review a tagout prior to approval
TRANSCRIPT
ES-301 Administrative Topics Outline Form ES-301-1
Facility: V.C. Summer Unit 1 Date of Examination: 6/4/2018
Examination Level: RO SRO Operating Test Number: NRC-ILO-16-01
Administrative Topic
(see Note)
Type
Code*
Describe activity to be performed
Conduct of Operations
(A1-a) N R
JPA-102-(R)N18
2018 NRC A1-a (RO) Verification of Operator Watchstanding Certification.
Conduct of Operations
(A1-b) M R
JPA-081E-(R)N18
2018 NRC A1-b (RO) Operational Leak Rate Test without IPCS available.
Equipment Control (A2) M R
JPA-40A-(R)N18
2018 NRC A2 (RO) Review a tagout prior to approval.
Radiation Control (A3) N R
JPA-815-(R)N18
2018 NRC A3 (RO) Determine worker exposure and apply administrative exposure limit.
Emergency Plan (A4)
Not selected for RO.
NOTE: All items (five total) are required for SROs. RO applicants require only four items unless they are retaking only the administrative topics (which would require all five items).
* Type Codes & Criteria: (C)ontrol room, (S)imulator, or Class(R)oom (D)irect from bank (≤ 3 for ROs; ≤ 4 for SROs & RO retakes) (N)ew or (M)odified from bank (≥ 1) (P)revious 2 exams (≤ 1; randomly selected)
ES-301 Administrative Topics Outline Form ES-301-1
JPM SUMMARY STATEMENTS
CONDUCT OF OPERATIONS (A1-a): This is a NEW JPM. The candidate will be given a watchstanding history which will include non-licensed operator and partial licensed watches and will be required to determine the minimum number of hours, and the latest date by which they must be stood, to maintain an active license.
K/A: 2.1.4 Knowledge of individual licensed operator responsibilities related to shift staffing, such as medical requirements, “no-solo” operation, maintenance of active license status, 10cfr55, etc. (RO 3.3)
CONDUCT OF OPERATIONS (A1-b): This is a MODIFICATION of an existing JPM. The candidate will be given plant data and will be required to use a procedure to calculate an RCS leakrate.
K/A: 2.1.20 Ability to interpret and execute procedure steps. (RO 4.6)
K/A 2.1.25 Ability to interpret reference materials, such as graphs, curves, tables, etc. (RO 3.9)
VCS Task: O-002-001-02-01 PERFORM REACTOR COOLANT SYSTEM WATER
INVENTORY BALANCE
EQUIPMENT CONTROL (A2): This is a MODIFICATION of an existing JPM. The candidate will be given a completed SAP-201, Attachment VIC tagout sheet and will be required to determine the adequacy of the boundary to perform work. The candidate will be required to determine if a mode change can be performed with this tagout in place.
K/A: 2.2.13 Knowledge of tagging and clearance procedures. (RO 4.1) VCS Task: O-115-148-03-04 GENERATE TAGOUTS AND ENCLOSURES
RADIATION CONTROL (A3): This is a NEW JPM. The candidate will be given a survey map and a dose history. The candidate will locate a location which provides the least dose and determine that an extension to administrative dose limits will be required.
K/A: 2.3.4 Knowledge of radiation exposure limits under normal or emergency conditions. (RO 3.2)
VCS Task: O-119-008-04-04 APPLY RADIATION AND CONTAMINATION SAFETY
PROCEDURES
EMERGENCY PLAN (A4): Not selected for RO.
ES-301 Administrative Topics Outline Form ES-301-1
Facility: V.C. Summer Unit 1 Date of Examination: 6/4/2018
Examination Level: RO SRO Operating Test Number: NRC-ILO-16-01
Administrative Topic (see
Note)
Type
Code*
Describe activity to be performed
Conduct of Operations
(A1-a) N R
JPA-102-(S)N18
2018 NRC A1-a (SRO) Verification of Senior Licensed Operator watchstanding Certification.
Conduct of Operations
(A1-b) N R
JPA-135-(S)N18
2018 A1-b (SRO) Determine reportability requirements.
Equipment Control (A2) N R
JPA-041B-(S)N18
2018 A2 (SRO) Evaluate the operational impact of a change in EOOS Status.
Radiation Control (A3) P D R
JPA-190-(S)N18
2018 A3 (SRO) Review a release permit prior to approval/ release
Emergency Plan (A4) N R
JPA-1008-(S)N18
2018 A4 (SRO) Determine Protective Action Recommendations
NOTE: All items (five total) are required for SROs. RO applicants require only four items unless they are retaking only the administrative topics (which would require all five items).
* Type Codes & Criteria: (C)ontrol room, (S)imulator, or Class(R)oom (D)irect from bank (≤ 3 for ROs; ≤ 4 for SROs & RO retakes) (N)ew or (M)odified from bank (≥ 1) (P)revious 2 exams (≤ 1; randomly selected)
ES-301 Administrative Topics Outline Form ES-301-1
JPM SUMMARY STATEMENTS
CONDUCT OF OPERATIONS (A1-a): This is a NEW JPM. The candidate will be given watchstanding history for three licensed SROs and determine which met the requirements for maintaining an active license.
K/A: 2.1.4 Knowledge of individual licensed operator responsibilities related to shift staffing, such as medical requirements, “no-solo” operation, maintenance of active license status, 10CFR55, etc. (SRO 3.8)
VCS Task: O-341-038-03-02 INTERPRET AND ENSURE COMPLIANCE WITH PLANT
ADMINISTRATIVE PROCEDURES DURING NORMAL AND OFF NORMAL PLANT OPERATIONS.
CONDUCT OF OPERATIONS (A1-b): This is NEW JPM. The candidate will be given a scenario in which a Feedwater trips and an Emergency Feedwater actuation occurs. The candidate will be required to determine the site reportability requirement and who in management must be apprised of the event.
K/A: 2.1.18 Ability to make accurate, clear, and concise logs, records, status boards, and reports. (SRO 3.8)
VCS Task: O-341-013-03-02 REPORT SAFETY LIMIT VIOLATIONS AND REPORTABLE
OCCURRENCES PER NL-122
EQUIPMENT CONTROL (A2): This is a NEW JPM. The candidate will be given a IPCS screen shot of EOOS and determine that a Yellow FEP risk exists due to a tagout of “C” Service Water Pump. The candidate will then determine that a requirement exists to place the unit in Hot Standby if the pump cannot be restored to service within 30 days.
K/A: 2.2.17 Knowledge of the process for managing maintenance activities during power operations, such as risk assessments, work prioritization, and coordination with the transmission system operator. (SRO 4.3)
VCS Task: O-342-002-03-02 COORDINATE PLANT OPERATION TO SUPPORT
MAINTENANCE ACTIVITIES.
ES-301 Administrative Topics Outline Form ES-301-1 RADIATION CONTROL (A3): This JPM is a BANK JPM used on the 2017 NRC exam. The candidate will be given a partially completed SOP-119, ATTACHMENT VA release work sheet and HPP-709, ATTACHMENT I, Gaseous Waste Release Permit and will determine the conditions that prevent commencing the release.
K/A: 2.3.6 Ability to approve release permits. (SRO 3.8) VCS Task: O-341-012-03-02 APPROVE RADIOACTIVE WASTE DISCHARGE/RELEASE
PERMITS (HPP-709 AND HPP-710)
EMERGENCY PLAN (A4): This is a NEW JPM. The candidate will be given conditions in a General Emergency that include a Hostile Action and will determine the required Protective Action Recommendations.
K/A: 2.4.40 Knowledge of the SRO's responsibilities in emergency plan implementation. (SRO 4.5
VCS Task: O-344-003-03-02 PERFORM REQUIRED NOTIFICATIONS OF ON-SITE AND
OFF-SITE PERSONNEL FOR ABNORMAL EVENTS
ES-301 Control Room/In-Plant Systems Outline Form Form ES-301-2
- Facility: _____V.C.Summer Unit 1 Date of Examination: 6/4/2018_
Exam Level: RO SRO-I SRO-U Operating Test No: NRC-ILO-16-01
Control Room Systems:* 8 for RO; 7 for SRO-I; 2 or 3 for SRO-U
System / JPM Title Type Code* Safety
Function
a. System 006: Emergency Core Cooling System (ECCS) (JPS-001F-N18)
Manually actuate Safety Injection and perform EOP-1.0, E-0 Attachment 3 following a Small Break LOCA with failure of both Charging pumps to start.
N,A,EN,L,S 2
b.
APE027: Pressurizer Pressure Control System (PZR PCS) Malfunction (JPS-002F-N18)
Stop RCPs per EOP-1.1, ES-0.1 to mitigate a stuck open PZR spray valve following a reactor trip.
M,A,L,S 3
c.
EPE074: Inadequate Core Cooling (JPS-003F-N18)
Start RCPs in EOP-14.0, FR-C.1 due to core exit temperature greater than 1200°F. No RCP can be started and all PZR PORVs and Reactor Head vent valves are opened.
D,A,L,S 4P
d.
W/E 13: Steam Generator Overpressure (JPS-004-N18)
Respond to Steam Generator Overpressure per EOP-15.1, FR-H.2. Must use SG PORVs since the condenser is not available.
D,L,P,S 4S
e. System 062: A.C. Electrical Distribution (JPS-005-N18)
Restore an ESF bus using transformer XTF-5052 and procedure SOP-304 as referenced by EOP-6.0, ECA-0.0, during a loss of all ESF AC power.
N,L,S 6
f. System 015: Nuclear Instrumentation System (JPS-006-N18)
Respond to power range Instrumentation channel N-44 fail low with rod control in automatic.
D,S 7
g. System 008: Component Cooling Water System (JPS-007-N18)
Swap active CCW loops during normal full power operations. M,S 8
h W/E 16: High Containment Radiation (JPS-008F-N18)
Align RB HEPA filters using EOP-17.2 following a high containment radiation condition post LOCA.
D,EN,A,L,P,S 9
In-Plant Systems* (3 for RO); (3 for SRO-I); (3 or 2 for SRO-U)
i System 001: Control Rod Drive System (JPP-0009F-N18)
Locally Trip the Reactor using EOP-13.0, FR-S.1. The trip breakers don’t open locally requiring MG set motor breakers to be opened locally.
D,A,E 1
j
APE040; Steam Line Rupture (JPP-010-N18)
Locally de-energize and close MS Loop “B” and “C“ supplies to the Turbine Driven Emergency Feedwater Pump per EOP-3.0, E-2.
D,E,L,P 4S
k System 033: Spent Fuel Pool Cooling System (JPP-011-N18)
Fill Spent Fuel Pool using Rx M/U water in accordance with SOP-123. N,R 8
ES-301 Control Room/In-Plant Systems Outline Form Form ES-301-2
* All RO and SRO-I control room (and in-plant) systems must be different and serve different safety functions; all five SRO-U systems must serve different safety functions; in-plant systems and functions may overlap those tested in the control room.
* Type Codes Criteria for RO / SRO-I / SRO-U RO
(A)lternate path 4-6 / 4-6 / 2-3 5
(C)ontrol room
(D)irect from bank ≤ 9 / ≤ 8 / ≤ 4 6
(E)mergency or abnormal in-plant ≥ 1 / ≥ 1 / ≥ 1 2
(EN)gineered safety feature ≥ 1 / ≥ 1 / ≥ 1 (control room system) 2
(L)ow-Power / Shutdown ≥ 1 / ≥ 1 / ≥ 1 7
(N)ew or (M)odified from bank including 1(A) ≥ 2 / ≥ 2 / ≥ 1 5
(P)revious 2 exams ≤ 3 / ≤ 3 / ≤ 2 (randomly selected) 3
(R)CA ≥ 1 / ≥ 1 / ≥ 1 1
(S)imulator
VC SUMMER NRC RO JPM SUMMARY a. This is a new JPM. This JPM starts with the plant having just experienced a Small Break LOCA
and a failure of Safety Injection to actuate automatically. The Candidate will be told that immediate actions of EOP-1.0, E-0 Reactor Trip or Safety Injection have been completed through step 3 and they are to commence by performing immediate action 4. They will determine that Safety Injection is required and will manually actuate Safety Injection and then will perform EOP-1.0, Attachment 3, SI Equipment Verification. Train “A” Safety Injection will actuate and Train B Safety Injection will not actuate. The Train “A” Charging/SI pump will experience a sheared shaft while the Train B Charging/SI pump will not start due to the Train “B” SI fail to actuate. The Candidate must manually align Train “B” equipment and it will be critical for them to start the Train “B” Charging/SI pump. The JPM is considered alternate path due to the failure of Train “B” equipment to start in response to the Safety Injection signal which will require the operator to take manual action.
K/A000006A2.12: Ability to (a) predict the impacts of the following malfunctions or operations on the ECCS; and (b) based on those predictions, use procedures to correct, control, or mitigate the consequences of those malfunctions or operations: Conditions requiring actuation of ECCS. (RO 4.5 SRO 4.8)
NUREG 1122 System: 006, Emergency Core Cooling System (ECCS)
VCS Task: O-006-013-01-01, MANUALLY INITIATE SAFETY INJECTION
ES-301 Control Room/In-Plant Systems Outline Form Form ES-301-2
b. This is a modified bank JPM. The JPM begins with the plant having tripped from 100%
power. The Candidate will be told that the crew have transitioned to EOP-1.1, ES-0.1 Reactor Trip Response and have completed steps 1 through 7. The initiating cue to the Candidate will be to perform EOP-1.1 beginning at step 8, verify all Control Rods are fully inserted. Once the Candidate commences the performance of EOP-1.1 PZR spray valve PCV-444C will fail partially open causing PZR pressure to slowly lower. The Candidate will recognize PZR pressure is not stable or trending to 2230 psig at step 11 and will take alternative action beginning with a check of PZR PORVs closed and a check that PZR spray valves are closed. Attempts to close Spray valve PCV-444C will be unsuccessful and the Candidate will stop the “A” RCP and then will stop the “C” RCP. The JPM is considered alternate path due to the failure of the Pressurizer Spray valves to close when the operator attempts to close them which requires the stopping of RCPs.
K/A 027AA1.01: Ability to operate and/or monitor the following as they apply to the Pressurizer Pressure Control Malfunctions: PZR heaters, sprays, and PORVs. (RO 4.0 SRO 3.9)
NUREG 1122 APE: 027, Pressurizer Pressure Control System (PZR PCS) Malfunction.
VCS Task: O-000-509-05-02, RECOVER FROM REACTOR TRIP PER EOP-1.1
c. This is a bank JPM. Initial conditions for the JPM are a LOCA with a red path condition on the Core Cooling critical safety function and EOP-14.0, FR-C.1 RESPONSE TO INADEQUATE CORE COOLING in progress. The Candidate will receive the initiating cue to perform Step 22 of EOP-14.0, check if RCPs should be started. The Narrow Range level in the Steam Generators will only support start of the “A” RCP. The “A” RCP will fail to start and the Candidate must apply Alternative Actions and open all PZR PORVs and Reactor Head Vent valves. The JPM is considered alternate path because the available RCP fails to start which requires opening of RCS vents in order to stimulate some core cooling.
K/A 074EA1.05: Ability to operate and monitor the following as they apply to Inadequate Core Cooling: PORV. (RO 4.3 SRO 4.1)
NUREG 1122 EPE: 074, Inadequate Core Cooling.
VCS Task: O-000-088-05-01, RESPONSE TO INADEQUATE CORE COOLING PER SOP-122/EOP-12.0/EOP-2.0/EOP-14.0.
d. This is a revised bank JPM. Initial conditions for the JPM are reactor tripped from 100% power and a yellow path condition exists on the heat sink critical safety function. The Candidate will receive the initiating cue to implement EOP-15.1, FR-H.2 RESPONSE TO STEAM GENERATOR OVERPRESSURE. The candidate uses EOP-15.1 to address high pressure in the “B” SG. The feedwater flow isolation valves to the “B” SG failed to close automatically and will require the operator to close at least one valve to prevent potential SG overfill. The candidate will then proceed to depressurize the “B” Steam Generator using the SG PORV and will then control RCS temperature according to EOP-1.1, ES-0.1 REACTOR TRIP RESPONSE.
K/A W/E13EA1.1: Ability to operate and/or monitor the following as they apply to the (Steam Generator Overpressure): Components, and functions of control and safety systems, including instrumentation, signals, interlocks, failure modes, and automatic and manual features. (RO: 3.1, SRO: 3.3)
K/A W/E13EA2.1: Ability to determine and interpret the following as they apply to the (Steam Generator Overpressure): Facility conditions and selection of appropriate procedures during abnormal and emergency operations. (RO 2.9 SRO 3.4)
NUREG 1122 W/E: E13, Steam Generator Overpressure.
VCS Task: O-000-092-05-01, RESPOND TO STEAM GENERATOR OVERPRESSURE
ES-301 Control Room/In-Plant Systems Outline Form Form ES-301-2
PER EOP-15.1/EOP-12.0.
e. This is a new JPM. The JPM begins with both 7.2 KV ESF Safety Busses de-energized. The Train “B” bus is faulted and the Train “A” Diesel Generator failed to start either automatically or manually. A single offsite power source is available. The Candidate will be directed by the CRS to restore power to the Train “A” ESF bus using the 13.8 KV Parr Hydro line and XTF-5052. The Candidate will be directed to use SOP-304, 115KV/7.2KV OPERATIONS in accordance with the alternative action step 6.a of EOP-6.0, ECA-0.0 LOSS OF ALL ESF AC POWER. The candidate will align the Parr Hydro 13.8 KV line via XTF-5052 to energize the Train “A” ESF bus.
