separation of co in coal fired power plants without
TRANSCRIPT
![Page 1: Separation of CO in Coal Fired Power Plants without](https://reader031.vdocuments.us/reader031/viewer/2022012519/6193b24577d64f4df15c2dcd/html5/thumbnails/1.jpg)
Institut für Wärme- undInstitut für Wärme und Brennstofftechnik
Separation of CO2 in Coal Fired Power Plants without Efficiency Losses?!
Reinhard Leithner; Martin Strelow; Silvia Magda; Fridolin Röder; Christian Schlitzberger
![Page 2: Separation of CO in Coal Fired Power Plants without](https://reader031.vdocuments.us/reader031/viewer/2022012519/6193b24577d64f4df15c2dcd/html5/thumbnails/2.jpg)
CO2 capture
CO2 N2+H2OH2O-condensationH2O
CO2
combustion toCO +H O+N
conventional cycles like steam cycle andcombined steam and gas turbine cycle
Gas separation
with MEA,Lithiumzirkonate etc.
CO2-separationN2-separationN2
CO2+H2O+N2
air CmHn
Gas separationmethods:absorptioncryogenicmembraneadsorptioncondensation
gasification methods:
airO2water
exo-therm
(water vapour)gasification
CO
(I)
air separation
O2CO+H 2
condensation watervapourCO2H2
endo-therm recyclingcombined
in solidoxide
fuell cell
N2
CO2-separation CO2
H2
oxidation Fuel cells and adapted conventional cycles like steam
oxygen-combustion
H2O
CO2+H2O
(capable of H2 and CO)
adapted(flue gas recirculation)
conventional cycleslike steam cycle and
bi d t d
CO+H2 - ShiftreactionCO+H2+H2O CO2 + 2H2
(I)
H2O+N2
cycle and combined steam- and gasturbine cycle
H2Ocondensation
H2OCO2
combined steam andgas turbine cycle
22.06.2011| R. Leithner | Separation of CO2 in Coal Fired Power Plants without Efficiency Losses?! | Seite 2
2 2 2 2
![Page 3: Separation of CO in Coal Fired Power Plants without](https://reader031.vdocuments.us/reader031/viewer/2022012519/6193b24577d64f4df15c2dcd/html5/thumbnails/3.jpg)
Principle of Carbonate Looping
RCaOCO2 CaCO3 RH (p0,T0 )
RH (p0,T0 ) 170 kJmol
with mol
- Calcinator:Heat input with high temperatureHeat input with high temperature
- Carbonator:Heat output with lower temperaturep p
- Heat output in Calcinator is equal to heat input in Carbonator
22.06.2011| R. Leithner | Separation of CO2 in Coal Fired Power Plants without Efficiency Losses?! | Seite 3
![Page 4: Separation of CO in Coal Fired Power Plants without](https://reader031.vdocuments.us/reader031/viewer/2022012519/6193b24577d64f4df15c2dcd/html5/thumbnails/4.jpg)
Carbonate Looping as retrofit
- Calcination with oxyfuel-combustion for heat inputrefer to [Epple,2007] TU Darmstadt
- Problem: Air separation and additional fuel necessary
22.06.2011| R. Leithner | Separation of CO2 in Coal Fired Power Plants without Efficiency Losses?! | Seite 4
![Page 5: Separation of CO in Coal Fired Power Plants without](https://reader031.vdocuments.us/reader031/viewer/2022012519/6193b24577d64f4df15c2dcd/html5/thumbnails/5.jpg)
Alternative integration of Carbonate Looping in a coal fired power plant
- Water vapour as fluidisation gas in Calcinator
- Calcinator is integrated in b ti h bcombustion chamber
- Pressure in Calcinator is higher than atmospherehigher than atmosphere downstream turbine for additional power output
- No additional heat input necessary
- Heat transfer for evaporation in Carbonator
22.06.2011| R. Leithner | Separation of CO2 in Coal Fired Power Plants without Efficiency Losses?! | Seite 5
![Page 6: Separation of CO in Coal Fired Power Plants without](https://reader031.vdocuments.us/reader031/viewer/2022012519/6193b24577d64f4df15c2dcd/html5/thumbnails/6.jpg)
Simulation with ENBIRPO (energy balance program)
22.06.2011| R. Leithner | Separation of CO2 in Coal Fired Power Plants without Efficiency Losses?! | Seite 6
![Page 7: Separation of CO in Coal Fired Power Plants without](https://reader031.vdocuments.us/reader031/viewer/2022012519/6193b24577d64f4df15c2dcd/html5/thumbnails/7.jpg)
Modelling of Carbonator and Calcinator
M b lMass balance:
Energy balance:
min,gas min,solid mout,gas mout,solid
Energy balance:Hin,gas Hin,solid Qreaction Hout,gas Hout,solid
- Balance equations in Carbonator and CalcinatorBalance equations in Carbonator and Calcinator- Ideal stirred reactor model (zero dimensional model, temperature in reactor
is equal to output temperature)- Reaction with chemical equilibriumReaction with chemical equilibrium - Equilibrium composition with Gibbs Enthalpy and law of mass action
22.06.2011| R. Leithner | Separation of CO2 in Coal Fired Power Plants without Efficiency Losses?! | Seite 7
![Page 8: Separation of CO in Coal Fired Power Plants without](https://reader031.vdocuments.us/reader031/viewer/2022012519/6193b24577d64f4df15c2dcd/html5/thumbnails/8.jpg)
The reference power plant
- Power plant Staudinger 6 (E.ON Engeneering GmbH)
