revision:sheet:date:architect:customer:job...

12

Upload: dophuc

Post on 12-Aug-2019

214 views

Category:

Documents


0 download

TRANSCRIPT

AutoCAD SHX Text
W
AutoCAD SHX Text
REVISION:
AutoCAD SHX Text
SHEET:
AutoCAD SHX Text
OF
AutoCAD SHX Text
DATE:
AutoCAD SHX Text
ARCHITECT:
AutoCAD SHX Text
CUSTOMER:
AutoCAD SHX Text
JOB NUMBER:
AutoCAD SHX Text
AGENT:
AutoCAD SHX Text
DWG BY:
AutoCAD SHX Text
CHK BY:
AutoCAD SHX Text
BANCROFT ELEMENTARY
AutoCAD SHX Text
2200 Parish Dr, Walnut Creek, CA 94598
AutoCAD SHX Text
GCK
AutoCAD SHX Text
JLP
AutoCAD SHX Text
12-28-18
AutoCAD SHX Text
1
AutoCAD SHX Text
3
AutoCAD SHX Text
NOTES: SCOPE OF WORK INCLUDED BUT NOT LIMITED TO: RESTORATION. INDICATED WITH (W). 1. REMOVE AND REPLACE ALL BASE FLASHINGS ALONG PARAPET WALLS WITH NEW 2 PLY MODIFIED SYSTEM IN GREEN-LOCK FLASHING ADHESIVE. 2. REMOVE AND REPLACE MEMBRANE IN PERIMETER DRAINAGE AREA 5' FROM EDGE. INSTALL NEW 2 PLY MODIFIED SYSTEM IN GREEN-LOCK MEMBRANE ADHESIVE. NAIL RED ROSIN PAPER. REPLACE ANY INSULATION TO MATCH EXISTING. 3. REMOVE AND REPLACE ALL GUTTERS. STRIP IN WITH NEW TWO PLY MODIFIED SYSTEM IN GREEN-LOCK FLASHING ADHESIVE. 4. POWER WASH ROOF SYSTEM WITH SIMPLEGREEN/TSP AND WATER SOLUTION. 5. PRIME ROOF WITH GARLA-BLOCK AT 0.5 GALLONS/SQUARE. 6. APPLY WHITE-STAR AT 2 GALLONS PER SQUARE. 7. IMMEDIATELY EMBED 200LBS PER SQUARE OF TITLE 24 APPROVED 3/8" GRAVEL. 8. APPLY PYRAMIC IN 2 COATS TO ALL BASE FLASHINGS. (1.5 GALLONS A SQUARE PER COAT) 9. ALL CONDUIT, VENTS, AND HOODS TO BE PAINTED WITH DISTRICT COLOR SELECTION. NOTE: REFER TO MANUFACTURERS INSTALLATION INSTRUCTIONS AND SPECS FOR COMPLETE DETAILS.
AutoCAD SHX Text
ROOF PLAN
AutoCAD SHX Text
N
AutoCAD SHX Text
SCALE: 1" = 10'
AutoCAD SHX Text
LEGEND: = SOLID HATCHED AREAS ARE N.I.C.