K/A000062A2.05: Ability to (a) predict the impacts of the following malfunctions or operations on the ac distribution system; and (b) based on those predictions, use procedures to correct, control, or mitigate the consequences of those malfunctions or operations: Methods for energizing a dead bus (RO 2.9 SRO 3.3)
NUREG 1122 System: 062, AC Electrical Distribution
VCS Task: O-000-055-05-01, RESPOND TO LOSS OF OFF SITE AND ON SITE POWER
f. This is a revision to a bank JPM. Initial conditions are 75% power all controls in automatic. The Candidate will be directed to respond to any developing plant conditions. Power Range NI channel N-44 will fail low causing auto rod withdrawal. The candidate will place rods in Manual and proceed to remove N-44 from service using AOP-401.10, POWER RANGE CHANNEL FAILURE.
K/A 000015A2.01: Ability to (a) predict the impacts of the following malfunctions or operations on the NIS; and (b) based on those predictions, use procedures to correct, control, or mitigate the consequences of those malfunctions or operations: Power supply loss or erratic operation. (RO 3.5, SRO 3.9)
NUREG 1122 System: 015, Nuclear Instrumentation System.
VCS Task: O-000-034-05-01, RESPOND TO POWER RANGE INSTUMENTATION CHANNEL FAILURE
g. This is a modified bank JPM. The initial conditions for this JPM have the “C” CCW Pump aligned to Train “B” in preparation for swapping the active loop from Train “A” to Train “B” using SOP-118 COMPONENT COOLING WATER. The Candidate will place the “B” CCW Pump in service then perform valve manipulations to remove flow from the “B” RHR Heat Exchanger and the Train “A” non-essential header and to align flow to the Train “B” non-essential header The critical steps are Starting the “B” CCW pump, closing flow to the “B” RHR Heat exchanger and aligning the non-essential header to Train “B” only.
K/A 000008A4.01: Ability to manually operate and/or monitor in the control room: CCW indications and controls (RO: 3.3, SRO: 3.1)
NUREG 1122 System: 008, Component Cooling Water System (CCWS)
VCS Task: O-008-021-01-01 SWITCH COMPONENT COOLING WATER TRAINS PER SOP-117/SOP-118/SOP-501
ES-301 Control Room/In-Plant Systems Outline Form Form ES-301-2
h. This is a bank JPM that has been revised. The initial conditions for this JPM are a yellow path
condition on the Containment Critical safety function due to high radiation levels following a DBA LOCA. The CRS will direct the Candidate to implement EOP-17.2, RESPONSE TO HIGH REACTOR BUILDING RADIATION LEVEL. The Candidate will place all RBCU HEPA filter dampers in the filter position but XDP-110A, RBCU 64A HEPA and XDP-111B, RBCU 65B HEPA Filter Bypass Dampers will remain in the bypassed position. The 64A RBCU fan will be running thus the Candidate will be required to start the 65A RBCU. In addition the 64B RBCU failed to auto start and will require the operator to stop the 64B Normal fan and manually start the 64B slow fan to assure adequate HEPA filtration in service. The JPM is considered alternate path because the HEPA filters fail to properly align which requires the operator to take manual action to align filtration.
K/A W/E16EA1.1: Ability to operate and/or monitor the following as they apply to the (High Containment Radiation): Components, and functions of control and safety systems, including instrumentation, signals, interlocks, failure modes, and automatic and manual features. (RO 3.1 SRO 3.2)
NUREG 1122 W/E: E16, High Containment Radiation.
VCS Task: O-311-018-06-01, RESPONSE TO HIGH RB RADIATION.
i. This is a bank JPM. The initial conditions for this JPM are an ATWS. The CRS will direct the Candidate to implement EOP-13.0, FR-S.1 RESPONSE TO ABNORMAL NUCLEAR POWER GENERATION, Attachment 1-TRIPPING THE REACTOR LOCALLY. The Candidate will attempt to locally open the Reactor Trip and Bypass breakers but they will not open. Next the Candidate will attempt to open Rod Drive MG set motor and generator breakers and they also will not open. Finally the Candidate will open the 480 volt supply breakers to both Rod Drive MG set motors. The JPM is considered alternate path because the action to locally open Reactor Trip breakers fails which requires the Candidate to open the MG set motor supply breakers.
K/A 029EA1.12: Knowledge of the reasons for the following responses as they apply to the ATWS: Actions contained in EOP for ATWS (RO 4.4 SRO 4.7)
K/A 029EA1.12: Ability to operate and monitor the following as they apply to a ATWS: M/G set power supply and reactor trip breakers (RO 4.1 SRO 4.0)
NUREG 1122 EPE: 029, Anticipated Transient Without Scram (ATWS)
VCS Task: O-000-117-05-04 RESPOND TO ABNORMAL NUCLEAR POWER GENERATION
j. This is a bank JPM. This JPM was randomly selected and was last used in the 2016 NRC exam. The Candidate will be directed to de-energize and locally close and the MS Loop “B” and “C” supplies to the turbine driven Emergency Feedwater pump in accordance with EOP-3.0, E-2 FAULTED STEAM GENERATOR ISOLATION.
K/A: 040AA1.10: Ability to operate and/or monitor the following as they apply to the Steam Line Rupture: AFW system (RO: 4.1, SRO: 4.1)
NUREG 1122 APE: 040, Steam Line Rupture.
VCS Task: O-000-169-05-04, LOCALLY ISOLATE A FAULTED STEAM GENERATOR PER EOP-3.0.
ES-301 Control Room/In-Plant Systems Outline Form Form ES-301-2
k. This is a new JPM. The initial conditions for the JPM are 100% power with Spent Fuel Pool level at 461.1 ft., which is below the Tech Spec 3.7.10 limit in accordance with OAP-106.1, OPERATING ROUNDS. The candidate will be directed to raise Spent Fuel Pool level to 461.8 ft using SOP-123, SPENT FUEL COOLING SYSTEM. The Candidate will simulate lining up the Reactor Makeup Water flowpath to the Spent Fuel Pool and will raise level to the desired value.
K/A: 000033A1.01: Ability to predict and/or monitor changes in parameters (to prevent exceeding design limits) associated with Spent Fuel Pool Cooling System operating the controls including: Spent Fuel Pool Water Level (RO: 2.7, SRO: 3.3)
NUREG 1122 System: 033, Spent Fuel Pool Cooling System.
VCS Task: O-033-002-01-04, MAKEUP TO THE SPENT FUEL POOL PER SOP-123.
ES-301 Control Room/In-Plant Systems Outline Form Form ES-301-2
Facility: _____V.C.Summer Unit 1 Date of Examination: 6/4/2018
Exam Level: RO SRO-I SRO-U Operating Test No: NRC-ILO-16-01
Control Room Systems:* 8 for RO; 7 for SRO-I; 2 or 3 for SRO-U
System / JPM Title Type Code* Safety
Function
a. System 006: Emergency Core Cooling System (ECCS) (JPS-001F-N18)
Manually actuate Safety Injection and perform EOP-1.0, E-0 Attachment 3 following a Small Break LOCA with failure of both Charging pumps to start.
N,A,EN,L,S 2
b.
APE027: Pressurizer Pressure Control System (PZR PCS) Malfunction (JPS-002F-N18)
Stop RCPs per EOP-1.1, ES-0.1 to mitigate a stuck open PZR spray valve following a reactor trip.
M,A,L,S 3
c.
EPE074: Inadequate Core Cooling (JPS-003F-N18)
Start RCPs in EOP-14.0, FR-C.1 due to core exit temperature greater than 1200°F. No RCP can be started and all PZR PORVs and Reactor Head vent valves are opened.
D,A,L,S 4P
d.
W/E 13: Steam Generator Overpressure (JPS-004-N18)
Respond to Steam Generator Overpressure per EOP-15.1, FR-H.2. Must use SG PORVs since the condenser is not available.
D,L,P,S 4S
e. System 062: A.C. Electrical Distribution (JPS-005-N18)
Restore an ESF bus using transformer XTF-5052 and procedure SOP-304 as referenced by EOP-6.0, ECA-0.0, during a loss of all ESF AC power.
N,L,S 6
f. System 015: Nuclear Instrumentation System (JPS-006-N18)
Respond to power range Instrumentation channel N-44 fail low with rod control in automatic.
D,S 7
g. Not for SRO-I use. NA NA
h W/E 16: High Containment Radiation (JPS-008F-N18)
Align RB HEPA filters using EOP-17.2 following a high containment radiation condition post LOCA.
D,EN,A,L,P,S 9
In-Plant Systems* (3 for RO); (3 for SRO-I); (3 or 2 for SRO-U)
i System 001: Control Rod Drive System (JPP-0009F-N18)
Locally Trip the Reactor using EOP-13.0, FR-S.1. The trip breakers don’t open locally requiring MG set motor breakers to be opened locally.
D,A,E 1
j
APE040; Steam Line Rupture (JPP-010-N18) Locally de-energize and close MS Loop “B” and “C“ supplies to the Turbine Driven Emergency Feedwater Pump per EOP-3.0, E-2.
D,E,L,P 4S
k System 033: Spent Fuel Pool Cooling System (JPP-011-N18)
Fill Spent Fuel Pool using Rx M/U water in accordance with SOP-123. N,R 8
ES-301 Control Room/In-Plant Systems Outline Form Form ES-301-2
* All RO and SRO-I control room (and in-plant) systems must be different and serve different safety functions; all five SRO-U systems must serve different safety functions; in-plant systems and functions may overlap those tested in the control room.
* Type Codes Criteria for RO / SRO-I / SRO-U SRO-I
(A)lternate path 4-6 / 4-6 / 2-3 5
(C)ontrol room
(D)irect from bank ≤ 9 / ≤ 8 / ≤ 4 6
(E)mergency or abnormal in-plant ≥ 1 / ≥ 1 / ≥ 1 2
(EN)gineered safety feature ≥ 1 / ≥ 1 / ≥ 1 (control room system) 2
(L)ow-Power / Shutdown ≥ 1 / ≥ 1 / ≥ 1 7
(N)ew or (M)odified from bank including 1(A) ≥ 2 / ≥ 2 / ≥ 1 4
(P)revious 2 exams ≤ 3 / ≤ 3 / ≤ 2 (randomly selected) 3
(R)CA ≥ 1 / ≥ 1 / ≥ 1 1
(S)imulator
VC SUMMER NRC RO JPM SUMMARY
a. This is a new JPM. This JPM starts with the plant having just experienced a Small Break LOCA and a failure of Safety Injection to actuate automatically. The Candidate will be told that immediate actions of EOP-1.0, E-0 Reactor Trip or Safety Injection have been completed through step 3 and they are to commence by performing immediate action 4. They will determine that Safety Injection is required and will manually actuate Safety Injection and then will perform EOP-1.0, Attachment 3, SI Equipment Verification. Train “A” Safety Injection will actuate and Train B Safety Injection will not actuate. The Train “A” Charging/SI pump will experience a sheared shaft while the Train B Charging/SI pump will not start due to the Train “B” SI fail to actuate. The Candidate must manually align Train “B” equipment and it will be critical for them to start the Train “B” Charging/SI pump. The JPM is considered alternate path due to the failure of Train “B” equipment to start in response to the Safety Injection signal which will require the operator to take manual action.
K/A000006A2.12: Ability to (a) predict the impacts of the following malfunctions or operations on the ECCS; and (b) based on those predictions, use procedures to correct, control, or mitigate the consequences of those malfunctions or operations: Conditions requiring actuation of ECCS. (RO 4.5 SRO 4.8)
NUREG 1122 System: 006, Emergency Core Cooling System (ECCS)
VCS Task: O-006-013-01-01, MANUALLY INITIATE SAFETY INJECTION
ES-301 Control Room/In-Plant Systems Outline Form Form ES-301-2
b. This is a modified bank JPM. The JPM begins with the plant having tripped from 100%
power. The Candidate will be told that the crew have transitioned to EOP-1.1, ES-0.1 Reactor Trip Response and have completed steps 1 through 7. The initiating cue to the Candidate will be to perform EOP-1.1 beginning at step 8, verify all Control Rods are fully inserted. Once the Candidate commences the performance of EOP-1.1 PZR spray valve PCV-444C will fail partially open causing PZR pressure to slowly lower. The Candidate will recognize PZR pressure is not stable or trending to 2230 psig at step 11 and will take alternative action beginning with a check of PZR PORVs closed and a check that PZR spray valves are closed. Attempts to close Spray valve PCV-444C will be unsuccessful and the Candidate will stop the “A” RCP and then will stop the “C” RCP. The JPM is considered alternate path due to the failure of the Pressurizer Spray valves to close when the operator attempts to close them which requires the stopping of RCPs.
K/A 027AA1.01: Ability to operate and/or monitor the following as they apply to the Pressurizer Pressure Control Malfunctions: PZR heaters, sprays, and PORVs. (RO 4.0 SRO 3.9)
NUREG 1122 APE: 027, Pressurizer Pressure Control System (PZR PCS) Malfunction.
VCS Task: O-000-509-05-02, RECOVER FROM REACTOR TRIP PER EOP-1.1
c. This is a bank JPM. Initial conditions for the JPM are a LOCA with a red path condition on the Core Cooling critical safety function and EOP-14.0, FR-C.1 RESPONSE TO INADEQUATE CORE COOLING in progress. The Candidate will receive the initiating cue to perform Step 22 of EOP-14.0, check if RCPs should be started. The Narrow Range level in the Steam Generators will only support start of the “A” RCP. The “A” RCP will fail to start and the Candidate must apply Alternative Actions and open all PZR PORVs and Reactor Head Vent valves. The JPM is considered alternate path because the available RCP fails to start which requires opening of RCS vents in order to stimulate some core cooling.
K/A 074EA1.05: Ability to operate and monitor the following as they apply to Inadequate Core Cooling: PORV. (RO 4.3 SRO 4.1)
NUREG 1122 EPE: 074, Inadequate Core Cooling.
VCS Task: O-000-088-05-01, RESPONSE TO INADEQUATE CORE COOLING PER SOP-122/EOP-12.0/EOP-2.0/EOP-14.0.
d. This is a revised bank JPM. Initial conditions for the JPM are reactor tripped from 100% power and a yellow path condition exists on the heat sink critical safety function. The Candidate will receive the initiating cue to implement EOP-15.1, FR-H.2 RESPONSE TO STEAM GENERATOR OVERPRESSURE. The candidate uses EOP-15.1 to address high pressure in the “B” SG. The feedwater flow isolation valves to the “B” SG failed to close automatically and will require the operator to close at least one valve to prevent potential SG overfill. The candidate will then proceed to depressurize the “B” Steam Generator using the SG PORV and will then control RCS temperature according to EOP-1.1, ES-0.1 REACTOR TRIP RESPONSE.
K/A W/E13EA1.1: Ability to operate and/or monitor the following as they apply to the (Steam Generator Overpressure): Components, and functions of control and safety systems, including instrumentation, signals, interlocks, failure modes, and automatic and manual features. (RO: 3.1, SRO: 3.3)
K/A W/E13EA2.1: Ability to determine and interpret the following as they apply to the (Steam Generator Overpressure): Facility conditions and selection of appropriate procedures during abnormal and emergency operations. (RO 2.9 SRO 3.4)
NUREG 1122 W/E: E13, Steam Generator Overpressure.
VCS Task: O-000-092-05-01, RESPOND TO STEAM GENERATOR OVERPRESSURE PER EOP-15.1/EOP-12.0.
ES-301 Control Room/In-Plant Systems Outline Form Form ES-301-2
e. This is a new JPM. The JPM begins with both 7.2 KV ESF Safety Busses de-energized. The
Train “B” bus is faulted and the Train “A” Diesel Generator failed to start either automatically or manually. A single offsite power source is available. The Candidate will be directed by the CRS to restore power to the Train “A” ESF bus using the 13.8 KV Parr Hydro line and XTF-5052. The Candidate will be directed to use SOP-304, 115KV/7.2KV OPERATIONS in accordance with the alternative action step 6.a of EOP-6.0, ECA-0.0 LOSS OF ALL ESF AC POWER. The candidate will align the Parr Hydro 13.8 KV line via XTF-5052 to energize the Train “A” ESF bus.
K/A000062A2.05: Ability to (a) predict the impacts of the following malfunctions or operations on the ac distribution system; and (b) based on those predictions, use procedures to correct, control, or mitigate the consequences of those malfunctions or operations: Methods for energizing a dead bus (RO 2.9 SRO 3.3)
NUREG 1122 System: 062, AC Electrical Distribution
VCS Task: O-000-055-05-01, RESPOND TO LOSS OF OFF SITE AND ON SITE POWER
f. This is a revision to a bank JPM. Initial conditions are 75% power all controls in automatic. The Candidate will be directed to respond to any developing plant conditions. Power Range NI channel N-44 will fail low causing auto rod withdrawal. The candidate will place rods in Manual and proceed to remove N-44 from service using AOP-401.10, POWER RANGE CHANNEL FAILURE.
K/A 000015A2.01: Ability to (a) predict the impacts of the following malfunctions or operations on the NIS; and (b) based on those predictions, use procedures to correct, control, or mitigate the consequences of those malfunctions or operations: Power supply loss or erratic operation. (RO 3.5, SRO 3.9)
NUREG 1122 System: 015, Nuclear Instrumentation System.
VCS Task: O-000-034-05-01, RESPOND TO POWER RANGE INSTUMENTATION CHANNEL FAILURE
g. Not for SRO-I use.
h. This is a bank JPM that has been revised. The initial conditions for this JPM are a yellow path condition on the Containment Critical safety function due to high radiation levels following a DBA LOCA. The CRS will direct the Candidate to implement EOP-17.2, RESPONSE TO HIGH REACTOR BUILDING RADIATION LEVEL. The Candidate will place all RBCU HEPA filter dampers in the filter position but XDP-110A, RBCU 64A HEPA and XDP-111B, RBCU 65B HEPA Filter Bypass Dampers will remain in the bypassed position. The 64A RBCU fan will be running thus the Candidate will be required to start the 65A RBCU. In addition the 64B RBCU failed to auto start and will require the operator to stop the 64B Normal fan and manually start the 64B slow fan to assure adequate HEPA filtration in service. The JPM is considered alternate path because the HEPA filters fail to properly align which requires the operator to take manual action to align filtration.
