Series A-C 2000 50 Hz CLOSED COUPLED & FRAME MOUNTED CENTRIFUGAL PUMP PERFORMANCE CURVES CURVES CAC200050 R1 Series 2000 Frame Mounted Series 2000 Closed Coupled

Upload: others

Post on 22-Jan-2021

12 views

Category:

Documents


0 download

TRANSCRIPT

Page 1: Series A-C 2000 - Xylem Applied Waterdocumentlibrary.xylemappliedwater.com/wp-content/blogs...1450 rPM — 50 Hz PuMP Curves PAGE 27 serIes AC 2000 50 Hz Goulds Water Technology 1)

Series A-C 2000 50 HzCloSed Coupled & FrAme mounted CentriFugAl pump perFormAnCe CurveS

CurvesCAC200050 R1

series 2000 Frame Mounted

series 2000 Closed Coupled

Page 2: Series A-C 2000 - Xylem Applied Waterdocumentlibrary.xylemappliedwater.com/wp-content/blogs...1450 rPM — 50 Hz PuMP Curves PAGE 27 serIes AC 2000 50 Hz Goulds Water Technology 1)

TABLe OF CONTeNTs

Useful Pump Formulas ………………………………… 3

50 Hz Range Curves …………………………………… 4

Selection Charts ………………………………………… 5

2900 rpm – 50 HZ pump CurveS

1.5 x 1.5 x 9 ……………………………………………… 6

2 x 1.5 x 6.5 ……………………………………………… 6

2 x 1.5 x 9 ………………………………………………… 7

2.5 x 2 x 6.5S ……………………………………………… 7

2.5 x 2 x 6.5L ……………………………………………… 8

2.5 x 2 x 9S ……………………………………………… 8

2.5 x 2 x 9L ……………………………………………… 9

3 x 2 x 6.5S ……………………………………………… 9

3 x 2 x 6.5L ………………………………………………10

3 x 2 x 9 ……………………………………………………10

3 x 2 x 10 …………………………………………………11

3 x 2.5 x 9 …………………………………………………11

4 x 3 x 6.5 …………………………………………………12

4 x 3 x 9 ……………………………………………………12

1450 rpm – 50 HZ pump CurveS

1.5 x 1.5 x 9 ………………………………………………13

2 x 1.5 x 6.5 ………………………………………………13

2 x 1.5 x 9 …………………………………………………14

2.5 x 2 x 6.5S ………………………………………………14

2.5 x 2 x 6.5L ………………………………………………15

2.5 x 2 x 9S ………………………………………………15

2.5 x 2 x 9L ………………………………………………16

3 x 2 x 6.5S ………………………………………………16

3 x 2 x 6.5L ………………………………………………17

3 x 2 x 9 ……………………………………………………17

3 x 2 x 10 …………………………………………………18

3 x 2 x 11 …………………………………………………18

3 x 2.5 x 9 …………………………………………………19

3 x 2.5 x 11 ………………………………………………19

3 x 2.5 x 13 ………………………………………………20

4 x 3 x 6.5 …………………………………………………20

4 x 3 x 9 ……………………………………………………21

4 x 3 x 11 …………………………………………………21

4 x 3 x 13 …………………………………………………22

4 x 4 x 11 …………………………………………………22

6 x 4 x 9 ……………………………………………………23

6 x 4 x 13 …………………………………………………23

6 x 6 x 9.5 …………………………………………………24

6 x 6 x 11 …………………………………………………24

6 x 6 x 13S …………………………………………………25

6 x 6 x 13L …………………………………………………25

8 x 6 x 9.5 …………………………………………………26

8 x 6 x 11 …………………………………………………26

10 x 8 x 13 …………………………………………………27

PAGE 2

SERIES A-C 2000 - 50 HzGoulds Water Technology

Page 3: Series A-C 2000 - Xylem Applied Waterdocumentlibrary.xylemappliedwater.com/wp-content/blogs...1450 rPM — 50 Hz PuMP Curves PAGE 27 serIes AC 2000 50 Hz Goulds Water Technology 1)

useFuL PuMP FOrMuLAs

Pressure (PSI) = Head(feet)xSpecificGravity 2.31

Head (feet) = Pressure (PSI) x 2.31 SpecificGravity

Vacuum = DynamicSuctionLift(feet)x.883(in.ofmercury) xSpecificGravity

Horsepower = GPMxHead(feet)xSpecificGravity(brake) 3960xPumpEffieciency

Horsepower = GPMxHead(feet)xSpecificGravity(water) 3960

Efficiency = Horsepower (water) x 100 per cent(pump) Horsepower (brake)

