sens sensitit 2016 · 2016. 11. 1. · hvac industry product guide sensit® gold g2 multi-function...

10
SENSIT SENSIT 2016 PRODUCT GUIDE 2016 PRODUCT GUIDE HVAC INDUSTRY 1.888.475.5235 [email protected] SENSIT -Direct.com

Upload: others

Post on 09-Oct-2020

3 views

Category:

Documents


0 download

TRANSCRIPT

Page 1: SENS SENSITIT 2016 · 2016. 11. 1. · HVAC INDUSTRY PRODUCT GUIDE SENSIT® GOLD G2 Multi-Function Gas Detector SENSIT® HXG-3 / HXG-3P Gas Leak Detector SENSIT® HXG-2d Gas Leak

SENSITSENSIT2016PRODUCT GUIDE2016PRODUCT GUIDE

HVAC INDUSTRY

[email protected] SENSIT-Direct.com

Page 2: SENS SENSITIT 2016 · 2016. 11. 1. · HVAC INDUSTRY PRODUCT GUIDE SENSIT® GOLD G2 Multi-Function Gas Detector SENSIT® HXG-3 / HXG-3P Gas Leak Detector SENSIT® HXG-2d Gas Leak

The Company:SENSIT Technologies is an ISO 9001:2008 compliant, family-owned business located in Valparaiso, Indiana. Since 1980, we have manufactured gas leak detection products that help protect life and property.

Today, as a result of continuous innovation and commitment to customer satisfaction, the company has grown to become a global supplier to several markets:

•Energy:NaturalandPropaneGasIndustries •EmergencyResponse:FireServices •Industrial:Health,SafetyandMaintenance •Municipal:WaterworksandInfrastructure •ServiceContractors:HVACandPlumbing

The Products:SENSIT gas detection products are best known for quickly and easily locating gas leaks and accurate measurement of toxic gases. Durability and low cost of ownership have added to our product popularity. SENSIT instruments can be found in many forms:

•GasLeakDetection •PersonalGasMonitors •InfrastructureDetection

OurinstrumentsmeetapprovalagencystandardsfromUL,ATEX,andCSA.Virtuallyallofourinstrumentscanbe linked to compliance reportingwith theuseofourSmart-Cal calibrationanddatamanagementsystem.Itisthefinallinkforanytotalinstrumentprogram.

The People:The most important asset we have to offer is our incredible people. Our dedicated team of gas detection experts have centuries of combined experience in product development, production, sales and service. Completecustomersatisfactionisournumberoneobjective:

•Providetheexactproducttomeetyourrequirements •Exceedyourexpectationsforservice •Offerthelowestcostofownershipoverthelifeoftheproduct

The Future:SENSIT Technologies is committed to bringing new and innovative detection products to the global marketplace.

[email protected] SENSIT-Direct.com

Page 3: SENS SENSITIT 2016 · 2016. 11. 1. · HVAC INDUSTRY PRODUCT GUIDE SENSIT® GOLD G2 Multi-Function Gas Detector SENSIT® HXG-3 / HXG-3P Gas Leak Detector SENSIT® HXG-2d Gas Leak

HVAC INDUSTRYPRODUCT GUIDE

SENSIT® GOLD G2 Multi-Function Gas Detector

SENSIT® HXG-3 / HXG-3P Gas Leak Detector

SENSIT® HXG-2d Gas Leak Detector

SENSIT® TKX Gas Leak Detector

SENSIT® CO Carbon Monoxide Analyzer

SENSIT® P100 Single-Gas Personal Monitor

SCAL-100 Calibration Station for SENSIT® P100

[email protected] SENSIT-Direct.com

Page 4: SENS SENSITIT 2016 · 2016. 11. 1. · HVAC INDUSTRY PRODUCT GUIDE SENSIT® GOLD G2 Multi-Function Gas Detector SENSIT® HXG-3 / HXG-3P Gas Leak Detector SENSIT® HXG-2d Gas Leak

