schedule of circuit details for the installation …
TRANSCRIPT
SCHEDULE OF CIRCUIT DETAILS FOR THE INSTALLATION 110091804-Master
Board Details
TO BE COMPLETED IN EVERY CASE ONLY TO BE COMPLETED IF THE DISTRIBUTION BOARD IS NOT CONNECTED DIRECTLY TO THE ORIGIN OF THE INSTALLATION
Location of Distribution Board
Level 2 Dimmer Room Adjacent Goods Lift. Dimmer Rack.
Distribution D B 1 | i g h t s
board 3
designation
Supply to distribution SubMains(SSB 5, 15/TP) board is from:
No of phases 3 Nominal Voltage 400 V
Overcurrent protective device for the distribution circuit
Type B S ( E N ) 88-2 Fuse HRC Ra^g 100 A
Associated RCD (if any)
BS(EN) N/A
RCD No of Poles
RCD Rating
N/A
N/A mA
Circuit Details
ber
ai c
ce m
etho
d 3rve
d
Circuit "a c HP o
Overcurrent protective device
RCD S in
t nu
m
phas
<
Circuit designation
of w
iri
ce m
etho
d ints
Si
conductors csa
lerm
iti
nnec
ti es
(s)
<
ting
Max
imum
pe
rmitt
ed Z
C
ircui
an
d Ty
pe
Ref
eren
No
of p
c
Live m m 2
cpc mm 2
Max
p
disc
o tim
BS(EN) AFDD Type
Rat
ing
Sho
rt c
capa
city
O
pera
cu
rren
t Max
imum
pe
rmitt
ed Z
1/L1 Sub Mains(DB 1 Lights/1L1) G E 1
10 10 5 60898 MCB C 40 10 N/A 0.44
1/L2 Sub Mains(DB 1 Lights /1L2) G E 1
10 10 5 60898 MCB C 40 10 N/A 0.44
1/L3 Sub Mains(DB 1 Lights /1L3) G E 1
10 10 5 60898 MCB C 40 10 N/A 0.44
2/L1 Sub Mains(DB 1 Lights/2L1) G E 1
10 10 5 60898 MCB C 40 10 N/A 0.44
2/L2 Sub Mains{DB 1 Lights /2L2) G E 1
10 10 5 60898 MCB C 40 10 N/A 0.44
2/L3 Sub Mains(DB 1 Lights /2L3) G E 1
10 10 5 60898 MCB c 40 10 N/A 0.44
3/L1 Touch screen supply local O E 1
1.5 1.5 0.4 60898 MCB B 10 10 N/A 3.49
3/L2 Em lights exhibition area RHS O E 1
1.5 1.5 0.4 60898 MCB B 10 10 N/A 3.49
3/L3 Em lights exhibition area LHS O E 2 1.5 1.5 0.4 60898 MCB B 10 10 N/A 3.49
4/L1 Lights staircase 11 O E 3 1.5 1.5 0.4 60898 MCB B 10 10 N/A 3.49
4/L2 Lights local A E 1 2.5 1.5 0.4 60898 MCB B 10 10 N/A 3.49
4/L3 SPARE - - - - - - - - - - - - -
5/TP SPARE - - - - - - - - - - - - -
6/TP SPARE - - - - - - - - - - - -
7/TP SPARE - - - - - - - - - - - -
srrp SPARE - - - - - - - - - - - - -
9fTP SPARE - - - - - - - • - - - - -
10/L1 Socket & FCU above DB G E 1 2.5 2.5 0.4 61009 RCD/RCBO c 16 10 30 1.09
10/L2 SPARE - - - - - - - - - - -. -
10/L3 Sub Mains(DB 1 Lights /10L3) G E 1 10 10 5 60898 MCB c 32 10 N/A 0.54
11/TP SPARE - - - - - - - - - - - - -
12/TP SPARE - - - - - - - - - - - - -
13/TP SPARE - - - - - - - - - - - -
14/TP SPARE - - - - - • • - • - - •
Wiring Code
A B c D E F G H 0
PVC cables FVC cables FVC cables FVC cables PVC/FVC in in in in PVC/SWA XLPeSWA Mineral insulated O f h e i r
cables metallic non-metallic metallic non-metallic cables cables cables winer conduit conduit trunking trunking
Copyright © Trimble 2018, FastTest Pro V2018.0.1, PHS Page 183 of 264
SCHEDULE OF CIRCUIT DETAILS FOR THE INSTALLATION 110091804-Master
Board Details
TO BE COMPLETED IN EVERY CASE ONLY TO BE COMPLETED IF THE DISTRIBUTION BOARD IS NOT CONNECTED DIRECTLY TO THE ORIGIN OF THE INSTALLATION
Location of Distribution Board
Distribution board designation
Level 2 Dimmer Room Adjacent Goods Lift. Dimmer Rack.