K/A W/E16EA1.1: Ability to operate and/or monitor the following as they apply to the (High Containment Radiation): Components, and functions of control and safety systems, including instrumentation, signals, interlocks, failure modes, and automatic and manual features. (RO 3.1 SRO 3.2)
NUREG 1122 W/E: E16, High Containment Radiation.
VCS Task: O-311-018-06-01, RESPONSE TO HIGH RB RADIATION.
ES-301 Control Room/In-Plant Systems Outline Form Form ES-301-2
i. This is a bank JPM. The initial conditions for this JPM are an ATWS. The CRS will direct the Candidate to implement EOP-13.0, FR-S.1 RESPONSE TO ABNORMAL NUCLEAR POWER GENERATION, Attachment 1-TRIPPING THE REACTOR LOCALLY. The Candidate will attempt to locally open the Reactor Trip and Bypass breakers but they will not open. Next the Candidate will attempt to open Rod Drive MG set motor and generator breakers and they also will not open. Finally the Candidate will open the 480 volt supply breakers to both Rod Drive MG set motors. The JPM is considered alternate path because the action to locally open Reactor Trip breakers fails which requires the Candidate to open the MG set motor supply breakers.
K/A 029EK3.12: Knowledge of the reasons for the following responses as they apply to the ATWS: Actions contained in EOP for ATWS (RO 4.4 SRO 4.7)
K/A 029EA1.12: Ability to operate and monitor the following as they apply to a ATWS: M/G set power supply and reactor trip breakers (RO 4.1 SRO 4.0)
NUREG 1122 EPE: 029, Anticipated Transient Without Scram (ATWS)
VCS Task: O-000-117-05-04 RESPOND TO ABNORMAL NUCLEAR POWER GENERATION
j. This is a bank JPM. This JPM was randomly selected and was last used in the 2016 NRC exam. The Candidate will be directed to de-energize and locally close and the MS Loop “B” and “C” supplies to the turbine driven Emergency Feedwater pump in accordance with EOP-3.0, E-2 FAULTED STEAM GENERATOR ISOLATION.
K/A: 040AA1.10: Ability to operate and/or monitor the following as they apply to the Steam Line Rupture: AFW system (RO: 4.1, SRO: 4.1)
NUREG 1122 APE: 040, Steam Line Rupture.
VCS Task: O-000-169-05-04, LOCALLY ISOLATE A FAULTED STEAM GENERATOR PER EOP-3.0.
k. This is a new JPM. The initial conditions for the JPM are 100% power with Spent Fuel Pool level at 461.1 ft., which is below the Tech Spec 3.7.10 limit in accordance with OAP-106.1, OPERATING ROUNDS. The candidate will be directed to raise Spent Fuel Pool level to 461.8 ft using SOP-123, SPENT FUEL COOLING SYSTEM. The Candidate will simulate lining up the Reactor Makeup Water flowpath to the Spent Fuel Pool and will raise level to the desired value.
K/A: 000033A1.01: Ability to predict and/or monitor changes in parameters (to prevent exceeding design limits) associated with Spent Fuel Pool Cooling System operating the controls including: Spent Fuel Pool Water Level (RO: 2.7, SRO: 3.3)
NUREG 1122 System: 033, Spent Fuel Pool Cooling System.
VCS Task: O-033-002-01-04, MAKEUP TO THE SPENT FUEL POOL PER SOP-123.
ES-301 Control Room/In-Plant Systems Outline Form Form ES-301-2
Facility: _____V.C.Summer Unit 1 Date of Examination: 6/4/2018
Exam Level: RO SRO-I SRO-U Operating Test No: NRC-ILO-16-01
Control Room Systems:* 8 for RO; 7 for SRO-I; 2 or 3 for SRO-U
System / JPM Title Type Code* Safety
Function
a. Not for SRO-U use. NA NA
b.
APE027: Pressurizer Pressure Control System (PZR PCS) Malfunction (JPS-002F-N18)
Stop RCPs per EOP-1.1, ES-0.1 to mitigate a stuck open PZR spray valve following a reactor trip.
M,A,L,S 3
c. Not for SRO-U use. NA NA
d. Not for SRO-U use. NA NA
e. Not for SRO-U use. NA NA
f. System 015: Nuclear Instrumentation System (JPS-006-N18)
Respond to power range Instrumentation channel N-44 fail low with rod control in automatic.
D,S 7
g. Not for SRO-U use. NA NA
h W/E 16: High Containment Radiation (JPS-008F-N18)
Align RB HEPA filters using EOP-17.2 following a high containment radiation condition post LOCA.
D,EN,A,L,P,S 9
In-Plant Systems* (3 for RO); (3 for SRO-I); (3 or 2 for SRO-U)
i System 001: Control Rod Drive System (JPP-0009F-N18)
Locally Trip the Reactor using EOP-13.0, FR-S.1. The trip breakers don’t open locally requiring MG set motor breakers to be opened locally.
D,A,E 1
j Not for SRO-U use. NA NA
k System 033: Spent Fuel Pool Cooling System (JPP-011-N18)
Fill Spent Fuel Pool using Rx M/U water in accordance with SOP-123. N,R 8
ES-301 Control Room/In-Plant Systems Outline Form Form ES-301-2
* All RO and SRO-I control room (and in-plant) systems must be different and serve different safety functions; all
five SRO-U systems must serve different safety functions; in-plant systems and functions may overlap those tested in the control room.
* Type Codes Criteria for RO / SRO-I / SRO-U SRO-U
(A)lternate path 4-6 / 4-6 / 2-3 3
(C)ontrol room
(D)irect from bank ≤ 9 / ≤ 8 / ≤ 4 3
(E)mergency or abnormal in-plant ≥ 1 / ≥ 1 / ≥ 1 1
(EN)gineered safety feature ≥ 1 / ≥ 1 / ≥ 1 (control room system) 1
(L)ow-Power / Shutdown ≥ 1 / ≥ 1 / ≥ 1 2
(N)ew or (M)odified from bank including 1(A) ≥ 2 / ≥ 2 / ≥ 1 2
(P)revious 2 exams ≤ 3 / ≤ 3 / ≤ 2 (randomly selected) 1
(R)CA ≥ 1 / ≥ 1 / ≥ 1 1
(S)imulator
VC SUMMER NRC RO JPM SUMMARY a. Not for SRO-U use.
b. This is a modified bank JPM. The JPM begins with the plant having tripped from 100% power. The Candidate will be told that the crew have transitioned to EOP-1.1, ES-0.1 Reactor Trip Response and have completed steps 1 through 7. The initiating cue to the Candidate will be to perform EOP-1.1 beginning at step 8, verify all Control Rods are fully inserted. Once the Candidate commences the performance of EOP-1.1 PZR spray valve PCV-444C will fail partially open causing PZR pressure to slowly lower. The Candidate will recognize PZR pressure is not stable or trending to 2230 psig at step 11 and will take alternative action beginning with a check of PZR PORVs closed and a check that PZR spray valves are closed. Attempts to close Spray valve PCV-444C will be unsuccessful and the Candidate will stop the “A” RCP and then will stop the “C” RCP. The JPM is considered alternate path due to the failure of the Pressurizer Spray valves to close when the operator attempts to close them which requires the stopping of RCPs.
K/A 027AA1.01: Ability to operate and/or monitor the following as they apply to the Pressurizer Pressure Control Malfunctions: PZR heaters, sprays, and PORVs. (RO 4.0 SRO 3.9)
NUREG 1122 APE: 027, Pressurizer Pressure Control System (PZR PCS) Malfunction.
VCS Task: O-000-509-05-02, RECOVER FROM REACTOR TRIP PER EOP-1.1
c. Not for SRO-U use. d. Not for SRO-U use. e. Not for SRO-U use.
ES-301 Control Room/In-Plant Systems Outline Form Form ES-301-2
f. This is a revision to a bank JPM. Initial conditions are 75% power all controls in automatic. The Candidate will be directed to respond to any developing plant conditions. Power Range NI channel N-44 will fail low causing auto rod withdrawal. The candidate will place rods in Manual and proceed to remove N-44 from service using AOP-401.10, POWER RANGE CHANNEL FAILURE.
K/A 000015A2.01: Ability to (a) predict the impacts of the following malfunctions or operations on the NIS; and (b) based on those predictions, use procedures to correct, control, or mitigate the consequences of those malfunctions or operations: Power supply loss or erratic operation. (RO 3.5, SRO 3.9)
NUREG 1122 System: 015, Nuclear Instrumentation System.
VCS Task: O-000-034-05-01, RESPOND TO POWER RANGE INSTUMENTATION CHANNEL FAILURE
g. Not for SRO-U use.
h. This is a bank JPM that has been revised. The initial conditions for this JPM are a yellow path condition on the Containment Critical safety function due to high radiation levels following a DBA LOCA. The CRS will direct the Candidate to implement EOP-17.2, RESPONSE TO HIGH REACTOR BUILDING RADIATION LEVEL. The Candidate will place all RBCU HEPA filter dampers in the filter position but XDP-110A, RBCU 64A HEPA and XDP-111B, RBCU 65B HEPA Filter Bypass Dampers will remain in the bypassed position. The 64A RBCU fan will be running thus the Candidate will be required to start the 65A RBCU. In addition the 64B RBCU failed to auto start and will require the operator to stop the 64B Normal fan and manually start the 64B slow fan to assure adequate HEPA filtration in service. The JPM is considered alternate path because the HEPA filters fail to properly align which requires the operator to take manual action to align filtration.
K/A W/E16EA1.1: Ability to operate and/or monitor the following as they apply to the (High Containment Radiation): Components, and functions of control and safety systems, including instrumentation, signals, interlocks, failure modes, and automatic and manual features. (RO 3.1 SRO 3.2)
NUREG 1122 W/E: E16, High Containment Radiation.
VCS Task: O-311-018-06-01, RESPONSE TO HIGH RB RADIATION.
i. This is a bank JPM. The initial conditions for this JPM are an ATWS. The CRS will direct the Candidate to implement EOP-13.0, FR-S.1 RESPONSE TO ABNORMAL NUCLEAR POWER GENERATION, Attachment 1-TRIPPING THE REACTOR LOCALLY. The Candidate will attempt to locally open the Reactor Trip and Bypass breakers but they will not open. Next the Candidate will attempt to open Rod Drive MG set motor and generator breakers and they also will not open. Finally the Candidate will open the 480 volt supply breakers to both Rod Drive MG set motors. The JPM is considered alternate path because the action to locally open Reactor Trip breakers fails which requires the Candidate to open the MG set motor supply breakers.
K/A 029EK3.12: Knowledge of the reasons for the following responses as they apply to the ATWS: Actions contained in EOP for ATWS (RO 4.4 SRO 4.7)
K/A 029EA1.12: Ability to operate and monitor the following as they apply to a ATWS: M/G set power supply and reactor trip breakers (RO 4.1 SRO 4.0)
NUREG 1122 EPE: 029, Anticipated Transient Without Scram (ATWS)
VCS Task: O-000-117-05-04 RESPOND TO ABNORMAL NUCLEAR POWER GENERATION
ES-301 Control Room/In-Plant Systems Outline Form Form ES-301-2
j. Not for SRO-U use.
k. This is a new JPM. The initial conditions for the JPM are 100% power with Spent Fuel Pool level at 461.1 ft., which is below the Tech Spec 3.7.10 limit in accordance with OAP-106.1, OPERATING ROUNDS. The candidate will be directed to raise Spent Fuel Pool level to 461.8 ft using SOP-123, SPENT FUEL COOLING SYSTEM. The Candidate will simulate lining up the Reactor Makeup Water flowpath to the Spent Fuel Pool and will raise level to the desired value.
K/A: 000033A1.01: Ability to predict and/or monitor changes in parameters (to prevent exceeding design limits) associated with Spent Fuel Pool Cooling System operating the controls including: Spent Fuel Pool Water Level (RO: 2.7, SRO: 3.3)
NUREG 1122 System: 033, Spent Fuel Pool Cooling System.
VCS Task: O-033-002-01-04, MAKEUP TO THE SPENT FUEL POOL PER SOP-123.
ES-401 Record of Rejected K/As Form ES-401-4
Tier / Group
Randomly Selected K/A
Reason for Rejection
RO KAs
Following change approved by phone conversation with Chief Examiner on 1/18/18.
2/1 026A1.04
026 A1.04 Containment Spray - Ability to predict and/or monitor changes
in parameters associated with operating the system controls including:
Containment Humidity
Utility comment: The KA wording does not provide the basis for a
discriminating question at the RO level. Actuation of Reactor Building
Spray will cause an increase in humidity. Reactor Building humidity is
not a parameter that is monitored in plant procedures or technical
specifications at V.C. Summer.
Replaced with 026 A1.03 , Containment Spray - Ability to predict and/or
monitor changes in parameters associated with operating the system
controls including: Containment Sump Level (RO 3.5 SRO 3.5)
Following change approved by phone conversation with Chief Examiner on 4/5/18.
1/2 037 AA2. 12 037 AA2. 12 Steam Generator Tube Leak / 3 - Ability to determine and
interpret the following as the apply to the event: Flow rate of leak
Utility comment: This KA overlaps with a simulator scenario
malfunction.
Replaced with 037 AA2.08 , Steam Generator Tube Leak / 3 - Ability to
determine and interpret the following as the apply to the event: Failure of
Condensate air ejector exhaust monitor. (RO 2.8 SRO 3.3)
Following change approved by phone conversation with Chief Examiner on 4/10/18.
2/2 041 K2.02 041 K2.02 Steam Dump/Turbine Bypass Control - Knowledge of the
electrical power supplies to the following: ICS inverter breakers.
Utility comment: ICS is a system that is not applicable to V.C. Summer.
Replaced with 041 K3.01 , Knowledge of the effect that a loss or
malfunction of the Steam Dump system will have on the following: S/G
(RO 3.2 SRO 3.3)
ES-401 Record of Rejected K/As Form ES-401-4
SRO KAs
Following change approved by phone conversation with Chief Examiner on 4/2/18.
1/2 076AA2.05 076AA2.05 High Reactor Coolant Activity - Ability to determine and
interpret the following as the apply to the event: CVCS letdown flow rate
indication
Utility comment: The KA wording does not provide the basis for a
discriminating question. The CVCS Letdown flow-rate in connection
with High RCS activity is an RO concept that cannot be satisfactorily
tested at the SRO level.
Replaced with 076AA2.02 High Reactor Coolant Activity - Ability to
determine and interpret the following as the apply to the event: Corrective
actions required for high fission product activity in RCS (RO 2.8 SRO
3.4)
Following change approved by phone conversation with Chief Examiner on 4/17/18.
2/1 004G2.4.47 004 G2.4.47 Chemical and Volume Control - Ability to diagnose and
recognize trends in an accurate and timely manner utilizing the appropriate
control room reference material.
Utility comment: The KA wording does not provide the basis for a
discriminating question.
Replaced with 004G2.4.8 Chemical and Volume Control - Knowledge of
how abnormal operating procedures are used in conjunction with EOPs.
(RO 3.8 SRO 4.5)
Following change approved by phone conversation with Chief Examiner on 4/25/18.
2/1 004G2.4.8 004 G2.4.8 Chemical and Volume Control - Knowledge of how abnormal
operating procedures are used in conjunction with EOPs. (RO 3.8 SRO
4.5)
Utility comment: The KA wording does not provide the basis for a
discriminating question at the SRO level.
Replaced with 062G2.4.8 AC Electrical Distribution - Knowledge of how
abnormal operating procedures are used in conjunction with EOPs. (RO
3.8 SRO 4.5)
ES-4
01
Writ
ten
Exam
inat
ion
Rev
iew
Wor
kshe
et
Form
ES-
401-
9
Q
# 1.
LO
K
(F/H
)
2.
LOD
(1
-5)
3. P
sych
omet
ric F
law
s 4.
Job
Con
tent
Fla
ws
5. O
ther
6.
B
/M/N
7.
U/E
/S
8.
Exp
lana
tion
Ste
m
Focu
s C
ues
T/F
Cre
d.
Dis
t. P
artia
l Jo
b-Li
nk
Min
utia
#/
un
its
Bac
k-w
ard
Q=
K/A
S
RO
O
nly
10 S
ampl
e Q
uest
ions
(5 R
O +
5 S
RO
) rec
eive
d on
12-
19-1
7 an
d fe
edba
ck p
rovi
ded
on 1
/11/
18.
The
Chi
ef E
xam
iner
PR
ELI
MIN
AR
ILY
dete
rmin
ed th
e fo
llow
ing
test
ite
ms
wer
e un
acce
ptab
le; h
owev
er, t
his
dete
rmin
atio
n is
not
fina
l un
til a
fter p
ost-e
xam
cha
nges
to th
e an
swer
key
, if a
ny, a
re
dete
rmin
ed:
RO
EXA
M (2
0/75
= 2
6%)
C
red
Dis
t: 6
, 7, 2
0, 2
2, 2
8, 3
3, 3
4, 4
3, 4
5, 4
6, 6
9, 7
0, &
72
Q
=K/A
: 2,
12,
18,
37,
52,
53,
62
SRO
EXA
M (9
/25
= 36
%)
Q
=K/A
: 76
, 81,
& 8
5
S
RO
-onl
y: 7
7, 8
1, 8
6, 8
9
C
red
Dis
t: 8
8, 9
5, &
96
Als
o, th
e C
hief
Exa
min
er P
RE
LIM
INA
RIL
Y de
term
ined
som
e qu
estio
ns w
ere
bord
erlin
e, a
nd th
ese
item
s ar
e id
entif
ied
as “E
/U”.