PRODUCT SPECIFICATIONSSize: 11.5”x3”x2.32”(29.2x7.6x5.9cm)Weight: 1.2lb.(544g)OperationalTemp: -4to104F(-20to40°C)BatteryLife: Alkaline:Approximately18hrs.Continuous

SENSOR SPECIFICATIONSTYPE RESOLUTION RANGE ACCURACYPPM* 1ppmor10ppm 0-10,000ppm ±10%LEL 0.1%upto2% 0-100%LEL ±10%%NATGAS 0.1% 5-100%GAS ±5%%PROPANE 0.1% 2.2-100%GAS ±5%O2 0.1% 0-25% ±0.2%or10%**CO 1ppm 0-2000ppm ±5ppmor5%**H2S 1ppm 0-100ppm ±2ppmor5%**HCN 1ppm 0-30ppm ±1ppmor5%**

LUERPROBECONNECTOR

SENSORCAP

LEL/PPMSENSOR

INFRAREDCOMMUNICATIONS

GRAPHICDISPLAY

ALARMLEDs

OPERATIONBUTTONS

WATER-RESISTANTHOUSING

FLEXIBLEGOOSENECK

BATTERYCOMPARTMENT

Patented

1. Press Power2. Wait 45 Seconds for Automatic Zeroing3. Begin to Use

TO OPERATE:

The most versatile and user-friendly gas leak detector available today!

Displays Up To4 Gases Simultaneously•LEL(%VolumeandPPMOptional)•Oxygen•CarbonMonoxide•HydrogenSulfide•HydrogenCyanide(Optional)

Selectable Gas Type•Methane(NaturalGas)•Propane

Standard Features•IntrinsicallySafeDesign(Certified)•InternalPump-FastSampling•Digital“Tick”Control-FastLeakLocation•LowestCost,LongLifeSensors•LEDWarningLights•BrightGraphicDisplay•LoudAudibleAlarm•BatteryStrengthIndicator•InternalMemory•ExceptionalWaterProtection

Applications•CombustibleGasLeakDetection•GasLeakSurvey•UndergroundLeakPinpointing•CarbonMonoxideInvestigations•ConfinedSpaceMonitoring•CombustibleGasMeasurements•PipelinePurging•Method21EmissionsTesting•InertGasOperations

Partial List of Gases Sensed•Butane •CarbonMonoxide•Gasoline •HydrogenSulfide•Methane •NaturalGas•Oxygen •Propane

STANDARD KIT•HardCarryingCase•3“C”Batteries•ExtraSensorCapChoiceof2PieceBarHoleProbeorConfinedSpaceProbe

•WristStrap •T10AllenWrench•InstructionManual

SENSIT® GOLD G2

**Whicheverisgreater*PPMOptionalPPMRangesAvailable: 0-2,000ppm, 0-5,000ppm, 0-10,000ppm

4 [email protected] SENSIT-Direct.com

Page 5: SENS SENSITIT 2016 · 2016. 11. 1. · HVAC INDUSTRY PRODUCT GUIDE SENSIT® GOLD G2 Multi-Function Gas Detector SENSIT® HXG-3 / HXG-3P Gas Leak Detector SENSIT® HXG-2d Gas Leak

Patented

SENSOR

BACKLITLCDDISPLAY

WARNINGLEDS

OPERATIONBUTTONS

TICKCONTROL

FLEXIBLEGOOSENECK

BATTERYCOMPARTMENT

1. Press Power2. Wait 45 Seconds for Automatic Zeroing3. Begin to Use

TO OPERATE:

PRODUCT SPECIFICATIONSSize: 11.5”x3”x2.2”(29.21x7.62x5.89cm)Weight: 1.2lb.(0.54kg)OperationalTemp: -4to122F(-20to50°C)BatteryLife: Alkaline:Approximately25hrs.Continuous

SENSOR SPECIFICATIONSTYPE RESOLUTION RANGE ACCURACYPPM* 1or10ppm 0-50,000ppm ±10%LEL 0.1% 0-100%LEL ±10%

*PPMOptional

Displays LEL and PPM readings simultaneously for accurate leak detection and analysis.SENSIT® HXG-3/3P

