A SEMINAR ON RADIOIMMUNOASSAY
Guided by: Preseanted by-Mr. J.D.Patel Patel AkshayDept. of Q.A. M.pharm (sem-I)
NOOTAN PHARMACY COLLEGE,VISNAGAR.
![Page 2: RIA ppt akshay patel](https://reader033.vdocuments.us/reader033/viewer/2022061111/5455cce8af7959aa368b7baa/html5/thumbnails/2.jpg)
2
Introduction:An immunoassay is a test that uses antibody and antigen complexes as a means of generating a measurable result. An antibody: antigen complex is also known as an immune-complex.
Immunoassays are different from other types of laboratory tests, such as colorimetric tests, because they use antibody: antigen complexes to generate a signal that can be measured.
In contrast, most routine clinical chemistry tests utilize chemical reactions between the reagent (a solution of chemicals or other agents) and patient sample to generate a test result.
![Page 3: RIA ppt akshay patel](https://reader033.vdocuments.us/reader033/viewer/2022061111/5455cce8af7959aa368b7baa/html5/thumbnails/3.jpg)
Principle: Uses an immune reaction [Antigen – Antibody reaction] to estimate a ligand
Ag + Ag* + Ab AgAb + Ag*Ab + Ag + Ag*
◦ Unbound Ag* and Ag washed out ◦ Radioactivity of bound residue measured◦ Ligand conc is inversely related to radioactivity
[Ag : ligand to be measured ; Ag* radiolabelled ligand]
![Page 4: RIA ppt akshay patel](https://reader033.vdocuments.us/reader033/viewer/2022061111/5455cce8af7959aa368b7baa/html5/thumbnails/4.jpg)
4
What is a label?
•All immunoassays require the use of labeled material in order to measure the amount of antigen or antibody present.
•A label is a molecule that will react as part of the assay, so a change in signal can be measured in the blood:reagent solution.
•Examples of a label include-•a radioactive compound, •an enzyme that causes a change of color in a solution,•a substance that produces light.
![Page 5: RIA ppt akshay patel](https://reader033.vdocuments.us/reader033/viewer/2022061111/5455cce8af7959aa368b7baa/html5/thumbnails/5.jpg)
5
Labeled antibodies allow detection of antigen/antibody complexes in immunoassays
Labeled antigen also allows detection of antigen/antibody complexes in immunoassays
![Page 6: RIA ppt akshay patel](https://reader033.vdocuments.us/reader033/viewer/2022061111/5455cce8af7959aa368b7baa/html5/thumbnails/6.jpg)
6
Classification of immunoassays:
1.Competitive & Non-competitive immunoassays.
2.Homogeneous & Heterogeneous immunoassays.
3.Limited reagent assays & Excess reagent assays.
![Page 7: RIA ppt akshay patel](https://reader033.vdocuments.us/reader033/viewer/2022061111/5455cce8af7959aa368b7baa/html5/thumbnails/7.jpg)
7
Competitive format
Amount of antigen is indirectly related to the amount of label (signal) in competitive
formats
![Page 8: RIA ppt akshay patel](https://reader033.vdocuments.us/reader033/viewer/2022061111/5455cce8af7959aa368b7baa/html5/thumbnails/8.jpg)
8
One step competitive immunoassay
Two step competitive immunoassay
![Page 9: RIA ppt akshay patel](https://reader033.vdocuments.us/reader033/viewer/2022061111/5455cce8af7959aa368b7baa/html5/thumbnails/9.jpg)
9
Noncompetitive (Sandwich) Method
Noncompetitive sandwich method of immunoassay
![Page 10: RIA ppt akshay patel](https://reader033.vdocuments.us/reader033/viewer/2022061111/5455cce8af7959aa368b7baa/html5/thumbnails/10.jpg)
10
Amount of antigen is directly related to the amount of label (signal) in competitive formats
![Page 11: RIA ppt akshay patel](https://reader033.vdocuments.us/reader033/viewer/2022061111/5455cce8af7959aa368b7baa/html5/thumbnails/11.jpg)
11
Homogeneous and Heterogeneous Immunoassay Methods
Homogeneous and heterogeneous immunoassays
![Page 12: RIA ppt akshay patel](https://reader033.vdocuments.us/reader033/viewer/2022061111/5455cce8af7959aa368b7baa/html5/thumbnails/12.jpg)
12
Limited reagent assay:
Many conventional RIAs follow limited reagent assay protocols.The following scheme depicts the AgAb reaction:
Ag AgAb+ Ab
Ag* Ag*Ab
With limited amount of Ab, the unlabeled antigen (analyte) competes with the labeled antigen Ag* for limited binding sites.
Bound fraction [AgAb] is separated from free [Ab], and the signal [Ag*Ab] complex i.e. the Ab fraction not occupied by the analyte is measured.
The amount of analyte is inversely proportional to the bound [Ag*Ab] complex in a hyperbolic function.
![Page 13: RIA ppt akshay patel](https://reader033.vdocuments.us/reader033/viewer/2022061111/5455cce8af7959aa368b7baa/html5/thumbnails/13.jpg)
13
Excess-Reagent assay
This protocol is utilized by- 1. Immunoradiometric Assays (IRMA). 2. Two-site or sandwich Assays.
Here the excess Ab is labeled.(In case of sandwich assay an excess amount of first Ab used to capture analyte from sample matrix, and a labeled second Ab provides the signal for quantitation.)
