METROLOGIC INSTRUMENTS, INC.
MS1690 Focus
Area Imaging Bar Code Scanner
Supplemental Configuration Guide
-
8/13/2019 Scanner Codes - QR
2/22
Copyright
2005 by Metrologic Instruments, Inc. All rights reserved. No part of thiswork may be reproduced, transmitted, or stored in any form or by any meanswithout prior written consent, except by reviewer, who may quote briefpassages in a review, or provided for in the Copyright Act of 1976.
Products and brand names mentioned in this document are trademarks oftheir respective companies.
-
8/13/2019 Scanner Codes - QR
3/22
ii
TABLE OF CONTENTS
Scanner OperationPresentation and Trigger Modes........................................................................1
Presentation Mode .........................................................................................1Multi-Try Trigger Mode ...................................................................................1Continuous Trigger Mode...............................................................................1Single Trigger Mode .......................................................................................2
Omnidirectional and/or Linear Scanner Modes..................................................3Linear Illumination Aiming..................................................................................5Data Output........................................................................................................5Same Symbol Timeouts.....................................................................................6
Code Types and Decode RulesData Matrix.........................................................................................................7QR Code ............................................................................................................8MaxiCode ...........................................................................................................8
Aztec ..................................................................................................................9Postal .................................................................................................................9
RS232Software Handshaking.....................................................................................13
InterfacesAdditional Interfaces.........................................................................................14
Office Locations and Contact Information............................................................17
-
8/13/2019 Scanner Codes - QR
4/22
-
8/13/2019 Scanner Codes - QR
5/22
1
SCANNER OPERATION
Presentation and Trigger Modes
The MS1690 has four configurable modes for scanning: the presentation mode,
the multi-try trigger Mode, the continuous trigger mode and the single-triggermode. These modes can be configured separately for in-stand and out-of-standscanner operation.
Presentation ModeOut-of-Stand
* Presentation ModeIn-Stand
4 1 8 3 0 4
4 2 0 2 0 4
* Multi-Try Trigger Mode
Out-of-Stand
Multi-Try Trigger Mode
In-Stand
4 1 8 3 2 4 4 2 0 2 2 4
Continuous Trigger ModeOut-of-Stand
Continuous Trigger ModeIn-Stand
4 1 8 3 5 4 4 2 0 2 5 4
* Factory Default Configuration
-
8/13/2019 Scanner Codes - QR
6/22
2
SCANNER OPERATION
Presentation and Trigger Modes
Single Trigger Mode
Out-of-Stand
Single Trigger Mode
In-Stand
4 1 8 3 4 4 4 2 0 2 4 4
Set In-Stand Mode to MatchOut-of Stand Mode
4 2 0 2 1 5 4
* Factory Default Configuration
-
8/13/2019 Scanner Codes - QR
7/22
3
SCANNER OPERATION
Omnidirectional and/or Linear Scanner Modes
The MS1690 can be configured to operate as an omnidirectional scanner, or a
linear scanner, or a combination of both. The scanner can be configured tothese modes separately for trigger and presentation operations.
When configured to operate as an omnidirectional scanner, all 1D and 2Dbarcodes are scanned omnidirectionally (except Code 128 scanner configurationlabels, which have to be linearly aligned for successful scanning).
When configured to operate as a linear scanner, the 1D barcodes have to belinearly aligned for successful scanning while the 2D barcodes cannot bescanned.
When configured to operate as both the linear and omnidirectional scanner, the1D barcodes have to be linearly aligned for successful scanning while the 2Dbarcodes are scanned omnidirectionally.
By default, the scanner is configured to omnidirectional scanning for trigger andpresentation operations.
Enable Linear Onlyin Trigger Operations
Disable Linear Onlyin Trigger Operations
1 2 0 2 1 3 1 2 0 2 0 3
Enable 1D Linear Onlyin Trigger Operations
Disable 1D Linear Onlyin Trigger Operations
1 2 0 2 1 2 1 2 0 2 0 2
-
8/13/2019 Scanner Codes - QR
8/22
4
SCANNER OPERATION
Omnidirectional and/or Linear Scanner Modes
Enable Linear Only
in Presentation Operations
Disable Linear Only
in Presentation Operations
1 2 0 2 1 1 1 2 0 2 0 1
Enable 1D Linear Onlyin Presentation Operations
Disable 1D Linear Onlyin Presentation Operations
1 2 0 2 1 0 1 2 0 2 0 0
-
8/13/2019 Scanner Codes - QR
9/22
5
SCANNER OPERATION
Linear Illumination Aiming
The MS1690 can be configured to use the linear illumination as an aiming
means, separately for trigger and presentation operations.
* Enable Aiming inTrigger Operations
Disable Aiming inTrigger Operations
1 2 4 0 0 0 1 2 4 0 1 0
Enable Aiming inPresentation Operations
* Disable Aiming inPresentation Operations
1 2 4 0 1 1 1 2 4 0 0 1
Data Output
The MS1690 can be configured to have the data output disabled.
* Enable Data Output Disable Data Output
1 2 1 2 0 5 1 2 1 2 1 5
* Factory Default Configuration
-
8/13/2019 Scanner Codes - QR
10/22
6
SCANNER OPERATION
Same Symbol Timeouts
Retain Same Symbol
Timeout on Trigger
* Reset Same Symbol
Timeout on Trigger
1 2 0 0 1 3
The same-symboltimeout is notrestarted when thetrigger is pulled.
