40
SANKOM SANKOM Sp. z o.o. Sp. z o.o. Introduction Introduction SAMKOM is a Polish company developing HVAC CAD SAMKOM is a Polish company developing HVAC CAD software. software. We have been on the software market for 14 years. We have been on the software market for 14 years. We have an We have an o o ffice in Warsaw. ffice in Warsaw. We employ 6 people and outsource to two additional We employ 6 people and outsource to two additional people. people.

Upload: brigit

Post on 11-Jan-2016

54 views

Category:

Documents


0 download

DESCRIPTION

SANKOM Sp. z o.o. Introduction. SAMKOM is a Polish company developing HVAC CAD software. We have been on the software market for 14 years. We have an o ffice in Warsaw. We employ 6 people and outsource to two additional people. The Team of Software Developers. - PowerPoint PPT Presentation

TRANSCRIPT

Page 1: SANKOM Sp. z o.o.  Introduction

SANKOMSANKOM Sp. z o.o. Sp. z o.o. IntroductionIntroduction

• SAMKOM is a Polish company developing HVAC CAD software.SAMKOM is a Polish company developing HVAC CAD software.

• We have been on the software market for 14 years.We have been on the software market for 14 years.

• We have an We have an ooffice in Warsaw.ffice in Warsaw.

• We employ 6 people and outsource to two additional people.We employ 6 people and outsource to two additional people.

Page 2: SANKOM Sp. z o.o.  Introduction

The Team of Software DevelopersThe Team of Software Developers• The main part of our team The main part of our team areare::

1.1. Piotr Wereszczyński MSc Eng. - former employee of Piotr Wereszczyński MSc Eng. - former employee of the the Warsaw University of Warsaw University of Technology - one of the most renowned universities in Poland.Technology - one of the most renowned universities in Poland.

2.2. Michał Strzeszewski PhD Eng. - staff member of Michał Strzeszewski PhD Eng. - staff member of the the Warsaw University of Warsaw University of Technology.Technology.

3.3. Piotr Narowski PhD Eng. - staff member ofPiotr Narowski PhD Eng. - staff member of the the Warsaw University of Technology. Warsaw University of Technology.

• Three additional programmers with good knowledge of HVAC technology.Three additional programmers with good knowledge of HVAC technology.

• One person responsible for program data bases.One person responsible for program data bases.

• Specialisation: heating systems, district heating, ventilation and water supply.Specialisation: heating systems, district heating, ventilation and water supply.

• About 25 years of software developing experience.About 25 years of software developing experience.

• Permanent cooperation with National Energy Conservation Agency, Permanent cooperation with National Energy Conservation Agency, organisation organisation promoting promoting modern solutions in energy auditing and energy modern solutions in energy auditing and energy management.management.

Page 3: SANKOM Sp. z o.o.  Introduction

The Team of Software DevelopersThe Team of Software Developers• Extensive training experience in Polish and English. About Extensive training experience in Polish and English. About 88000 engineers 000 engineers

have taken part in trainings on software applicationhave taken part in trainings on software applicationss so far. so far.

• Over 200 publications on civil and environmental engineering, as well as Over 200 publications on civil and environmental engineering, as well as software related subjects.software related subjects.

• Working knowledge of English, German and Russian.Working knowledge of English, German and Russian.

Page 4: SANKOM Sp. z o.o.  Introduction

Created SoftwareCreated Software• CAD programs for CAD programs for designing designing heating (Audytor OZC and Audytor C.O.) and heating (Audytor OZC and Audytor C.O.) and

interior water supply systems (Audytor H2O).interior water supply systems (Audytor H2O).

• HVAC Engineer's Calculator (Kalkulator Audytora Energetycznego).HVAC Engineer's Calculator (Kalkulator Audytora Energetycznego).

• A prA program for air conditioning process design (Wykres I-X Molliera dla ogram for air conditioning process design (Wykres I-X Molliera dla wilgotnego powietrza)wilgotnego powietrza)

• Air conditioning visualisation module in theAir conditioning visualisation module in the AC system AC system ofof The Polish Security The Polish Security Printing Works.Printing Works.