DB 1 lights
Supply to distribution SubMains(SSB 5, 15/TP) board is from:
No of phases 3 Nominal Voltage 400 V
Overcurrent protective device for the distribution circuit
Type BS(EN) 88-2 Fuse HRC Rating 100 A
Associated RCD (if any)
BS(EN) N/A
N/A
RCD Rating N/A
RCD No of Poles
mA
Circuit Details
Circuit designation
SPARE
•B a
Circuit conductors csa
Live cpc
c o s c <» °- o E X o ~ CO CO ~
2 =5
Overcurrent protective device
BS(EN) AFDD Type
RCD
2 c a s»
N E T J
. § 1
Wiring Code
A B C D E F G H 0
PVOFVC cables
FVC cables in
metallic conduit
FVC cables in
non-metallic conduit
PVC cables in
metallic trunking
FVC cables in
non-metallic trunking
PvOSWA cables
XLPHSWA cables
Mineral insulated cables Other
Copyright© Trimble 2018, FastTest Pro V2018.0.1, PHS Page 185 of 264
SCHEDULE OF CIRCUIT DETAILS FOR THE INSTALLATION 110091804- Master
Board Details
TO BE COMPLETED IN EVERY CASE ONLY TO BE COMPLETED IF THE DISTRIBUTION BOARD IS NOT CONNECTED DIRECTLY TO THE ORIGIN OF THE INSTALLATION
Location of Level 2 Dimmer Room Distribution Adjacent Goods Lift. Board J
Dimmer Rack.
Distribution board designation
DB 1 Lights /1L1
Supply to distribution SubMainsfDB 1 lights, 1/L1) board is from:
No of phases 1 Nominal Voltage 400 V
Overcurrent protective device for the distribution circuit
Type BS(EN) 60898 MCB C Rating 40 A
Associated RCD (if any)
BS(EN) N/A
RCD No of Poles
RCD Rating
N/A
N/A mA
Circuit Details
-Q 0) C CO 5 m
b
Circuit designation
Circuit conductors csa
Live cpc
0) g
°- o E X o •$ CO CO
2 '-6
Overcurrent protective device
BS(EN) AFDD Type
w 3
RCD
c ^
s i as O 3 1/L1 Track lights exhibition area 1 1.5 0.4 60898 MCB 10 N/A
SPARE
Track lights exhibition area 2
Track lights exhibition area 3 60898 MCB
9/L1 SPARE
Track lights exhibition area 4
SPARE
10 N/A
Wiring Code
A B c D E F G H 0
pve/Fvc cables
PVC cables in
metallic conduit
FVC cables in
non-metallic conduit
FVC cables in
metallic trunking
PVC cables in
non-metallic trunking
FVC/3/VA cables
XLPEVSiA/A cables
Mineral insulated cables Other
Copyright ©Trimble 2018, FastTest Pro V2018.0.1, PHS Page 187 of 264
SCHEDULE OF CIRCUIT DETAILS FOR THE INSTALLATION 110091804-Master
Board Details
TO BE COMPLETED IN EVERY CASE ONLY TO BE COMPLETED IF THE DISTRIBUTION BOARD IS NOT CONNECTED DIRECTLY TO THE ORIGIN OF THE INSTALLATION
Level 2 Dimmer Room Adjacent Goods Lift.
Supply to distribution SubMains(DB 1 lights, 1/L2)
Associated RCD (if any) Location of Distribution Board
Level 2 Dimmer Room Adjacent Goods Lift.
