setting up a ps series storage array · setting up a ps series storage array turn the page for...

1
R716M Rev. A00 PS Series Storage Arrays PS6000 Hardware Installation Before You Begin Environmental Requirements Make sure the installation location meets the power, cooling, and ventilation requirements in the PS6000 Rack Mount Instructions document, located in the array shipping box. Networking Requirements Standard Ethernet and TCP/IP networking rules apply to a PS Series SAN. Gigabit Ethernet is recommended for optimal performance. Required Hardware (Not Supplied) Standard 19-inch four-pole rack. One to eight network cables. Supported cables include Category 5E and Category 6 cables with RJ45 connectors. Use Category 5 cables only if they meet the TIA/EIA TSB95 standard. Step 1: Unpack the Shipping Box See the PS6000 Unpacking Instructions document, located in the array shipping box. Make sure you have all the required hardware, including the rack and network cables, which are not supplied. Protect sensitive hardware. Make sure you use an electrostatic wrist strap or a similar form of protection when handling hardware. Read the documentation. The PS Series Release Notes document contains the latest product information. Rail Kit for Four-Pole Rack including Fasteners Electrostatic Wrist Strap Step 5: Connect the Array to the Network Recommended configuration. For high performance and availability, connect network cables to all the network interfaces and distribute the connections across multiple network switches. The switches must be connected with interswitch links that have sufficient bandwidth. Step 6: Turn on Power to the Array A power switch is located below the power plug on each power supply and cooling module. Turn on both. Once you turn on full power to an array, batteries may start to charge and hardware components may start to synchronize. Array LEDs will indicate these normal activities. Power Cables Power cables for various electrical configurations may be supplied. If not, contact your PS Series support provider. Serial Cable Used for non-Windows installations and when there is no network access to the array or group. Setting Up a PS Series Storage Array Turn the page for software configuration instructions. Hardware installation is complete. Front of chassis (disk drive slots) Rear of chassis (access to power buttons, two control modules and two power supply and cooling modules) PS6000 Chassis - - - z - - - z Address ID ! ! D LL E CONTROL MODULE 7 D LL E CONTROL MODULE 7 - - - z - - - z Invalid Address ID ! ! D LL E CONTROL MODULE 7 D LL E CONTROL MODULE 7 Information in this document is subject to change without notice. 2008 Dell EqualLogic. All rights reserved. Reproduction in any manner whatsoever without the written permission of Dell EqualLogic, is strictly forbidden. The Dell EqualLogic logo is a trademark of Dell, Inc. Copyright 2008 Dell, Inc. PS6000 Bezel Step 2: Install the Array in a Rack Mount the array in a four-pole 19-inch rack. See the PS6000 Rack Mount Instructions document, located in the array shipping box. Read the PS6000 Rack Mount Instructions. The array is heavy. Do not attempt to lift the array without assistance. Stabilize the rack. Dell recommends that you attach the rack to the floor for added stability. ! Step 3: Install the Bezel To install the bezel: 1. Facing the front of the rack, fit the right side of the bezel into the right side of the chassis. 2. Push the bezel toward the chassis until the left side of the bezel engages with the chassis. 3. Insert the bezel key and turn it counter-clockwise to lock the bezel to the chassis. Make sure you store the key in a safe location. Step 4: Connect the Array to Power Minimum configuration. Use the power cables shipped with the array to connect each power supply and cooling module to separate sources of power if possible. Use the cable strain relief to secure each power plug to the array. See the PS Series Storage Arrays Installation and Setup Manual. A PS6000 requires at least 1 power supply connected to a source of power to operate. Recommended configuration. For high availability, connect the power supplies to different sources of power on separate circuits. If possible, use uninterruptible power supply (UPS) systems. 3 2 1

Upload: others

Post on 15-Aug-2020

1 views

Category:

Documents


0 download

TRANSCRIPT

Page 1: Setting Up a PS Series Storage Array · Setting Up a PS Series Storage Array Turn the page for software configuration instructions. Hardware installation is complete. Front of chassis

R716M Rev. A00

PS Series Storage ArraysPS6000 Hardware InstallationBefore You BeginEnvironmental RequirementsMake sure the installation location meets the power, cooling, andventilation requirements in the PS6000 Rack Mount Instructionsdocument, located in the array shipping box.