• A A program for buildingprogram for building dynamic energy analysis.dynamic energy analysis.

Page 5: SANKOM Sp. z o.o.  Introduction

Advantages of SAdvantages of SANKOMANKOM's Software's Software• More than 14 years of experience on the Polish market and more than 10 years More than 14 years of experience on the Polish market and more than 10 years

in the countries of the former Soviet Union.in the countries of the former Soviet Union.

• Programs Audytor OZC and Audytor C.O., as well as programs based on Programs Audytor OZC and Audytor C.O., as well as programs based on them, are the most known and the most often used in Poland and in the them, are the most known and the most often used in Poland and in the countries of the former Soviet Union. Thecountries of the former Soviet Union. Thesese programs are recognised as programs are recognised as ‘‘the the industrial standardindustrial standard’’..

• Very clear and extensive documentation including description Very clear and extensive documentation including description of of individual individual functions, examples and contextual help system.functions, examples and contextual help system.

• Very goodVery good,, full translation of the programs and the documentation in Russian. full translation of the programs and the documentation in Russian. RepresentationRepresentation in Moscow and Kiev (Kan company) with technical support. in Moscow and Kiev (Kan company) with technical support. Technical data (radiators, valves) specific for Russian market.Technical data (radiators, valves) specific for Russian market.

• Simple and intuitional operation. UserSimple and intuitional operation. User--friendly interface.friendly interface.

Page 6: SANKOM Sp. z o.o.  Introduction

Advantages of SANKOM's SoftwareAdvantages of SANKOM's Software• Elegant graphics. Elegant graphics. MultiMulti window environment (two views of the system window environment (two views of the system

drawingdrawing available available).).

• Full DXF and DWG Full DXF and DWG support including importing and exporting with the support including importing and exporting with the layers layoutlayers layout..

• Fast data entering process.Fast data entering process.

• Fast calculation process.Fast calculation process.

• Extensive error diagnostics. Extensive error diagnostics. Complex Complex error and warning messageerror and warning messagess system. system. Fast error Fast error identificationidentification..

• Tested calculation algorithms.Tested calculation algorithms.

• Possibility ofPossibility of designing designing large systems. large systems.

• Efficient technical assistance.Efficient technical assistance.

• High reliability.High reliability.

• Great flexibility.Great flexibility.

Page 7: SANKOM Sp. z o.o.  Introduction

Heat Demand Calculating Program (Audytor OZC)Heat Demand Calculating Program (Audytor OZC)• This program This program calculatescalculates the heat demand for the heat demand for

the individual the individual rooms and the whole building. rooms and the whole building.

• The program operates in accordance with The program operates in accordance with Polish Polish and European and European standards.standards.

• The program calculates:The program calculates:

1.1. Heat transfer coefficient U (k),Heat transfer coefficient U (k),

2.2. Heat demand for separate rooms,Heat demand for separate rooms,

3.3. Heat demand for the whole building,Heat demand for the whole building,

4.4. Heat energy consumHeat energy consumpption for the whole building.tion for the whole building.

• All calculation results can be printed or transferred via clipboard to another All calculation results can be printed or transferred via clipboard to another application. application.

• Calculation results can be automatically transferred to the central heating Calculation results can be automatically transferred to the central heating calculation program Audytor C.O.calculation program Audytor C.O.

Page 8: SANKOM Sp. z o.o.  Introduction

Heating Systems Design Program (Audytor C.O.)Heating Systems Design Program (Audytor C.O.)• A program for designing heating systems, which A program for designing heating systems, which

was created for was created for graphic design of new central graphic design of new central heating systems, as well as hydronic balancing of heating systems, as well as hydronic balancing of already existing ones (e.g. in additionally insulated already existing ones (e.g. in additionally insulated buildings). buildings).

• The program also enables designing systems of The program also enables designing systems of chilled water chilled water systemssystems pipes pipes..