NPSH = Positive Factors – Negative Factors(available)

AFFINITY LAWs: effect of change of speed or impeller diameter on centrifugal pumps

GPM Capacity Feet Head BHP

impeller diameter Change Q2 = D2 Q1 D1

H2 = D2 2 H1

D1P2 = D2 3

P1 D1

Speed Change Q2 = RPM2 Q1 RPM1

H2 = RPM2 2 H1

RPM1P2 = RPM2 3

P1 RPM1

Where Q = GPM, H = Head, P = BHP, D = Impeller Diameter, RPM = Pump Speed

(

( (

()

) )

)

PAGE 3

SERIES A-C 2000 - 50 HzGoulds Water Technology

Page 4: Series A-C 2000 - Xylem Applied Waterdocumentlibrary.xylemappliedwater.com/wp-content/blogs...1450 rPM — 50 Hz PuMP Curves PAGE 27 serIes AC 2000 50 Hz Goulds Water Technology 1)

110060 20080 400 500 1000 2000

CAPACITY US GPM405 20 2500 3500 5000150010

20

60

TOTA

L H

EA

D IN

FE

ET

OF

WA

TER

1450 RPM

40

80

200

100

10

2

3

4

5

6

8

5860.1

55

62 65

73

70

67

59

6864

60

69

74

75

71

72.1

77

76.1

6163

68

52

5153

56

57

54

78

79

1

20

60

10060 20080 400 600 1000 2000800

CAPACITY US GPM

TOTA

L H

EA

D IN

FE

ET

OF

WA

TER

2900 RPM

40

80

200

100

400

300

4020

10

52

5153

54

56

58

57 6060.1

55

59

6266

65

50 Hz FuLL HYdrAuLIC rANGe Curves

PAGE 4

SERIES A-C 2000 - 50 HzGoulds Water Technology

Page 5: Series A-C 2000 - Xylem Applied Waterdocumentlibrary.xylemappliedwater.com/wp-content/blogs...1450 rPM — 50 Hz PuMP Curves PAGE 27 serIes AC 2000 50 Hz Goulds Water Technology 1)

Key No.

Pump size and Type

51 1.5x1.5x9

52 2x1.5x6.5

53 2x1.5x9

54 2.5x2x6.5S

55 2.5x2x6.5L

56 2.5x2x9S

57 2.5x2x9L

Key No.

Pump size and Type

51 1.5x1.5x9

52 2x1.5x6.5

53 2x1.5x9

54 2.5x2x6.5L

55 2.5x2x6.5S

56 2.5x2x9L

57 2.5x2x9S

58 3x2x6.5L

59 3x2x6.5S

60 3x2x9

60.1 3x2x10

61 3x2x11

62 3x2.5x9

63 3x2.5x11

64 3x2.5x13

Key No.

Pump size and Type

58 3x2x6.5S

59 3x2x6.5L

60 3x2x9

60.1 3x2x10

62 3x2.5x9

65 4x3x6.5

66 4x3x9

Key No.

Pump size and Type

65 4x3x6.5

66 4x3x9

67 4x3x11

68 4x3x13

69 4x4x11

70 6x4x9

71 6x4x13

72.1 6x6x9.5

73 6x6x11

74 6x6x13S

75 6x6x13L

76.1 8x6x9.5

77 8x6x11

78 8x6x13

79 10x8x13

1450 rPM seLeCTION CHArT

2900 rPM seLeCTION CHArT

PAGE 5

SERIES A-C 2000 - 50 HzGoulds Water Technology

Page 6: Series A-C 2000 - Xylem Applied Waterdocumentlibrary.xylemappliedwater.com/wp-content/blogs...1450 rPM — 50 Hz PuMP Curves PAGE 27 serIes AC 2000 50 Hz Goulds Water Technology 1)

2900 rPM — 50 Hz PuMP Curves

PAGE 6

SERIES A-C 2000 - 50 HzGoulds Water Technology

Page 7: Series A-C 2000 - Xylem Applied Waterdocumentlibrary.xylemappliedwater.com/wp-content/blogs...1450 rPM — 50 Hz PuMP Curves PAGE 27 serIes AC 2000 50 Hz Goulds Water Technology 1)

2900 rPM — 50 Hz PuMP Curves

PAGE 7

SERIES A-C 2000 - 50 HzGoulds Water Technology

Page 8: Series A-C 2000 - Xylem Applied Waterdocumentlibrary.xylemappliedwater.com/wp-content/blogs...1450 rPM — 50 Hz PuMP Curves PAGE 27 serIes AC 2000 50 Hz Goulds Water Technology 1)