Networking RequirementsStandard Ethernet and TCP/IP networking rules apply to aPS Series SAN.

Gigabit Ethernet is recommended for optimal performance.

Required Hardware (Not Supplied)Standard 19-inch four-pole rack.

One to eight network cables. Supported cables include Category 5Eand Category 6 cables with RJ45 connectors. Use Category 5cables only if they meet the TIA/EIA TSB95 standard.

Step 1: Unpack the Shipping BoxSee the PS6000 Unpacking Instructions document, located in thearray shipping box. Make sure you have all the required hardware,including the rack and network cables, which are not supplied.

Protect sensitive hardware. Make sure you use an electrostaticwrist strap or a similar form of protection when handling hardware.

Read the documentation. The PS Series Release Notesdocument contains the latest product information.

Rail Kit for Four-Pole Rack including Fasteners

Electrostatic Wrist Strap

Step 5: Connect the Array to the NetworkRecommended configuration. For high performance andavailability, connect network cables to all the network interfacesand distribute the connections across multiple network switches.The switches must be connected with interswitch links thathave sufficient bandwidth.

Step 6: Turn on Power to the ArrayA power switch is located below the power plug on eachpower supply and cooling module. Turn on both.

Once you turn on full power to an array, batteries may start tocharge and hardware components may start to synchronize. Array LEDs will indicate these normal activities.

Power CablesPower cables for various electrical configurationsmay be supplied. If not, contact your PS Seriessupport provider.

Serial CableUsed for non-Windows installations and whenthere is no network access to thearray or group.

Setting Up a PS Series Storage Array

Turn the page for software configuration instructions.Hardware installation is complete.

Front of chassis (disk drive slots)

Rear of chassis (access to power buttons,two control modules and two power supplyand cooling modules)

PS6000 Chassis

- - - .

.

.. z - - - .

.

.. z

InvalidAddress

ID

!!

D LLE

CO

NTR

OL M

OD

ULE 7

D L

LE

CO

NTR

OL

MO

DU

LE 7

- - - .

.

.. z - - - .

.

.. z

InvalidAddress

ID

!!

D LLE

CO

NTR

OL M

OD

ULE 7

D L

LE

CO

NTR

OL

MO

DU

LE 7

Information in this document is subject to change without notice.2008 Dell EqualLogic. All rights reserved.

Reproduction in any manner whatsoever without the written permission ofDell EqualLogic, is strictly forbidden.

The Dell EqualLogic logo is a trademark of Dell, Inc.

Copyright 2008 Dell, Inc.

PS6000 Bezel

Step 2: Install the Array in a RackMount the array in a four-pole 19-inch rack. See the PS6000 RackMount Instructions document, located in the array shipping box.

Read the PS6000 Rack Mount Instructions.

The array is heavy. Do not attempt to lift the array without assistance.

Stabilize the rack. Dell recommends that you attach the rack to the floor for added stability.

!

Step 3: Install the Bezel

To install the bezel:

1. Facing the front of the rack, fit the right side of the bezel into the right side of the chassis.

2. Push the bezel toward the chassis until the left side of the bezel engages with the chassis.

3. Insert the bezel key and turn it counter-clockwise to lock the bezel to the chassis. Make sure you store the key in a safe location.

Step 4: Connect the Array to PowerMinimum configuration. Use the power cables shipped withthe array to connect each power supply and cooling module toseparate sources of power if possible. Use the cable strainrelief to secure each power plug to the array. See the PS Series Storage Arrays Installation and Setup Manual.

A PS6000 requires at least 1 power supply connected toa source of power to operate.

Recommended configuration. For high availability, connectthe power supplies to different sources of power on separatecircuits. If possible, use uninterruptible power supply(UPS) systems.

3

2

1