• Systems Systems covered by the program:covered by the program:

1.1. Double- or single-pipe systems (important on East European markets),Double- or single-pipe systems (important on East European markets),

2.2. Upper or bottom heating agent division,Upper or bottom heating agent division,

3.3. Vertical and horizontal (including manifold) systems,Vertical and horizontal (including manifold) systems,

4.4. Convection radiators and unerfloor radiators,Convection radiators and unerfloor radiators,

5.5. Systems with thermostatic radiator valves,Systems with thermostatic radiator valves,

6.6. Systems with balancing stabiliSystems with balancing stabilissers,ers,

7.7. Systems with flow governors.Systems with flow governors.

Page 9: SANKOM Sp. z o.o.  Introduction

Heating Systems Design Program (Audytor C.O.)Heating Systems Design Program (Audytor C.O.)

• Catalogue data base of the program contains infoCatalogue data base of the program contains informationrmation aboutabout pipes, pipes, accessories and radiators produced by leading local and international accessories and radiators produced by leading local and international companies.companies.

• The pThe program enables performing full rogram enables performing full hydraulichydraulic calculations for the system, calculations for the system, including:including:1.1. AdjustAdjustinging pipe diameterspipe diameters,,

2.2. EstimatiEstimatingng hydraulic resistance of loops hydraulic resistance of loops,,

3.3. Providing information about overall pressure Providing information about overall pressure loss in systemloss in system,,

4.4. Reducing oReducing overpressure in loops by adjusting verpressure in loops by adjusting initial presets of valves or selecting aperture initial presets of valves or selecting aperture diameters for balancing orificesdiameters for balancing orifices,,

5.5. AdjustAdjusting ing presets for differential pressure presets for differential pressure governors installed in positions selected bygovernors installed in positions selected by the the designer (riser's base, system's branch, etc.)designer (riser's base, system's branch, etc.),,

6.6. Taking into consideration the requirements Taking into consideration the requirements regarding authorities on thermostatic valves regarding authorities on thermostatic valves (appropriate pressure drop on valves).(appropriate pressure drop on valves).

Page 10: SANKOM Sp. z o.o.  Introduction

Heating Systems Design Program (Audytor C.O.)Heating Systems Design Program (Audytor C.O.)

• Heat calculations performed by the program Heat calculations performed by the program include the following functions:include the following functions:

1.1. Estimation of heat gains from pipes of system led Estimation of heat gains from pipes of system led in individual rooms.in individual rooms.

2.2. Calculation of cooling for heating agent in supply Calculation of cooling for heating agent in supply pipes.pipes.

3.3. Estimation of required radiators' dimensions for Estimation of required radiators' dimensions for given heat load demand.given heat load demand.

4.4. Adjustment of flux of heating agent supplying heat Adjustment of flux of heating agent supplying heat receivers, taking into account its cooling in pipes receivers, taking into account its cooling in pipes and heat gains from pipes (variant of regulation of and heat gains from pipes (variant of regulation of existing system, e.g. in additionally insulated existing system, e.g. in additionally insulated buildings).buildings).

5.5. Influence of water coolingInfluence of water cooling down down in pipes on in pipes on gravity pressure value in individual loops, as well gravity pressure value in individual loops, as well as on heat receivers heat load.as on heat receivers heat load.

6.6. Floor radiators design.Floor radiators design.

Page 11: SANKOM Sp. z o.o.  Introduction

Water Supply Program (Audytor HWater Supply Program (Audytor H22O)O)

• This is a CAD software for graphic design of This is a CAD software for graphic design of interior water supply systems in housing interior water supply systems in housing and public services buildings. and public services buildings.

• CalculationCalculationss are performed according to are performed according to European or Russian standards.European or Russian standards.

