Page 1: See it from every angle.d163axztg8am2h.cloudfront.net/static/doc/73/0d/e9f795139... · 2015. 10. 30. · • dBLess patient chair time — faster measurement capture* • f Q Automatic

®

See it from every angle.

Page 2: See it from every angle.d163axztg8am2h.cloudfront.net/static/doc/73/0d/e9f795139... · 2015. 10. 30. · • dBLess patient chair time — faster measurement capture* • f Q Automatic

Accutome 4SIGHT See It From Every Angle | 2

®

For over 30 years Accutome has built a reputation for high quality, reliable and reasonably priced ophthalmic diagnostic equipment. The addition of the 4Sight combination unit is no exception. Designed with eye care professionals in mind, the 4Sight provides a single solution for ophthalmic diagnostics by combining an A-Scan, B-Scan and Pachymeter in one, easy to use platform.

We realize the demands on today’s busy clinics and designed the 4Sight to meet those needs by delivering a high value product that is accurate and efficient.

High Value Workstation• Single solution for all ophthalmic ultrasound imaging at an affordable price• High quality with industry-leading warranty and service programs• Live help and dependable support for the life of the product

Accuracy• Proprietary signal processing• Industry leading clinical accuracy • Unsurpassed image quality

Efficiency• Single point-of-use technology for all ophthalmic diagnostic imaging needs

in an ergonomic portable package• Intuitive user interface for a rapid and smooth learning curve • Easy data transfer between modalities and higher patient throughput• DICOM℠Worklist compatible

4SigHt...

A single solution for

ophthalmic diagnostics

by combining an

A-Scan, B-Scan and

Pachymeter in one,

easy-to-use platform

PACHYMETERB-SCAN

A-SCAN

FOOTSWITCH

KEYBOARD

INTuITIvEuSER INTERFACE(TOuCHSCREEN)

PROBE HOLDERS

KICKSTAND

MOuSE

Page 3: See it from every angle.d163axztg8am2h.cloudfront.net/static/doc/73/0d/e9f795139... · 2015. 10. 30. · • dBLess patient chair time — faster measurement capture* • f Q Automatic

Accutome 4SIGHT See It From Every Angle | 4

A-SCANthe A-Scan features:• Immersion and contact modes

• Industry leading resolution

• User-friendly interface

• Less patient chair time — faster measurement capture*

• Automatic alignment detection and sclera recognition eliminate marginally aligned scans

• Share information easily — adaptable document transfer via EMR, email or printer

• Modern third and fourth generation formulas including the Hoffer®Q, SRK/T, Holladay, Haigis, SRK II and Binkhorst II as well as new post refractive formulas

• Optimized lens constants for superior surgical outcomes

• Streamline your patient data — patient data is passed between modalities for quicker patient flow Accutome A-Scan Plus

PCB: 12345,78 FW: 1.00

SF: 7.00.01

Printed: 6/6/2015

Facility: ACCUTOME Physician: CANNA, NANCY User: BALDWIN, BOBExam Date: 2/24/2015

Patient: TEST, SUE ID: 222 DOB: 1962.03.04Remark: OD Phakic

Waveform #1

AXL: 25.44 mm ACD: 3.58 mm Lens: 3.97 mm VCD: 17.89 mm2/24/201511:44:26 AMGain: 67 dB

Immersion Auto: (SR-)

05

10 15 20 25 30

AXL ACD Lens VCD 12345

AvgDev

25.44 3.58 3.97 17.8925.46 3.60 3.95 17.9125.45 3.57 3.97 17.9125.45 3.60 3.97 17.8825.46 3.60 3.97 17.8925.45 0.01