Supply to distribution SubMains(DB 1 lights, 1/L2)
Associated RCD (if any) Location of Distribution Board
Level 2 Dimmer Room Adjacent Goods Lift. board is from: BS(EN) N/A
Location of Distribution Board
Dimmer Rack. No of phases -| Nominal Voltage 400 V RCD No Of Poles Overcurrent protective device for the distribution circuit RCD No Of Poles N/A
Distribution board designation
DB 1 Lights/1L2 Overcurrent protective device for the distribution circuit
RCD No Of Poles
Distribution board designation Type BS(EN) 60898 MCB C Rating 40 A RCD Rating N/A mA
Circuit Details
Circ
uit
num
ber
and
phas
e
Circuit designation
Type
of w
iring
R
efer
ence
met
hod
No
of p
oint
s se
rved
Circuit conductors csa
Max
per
mitt
ed
disc
onne
ctio
n tim
es (s
)
Overcurrent protective device RCD
Max
imum
pe
rmitt
ed Z
s (Q
) C
ircui
t nu
mbe
r an
d ph
ase
Circuit designation
Type
of w
iring
R
efer
ence
met
hod
No
of p
oint
s se
rved
Circuit conductors csa
Max
per
mitt
ed
disc
onne
ctio
n tim
es (s
)
BS(EN) AFDD Type
Rat
ing
(A)
Sho
rt ci
rcui
t ca
paci
ty (
kA)
Ope
ratin
g cu
rrent
(lA
n)
Max
imum
pe
rmitt
ed Z
s (Q
) C
ircui
t nu
mbe
r an
d ph
ase
Circuit designation
Type
of w
iring
R
efer
ence
met
hod
No
of p
oint
s se
rved
Live m m 2
cpc mm 2
Max
per
mitt
ed
disc
onne
ctio
n tim
es (s
)
BS(EN) AFDD Type
Rat
ing
(A)
Sho
rt ci
rcui
t ca
paci
ty (
kA)
Ope
ratin
g cu
rrent
(lA
n)
Max
imum
pe
rmitt
ed Z
s (Q
)
1/L2 Track lights exhibition area 5 O E 1 1.5 1.5 0.4 60898 MCB c 6 10 N/A 2.91
2/L2 SPARE - - - - - - - - - - -
3/L2 SPARE - - - - - - - - - - -
4/L2 Track lights exhibition area 6 O E 1 1.5 1.5 0.4 60898 MCB c 6 10 N/A 2.91
5/L2 SPARE - - - - - - - - - - - -
6/L2 SPARE - - - - - - - - - - -
7/L2 Track lights exhibition area 7 0 E 1 1.5 1.5 0.4 60898 MCB c 6 10 N/A 2.91
8/L2 SPARE - - - - - - - - -
9/L2 SPARE - - - - - - - - - - • - -
10/L2 Track lights exhibition area 8 0 E 1 1.5 1.5 0.4 60898 MCB c 6 10 N/A 2.91
11/L2 SPARE - - - - - - - - - - - -
12/L2 SPARE - - - - - - - - - - -
Wiring Code
A B c D E F G H 0
PVCPVC cables
PVCcables in
metallic conduit
PVCcables in
non-metallic conduit
PVCcables in
metallic trunking
PVCcables in
non-metallic trunking
PvUSWA cables
XLPE/SvVA cables
Mineral insulated cables Other
Copyright © Trimble 2018, FastTest Pro V2018.0.1, PHS Page 189 of 264
SCHEDULE OF CIRCUIT DETAILS FOR THE INSTALLATION 110091804-Master
Board Details
TO BE COMPLETED IN EVERY CASE ONLY TO BE COMPLETED IF THE DISTRIBUTION BOARD IS NOT CONNECTED DIRECTLY TO THE ORIGIN OF THE INSTALLATION
Location of Distribution Board
Distribution board designation
Level 2 Dimmer Room Adjacent Goods Lift. Dimmer Rack.