STANDARD KIT•HardCarryingCase•3“C”Batteries

•WristStrap•InstructionManual

HXG-3 Standard Features•IntrinsicallySafeDesign(Certified)•DisplaysLELandPPM•Audible/VisualAlarms•InfraredDownloading•Long-life,Low-CostSensor•SimpleCalibration

HXG-3P Standard Features•IntrinsicallySafeDesign(Certified)•InternalPump•Water/DustFilter•DisplaysLELandPPM•InfraredDownloading•Long-life,Low-CostSensor•SimpleCalibration

Applications•LocateSmallGasLeaks•AreaMonitoring•GasLeakSurveying•GasLinePurging•Arson/AccelerantDetection

Partial List of Gases Sensed•Acetone•Alcohol•Ammonia•Butane•Gasoline•Halon•Hydrogen

•IndustrialSolvents•JetFuel-2610•EthyleneOxide-2610•LacquerThinner•Methane•NaturalGas•Propane•Refrigerants

[email protected] SENSIT-Direct.com

Page 6: SENS SENSITIT 2016 · 2016. 11. 1. · HVAC INDUSTRY PRODUCT GUIDE SENSIT® GOLD G2 Multi-Function Gas Detector SENSIT® HXG-3 / HXG-3P Gas Leak Detector SENSIT® HXG-2d Gas Leak

PRODUCT SPECIFICATIONSSize: 3.5”x10”x1.6”(8.9x25x4cm)Weight: 1.2lb.(0.544kg)OperationalTemp: -4to104°F(-20to40°C)BatteryLife: Alkaline:Approximately50hrs.Continuous

SENSOR SPECIFICATIONSTYPE RESOLUTION RANGE ACCURACYPPM* 10ppm 0-990ppm ±10%LEL 0.1% 0-100%LEL ±10%

*PPMOptional

Gas leak detector with digital display for accurate measurement of gases.SENSIT® HXG-2d

STANDARD KIT•CarryingPouch•3“C”Batteries•T10AllenWrench•InstructionManual

Standard Features•IntrinsicallySafeDesign•Push-ButtonOperation•FieldCalibration•BacklitDisplay•AdjustableAlarms•Long-life,Low-CostSensor

Applications•LocateSmallGasLeaks•AreaMonitoring•GasLeakSurveying•GasLinePurging•ChemicalDetection•Arson/AccelerantDetection

Partial List of Gases Sensed•Acetone•Alcohol•Ammonia•Butane•EthyleneOxide•Gasoline•Halon•Hydrogen•IndustrialSolvents•JetFuel•LacquerThinner•Methane•NaturalGas•Propane•Refrigerants

The SENSIT® HXG-2dcannotbeusedtocheckforcarbonmonoxide(CO)leakage.

PatentPending

SENSOR

ALARMLED

GRAPHICDISPLAY

OPERATIONBUTTONS

ELECTRONICTICKCONTROL

FLEXIBLEGOOSENECK

BATTERYCOMPARTMENT

1. Press Power2. Wait 45 Seconds for Automatic Zeroing3. Begin to Use

TO OPERATE:

6 [email protected] SENSIT-Direct.com

Page 7: SENS SENSITIT 2016 · 2016. 11. 1. · HVAC INDUSTRY PRODUCT GUIDE SENSIT® GOLD G2 Multi-Function Gas Detector SENSIT® HXG-3 / HXG-3P Gas Leak Detector SENSIT® HXG-2d Gas Leak

PRODUCT SPECIFICATIONSSize: 3.5”x10”x1.6”(8.9x25.4x4cm)Weight: 1.3pounds(0.59kg)OperationalTemp: 0to120°F(-20to50°C)BatteryLife: Alkaline:Approximately30hrs.Continuous

SENSOR SPECIFICATIONSTYPE DETECTION LIMIT RANGEPPM 20ppm 20-50,000

The perfect choice when locating hard to find natural gas or propane gas leaks.SENSIT® TKX

SENSIT® TKX is the ideal choice for the budget conscious.