SCALE: NTS

H

2

ROOF DRAIN

SCALE: NTS

E

2

EQUIPMENT SUPPORT

SCALE: NTS

G

2

EXHAUST FAN DETAIL

SCALE: NTS

F

2

SKYLIGHT

SCALE: NTS

D

2

EQUIPMENT SUPPORT

SCALE: NTS

C

2

RAISED METAL EDGE

SCALE: NTS

B

2

TYPICAL - GRAVEL FINISH

SCALE: NTS

A

2

TYPICAL - COATED FINISH

AutoCAD SHX Text
WOOD DECK
AutoCAD SHX Text
INSULATION
AutoCAD SHX Text
STAGGER ALL JOINTS
AutoCAD SHX Text
FASTEN ACCORDING TO SPECIFICATION
AutoCAD SHX Text
HPR MODIFIED MEMBRANE
AutoCAD SHX Text
WITH A REFLECTIVE SURFACE
AutoCAD SHX Text
ADHESIVE
AutoCAD SHX Text
BASE PLY
AutoCAD SHX Text
SEE SPECIFICATION FOR SURFACING
AutoCAD SHX Text
ALL PLIES SET IN MODIFIED COLD ADHESIVE
AutoCAD SHX Text
RECOVERY BOARD
AutoCAD SHX Text
MODIFIED COLD
AutoCAD SHX Text
AGGREGATE SURFACE
AutoCAD SHX Text
HPR MODIFIED MEMBRANE
AutoCAD SHX Text
ALL PLIES SET IN MODIFIED COLD ADHESIVE
AutoCAD SHX Text
SEE SPECIFICATION FOR SURFACING
AutoCAD SHX Text
BASE PLY
AutoCAD SHX Text
ADHESIVE
AutoCAD SHX Text
WOOD DECK
AutoCAD SHX Text
FASTEN ACCORDING TO SPECIFICATION
AutoCAD SHX Text
STAGGER ALL JOINTS
AutoCAD SHX Text
INSULATION
AutoCAD SHX Text
RECOVERY BOARD
AutoCAD SHX Text
MODIFIED COLD
AutoCAD SHX Text
[102mm]
AutoCAD SHX Text
4" MIN.
AutoCAD SHX Text
[152mm] ON FIELD
AutoCAD SHX Text
BASE FLASHING PLY 6" MIN.
AutoCAD SHX Text
HPR MODIFIED MEMBRANE FLASHING PLY
AutoCAD SHX Text
9" MIN [228mm] ON FIELD
AutoCAD SHX Text
INSULATION STAGGER ALL JOINTS, FASTEN PER SPECIFICATION
AutoCAD SHX Text
HPR MODIFIED MEMBRANE
AutoCAD SHX Text
BASE PLY
AutoCAD SHX Text
CONTINUOUS CLEAT FASTENED 6" O.C. [152mm]
AutoCAD SHX Text
EXTEND ONE PLY OVER BLOCKING FASTEN 8" O.C. [203mm]
AutoCAD SHX Text
METAL EDGE SET IN ROOF CEMENT NAILED 3" O.C. [76mm] STAGGERED PRIME METAL FLANGE PRIOR TO STRIPPING
AutoCAD SHX Text
POLYURETHANE SEALANT
AutoCAD SHX Text
WOOD DECK
AutoCAD SHX Text
ALL PLIES SET IN MODIFIED COLD ADHESIVE SEE SPECIFICATIONS FOR SURFACING
AutoCAD SHX Text
4" MAX
AutoCAD SHX Text
24" MAX.
AutoCAD SHX Text
[610mm]
AutoCAD SHX Text
CONTINUOUS CLEAT
AutoCAD SHX Text
WITH NEOPRENE WASHERS THROUGH
AutoCAD SHX Text
SLOPE PER SPECIFICATION
AutoCAD SHX Text
FASTENERS APPROX. 24" O.C. [610mm]
AutoCAD SHX Text
METAL COPING
AutoCAD SHX Text
FASTENED 6" O.C. [152mm]
AutoCAD SHX Text
[152mm] ON FIELD
AutoCAD SHX Text
CANT STRIP
AutoCAD SHX Text
BASE FLASHING PLY 6" MIN.
AutoCAD SHX Text
HPR MODIFIED MEMBRANE FLASHING PLY
AutoCAD SHX Text
9" MIN [228mm] ON FIELD
AutoCAD SHX Text
ALL PLIES SET IN MODIFIED COLD ADHESIVE SEE SPECIFICATIONS FOR SURFACING
AutoCAD SHX Text
INSULATION STAGGER ALL JOINTS, FASTEN PER SPECIFICATION
AutoCAD SHX Text
HPR MODIFIED MEMBRANE
AutoCAD SHX Text
BASE PLY
AutoCAD SHX Text
WOOD DECK
AutoCAD SHX Text
PRE-PUNCHED ELONGATED HOLES
AutoCAD SHX Text
8" MIN.
AutoCAD SHX Text
[203mm]
AutoCAD SHX Text
INSULATION STAGGER ALL JOINTS, FASTEN PER SPECIFICATION
AutoCAD SHX Text
BASE PLY
AutoCAD SHX Text
ALL PLIES SET IN MODIFIED COLD ADHESIVE SEE SPECIFICATIONS FOR SURFACING
AutoCAD SHX Text
METAL CAP SECURED APPROX. 24" O.C. [610mm] W/ FASTENERS & NEOPRENE WASHERS
AutoCAD SHX Text
HPR MODIFIED MEMBRANE FLASHING PLY 9" MIN. [228mm] ON FIELD
AutoCAD SHX Text
BASE FLASHING PLY 6" MIN. [152mm] ON FIELD
AutoCAD SHX Text
NEOPRENE PAD
AutoCAD SHX Text
HPR MODIFIED MEMBRANE
AutoCAD SHX Text
HPR FLASHING FASTENED 8" O.C. [203mm]
AutoCAD SHX Text
BOLTS WITH NEOPRENE WASHERS
AutoCAD SHX Text
WOOD DECK
AutoCAD SHX Text
CANT FASTENED TO NAILER
AutoCAD SHX Text
2" X 10" MINIMUM [51mm X 254mm]
AutoCAD SHX Text
SKYLIGHT
AutoCAD SHX Text
METAL COUNTERFLASHING FASTENED 8" O.C. [203mm] WITH NEOPRENE WASHERS
AutoCAD SHX Text
ALL PLIES SET IN MODIFIED COLD ADHESIVE SEE SPECIFICATIONS FOR SURFACING
AutoCAD SHX Text
HPR MODIFIED MEMBRANE FLASHING PLY 9" MIN. [228mm] ON FIELD
AutoCAD SHX Text
BASE FLASHING PLY 6" MIN. [152mm] ON FIELD
AutoCAD SHX Text
EXTRUDED ALUMINUM FRAM WITH WEEP HOLES
AutoCAD SHX Text
INSULATION STAGGER ALL JOINTS, FASTEN PER SPECIFICATION
AutoCAD SHX Text
HPR MODIFIED MEMBRANE
AutoCAD SHX Text
BASE PLY
AutoCAD SHX Text
WOOD DECK
AutoCAD SHX Text
[203mm]
AutoCAD SHX Text
8" MIN.
AutoCAD SHX Text
ALL PLIES SET IN MODIFIED COLD ADHESIVE SEE SPECIFICATIONS FOR SURFACING
AutoCAD SHX Text
HPR MODIFIED MEMBRANE FLASHING PLY 9" MIN. [228mm] ON FIELD
AutoCAD SHX Text
BASE FLASHING PLY 6" MIN. [152mm] ON FIELD
AutoCAD SHX Text
HPR FLASHING FASTENED 8" O.C. [203mm]
AutoCAD SHX Text
WOOD DECK
AutoCAD SHX Text
INSULATION, STAGGER ALL JOINTS, FASTEN PER SPECIFICATIONS
AutoCAD SHX Text
HPR MODIFIED MEMBRANE
AutoCAD SHX Text
BASE PLY
AutoCAD SHX Text
METAL EXHAUST FAN COVER
AutoCAD SHX Text
CANT STRIP
AutoCAD SHX Text
WOOD DECK
AutoCAD SHX Text
DECK CLAMP
AutoCAD SHX Text
CLAMPING RING
AutoCAD SHX Text
STRAINER
AutoCAD SHX Text
ALL PLIES SET IN MODIFIED COLD ADHESIVE SEE SPECIFICATIONS FOR SURFACING
AutoCAD SHX Text
BASE FLASHING PLY 40" [1016mm]
AutoCAD SHX Text
HPR MODIFIED MEMBRANE
AutoCAD SHX Text
BASE PLY
AutoCAD SHX Text
HPR MODIFIED MEMBRANE MIN. 48" [1219mm]
AutoCAD SHX Text
TAPER INSULATION 24" MIN. [610mm] FROM CENTER OF DRAIN, STAGGER ALL JOINTS, FASTEN PER SPECIFICATION
AutoCAD SHX Text
LEAD FLASHING 30" SQ. MIN. [762] SET IN MASTIC, WRAPPED DOWN 2" MIN. [51mm], PRIME TOP SURFACE BEFORE FLASHING
AutoCAD SHX Text
REVISION:
AutoCAD SHX Text
SHEET:
AutoCAD SHX Text
OF
AutoCAD SHX Text
DATE:
AutoCAD SHX Text
ARCHITECT:
AutoCAD SHX Text
CUSTOMER:
AutoCAD SHX Text
JOB NUMBER:
AutoCAD SHX Text
AGENT:
AutoCAD SHX Text
DWG BY:
AutoCAD SHX Text
CHK BY:
AutoCAD SHX Text
BANCROFT ELEMENTARY
AutoCAD SHX Text
2200 Parish Dr, Walnut Creek, CA 94598
AutoCAD SHX Text
GCK
AutoCAD SHX Text
JLP
AutoCAD SHX Text
12-28-18
AutoCAD SHX Text
2
AutoCAD SHX Text
3

