8/10/2019 Roland Error
http://slidepdf.com/reader/full/roland-error 1/2
Error Message Model Cause Action
1INTERNAL ERROR: UNEXPECTED EXCEPTION OCCURED
THE FACTOR IS [EXC_USER_BREAK]CJ-70 The CJ-70 receives the wrong RTL data. Check the file itself.
2INTERNAL ERROR - UNEXPECTED EXCEPT ON OCCUR.
THE FACT IS: [ EXC- ADDR- ERR-RD ]FJ-50
This message appears when there is a problem processing the
program (Firmware) of the FJ internally.Turning off and on the power again.
3INTERNAL ERROR: HEAD DRIVER :
ILLEGAL FLUSHING START TIME:00FJ-50 There is a bug in the f irmware ver .1 .7 and below. Upgrade the f irmware to the latest one.
4INTERNAL ERROR / Print Manager / illegal message /
PRINT ST FREE /FUSH ST WAITEND / MIO PRINT DI SABLE /
000B 0004
FJ-50 There is a bug in the f irmware ver .1 .7 and below. Upgrade the f irmware to the latest one.
5Internal exception occur the factor is
EXE USER BREAKFJ-50
This error means "don't access.
It accessed to the memory field".Check the file itself.
6INTERNALERROR: TAT . . 05: HEAD DRIVER
. . START FLASH IN HEAD"FJ-50 Upgrade the firmware to the latest one.
7
Internal Error Unexpected Exception occurred
- EXC. Adress Error
- EXC. User Break
FJ-50 There is some unusual data received by the FJ. Check the file itself.
8 Internal Error FPGA : write error 2 FJ-52 Signal transmission inside the main board is not properly doneRemove the conductive dust on the main board, or replace themain board.
9INTERNAL ERROR: MCONNECT_DISPATCH:
MISTAKE TO CONNECT PRINT CARRIAGE".CJ-500
Something unusual is happening at the Locking
Mechanism of the Head Carriage
1. The Lock Assembly is not loose.
2. The CASE, LOCK (ref#14 in service note p.4) is aligned
correctly to the projection of the Guide Rail.
10 INTERNAL ERROR, GLOBAL MEMORY" CJ-500It seems like the memory has become full
to continue its job.Turning off and on the power again.
11 internal error" also "cannot allocate frame CJ-500 There is a problem in the sent data.Make sure that the data is sent correctly or the setting
is done correctly.
12 internal error, exc user error' CJ-500 The CPU is not processing correctly.
1. Check the file.
2. Change the PC and interface cable.
3. Main board is broken.
13Internal Error No Local Memory CJ-500 The machine drops the data during the transmission. Upgrade the firmware to the latest one.
14 0000012 FJ-500 It accesses the wrong address. Turning off and on the power again.
15 0000007 FJ-500 The unexpected command is sent. Turning off and on the power again.
16 Internal error 1240268 FJ-600Encoder of Scan Motor/Linear Encoder might not work
correctly.LINEAR ENCODER SETUP
INTERNAL ERROR
8/10/2019 Roland Error
http://slidepdf.com/reader/full/roland-error 2/2
17 Internal Error 1300145 FJ-600
This means that the size of the stocked memory (data)in the Main
Board is different from the size of the released memory to the
Printer.Turning off and on the power again.
18 Internal Error 0050057 FJ-500This error means that this port doesn't exist.
There might be an error when accessing to the mainboard.Turning off and on the power again.