DB 1 Lights/1L3
Supply to distribution SubMains(DB 1 lights, 1/L3) board is from: No of phases 1 Nominal Voltage 400 V
Overcurrent protective device for the distribution circuit
Type BS(EN) 60898 MCB C Rating 40 A
Associated RCD (if any)
BS(EN) N/A
RCD No of Poles
RCD Rating
N/A
N/A mA
Circuit Details
c to
Circuit designation
Circuit conductors csa
Live cpc o E
Overcurrent protective device
BS(EN) AFDD Type o &
RCD
8.2 O 5
1/L3 Track lights exhibition area 9 0.4 60898 MCB N/A
3/L3 SPARE
Track lights exhibition area 10 N/A
5/L3 SPARE
6/L3 SPARE
7/L3 Track tights exhibition area 11
12/L3
Track lights exhibition area 12
SPARE
1.5 1.5 0.4 60898 MCB N/A
Wiring Code
A B c D E F G H 0
pve/r-vc cables
PVCcables in
metallic conduit
PVCcables in
non-metallic conduit
PVCcables in
metallic trunking
PVC cables in
non-metallic trunking
FVOSWA cables
XLPE/9/VA cables
Mineral insulated cables Other
Copyright ©Trimble 2018, FastTest Pro V2018.0.1, PHS Page 191 of 264
SCHEDULE OF CIRCUIT DETAILS FOR THE INSTALLATION 110091804-Master
Board Details
TO BE COMPLETED IN EVERY CASE ONLY TO BE COMPLETED IF THE DISTRIBUTION BOARD IS NOT CONNECTED DIRECTLY TO THE ORIGIN OF THE INSTALLATION
Location of Distribution Board
Distribution board designation
Level 2 Dimmer Room Adjacent Goods Lift. Dimmer Rack.
DB 1 Lights /2L1
Supply to distribution SubMains(DB 1 lights, 2/L1) board is from: No of phases "| Nominal Voltage 400 V
Overcurrent protective device for the distribution circuit
Type BS(EN) 60898 MCB C Ra«ng 40 A
Associated RCD (if any)
BS(EN) N/A
RCD No of Poles
RCD Rating
N/A
N/A mA
Circuit Details
c in
Circuit designation
Circuit conductors csa
Live cpc
T3 C a o e •
ffl I ffl °- o E X o £ CD <0 5 5
Overcurrent protective device
BS(EN) AFDD Type •c o
03 S
RCD
.1 3
Track lights exhibition area 13 1.5 1.5 N/A
Track lights exhibition area 14 N/A
5/L1 SPARE
SPARE
Track lights exhibition area 15 1.5 1.5 0.4
8/L1 SPARE
10/L1 Track lights exhibition area 16
SPARE
Wiring Code
A B c D E F G H 0
PVOPVC cables
PVCcables in
metallic conduit
FVC cables in
non-metallic conduit
PVC cables in
metallic trunking
PVCcables in
non-metallic trunking
FVC/SWA cables
XLPBSWA cables
Mineral insulated cables Other
Copyright © Trimble 2018, FastTest Pro V2018.0.1, PHS Page 193 of 264
SCHEDULE OF CIRCUIT DETAILS FOR THE INSTALLATION 110091804-Master
Board Details
TO BE COMPLETED IN EVERY CASE ONLY TO BE COMPLETED IF THE DISTRIBUTION BOARD IS NOT CONNECTED DIRECTLY TO THE ORIGIN OF THE INSTALLATION
Location of Level 2 Dimmer Room Distribution Adjacent Goods Lift. Board
Dimmer Rack.