SCALE: NTS

J

3

PLUMBING STACK

SCALE: NTS

K

3

ROOF HATCH

SCALE: NTS

L

3

GRAVEL_RESTOR-DRAIN

SCALE: NTS

M

3

GRAVEL_RESTOR-EDGE

SCALE: NTS

N

3

GRAVEL_RESTOR-FIELD

SCALE: NTS

P

3

GRAVEL_RESTOR-FLASHING

SCALE: NTS

Q

3

GRAVEL_RESTOR-PIPE

AutoCAD SHX Text
4" MIN.
AutoCAD SHX Text
[102mm]
AutoCAD SHX Text
[305mm]
AutoCAD SHX Text
12" MIN.
AutoCAD SHX Text
WOOD DECK
AutoCAD SHX Text
SET LEAD FLANGE IN MASTIC, PRIME FLANGE BEFORE STRIPPING
AutoCAD SHX Text
HPR MODIFIED MEMBRANE FLASHING PLY 12" MIN. [305mm] ON FIELD
AutoCAD SHX Text
ALL PLIES SET IN MODIFIED COLD ADHESIVE SEE SPECIFICATIONS FOR SURFACING
AutoCAD SHX Text
BASE FLASHING PLY 8" MIN. [203mm] ON FIELD
AutoCAD SHX Text
HPR MODIFIED MEMBRANE
AutoCAD SHX Text
BASE PLY
AutoCAD SHX Text
PLUMBING VENT STACK
AutoCAD SHX Text
INSULATION, STAGGER ALL JOINTS, FASTEN PER SPECIFICATION
AutoCAD SHX Text
ROLL DOWN LEAD FLASHING 1" MIN [25mm] DOWN INTO PIPE
AutoCAD SHX Text
POLYURETHANE SEALANT
AutoCAD SHX Text
CANT FASTENED TO NAILER
AutoCAD SHX Text
ALL PLIES SET IN MODIFIED COLD ADHESIVE SEE SPECIFICATIONS FOR SURFACING
AutoCAD SHX Text
HPR MODIFIED MEMBRANE FLASHING PLY 9" MIN. [228mm] ON FIELD
AutoCAD SHX Text
BASE FLASHING PLY 6" MIN. [152mm] ON FIELD
AutoCAD SHX Text
INSULATION STAGGER ALL JOINTS, FASTEN PER SPECIFICATION
AutoCAD SHX Text
HPR MODIFIED MEMBRANE
AutoCAD SHX Text
BASE PLY
AutoCAD SHX Text
WOOD DECK
AutoCAD SHX Text
EXTERIOR LOCK PROVISION
AutoCAD SHX Text
INTERIOR HANDLE
AutoCAD SHX Text
8" MIN.
AutoCAD SHX Text
RUBBERIZED ASPHALT SEALANT
AutoCAD SHX Text
TERMINATION BAR FASTENED 8" O.C.
AutoCAD SHX Text
FASTENER WITH NEOPRENE WASHER
AutoCAD SHX Text
ANCHORS BY OTHERS
AutoCAD SHX Text
ROOF HATCH
AutoCAD SHX Text
INTEGRAL CAP FLASHING
AutoCAD SHX Text
CONTINUOUS BUTYL TAPE
AutoCAD SHX Text
BASE FLASHINGS TO BE REPLACED AND COATED
AutoCAD SHX Text
BASE FLASHINGS TO BE REPLACED AND COATED
AutoCAD SHX Text
BASE FLASHINGS TO BE REPLACED AND COATED
AutoCAD SHX Text
BASE FLASHINGS TO BE REPLACED AND COATED
AutoCAD SHX Text
BASE FLASHINGS TO BE REPLACED AND COATED
AutoCAD SHX Text
REVISION:
AutoCAD SHX Text
SHEET:
AutoCAD SHX Text
OF
AutoCAD SHX Text
DATE:
AutoCAD SHX Text
ARCHITECT:
AutoCAD SHX Text
CUSTOMER:
AutoCAD SHX Text
JOB NUMBER:
AutoCAD SHX Text
AGENT:
AutoCAD SHX Text
DWG BY:
AutoCAD SHX Text
CHK BY:
AutoCAD SHX Text
BANCROFT ELEMENTARY
AutoCAD SHX Text
2200 Parish Dr, Walnut Creek, CA 94598
AutoCAD SHX Text
GCK
AutoCAD SHX Text
JLP
AutoCAD SHX Text
12-28-18
AutoCAD SHX Text
3
AutoCAD SHX Text
3
Douglas
Text Box
Scope of Work Included but not limited to: Restoration. Indicated with (W). 1. Remove and replace all base flashings along parapet walls with new 2 ply modified system in Green-Lock Flashing Adhesive. 2. Remove and replace membrane in perimeter drainage area 5' from edge. Install new 2 ply modified system in Green-Lock Membrane Adhesive. Nail red rosin paper. Replace any insulation to match existing. 3. Remove and Replace all gutters. Strip in with new two ply modified system in Green-Lock Flashing Adhesive. 4. Power wash roof system with Simplegreen/tsp and water solution. 5. Prime roof with Garla-Block at 0.5 gallons/square. 6. Apply White-Star at 2 gallons per square. 7. Immediately embed 200lbs per square of Title 24 approved 3/8" gravel. 8. Apply Pyramic in 2 coats to all base flashings. (1.5 gallons a square per coat) 9. All conduit, vents, and hoods to be painted with district color selection. NOTE: Refer to manufacturers installation instructions and specs for complete details.
Douglas
Text Box
Bancroft ES
Douglas
Text Box
W
AutoCAD SHX Text
W
AutoCAD SHX Text
R
AutoCAD SHX Text
W
AutoCAD SHX Text
W
AutoCAD SHX Text
W
AutoCAD SHX Text
W
AutoCAD SHX Text
W
AutoCAD SHX Text
W
AutoCAD SHX Text
W
AutoCAD SHX Text
W
AutoCAD SHX Text
W
AutoCAD SHX Text
W
AutoCAD SHX Text
W
AutoCAD SHX Text
W
AutoCAD SHX Text
W
AutoCAD SHX Text
W
AutoCAD SHX Text
W
AutoCAD SHX Text
R
AutoCAD SHX Text
R
AutoCAD SHX Text
W
AutoCAD SHX Text
R
AutoCAD SHX Text
R
AutoCAD SHX Text
R
AutoCAD SHX Text
REVISION:
AutoCAD SHX Text
SHEET:
AutoCAD SHX Text
OF
AutoCAD SHX Text
DATE:
AutoCAD SHX Text
ARCHITECT:
AutoCAD SHX Text
CUSTOMER:
AutoCAD SHX Text
JOB NUMBER:
AutoCAD SHX Text
AGENT:
AutoCAD SHX Text
DWG BY:
AutoCAD SHX Text
CHK BY:
AutoCAD SHX Text
COLLEGE PARK H.S.
AutoCAD SHX Text
201 VIKING DR, PLEASANT HILL, CA 94523
AutoCAD SHX Text
GCK
AutoCAD SHX Text
JLP
AutoCAD SHX Text
12-28-18
AutoCAD SHX Text
1
AutoCAD SHX Text
3
AutoCAD SHX Text
NOTES: SCOPE OF WORK INCLUDED BUT NOT LIMITED TO: REPLACEMENT. INDICATED WITH (R) 1.REMOVE ALL ROOFING, EDGE METAL, AND REMOVE ALL ROOFING, EDGE METAL, AND GUTTERS DOWN TO STRUCTURAL DECK. 2.ADHERE 1/2" DENSDECK PRIME IN ADHERE 1/2" DENSDECK PRIME IN INSULATION ADHESIVE. TAPE ALL JOINTS. 3.INSTALL 2 PLY MODIFIED BITUMEN ROOF INSTALL 2 PLY MODIFIED BITUMEN ROOF SYSTEM IN COLD APPLIED WEATHERKING PLUS WC. 4.ALLOW ROOF TO CURE FOR 30 DAYS. ALLOW ROOF TO CURE FOR 30 DAYS. 5.APPLY GARLA-BLOCK PRIMER AT 0.5 APPLY GARLA-BLOCK PRIMER AT 0.5 GALLONS PER SQUARE. 6.APPLY WHITE-STAR AT 2 GALLONS PER APPLY WHITE-STAR AT 2 GALLONS PER SQUARE. 7.IMMEDIATELY BROADCAST TITLE 24 IMMEDIATELY BROADCAST TITLE 24 APPROVED 3/8" GRAVEL AT 200 LBS PER SQUARE. 8.ROOF TO RECEIVE NEW GUTTERS AND ROOF TO RECEIVE NEW GUTTERS AND EDGE METAL. NOTE:REFER TO MANUFACTURERS REFER TO MANUFACTURERS INSTALLATION INSTRUCTIONS FOR COMPLETE DETAILS. SCOPE OF WORK INCLUDED BUT NOT LIMITED TO: RESTORATION. INDICATED WITH (W). 1.REMOVE AND REPLACE ALL BASE REMOVE AND REPLACE ALL BASE FLASHINGS ALONG PARAPET WALLS WITH NEW 2 PLY MODIFIED SYSTEM IN GREEN-LOCK FLASHING ADHESIVE. 2.REMOVE AND REPLACE ALL GUTTERS. REMOVE AND REPLACE ALL GUTTERS. STRIP IN WITH NEW TWO PLY MODIFIED SYSTEM IN GREEN-LOCK FLASHING ADHESIVE. 3.POWER WASH ROOF SYSTEM WITH POWER WASH ROOF SYSTEM WITH SIMPLEGREEN/TSP AND WATER SOLUTION. 4.PRIME ROOF WITH GARLA-BLOCK AT 0.5 PRIME ROOF WITH GARLA-BLOCK AT 0.5 GALLONS/SQUARE. 5.APPLY WHITE-STAR AT 2 GALLONS PER APPLY WHITE-STAR AT 2 GALLONS PER SQUARE. 6.IMMEDIATELY EMBED 200LBS PER SQUARE IMMEDIATELY EMBED 200LBS PER SQUARE OF TITLE 24 APPROVED 3/8" GRAVEL. 7.APPLY PYRAMIC IN 2 COATS TO ALL BASE APPLY PYRAMIC IN 2 COATS TO ALL BASE FLASHINGS. (1.5 GALLONS A SQUARE PER COAT) 8.ALL CONDUIT, VENTS, AND HOODS TO BE ALL CONDUIT, VENTS, AND HOODS TO BE PAINTED WITH DISTRICT COLOR SELECTION. NOTE:REFER TO MANUFACTURERS REFER TO MANUFACTURERS INSTALLATION INSTRUCTIONS AND SPECS FOR COMPLETE DETAILS.
AutoCAD SHX Text
LEGEND: = SOLID HATCHED AREAS ARE N.I.C.
AutoCAD SHX Text
ROOF PLAN
AutoCAD SHX Text
N
AutoCAD SHX Text
SCALE: 1" = 70'