• The hydraulic calculations include:The hydraulic calculations include:

1.1. Determination of nominal water flows.Determination of nominal water flows.

2.2. Selection of pipeSelection of pipe diameters.diameters.

3.3. Estimation of hydraulic resistance of system Estimation of hydraulic resistance of system elements.elements.

4.4. Determination of required pressure.Determination of required pressure.

5.5. Adjustment flows in circulation loops by Adjustment flows in circulation loops by appropriate presets on valves or aperture appropriate presets on valves or aperture diameters for balancing orificesdiameters for balancing orifices

Page 12: SANKOM Sp. z o.o.  Introduction

Water Supply Program (Audytor HWater Supply Program (Audytor H22O)O)

• The heat calculations include:The heat calculations include:

1.1. Calculation of required water flow in circulation network Calculation of required water flow in circulation network using using thermal method thermal method (determination of water cooling(determination of water cooling down down in system elements). in system elements).

2.2. Selection of pipe insulation.Selection of pipe insulation.

3.3. Selection of temperature presets on thermostatic valves.Selection of temperature presets on thermostatic valves.

Page 13: SANKOM Sp. z o.o.  Introduction

Catalogue Data BaseCatalogue Data Base

• Catalogue data base of the program contains infoCatalogue data base of the program contains information aboutrmation about pipes, pipes, accessories and radiators produced by leading local and international accessories and radiators produced by leading local and international companies.companies.

• High flexibility of the program enables simultaneous usage of accessories, High flexibility of the program enables simultaneous usage of accessories, pipes and radiators of different producers in one project.pipes and radiators of different producers in one project.

• Over 30 000 radiators, 6 000 valves and 300 pipe types in the Over 30 000 radiators, 6 000 valves and 300 pipe types in the pprogram rogram ddata ata bbasease

Page 14: SANKOM Sp. z o.o.  Introduction

Catalogue Data BaseCatalogue Data Base

• Detailed technical dataDetailed technical data,, very very useful useful forfor designerdesigners.s.

Page 15: SANKOM Sp. z o.o.  Introduction

Catalogue Data BaseCatalogue Data Base

• Indexed Indexed PDFPDF documentation connected to the program documentation connected to the program ddata ata bbase.ase.

Page 16: SANKOM Sp. z o.o.  Introduction

InternetInternet Data Base Data Base

• All products from the program All products from the program ddata ata bbase ase can be foundcan be found on SANKOM’s on SANKOM’s webwebsite at site at www.sankom.pl..

Page 17: SANKOM Sp. z o.o.  Introduction

InternetInternet Data Base Data Base

• PPDFDF documentation documentation is also available on-lineis also available on-line..

Page 18: SANKOM Sp. z o.o.  Introduction

Software downladSoftware downlad

• In case In case the software is licensed under the the software is licensed under the open licenceopen licence,, it it is available on is available on SANKOM’s webSANKOM’s websitesite..

Page 19: SANKOM Sp. z o.o.  Introduction

ReferencesReferencesCompany Poland Russia Czech Rep.Aquapex Aquatherm Brugman Vasco Comap Coprax Danfoss Fraenkische Giacomini Herz Honeywell IDMAR IMI IMMERGAS John Guest Kan KISAN Oventrop Radson PURMO UPONOR Viega Vogel&Noot Wavin

Page 20: SANKOM Sp. z o.o.  Introduction

SANKOMSANKOM C.H. version 3. C.H. version 3.66

GRAPHIC PROGRAM FOR DESIGNING AND GRAPHIC PROGRAM FOR DESIGNING AND HYDRONIC HYDRONIC

BALANCING OF CENTRAL HEATING BALANCING OF CENTRAL HEATING SYSTEMSSYSTEMS

Page 21: SANKOM Sp. z o.o.  Introduction

General program featuresGeneral program features• Graphic design of new central heating systemsGraphic design of new central heating systems..

• HHydronic balancing of already existingydronic balancing of already existing ones.ones.

• DDesigning systems of pipes in esigning systems of pipes in chilled waterchilled water systems systems..

• GraphiGraphicc design of design of underfloorunderfloor heating systems. heating systems.

Page 22: SANKOM Sp. z o.o.  Introduction

CCentral heating system criteriaentral heating system criteria • Pump installationPump installation . .

• Two-pipe Two-pipe and one-pipe and one-pipe systemsystem (very popular in Russia) (very popular in Russia)..