22.06.2011| R. Leithner | Separation of CO2 in Coal Fired Power Plants without Efficiency Losses?! | Seite 8
![Page 9: Separation of CO in Coal Fired Power Plants without](https://reader031.vdocuments.us/reader031/viewer/2022012519/6193b24577d64f4df15c2dcd/html5/thumbnails/9.jpg)
The reference power plant
22.06.2011| R. Leithner | Separation of CO2 in Coal Fired Power Plants without Efficiency Losses?! | Seite 9
![Page 10: Separation of CO in Coal Fired Power Plants without](https://reader031.vdocuments.us/reader031/viewer/2022012519/6193b24577d64f4df15c2dcd/html5/thumbnails/10.jpg)
Power plant with CO2 capture
22.06.2011| R. Leithner | Separation of CO2 in Coal Fired Power Plants without Efficiency Losses?! | Seite 10
![Page 11: Separation of CO in Coal Fired Power Plants without](https://reader031.vdocuments.us/reader031/viewer/2022012519/6193b24577d64f4df15c2dcd/html5/thumbnails/11.jpg)
Power plant with CO2 capture and compression
22.06.2011| R. Leithner | Separation of CO2 in Coal Fired Power Plants without Efficiency Losses?! | Seite 11
![Page 12: Separation of CO in Coal Fired Power Plants without](https://reader031.vdocuments.us/reader031/viewer/2022012519/6193b24577d64f4df15c2dcd/html5/thumbnails/12.jpg)
Simulation results – QT diagram
Fl CO d H OFlue gas CO2 and H2O downstream Calcinator
22.06.2011| R. Leithner | Separation of CO2 in Coal Fired Power Plants without Efficiency Losses?! | Seite 12
![Page 13: Separation of CO in Coal Fired Power Plants without](https://reader031.vdocuments.us/reader031/viewer/2022012519/6193b24577d64f4df15c2dcd/html5/thumbnails/13.jpg)
Simulation results
Reference power plant
Power plant with CO2 capture
Power plant with CO2capture and p p 2 p pcompression
Heat input 2363 MW 2363 MW 2363 MWHeat input 2363 MW 2363 MW 2363 MW
Steam turbine: electrical output 1101 MW 1040 MW 1040 MW
H O/CO t biH2O/CO2-turbine: electrical output - 41 MW 41 MW
CO2 compression - - 81 MW
Auxiliary power 48 MW 50 MW 50 MW
Gross efficiency 46,6 % 45,8 % 45,8 %
Net efficiency 44,5 % 43,7 % 40,2 %
22.06.2011| R. Leithner | Separation of CO2 in Coal Fired Power Plants without Efficiency Losses?! | Seite 13
![Page 14: Separation of CO in Coal Fired Power Plants without](https://reader031.vdocuments.us/reader031/viewer/2022012519/6193b24577d64f4df15c2dcd/html5/thumbnails/14.jpg)
Possible further improvements
- Evaporation of transport water partly withEvaporation of transport water partly with bled steam and use of CO2 and steam-heat after turbine for part flow superheating and reheatingp g g
- Increasing transport water flow
- Increasing CO2 partial pressure followed b i i l i ti t tby increasing calcination-temperature
22.06.2011| R. Leithner | Separation of CO2 in Coal Fired Power Plants without Efficiency Losses?! | Seite 14
![Page 15: Separation of CO in Coal Fired Power Plants without](https://reader031.vdocuments.us/reader031/viewer/2022012519/6193b24577d64f4df15c2dcd/html5/thumbnails/15.jpg)
Comparison of some technologies to capture CO2
Post combustion Oxyfuel combustion Pre Post combustion Oxyfuel combustion combustion
Chemical absorbtion(MEA)
Carbonate Looping as retrofit
Integrated Carbonate Looping
Chemical Looping
Oxyfuel with recirculation
IGGC power plant
(MEA) retrofit Looping
State of technology
first pilot plants test facility feasibility
study test facility first pilot plants
first pilot plants
Ti h i h t t l t l t l t di h t tTime horizon short-term long-term long-term long-term medium short-term
Retrofit possible yes yes no no (yes) no
10 8 % 3 % 1% (8 %) 10 %Efficiency Losses without compression
10,8 % 3 % < 1% - (8 %) 10 %
[Korkmaz,2011]Berwertung von Maßnahmen zur Nachrüstung von
Steinkohlekraftwerken mit einer CO2 Rückhaltung
[Epple, 2008] CO2 Capture Based on Chemical Looping and
Carbonate Looping, VGB Power Tech
[Gonschorek, 2006]Entwicklungsstand
des Oxyfuel-Prozesses, Kraftwerktechnisches
Kolloquium
[Ogriseck,2006] Kraftwerke mit
Kohlevergasung, Informationsdienst Kompetenz
in Energieeiner CO2 Rückhaltung, VDI Fortschritts-Berichte
22.06.2011| R. Leithner | Separation of CO2 in Coal Fired Power Plants without Efficiency Losses?! | Seite 15
![Page 16: Separation of CO in Coal Fired Power Plants without](https://reader031.vdocuments.us/reader031/viewer/2022012519/6193b24577d64f4df15c2dcd/html5/thumbnails/16.jpg)
Separation of CO2 in Coal Fired Power Plants without Efficiency Losses?!
Thank you for your attentionThank you for your attention
Prof. Dr. techn. R. LeithnerInstitut of Heat and Fuel Technology
Technische Universität BraunschweigTechnische Universität Braunschweigwww.wbt.ing.tuwww.wbt.ing.tu--bs.debs.de
22.06.2011| R. Leithner | Separation of CO2 in Coal Fired Power Plants without Efficiency Losses?! | Seite 16