SCALE: NTS

H

2

ROOF DRAIN

SCALE: NTS

E

2

EQUIPMENT SUPPORT

SCALE: NTS

G

2

EXHAUST FAN DETAIL

SCALE: NTS

F

2

SKYLIGHT

SCALE: NTS

D

2

EQUIPMENT SUPPORT

SCALE: NTS

C

2

RAISED METAL EDGE

SCALE: NTS

B

2

TYPICAL - GRAVEL FINISH

SCALE: NTS

A

2

TYPICAL - COATED FINISH

AutoCAD SHX Text
WOOD DECK
AutoCAD SHX Text
INSULATION
AutoCAD SHX Text
STAGGER ALL JOINTS
AutoCAD SHX Text
FASTEN ACCORDING TO SPECIFICATION
AutoCAD SHX Text
HPR MODIFIED MEMBRANE
AutoCAD SHX Text
WITH A REFLECTIVE SURFACE
AutoCAD SHX Text
ADHESIVE
AutoCAD SHX Text
BASE PLY
AutoCAD SHX Text
SEE SPECIFICATION FOR SURFACING
AutoCAD SHX Text
ALL PLIES SET IN MODIFIED COLD ADHESIVE
AutoCAD SHX Text
RECOVERY BOARD
AutoCAD SHX Text
MODIFIED COLD
AutoCAD SHX Text
AGGREGATE SURFACE
AutoCAD SHX Text
HPR MODIFIED MEMBRANE
AutoCAD SHX Text
ALL PLIES SET IN MODIFIED COLD ADHESIVE
AutoCAD SHX Text
SEE SPECIFICATION FOR SURFACING
AutoCAD SHX Text
BASE PLY
AutoCAD SHX Text
ADHESIVE
AutoCAD SHX Text
WOOD DECK
AutoCAD SHX Text
FASTEN ACCORDING TO SPECIFICATION
AutoCAD SHX Text
STAGGER ALL JOINTS
AutoCAD SHX Text
INSULATION
AutoCAD SHX Text
RECOVERY BOARD
AutoCAD SHX Text
MODIFIED COLD
AutoCAD SHX Text
[102mm]
AutoCAD SHX Text
4" MIN.
AutoCAD SHX Text
[152mm] ON FIELD
AutoCAD SHX Text
BASE FLASHING PLY 6" MIN.
AutoCAD SHX Text
HPR MODIFIED MEMBRANE FLASHING PLY
AutoCAD SHX Text
9" MIN [228mm] ON FIELD
AutoCAD SHX Text
INSULATION STAGGER ALL JOINTS, FASTEN PER SPECIFICATION
AutoCAD SHX Text
HPR MODIFIED MEMBRANE
AutoCAD SHX Text
BASE PLY
AutoCAD SHX Text
CONTINUOUS CLEAT FASTENED 6" O.C. [152mm]
AutoCAD SHX Text
EXTEND ONE PLY OVER BLOCKING FASTEN 8" O.C. [203mm]
AutoCAD SHX Text
METAL EDGE SET IN ROOF CEMENT NAILED 3" O.C. [76mm] STAGGERED PRIME METAL FLANGE PRIOR TO STRIPPING
AutoCAD SHX Text
POLYURETHANE SEALANT
AutoCAD SHX Text
WOOD DECK
AutoCAD SHX Text
ALL PLIES SET IN MODIFIED COLD ADHESIVE SEE SPECIFICATIONS FOR SURFACING
AutoCAD SHX Text
4" MAX
AutoCAD SHX Text
24" MAX.
AutoCAD SHX Text
[610mm]
AutoCAD SHX Text
CONTINUOUS CLEAT
AutoCAD SHX Text
WITH NEOPRENE WASHERS THROUGH
AutoCAD SHX Text
SLOPE PER SPECIFICATION
AutoCAD SHX Text
FASTENERS APPROX. 24" O.C. [610mm]
AutoCAD SHX Text
METAL COPING
AutoCAD SHX Text
FASTENED 6" O.C. [152mm]
AutoCAD SHX Text
[152mm] ON FIELD
AutoCAD SHX Text
CANT STRIP
AutoCAD SHX Text
BASE FLASHING PLY 6" MIN.
AutoCAD SHX Text
HPR MODIFIED MEMBRANE FLASHING PLY
AutoCAD SHX Text
9" MIN [228mm] ON FIELD
AutoCAD SHX Text
ALL PLIES SET IN MODIFIED COLD ADHESIVE SEE SPECIFICATIONS FOR SURFACING
AutoCAD SHX Text
INSULATION STAGGER ALL JOINTS, FASTEN PER SPECIFICATION
AutoCAD SHX Text
HPR MODIFIED MEMBRANE
AutoCAD SHX Text
BASE PLY
AutoCAD SHX Text
WOOD DECK
AutoCAD SHX Text
PRE-PUNCHED ELONGATED HOLES
AutoCAD SHX Text
8" MIN.
AutoCAD SHX Text
[203mm]
AutoCAD SHX Text
INSULATION STAGGER ALL JOINTS, FASTEN PER SPECIFICATION
AutoCAD SHX Text
BASE PLY
AutoCAD SHX Text
ALL PLIES SET IN MODIFIED COLD ADHESIVE SEE SPECIFICATIONS FOR SURFACING
AutoCAD SHX Text
METAL CAP SECURED APPROX. 24" O.C. [610mm] W/ FASTENERS & NEOPRENE WASHERS
AutoCAD SHX Text
HPR MODIFIED MEMBRANE FLASHING PLY 9" MIN. [228mm] ON FIELD
AutoCAD SHX Text
BASE FLASHING PLY 6" MIN. [152mm] ON FIELD
AutoCAD SHX Text
NEOPRENE PAD
AutoCAD SHX Text
HPR MODIFIED MEMBRANE
AutoCAD SHX Text
HPR FLASHING FASTENED 8" O.C. [203mm]
AutoCAD SHX Text
BOLTS WITH NEOPRENE WASHERS
AutoCAD SHX Text
WOOD DECK
AutoCAD SHX Text
CANT FASTENED TO NAILER
AutoCAD SHX Text
2" X 10" MINIMUM [51mm X 254mm]
AutoCAD SHX Text
SKYLIGHT
AutoCAD SHX Text
METAL COUNTERFLASHING FASTENED 8" O.C. [203mm] WITH NEOPRENE WASHERS
AutoCAD SHX Text
ALL PLIES SET IN MODIFIED COLD ADHESIVE SEE SPECIFICATIONS FOR SURFACING
AutoCAD SHX Text
HPR MODIFIED MEMBRANE FLASHING PLY 9" MIN. [228mm] ON FIELD
AutoCAD SHX Text
BASE FLASHING PLY 6" MIN. [152mm] ON FIELD
AutoCAD SHX Text
EXTRUDED ALUMINUM FRAM WITH WEEP HOLES
AutoCAD SHX Text
INSULATION STAGGER ALL JOINTS, FASTEN PER SPECIFICATION
AutoCAD SHX Text
HPR MODIFIED MEMBRANE
AutoCAD SHX Text
BASE PLY
AutoCAD SHX Text
WOOD DECK
AutoCAD SHX Text
[203mm]
AutoCAD SHX Text
8" MIN.
AutoCAD SHX Text
ALL PLIES SET IN MODIFIED COLD ADHESIVE SEE SPECIFICATIONS FOR SURFACING
AutoCAD SHX Text
HPR MODIFIED MEMBRANE FLASHING PLY 9" MIN. [228mm] ON FIELD
AutoCAD SHX Text
BASE FLASHING PLY 6" MIN. [152mm] ON FIELD
AutoCAD SHX Text
HPR FLASHING FASTENED 8" O.C. [203mm]
AutoCAD SHX Text
WOOD DECK
AutoCAD SHX Text
INSULATION, STAGGER ALL JOINTS, FASTEN PER SPECIFICATIONS
AutoCAD SHX Text
HPR MODIFIED MEMBRANE
AutoCAD SHX Text
BASE PLY
AutoCAD SHX Text
METAL EXHAUST FAN COVER
AutoCAD SHX Text
CANT STRIP
AutoCAD SHX Text
WOOD DECK
AutoCAD SHX Text
DECK CLAMP
AutoCAD SHX Text
CLAMPING RING
AutoCAD SHX Text
STRAINER
AutoCAD SHX Text
ALL PLIES SET IN MODIFIED COLD ADHESIVE SEE SPECIFICATIONS FOR SURFACING
AutoCAD SHX Text
BASE FLASHING PLY 40" [1016mm]
AutoCAD SHX Text
HPR MODIFIED MEMBRANE
AutoCAD SHX Text
BASE PLY
AutoCAD SHX Text
HPR MODIFIED MEMBRANE MIN. 48" [1219mm]
AutoCAD SHX Text
TAPER INSULATION 24" MIN. [610mm] FROM CENTER OF DRAIN, STAGGER ALL JOINTS, FASTEN PER SPECIFICATION
AutoCAD SHX Text
LEAD FLASHING 30" SQ. MIN. [762] SET IN MASTIC, WRAPPED DOWN 2" MIN. [51mm], PRIME TOP SURFACE BEFORE FLASHING
AutoCAD SHX Text
REVISION:
AutoCAD SHX Text
SHEET:
AutoCAD SHX Text
OF
AutoCAD SHX Text
DATE:
AutoCAD SHX Text
ARCHITECT:
AutoCAD SHX Text
CUSTOMER:
AutoCAD SHX Text
JOB NUMBER:
AutoCAD SHX Text
AGENT:
AutoCAD SHX Text
DWG BY:
AutoCAD SHX Text
CHK BY:
AutoCAD SHX Text
COLLEGE PARK H.S.
AutoCAD SHX Text
201 VIKING DR, PLEASANT HILL, CA 94523
AutoCAD SHX Text
GCK
AutoCAD SHX Text
JLP
AutoCAD SHX Text
12-28-18
AutoCAD SHX Text
2
AutoCAD SHX Text
3