• Upper or bottom division, vertical pipes distribution systems, manifold Upper or bottom division, vertical pipes distribution systems, manifold systemssystems . .

• Convection Convection or or uunderfloor radiatorsnderfloor radiators . .

• Normal or thermostatic radiator valvesNormal or thermostatic radiator valves . .

• Initial regulation Initial regulation with with valves with valves with an an initial preset or orificesinitial preset or orifices . .

• Differential pressure balancing Differential pressure balancing withwith balancing stabilisers balancing stabilisers . .

• Possibility of using flow governorsPossibility of using flow governors ..

• Pump mixing systemsPump mixing systems

Page 23: SANKOM Sp. z o.o.  Introduction

HHydraulic calculationsydraulic calculations • AdjusAdjusting pipe ting pipe diametersdiameters..

• EstimatiEstimatingng hydraulic resistance for individual circuits, taking into account hydraulic resistance for individual circuits, taking into account gravity pressuregravity pressure ( (resulting from water coolingresulting from water cooling down down in pipes and heat in pipes and heat receiversreceivers))..

• ReducReducinging overpressure in circuits by adjusting initial presets of valves with overpressure in circuits by adjusting initial presets of valves with double control, or adjustment of aperture diameters for balancing orificesdouble control, or adjustment of aperture diameters for balancing orifices..

• TakTakinging into account into account the the neneccessity of ensuring essity of ensuring a a relevant hydraulic resistance relevant hydraulic resistance of pipe-run with of pipe-run with the the heat receiver (heat receiver (ppgmingmin))..

• AdjustAdjusting ing presets for differential pressure governors installed in positions presets for differential pressure governors installed in positions selected byselected by the the designer (riser’s base, system’s branch, etc.) designer (riser’s base, system’s branch, etc.)..

• Taking into consideration the requirements regarding authorities of Taking into consideration the requirements regarding authorities of thermostatic valves thermostatic valves (appropriate pressure drop on valves)(appropriate pressure drop on valves)..

Page 24: SANKOM Sp. z o.o.  Introduction

Heat calculationsHeat calculations• EstimatiEstimatingng heat gains from pipes heat gains from pipes installedinstalled in individual rooms in individual rooms..

• CalculatiCalculatingng the the cooling cooling down in pipes down in pipes forfor a a heating agent heating agent..

• EstimatiEstimatingng required radiator dimensions for given heat load demand required radiator dimensions for given heat load demand..

• AdjustAdjustinging appropriate flux of heating agent in appropriate flux of heating agent in flowing heat receiversflowing heat receivers, taking , taking into account its cooling in pipes and heat gains from pipes (variant of into account its cooling in pipes and heat gains from pipes (variant of regulation of existing system, e.g. in additionally insulated buildings)regulation of existing system, e.g. in additionally insulated buildings)..

• TakTakinging into account into account the the influence of water cooling influence of water cooling down down in pipes on in pipes on the the value value of gravity pressure in individual circuits, as well as on of gravity pressure in individual circuits, as well as on the the heat load of heat heat load of heat receiversreceivers..

• DesignDesigninging underfloor radiators underfloor radiators

Page 25: SANKOM Sp. z o.o.  Introduction

Basic dataBasic data

Water temperatures

Heat source parameters

Available pipes

• Includes basic data for Includes basic data for the the whole system.whole system.

• Used Used forfor selecting selecting the calculation range. the calculation range.Catalogue data

Selection of the calculation variant

Page 26: SANKOM Sp. z o.o.  Introduction

Radson OZC

Drawing the system diagramDrawing the system diagramData Data will will be entered inbe entered in a a graphic form into graphic form into the the system diagram. system diagram.