Th
ese
E/U
item
s w
ere
NO
T de
term
ined
to b
e un
acce
ptab
le e
ven
thou
gh th
e qu
estio
n fla
w(s
) was
/wer
e te
chni
cally
con
side
red
unac
cept
able
. Th
e re
ason
thes
e te
st it
ems
wer
e no
t det
erm
ined
to
be u
nacc
epta
ble
was
due
to v
ario
us fa
ctor
s su
ch a
s di
fficu
lt K
/As
(whe
re re
plac
emen
t is
likel
y), m
inor
adj
ustm
ents
to th
e S
tem
or
Cho
ices
reso
lved
pla
usib
ility
con
cern
s, o
r a K
/A te
chni
cal n
uanc
e w
as m
isse
d. T
he re
solu
tion
of th
ese
initi
al E
/U d
eter
min
atio
ns w
ill
occu
r afte
r pos
t-exa
m c
hang
es to
the
answ
er k
ey, i
f any
, are
de
term
ined
.
All
EN
HA
NC
EM
EN
T C
omm
ents
sho
uld
be c
orre
cted
bef
ore
the
exam
is a
dmin
iste
red.
The
term
“Los
s of
Coo
lant
Acc
iden
t” is
use
d in
som
e te
st it
ems
even
th
ough
it is
n’t u
sed
in o
ther
test
item
s lik
e Q
#3 a
nd Q
#4, w
here
the
acro
nym
LO
CA
is u
sed.
Nee
d to
be
cons
iste
nt th
ough
out
the
entir
e ex
am.
The
wor
d “b
elow
” in
each
ste
m q
uest
ion
is n
ot n
eces
sary
.
Q
# 1.
LO
K
(F/H
)
2.
LOD
(1
-5)
3. P
sych
omet
ric F
law
s 4.
Job
Con
tent
Fla
ws
5. O
ther
6.
B
/M/N
7.
U/E
/S
8.
Exp
lana
tion
Ste
m
Focu
s C
ues
T/F
Cre
d.
Dis
t. P
artia
l Jo
b-Li
nk
Min
utia
#/
un
its
Bac
k-w
ard
Q=
K/A
S
RO
O
nly
Giv
en a
gen
eric
fill-
in-th
e-bl
ank
stat
emen
t, su
ch a
s:
“The
CR
S w
ill d
irect
___
(1)_
__ a
s a
resu
lt of
thes
e co
nditi
ons.
”
The
stem
que
stio
ns a
nd C
hoic
es s
houl
d be
wor
ded
in te
rms
of
wha
t is
requ
ired
(or n
ot re
quire
d) to
be
impl
emen
ted,
bec
ause
as
king
wha
t CR
S is
goi
ng to
dire
ct c
an b
e su
bjec
tive.
Kee
ping
a
focu
s on
wha
t is/
is n
ot re
quire
d of
ten
help
s w
ith te
st it
em
cons
truct
ion.
The
“CR
S” p
iece
of t
he s
tate
men
t is
not r
equi
red
for S
RO
-onl
y te
st it
ems.
Ins
tead
, for
exa
mpl
e, “C
RS
” can
alw
ays
be
elim
inat
ed:
“___
(1)_
___
is re
quire
d.”
(pro
cedu
re A
vs
proc
edur
e B
)
Giv
en a
gen
eric
fill-
in-th
e-bl
ank
stat
emen
t, su
ch a
s:
“Prio
r to
adju
stin
g X
, the
AB
C p
ushb
utto
n __
_(2)
___
be d
epre
ssed
.”
Inst
ead
of h
avin
g th
e C
hoic
es a
s “w
ill o
r will
not
”, it
is b
ette
r fro
m th
e P
artia
l fla
w p
ersp
ectiv
e to
hav
e th
e C
hoic
es w
orde
d as
“is/
is N
OT
requ
ired.
”
R
efer
to S
ectio
n D
of E
S-4
01 a
nd A
ppen
dix
B fo
r add
ition
al in
form
atio
n re
gard
ing
each
of t
he fo
llow
ing
conc
epts
:
1.
Ent
er th
e le
vel o
f kno
wle
dge
(LO
K) o
f eac
h qu
estio
n as
eith
er (F
)und
amen
tal o
r (H
)ighe
r cog
nitiv
e le
vel.
2.
Ent
er th
e le
vel o
f diff
icul
ty (L
OD
) of e
ach
ques
tion
a 1(
easy
) to
5 (d
iffic
ult);
que
stio
ns w
ith a
diff
icul
ty b
etw
een
2 an
d 4
are
acce
ptab
le.
3.
Che
ck th
e ap
prop
riate
box
if a
psy
chom
etric
flaw
is id
entif
ied:
•
“Ste
m F
ocus
”: T
he s
tem
lack
s su
ffici
ent f
ocus
to e
licit
the
corre
ct a
nsw
er (e
.g.,
uncl
ear i
nten
t, m
ore
info
rmat
ion
is n
eede
d, o
r too
muc
h ne
edle
ss in
form
atio
n).
• “C
ues”
: Th
e st
em o
r dis
tract
ors
cont
ain
cues
(i.e
., cl
ues,
spe
cific
det
erm
iner
s, p
hras
ing,
leng
th, e
tc.).
•
“T/F
”: T
he a
nsw
er c
hoic
es a
re a
col
lect
ion
of u
nrel
ated
true
/fals
e st
atem
ents
. •
“Cre
d. D
ist”:
The
dis
tract
ors
are
not c
redi
ble;
sin
gle
impl
ausi
ble
dist
ract
ors
shou
ld b
e re
paire
d, m
ore
than
one
is u
nacc
epta
ble.
•
“Par
tial”:
One
or m
ore
dist
ract
ors
are
parti
ally
cor
rect
(e.g
., if
the
appl
ican
t can
mak
e un
stat
ed a
ssum
ptio
ns th
at a
re n
ot c
ontra
dict
ed b
y st
em).
4.
Che
ck th
e ap
prop
riate
box
if a
job
cont
ent f
law
is id
entif
ied:
•
“Job
Lin
k”:
The
ques
tion
is n
ot li
nked
to th
e jo
b re
quire
men
ts (i
.e.,
the
ques
tion
has
a va
lid K
/A b
ut, a
s w
ritte
n, is
not
ope
ratio
nal i
n co
nten
t).
• “M
inut
ia”:
The
que
stio
n re
quire
s th
e re
call
of k
now
ledg
e th
at is
too
spec
ific
for t
he c
lose
d re
fere
nce
test
mod
e (i.
e., i
t is
not r
equi
red
to b
e kn
own
from
mem
ory)
. •
“# /
Uni
ts”:
The
que
stio
n co
ntai
ns d
ata
with
an
unre
alis
tic le
vel o
f acc
urac
y or
inco
nsis
tent
uni
ts (e
.g.,
pane
l met
er in
per
cent
with
que
stio
n in
gal
lons
). •
“Bac
kwar
d”:
The
ques
tion
requ
ires
reve
rse
logi
c or
app
licat
ion
com
pare
d to
the
job
requ
irem
ents
. 5.
C
heck
que
stio
ns fo
r con
form
ance
with
the
appr
oved
K/A
and
thos
e K
/As
that
are
des
igna
ted
“SR
O-o
nly.
” (K
/A a
nd li
cens
e le
vel m
ism
atch
es a
re u
nacc
epta
ble)
6.
E
nter
que
stio
n’s
sour
ce: (
B)a
nk, (
M)o
difie
d, o
r (N
)ew
. V
erify
that
(M)o
difie
d qu
estio
ns m
eet t
he c
riter
ia o
f ES
-401
Sec
tion
D.2
.f.
7.
Bas
ed o
n th
e re
view
er's
judg
men
t, is
the
ques
tion
as w
ritte
n (U
)nsa
tisfa
ctor
y (r
equi
ring
repa
ir or
repl
acem
ent),
in n
eed
of (E
)dito
rial e
nhan
cem
ent,
or (S
)atis
fact
ory?
8.
A
t a m
inim
um, e
xpla
in a
ny "U
" Sta
tus
ratin
gs (e
.g.,
how
the
App
endi
x B
psy
chom
etric
attr
ibut
es a
re n
ot b
eing
met
).
ES-4
01
2 Fo
rm E
S-40
1-9
Q#
1.
LOK
(F
/H)
2.
LOD
(1
-5)
3. P
sych
omet
ric F
law
s 4.
Job
Con
tent
Fla
ws
5. O
ther
6.
S
ourc
e B
/M/N
7.
Sta
tus
U/E
/S
8.
Exp
lana
tion
Ste
m
Focu
s C
ues
T/F
Cre
d.
Dis
t. P
artia
l Jo
b-Li
nk
Min
utia
#/
un
its
Bac
k-w
ard
Q=
K/A
S
RO
O
nly
1 H
2
x
x x
x
M
E
T1
G1
007
(Rea
ctor
Trip
-Sta
biliz
atio
n) K
2.03
1.
Cue
: Th
e ca
pita
lized
wor
ding
in C
hoic
e C
(PZR
PR
ES
S L
O) i
s no
t nec
essa
ry to
elic
it th
e co
rrec
t res
pons
e. S
ugge
st re
-wor
ding
C
hoic
e C
as:
“The
firs
t rea
ctor
trip
sig
nal w
as lo
w p
ress
uriz
er p
ress
ure.
”
2.
Cue
: Th
e on
ly a
nsw
er c
hoic
e th
at m
entio
ns a
reac
tor t
rip is
als
o th
e co
rrec
t ans
wer
; sug
gest
re-w
ordi
ng C
hoic
e B
as:
“The
firs
t rea
ctor
trip
sig
nal w
as lo
w s
team
gen
erat
or le
vel.”
3.
Par
tial:
Is th
e on
ly re
ason
why
Cho
ice
D (p
ress
uriz
er p
ress
ure
rose
bac
k ab
ove
set p
oint
) is
inco
rrec
t bec
ause
the
stem
qu
estio
n di
rect
s ap
plic
ants
to O
NLY
use
the
annu
ncia
tor
info
rmat
ion
liste
d ab
ove?
If s
o, th
en a
n ap
plic
ant c
an s
till
succ
essf
ully
app
eal t
hat C
hoic
e D
is a
lso
corr
ect b
ecau
se
pres
suriz
er p
ress
ure
coul
d in
deed
be
back
abo
ve it
s se
t poi
nt.
4.
Par
tial:
In th
e di
stra
cter
ana
lysi
s, in
clud
e th
e re
ason
why
C
hoic
e A
(tur
bine
was
man
ually
trip
ped)
is in
corr
ect.
(Is
the
reas
on b
ecau
se a
Tur
bine
trip
from
100
% p
ower
= lo
ss o
f loa
d,
whi
ch w
ill n
ot e
ver a
lso
caus
e lo
w p
ress
uriz
er p
ress
ure?
)
5.
Job-
Link
: Th
e op
erat
iona
l val
idity
of u
sing
the
Firs
t Out
Pan
el to
id
entif
y w
hat c
ause
d a
trip
may
be
that
the
crew
is a
t Ste
p 20
of
EO
P-1
.1 (s
ee b
elow
); m
odify
ing
the
2nd s
tem
bul
let t
o al
so
men
tion
that
the
crew
is p
erfo
rmin
g S
tep
20 o
f EO
P-1
.1 m
ay b
e w
orth
whi
le.
You
may
con
side
r pas
ting
Ste
p 20
in th
e st
em, t
o en
sure
the
oper
atio
nal v
alid
ity o
f the
test
item
. 6.
#/
units
: Th
e tit
le o
f EO
P-1
.1 is
inco
rrec
t; th
e tit
le in
the
stem
sh
ould
be
“Rea
ctor
Trip
Res
pons
e.”
Als
o, th
e X
CP
-626
te
rmin
olog
y sh
ould
be
cons
iste
nt w
ith th
e te
rmin
olog
y us
ed in
Q
#63.
7.
4-19
-18:
Com
men
ts in
corp
orat
ed; Q
uest
ion
is S
AT.
Q
# 1.
LO
K
(F/H
)
2.
LOD
(1
-5)
3. P
sych
omet
ric F
law
s 4.
Job
Con
tent
Fla
ws
5. O
ther
6.
S
ourc
e B
/M/N
7.
Sta
tus
U/E
/S
8.
Exp
lana
tion
Ste
m
Focu
s C
ues
T/F
Cre
d.
Dis
t. P
artia
l Jo
b-Li
nk
Min
utia
#/
un
its
Bac
k-w
ard
Q=
K/A
S
RO
O
nly
2 H
2
x x
x
B
U
T1
G1
008
(PZR
Vap
or S
pace
Acc
iden
t) A
K2.
03
1.
Q=K
/A:
The
prem
ise
of th
e te
st it
em is
a tr
ansi
ent t
hat i
s au
tom
atic
ally
term
inat
ed (n
o op
erat
or a
ctio
n) b
y th
e au
to-
clos
ure
of th
e P
OR
V a
t P-1
1. T
he K
/A re
quire
s te
stin
g a
pres
suriz
er v
apor
spa
ce A
CC
IDE
NT,
whi
ch is
a s
tuck
ope
n P
OR
V. (
See
008
title
on
page
4.2
-8 o
f PW
R C
atal
og)
2.
Cue
: Q
# 35
tells
the
appl
ican
ts th
at th
e M
aste
r Pre
ssur
e C
ontro
ller i
s re
late
d to
PC
V-4
44B
.
3.
Ste
m F
ocus
: In
the
stem
que
stio
n ite
m 1
, the
wor
d “fa
ilure
(s)”
sh
ould
not
incl
ude
pare
nthe
sis
beca
use
the
test
item
is a
skin
g th
e ap
plic
ant t
o de
term
ine
whi
ch P
OR
V(s
) will
ope
n gi
ven
BO
TH
of th
e fa
ilure
s. S
ugge
st re
-wor
ding
as:
“Whi
ch P
ress
uriz
er P
WR
RE
LIE
F P
OR
V(s
) will
aut
o-op
en d
ue
to th
ese
two
failu
res?
”
4.
Ste
m F
ocus
: Th
e st
em q
uest
ion
refe
rs to
ste
m it
ems
1 an
d 2
as
“sta
tem
ents
”, ev
en th
ough
item
s 1
and
2 ar
e “q
uest
ions
.”
Con
side
r usi
ng fi
ll-in
-the-
blan
k st
atem
ents
. O
ther
wis
e, re
-wor
d th
e st
em q
uest
ion
to a
sk “W
OO
TF c
hoic
es b
elow
com
plet
es
both
que
stio
ns?”
5.
Ste
m F
ocus
: Th
e w
ords
“PW
R R
ELI
EF”
in e
ach
choi
ce a
re
redu
ndan
t.
6.
4-19
-18:
Rew
rote
que
stio
n to
als
o in
clud
e P
-11
failu
re to
allo
w
pres
sure
to c
ontin
ue to
low
er; c
omm
ents
inco
rpor
ated
, Que
stio
n is
SA
T.
Q
# 1.
LO
K
(F/H
)
2.
LOD
(1
-5)
3. P
sych
omet
ric F
law
s 4.
Job
Con
tent
Fla
ws
5. O
ther
6.
S
ourc
e B
/M/N
7.
Sta
tus
U/E
/S
8.
Exp
lana
tion
Ste
m
Focu
s C
ues
T/F
Cre
d.
Dis
t. P
artia
l Jo
b-Li
nk
Min
utia
#/
un
its
Bac
k-w
ard
Q=
K/A
S
RO
O
nly
3 H
2
x
N
E
T1
G1
009
(SB
LOC
A) E
A2.
39
1.
Ste
m F
ocus
: Th
e Ti
me
1200
bul
let s
eque
nce
is n
ot a
ccur
ate
if th
e cr
ew e
nter
ed E
OP
-2.1
(Pos
t LO
CA
Coo
ldow
n &
D
epre
ssur
izat
ion)
from
EO
P-1
.1 (S
afet
y In
ject
ion
Term
inat
ion)
, be
caus
e th
e “B
” Cha
rgin
g P
ump
is s
topp
ed in
side
of E
OP
-1.2
(a
t Ste
p 1)
, but
the
RH
R P
umps
wer
e st
oppe
d in
EO
P-2
.1 (a
t S
tep
3).
If th
e cr
ew’s
pro
gres
sion
was
E1
EO
P-1
.2
EO
P-2
.1, t
hen
sugg
est r
e-or
gani
zing
the
stem
as:
A S
mal
l Bre
ak L
OC
A o
ccur
red
and
the
follo
win
g ac
tions
wer
e ta
ken
and/
or c
ondi
tions
exi
sted
:
Tim
e 12
00:
“B
” Cha
rgin
g P
ump
was
sto
pped
Tim
e 12
05:
E
OP
-2.1
, ES
-1.2
Pos
t-LO
CA
Coo
ldow
n an
d D
epre
ssur
izat
ion
is in
pro
gres
s
“A
” and
“B” R
HR
Pum
ps w
ere
stop
ped
Tim
e 12
10:
E
tc.
2.
Ste
m F
ocus
: C
hoic
e A
can
be
stre
amlin
ed a
s: “
adeq
uate
.”
3.
Ste
m F
ocus
: In
Cho
ices
B, C
, and
D, r
epla
ce th
e w
ord
“sho
uld”
w
ith “i
s re
quire
d.”
4.
Ste
m F
ocus
: Fo
r the
Tim
e 12
05 it
ems,
repl
ace
the
wor
d “r
eads
” w
ith a
col
on.
5.