SCALE: NTS

J

3

PLUMBING STACK

SCALE: NTS

K

3

ROOF HATCH

SCALE: NTS

L

3

GRAVEL_RESTOR-DRAIN

SCALE: NTS

M

3

GRAVEL_RESTOR-EDGE

SCALE: NTS

N

3

GRAVEL_RESTOR-FIELD

SCALE: NTS

P

3

GRAVEL_RESTOR-FLASHING

SCALE: NTS

Q

3

GRAVEL_RESTOR-PIPE

AutoCAD SHX Text
4" MIN.
AutoCAD SHX Text
[102mm]
AutoCAD SHX Text
[305mm]
AutoCAD SHX Text
12" MIN.
AutoCAD SHX Text
WOOD DECK
AutoCAD SHX Text
SET LEAD FLANGE IN MASTIC, PRIME FLANGE BEFORE STRIPPING
AutoCAD SHX Text
HPR MODIFIED MEMBRANE FLASHING PLY 12" MIN. [305mm] ON FIELD
AutoCAD SHX Text
ALL PLIES SET IN MODIFIED COLD ADHESIVE SEE SPECIFICATIONS FOR SURFACING
AutoCAD SHX Text
BASE FLASHING PLY 8" MIN. [203mm] ON FIELD
AutoCAD SHX Text
HPR MODIFIED MEMBRANE
AutoCAD SHX Text
BASE PLY
AutoCAD SHX Text
PLUMBING VENT STACK
AutoCAD SHX Text
INSULATION, STAGGER ALL JOINTS, FASTEN PER SPECIFICATION
AutoCAD SHX Text
ROLL DOWN LEAD FLASHING 1" MIN [25mm] DOWN INTO PIPE
AutoCAD SHX Text
POLYURETHANE SEALANT
AutoCAD SHX Text
CANT FASTENED TO NAILER
AutoCAD SHX Text
ALL PLIES SET IN MODIFIED COLD ADHESIVE SEE SPECIFICATIONS FOR SURFACING
AutoCAD SHX Text
HPR MODIFIED MEMBRANE FLASHING PLY 9" MIN. [228mm] ON FIELD
AutoCAD SHX Text
BASE FLASHING PLY 6" MIN. [152mm] ON FIELD
AutoCAD SHX Text
INSULATION STAGGER ALL JOINTS, FASTEN PER SPECIFICATION
AutoCAD SHX Text
HPR MODIFIED MEMBRANE
AutoCAD SHX Text
BASE PLY
AutoCAD SHX Text
WOOD DECK
AutoCAD SHX Text
EXTERIOR LOCK PROVISION
AutoCAD SHX Text
INTERIOR HANDLE
AutoCAD SHX Text
8" MIN.
AutoCAD SHX Text
RUBBERIZED ASPHALT SEALANT
AutoCAD SHX Text
TERMINATION BAR FASTENED 8" O.C.
AutoCAD SHX Text
FASTENER WITH NEOPRENE WASHER
AutoCAD SHX Text
ANCHORS BY OTHERS
AutoCAD SHX Text
ROOF HATCH
AutoCAD SHX Text
INTEGRAL CAP FLASHING
AutoCAD SHX Text
CONTINUOUS BUTYL TAPE
AutoCAD SHX Text
BASE FLASHINGS TO BE REPLACED AND COATED
AutoCAD SHX Text
BASE FLASHINGS TO BE REPLACED AND COATED
AutoCAD SHX Text
BASE FLASHINGS TO BE REPLACED AND COATED
AutoCAD SHX Text
BASE FLASHINGS TO BE REPLACED AND COATED
AutoCAD SHX Text
BASE FLASHINGS TO BE REPLACED AND COATED
AutoCAD SHX Text
REVISION:
AutoCAD SHX Text
SHEET:
AutoCAD SHX Text
OF
AutoCAD SHX Text
DATE:
AutoCAD SHX Text
ARCHITECT:
AutoCAD SHX Text
CUSTOMER:
AutoCAD SHX Text
JOB NUMBER:
AutoCAD SHX Text
AGENT:
AutoCAD SHX Text
DWG BY:
AutoCAD SHX Text
CHK BY:
AutoCAD SHX Text
COLLEGE PARK H.S.
AutoCAD SHX Text
201 VIKING DR, PLEASANT HILL, CA 94523
AutoCAD SHX Text
GCK
AutoCAD SHX Text
JLP
AutoCAD SHX Text
12-28-18
AutoCAD SHX Text
3
AutoCAD SHX Text
3
Douglas
Text Box
College Park HS
Douglas
Text Box
Scope of Work Included but not limited to: Restoration. Indicated with (W). 1. Remove and replace all base flashings along parapet walls with new 2 ply modified system in Green-Lock Flashing Adhesive. 2. Remove and Replace all gutters. Strip in with new two ply modified system in Green-Lock Flashing Adhesive. 3. Power wash roof system with Simplegreen/tsp and water solution. 4. Prime roof with Garla-Block at 0.5 gallons/square. 5. Apply White-Star at 2 gallons per square. 6. Immediately embed 200lbs per square of Title 24 approved 3/8" gravel. 7. Apply Pyramic in 2 coats to all base flashings. (1.5 gallons a square per coat) 8. All conduit, vents, and hoods to be painted with district color selection. NOTE: Refer to manufacturers installation instructions and specs for complete details.
Douglas
Text Box
W
Douglas
Text Box
W
Douglas
Text Box
W
Douglas
Text Box
W
Douglas
Text Box
W
Douglas
Text Box
W
Douglas
Text Box
W
Douglas
Text Box
W
Douglas
Text Box
W
Douglas
Text Box
W
Douglas
Text Box
W
Douglas
Text Box
W