Movable toolbars

Two independently scaled views of the drawing

Drawing toolbar

Categories of edited items

Tables enabling simultaneous editing of many system components

Drawings present in the project

Dynamic link between the table and the drawing

Pull-down buttons

Pull-down list configuration

Page 27: SANKOM Sp. z o.o.  Introduction

Radson OZC

Preparing the system diagram examplePreparing the system diagram example

+ 3.00

Construction tab

Scale selection

Radiators tab

Plate radiators

Pipes tabAccessories tab

KOMPAKT-**600 m

100 %

1Pokój

+20°C 1976/0 W

2Kuchnia

+20°C 429/0 W

dn A1/3

dn A1/4

dn A1/2

V-EXAKT-DTdn

V-EXAKT-DTdn

Room zones

LabelsCeiling

Creation

KOMPAKT-**600 m

100 %

Page 28: SANKOM Sp. z o.o.  Introduction

Radson OZC

UUssing ing ready blocksready blocks

Copying and Blocks tab

Traditional instalations

C**-600 m

100 %

C**-600 m

100 %

1Pokój

+20°C 1976/0 W

2Kuchnia

+20°C 429/0 W

dn A1/3

dn A1/2

dn A1/4

V-EXAKT-DTdn

V-EXAKT-DTdn

+ 3.00

+ 6.00

Copy right

0 m

100 %

0 m

100 %

1Pokój

+20°C 1976/0 W

2Kuchnia

+20°C 429/0 W

dn A1/3

dn A1/2

dn A1/4

V-EXAKT-DTdn

V-EXAKT-DTdn

+ 3.00

+ 6.00

0 m

100 %

0 m

100 %

3W.C.

+20°C 110/0 W

4Sień

+16°C 218/0 W

dn A2/3

dn A2/2

dn A2/4

V-EXAKT-DTdn

V-EXAKT-DTdn

0 m

100 %

0 m

100 %

0 m

100 %

0 m

100 %

101Pokój

+20°C 1109/0 W

102Łazienka

+25°C 507/0 W

103W.C.

+20°C 0/0 W

104Pokój

+20°C 554/0 W

dn A1/103

dn A1/104

dn A2/103

dn A2/104

dn A2/102

dn A1/101

V-EXAKT-DTdn

V-EXAKT-DTdn

V-EXAKT-DTdn

V-EXAKT-DTdn

Ready blocks

0 m

100 %

0 m

100 %

103W.C.

+20°C 0/0 W

104Pokój

+20°C 554/0 W

dn A2/103

dn A2/104

dn A2/102

V-EXAKT-DTdn

V-EXAKT-DTdn

Automatically renumbered rooms Automatically

renumbered pipe-runs

Copy up

Page 29: SANKOM Sp. z o.o.  Introduction

C11-601.8 m

1500 W

C11-601.8 m

1500 W

C11-600.5 m

500 W

C11-600.5 m

500 W

C11-600.6 m

700 W

C11-600.6 m

700 W

C11-600.9 m

1000 W

C11-600.9 m

1000 W

3Pokój

+20°C 1000 W

PIWPiwnica+5°C 0 W

4Kuchnia

+20°C 700 W

5£azienka

+25°C 500 W

6Pokój

+20°C 1500 W

103Pokój

+20°C 1000 W

104Kuchnia

+20°C 700 W 105£azienka

+25°C 500 W

106Pokój

+20°C 1500 WKLKlatka

+16°C 0 W

dn

15

2/3

dn

18

2/1

dn

12

2/6

dn

18

2/4

dn

12

2/9

dn

18

2/7

dn

15

2/1

2

dn

15

2/1

0

dn

15

2/1

03

dn

18

2/1

01

dn

12

2/1

06

dn

18

2/1

04

dn

12

2/1

09

dn

18

2/1

07

dn

15

2/1

12

dn

15

2/1

10

dn 152/20

dn 20R/1

RTD-Kdn 15 n 3

RTD-Kdn 15 n 3

V2000-D-Vdn 10 n 3

EE

M-V

M-1

dn

15

V2000-D-Vdn 10 n 2.4

V2000-D-Vdn 10 n 7

V2000-D-Vdn 10 n 3

EE

M-V

M-1

dn

15

V2000-D-Vdn 10 n 2.25

V2000-D-Vdn 10 n 7

KOMBI-3+ -Ndn 15 n 3.6

KOMBI-3+ -Ndn 15 n 5

Rys 1

Przyk³ad 2

Projektowa³: mgr in¿. P. Wereszczyñski

Weryfikowa³:

Warszawa, ul. Nowowiejska 20

Kreœli³: Rettig C.O.Skala 1:50

Przyk³adowy projekt instalacji C.O.