IRMA: Ag + Ab* AgAb*
Sandwich assay: Ag + Ab1 Ag-Ab1 + Ab2*
Ab1-Ag-Ab2*
Bound fraction is separated from free; the signal [AgAb*] or [Ag-Ab1-Ab2*] complex is measured.The amount of analyte is proportional to the bound complex in a hyperbolic function.
![Page 14: RIA ppt akshay patel](https://reader033.vdocuments.us/reader033/viewer/2022061111/5455cce8af7959aa368b7baa/html5/thumbnails/14.jpg)
14
General procedure for RIA:
A known quantity of an antigen is made radioactive, frequently by labeling it with gamma-radioactive isotopes of iodine attached to tyrosine.
This radiolabeled antigen is then mixed with a known amount of antibody for that antigen, and as a result, the two chemically bind to one another.
Then, a sample of serum from a patient containing an unknown quantity of that same antigen is added. This causes the unlabeled (or "cold") antigen from the serum to compete with the radiolabeled antigen for antibody binding sites.
![Page 15: RIA ppt akshay patel](https://reader033.vdocuments.us/reader033/viewer/2022061111/5455cce8af7959aa368b7baa/html5/thumbnails/15.jpg)
15
the concentration of "cold" antigen is increased, more of it binds to the antibody, displacAs ing the radiolabeled variant, and reducing the ratio of antibody-bound radio labeled antigen to free radio labeled antigen.
The radioactivity falls because unlabelled antigen dilute it .
The count obtained from the radioactivity are used to determine the hapten concentration in the sample, the interpretetion being done on the stnadard curve.
![Page 16: RIA ppt akshay patel](https://reader033.vdocuments.us/reader033/viewer/2022061111/5455cce8af7959aa368b7baa/html5/thumbnails/16.jpg)
1. Preparation & characterisation of the Antigen [Ligand to be analysed]
2. Radiolabelling of the Antigen3. Preparation of the Specific
Antibody4. Development of Assay System
![Page 17: RIA ppt akshay patel](https://reader033.vdocuments.us/reader033/viewer/2022061111/5455cce8af7959aa368b7baa/html5/thumbnails/17.jpg)
Antigens prepared by.. ◦ Synthesis of the molecule ◦ Isolation from natural sources
Radiolabelling [Tagging procedure]◦ 3 H 14 C 125 I are used as radioactive tags◦ Antigens are tagged to 3 H 14 C 125
◦ Tagging should NOT affect Antigenic specificity & Antigenic activity !
![Page 18: RIA ppt akshay patel](https://reader033.vdocuments.us/reader033/viewer/2022061111/5455cce8af7959aa368b7baa/html5/thumbnails/18.jpg)
Antigen injected intradermally into rabbits or guinea pigs antibody production
Antibodies recovered from the serum
Some ligands are not Antigenic ◦ Hormones, Steroids, Drugs HAPTENS◦ Eg: Gastrin, Morphine, ◦ Haptens conjugated to albumin antigenic
![Page 19: RIA ppt akshay patel](https://reader033.vdocuments.us/reader033/viewer/2022061111/5455cce8af7959aa368b7baa/html5/thumbnails/19.jpg)
Add known amounts of the test sample + labelled antigen into the microtitre wells
Incubate allow the reaction to reach completion
Decant & wash contents of the well removes all unbound antigens
Radioactivity remaining in the Microtitre wells measured by a Counter [GM counter , Scintillation counter etc]
Intensity of radioactivity is inversely correlated with the conc of antigens in the test sample
Sensitive to very low conc of antigens
![Page 20: RIA ppt akshay patel](https://reader033.vdocuments.us/reader033/viewer/2022061111/5455cce8af7959aa368b7baa/html5/thumbnails/20.jpg)
20
Plot of Bound versus Total Drug Concentration
Logit versus Log Total C Plot
![Page 21: RIA ppt akshay patel](https://reader033.vdocuments.us/reader033/viewer/2022061111/5455cce8af7959aa368b7baa/html5/thumbnails/21.jpg)
1)Centrifuge :
swing bucket rotor : 1200-2500 rpm.Fixed angle head rotor : 3500-4000 rpm.
2) Radioactive counterA) gamma counter : which is used for agmma
energy emiting isotopes. E.g. 125 I .B) scintilation counter : It is used for beta energy
emitting isotopes . Eg. Tritium 3H and 14 C isotopes.
![Page 22: RIA ppt akshay patel](https://reader033.vdocuments.us/reader033/viewer/2022061111/5455cce8af7959aa368b7baa/html5/thumbnails/22.jpg)
Advantages◦ Highly specific: Immune reactions are specific◦ High sensitivity : Immune reactions are
sensitive
Disadvantages ◦ Radiation hazards: Uses radiolabelled reagents◦ Requires specially trained persons◦ Labs require special license to handle
radioactive material◦ Requires special arrangements for
Requisition, storage of radioactive material radioactive waste disposal.
![Page 23: RIA ppt akshay patel](https://reader033.vdocuments.us/reader033/viewer/2022061111/5455cce8af7959aa368b7baa/html5/thumbnails/23.jpg)
Insulin Gastrin Glucagon Growth hormones Morphine Clonazepam Barbiturates Neobentine Flurazepam
![Page 24: RIA ppt akshay patel](https://reader033.vdocuments.us/reader033/viewer/2022061111/5455cce8af7959aa368b7baa/html5/thumbnails/24.jpg)
THANK YOU…