Standard Features•IntrinsicallySafeDesign•SolidState,LongLifeSensor•AdjustableTickRateSystem•AudibleandVisualIndicators•AlkalineBatteryPowered

Applications•GasPipeLeakDetection•Propane/ButaneBottleChecks•ChemicalDetection•Arson/AccelerantDetection

Partial List of Gases Sensed•Acetone•Alcohol•Ammonia•Butane•EthyleneOxide•Gasoline•Halon•Hydrogen•IndustrialSolvents•JetFuel•LacquerThinner•Methane•NaturalGas•Propane•Refrigerants

STANDARD KIT•CarryingPouch•3“C”Batteries•InstructionManual

SENSOR

ON/OFFSWITCH

SENSINGINDICATOR

TICKADJUSTDIAL

FLEXIBLEGOOSENECK

BATTERYCOMPARTMENT

1. Power On2. Wait 30 Seconds3. Adjust Tick4. Begin to Use

TO OPERATE:

[email protected] SENSIT-Direct.com

Page 8: SENS SENSITIT 2016 · 2016. 11. 1. · HVAC INDUSTRY PRODUCT GUIDE SENSIT® GOLD G2 Multi-Function Gas Detector SENSIT® HXG-3 / HXG-3P Gas Leak Detector SENSIT® HXG-2d Gas Leak

PRODUCT SPECIFICATIONSSize: 3”x10”x2.4”(7.6x25.4x6cm)Weight: 1.1pounds(0.5kg)OperationalTemp: -4to104°F(-20to40°C)BatteryLife: Alkaline:Approximately30hrs.Continuous

SENSOR SPECIFICATIONSTYPE RESOLUTION RANGE ACCURACY

CO 1ppm 0-2,000ppm ±5ppmor5%**

CO“AirFree”* 1ppm 0-5,000ppm ±5ppmor5%**

O2* 0.1% 0-25% ±0.2%or10%**

*OptionalConfiguration **Whicheverisgreater

Use SENSIT® CO for Carbon Monoxide testing in residential and commercial buildings.SENSIT® CO

Withitspowerfulrotarypump,hotairprobeandbrightLCDdisplay,theSENSIT® CO is perfect for testing ambient air and hot gas samples.

Infrared communication allows printing of test resultstoacompactprinter(accessory)orPCsimple and convenient.

Applications•COInvestigations•FlueGasTesting•EquipmentInspection&Testing

Standard Features•InternalPump•FlueProbewithWaterTrap•Audible/VisualAlarms•BacklitLCDDisplay•AutomaticZeroing•FieldCalibration•CalibrationAlerts•MemoryStorage•InfraredDownload•HardCarryingCase

Optional Features

Oxygen Sensing:DisplayOxygenandCOSimultaneously

Air-FreeCOReading:AutomaticallyCalculatesCOBasedonAir-FreeCalculation

STANDARD KIT•HardCarryingCase•3“C”Batteries•FlueProbe•5FootFlexibleTubing •ParticleFilter•WristStrap•InstructionManual

WATER/DIRTFILTER

HOTAIRPROBE

INFRAREDCOMMUNICATIONS

BACKLITLCDDISPLAY

ALARMLEDs

OPERATIONBUTTONS

BATTERYCOMPARTMENT

Patented

1. Press Power2. Wait 45 Seconds for Automatic Zeroing3. Begin to Use

TO OPERATE:

8 [email protected] SENSIT-Direct.com

Page 9: SENS SENSITIT 2016 · 2016. 11. 1. · HVAC INDUSTRY PRODUCT GUIDE SENSIT® GOLD G2 Multi-Function Gas Detector SENSIT® HXG-3 / HXG-3P Gas Leak Detector SENSIT® HXG-2d Gas Leak

PRODUCT SPECIFICATIONSSize: 3.81”x2.31”x0.8”(9.67x5.87x2cm)Weight: 3.6oz.(105g)OperationalTemp: -4to104F(-20to40°C)Humidity: 15-90%RH(Non-condensing)PowerSource: 3.6VLithiumBatteryBatteryLife: 2+Years