Douglas
Text Box
W
Douglas
Text Box
W
Douglas
Text Box
W
Douglas
Text Box
W
Douglas
Text Box
W
Douglas
Text Box
Scope of Work Included but not limited to: Replacement. Indicated with (R) 1. Remove all roofing, edge metal, and gutters down to structural deck. 2. Adhere 1/2" Densdeck Prime in Insulation Adhesive. Tape all joints. 3. Install 2 Ply modified bitumen roof system in cold applied Weatherking Plus WC. 4. Allow roof to cure for 30 days. 5. Apply Garla-Block Primer at 0.5 gallons per square. 6. Apply White-Star at 2 gallons per square. 7. Immediately broadcast Title 24 approved 3/8" gravel at 200 lbs per square. 8. Roof to receive new gutters and edge metal. NOTE: Refer to manufacturers installation instructions for complete details.
Douglas
Callout
R
Douglas
Callout
R
Douglas
Callout
R
Douglas
Line
Douglas
Callout
NIC
Douglas
Callout
R
Douglas
Callout
R
Douglas
Callout
R
Douglas
Rectangle
Douglas
Callout
NIC
Douglas
Callout
R
AutoCAD SHX Text
W
AutoCAD SHX Text
W
AutoCAD SHX Text
W
AutoCAD SHX Text
W
AutoCAD SHX Text
W
AutoCAD SHX Text
W
AutoCAD SHX Text
W
AutoCAD SHX Text
W
AutoCAD SHX Text
W
AutoCAD SHX Text
W
AutoCAD SHX Text
W
AutoCAD SHX Text
W
AutoCAD SHX Text
W
AutoCAD SHX Text
W
AutoCAD SHX Text
W
AutoCAD SHX Text
W
AutoCAD SHX Text
W
AutoCAD SHX Text
W
AutoCAD SHX Text
W
AutoCAD SHX Text
REVISION:
AutoCAD SHX Text
SHEET:
AutoCAD SHX Text
OF
AutoCAD SHX Text
DATE:
AutoCAD SHX Text
ARCHITECT:
AutoCAD SHX Text
CUSTOMER:
AutoCAD SHX Text
JOB NUMBER:
AutoCAD SHX Text
AGENT:
AutoCAD SHX Text
DWG BY:
AutoCAD SHX Text
CHK BY:
AutoCAD SHX Text
YGNACIO VALLEY HS
AutoCAD SHX Text
755 OAK GROVE RD. CONCORD, CA 94518
AutoCAD SHX Text
GCK
AutoCAD SHX Text
JLP
AutoCAD SHX Text
12-28-18
AutoCAD SHX Text
1
AutoCAD SHX Text
3
AutoCAD SHX Text
NOTES: SCOPE OF WORK INCLUDED BUT NOT LIMITED TO: RESTORATION. INDICATED WITH (W). 1.REMOVE AND REPLACE ALL BASE FLASHINGS ALONG PARAPET WALLS WITH NEW 2 PLY MODIFIED REMOVE AND REPLACE ALL BASE FLASHINGS ALONG PARAPET WALLS WITH NEW 2 PLY MODIFIED SYSTEM IN GREEN-LOCK FLASHING ADHESIVE. 2.REMOVE AND REPLACE MEMBRANE IN PERIMETER DRAINAGE AREA 5' FROM EDGE. INSTALL NEW 2 REMOVE AND REPLACE MEMBRANE IN PERIMETER DRAINAGE AREA 5' FROM EDGE. INSTALL NEW 2 PLY MODIFIED SYSTEM IN GREEN-LOCK MEMBRANE ADHESIVE. NAIL RED ROSIN PAPER. REPLACE ANY INSULATION TO MATCH EXISTING. 3.REMOVE AND REPLACE ALL GUTTERS. STRIP IN WITH NEW TWO PLY MODIFIED SYSTEM IN REMOVE AND REPLACE ALL GUTTERS. STRIP IN WITH NEW TWO PLY MODIFIED SYSTEM IN GREEN-LOCK FLASHING ADHESIVE. 4.POWER WASH ROOF SYSTEM WITH SIMPLEGREEN/TSP AND WATER SOLUTION. POWER WASH ROOF SYSTEM WITH SIMPLEGREEN/TSP AND WATER SOLUTION. 5.PRIME ROOF WITH GARLA-BLOCK AT 0.5 GALLONS/SQUARE. PRIME ROOF WITH GARLA-BLOCK AT 0.5 GALLONS/SQUARE. 6.APPLY WHITE-STAR AT 2 GALLONS PER SQUARE. APPLY WHITE-STAR AT 2 GALLONS PER SQUARE. 7.IMMEDIATELY EMBED 200LBS PER SQUARE OF TITLE 24 APPROVED 3/8" GRAVEL. IMMEDIATELY EMBED 200LBS PER SQUARE OF TITLE 24 APPROVED 3/8" GRAVEL. 8.APPLY PYRAMIC IN 2 COATS TO ALL BASE FLASHINGS. (1.5 GALLONS A SQUARE PER COAT) APPLY PYRAMIC IN 2 COATS TO ALL BASE FLASHINGS. (1.5 GALLONS A SQUARE PER COAT) 9.ALL CONDUIT, VENTS, AND HOODS TO BE PAINTED WITH DISTRICT COLOR SELECTION. ALL CONDUIT, VENTS, AND HOODS TO BE PAINTED WITH DISTRICT COLOR SELECTION. NOTE:REFER TO MANUFACTURERS INSTALLATION INSTRUCTIONS AND SPECS FOR COMPLETE DETAILS.REFER TO MANUFACTURERS INSTALLATION INSTRUCTIONS AND SPECS FOR COMPLETE DETAILS.
AutoCAD SHX Text
ROOF PLAN
AutoCAD SHX Text
N
AutoCAD SHX Text
SCALE: 1" = 80'
AutoCAD SHX Text
LEGEND: = SOLID HATCHED AREAS ARE N.I.C.