Adres:

Radson C.O.

The hThe horizontal apartment systemorizontal apartment system

Block valves

GET-81.8 m

1500 W

GET-80.5 m

500 W

5Łazienka

+25°C 500 Wd

n 1

22

/9

dn

18

2/7

dn

15

2/1

2

dn

15

2/1

0

ZESAV6-Pdn 15 n 3

AV6-Pdn 10 n 7

Rys 1

Przykład 2

Projektował: mgr inż. P. Wereszczyński

Weryfikował:

Warszawa, ul. Nowowiejska 20

Kreślił: Audytor C.O.Skala 1:50

Przykładowy projekt instalacji C.O.

Adres:

Drawing tables

Page 30: SANKOM Sp. z o.o.  Introduction

The mThe manifold apartment systemanifold apartment system

n 2VKO11-60

0.5 m

500 W

n 2VKO11-60

0.5 m

500 W

GET-80.6 m

700 W

GET-80.6 m

700 W

GET-81 m

1000 W

GET-81 m

1000 W

5Pokój

+20°C 1000/0 W

4Łazienka

+25°C 500/0 W

3Kuchnia

+20°C 700/0 W

105Pokój

+20°C 1000/0 W

103Kuchnia

+20°C 700/0 W

KOTLKotłownia

+20°C 0/0 W

104Łazienka

+25°C 500/0 W

dn

16

AQ

100

01

/P00

5

dn

16

AQ

500

1/P

004

dn

16

AQ

700

1/P

003

dn

16

AQ

100

01

/P10

5

dn

16

AQ

700

1/P

103

dn 40 AQ 27900

1/2

dn 32 AQ 18600

1/102

dn 40 AQ 37200

R/1

dn

16

AQ

500

1/P

104

HY

DR

CO

NT

d

n 1

5 n

1.6

CO

MB

I-Q

1.5

dn

15

HY

DR

CO

NT

d

n 1

5 n

1

CO

MB

I-Q

1.5

dn

15

AV6-Pdn 15 n 4

AV6-Pdn 15 n 3.5

HY

DR

CO

NT

d

n 1

5 n

1.8

CO

MB

I-Q

1.5

dn

15

HY

DR

CO

NT

d

n 1

5 n

1

CO

MB

I-Q

1.5

dn

15

AV6-Pdn 15 n 4.5

AV6-Pdn 15 n 3.5

INTEGRA radiators

Page 31: SANKOM Sp. z o.o.  Introduction

3‰

3‰

GET-80.4 m

444 W

GET-80.7 m

610 W

GP-MARMUR dn=17 Q=346 WFc=5.7 Lc=28.0 B=0.2Fb=1.1 Lb=3.9 Bb=0.1

GP-MARMUR dn=17 Q=1123 WFc=15.5 Lc=78.3 B=0.2Fb=1.1 Lb=8.1 Bb=0.1

O3Pracownia

+20°C 610 W

1Pokój

+20°C 1728 W

dn 16 A1/2

dn 16 AR/6

dn 20 A1/3

dn

17

B1

/5

dn

17

B1

/4

dn 20 AR/4

dn 16 AR/7

dn 20 AR/2

dn 20 AR/1

dn 16 AR/8

ZT-PURMOdn 15

ZT-PURMOdn 15

AV6-Pdn 10 n 2

AV6-Pdn 10 n 3 V5433A-*

dn 15

V54

33

A-*

dn

15

HYDRCONTdn 15 n 4Z

P-P

UR

MO

dn

15

n

5

ZP

-PU

RM

Od

n 1

5

n 0

The uThe underfloor radiator systemnderfloor radiator system

Underfloor radiator

Mixing module

Page 32: SANKOM Sp. z o.o.  Introduction

DesigningDesigning the the underfloor radiatorsunderfloor radiators • Flexible definition Flexible definition of the of the underfloor radiator construction.underfloor radiator construction.

