4
Benefits Function Very compact low-profile design Secure & flexible plate fixation Central zero selfpositioning Ideal rpm for 96/384 plates Low-speed start-up Shaking Teleshake & Teleshake 1536 Orbital/linear shaking

Upload: others

Post on 26-Aug-2020

0 views

Category:

Documents


0 download

TRANSCRIPT

Page 1: Shaking - INHECO€¦ · SBS) format for verification of temperature and/or shaking performance. The IMP can be used on heating, cooling, shaking devices and inside incubation chambers

Benefits

Function

Very compact low-profile design

Secure & flexible plate fixation

Central zero selfpositioning

Ideal rpm for 96/384 plates

Low-speed start-up

ShakingTeleshake & Teleshake 1536

Orbital/linear shaking

Page 2: Shaking - INHECO€¦ · SBS) format for verification of temperature and/or shaking performance. The IMP can be used on heating, cooling, shaking devices and inside incubation chambers

Teleshake & Teleshake 1536

Product Description

The Teleshake and Teleshake 1536 have a very compact and low-profile design with a height of only 39 and 56mm, respectively. The small footprint makes them ideal for integration into auto-mation platforms. Plates with up to 384 wells can be used on the Teleshake while the Teleshake 1536 is ideal for plates with 384 up to 1536 wells that need higher shaking frequency. Both ver-sions have a precise automated zero positioning (centric position precision: ± 0.1mm) that al-lows a comfortable robotic gripping. Plates are securely fixed during shaking with a mechanism that is easily adaptable for different plates. Shaking frequency (100-2,000rpm for Teleshake and 4,000-8,500rpm for Teleshake 1536) and shaking pattern (linear & orbital) is comfortably adjusted. A low-speed startup process prevents spillage. The Teleshakes are high performance plug-and-play shaking devices that can be operated in standalone with a control module, or with a PC via RS232 interface. Daisy chaining of up to 14 instruments is possible.

Teleshake

Secure & flexible plate fixationIdeal frequency for 96 & 384 plateAlso for vials, reservoirs & troughsShaking speed: 100 to 2,000 rpm Orbital or linear shakingAmplitude 2 or 3mmCentral zero self-positioningFrequency infinitely selectable

Premium shaking devicesSmall footprint – & very compact design for robotics integration

3800047 Teleshake & Accessories

* Each shaker includes a Control Module (Power supply & RPM control). Further country specific versions available.

3800074 Teleshake-1536-8

Teleshake 1536

Ideal frequency for 1536 well platesHigh speed shaking: 4,000 - 8,500 rpmMicroplate locking systemSmall fixing pads for easy gripper accessOrbital or linear shakingAmplitude 0.1-1mm adjustableCentral zero self-positioningOptional plate lift function

Product* PartNo. Tubes Wells

RPM Amplitude DimensionsW x D x H (mm)

Teleshake 230V EU 3800047 1-384 100 - 2,000 2 mm

103 x 146 x 39

Teleshake 115V US 3800048 1-384 100 - 2,000 2 mm

Teleshake 230V UK 3800049 1-384 100 - 2,000 2 mm

Teleshake 100V JP 3800050 1-384 100 - 2,000 2 mm

Teleshake 230V EU 3800063 1-384 100 - 2,000 3 mm

Teleshake 115V US 3800064 1-384 100 - 2,000 3 mm

Teleshake 1536-6, 100V JP 3800044

Teleshake 1536-8, 230V EU 3800072

Teleshake 1536-8, 115V US 3800074

Monoshake 115V 3800080 1-384 100 - 2,000 2 mm 103 x 146 x 40

384-15364,000 - 8,500

0.1 to 1.0mm

103 x 145 x 56

Page 3: Shaking - INHECO€¦ · SBS) format for verification of temperature and/or shaking performance. The IMP can be used on heating, cooling, shaking devices and inside incubation chambers

Alternatives

For the heated and cooled shaker units, we refer to the heating & shaking (Teleshake 95) and heating, cooling, shaking (Thermoshake & Thermoshake AC) brochure.

3800044 Teleshake-1536-6with Control Module

Performance Teleshake

The maximum shaking frequency depends on the selected amplitude and the total weight of loaded plate and liquid volume. The graph below shows the correlation between speed and load for Teleshake with 2mm amplitude (red line) and Teleshake with 3mm amplitude (blue line). At a given load, higher maximum shaking frequencies can be used with the 2mm amplitude shaker. Whether a higher shaking frequency or a higher amplitude is needed for the liquid in your assay needs to be tested. The minimal frequency that can be used is 100rpm for 2 & 3 mm amplitude versions. The maximum load of 500g should not be exceeded.

Comparison of 2mm with 3mm amplitude and maximum speed at different loads

Verification PlateINHECO offers a compact and precise measurement plate (IMP) in ANSI/SLAS (formerly SBS) format for verification of temperature and/or shaking performance. The IMP can be used on heating, cooling, shaking devices and inside incubation chambers. We refer to the IMP brochure for more information.

Product Part No. Dimension W x D x H (mm)

Weight Temp. Range

IMP 7901000 87.5 x 128 x 14.9 100 g 4°C to 60°C

7901000: INHECO Measurement Plate (IMP)

7100146 Thermoshake Classic (back)7100160 Thermoshake AC (front)

Teleshake Performance

2mm, Teleshake (3800047) 3mm, Teleshake (3800064)

load speed load speedin g in rpm in g in rpm

Without load 0 2000 Without load 0 2000MP empty 40,28 2000 MP empty 40,28 1700Dummy 83,76 2000 Dummy 83,76 1500MP 118,83 1800 MP 118,83 1400Dummy 254,5 1400 Dummy 254,5 1100Dummy 500g 500 1200 Dummy 500g 500 800

Minimum speed (frequency) of both versions, 2mm & 3mm, is 100rpm. Shaking of 500g with 100rpm is possible. Maximum load is 500g.Tests were done with a shaking duration between 1 and 2 minutes.Tested Teleshakes were fixed to the ground with screws.

0100200300400500600700800900

10001100120013001400150016001700180019002000

0 50 100 150 200 250 300 350 400 450 500

spee

d, fr

eque

ncy

[rpm

]

load [g]

comparison 2mm with 3mm amplitude max. speed at different loads

2mm, Teleshake (3800047)

3mm, Teleshake (3800064)

INHECO GmbH, Fraunhoferstr. 11, 82152 Martinsried, Germany, phone +49 89 899 593 102, [email protected]

Page 4: Shaking - INHECO€¦ · SBS) format for verification of temperature and/or shaking performance. The IMP can be used on heating, cooling, shaking devices and inside incubation chambers

INHECO GmbHFraunhoferstrasse 1182152 MartinsriedGermany

Tel.: +49 89 89 95 93 -101Fax: +49 89 89 95 [email protected]

www.inheco.comThis brochure can also be downloaded from our website.

BRO_09-12-19_TELESHAKE2020_01

20

Drawings Teleshake Drawings Teleshake 1536-6