SCALE: NTS

H

2

ROOF DRAIN

SCALE: NTS

E

2

EQUIPMENT SUPPORT

SCALE: NTS

G

2

EXHAUST FAN DETAIL

SCALE: NTS

F

2

SKYLIGHT

SCALE: NTS

D

2

EQUIPMENT SUPPORT

SCALE: NTS

C

2

RAISED METAL EDGE

SCALE: NTS

B

2

TYPICAL - GRAVEL FINISH

SCALE: NTS

A

2

TYPICAL - COATED FINISH

AutoCAD SHX Text
WOOD DECK
AutoCAD SHX Text
INSULATION
AutoCAD SHX Text
STAGGER ALL JOINTS
AutoCAD SHX Text
FASTEN ACCORDING TO SPECIFICATION
AutoCAD SHX Text
HPR MODIFIED MEMBRANE
AutoCAD SHX Text
WITH A REFLECTIVE SURFACE
AutoCAD SHX Text
ADHESIVE
AutoCAD SHX Text
BASE PLY
AutoCAD SHX Text
SEE SPECIFICATION FOR SURFACING
AutoCAD SHX Text
ALL PLIES SET IN MODIFIED COLD ADHESIVE
AutoCAD SHX Text
RECOVERY BOARD
AutoCAD SHX Text
MODIFIED COLD
AutoCAD SHX Text
AGGREGATE SURFACE
AutoCAD SHX Text
HPR MODIFIED MEMBRANE
AutoCAD SHX Text
ALL PLIES SET IN MODIFIED COLD ADHESIVE
AutoCAD SHX Text
SEE SPECIFICATION FOR SURFACING
AutoCAD SHX Text
BASE PLY
AutoCAD SHX Text
ADHESIVE
AutoCAD SHX Text
WOOD DECK
AutoCAD SHX Text
FASTEN ACCORDING TO SPECIFICATION
AutoCAD SHX Text
STAGGER ALL JOINTS
AutoCAD SHX Text
INSULATION
AutoCAD SHX Text
RECOVERY BOARD
AutoCAD SHX Text
MODIFIED COLD
AutoCAD SHX Text
[102mm]
AutoCAD SHX Text
4" MIN.
AutoCAD SHX Text
[152mm] ON FIELD
AutoCAD SHX Text
BASE FLASHING PLY 6" MIN.
AutoCAD SHX Text
HPR MODIFIED MEMBRANE FLASHING PLY
AutoCAD SHX Text
9" MIN [228mm] ON FIELD
AutoCAD SHX Text
INSULATION STAGGER ALL JOINTS, FASTEN PER SPECIFICATION
AutoCAD SHX Text
HPR MODIFIED MEMBRANE
AutoCAD SHX Text
BASE PLY
AutoCAD SHX Text
CONTINUOUS CLEAT FASTENED 6" O.C. [152mm]
AutoCAD SHX Text
EXTEND ONE PLY OVER BLOCKING FASTEN 8" O.C. [203mm]
AutoCAD SHX Text
METAL EDGE SET IN ROOF CEMENT NAILED 3" O.C. [76mm] STAGGERED PRIME METAL FLANGE PRIOR TO STRIPPING
AutoCAD SHX Text
POLYURETHANE SEALANT
AutoCAD SHX Text
WOOD DECK
AutoCAD SHX Text
ALL PLIES SET IN MODIFIED COLD ADHESIVE SEE SPECIFICATIONS FOR SURFACING
AutoCAD SHX Text
4" MAX
AutoCAD SHX Text
24" MAX.
AutoCAD SHX Text
[610mm]
AutoCAD SHX Text
CONTINUOUS CLEAT
AutoCAD SHX Text
WITH NEOPRENE WASHERS THROUGH
AutoCAD SHX Text
SLOPE PER SPECIFICATION
AutoCAD SHX Text
FASTENERS APPROX. 24" O.C. [610mm]
AutoCAD SHX Text
METAL COPING
AutoCAD SHX Text
FASTENED 6" O.C. [152mm]
AutoCAD SHX Text
[152mm] ON FIELD
AutoCAD SHX Text
CANT STRIP
AutoCAD SHX Text
BASE FLASHING PLY 6" MIN.
AutoCAD SHX Text
HPR MODIFIED MEMBRANE FLASHING PLY
AutoCAD SHX Text
9" MIN [228mm] ON FIELD
AutoCAD SHX Text
ALL PLIES SET IN MODIFIED COLD ADHESIVE SEE SPECIFICATIONS FOR SURFACING
AutoCAD SHX Text
INSULATION STAGGER ALL JOINTS, FASTEN PER SPECIFICATION
AutoCAD SHX Text
HPR MODIFIED MEMBRANE
AutoCAD SHX Text
BASE PLY
AutoCAD SHX Text
WOOD DECK
AutoCAD SHX Text
PRE-PUNCHED ELONGATED HOLES
AutoCAD SHX Text
8" MIN.
AutoCAD SHX Text
[203mm]
AutoCAD SHX Text
INSULATION STAGGER ALL JOINTS, FASTEN PER SPECIFICATION
AutoCAD SHX Text
BASE PLY
AutoCAD SHX Text
ALL PLIES SET IN MODIFIED COLD ADHESIVE SEE SPECIFICATIONS FOR SURFACING
AutoCAD SHX Text
METAL CAP SECURED APPROX. 24" O.C. [610mm] W/ FASTENERS & NEOPRENE WASHERS
AutoCAD SHX Text
HPR MODIFIED MEMBRANE FLASHING PLY 9" MIN. [228mm] ON FIELD
AutoCAD SHX Text
BASE FLASHING PLY 6" MIN. [152mm] ON FIELD
AutoCAD SHX Text
NEOPRENE PAD
AutoCAD SHX Text
HPR MODIFIED MEMBRANE
AutoCAD SHX Text
HPR FLASHING FASTENED 8" O.C. [203mm]
AutoCAD SHX Text
BOLTS WITH NEOPRENE WASHERS
AutoCAD SHX Text
WOOD DECK
AutoCAD SHX Text
CANT FASTENED TO NAILER
AutoCAD SHX Text
2" X 10" MINIMUM [51mm X 254mm]
AutoCAD SHX Text
SKYLIGHT
AutoCAD SHX Text
METAL COUNTERFLASHING FASTENED 8" O.C. [203mm] WITH NEOPRENE WASHERS
AutoCAD SHX Text
ALL PLIES SET IN MODIFIED COLD ADHESIVE SEE SPECIFICATIONS FOR SURFACING
AutoCAD SHX Text
HPR MODIFIED MEMBRANE FLASHING PLY 9" MIN. [228mm] ON FIELD
AutoCAD SHX Text
BASE FLASHING PLY 6" MIN. [152mm] ON FIELD
AutoCAD SHX Text
EXTRUDED ALUMINUM FRAM WITH WEEP HOLES
AutoCAD SHX Text
INSULATION STAGGER ALL JOINTS, FASTEN PER SPECIFICATION
AutoCAD SHX Text
HPR MODIFIED MEMBRANE
AutoCAD SHX Text
BASE PLY
AutoCAD SHX Text
WOOD DECK
AutoCAD SHX Text
[203mm]
AutoCAD SHX Text
8" MIN.
AutoCAD SHX Text
ALL PLIES SET IN MODIFIED COLD ADHESIVE SEE SPECIFICATIONS FOR SURFACING
AutoCAD SHX Text
HPR MODIFIED MEMBRANE FLASHING PLY 9" MIN. [228mm] ON FIELD
AutoCAD SHX Text
BASE FLASHING PLY 6" MIN. [152mm] ON FIELD
AutoCAD SHX Text
HPR FLASHING FASTENED 8" O.C. [203mm]
AutoCAD SHX Text
WOOD DECK
AutoCAD SHX Text
INSULATION, STAGGER ALL JOINTS, FASTEN PER SPECIFICATIONS
AutoCAD SHX Text
HPR MODIFIED MEMBRANE
AutoCAD SHX Text
BASE PLY
AutoCAD SHX Text
METAL EXHAUST FAN COVER
AutoCAD SHX Text
CANT STRIP
AutoCAD SHX Text
WOOD DECK
AutoCAD SHX Text
DECK CLAMP
AutoCAD SHX Text
CLAMPING RING
AutoCAD SHX Text
STRAINER
AutoCAD SHX Text
ALL PLIES SET IN MODIFIED COLD ADHESIVE SEE SPECIFICATIONS FOR SURFACING
AutoCAD SHX Text
BASE FLASHING PLY 40" [1016mm]
AutoCAD SHX Text
HPR MODIFIED MEMBRANE
AutoCAD SHX Text
BASE PLY
AutoCAD SHX Text
HPR MODIFIED MEMBRANE MIN. 48" [1219mm]
AutoCAD SHX Text
TAPER INSULATION 24" MIN. [610mm] FROM CENTER OF DRAIN, STAGGER ALL JOINTS, FASTEN PER SPECIFICATION
AutoCAD SHX Text
LEAD FLASHING 30" SQ. MIN. [762] SET IN MASTIC, WRAPPED DOWN 2" MIN. [51mm], PRIME TOP SURFACE BEFORE FLASHING
AutoCAD SHX Text
REVISION:
AutoCAD SHX Text
SHEET:
AutoCAD SHX Text
OF
AutoCAD SHX Text
DATE:
AutoCAD SHX Text
ARCHITECT:
AutoCAD SHX Text
CUSTOMER:
AutoCAD SHX Text
JOB NUMBER:
AutoCAD SHX Text
AGENT:
AutoCAD SHX Text
DWG BY:
AutoCAD SHX Text
CHK BY:
AutoCAD SHX Text
YGNACIO VALLEY HS
AutoCAD SHX Text
755 OAK GROVE RD. CONCORD, CA 94518
AutoCAD SHX Text
GCK
AutoCAD SHX Text
JLP
AutoCAD SHX Text
12-28-18
AutoCAD SHX Text
2
AutoCAD SHX Text
3