4-19
-18:
Bul
lets
wer
e in
seq
uenc
e be
caus
e cr
ew n
ever
wen
t to
ES
-1.1
(SI T
erm
inat
ion)
; wen
t stra
ight
from
EO
P-2
(E1)
to E
OP
-2.
1 (E
S-1
.2).
Oth
er c
omm
ents
inco
rpor
ated
with
min
or
enha
ncem
ents
; Que
stio
n is
SA
T.
Q
# 1.
LO
K
(F/H
)
2.
LOD
(1
-5)
3. P
sych
omet
ric F
law
s 4.
Job
Con
tent
Fla
ws
5. O
ther
6.
S
ourc
e B
/M/N
7.
Sta
tus
U/E
/S
8.
Exp
lana
tion
Ste
m
Focu
s C
ues
T/F
Cre
d.
Dis
t. P
artia
l Jo
b-Li
nk
Min
utia
#/
un
its
Bac
k-w
ard
Q=
K/A
S
RO
O
nly
4 F
2 x
x x
N
E
T1G
1 0
11 (L
BLO
CA
) E
K3.
08
1.
Par
tial:
The
4th b
ulle
t, th
e st
em q
uest
ion,
and
the
wor
ding
of t
he
fill-i
n-th
e-bl
ank
stat
emen
t nee
d to
be
wor
ded
to e
nsur
e on
ly o
ne
corr
ect c
hoic
e, b
y ad
ding
mor
e fo
cus
to th
e ch
argi
ng p
ump
min
i-flo
w v
alve
s as
dis
cuss
ed in
the
ERG
Bas
es. S
peci
fical
ly,
Th
e 4th
bul
let i
s to
o ge
nera
l (“O
pera
tors
are
taki
ng th
e m
anua
l act
ions
requ
ired
to c
ompl
ete
the
long
-term
re
circ
ulat
ion
lineu
p of
EC
CS
sys
tem
s.”)
and
cou
ld a
pply
to
any
valv
e al
ignm
ent.
Sug
gest
revi
sing
the
4th b
ulle
t to
say:
“The
cre
w is
per
form
ing
Ste
p 8
to a
lign
char
ging
pum
ps fo
r co
ld-le
g re
circ
ulat
ion.
”
Th
e st
em q
uest
ion
shou
ld b
e w
orde
d as
:
“WO
OTF
com
plet
es th
e fo
llow
ing
stat
emen
t in
acco
rdan
ce
with
the
emer
genc
y re
spon
se g
uide
lines
’ bas
es
docu
men
t?”
Th
e fil
l-in-
the-
blan
k st
atem
ent s
houl
d be
wor
ded,
in a
plu
ral
sens
e, a
s:
“The
reas
on w
hy th
ese
valv
es a
re c
lose
d, is
to _
____
.”
2.
Cre
d D
ist:
The
pla
usib
ility
of C
hoic
e C
(hot
leg
reci
rc) s
houl
d be
en
hanc
ed b
ecau
se th
e 3rd
bul
let i
n th
e st
em s
ays
the
crew
is
trans
ferr
ing
to c
old
leg
reci
rc.
Sug
gest
re-w
ordi
ng C
hoic
e C
as:
“C.
pre
-alig
n va
lves
for t
rans
ferr
ing
to h
ot le
g re
circ
late
r.”
3.
Ste
m F
ocus
: C
hoic
e A
can
be
clar
ified
as:
“A.
pre
vent
bac
kflo
w th
roug
h th
e id
le R
HR
loop
.”
4.
4-17
-18:
All
com
men
ts in
corp
orat
ed; q
uest
ion
is S
AT.
Q
# 1.
LO
K
(F/H
)
2.
LOD
(1
-5)
3. P
sych
omet
ric F
law
s 4.
Job
Con
tent
Fla
ws
5. O
ther
6.
S
ourc
e B
/M/N
7.
Sta
tus
U/E
/S
8.
Exp
lana
tion
Ste
m
Focu
s C
ues
T/F
Cre
d.
Dis
t. P
artia
l Jo
b-Li
nk
Min
utia
#/
un
its
Bac
k-w
ard
Q=
K/A
S
RO
O
nly
5 H
2
x x
x
N
E
T1
G1
015
(RC
P M
alfu
nctio
ns)
AG
2.1.
31
1.
Par
tial:
The
ste
m q
uest
ion
need
s to
be
wor
ded
to e
nsur
e on
ly
one
corr
ect a
nsw
er; t
he w
ord
“cou
ld” i
n th
e st
em q
uest
ion
and
not d
irect
ly a
skin
g w
hat t
he a
nnun
ciat
or p
roce
dure
say
s ca
n yi
eld
Cho
ice
C a
s al
so c
orre
ct, b
ecau
se c
losi
ng F
CV
-122
wou
ld
tend
to d
rive
up s
eal i
njec
tion
pres
sure
. S
ugge
st re
visi
ng th
e st
em q
uest
ion
as:
“WO
OTF
iden
tifie
s a
prob
able
cau
se o
f thi
s al
arm
in a
ccor
danc
e w
ith th
e an
nunc
iato
r pro
cedu
re?”
2.
Cue
: Th
e w
ord
“abn
orm
al” i
n th
e st
em q
uest
ion
is n
ot n
eede
d to
elic
it th
e co
rrec
t res
pons
e.
3.
Ste
m F
ocus
: Th
e 2nd
bul
let c
an b
e sh
orte
ned
to s
ay:
“The
follo
win
g al
arm
is re
ceiv
ed:”
4.
Ste
m F
ocus
: Th
e w
ord
“ala
rm” a
t the
end
of t
he a
nnun
ciat
or’s
na
me
is n
ot n
eces
sary
.
5.
4-17
-18:
All
com
men
ts in
corp
orat
ed; q
uest
ion
is S
AT.
6 H
2
x
x
N
U
T1
G1
022
(Los
s of
RC
S M
akeu
p) A
K1.
03
1.
Cre
d D
ist:
The
2nd
par
t of C
hoic
es A
/C (b
acku
p he
ater
s ca
n be
en
ergi
zed
whe
n a
HE
ATE
R B
LOC
K a
larm
exi
sts)
is n
ot
plau
sibl
e be
caus
e th
e na
me
of th
e X
CP
-616
ala
rm is
“blo
cked
he
ater
s.”
2.
Ste
m F
ocus
: Th
e fil
l-in-
the-
blan
k st
atem
ent c
an b
e sh
orte
ned,
tig
hten
ed to
pre
clud
e pa
rtial
ly c
orre
ct C
hoic
es, a
nd c
larif
ied
by
revi
sing
as:
“The
set
poi
nt fo
r XC
P-6
16, 1
-3 is
_(1
)__;
at t
his
time,
the
Gro
up
2 B
acku
p H
eate
rs _
__(2
)___
_ be
man
ually
ene
rgiz
ed.”
3.
Ste
m F
ocus
: Th
e 3rd
bul
let s
houl
d te
ll th
e ap
plic
ant w
hat
posi
tion
the
BU
GR
P 1
sw
itch
is in
. (In
stea
d of
telli
ng th
em th
e he
ater
s ar
e en
ergi
zed)
.
4.
Ste
m F
ocus
: Th
e w
ords
“and
sta
ble”
in th
e 1st
bul
let a
re n
ot
nece
ssar
y. A
lso,
the
wor
d “b
elow
” in
the
stem
que
stio
n is
not
ne
cess
ary.
5.
4-19
-18:
Rew
rote
que
stio
n; n
ew q
uest
ion
is S
AT.
Q
# 1.
LO
K
(F/H
)
2.
LOD
(1
-5)
3. P
sych
omet
ric F
law
s 4.
Job
Con
tent
Fla
ws
5. O
ther
6.
S
ourc
e B
/M/N
7.
Sta
tus
U/E
/S
8.
Exp
lana
tion
Ste
m
Focu
s C
ues
T/F
Cre
d.
Dis
t. P
artia
l Jo
b-Li
nk
Min
utia
#/
un
its
Bac
k-w
ard
Q=
K/A
S
RO
O
nly
7 H
2
x
x
x
N
U
T1
G1
025
(Los
s of
RH
R)
AA
1.01
1.
Cre
d D
ist:
The
1st p
art o
f Cho
ices
C/D
(clo
sing
Hx
outle
t val
ve
rais
es c
oold
own
rate
) is
not p
laus
ible
bec
ause
HC
V-6
03A
is th
e he
at e
xcha
nger
out
let v
alve
. S
ugge
st re
-wor
king
the
first
par
t of
the
ques
tion
to te
st th
e ap
plic
ants
’ kno
wle
dge
of h
ow A
OP
-11
5.3
dire
cts
the
oper
ator
rais
e th
e co
oldo
wn
rate
.
2.
Bac
kwar
d: T
he q
uest
ion
is d
isjo
inte
d be
caus
e th
e 6th
bul
let i
n th
e st
em s
ays
that
the
crew
exi
ted
AO
P-1
15.3
, eve
n th
ough
ite
m #
1 in
the
stem
que
stio
n as
ks a
bout
the
allo
wan
ces
to
incr
ease
coo
ldow
n in
acc
orda
nce
with
AO
P-1
15.3
, and
the
curr
ent c
ondi
tions
bul
lets
indi
cate
AO
P-1
15.3
, Ste
p 7.
k is
in
prog
ress
. S
ugge
st d
elet
ing
the
6th b
ulle
t in
the
stem
.
The
6th b
ulle
t was
pro
babl
y in
clud
ed to
add
pla
usib
ility
to th
e 50
ºF/h
r dis
tract
er, s
ince
GO
P-0
6 re
fers
to a
50
degr
ee c
hang
e in
any
hou
r whe
n R
CS
tem
pera
ture
is ≤
200
ºF.
How
ever
, un
less
the
6th b
ulle
t is
dele
ted,
the
K/A
mat
ch m
ay b
e in
je
opar
dy s
ince
the
inte
nt w
as to
test
the
abno
rmal
Los
s of
RH
R
evol
utio
n, n
ot th
e G
OP
-06
norm
al c
oold
own
evol
utio
n. T
o en
sure
pla
usib
ility
of t
he 5
0ºF/
hr d
istra
cter
, elim
inat
e th
e ca
pita
lized
wor
ds in
the
stem
item
#2
(T.S
. 3.4
.9.1
P
RE
SS
UR
E/T
EM
PE
RA
TUR
E L
IMIT
S-R
EA
CTO
R C
OO
LAN
T S
YSTE
M).
Q
# 1.
LO
K
(F/H
)
2.
LOD
(1
-5)
3. P
sych
omet
ric F
law
s 4.
Job
Con
tent
Fla
ws
5. O
ther
6.
S
ourc
e B
/M/N
7.
Sta
tus
U/E
/S
8.
Exp
lana
tion
Ste
m
Focu
s C
ues
T/F
Cre
d.
Dis
t. P
artia
l Jo
b-Li
nk
Min
utia
#/
un
its
Bac
k-w
ard
Q=
K/A
S
RO
O
nly
8 H
2
x
x
x
x
N
E
S
AM
PLE
QU
ES
TIO
N R
EC
EIV
ED
12-
19-1
7
T1G
1 0
27 (P
ZR P
CS
Mal
func
tion)
AA
2.07
1.
Par
tial:
Dur
ing
the
post
-exa
m a
ppea
l pro
cess
an
appl
ican
t can
su
cces
sful
ly a
rgue
that
ther
e is
no
corr
ect a
nsw
er s
ince
:
1) th
e st
em o
f the
que
stio
n is
mis
sing
pre
ssur
izer
hea
ters
’ (an
d ba
ckup
hea
ter)
sta
tus
and
2) th
e op
erat
iona
l val
idity
of p
ress
uriz
er p
ress
ure
bein
g ex
actly
st
able
with
an
ongo
ing
11 g
pm R
CS
vap
or s
pace
ste
am le
ak is
qu
estio
nabl
e.
If w
e se
tup
the
sim
ulat
or w
ith a
leak
ing
PO
RV
, the
re w
ill b
e ot
her i
ndic
atio
ns, w
hich
are
not
pro
vide
d in
the
stem
, and
pr
essu
rizer
pre
ssur
e w
ill in
itial
ly tr
y to
low
er, w
hich
will
cau
se a
ll he
ater
s an
d ba
ckup
hea
ters
to tu
rn o
n, P
RT
tem
pera
ture
will
ris
e, e
tc.
2.
Cre
d D
ist:
Cho
ice
C (L
etdo
wn
Pre
ssur
e C
ontro
l Val
ve
mal
func
tion
exis
ts) i
s no
t pla
usib
le b
ecau
se th
e st
em o
f the
qu
estio
n do
es n
ot in
clud
e th
e le
tdow
n pr
essu
re in
dica
tion
on
PT-
145.
3.
#/un
its:
For e
very
que
stio
n on
the
exam
, ens
ure
the
exac
t nou
n na
me
on th
e m
eter
/reco
rder
/han
dsw
itch
is u
sed
in th
e st
em.
Is
LI-4
59A
nam
ed “L
evel
%?”
Is P
I-457
nam
ed “P
RE
SS
PS
IG?”
It
seem
s lik
e th
ese
two
met
ers
are
mis
sing
the
wor
d “p
ress
uriz
er”
in th
e tit
le o
f the
met
er.
4.
Ste
m F
ocus
: Th
e ph
rase
“Con
ditio
ns c
an b
e ca
used
by”
in
Cho
ices
B, C
, and
D is
not
nec
essa
ry.
8 H
2
x
N
E
T1
G1
027
(PZR
PC
S M
alfu
nctio
n) A
A2.
07
Not
e: T
he o
rigin
al s
ampl
e qu
estio
n (a
bove
) was
com
plet
ely
repl
aced
w
ith a
new
test
item
.
1.
Ste
m F
ocus
: Th
e w
ord
“val
ves”
in th
e 2nd
bul
let s
houl
d be
“v
alve
.”
2.
Ste
m F
ocus
: Th
e ph
rase
“in
a ra
nge
of” i
n th
e 1st
fill-
in-th
e-bl
ank
stat
emen
t is
not n
eede
d.
3.
Ste
m F
ocus
: Th
e ph
rase
“whi
ch o
f the
Pre
ssur
izer
PO
RV
s is
le
akin
g” in
the
2nd fi
ll-in
-the-
blan
k st
atem
ent s
houl
d be
“whi
ch
Pre
ssur
izer
PO
RV
is le
akin
g.”
4.
4-17
-18:
Com
men
ts in
corp
orat
ed; q
uest
ion
is S
AT.
Q
# 1.
LO
K
(F/H
)
2.
LOD
(1
-5)
3. P
sych
omet
ric F
law
s 4.
Job
Con
tent
Fla
ws
5. O
ther
6.
S
ourc
e B
/M/N
7.
Sta
tus
U/E
/S
8.
Exp
lana
tion
Ste
m
Focu
s C
ues
T/F
Cre
d.
Dis
t. P
artia
l Jo
b-Li
nk
Min
utia
#/
un
its
Bac
k-w
ard
Q=
K/A
S
RO
O
nly
9 H
2
x
N
E
T1
G1
038
(Ste
am G
ener
ator
Tub
e R
uptu
re) E
A2.
15
1.
Par
tial:
The
ste
m q
uest
ion
shou
ld a
lign
mor
e cl
osel
y w
ith S
tep
9 of
EO
P-4
.1C
. S
ugge
st re
-writ
ing
the
stem
que
stio
n as
:
“Giv
en th
ese
cond
ition
s, W
OO
TF c
hoic
es id
entif
ies
the
requ
ired
actio
n to
min
imiz
e pr
imar
y to
sec
onda
ry le
akag
e, in
acc
orda
nce
with
EO
P-4
.1C
, Ste
p 9?
”
2.
4-17
-18:
Com
men
t inc
orpo
rate
d; q
uest
ion
is S
AT.
10
F 2
x
N
E
S
AM
PLE
QU
ES
TIO
N R
EC
EIV
ED
12-
19-1
7
T1G
1 0
55 (S
BO
) EA
1.02
1.
Ste
m F
ocus
: Th
e w
ordi
ng o
f the
1st fi
ll-in
-the-
blan
k is
cry
ptic
(“
oper
ate
a ph
ysic
al c
ontro
l”); t
he 1
st p
art o
f the
que
stio
n is
real
ly
aski
ng ju
st w
heth
er a
loca
l sta
rt is
or i
s no
t req
uire
d. S
ugge
st
stre
amlin
ing
both
sta
tem
ents
:
Whi
ch O
NE
of t
he fo
llow
ing
com
plet
es b
oth
stat
emen
ts in
ac
cord
ance
with
EO
P-6
.0?
The
oper
ator
___
____
requ
ired
to d
irect
a lo
cal s
tart
atte
mpt
for
a E
DG
bef
ore
load
s on
bus
ses
1DA
and
1D
B a
re ta
ken
to
PU
LL T
O L
K N
ON
-A.
(is
vs is
NO
T)
The
max
imum
KW
load
ing
for c
ontin
uous
ope
ratio
n is
___
_.
2.
Ste
m F
ocus
: Th
e 2nd
and
3rd
bul
lets
are
not
nec
essa
ry.
3.
Ste
m F
ocus
: Th
e fir
st p
art o
f bul
let 5
(“Th
e C
RS
ann
ounc
ed
entry
”) c
an b
e cl
arifi
ed a
s “T
he c
rew
ent
ered
.”
4.
Ste
m F
ocus
: Th
e un
derli
ne p
ortio
n of
the
1st fi
ll-in
-the-
blan
k st
atem
ent c
ould
be
limite
d to
the
wor
d “c
ontin
uous
.”
Q
# 1.
LO
K
(F/H
)
2.
LOD
(1
-5)
3. P
sych
omet
ric F
law
s 4.
Job
Con
tent
Fla
ws
5. O
ther
6.