Distribution DB 1 Lights /2L2 board a
designation
Supply to distribution SubMains(DB 1 lights, 2/L2) I board is from:
No of phases -| Nominal Voltage 400 V
Overcurrent protective device for the distribution circuit
Type BS(EN) 60898 MCB C Rating 40 A
Associated RCD (if any)
BS(EN) N/A
RCD No of Poles
RCD Rating
N/A
N/A mA
Circuit Details
X I CD F co
Circuit designation
Circuit conductors csa
Live cpc
~o c CD o ~
a o E X O ~ CO CO
2 =5
Overcurrent protective device
BS(EN) AFDD Type •c o
to s
RCD
e c
o 5 o
N E -a
1/L2 Track lights exhibition area 17
SPARE
1.5 1.5
6/L2
7/L2 SPARE
Wiring Code
A B c D E F G H 0
F V a F V C cables
PVCcables in
metallic conduit
PVCcables in
non-metallic conduit
PVCcables in
metallic trunking
PVCcables in
non-metallic trunking
FVOSWA cables
XLPE7SJVA cables
Mineral insulated cables Other
Copyright © Trimble 2018, FastTest Pro V2018.0.1, PHS Page 195 of 264
SCHEDULE OF CIRCUIT DETAILS FOR THE INSTALLATION 110091804- Master
Board Details
TO BE COMPLETED IN EVERY CASE ONLY TO BE COMPLETED IF THE DISTRIBUTION BOARD IS NOT CONNECTED DIRECTLY TO THE ORIGIN OF THE INSTALLATION
Location of Level 2 Dimmer Room Distribution Adjacent Goods Lift. Board
Merlin Gerin.
Distribution board designation
DB 2 Power
Supply to distribution SubMains(SSB 5, 14/TP) board is from:
No of phases 3 Nominal Voltage 400 V
Overcurrent protective device for the distribution circuit
Type BS(EN) 88-2 Fuse HRC Rating 100 A
Associated RCD (if any)
BS(EN) N/A
RCD No of Poles
RCD Rating
Circuit Details
a op c
ce m
etho
d srve
d
Circuit T3 c Overcurrent protective
device RCD S
t num
ph
as
Circuit designation
of w
iri
ce m
etho
d lints
Si
conductors csa
lerm
iti
nnec
ti es
(s)
< o
ting
Max
imum
pe
rmitt
ed Z
. C
ircui
an
d Ty
pe
Ref
eren
o Q.
O O
z
Live m m 2
cpc mm 2
Max
f disc
o tim
BS(EN) AFDD Type
Rat
ing
Sho
rt ci
ca
paci
ty
Ope
ra
curr
ent M
axim
um
perm
itted
Z.
1/L1 Sockets exhibition area near side A B 8 2x2.5 2x1.5 0.4 61009 RCD/RCBO C 32 10 30 0.54
1/L2 Sockets exhibition area centre columns A B 10 2x2.5 2x1.5 0.4 61009 RCD/RCBO c 32 10 30 0.54
1/L3 Sockets far corridor near rear entrance A B 8 2x2.5 2x1.5 0.4 61009 RCD/RCBO c 32 10 30 0.54
2/L1 Sockets exhibition area far columns A B 8 2x2.5 2x1.5 0.4 61009 RCD/RCBO c 32 10 30 0.54
2/L2 Door access control A B 1
2.5 1.5 0.4 60898 MCB B 10 10 N/A 3.49
2/L3 Security supply A B 1
2.5 1.5 0.4 60898 MCB C 20 10 N/A 0.87
3/L1 CCTV supply near A B 1
2.5 1.5 0.4 60898 MCB c 20 10 N/A 0.87
3/L2 CCTV supply far A B 1
2.5 1.5 0.4 60898 MCB c 20 10 N/A 0.87
3/L3 SPARE - - - - - - - - • - - -
4/L1 Fire alarm panel level 3 D B 1
2.5 2.5 0.4 60898 MCB B 10 10 N/A 3.49
4/L2 BMS Supply G E 1
16 16 5 60898 MCB C 63 10 N/A 0.28
4/L3 SPARE - - - - - - - - - - -
5/L1 SPARE - - - - - - - - - - - - -
5/L2 SPARE • - ' - - - - - - - -
5/L3 Compressor room sockets A B 2 2.5 1.5 0.4 61009 RCD/RCBO c 16 10 30 1.09
6/TP Compressor supply G E 1 6 6 0.4 60898 MCB D 20 10 N/A 0.44
7/L1 SPARE - - - - - - - - - - - -
7/L2 SPARE - - - - - - - - - -
7/L3 Contactor supply A B 1 6 2.5 0.4 60898 MCB C 32 10 N/A 0.54
8/L1 SPARE - - - - - - • - - - - -
8/L2 SPARE • - - - - - - - - - - - -
8/L3 Contactor supply A B 1 6 2.5 0.4 60898 MCB c 32 10 N/A 0.54
9/L1 SPARE - - - - - - - - - -
9/L2 SPARE - • • • - - • - -
Wiring Code
A B c D E F G H 0
PVOFVC cables
PVCcables in
metallic conduit
FVC cables in
non-metallic conduit
FVC cables in
metallic trunking
PVCcables in
non-metallic trunking
FVOSWA cables
XLPBSWA cables
Mineral insulated cables Other
Copyright © Trimble 2018, FastTest Pro V2018.0.1, PHS Page 233 of 264
SCHEDULE OF CIRCUIT DETAILS FOR THE INSTALLATION
Board Details
110091804-Master
TO BE COMPLETED IN EVERY CASE ONLY TO BE COMPLETED IF THE DISTRIBUTION BOARD IS NOT CONNECTED DIRECTLY TO THE ORIGIN OF THE INSTALLATION
Location of Distribution Board
Distribution board designation
Level 2 Dimmer Room Adjacent Goods Lift. Merlin Gerin.