SCALE: NTS

J

3

PLUMBING STACK

SCALE: NTS

K

3

ROOF HATCH

SCALE: NTS

L

3

GRAVEL_RESTOR-DRAIN

SCALE: NTS

M

3

GRAVEL_RESTOR-EDGE

SCALE: NTS

N

3

GRAVEL_RESTOR-FIELD

SCALE: NTS

P

3

GRAVEL_RESTOR-FLASHING

SCALE: NTS

Q

3

GRAVEL_RESTOR-PIPE

AutoCAD SHX Text
4" MIN.
AutoCAD SHX Text
[102mm]
AutoCAD SHX Text
[305mm]
AutoCAD SHX Text
12" MIN.
AutoCAD SHX Text
WOOD DECK
AutoCAD SHX Text
SET LEAD FLANGE IN MASTIC, PRIME FLANGE BEFORE STRIPPING
AutoCAD SHX Text
HPR MODIFIED MEMBRANE FLASHING PLY 12" MIN. [305mm] ON FIELD
AutoCAD SHX Text
ALL PLIES SET IN MODIFIED COLD ADHESIVE SEE SPECIFICATIONS FOR SURFACING
AutoCAD SHX Text
BASE FLASHING PLY 8" MIN. [203mm] ON FIELD
AutoCAD SHX Text
HPR MODIFIED MEMBRANE
AutoCAD SHX Text
BASE PLY
AutoCAD SHX Text
PLUMBING VENT STACK
AutoCAD SHX Text
INSULATION, STAGGER ALL JOINTS, FASTEN PER SPECIFICATION
AutoCAD SHX Text
ROLL DOWN LEAD FLASHING 1" MIN [25mm] DOWN INTO PIPE
AutoCAD SHX Text
POLYURETHANE SEALANT
AutoCAD SHX Text
CANT FASTENED TO NAILER
AutoCAD SHX Text
ALL PLIES SET IN MODIFIED COLD ADHESIVE SEE SPECIFICATIONS FOR SURFACING
AutoCAD SHX Text
HPR MODIFIED MEMBRANE FLASHING PLY 9" MIN. [228mm] ON FIELD
AutoCAD SHX Text
BASE FLASHING PLY 6" MIN. [152mm] ON FIELD
AutoCAD SHX Text
INSULATION STAGGER ALL JOINTS, FASTEN PER SPECIFICATION
AutoCAD SHX Text
HPR MODIFIED MEMBRANE
AutoCAD SHX Text
BASE PLY
AutoCAD SHX Text
WOOD DECK
AutoCAD SHX Text
EXTERIOR LOCK PROVISION
AutoCAD SHX Text
INTERIOR HANDLE
AutoCAD SHX Text
8" MIN.
AutoCAD SHX Text
RUBBERIZED ASPHALT SEALANT
AutoCAD SHX Text
TERMINATION BAR FASTENED 8" O.C.
AutoCAD SHX Text
FASTENER WITH NEOPRENE WASHER
AutoCAD SHX Text
ANCHORS BY OTHERS
AutoCAD SHX Text
ROOF HATCH
AutoCAD SHX Text
INTEGRAL CAP FLASHING
AutoCAD SHX Text
CONTINUOUS BUTYL TAPE
AutoCAD SHX Text
BASE FLASHINGS TO BE REPLACED AND COATED
AutoCAD SHX Text
BASE FLASHINGS TO BE REPLACED AND COATED
AutoCAD SHX Text
BASE FLASHINGS TO BE REPLACED AND COATED
AutoCAD SHX Text
BASE FLASHINGS TO BE REPLACED AND COATED
AutoCAD SHX Text
BASE FLASHINGS TO BE REPLACED AND COATED
AutoCAD SHX Text
REVISION:
AutoCAD SHX Text
SHEET:
AutoCAD SHX Text
OF
AutoCAD SHX Text
DATE:
AutoCAD SHX Text
ARCHITECT:
AutoCAD SHX Text
CUSTOMER:
AutoCAD SHX Text
JOB NUMBER:
AutoCAD SHX Text
AGENT:
AutoCAD SHX Text
DWG BY:
AutoCAD SHX Text
CHK BY:
AutoCAD SHX Text
YGNACIO VALLEY HS
AutoCAD SHX Text
755 OAK GROVE RD. CONCORD, CA 94518
AutoCAD SHX Text
GCK
AutoCAD SHX Text
JLP
AutoCAD SHX Text
12-28-18
AutoCAD SHX Text
3
AutoCAD SHX Text
3
Douglas
Text Box
Ygnacio Valley HS
Douglas
Text Box
Scope of Work Included but not limited to: Restoration. Indicated with (W). 1. Remove and replace all base flashings along parapet walls with new 2 ply modified system in Green-Lock Flashing Adhesive. 2. Remove and replace membrane in perimeter drainage area 5' from edge. Install new 2 ply modified system in Green-Lock Membrane Adhesive. Nail red rosin paper. Replace any insulation to match existing. 3. Remove and Replace all gutters. Strip in with new two ply modified system in Green-Lock Flashing Adhesive. 4. Power wash roof system with Simplegreen/tsp and water solution. 5. Prime roof with Garla-Block at 0.5 gallons/square. 6. Apply White-Star at 2 gallons per square. 7. Immediately embed 200lbs per square of Title 24 approved 3/8" gravel. 8. Apply Pyramic in 2 coats to all base flashings. (1.5 gallons a square per coat) 9. All conduit, vents, and hoods to be painted with district color selection. NOTE: Refer to manufacturers installation instructions and specs for complete details.
Douglas
Text Box
W
Douglas
Text Box
W
Douglas
Text Box
W
Douglas
Text Box
W
Douglas
Text Box
W
Douglas
Text Box
W
Douglas
Text Box
W
Douglas
Text Box
W
Douglas
Text Box
W
Douglas
Text Box
W
Douglas
Text Box
W
Douglas
Text Box
W
Douglas
Text Box
W
Douglas
Text Box
W
Douglas
Text Box
W
Douglas
Text Box
W
Douglas
Text Box
W
Douglas
Text Box
W
Douglas
Text Box
W