S
ourc
e B
/M/N
7.
Sta
tus
U/E
/S
8.
Exp
lana
tion
Ste
m
Focu
s C
ues
T/F
Cre
d.
Dis
t. P
artia
l Jo
b-Li
nk
Min
utia
#/
un
its
Bac
k-w
ard
Q=
K/A
S
RO
O
nly
10
F 2
x
N
E
05
5 (S
BO
) EA
1.02
Com
men
ts 1
thro
ugh
4 fo
r the
sam
ple
ques
tion
wer
e in
corp
orat
ed.
How
ever
, the
follo
win
g fla
ws
exis
t for
the
revi
sed
ques
tion:
1.
Ste
m F
ocus
: B
oth
of th
e fil
l-in-
the-
blan
k st
atem
ents
con
tain
E
OP
-6.0
; sug
gest
re-w
ritin
g th
e st
em q
uest
ion
to in
clud
e E
OP
-6.
0.
2.
Ste
m F
ocus
: Th
e 1st
fill-
in-th
e-bl
ank
stat
emen
t sho
uld
bette
r cl
arify
that
PU
LL T
O L
K N
ON
-A is
a s
witc
h po
sitio
n, a
nd a
lso
the
phra
se “w
ill b
e im
plem
ente
d” s
houl
d be
cha
nged
to “i
s re
quire
d to
be
impl
emen
ted.
” S
ugge
st th
e fo
llow
ing:
“Atta
chm
ent 1
, Loc
al S
tarti
ng a
nd L
oadi
ng D
iese
l Gen
erat
or
A(B
) is
requ
ired
to b
e im
plem
ente
d __
(1)_
_ th
e sw
itche
s fo
r lo
ads
on B
uses
1D
A a
nd 1
DB
are
pla
ced
in th
e P
ULL
TO
LK
N
ON
-A p
ositi
on.”
3.
4-17
-18:
Com
men
ts in
corp
orat
ed; q
uest
ion
is S
AT.
Q
# 1.
LO
K
(F/H
)
2.
LOD
(1
-5)
3. P
sych
omet
ric F
law
s 4.
Job
Con
tent
Fla
ws
5. O
ther
6.
S
ourc
e B
/M/N
7.
Sta
tus
U/E
/S
8.
Exp
lana
tion
Ste
m
Focu
s C
ues
T/F
Cre
d.
Dis
t. P
artia
l Jo
b-Li
nk
Min
utia
#/
un
its
Bac
k-w
ard
Q=
K/A
S
RO
O
nly
11
H
2 x
x
x
N
E
057
(Los
s of
Vita
l AC
Inst
Bus
- EO
P s
trate
gies
) A
G2.
4.6
1.
Par
tial:
In th
e po
st-e
xam
app
eal s
pace
, an
appl
ican
t can
su
cces
sful
ly a
rgue
that
Cho
ice
C w
as n
ot e
ntire
ly c
orre
ct
beca
use
the
2nd s
tem
bul
let (
“A” T
rain
Wor
k W
eek)
doe
sn’t
nece
ssar
ily m
ean
that
the
seco
nd c
harg
ing
pum
p w
asn’
t av
aila
ble.
Ste
p 5
of A
ttach
men
t 3 re
quire
s st
artin
g bo
th
Cha
rgin
g P
umps
; Cho
ice
C s
ays
star
t one
Cha
rgin
g P
ump.
2.
Ste
m F
ocus
: C
hoic
e A
con
tain
s sl
ang,
i.e.
, “ba
cked
up.
” S
ugge
st re
visi
ng to
say
“Act
uate
SI u
sing
eith
er S
I Act
uatio
n S
witc
h.”
3.
Ste
m F
ocus
: Th
e ph
rase
“an
item
” in
the
stem
que
stio
n is
va
gue,
and
eac
h ch
oice
incl
udes
the
phra
se “w
ill b
e”; s
ugge
st
revi
sing
the
stem
que
stio
n an
d ea
ch c
hoic
e to
acc
omm
odat
e th
e ph
rase
“is
requ
ired”
in e
ach
choi
ce a
s fo
llow
s:
WO
OTF
is a
requ
ired
man
ual a
ctio
n th
at m
ust b
e pe
rform
ed
whi
le a
n op
erat
or is
per
form
ing
Atta
chm
ent 3
, SI E
quip
men
t V
erifi
catio
n?
A.
Act
uate
SI u
sing
eith
er S
I Act
uatio
n S
witc
h.
B.
Pla
ce a
SW
Boo
ster
Pum
p S
witc
h in
the
PU
LL T
O L
OC
K
NO
N A
pos
ition
. C
. S
tart
one
Cha
rgin
g P
ump
D.
Sta
rt on
e R
B S
pray
Pum
p
4.
#/un
its:
The
noun
nam
e (1
20 V
olt V
ital A
C D
istri
butio
n P
anel
1
NS
SS
) is
mis
sing
from
the
3rd s
tem
bul
let.
5.
Not
e: O
ne o
ptio
n is
to te
st F
SP
-7.0
, Los
s of
Vita
l In
stru
men
tatio
n or
Con
trol P
ower
.
6.
4-19
-18:
Com
men
ts in
corp
orat
ed; q
uest
ion
is S
AT.
Q
# 1.
LO
K
(F/H
)
2.
LOD
(1
-5)
3. P
sych
omet
ric F
law
s 4.
Job
Con
tent
Fla
ws
5. O
ther
6.
S
ourc
e B
/M/N
7.
Sta
tus
U/E
/S
8.
Exp
lana
tion
Ste
m
Focu
s C
ues
T/F
Cre
d.
Dis
t. P
artia
l Jo
b-Li
nk
Min
utia
#/
un
its
Bac
k-w
ard
Q=
K/A
S
RO
O
nly
12
H
2 x
x
x
N
U
T1G
1 0
58 (L
oss
of D
C P
ower
-exe
cute
pro
cedu
re s
teps
) AG
2.1.
20
1.
Q=K
/A:
The
K/A
is “A
bilit
y to
exe
cute
pro
cedu
re s
teps
.” T
he
prop
osed
test
item
doe
sn’t
test
the
appl
ican
ts’ k
now
ledg
e of
pr
oced
ures
; it c
an b
e an
swer
ed b
y kn
owin
g th
at L
CV
-459
aut
o-is
olat
es w
hen
DC
con
trol c
ircui
t pow
er is
rem
oved
, and
then
ex
cess
letd
own
(Cho
ice
A) i
s re
quire
d du
e to
risi
ng p
ress
uriz
er
leve
l.
2.
Cre
d D
ist:
Cho
ice
B (o
pen
LCV
-460
) is
not p
laus
ible
bec
ause
it
is in
ser
ies
with
LC
V-4
59.
3.
Ste
m F
ocus
: Th
e 3rd
bul
let i
s no
t nec
essa
ry.
4.
Ste
m F
ocus
: Th
e 2nd
ste
m b
ulle
t may
indi
cate
that
the
DC
co
ntro
l circ
uit f
use
was
blo
wn;
wha
t cau
sed
the
“ope
n ci
rcui
t” in
th
e 2nd
ste
m b
ulle
t?
5.
Ste
m F
ocus
: Th
e st
em q
uest
ion
shou
ld s
peci
fy w
hich
pr
oced
ure
cont
ains
the
requ
ired
actio
n.
6.
Not
e: F
acili
ty li
cens
ee m
ay n
ot h
ave
an a
bnor
mal
con
ditio
n pr
oced
ure
for l
oss
of D
C p
ower
.
Q
# 1.
LO
K
(F/H
)
2.
LOD
(1
-5)
3. P
sych
omet
ric F
law
s 4.
Job
Con
tent
Fla
ws
5. O
ther
6.
S
ourc
e B
/M/N
7.
Sta
tus
U/E
/S
8.
Exp
lana
tion
Ste
m
Focu
s C
ues
T/F
Cre
d.
Dis
t. P
artia
l Jo
b-Li
nk
Min
utia
#/
un
its
Bac
k-w
ard
Q=
K/A
S
RO
O
nly
13
H
2 x
x
x x
N
E
SA
MP
LE Q
UE
STI
ON
RE
CE
IVE
D 1
2-19
-17
T1G
1 0
62 (
Loss
of N
ucle
ar S
W) A
K3.
04
1.
Par
tial:
Dur
ing
a po
st-e
xam
app
eal,
an a
pplic
ant c
an
succ
essf
ully
arg
ue th
at C
hoic
e A
(RC
P tr
ip is
requ
ired)
is a
lso
corr
ect b
ecau
se S
tep
16 o
f AO
P-1
17.1
(Los
s of
SW
) req
uire
s tri
ppin
g th
e R
CP
whe
n hi
gh b
earin
g te
mpe
ratu
res
exis
t. Th
ere
is
no c
oolin
g to
CC
W; t
here
fore
it is
imm
inen
t tha
t hig
h R
CP
be
arin
g te
mpe
ratu
res
will
occ
ur.
2.
Cre
d D
ist:
Sin
ce n
o in
itial
pow
er le
vel i
s sp
ecifi
ed in
the
stem
, C
hoic
e B
(red
uce
pow
er) i
s no
t pla
usib
le.
3.
Ste
m F
ocus
: Th
e 2nd
hal
f of e
ach
choi
ce is
not
bei
ng te
sted
(or
need
ed) s
ince
the
1st p
art o
f eac
h ch
oice
is u
niqu
e. I
n ot
her
wor
ds, t
he a
pplic
ant o
nly
need
s to
kno
w th
e re
quire
d ac
tion.
(T
estin
g on
ly th
e 1st
par
t of t
he q
uest
ion
does
, how
ever
, in
dire
ctly
test
the
reas
on.
For e
xam
ple,
Loc
al C
harg
ing
Pum
p Te
mpe
ratu
re M
onito
ring
is th
e re
quire
d ac
tion.
Rea
son
is
indi
rect
ly b
eing
test
ed –
bec
ause
CC
W h
as n
o co
olin
g).
4.
Cue
: “M
onito
ring”
is a
lway
s a
safe
, cor
rect
act
ion,
and
als
o th
e co
rrec
t ans
wer
; sug
gest
re-w
ordi
ng C
hoic
e C
(cor
rect
ans
wer
) as
:
“Loc
ally
per
form
Atta
chm
ent 3
, Cha
rgin
g P
ump
Tem
pera
ture
M
onito
ring.
”
5.
Ste
m F
ocus
: Th
e 4th
bul
let i
n th
e st
em is
not
nec
essa
ry.
6.
Ste
m F
ocus
: To
ens
ure
that
Cho
ice
B (r
apid
pow
er re
duct
ion)
m
irror
s th
e X
CP
-632
, 3-6
requ
irem
ent,
sugg
est r
e-w
ordi
ng
Cho
ice
B to
: “R
educ
e lo
ad to
zer
o w
ithin
1 h
our.”
7.
NO
TE:
K/A
(AK
3.04
, Kno
wle
dge
of th
e re
ason
s fo
r the
follo
win
g re
spon
ses
as th
ey a
pply
to th
e Lo
ss o
f Nuc
lear
Ser
vice
Wat
er:
“Effe
ct o
n th
e nu
clea
r ser
vice
wat
er d
isch
arge
flow
hea
der
of a
loss
of C
CW
”) is
poo
rly w
orde
d. A
loss
of C
CW
doe
s no
t af
fect
the
nucl
ear s
ervi
ce w
ater
“flo
w h
eade
r”; s
ervi
ce w
ater
co
ols
CC
W.
The
K/A
mak
es s
ense
if th
e w
ordi
ng in
tent
was
:
Kno
wle
dge
of th
e re
ason
s fo
r the
follo
win
g re
spon
ses
as th
ey
appl
y to
the
Loss
of N
ucle
ar S
ervi
ce W
ater
: “E
ffect
of a
loss
of
the
nucl
ear s
ervi
ce w
ater
dis
char
ge fl
ow h
eade
r on
CC
W”,
or m
ore
sim
ply
put:
Effe
ct o
n C
CW
.
The
prop
osed
que
stio
n do
es te
st th
e ef
fect
of a
loss
of n
ucle
ar
SW
on
CC
W. (
char
ging
pum
p no
coo
ling;
mon
itorin
g re
quire
d);
ther
efor
e th
e in
tent
of t
he K
/A m
atch
is a
ccep
tabl
e.
Q
# 1.
LO
K
(F/H
)
2.
LOD
(1
-5)
3. P
sych
omet
ric F
law
s 4.
Job
Con
tent
Fla
ws
5. O
ther
6.
S
ourc
e B
/M/N
7.
Sta
tus
U/E
/S
8.
Exp
lana
tion
Ste
m
Focu
s C
ues
T/F
Cre
d.
Dis
t. P
artia
l Jo
b-Li
nk
Min
utia
#/
un
its
Bac
k-w
ard
Q=
K/A
S
RO
O
nly
13
F 2
N
S
06
2 (L
oss
Nuc
SW
-rea
sons
effe
ct o
f los
s of
CC
W o
n S
W)
AK
3.04
Sam
ple
ques
tion
com
men
ts in
corp
orat
ed.
14
x
x
x
N
E
07
7 (G
en V
olta
ge &
Grid
-ope
rato
r/mon
itor E
SFs
) A
A1.
05
1.
Par
tial:
Eac
h an
swer
cho
ice
shou
ld s
tand
on
its o
wn,
with
out
requ
iring
the
appl
ican
t to
com
pare
one
ans
wer
cho
ice
to
anot
her.
Tec
hnic
ally
, Cho
ice
A is
not
ent
irely
cor
rect
sin
ce o
ther
pl
ant a
ctua
tions
(bey
ond
the
scop
e of
this
que
stio
n) o
ccur
red
whe
n th
e “A
” ED
G a
uto-
star
ted.
How
ever
, sin
ce C
hoic
e A
use
s th
e w
ord
“Onl
y”, a
n ap
plic
ant c
an s
ucce
ssfu
lly c
onte
nd th
at
ther
e is
no
abso
lute
cor
rect
ans
wer
, but
inst
ead,
one
ans
wer
th
at is
“bet
ter”
than
the
othe
rs.
”Cho
ice
C is
con
fusi
ng b
ecau
se it
is th
e on
ly c
hoic
e th
at g
oes
“into
the
futu
re.”
Sug
gest
re-w
orki
ng th
e st
em q
uest
ion
and
choi
ces
to p
rese
nt
the
info
rmat
ion
in a
noth
er w
ay th
at fo
cuse
s on
thre
e as
pect
s (A
E
DG
, B E
DG
, and
C R
CP
), so
that
eac
h an
swer
cho
ice
stan
ds
on it
s ow
n m
erit.
For
exa
mpl
e:
WO
OTF
iden
tifie
s th
e pl
ant r
espo
nse?
A.
“A” E
DG
aut
o-st
arte
d, “B
” ED
G d
id n
ot a
uto-
star
t, “C
” RC
P
is ru
nnin
g.
B.
“A” a
nd “B
” ED
Gs
auto
-sta
rted;
“C” R
CP
is ru
nnin
g
C.
No
ED
Gs
have
aut
o-st
arte
d; “C
” RC
P is
runn
ing
D.
“A” E
DG
aut
o-st
arte
d, “B
” ED
G d
id n
ot a
uto-
star
t, “C
” RC
P
tripp
ed.
2.
Ste
m F
ocus
: Th
e 3rd
bul
let i
s no
t nec
essa
ry; r
efer
to O
L Fe
edba
ck It
em 4
01.5
5.
3.
Ste
m F
ocus
: Th
e 2nd
and
5th b
ulle
ts a
re n
ot n
eces
sary
.
4.
LOK
: Th
is te
st it
em s
eem
s to
be
high
er c
og; l
et’s
dis
cuss
.
5.
4-17
-18:
Com
men
ts in
corp
orat
ed; q
uest
ion
is S
AT.
Q
# 1.
LO
K
(F/H
)
2.
LOD
(1
-5)
3. P
sych
omet
ric F
law
s 4.
Job
Con
tent
Fla
ws
5. O
ther
6.
S
ourc
e B
/M/N
7.
Sta
tus
U/E
/S
8.
Exp
lana
tion
Ste
m
Focu
s C
ues
T/F
Cre
d.
Dis
t. P
artia
l Jo
b-Li
nk
Min
utia
#/
un
its
Bac
k-w
ard
Q=
K/A
S
RO
O
nly
15
? 2
x
x
N
E
W
E04
(LO
CA
o/s
Cnm
t-) E
K2.
2
1.
Par
tial:
Sin
ce th
e in
itial
pla
nt c
ondi
tions
are
n’t p
rovi
ded,
the
first
m
anua
l val
ve o
pera
tion
requ
ired
by E
OP
-2.5
may
not
be
a ch
oice
. Fo
r exa
mpl
e, S
tep
2.a
requ
ires
clos
ing
the
RH
R
Suc
tion
valv
es fr
om th
e R
CS
. If
shut
dow
n co
olin
g w
as in
itial
ly
in s
ervi
ce, t
here
cou
ld b
e no
cor
rect
ans
wer
.
2.
Ste
m F
ocus
: Th
e 2nd
bul
let i
s va
gue
or m
ay n
ot b
e ne
cess
ary.
A
ll au
to-M
OV
act
uatio
ns th
at o
ccur
red
as a
resu
lt of
the
LOC
A
in th
e A
ux B
ldg
(prio
r to
MV
G-8
888A
) occ
urre
d as
a re
sult
of a
pl
ant p
aram
eter
that
exc
eede
d so
me
set p
oint
. If
the
prio
r aut
o-ac
tuat
ions
are
rele
vant
to th
e qu
estio
n, th
en th
e pl
ant
para
met
er(s
) sho
uld
be li
sted
in th
e st
em.
If th
e pl
ant
para
met
ers
aren
’t re
leva
nt, t
hen
the
2nd b
ulle
t isn
’t ne
cess
ary.