1 2 0 0 0 3 The same-symboltimeout is restartedwhen the trigger ispulled.
* Factory Default Configuration
-
8/13/2019 Scanner Codes - QR
11/22
7
CODE TYPES AND DECODE RULES
Data Matrix
Enable Normal
Color Data Matrix Decoding
Enable Inverse
Color Data Matrix Decoding
2 0 0 5 2 2 2 0 0 5 1 2
Enable Normal andInverseColor Data Matrix Decoding
* DisableData Matrix Decoder
2 0 0 5 3 2 2 0 0 5 0 2
Enable RectangularData Matrix SymbolDecoding
* Disable RectangularData Matrix SymbolDecoding
1 0 0 5 1 1 1 0 0 5 0 1
* Factory Default Configuration
-
8/13/2019 Scanner Codes - QR
12/22
8
CODE TYPES AND DECODE RULES
QR Code
Enable Normal
Video QR Code
Enable Inverse
Video QR Code
2 0 0 6 1 2 2 0 0 6 2 2
Enable Normal andInverseQR Code
* Disable QR Code
2 0 0 6 3 2 2 0 0 6 0 2
MaxiCode
Enable MaxiCode * Disable MaxiCode
1 0 0 6 1 4 1 0 0 6 0 4
* Factory Default Configuration
-
8/13/2019 Scanner Codes - QR
13/22
9
CODE TYPES AND DECODE RULES
Aztec
Enable Normal
Video Aztec Decoding
* Disable Normal
Video Aztec Decoding
1 0 0 6 1 0 1 0 0 6 0 0
Enable InverseVideo Aztec Decoding
* Disable InverseVideo Aztec Decoding
1 0 0 6 1 1 1 0 0 6 0 1
Postal
EnableAustralia Post
* DisableAustralia Post
1 2 6 2 1 7 1 2 6 2 0 7
* Factory Default Configuration
-
8/13/2019 Scanner Codes - QR
14/22
10
CODE TYPES AND DECODE RULES
Postal
Enable Japan Post * Disable Japan Post
1 2 6 2 1 6 1 2 6 2 0 6
Enable KIX Code * Disable KIX Code
1 2 6 2 1 5 1 2 6 2 0 5
EnablePLANET Code
* DisablePLANET Code
1 2 6 2 1 4 1 2 6 2 0 4
* Factory Default Configuration
-
8/13/2019 Scanner Codes - QR
15/22
11
CODE TYPES AND DECODE RULES
Postal
Enable
POSTNET Code
* Disable
POSTNET Post
1 2 6 2 1 3 1 2 6 2 0 3
Enable B & BFielded POSTNET
* Disable B & BFielded POSTNET
1 2 6 2 1 2 1 2 6 2 0 2
EnableUPU Decoding
* DisableUPU Decoding
1 2 6 2 1 1 1 2 6 2 0 1
* Factory Default Configuration
-
8/13/2019 Scanner Codes - QR
16/22
12
CODE TYPES AND DECODE RULES
Postal
Enable
Royal Mail 4 Code
* Disable
Royal Mail 4 Code
1 2 6 2 1 0 1 2 6 2 0 0
* Factory Default Configuration
-
8/13/2019 Scanner Codes - QR
17/22
13
RS232
Software Handshaking
Enable
]V Handshaking
Disable
]V Handshaking
1 2 5 2 1 0
An ]V response fromthe host indicatesreception of scanner data.
1 2 5 2 0 0
-
8/13/2019 Scanner Codes - QR
18/22
14
INTERFACES
Additional Interfaces
Enable Beeper
ON/OFF Commands
* Disable Beeper
ON/OFF Commands
1 2 5 2 1 1
Enables beeper on/offcommands with internalUSB and IBM interfaces.
1 2 5 2 0 1
3rd
GenerationIBM 46xx Defaults
9 9 9 9 5 2 For this feature tofunction properly, scanIBM Reserved Code #2after scanning the 3
rd
Generation IBM 46xxDefault bar code.
IBM Reserved Code #2
3 1 7 2 1 0
Scan IBM Reserve barcode above afterscanning the 3
rd
Generation IBM 46xxDefault bar code.
-
8/13/2019 Scanner Codes - QR
19/22
15
INTERFACES
Additional Interfaces
IBM 46xx-SIOC RS485 Interface
Send 30H for Last BlockLabel Identifier 4680
* Send 00 for Last BlockLabel Identifier 4680
1 1 7 2 1 5
For PDFcodes only.
1 1 7 2 0 5
For PDFcodes only.
IBM-OEM USB Interface
Send 30H for Last BlockLabel Identifier USB
* Send 00 for Last BlockLabel Identifier USB
1 1 6 3 0 0
For PDFcodes only.
1 1 6 3 1 0
For PDFcodes only.
-
8/13/2019 Scanner Codes - QR
20/22
16
INTERFACES
Additional Interfaces
Full Speed USB
Keyboard Interface
9 9 9 9 4 0
-
8/13/2019 Scanner Codes - QR
21/22
-
8/13/2019 Scanner Codes - QR
22/22
April 2005
Printed in the USA
0 0 - 0 2 0 6 5 B