o r
4
ASSEMBLY INSTRUCTION
3. Add Gasket 4. Place The Access Door
5. Open The Door And Bend All Sides Dovetail 6. Close The Door With CAM Lock
1. Use Access Door To Mark Neck On The Duct 2. Cut The Duct
-
A c c e s s D o o r
5
ORDERING CODE
ACCESS DOOR LA - C M G 1 N 0 - 500 x 550 * All selection checkboxes highlighted in blue are the default selections (if not otherwise specified) 1 2 3 4 5 6
WID
TH [100-610] m
m
HEIG
HT [100-610] m
m
MODEL 1
A REMOVABLE B PIANO HINGE
C INDIVIDUAL HINGES D INSPECTION COVER
PRESSURE 2
L 0-2 Inch W.G M 2-4 Inch W.G
H 4-6 Inch W.G
MATERIAL 3
G GALVANIZED STEEL [G90] S STAINLESS STEEL [S304]
B BLACK STEEL
GALVANIZED STEEL [Default G90, Optional (G115, G90 Japan)], STAINLESS STEEL [Default S304, Optional S316]
DOOR THICKNESS 4
1 1 Inch 2 2 Inch
WINDOW 5
N WITHOUT WINDOW W WITH WINDOW
FINISHING 6
0 NO PAINT NO PACKAGING 1 PAINT ONLY
2 PACKAGING ONLY 3 PAINT & PACKAGING
CODE DESCRIPTION EXAMPLE (LA-CMG1N0-500x550)
ACCESS DOOR, MODEL INDIVIDUAL HINGES TYPE, PRESSURE 2-4 Inch W.G, MATERIAL GALVANIZED STEEL [G90], DOOR THICKNESS 1 Inch, FALSE, FINISHING NO PAINT NO PACKAGING , WxH= 500x550mm
ADDITIONAL OPTIONS
FULL WELD FRAME DOUBLE WALL DUCT THICKNESS [0.5-2.0] Inch
1 FIRE RATED GASKET INSULATION TYPE [1] FIBER GLASS, [2] ROCKWOOL]
1 FIRE RATED PAINT INSULATION DENSITY [DENSITY] kg/m^3
1 FIXATION ON ROUND SURFACE,OUTER DIAMETER (mm) REMOVABLE TYPE WITH CHAIN
-
• On Time Delivery • According to Standard• Customization • Quality • Cooperation
008 LA CATALOG REV 00JANUARY 2019
ACCESS DOOR