SENSOR SPECIFICATIONSTYPE RESOLUTION RANGEO2 0.1% 25%

CO* 1ppm 0-999*

H2S 1ppm 0-100

HCN 0.1ppm 0-30

NO2 0.1ppm 0-20

SO2 0.1ppm 0-20

Single gas personal monitor designed to warn the user of hazardous gases in their working environment.SENSIT® P100

Standard Features•IntrinsicallySafeDesign(Certified)•OneButtonOperation•AudibleAlarm•VisualAlarm•VibrationAlarm•STELandTWAAlarms•AlarmEventMemory•EasyFieldCalibration•2-YearOperation•RefurbishProgramAvailableAfter2-yearsOfOperation•Limited2-YearWarranty(IncludingSensor)•ExtendedWarrantyAvailable•ForusewithSCAL-100TestStations

Available Sensors•HydrogenSulfide(H2S)•HydrogenCyanide(HCN)•Oxygen(O2)•CarbonMonoxide(CO)•NitrogenDioxide(NO2)•SulfurDioxide(SO2)

STANDARD KIT•BeltClip•InstructionManual

ALARMLEDs

SENSOR

SOUNDER

ON/OFF

GRAPHICDISPLAY

ZERO/CALIBRATE

BELTCLIP(ONBACK)

Patented

TO OPERATE:1. Press Power2. Wait 30 Seconds for Automatic Zeroing3. Begin to Use

*CO Extended Display Option:

DetectionRange:0ppm-.2%Volume(2000ppmequivalent)

Resolution:1ppm for 0 – 999ppm01%Volumefor1000ppm–2000ppm

[email protected] SENSIT-Direct.com

Page 10: SENS SENSITIT 2016 · 2016. 11. 1. · HVAC INDUSTRY PRODUCT GUIDE SENSIT® GOLD G2 Multi-Function Gas Detector SENSIT® HXG-3 / HXG-3P Gas Leak Detector SENSIT® HXG-2d Gas Leak

PRODUCT SPECIFICATIONSSize: 6”x6”x1.75”(15.24cmx15.24cmx4.5cm)Weight: 2lb.(0.9kg)OperationalTemp: 40–120F(5to50°C)Max.InletPressure: 20PSIPower: 100-240VAC50/60Hz0.2Ainputwith2VDC0.5Aoutput

SCAL-100All calibrationdata; time, date, sensor andpump performance data is stored in the calibrator for download to your computer. Data management software allows automatic uploading from calibrator, creates compliance reports and alerts selected personnel of overdue or failed calibrations.

Design to Test/CalibrateSENSIT® P100 Monitors•O2•CO•H2S•HCN •NO2•SO2

Standard Features:•Indicatespropergaspressure•Automaticoperation when instrument is installed•Indicationofpassorfail•RJ45intranetconnection•Wallordeskmount•CompatiblewithWindows7andWindowsXPNetwork

SMART-CALTM

Reporting Features:•InstrumentTestPastDue•InstrumentFailureAlerts•MonthlyComplianceReport•SensorPerformanceData•OptionalNetworkingSystem•Compatiblewith:SCal-DTM(Desktop)SCal-NTM(Network)DataManagementSoftware

Available Test Gases*•Oxygen-O2•CarbonMonoxide-CO•HydogenSulfide-H2S•HydrogenCyanide-HCN•NitrogenDioxide-NO2•SulfureDioxide-SO2

*ContactSensitTechnologiesformoreinfo.

SOFTWARE REQUIREMENTS30MBHardDriveSpaceWindows® XPorLaterOperatingSystemMicrosoft® OutlookMicrosoftExcel

LANCONNECTION POWERCONNECTION

IRCOM

GASOUTLET

MOUNTINGPLATE

GASINLET

RETAININGCLIP

Calibrates SENSIT® P100 Single Gas Monitors, stores data and manages instrument testing compliance.

For use with Black P100 Models Only.

10 [email protected] SENSIT-Direct.com