seal maxidepth series - maxiled lighting... · impact protection: ik10 ik10 ik10 thermal protection...

8
MaxiDEPTH Series 102 / 302 / 502 DMX controllable Data over Power distribution to the fixtures MaxiSEAL SEAL DATA Over POWER 2 Core Data over Power DMX RGBW Controllable IP68 IK10

Upload: others

Post on 24-May-2020

16 views

Category:

Documents


0 download

TRANSCRIPT

Page 1: SEAL MaxiDEPTH Series - MaxiLED lighting... · Impact Protection: IK10 IK10 IK10 Thermal Protection cut out at 70ºC: YES YES YES Operation Temperature: -25 to +50 -25 to +50 -25

MaxiDEPTH Series102 / 302 / 502 DMX controllable

Data over Power distributionto the fixtures

MaxiSEAL

SEAL

SEALDATAOver

POWER

2 CoreData over Power

6030

90

DMX RGBWControllable

IP68 IK10

Page 2: SEAL MaxiDEPTH Series - MaxiLED lighting... · Impact Protection: IK10 IK10 IK10 Thermal Protection cut out at 70ºC: YES YES YES Operation Temperature: -25 to +50 -25 to +50 -25

MaxiDEPTH Series 102 / 302 / 502DMX controllable MaxiDEPTH - Datasheet

KEY FEATURES• MaxiSEAL (Fountains, Ponds, Coastal and Marina installation)

• IP68 (Depth 1 Meter)

• 48VAC Data over Power 2 wire system

• 512 DMX RGBW Controllable

• NO DMX connections needed under water

• Recessed, flush or wall mount options

• Surface or Underwater product

Our IP68 MaxiDEPTH fitting is available in 3 different sizes delivering different light outputs, available in clear lens this makes the MaxiDEPTH family of fittings a perfect solution for fountains, ponds, coastal, marina and corrosive environments. Manufactured from quality materials with a MaxiSEAL finish and incorporating our Patented 2 wire data over power technology giving full DMX 512 control down the 2 power wires makes it the simplest to install and most cost effective product of its type in the market place today.

Specifications 102 302 502Dimming DMX512 Dimmable (Data Over power): YES YES YESDMX 512 refresh rate: 44hz 44hz 44hz

LED Options(Cree XQE Led’s) RGBW: YES YES YES(Cree XQE Led’s) RGBWW: YES YES YESIntelligent white 2700k-6000K: YES YES YES

Beam Angles 15/25/40/170 (no optic) YES YES YESToughened Clear Glass Lens: YES YES YES

Electrical specificationPower input: 48VAC Data Over Power MaxiLINK systemLED Current: 200ma 200ma 200maWatts per unit: 4.8w 14.4w 24wMax. Units per system 14 AWG (1.5mm sq) cable: 50 16 10Max distance from 1st to last unit 14 AWG (1.5mm sq) cable: 100m 100m 100mLumens RGBW Clear Glass (Full On): 150 450 750Lumens Intelligent white (Full On): 250 750 1250Lumen Maintenance 85%: 90,000Hrs 90,000Hrs 90,000Hrs

System Cable DistancesMax. 14 AWG (1.5mm sq) cablefrom MaxiLINK to 1st fitting: 15m 15m 15mMax.10 AWG (2.5mm sq) cable from MaxiLINK to 1st fitting: 75m 75m 75m

ProtectionIP68 (Depth 1 Meter) YES YES YESImpact Protection: IK10 IK10 IK10Thermal Protection cut out at 70ºC: YES YES YESOperation Temperature: -25 to +50 -25 to +50 -25 to +50

FinishesMaxiSEAL Black: YES YES YESMaxiSEAL Silver: YES YES YES

Fitting OptionsAdjustable wall bracket: YES YES YESFlush mounting plate: YES YES YESRecessed Sleeve: YES YES YES

Listings: CE

Dimensions & WeightsDiameter (mm): 60 125 156Depth (mm): 85 85 85Weight KG: 0.4KG 1KG 3.4KG

ProductOverview

MaxiLED LightingUnit 2, Farrington Place, Rossendale Road Ind. Est. Burnley, Lancashire. UK. BB11 5TY

T: +44 (0)845 8732 601 E:[email protected]:www.maxiledlighting.com

UK Designed andManufactured

UK MANUFACTURED

MaxiDEPTH 102

MaxiDEPTH 302

MaxiDEPTH 502

Page 3: SEAL MaxiDEPTH Series - MaxiLED lighting... · Impact Protection: IK10 IK10 IK10 Thermal Protection cut out at 70ºC: YES YES YES Operation Temperature: -25 to +50 -25 to +50 -25

MaxiLED LightingUnit 2, Farrington Place, Rossendale Road Ind. Est. Burnley, Lancashire. UK. BB11 5TY

T: +44 (0)845 8732 601 E:[email protected]:www.maxiledlighting.com

MaxiDEPTH Series 102 / 302 / 502Mounting options

This product must be installed by a qualified electrician in accordance withall national and local electrical and construction codes.