3.59 0.01

3.97 0.01

17.90 0.01

IOL Formula: HolladayRx Surgery: No

K1: 43.10 DK2: 43.20 DK Index: 1.3375Target: 0.00 D

AXL: 25.45 mm

AXL Used: Average

daveGroup

IOL A-Const

Hof Q Hol

SRK/T Haig

Target

Emme

aad118.705.37

1.6205.40 1.714 0.400 0.100Power Refr

15.3515.35

14.50 0.55 15.00 0.23 15.50 -0.10* 16.00 -0.42 16.50 -0.76

bbb119.105.61

1.8465.65 1.964 0.400 0.100Power Refr

15.6715.67

14.50 0.74 15.00 0.43 15.50 0.11* 16.00 -0.21 16.50 -0.53

ccc115.803.68

-0.0233.59 -0.097 0.400 0.100Power Refr

13.3013.30

12.50 0.59 13.00 0.22 13.50 -0.15* 14.00 -0.52 14.50 -0.90

ddd119.505.84

2.0735.90 2.214 0.400 0.100Power Refr

16.0016.00

15.00 0.62 15.50 0.31 16.00 0.00* 16.50 -0.31 17.00 -0.63

Phakic Eye TypeMaterial Velocity Lens (mm)AC

LensVC

Aqueous1532Phakic1641 Measured

Vitreous1532OS Phakic

AXL ACD Lens VCD 12345

AvgDev

25.45 3.60 3.97 17.8825.44 3.58 3.97 17.8925.44 3.58 3.97 17.8925.45 3.60 3.97 17.8825.45 3.58 3.99 17.8825.45 0.01

3.59 0.01

3.97 0.01

17.88 0.01

Waveform #5

AXL: 25.45 mm ACD: 3.58 mm Lens: 3.99 mm VCD: 17.88 mm2/24/201511:44:41 AMGain: 67 dB

Immersion Auto: (SR-)

05

10 15 20 25 30IOL Formula: HolladayRx Surgery: No

K1: 43.40 DK2: 43.50 DK Index: 1.3375Target: 0.00 D

AXL: 25.45 mm

AXL Used: Average

daveGroup

IOL A-Const

Hof Q Hol

SRK/T Haig

Target

Emme

aad118.705.37

1.6205.40 1.714 0.400 0.100Power Refr

14.9714.97

14.00 0.62 14.50 0.30 15.00 -0.02* 15.50 -0.34 16.00 -0.67

bbb119.105.61

1.8465.65 1.964 0.400 0.100Power Refr

15.2915.29

14.50 0.49 15.00 0.18 15.50 -0.14* 16.00 -0.46 16.50 -0.78

ccc115.803.68

-0.0233.59 -0.097 0.400 0.100Power Refr

12.9612.96

12.00 0.70 12.50 0.34 13.00 -0.03* 13.50 -0.40 14.00 -0.77

ddd119.505.84

2.0735.90 2.214 0.400 0.100Power Refr

15.6115.61

14.50 0.68 15.00 0.38 15.50 0.07* 16.00 -0.24 16.50 -0.56

Phakic Eye TypeMaterial Velocity Lens (mm)AC

LensVC

Aqueous1532Phakic1641 Measured

Vitreous1532

The A-Scan is the single

most effective solution

for measuring and

calculating all of your

patients and refining

your surgical outcomes.

* When compared to original A-Scan Plus.

Page 4: See it from every angle.d163axztg8am2h.cloudfront.net/static/doc/73/0d/e9f795139... · 2015. 10. 30. · • dBLess patient chair time — faster measurement capture* • f Q Automatic

Accutome 4SIGHT See It From Every Angle | 6

B-SCANthe B-Scan features:• Image is everything — 0.015 mm resolution

is among the highest in the medical industry

• State-of-the-art probe design — sharper, more focused images due to the elimination of signal loss

• Unsurpassed data analysis — contains 12 useful measuring calipers

• “Smooth Zoom” Technology — 2x full image zoom without distortion of real-time or captured scan

• Portable — Use with the 4Sight or any Windows based laptop or PC

• Never Miss an Image — Unlimited film loop recordings

• Share Information Easily — Adaptable document transfer via EMR, email or printer

• Master in Minutes — User-friendly interface makes user manuals and quick start guides unnecessary

The B-Scan Plus’™

proprietary software

combined with unique

probe electronics

makes it the premier,

portable High

Definition B-Scan.