Fo
r exa
mpl
e, d
id L
etdo
wn
auto
-isol
ate
as a
resu
lt of
low
pr
essu
rizer
leve
l?
3.
Ste
m F
ocus
: Th
e 4th
bul
let s
houl
d in
clud
e th
e w
ord
“man
ual”,
e.
g., “
The
first
man
ual c
losu
re o
f a M
OV
.”
4.
Ste
m F
ocus
: Th
e w
ord
“had
” (in
the
4th b
ulle
t) sh
ould
be
“has
.”
5.
Con
side
r pro
vidi
ng a
n in
itial
pla
nt c
ondi
tion
that
add
s pl
ausi
bilit
y to
the
RH
R S
uctio
n va
lves
from
the
RC
S b
eing
ope
n, a
nd
incl
ude
thes
e va
lves
as
one
of th
e ch
oice
s.
6.
LOK
: R
e-vi
sit t
he L
OK
afte
r res
olut
ion
of c
omm
ents
list
ed
abov
e; d
iscu
ss.
7.
4-17
-18:
Com
men
ts in
corp
orat
ed; q
uest
ion
is S
AT.
Q
# 1.
LO
K
(F/H
)
2.
LOD
(1
-5)
3. P
sych
omet
ric F
law
s 4.
Job
Con
tent
Fla
ws
5. O
ther
6.
S
ourc
e B
/M/N
7.
Sta
tus
U/E
/S
8.
Exp
lana
tion
Ste
m
Focu
s C
ues
T/F
Cre
d.
Dis
t. P
artia
l Jo
b-Li
nk
Min
utia
#/
un
its
Bac
k-w
ard
Q=
K/A
S
RO
O
nly
16
H
3 x
x
x
N
E
T1G
1 W
E05
(Los
s of
Sec
onda
ry H
eat S
ink)
EK
1.3
1.
Par
tial:
Cho
ice
A (
EO
P-1
5.0
entry
afte
r add
ition
al 7
%) i
s al
so
corr
ect b
ecau
se E
OP
-15.
0 en
try w
ould
STI
LL b
e re
quire
d ev
en
afte
r NR
SG
leve
ls d
ecre
ased
an
addi
tiona
l 7%
.
2.
Cue
: Th
e 2nd
par
t of C
hoic
es A
/C c
ue th
e ap
plic
ant t
o th
e E
OP
-12
.0, A
ttach
men
t 3, H
eat S
ink,
non
-adv
erse
con
tain
men
t val
ue
for N
R S
G le
vel,
whi
ch in
dire
ctly
cue
s th
e ap
plic
ant t
hat a
dver
se
cont
ainm
ent v
alue
s ar
e in
effe
ct.
S
ugge
st re
-wor
king
the
2nd p
art o
f the
que
stio
n to
test
whe
ther
a
Hea
t Sin
k R
ed P
ath
does
/doe
s N
OT
exis
t at t
his
time.
3.
Cue
: Th
e ph
rase
“and
dec
reas
ing”
in th
e 9th
bul
let (
Tim
e 12
17)
is n
ot n
eces
sary
to e
licit
the
corr
ect r
espo
nse.
4.
Ste
m F
ocus
: Th
e st
em q
uest
ion
refe
rs to
two
stat
emen
ts e
ven
thou
gh th
ere
is o
nly
one
fill-i
n-th
e-bl
ank
stat
emen
t.
5.
Ste
m F
ocus
: Th
e bo
lded
and
und
erlin
ed s
ente
nce
abou
t as
sum
ing
no o
ther
RE
D p
aths
are
pre
sent
on
the
CS
FSTs
is n
ot
nece
ssar
y; A
ppen
dix
E b
riefin
g w
ill e
nsur
e ap
plic
ants
un
ders
tand
.
6.
Ste
m F
ocus
: Th
e 2nd
par
t of C
hoic
es A
/C c
onta
ins
a re
dund
ant
wor
d, i.
e., N
R ra
nge.
7.
4-17
-18:
Com
men
ts in
corp
orat
ed; q
uest
ion
is S
AT.
Q
# 1.
LO
K
(F/H
)
2.
LOD
(1
-5)
3. P
sych
omet
ric F
law
s 4.
Job
Con
tent
Fla
ws
5. O
ther
6.
S
ourc
e B
/M/N
7.
Sta
tus
U/E
/S
8.
Exp
lana
tion
Ste
m
Focu
s C
ues
T/F
Cre
d.
Dis
t. P
artia
l Jo
b-Li
nk
Min
utia
#/
un
its
Bac
k-w
ard
Q=
K/A
S
RO
O
nly
17
H
2 x
x
x x
x
B
E
T1G
1 W
E11
(Los
s of
Em
erg
Rec
irc-p
roce
dure
s) E
K1.
2
1.
Job-
Link
: Th
e se
cond
par
t of t
he te
st it
em te
sts
RO
app
lican
ts’
know
ledg
e of
the
EO
P b
ases
for S
tep
9.d
of E
OP
-2.4
. Th
e S
RO
Cla
rific
atio
n G
uida
nce
Doc
umen
t (E
S-4
01, A
ttach
men
t 2)
is s
ilent
on
whe
ther
EO
P b
ases
kno
wle
dge
is S
RO
or R
O
know
ledg
e. T
he le
arni
ng o
bjec
tive
(STA
TE th
e m
ajor
act
ion
cate
gorie
s of
EO
P-2
.4) d
oes
not j
ustif
y te
stin
g th
e R
O
appl
ican
ts’ k
now
ledg
e of
the
EO
P b
ases
; the
refo
re, t
his
test
ite
m is
vul
nera
ble
to a
pos
t-exa
m a
ppea
l. S
ugge
st te
stin
g a
requ
ired
man
ual o
pera
tor a
ctio
n in
EO
P-2
.4.
2.
Par
tial a
nd/o
r Cre
d D
ist:
Cho
ice
A (p
ump
prot
ectio
n +
cont
ainm
ent i
sola
tion)
can
suc
cess
fully
be
argu
ed a
s co
rrec
t be
caus
e th
e st
em q
uest
ion
does
not
ask
in a
ccor
danc
e w
ith th
e em
erge
ncy
proc
edur
e gu
idel
ines
; sto
ppin
g th
e pu
mp
befo
re it
lo
ses
suct
ion
can
be a
cor
rect
ans
wer
. O
n th
e ot
her h
and,
the
stem
indi
cate
s a
LB L
OC
A, w
ith n
o co
ntai
nmen
t pre
ssur
e pr
ovid
ed; t
here
fore
, the
pla
usib
ility
of p
rote
ctin
g a
pum
p is
qu
estio
nabl
e.
3.
Cue
: Th
e 5th
bul
let i
s no
t nec
essa
ry to
elic
it th
e co
rrec
t re
spon
se.
4.
Ste
m F
ocus
: In
the
1st b
ulle
t, th
e ph
rase
“Los
s of
Coo
lant
A
ccid
ent”
is s
pelle
d ou
t eve
n th
ough
this
form
at is
not
use
d in
ot
her t
est i
tem
s lik
e Q
#3 a
nd Q
#4.
Nee
d to
be
cons
iste
nt
thou
gh o
ut th
e en
tire
exam
.
5.
Ens
ure
no o
verla
p w
ith S
RO
Q#8
3, a
nd R
O Q
#41.
6.
4-20
-18:
Com
men
ts in
corp
orat
ed; q
uest
ion
is S
AT.
Q
# 1.
LO
K
(F/H
)
2.
LOD
(1
-5)
3. P
sych
omet
ric F
law
s 4.
Job
Con
tent
Fla
ws
5. O
ther
6.
S
ourc
e B
/M/N
7.
Sta
tus
U/E
/S
8.
Exp
lana
tion
Ste
m
Focu
s C
ues
T/F
Cre
d.
Dis
t. P
artia
l Jo
b-Li
nk
Min
utia
#/
un
its
Bac
k-w
ard
Q=
K/A
S
RO
O
nly
18
F 2
x
x
N
U
T1
G1
WE
12 (
SL
Rup
ture
-exc
ess
Hea
t Xfe
r) E
K3.
1
1.
Q=K
/A:
Non
e of
the
info
rmat
ion
abov
e th
e st
em q
uest
ion
is
nece
ssar
y to
ans
wer
the
ques
tion;
the
prop
osed
test
item
is
esse
ntia
lly:
WO
OTF
com
plet
es th
e fo
llow
ing
stat
emen
ts IA
W E
OP
-12.
0,
Atta
chm
ent 4
, Int
egrit
y?
The
high
est T
cold
tem
pera
ture
val
ue th
at re
quire
s en
try to
a
Red
Pat
h is
___
__.
The
reas
on fo
r CS
FST
Inte
grity
pro
cedu
re is
to e
nsur
e th
at
____
__.
Ther
efor
e, th
e pr
opos
ed te
st it
em te
sts
Ven
dor S
peci
fic
Em
erge
ncy
Evo
lutio
n To
pic
E08
, Pre
ssur
ized
The
rmal
Sho
ck,
inst
ead
of te
stin
g th
e W
E12
, Unc
ontro
lled
Dep
ress
uriz
atio
n of
A
ll S
Gs,
topi
c. T
he p
ropo
sed
ques
tion
does
not
test
any
thin
g fro
m E
OP
-3.1
.
2.
Ste
m F
ocus
: It
may
be
mor
e ap
prop
riate
for t
he 1
st 1
440
bulle
t to
be
EO
P-3
.0, E
-2 F
aulte
d S
G Is
olat
ion.
3.
Ste
m F
ocus
: Th
e 1st
fill-
in-th
e-bl
ank
stat
emen
t con
tain
s sl
ang,
i.e
., “le
ave
EO
P-3
.1”;
sugg
est r
e-w
orki
ng in
to w
hen
entry
to a
R
ed P
ath
is re
quire
d.
4.
Ste
m F
ocus
: Th
e bo
lded
and
und
erlin
ed s
tate
men
t abo
ut
gree
n C
SFS
Ts is
not
nec
essa
ry.
5.
4-23
-18:
Rew
rote
que
stio
n; n
ew q
uest
ion
is S
AT.
Q
# 1.
LO
K
(F/H
)
2.
LOD
(1
-5)
3. P
sych
omet
ric F
law
s 4.
Job
Con
tent
Fla
ws
5. O
ther
6.
S
ourc
e B
/M/N
7.
Sta
tus
U/E
/S
8.
Exp
lana
tion
Ste
m
Focu
s C
ues
T/F
Cre
d.
Dis
t. P
artia
l Jo
b-Li
nk
Min
utia
#/
un
its
Bac
k-w
ard
Q=
K/A
S
RO
O
nly
19
F 2
x
x
B
E
T1
G2
001
(Con
tinuo
us R
od W
ithdr
awal
-rod
in-o
ut-s
witc
h) A
A1.
02
1.
Cre
d D
ist:
Cho
ice
D (p
erfo
rm b
orat
ion
whi
le ’r
efer
ring”
inst
ead
of u
sing
pro
cedu
re) i
s no
t pla
usib
le b
ecau
se th
e ph
rase
“whi
le
refe
rrin
g to
” im
plie
s th
at p
roce
dure
-use
is o
ptio
nal d
urin
g an
ab
norm
al e
volu
tion.
2.
Ste
m F
ocus
: It
appe
ars
that
eve
ryth
ing
abov
e th
e st
em
ques
tion
is n
ot n
eces
sary
if th
e st
em q
uest
ion
is w
orde
d as
:
“WO
OTF
is th
e fir
st m
etho
d us
ed fo
r adj
ustin
g Ta
vg in
ac
cord
ance
with
AO
P-4
03.3
, CO
NTI
NU
OU
S R
OD
MO
TIO
N,
afte
r all
imm
edia
te o
pera
tor a
ctio
ns a
re c
ompl
eted
?”
3.
Ste
m F
ocus
: Th
e In
itial
Con
ditio
ns s
houl
d sa
y th
at T
avg
and
Tref
are
mat
ched
.
4.
Ste
m F
ocus
: Th
e 2nd
bul
let,
as w
ell a
s C
hoic
es A
& B
, sho
uld
refe
r to
the
RO
D C
ON
TRL
BA
NK
SE
L S
witc
h be
ing
in e
ither
the
AU
TO/M
AN
/ or C
BD
pos
ition
. Fo
r exa
mpl
e:
“Con
trol R
od B
ank
“D” r
ods
bega
n st
eppi
ng o
ut w
ith th
e R
OD
C
ON
TRL
BA
NK
SE
L S
witc
h w
as in
the
AU
TO p
ositi
on.”
5.
Ste
m F
ocus
: Th
e ph
rase
“tha
t will
be”
in th
e st
em q
uest
ion
is
not n
eces
sary
.
6.
Ste
m F
ocus
: S
ugge
st u
sing
the
wor
d “in
itial
” ins
tead
of “
pre-
inci
dent
” pos
ition
in th
e 6th
bul
let.
7.
4-17
-18:
Com
men
t #2
is N
/A b
ecau
se ro
ds/b
orat
ion
with
te
mpe
ratu
re c
hang
es is
nee
ded.
All
othe
r com
men
ts
inco
rpor
ated
; que
stio
n is
SA
T.
Q
# 1.
LO
K
(F/H
)
2.
LOD
(1
-5)
3. P
sych
omet
ric F
law
s 4.
Job
Con
tent
Fla
ws
5. O
ther
6.
S
ourc
e B
/M/N
7.
Sta
tus
U/E
/S
8.
Exp
lana
tion
Ste
m
Focu
s C
ues
T/F
Cre
d.
Dis
t. P
artia
l Jo
b-Li
nk
Min
utia
#/
un
its
Bac
k-w
ard
Q=
K/A
S
RO
O
nly
20
H
1 x
x
x x
M
U
E
036
(Fue
l Han
dlin
g A
ccid
ent-g
uida
nce
in E
OP
) A
K3.
03
1.
Cre
d D
ist:
Cho
ices
C/D
(car
t sta
ys in
RB
) is
not p
laus
ible
be
caus
e th
e st
em s
ays
the
cart
is a
lread
y in
the
RB
and
the
wor
ding
of t
he 1
st fi
ll-in
-the-
blan
k st
atem
ent s
ays
the
cart
“will
be
mov
ed to
the
___(
1)__
_.”
Ther
efor
e, a
n ap
plic
ant c
an d
educ
e th
at s
ince
the
fill-i
n-th
e-bl
ank
stat
emen
t say
s m
ovem
ent i
s re
quire
d, th
en th
e ca
rt m
ust g
o to
the
FHB
.
2.
Cue
and
/or L
OD
=1:
The
4th b
ulle
t is
not n
eces
sary
to e
licit
the
corr
ect r
espo
nse;
it g
ives
aw
ay th
e 1st
par
t of t
he q
uest
ion.
3.
Par
tial:
Bas
ed o
n st
em c
ondi
tions
and
AO
P-1
23.3
, Ste
p 1,
the
next
requ
ired
step
is S
tep
6 be
caus
e th
e fu
el a
ssem
bly
is n
ot
stuc
k an
d no
ne o
f the
radi
atio
n m
onito
rs a
re a
larm
ing.
Th
eref
ore,
ther
e is
no
corr
ect a
nsw
er to
the
ques
tion
beca
use
the
Fuel
Tra
nsfe
r Car
t is
not r
equi
red
to b
e se
nt to
the
Fuel
H
andl
ing
Bui
ldin
g; a
fter S
tep
6, th
e ne
xt re
quire
d st
ep is
Ste
p 10
to
sta
rt C
RE
V.
Sug
gest
add
ing
a bu
llet t
o th
e st
em fo
r eith
er a
st
uck
rod
or a
larm
ing
radi
atio
n m
onito
r to
ensu
re th
at S
tep
4.b
is
requ
ired.
4.
Cre
d D
ist:
Cho
ice
C (c
art s
tays
in R
B to
allo
w c
losu
re o
f tub
e va
lve)
is n
ot p
laus
ible
bec
ause
the
fuel
tran
sfer
val
ve c
an b
e cl
osed
eve
n if
the
cart
is m
oved
to th
e FH
B.
5.
Ste
m F
ocus
: S
ugge
st re
wor
ding
the
2nd p
art o
f Cho
ice
D a
s:
“ens
ure
the
dam
aged
ass
embl
y re
mai
ns in
the
upen
der.”
6.
Com
men
t #1
is N
/A b
ecau
se w
here
fuel
han
dlin
g ca
rt w
as
initi
ally
loca
ted
is ir
rele
vant
to k
now
ledg
e be
ing
test
ed.
Q
# 1.
LO
K
(F/H
)
2.
LOD
(1
-5)
3. P
sych
omet
ric F
law
s 4.
Job
Con
tent
Fla
ws
5. O
ther
6.
S
ourc
e B
/M/N
7.
Sta
tus
U/E
/S
8.
Exp
lana
tion
Ste
m
Focu
s C
ues
T/F
Cre
d.
Dis
t. P
artia
l Jo
b-Li
nk
Min
utia
#/
un
its
Bac
k-w
ard
Q=
K/A
S
RO
O
nly
21
F 2
x
x
x
N
E
03
7 (S
GTL
-flow
rate
of l
eak)
AA
2.12
1.
This
test
item
ove
rlaps
with
Sce
nario
2, E
vent
6; t
he c
rew
will
en
ter a
nd u
se A
OP
-112
.2, t
he s
cena
rio le
ak ra
te a
lso
invo
lves
A
ttach
men
t 3, P
lant
Shu
tdow
n R
equi
rem
ents
Bas
ed o
n R
MA
-9
Eva
luat
ion.
Rep
lace
test
item
or E
vent
6.
2.
