s. e. tzamarias hellenic open university

23
1 S. E. Tzamarias S. E. Tzamarias Hellenic Open Hellenic Open University University N N eutrino eutrino E E xtended xtended S S ubmarine ubmarine T T elescope with elescope with O O ceanographic ceanographic R R esearch esearch Readout Electronics Readout Electronics DAQ & DAQ & Calibration Calibration

Upload: ryan-kidd

Post on 01-Jan-2016

24 views

Category:

Documents


2 download

DESCRIPTION

S. E. Tzamarias Hellenic Open University. N eutrino E xtended S ubmarine T elescope with O ceanographic R esearch Readout Electronics DAQ & Calibration. NESTOR TOWER. Hamamatsu PMT R2018-03 (15”) Benthos spheres μ- metal cage power supply. Single p.e. conditions. - PowerPoint PPT Presentation

TRANSCRIPT

Page 1: S. E. Tzamarias Hellenic Open University

1

S. E. TzamariasS. E. TzamariasHellenic Open Hellenic Open

UniversityUniversity

NNeutrino eutrino EExtended xtended SSubmarine ubmarine TTelescope with elescope with OOceanographic ceanographic

RResearchesearch

Readout Electronics Readout Electronics DAQ & Calibration DAQ & Calibration

Page 2: S. E. Tzamarias Hellenic Open University

2

NESTOR TOWERNESTOR TOWER

Page 3: S. E. Tzamarias Hellenic Open University

3

• Hamamatsu PMT R2018-03 (15”)

• Benthos spheres

• μ-metal cage

• power supply

Single p.e. conditions

The Detector

Page 4: S. E. Tzamarias Hellenic Open University

4

ReadOut Electronics & DAQ Chain

Page 5: S. E. Tzamarias Hellenic Open University

5

Signal transmission & ControlShore Laboratory Power supply

PMT signal transmission

low voltage supply (24V) control and monitoring signal transmission

House Keeping Board PMT control Calibration Beakon control PMT HV monitor Power Supply monitors Environmental monitors

Floor Board PMT pulse sensing Majority logic event triggering Single & coincidence rate scaling Waveform capture & digitization Data formatting & transmission FPGA & PLD reprogramming

Ti-Sphere ElectronicsTi-Sphere Electronics

Page 6: S. E. Tzamarias Hellenic Open University

6

Input: 12 PMT signals

Delay lines

Configuration parameters PLD

Trigger Logic & Communication FPGAs

5 ATWDs

Floor BoardFloor Board PMT pulse sensing Majority logic event triggering Single & coincidence rate scaling Waveform capture & digitization Data formatting & transmission FPGA & PLD reprogramming

PMT Signal Capture & Digitization

Page 7: S. E. Tzamarias Hellenic Open University

7

The LED Calibration System

Frequency

Duration

Light amplitude

20m

20m

• Gain monitoring

• Timing

• Free running Calibration Trigger

• Adjustable Trigger frequency

• Adjustable LED’s light output

Page 8: S. E. Tzamarias Hellenic Open University

8

Extensive Lab tests

On single p.e. conditions

Detector Preparation

Calibration at the Lab

L.E.D.Reference

Relative timing

                                

                   

Pulse Height (mV)

LED Calibration Run

Time Difference in PMTs Response

Time (ns)

Page 9: S. E. Tzamarias Hellenic Open University

9

Detector Preparation

Attenuation Correction

                                

                  

Reference waveform

Coaxial cable

Electronic delay lines and amplifier

Fourier Transform-ComparisonFrequency (MHz)

Frequency (MHz)

Ph

ase

(rad

)A

mp

litu

de

Page 10: S. E. Tzamarias Hellenic Open University

10

Num

ber

of P

.E.s

/ s

r /L

ight

Pul

se Laboratory measurements

PMT Geometrical Factor: 3.46 ·10-4

Transmission Factor: 0.72

Parameterized Angular Profile of the LED emission in air

Estimated Angular Profile of the LED emission in water

LED Angular Profile

Angle (Degrees)