Printed: 6/6/2015

Facility: DAVES EYE Physician: BAGOFDONUTS, JOEY User: TOPNOTCH, SCANNER Exam Date: 2/24/2015

Patient: TEST, DAVE ID: 111 DOB: 1961.11.08 Remark: TESTING ALL MODALITY

Accutome B-Scan ReportSF: 1.00.00 Beta V1.6 SN: XXXXXXXX FW: BscanVersion

Page 5: See it from every angle.d163axztg8am2h.cloudfront.net/static/doc/73/0d/e9f795139... · 2015. 10. 30. · • dBLess patient chair time — faster measurement capture* • f Q Automatic

Accutome 4SIGHT See It From Every Angle | 8

the Pachymeter features:• IOP correction calculation — converts IOP measurements in seconds

• Easy-to-use interface

• Gentle touch probe

• Accuracy +/- 5 microns

• Innovative user interface

• 9 measurement areas per eye

• Increase workflow and efficiency

• Sampling rate of 65 MHz

The 4Sight pachymeter

has Digital Signal

Analysis, which offers

outstanding accuracy

and repeatability.

PACHYMETERPrinted: 6/6/2015

OD

593

593

12

3

4

5

6

7

8

9

Measured IOP : 17.2 mm HgAdjusted IOP : 14.2 mm Hg

Region 11 5712 5953 6034 5955 5966 5967 5918 5939 598

AVG

593

Region 71 5862 5873 5894 5905 5936 5937 5948 5999 606

AVG

593

596586

12

3

4

5

6

7

8

9

Measured IOP : 17.5 mm HgAdjusted IOP : 14.5 mm Hg

Region 11 5992 5903 5984 5935 5936 5947 6008 6019 601

AVG

596

Region 61 5922 5853 5864 5875 5866 5877 5878 5889 582

AVG

586

OS

Facility: DAVES EYE Physician: User: Exam Date: 2/24/2015 Patient: TEST, DAVE ID: 111

DOB: 1961.11.08 Remark:

Accutome Pachymetry Report SF: 1.00.00 Beta V1.6 SN: XXXXXXXX FW: 1.00

Page 6: See it from every angle.d163axztg8am2h.cloudfront.net/static/doc/73/0d/e9f795139... · 2015. 10. 30. · • dBLess patient chair time — faster measurement capture* • f Q Automatic

Accutome 4SIGHT See It From Every Angle | 10

11”

specsA-SCAN MODULE

4Sight Specifications

PACHYMEtER MODULE4SigHt UNit

ACCESSORiES

B-SCAN MODULE• Weight: 6 oz.• Dimensions 7”L x 1.25”W• Axial Resolution: 0.015 mm (electronic)• Lateral Resolution: 0.085 mm

(electronic)• Frequency: 12 MHz or 15 MHz• Sampling Rate: 2048• Scan Angle: 60°

• Gamma Linear, S-Curve, Log, Color• Time gain control• 2x optical zoom• Report/Image export PDF, JPEG,

PNG, GIF, TIFF, BITMAP• 256 scans per frame• 12 measuring calipers (6 lines, 2

areas, 2 angles, 2 arrows)

• Weight: 0.08 oz.• Dimensions: 1.75”L x 0.2”W• Electronic Resolution: 0.016 mm• Clinical Accuracy: 0.1 mm• Frequency: 10MHz• Immersion or contact

measurement mode• Default eye types Phakic, Dense

Cataract, Silicone Filled, Pseudo Acrylic/PMMA/Silicone, Aphakic

• Custom eye types possible

• Measurements ACD, lens thickness, VCD, axial length

• Capture modes auto or manual• Data points per waveform 4096• IOL Formulas Hoffer Q, Holladay I,

SRK II, SRK/T, Binkhorst II, Haigis, Clinical History, Contact Lens, Shammas Clinical, Entered

• Report/Image export PDF, JPEG, PNG, GIF, TIFF, BITMAP

• Wireless mouse• Wireless keyboard• Probe holders (on the back of the unit)• Power supply• A-Scan immersion shell• Manual• Quick reference guide• Test blocks (A-Scan and

Pachymeter)

• Foot switch• Optional Accessories - Original B-Scan table top

probe holder - Ergotron mounting arm (for wall

and table mounting)

• Weight: 5 lbs.• Dimensions: 15”W x 2”D x 11”H• Touch screen• Integrated DICOM worklist modality• External connections HDMI and

ethernet

• 5 USB ports• A-Scan probe connection• Pachymeter probe connection

• Weight: 0.67 oz.• Dimensions: 1.75”L x 0.2”W• Accuracy: ±5μ

• Sample Rate: 65 MHz• Measurement Range: 300-999 μ• Automated IOP adjustment

6’