DB 2 Power
Supply to distribution SubMains(SSB 5, 14/TP) board is from: No of phases 3 Nominal Voltage 400 V
Overcurrent protective device for the distribution circuit
Type BS(EN) 88-2 Fuse HRC Rating 100 A
Associated RCD (if any)
BS(EN) N/A
RCD No of Poles
RCD Rating
N/A
N/A mA
Circuit Details
Circ
uit n
umbe
r an
d ph
ase
Circuit designation
Type
of w
iring
R
efer
ence
met
hod
No
of p
oint
s se
rved
Circuit conductors csa
Max
per
mitt
ed
disc
onne
ctio
n tim
es (
s)
Overcurrent protective device RCD
Max
imum
pe
rmitt
ed Z
s (fl
) C
ircui
t num
ber
and
phas
e
Circuit designation
Type
of w
iring
R
efer
ence
met
hod
No
of p
oint
s se
rved
Circuit conductors csa
Max
per
mitt
ed
disc
onne
ctio
n tim
es (
s)
BS(EN) AFDD Type
Rat
ing
(A)
Sho
rt ci
rcui
t ca
paci
ty (
kA)
Ope
ratin
g cu
rren
t (lA
n)
Max
imum
pe
rmitt
ed Z
s (fl
) C
ircui
t num
ber
and
phas
e
Circuit designation
Type
of w
iring
R
efer
ence
met
hod
No
of p
oint
s se
rved
Live m m 2
cpc mm 2
Max
per
mitt
ed
disc
onne
ctio
n tim
es (
s)
BS(EN) AFDD Type
Rat
ing
(A)
Sho
rt ci
rcui
t ca
paci
ty (
kA)
Ope
ratin
g cu
rren
t (lA
n)
Max
imum
pe
rmitt
ed Z
s (fl
)
9/L3 Contactor supply A B 1 6 2.5 0.4 60898 MCB C 32 10 N/A 0.54
10/L1 Fan coil ring 1 A E LIM 2x2.5 2x1.5 0.4 60898 MCB B 32 10 N/A 1.09
10/L2 Fan coil ring 2 A E LIM 2x2.5 2x1.5 0.4 60898 MCB B 32 10 N/A 1.09
10/L3 Fan coil ring 3 A E LIM 2x2.5 2x1.5 0.4 60898 MCB B 32 10 N/A 1.09
11/TP AHU local G E 1 4 4 0.4 60898 MCB C 20 10 N/A 0.87
12/TP AHU far G E 1 4 4 0.4 60898 MCB C 20 10 N/A 0.87
Wiring Code
A B c D E F G H 0
FVOFVC cables
PVCcables in
metallic conduit
PVCcables in
non-metallic conduit
FVC cables in
metallic trunking
PVC cables in
non-metallic trunking
PVQSWA cables
XLPESWA cables
Mineral insulated cables Other
Copyright ©Trimble 2018, FastTest Pro v2018.0.1, PHS Page 235 of 264