Failure to comply with the installation instructions can result in serious injury or death.

FlushWallMountingoptions

AdjustableWallbracketoptions

Recessedsleeve

1

2

3

Flush Mounting plate (front) Flush Mounting plate (wall side)

Adustable Wall bracket

Recessed sleeve Recessed sleeve 302 with fititng

MaxiDEPTH 302 final view

MaxiDEPTH 302 final view

Page 4: SEAL MaxiDEPTH Series - MaxiLED lighting... · Impact Protection: IK10 IK10 IK10 Thermal Protection cut out at 70ºC: YES YES YES Operation Temperature: -25 to +50 -25 to +50 -25

MaxiLED LightingUnit 2, Farrington Place, Rossendale Road Ind. Est. Burnley, Lancashire. UK. BB11 5TY

T: +44 (0)845 8732 601 E:[email protected]:www.maxiledlighting.com

MaxiDEPTH Series 102 / 302 / 502Wiring Illustration

This product must be installed by a qualified electrician in accordance withall national and local electrical and construction codes.

Failure to comply with the installation instructions can result in serious injury or death.

MaxiLED Wiring using Junction box

NOT TO SCALE

CL 8 Jan 2018

1.01.0

1.0 CL8/1/18 MaxiLED Wiring using J. Box

KEYSymbol Description

Scale @:

MaxiLINK Wiring illustration

MaxiDEPTH 102 = MAX 50 Fittings

MaxiDEPTH 502 = MAX 10 FittingsMaxiDEPTH 302 = MAX 16 Fittings

MAX=100M (328ft)

PSU - 48VUL Approved

Controller

MaxiLINK

DMX input

Junction Boxby others

Junction Boxby others

UL Approved

Data+

Neutral 48V Live

Junction Boxby others

Neutral Live

Data- Earth

NeutralLiveEarth

Data -Data +

1 2 3 4 50

1 2 3 4 101 2 3 4 16

MaxiLED Wiring using Junction box

NOT TO SCALE

CL 8 Jan 2018

1.01.0

1.0 CL8/1/18 MaxiLED Wiring using J. Box

KEYSymbol Description

Scale @:

MaxiLINK Wiring illustration

MaxiDEPTH 102 = MAX 50 Fittings

MaxiDEPTH 502 = MAX 10 FittingsMaxiDEPTH 302 = MAX 16 Fittings

MAX=100M (328ft)

PSU - 48VUL Approved

Controller

MaxiLINK

DMX input

Junction Boxby others

Junction Boxby others

UL Approved

Data+

Neutral 48V Live

Junction Boxby others

Neutral Live

Data- Earth

NeutralLiveEarth

Data -Data +

1 2 3 4 50

1 2 3 4 101 2 3 4 16MaxiLED Wiring using Junction box

NOT TO SCALE

CL 8 Jan 2018

1.01.0

1.0 CL8/1/18 MaxiLED Wiring using J. Box

KEYSymbol Description

Scale @:

MaxiLINK Wiring illustration

MaxiDEPTH 102 = MAX 50 Fittings

MaxiDEPTH 502 = MAX 10 FittingsMaxiDEPTH 302 = MAX 16 Fittings

MAX=100M (328ft)

PSU - 48VUL Approved

Controller

MaxiLINK

DMX input

Junction Boxby others

Junction Boxby others

UL Approved

Data+

Neutral 48V Live

Junction Boxby others

Neutral Live

Data- Earth

NeutralLiveEarth

Data -Data +

1 2 3 4 50

1 2 3 4 101 2 3 4 16MaxiLED Wiring using Junction box

NOT TO SCALE

CL 8 Jan 2018

1.01.0

1.0 CL8/1/18 MaxiLED Wiring using J. Box

KEYSymbol Description

Scale @:

MaxiLINK Wiring illustration

MaxiDEPTH 102 = MAX 50 Fittings

MaxiDEPTH 502 = MAX 10 FittingsMaxiDEPTH 302 = MAX 16 Fittings

MAX=100M (328ft)

PSU - 48VUL Approved

Controller

MaxiLINK

DMX input

Junction Boxby others

Junction Boxby others

UL Approved

Data+

Neutral 48V Live

Junction Boxby others

Neutral Live

Data- Earth

NeutralLiveEarth

Data -Data +

1 2 3 4 50

1 2 3 4 101 2 3 4 16

MaxiLED Wiring using Junction box

NOT TO SCALE

CL 8 Jan 2018

1.01.0

1.0 CL8/1/18 MaxiLED Wiring using J. Box

KEYSymbol Description

Scale @:

MaxiLINK Wiring illustration

MaxiDEPTH 102 = MAX 50 Fittings

MaxiDEPTH 502 = MAX 10 FittingsMaxiDEPTH 302 = MAX 16 Fittings

MAX=100M (328ft)