2900 rPM — 50 Hz PuMP Curves

PAGE 8

SERIES A-C 2000 - 50 HzGoulds Water Technology

Page 9: Series A-C 2000 - Xylem Applied Waterdocumentlibrary.xylemappliedwater.com/wp-content/blogs...1450 rPM — 50 Hz PuMP Curves PAGE 27 serIes AC 2000 50 Hz Goulds Water Technology 1)

2900 rPM — 50 Hz PuMP Curves

PAGE 9

SERIES A-C 2000 - 50 HzGoulds Water Technology

Page 10: Series A-C 2000 - Xylem Applied Waterdocumentlibrary.xylemappliedwater.com/wp-content/blogs...1450 rPM — 50 Hz PuMP Curves PAGE 27 serIes AC 2000 50 Hz Goulds Water Technology 1)

2900 rPM — 50 Hz PuMP Curves

PAGE 10

SERIES A-C 2000 - 50 HzGoulds Water Technology

Page 11: Series A-C 2000 - Xylem Applied Waterdocumentlibrary.xylemappliedwater.com/wp-content/blogs...1450 rPM — 50 Hz PuMP Curves PAGE 27 serIes AC 2000 50 Hz Goulds Water Technology 1)

2900 rPM — 50 Hz PuMP Curves

PAGE 11

SERIES A-C 2000 - 50 HzGoulds Water Technology

Page 12: Series A-C 2000 - Xylem Applied Waterdocumentlibrary.xylemappliedwater.com/wp-content/blogs...1450 rPM — 50 Hz PuMP Curves PAGE 27 serIes AC 2000 50 Hz Goulds Water Technology 1)

2900 rPM — 50 Hz PuMP Curves

PAGE 12

SERIES A-C 2000 - 50 HzGoulds Water Technology

Page 13: Series A-C 2000 - Xylem Applied Waterdocumentlibrary.xylemappliedwater.com/wp-content/blogs...1450 rPM — 50 Hz PuMP Curves PAGE 27 serIes AC 2000 50 Hz Goulds Water Technology 1)

1450 rPM — 50 Hz PuMP Curves

PAGE 13

SERIES A-C 2000 - 50 HzGoulds Water Technology

Page 14: Series A-C 2000 - Xylem Applied Waterdocumentlibrary.xylemappliedwater.com/wp-content/blogs...1450 rPM — 50 Hz PuMP Curves PAGE 27 serIes AC 2000 50 Hz Goulds Water Technology 1)

1450 rPM — 50 Hz PuMP Curves

PAGE 14

SERIES A-C 2000 - 50 HzGoulds Water Technology

Page 15: Series A-C 2000 - Xylem Applied Waterdocumentlibrary.xylemappliedwater.com/wp-content/blogs...1450 rPM — 50 Hz PuMP Curves PAGE 27 serIes AC 2000 50 Hz Goulds Water Technology 1)

1450 rPM — 50 Hz PuMP Curves

PAGE 15

SERIES A-C 2000 - 50 HzGoulds Water Technology

Page 16: Series A-C 2000 - Xylem Applied Waterdocumentlibrary.xylemappliedwater.com/wp-content/blogs...1450 rPM — 50 Hz PuMP Curves PAGE 27 serIes AC 2000 50 Hz Goulds Water Technology 1)

1450 rPM — 50 Hz PuMP Curves

PAGE 16

SERIES A-C 2000 - 50 HzGoulds Water Technology

Page 17: Series A-C 2000 - Xylem Applied Waterdocumentlibrary.xylemappliedwater.com/wp-content/blogs...1450 rPM — 50 Hz PuMP Curves PAGE 27 serIes AC 2000 50 Hz Goulds Water Technology 1)

1450 rPM — 50 Hz PuMP Curves

PAGE 17

SERIES A-C 2000 - 50 HzGoulds Water Technology

Page 18: Series A-C 2000 - Xylem Applied Waterdocumentlibrary.xylemappliedwater.com/wp-content/blogs...1450 rPM — 50 Hz PuMP Curves PAGE 27 serIes AC 2000 50 Hz Goulds Water Technology 1)

1450 rPM — 50 Hz PuMP Curves

PAGE 18

SERIES A-C 2000 - 50 HzGoulds Water Technology

Page 19: Series A-C 2000 - Xylem Applied Waterdocumentlibrary.xylemappliedwater.com/wp-content/blogs...1450 rPM — 50 Hz PuMP Curves PAGE 27 serIes AC 2000 50 Hz Goulds Water Technology 1)