Page 11: S. E. Tzamarias Hellenic Open University

11

to the floor board

Data Files

Delete Data Storage

Event samples

Monitor

Offline

fast analysis

DAQ Architecture

Page 12: S. E. Tzamarias Hellenic Open University

12

Online Software

Shore Board Downloads the FPGAs & PLD of the Floor Board Broadcasts the 40Mhz clock Receives Data from the Floor Board Transmits Data to the Run Control System

Page 13: S. E. Tzamarias Hellenic Open University

13

Event samples

Monitor

Real Time Monitor Environmental

• Thermometers

• Hygrometers

•Compass

•Inclinometer/Accelerometer

• Pressure meter

Electrical

• PMT High Voltage etc

Digitization & DAQ Performance

• Digitized waveforms

• PMT rates

• Trigger rates

• DAQ status

Page 14: S. E. Tzamarias Hellenic Open University

14

Real Time MonitorsReal Time Monitors

Sample

448 ns

Page 15: S. E. Tzamarias Hellenic Open University

During deployment

Page 16: S. E. Tzamarias Hellenic Open University

16

Waveform ReconstructionWaveform Reconstruction

Sample Offset (ADC counts)Sample

Off

set

(AD

C c

oun

ts)

Before the F.F.T. and the attenuation corrections

After the F.F.T. and the attenuation corrections

Rise Time

16 ns

9 ns Double pulse separation

Time (ns)

Vol

tage

(m

V)

Page 17: S. E. Tzamarias Hellenic Open University

17

Waveform Reconstruction

DST Production

Hit DefinitionData Quality Histograms

Sample

AD

C C

oun

ts

40 MHz Clock Waveform Capture

Event by Event Sampling Interval Variation (Constant Temperature)

Time (ns)

RMS=0.006 ns

Software to Hardware Trigger Time Difference (arbitrary time offset)

σ=0.7ns

Page 18: S. E. Tzamarias Hellenic Open University

18

single p.e.

LED Run

single p.e. pulse height distribution

two p.e.s pulse height distribution

dark current pulse height distribution

sum of the above

Data from a depth of 4000 m

Calibration using the natural radiactivity (K40)

Calibration

Page 19: S. E. Tzamarias Hellenic Open University

19

Calibration Data Analysis

Calibration Database Quality Histograms

LED Calibration Data

Gain Monitors

Data from a depth of 4000 mCalibration Run

Time Difference (ns)

Nu

mb

er o

f E

ven

tsN

um

ber

of

Eve

nts

Time Difference (ns)

<Δt>: 0.6 ± 0.1 ns

σ : 3.3 ± 0.1 ns

<Δt>: 0.2 ± 0.1 ns

σ : 3.3 ± 0.1 ns

Page 20: S. E. Tzamarias Hellenic Open University

20

Data from a depth of 4000 mCalibration Run

Page 21: S. E. Tzamarias Hellenic Open University

21

Data from a depth of 4000 mSingle PMT Rates

Trigger: ≥4fold Coincidence

Page 22: S. E. Tzamarias Hellenic Open University

22

Data from a depth of 4000 mTrigger Studies

Preliminary

Coincidence Level

Coincidence Level

Tri

gg

er

Ra

te (

Hz)

To

tal

Ch

arg

e i

ns

ide

th

e T

rig

ge

r W

ind

ow

Experimental Points

M.C. Estimation (Atmospheric muons + K40 )

Data Collected with

4fold Majority Trigger

Thresholds at 30mV

(1/4 P.E.)

Page 23: S. E. Tzamarias Hellenic Open University

23

Data from a depth of 4000 mTrigger Studies

Preliminary

Coincidence Level

Coincidence Level

Tri

gg

er

Ra

te (

Hz)

To

tal

Ch

arg

e i

ns

ide

th

e T

rig

ge

r W

ind

ow

Experimental Points

M.C. Estimation (Atmospheric muons + K40 )

Data Collected with

4fold Majority Trigger

Thresholds at 120mV

(1 P.E.)