PSU - 48VUL Approved

Controller

MaxiLINK

DMX input

Junction Boxby others

Junction Boxby others

UL Approved

Data+

Neutral 48V Live

Junction Boxby others

Neutral Live

Data- Earth

NeutralLiveEarth

Data -Data +

1 2 3 4 50

1 2 3 4 101 2 3 4 16

MaxiDEPTH 102 / 302 / 502Maximum run distance

102MaximumRunlength

302MaximumRunlength

502MaximumRunlength

Page 5: SEAL MaxiDEPTH Series - MaxiLED lighting... · Impact Protection: IK10 IK10 IK10 Thermal Protection cut out at 70ºC: YES YES YES Operation Temperature: -25 to +50 -25 to +50 -25

MaxiLED LightingUnit 2, Farrington Place, Rossendale Road Ind. Est. Burnley, Lancashire. UK. BB11 5TY

T: +44 (0)845 8732 601 E:[email protected]:www.maxiledlighting.com

MaxiDEPTH Series 102Photometrics - RGBW

RGBW40º-TestperformedonasingleMaxiDEPTH102withclearlensandfullRGBWon

RGBW25º-TestperformedonasingleMaxiDEPTH102withclearlensandfullRGBWon

RGBW15º-TestperformedonasingleMaxiDEPTH102withclearlensandfullRGBWon

RGBWNooptics-TestperformedonasingleMaxiDEPTH102withclearlensandfullRGBWon

Page 6: SEAL MaxiDEPTH Series - MaxiLED lighting... · Impact Protection: IK10 IK10 IK10 Thermal Protection cut out at 70ºC: YES YES YES Operation Temperature: -25 to +50 -25 to +50 -25

MaxiLED LightingUnit 2, Farrington Place, Rossendale Road Ind. Est. Burnley, Lancashire. UK. BB11 5TY

T: +44 (0)845 8732 601 E:[email protected]:www.maxiledlighting.com

MaxiDEPTH Series 102Photometrics - Intelligent white (2700k, 6000K)

Intelligentwhite40º-TestperformedonasingleMaxiDEPTH102withclearlensandfullLEDon

Intelligentwhite25º-TestperformedonasingleMaxiDEPTH102withclearlensandfullLEDon

Intelligentwhite15º-TestperformedonasingleMaxiDEPTH102withclearlensandfullLEDon

IntelligentwhiteNooptics-TestperformedonasingleMaxiDEPTH102withclearlensandfullLEDon

Page 7: SEAL MaxiDEPTH Series - MaxiLED lighting... · Impact Protection: IK10 IK10 IK10 Thermal Protection cut out at 70ºC: YES YES YES Operation Temperature: -25 to +50 -25 to +50 -25

MaxiLED LightingUnit 2, Farrington Place, Rossendale Road Ind. Est. Burnley, Lancashire. UK. BB11 5TY

T: +44 (0)845 8732 601 E:[email protected]:www.maxiledlighting.com

MaxiDEPTH Series 102 / 302 / 502Order codes

Product LED Optic Housing Finish Other

MaxiDEPTH 102 MD102 RGBWW(2700K) 15º 15 Adjustable wall bracket AWB MaxiSEAL Black MSB End of line resistor ELRMaxiDEPTH 302 MD302 RGBCW(6500K) 25º 25 Flush mounting plate FMP MaxiSEAL Silver MSSMaxiDEPTH 502 MD502 IW 40º 40 Recessed sleeve RS 2700 170º 170 3500 6500

EXAMPLE: MD302 3500 40 AWB MSS ELR

Page 8: SEAL MaxiDEPTH Series - MaxiLED lighting... · Impact Protection: IK10 IK10 IK10 Thermal Protection cut out at 70ºC: YES YES YES Operation Temperature: -25 to +50 -25 to +50 -25

Global Distributors

Unit 2, Farrington Place, Rossendale Road Ind. Est. Burnley, Lancashire. UK. BB11 5TYT: +44 (0)845 8732 601

E:[email protected]:www.maxiledlighting.com

North America:VLT

T: +1 949 581 9398E: [email protected]: www.vltcorp.com

MENA/GCC Region(Including Turkey & Turkic Republics)

Lightitude

M +971 04 5588674E: [email protected]

W: www.lightitude.com

United Kingdom:LITE Ltd.

D: +44 (0)1592 757 202M +44 (0)7866 724625E: [email protected]

W: www.lite-ltd.co.uk

Singapore:Technolite

T: +65 6453 1978E: [email protected]

W: www.technolite.global

Ireland:Fantasy Lights

T: +353 1 460 1052M: +353 87 927 3566

E: [email protected]: www.fantasylightsgroup.ie

South Africa:SSLI - Solid State Lighting

M: +27(0)82 785 3890E: [email protected]

W: www.ssli.co.za

New Zealand:Energy Light Ltd.T: +64 3 977 2034

E: [email protected]: www.energylight.net

Netherlands:Q CAT Lighting

T: +31 (0) 10 415 18 11E: [email protected]: www.qcat.nl

Australia:Light Project Pty ltd.T: +61 3 8415 1970F: +61 3 8415 1973

E: [email protected]: www.lightproject.com.au

Sweden:Sweden Stockholm Lighting

T: +46 721 470 087SMS: +46 709 909 110

E: [email protected]