sda – shot data analysis

21
October 2002 Jean Slaughter SDA – Shot Data Analysis Outline •Description of SDA •Examples •Plans for 2003 SDA is a system for acquiring and analy data from stores. It is complementary studies and the data loggers. Version 10-15-02-1

Upload: bell

Post on 24-Jan-2016

44 views

Category:

Documents


0 download

DESCRIPTION

SDA – Shot Data Analysis. Outline Description of SDA Examples Plans for 2003. SDA is a system for acquiring and analyzing data from stores. It is complementary to special studies and the data loggers. Version 10-15-02-1. Schematic View of SDA. SDAEdit. Instruments Other Devices. - PowerPoint PPT Presentation

TRANSCRIPT

Page 1: SDA – Shot Data Analysis

October 2002Jean Slaughter

SDA – Shot Data Analysis

Outline

•Description of SDA

•Examples

•Plans for 2003

SDA is a system for acquiring and analyzing data from stores. It is complementary to specialstudies and the data loggers.

Version 10-15-02-1

Page 2: SDA – Shot Data Analysis

October 2002Jean Slaughter

Schematic View of SDA

InstrumentsOther Devices

System of DA engines

Database

FilesEXCEL,

etc.Scalar, Plot

Viewers

User Programs(Java classes)

Servlets

Standard Plots, Tables,Store Checker

SDAEdit

Page 3: SDA – Shot Data Analysis

October 2002Jean Slaughter

Inputs to SDA• Longitudinal, transverse emittances• Intensities, DC and bunched• Beam positions • Settings

– Magnets, collimators, etc.– Tunes, chromaticities

• Computed devices• Data from CDF, D0

– Luminosity– Losses– Beam position, size

Page 4: SDA – Shot Data Analysis

October 2002Jean Slaughter

Tevatron HEP Collider State Diagram

Proton Inject’nporch

Proton Injectiontune up

Inject Protons

Eject Protons

Inject Pbars

PbarInjection

porch

BeforeRamp

Flattop

Acceleration

Squeeze InitiateCollisions

Remove Halo

HEP

Pause HEP

ProtonRemoval

Unsqueeze

Deceleration

Extractionporch

Extract Pbars

Cogging

Recovery

Ramping

Flattop2

Reset

Cases and Sets

36 sets p injection9 sets for pbar injectionset every 10 min - HEP

Not shown are MI, Pbar Source, Recycler States

Page 5: SDA – Shot Data Analysis

October 2002Jean Slaughter

SDA Viewer WindowCase Unstack Pbars- Store 1843

Page 6: SDA – Shot Data Analysis

October 2002Jean Slaughter

Pbar Bunch Intensities in MI before Transfer Case Inject Pbars - Store 1787

set number (transfer)

bunch intensity - 109

Page 7: SDA – Shot Data Analysis

October 2002Jean Slaughter

MI Bunch Intensities After RF Compensation - Store 1836

Intensity 109

store:set (transfer)

Page 8: SDA – Shot Data Analysis

October 2002Jean Slaughter

Snapshots and Fast Time Plots Capture High Frequency Data- (PlotViewer)

RF cavity phase, RF4 Cavity Volts

RF4 MI phase error, 53 MHZ

246 12 180 seconds

Accumulator RF During Unstacking

Page 9: SDA – Shot Data Analysis

October 2002Jean Slaughter

Standard Plot for Pbar Intensities

Page 10: SDA – Shot Data Analysis

October 2002Jean Slaughter

Store Checker• Purpose

– Monitor instrumentation and DAQ

– Monitor accelerator performance

• Checks SDA data for specified cases/sets

– Min < device value < max

– Min < ( difference in time of 2 devices ) < max

– Min < ( difference in value of 2 devices) < max

• Jobs run automatically every store

• “Standard” and “private” lists

• Results on WWW for “standard” list

• Lists on WWW

Page 11: SDA – Shot Data Analysis

October 2002Jean Slaughter

Store Checker Results

When MiniBoone started running, errors were detected. B:CHGB had to be sampled and held at aa different time.

Page 12: SDA – Shot Data Analysis

October 2002Jean Slaughter

Examples of User Analyses

• Emittances for stores 1300-1700• Calculated versus measured luminosity at CDF• Measured HEP pbar lifetime compared to lifetime

expected from interactions

Page 13: SDA – Shot Data Analysis

October 2002Jean Slaughter

User Analysis Combining Many Stores

P. Derwent

Page 14: SDA – Shot Data Analysis

October 2002Jean Slaughter

Measured Versus Computed Luminosity

P. Lebrun

Page 15: SDA – Shot Data Analysis

October 2002Jean Slaughter

Measured Pbar Lifetime Versus Lifetime Due to Collisions - March

-5 0 5 10 15 20 25 30 35 40

20

30

40

50

60

70

80

90

100

110

120

130

140

150

160

assuming 70 mb X-section

Old Stores (Febr. , March 02)

Comparison between Measured Pbar lifetime and "burn rate" due to collision

Pb

ar

Lie

time

, HE

P (

ho

urs

)

Bunch Number

Life-1036 BurnRate-1036 Life-1043 BurnRate-1043

P. Lebrun

Page 16: SDA – Shot Data Analysis

October 2002Jean Slaughter

-5 0 5 10 15 20 25 30 35 400

20

40

60

80

100

120

140

160

Pb

ar

Lie

time

, HE

P (

ho

urs

)

assuming 70 mb X-section

Recent Stores (Oct 02)

Comparison between Measured Pbar lifetime and "burn rate" due to collision

Bunch Number

Life-1832 BurnRate-1832 Life-1836 BurnRate-1836

Measured Pbar Lifetime Versus Lifetime Due to Collisions - October

P. Lebrun

Page 17: SDA – Shot Data Analysis

October 2002Jean Slaughter

Jobs for 2003• Finish and then maintain SDA infrastructure

– Still some DAQ errors – More flexible user access to data– Physics classes in Java tool kit

• Finish reviewing inputs • Study instrumentation• Standard plots and tables

• Emittances• Automated shots log• Automated summary spreadsheets

• User requests and education• Long term archiving of (non-SDA) data logger data

Page 18: SDA – Shot Data Analysis

October 2002Jean Slaughter

Ongoing Operations in 2003

• Dedicated analyses• Monitoring of SDA inputs

– Instrumentation problems– DAQ problems

• Monitoring of stores– Assimilating all the information– Group of physicists to review data and

follow up on what’s found

Page 19: SDA – Shot Data Analysis

October 2002Jean Slaughter

SDA Team

• Controls Department– K. Cahill, B. Hendricks, M. McCusker, T.

Bolshakov• Computing Division

– P. Lebrun, S. Panacek, A. Kulyavtsev, N. Kouropatkine, R. Rechenmacher

• Systems Departments– E. Harms, J. Annala, D. Capista

• Headquarters– M. Church, J. Slaughter

Page 20: SDA – Shot Data Analysis

October 2002Jean Slaughter

Summary

• SDA infrastructure should be complete in 6 months

• Shot analysis is a continuing part of operations

Page 21: SDA – Shot Data Analysis

October 2002Jean Slaughter

Two Types of Data

• Lumberjack data– Fixed frequencies,

i.e. non-triggered– Used for studies– Circular buffers –

data is overwritten after 1-30 days

– Any user can modify any archive configuration

• SDA data– Triggered at

specific events– Only during stores– Permanent archive– Standard content

Backup Slide