1450 rPM — 50 Hz PuMP Curves

PAGE 19

SERIES A-C 2000 - 50 HzGoulds Water Technology

Page 20: Series A-C 2000 - Xylem Applied Waterdocumentlibrary.xylemappliedwater.com/wp-content/blogs...1450 rPM — 50 Hz PuMP Curves PAGE 27 serIes AC 2000 50 Hz Goulds Water Technology 1)

1450 rPM — 50 Hz PuMP Curves

PAGE 20

SERIES A-C 2000 - 50 HzGoulds Water Technology

Page 21: Series A-C 2000 - Xylem Applied Waterdocumentlibrary.xylemappliedwater.com/wp-content/blogs...1450 rPM — 50 Hz PuMP Curves PAGE 27 serIes AC 2000 50 Hz Goulds Water Technology 1)

1450 rPM — 50 Hz PuMP Curves

PAGE 21

SERIES A-C 2000 - 50 HzGoulds Water Technology

Page 22: Series A-C 2000 - Xylem Applied Waterdocumentlibrary.xylemappliedwater.com/wp-content/blogs...1450 rPM — 50 Hz PuMP Curves PAGE 27 serIes AC 2000 50 Hz Goulds Water Technology 1)

1450 rPM — 50 Hz PuMP Curves

PAGE 22

SERIES A-C 2000 - 50 HzGoulds Water Technology

Page 23: Series A-C 2000 - Xylem Applied Waterdocumentlibrary.xylemappliedwater.com/wp-content/blogs...1450 rPM — 50 Hz PuMP Curves PAGE 27 serIes AC 2000 50 Hz Goulds Water Technology 1)

1450 rPM — 50 Hz PuMP Curves

PAGE 23

SERIES A-C 2000 - 50 HzGoulds Water Technology

Page 24: Series A-C 2000 - Xylem Applied Waterdocumentlibrary.xylemappliedwater.com/wp-content/blogs...1450 rPM — 50 Hz PuMP Curves PAGE 27 serIes AC 2000 50 Hz Goulds Water Technology 1)

1450 rPM — 50 Hz PuMP Curves

PAGE 24

SERIES A-C 2000 - 50 HzGoulds Water Technology

Page 25: Series A-C 2000 - Xylem Applied Waterdocumentlibrary.xylemappliedwater.com/wp-content/blogs...1450 rPM — 50 Hz PuMP Curves PAGE 27 serIes AC 2000 50 Hz Goulds Water Technology 1)

1450 rPM — 50 Hz PuMP Curves

PAGE 25

SERIES A-C 2000 - 50 HzGoulds Water Technology

Page 26: Series A-C 2000 - Xylem Applied Waterdocumentlibrary.xylemappliedwater.com/wp-content/blogs...1450 rPM — 50 Hz PuMP Curves PAGE 27 serIes AC 2000 50 Hz Goulds Water Technology 1)

1450 rPM — 50 Hz PuMP Curves

PAGE 26

SERIES A-C 2000 - 50 HzGoulds Water Technology

Page 27: Series A-C 2000 - Xylem Applied Waterdocumentlibrary.xylemappliedwater.com/wp-content/blogs...1450 rPM — 50 Hz PuMP Curves PAGE 27 serIes AC 2000 50 Hz Goulds Water Technology 1)

1450 rPM — 50 Hz PuMP Curves

PAGE 27

SERIES A-C 2000 - 50 HzGoulds Water Technology

Page 28: Series A-C 2000 - Xylem Applied Waterdocumentlibrary.xylemappliedwater.com/wp-content/blogs...1450 rPM — 50 Hz PuMP Curves PAGE 27 serIes AC 2000 50 Hz Goulds Water Technology 1)

1) the tissue in plants that brings water upward from the roots;2) a leading global water technology company.

We’re12,500peopleunifiedinacommonpurpose:creatinginnovativesolutionsto meet our world’s water needs. Developing new technologies that will improvethewaywaterisused,conserved,andre-usedinthefutureiscentraltoourwork.Wemove,treat,analyze,andreturnwatertotheenvironment,andwehelppeopleusewaterefficiently,intheirhomes,buildings,factoriesandfarms.Inmorethan150countries,wehavestrong,long-standingrelationshipswithcustomerswhoknow us for our powerful combination of leading product brands and applicationsexpertise,backedbyalegacyofinnovation.

For more information on how Xylem can help you, go to www.xyleminc.com

Xylem

Goulds is a registered trademark of Goulds Pumps, Inc. and is used under license.

©2013XylemInc.CAC200050R1June2014

Xylem inc.

2881 east Bayard Street ext., Suite A Seneca Falls, nY 13148 phone: (800) 453-6777 Fax: (888) 322-5877www.gouldswatertechnology.com