• Creation of the underfloor radiatorsCreation of the underfloor radiators catalogue.catalogue.

Layers above the pipes

Pipe-coil construction

Layers below the pipes

Page 33: SANKOM Sp. z o.o.  Introduction

Designing the Designing the underfloor radiatorsunderfloor radiators• Preliminary calculations.Preliminary calculations.

Unitary thermal efficiency

Information about pipes

Calculated pipe length and floor area

Floor temperature

Calculation temperatures

Hydraulic calculations’

results

Page 34: SANKOM Sp. z o.o.  Introduction

Designing the Designing the underfloor radiatorsunderfloor radiatorsPPrinting rinting the pthe preliminary calculations reliminary calculations results.results.

Work parameters

Radiator calculation results

Page 35: SANKOM Sp. z o.o.  Introduction

Radson C.O.

Drawing on the plan viewsDrawing on the plan views

KOMPAKT-**-60

GP-MARMUR dn=GP-MARMUR dn=GP-MARMUR dn=GP-MARMUR dn=GP-MARMUR dn=GP-MARMUR dn=GP-MARMUR dn=Fc=5.7 Lc= B=0.2Fc=5.7 Lc= B=0.2Fc=5.7 Lc= B=0.2Fc=5.7 Lc= B=0.2Fc=5.7 Lc= B=0.2Fc=5.7 Lc= B=0.2Fc=5.7 Lc= B=0.2Fb=1.3 Lb= Bb=Fb=1.3 Lb= Bb=Fb=1.3 Lb= Bb=Fb=1.3 Lb= Bb=Fb=1.3 Lb= Bb=Fb=1.3 Lb= Bb=Fb=1.3 Lb= Bb=

5

Pokój+20°C 723 W

dn A2/5

Underfloor radiators

Radiators

Pipes

Room labelsGraphic

tabViews tab

Importing the plan view form file (WMF, DZF,

DWG) or clipboardInstalation item

label

Border zone

Page 36: SANKOM Sp. z o.o.  Introduction

Radson C.O.

CCalculation resultsalculation resultsCalculation results may be presented both inCalculation results may be presented both in a a table table and and graphic graphicallyally..

Results in the graphical form

Results in the tabular form

Dynamic link between the tables and the system diagram

Valve preset value

Radiator size

Drawing layers formating

Setting layers visibility

Layer editing

Line styleFont style selection

Page 37: SANKOM Sp. z o.o.  Introduction

Radson C.O.

The calculation results The calculation results iin the plan viewn the plan view

Underfloor radiators Radiators (length scale

is saved)

Described pipes

Page 38: SANKOM Sp. z o.o.  Introduction

Presentation of calculation resultsPresentation of calculation results• TThe contents of all tables can be formatted (choice of rows and columns to he contents of all tables can be formatted (choice of rows and columns to

be shown, choice of be shown, choice of the the font size) and sorted according to font size) and sorted according to a a freely chosen freely chosen keykey..

• All drawings cAll drawings canan be transferred into another application using WMF, DXF be transferred into another application using WMF, DXF and DWG formatand DWG formatss..

• In case of In case of using using DXF and DWG filesDXF and DWG files,, the layers and blocks structure a the layers and blocks structure arere saved.saved.

• TThe contents of all tables can behe contents of all tables can be transferred into another application via transferred into another application via clipboard.clipboard.

Page 39: SANKOM Sp. z o.o.  Introduction

Printing Printing the calculation rthe calculation reessuultsltsCalculation results can be plotted to Calculation results can be plotted to aa plotter or plotter or a a printer printer . .

Plot preview Plot formatting

Plotting pagination

Printer or plotter selection

Plotting scale

Plotting Margins

Page 40: SANKOM Sp. z o.o.  Introduction

Examples of single-pipe radiator connectionsExamples of single-pipe radiator connections• Single-pipe systems are common in the countries of the former Soviet Single-pipe systems are common in the countries of the former Soviet

Union.Union.