Par
tial:
To
ensu
re th
e qu
estio
n is
has
a c
orre
ct a
nsw
er, r
e-w
ord
the
stem
que
stio
n as
:
“WO
OTF
com
plet
es b
oth
stat
emen
ts in
acc
orda
nce
with
AO
P-
112.
2?
3.
#/un
its:
The
1st fi
ll-in
-the-
blan
k st
atem
ent i
s m
issi
ng th
e no
un
nam
e of
the
com
pute
r cal
cula
tion.
Sug
gest
rew
ordi
ng a
s:
“The
IPC
S C
ompu
ter P
oint
use
d to
eva
luat
e sh
utdo
wn
requ
irem
ents
is b
ased
on
radi
atio
n m
easu
red
by _
_(1)
___
.”
4.
Ste
m F
ocus
: Th
e 5th
bul
let i
s no
t nec
essa
ry b
ecau
se th
e 2nd
fill-
in-th
e-bl
ank
stat
emen
t has
the
wor
d bo
lded
and
und
erlin
ed.
5.
Ste
m F
ocus
: Th
e st
em q
uest
ion
refe
rs to
the
fill-i
n-th
e-bl
ank
stat
emen
ts a
s “q
uest
ions
.”
6.
4-5-
18:
Rep
lace
d K
/A w
ith 0
37 A
A2.
08, F
ailu
re o
f Con
dens
er
Air
Eje
ctor
Exh
aust
Mon
itor (
RM
-A9)
to b
e di
ffere
nt fr
om
scen
ario
s.
22
x
x
B
U
06
8 (C
R E
vacu
atio
n-lo
cal b
oric
aci
d flo
w)
AA
2.02
1.
Cre
d D
ist:
The
1st p
art o
f Cho
ices
C/D
(per
form
SD
M
calc
ulat
ion
whi
le e
vacu
atin
g co
ntro
l roo
m) i
s no
t pla
usib
le
beca
use
neith
er th
e da
ta n
or th
e tim
e fo
r a S
DM
cal
cula
tion
is
avai
labl
e af
ter t
he c
ontro
l roo
m h
as b
een
evac
uate
d.
2.
Cue
: P
rovi
ding
the
nam
e of
Ste
p 4
in th
e 4th
ste
m b
ulle
t, as
wel
l as
pro
vidi
ng th
e ph
rase
“gra
vity
dra
in a
lignm
ent”
in th
e 2nd
fill-
in-
the-
blan
k st
atem
ent,
is n
ot n
eces
sary
to e
licit
the
corr
ect
resp
onse
. P
er A
OP
-600
.1, S
tep
12 o
f AO
P-1
06.1
is a
n R
NO
on
ly w
hen
EM
ER
G B
A F
LOW
GP
M F
T-11
0A is
not
ava
ilabl
e.
Ther
e is
no
need
to “r
efer
” to
AO
P-1
06.1
.
3.
4-23
-18:
Re-
wor
ked
first
hal
f of q
uest
ion
to te
st [B
] req
uire
d fo
r 2
rods
and
3 ro
ds.
Com
men
t #2
is N
/A b
ecau
se th
e ot
her
choi
ce a
lso
has
a su
ctio
n va
lve
alig
nmen
t. Q
uest
ion
is S
AT.
Q
# 1.
LO
K
(F/H
)
2.
LOD
(1
-5)
3. P
sych
omet
ric F
law
s 4.
Job
Con
tent
Fla
ws
5. O
ther
6.
S
ourc
e B
/M/N
7.
Sta
tus
U/E
/S
8.
Exp
lana
tion
Ste
m
Focu
s C
ues
T/F
Cre
d.
Dis
t. P
artia
l Jo
b-Li
nk
Min
utia
#/
un
its
Bac
k-w
ard
Q=
K/A
S
RO
O
nly
23
x
x
x
x
N
E
T1
G2
WE
03 (L
OC
A C
oold
own
– D
epre
ss)
EK
2.2
1.
Cre
d D
ist:
Cho
ice
D (S
tart
3 R
CP
s) is
not
pla
usib
le b
ecau
se
ther
e is
no
Wes
tingh
ouse
EO
P th
at s
tarts
all
3 R
CP
s, e
spec
ially
af
ter a
SB
LO
CA
.
2.
Cue
and
/or C
red
Dis
t: T
he la
st b
ulle
t in
the
stem
is n
ot
nece
ssar
y to
elic
it th
e co
rrec
t res
pons
e (p
oint
s aw
ay fr
om
Cho
ice
A) a
nd/o
r the
last
bul
let i
njur
es th
e cr
edib
ility
of C
hoic
e A
. E
ven
thou
gh E
OP
-2.1
, Ste
p 9.
d.1
dire
cts
the
crew
to re
fer t
o S
OP
-101
, the
test
item
can
be
cons
truct
ed w
ithou
t inc
ludi
ng th
e la
st s
tem
bul
let b
y as
king
the
appl
ican
ts w
hat t
he R
CP
stra
tegy
is
for R
CP
s in
Pos
t-LO
CA
Coo
ldow
n &
Dep
ress
uriz
atio
n pr
oced
ure,
with
out t
he n
eed
for s
ayin
g S
OP
-101
requ
irem
ents
ar
e m
et.
3.
Cre
d D
ist:
The
re’s
not
hing
in th
e st
em th
at in
dica
tes
why
RC
P
“A” (
first
cho
ice
for s
pray
) isn
’t av
aila
ble;
to e
nhan
ce p
laus
ibili
ty
of C
hoic
e C
, sug
gest
incl
udin
g a
RC
P p
aram
eter
in th
e st
em,
whe
re R
CP
A h
as th
e lo
wes
t val
ue.
4.
Par
tial:
Re-
wor
d th
e st
em q
uest
ion
to s
ay “i
n ac
cord
ance
with
..”
inst
ead
of “d
urin
g th
e im
plem
enta
tion
of.”
5.
Ste
m F
ocus
: Th
e 4th
bul
let p
hras
e “in
the
inje
ctio
n m
ode”
is n
ot
nece
ssar
y.
6.
Ste
m F
ocus
: Th
e 3rd
bul
let c
an b
e sh
orte
ned
to s
ay:
“The
cre
w
is p
erfo
rmin
g E
OP
-2.1
, Pos
t-LO
CA
Coo
ldow
n an
d D
epre
ssur
izat
ion.
” Th
e ph
rase
“act
ions
con
tain
ed in
” is
not
nece
ssar
y.
7.
LOK
: Th
is te
st it
em a
ppea
rs to
be
high
er c
og; l
et’s
dis
cuss
.
8.
4-19
-18:
Com
men
t #1
is N
/A b
ecau
se E
OP
-14.
0 (In
adeq
uate
C
ore
Coo
ling)
sta
rts a
ll 3
RC
Ps.
Oth
er c
omm
ents
inco
rpor
ated
; qu
estio
n is
SA
T.
Q
# 1.
LO
K
(F/H
)
2.
LOD
(1
-5)
3. P
sych
omet
ric F
law
s 4.
Job
Con
tent
Fla
ws
5. O
ther
6.
S
ourc
e B
/M/N
7.
Sta
tus
U/E
/S
8.
Exp
lana
tion
Ste
m
Focu
s C
ues
T/F
Cre
d.
Dis
t. P
artia
l Jo
b-Li
nk
Min
utia
#/
un
its
Bac
k-w
ard
Q=
K/A
S
RO
O
nly
24
F 2
x x
x
N
E
T1
G2
WE
06 (D
egra
ded
Cor
e C
oolin
g) E
G2.
4.21
1.
Par
tial:
The
ste
m q
uest
ion
phra
se “i
s a
com
plet
e lis
t of a
ll...”
will
le
ad to
a n
o co
rrec
t ans
wer
pos
t-exa
m c
omm
ent.
Eve
n th
ough
th
e st
em q
uest
ion
says
“Bas
ed o
nly
on th
e co
nditi
ons
abov
e..”,
th
is d
oesn
’t pr
eclu
de a
n ap
plic
ant s
ucce
ssfu
lly c
onte
stin
g th
at
ther
e is
no
corr
ect a
nsw
er w
hen
taki
ng in
to a
ccou
nt o
ther
co
nditi
ons
that
wou
ld o
ccur
as
a re
sult
of th
e st
em c
ondi
tions
.
Sug
gest
re-w
ordi
ng th
e st
em q
uest
ion
as:
“WO
OTF
iden
tifie
s R
ED
or O
RA
NG
E C
ritic
al S
afet
y Fu
nctio
ns
for t
hese
con
ditio
ns?”
2.
Cue
: Th
e on
ly tr
ends
nec
essa
ry a
re th
e Tc
old
and
sour
ce
rang
e tre
nds;
the
othe
r tre
nds
in th
e 4th
, 5th, 6
th, a
nd 7
th b
ulle
ts
are
not n
eces
sary
to e
licit
the
corr
ect r
espo
nse.
3.
Ste
m F
ocus
: In
the
1st b
ulle
t, th
e ph
rase
“Los
s of
Coo
lant
A
ccid
ent”
is s
pelle
d ou
t eve
n th
ough
this
form
at is
not
use
d in
ot
her t
est i
tem
s lik
e Q
#3 a
nd Q
#4.
Nee
d to
be
cons
iste
nt
thou
gh o
ut th
e en
tire
exam
.
4.
Ste
m F
ocus
: Th
e st
em q
uest
ion
is m
issi
ng a
que
stio
n m
ark.
5.
4-19
-18:
Add
ed R
HR
flow
to e
nhan
ce In
tegr
ity p
laus
ibili
ty;
othe
r com
men
ts in
corp
orat
ed.
Que
stio
n is
SA
T.
Q
# 1.
LO
K
(F/H
)
2.
LOD
(1
-5)
3. P
sych
omet
ric F
law
s 4.
Job
Con
tent
Fla
ws
5. O
ther
6.
S
ourc
e B
/M/N
7.
Sta
tus
U/E
/S
8.
Exp
lana
tion
Ste
m
Focu
s C
ues
T/F
Cre
d.
Dis
t. P
artia
l Jo
b-Li
nk
Min
utia
#/
un
its
Bac
k-w
ard
Q=
K/A
S
RO
O
nly
25
x 2
x
x
x
N
E
/U
T1G
2 W
E08
(R
CS
Ove
rcoo
ling-
PTS
pro
cedu
res)
EK
3.2
1.
Cre
d D
ist:
Cho
ice
A is
not
pla
usib
le b
ecau
se it
is th
e on
ly
Cho
ice
with
out a
n ac
com
pany
ing
“rea
son.
”
2.
Cre
d D
ist:
Cho
ice
D (i
nitia
te S
I bec
ause
of P
ZR le
vel)
is n
ot
plau
sibl
e be
caus
e th
e st
em c
onta
ins
leve
l ind
icat
ions
muc
h lo
wer
, in
the
reac
tor v
esse
l hea
d.
3.
Par
tial:
To
ensu
re o
ne c
orre
ct a
nsw
er, t
he s
tem
que
stio
n an
d C
hoic
es n
eed
to b
e re
-wor
ded
to s
ay “r
equi
red”
inst
ead
of u
sing
th
e ph
rase
“will
be.
” Fo
r exa
mpl
e:
“WO
OTF
iden
tifie
s w
heth
er S
I is
requ
ired
to b
e re
initi
ated
in
acco
rdan
ce w
ith E
OP
-16.
0, in
clud
ing
the
reas
on?”
4.
Ste
m F
ocus
: Th
e 4th
and
5th b
ulle
ts m
ay n
eed
to b
e m
oved
up
afte
r the
2nd
bul
let t
o cl
arify
the
sequ
ence
of e
vent
s. W
as S
I te
rmin
ated
at E
OP
-16,
Ste
p 10
or e
arlie
r in
EO
P-1
.2, S
I Te
rmin
atio
n? W
ere
the
RC
Ps
stop
ped
in E
OP
-2.0
(E1)
?
Pro
vide
the
bulle
ts in
the
orde
r the
y w
ere
perfo
rmed
in th
e E
OP
ne
twor
k.
5.
Ste
m F
ocus
: Th
e 7th
bul
let p
hras
e “a
re p
rese
nt o
n th
e m
ain
cont
rol b
oard
” is
not n
eces
sary
; sug
gest
usi
ng th
e w
ord
“exi
st.”
6.
LOK
: Th
is q
uest
ion
may
be
high
er c
og; l
et’s
dis
cuss
.
7.
4-23
-18:
Rew
rote
que
stio
n; n
ew q
uest
ion
is S
AT.
Q
# 1.
LO
K
(F/H
)
2.
LOD
(1
-5)
3. P
sych
omet
ric F
law
s 4.
Job
Con
tent
Fla
ws
5. O
ther
6.
S
ourc
e B
/M/N
7.
Sta
tus
U/E
/S
8.
Exp
lana
tion
Ste
m
Focu
s C
ues
T/F
Cre
d.
Dis
t. P
artia
l Jo
b-Li
nk
Min
utia
#/
un
its
Bac
k-w
ard
Q=
K/A
S
RO
O
nly
26
F 2
x x
N
E
T1
G2
WE
15 (C
onta
inm
ent F
lood
ing)
EK
2.1
1.
Job-
Link
: Th
e se
cond
par
t of t
he te
st it
em te
sts
RO
app
lican
ts’
know
ledg
e of
the
EO
P b
ases
for E
OP
-17.
1 (F
R-Z
.2).
The
SR
O
Cla
rific
atio
n G
uida
nce
Doc
umen
t (E
S-4
01, A
ttach
men
t 2) i
s si
lent
on
whe
ther
EO
P b
ases
kno
wle
dge
is S
RO
or R
O
know
ledg
e. T
he le
arni
ng o
bjec
tive
(STA
TE th
e en
try c
ondi
tions
of
EO
P-1
2.0,
Sym
ptom
s, a
nd T
rans
ition
s fro
m o
ther
pr
oced
ures
) doe
s no
t jus
tify
test
ing
the
RO
app
lican
ts’
know
ledg
e of
the
EO
P b
ases
for E
OP
-17.
1; th
eref
ore,
this
test
ite
m is
vul
nera
ble
to a
pos
t-exa
m a
ppea
l. S
ugge
st te
stin
g a
requ
ired
man
ual o
pera
tor a
ctio
n in
EO
P-1
7.1,
or m
itiga
tive
stra
tegy
.
2.
The
refe
renc
e pr
ovid
ed to
the
appl
ican
ts is
not
nec
essa
ry s
ince
th
e pr
opos
ed te
st it
em is
real
ly a
skin
g w
hich
sum
p le
vel (
RB
or
RH
R) i
s us
ed to
iden
tify
an O
rang
e P
ath.
The
“ins
trum
enta
tion
set”
is n
ot n
eces
sary
; the
kno
wle
dge
bein
g te
sted
is th
at th
e R
HR
Sum
p le
vel i
s us
ed to
iden
tify
an O
rang
e P
ath.
3.
Par
tial:
Bec
ause
the
RH
R S
ump
Leve
ls (S
et B
) ind
icat
ions
on
the
prov
ided
refe
renc
e ar
e 41
7 fe
et, a
n ap
plic
ant c
an
succ
essf
ully
arg
ue th
ere
is n
o co
rrec
t ans
wer
sin
ce th
e O
rang
e P
ath
set p
oint
is 4
19.5
feet
.
4.
Ste
m F
ocus
: Th
e 1st
bul
let i
s no
t nec
essa
ry.
5.
Ste
m F
ocus
: Th
e st
em N
OTE
and
the
bold
ed R
EFE
RE
NC
E
PR
OV
IDE
D a
re re
dund
ant.
6.
Ste
m F
ocus
: Th
e st
em q
uest
ion
need
s a
ques
tion
mar
k.
7.
4-23
-18:
Que
stio
n re
plac
ed w
ith n
ew q
uest
ion
on S
W le
ak; O
L Fe
edba
ck It
em 4
01.5
5. Q
uest
ion
is S
AT.
Q
# 1.
LO
K
(F/H
)
2.
LOD
(1
-5)
3. P
sych
omet
ric F
law
s 4.
Job
Con
tent
Fla
ws
5. O
ther
6.
S
ourc
e B
/M/N
7.
Sta
tus
U/E
/S
8.
Exp
lana
tion
Ste
m
Focu
s C
ues
T/F
Cre
d.
Dis
t. P
artia
l Jo
b-Li
nk
Min
utia
#/
un
its
Bac
k-w
ard
Q=
K/A
S
RO
O
nly
27
H
2 x
x
x
M
E/U
T1
G2
WE
16 (H
igh
Con
tain
men
t Rad
iatio
n-re
med
ial a
ctio
ns) E
K1.
3
1.
Q=K
/A:
Alth
ough
the
1st fi
ll-in
-the-
blan
k st
atem
ent t
ests
the
porti
on o
f the
K/A
sta
tem
ent r
elat
ed to
“ann
unci
ator
s an
d co
nditi
on in
dica
ting
sign
als,
the
2nd fi
ll-in
-the-
blan
k st
atem
ent
does
not
test
rem
edia
l act
ions
ass
ocia
ted
with
EO
P-1
7.2
(E16
, FR
-Z.3
), R
espo
nse
to H
igh
Rea
ctor
Bui
ldin
g R
adia
tion.
Th
e E
FW fl
ow a
djus
tmen
t is
not r
elat
ed to
the
K/A
topi
c.
2.
Cue
: Th
e 6th
bul
let p
hras
e “a
nd in
crea
sing
” is
not n
eces
sary
to
elic
it th
e co
rrec
t res
pons
e. (
The
only
per
tinen
t inf
orm
atio
n is
12
00 R
/hr).
Add
ition
ally
, the
7th b
ulle
t phr
ase
“and
eng
inee
ring
is n
ot
eval
uatin
g in
tegr
ated
dos
e” is
not
nec
essa
ry to
elic
it th
e co
rrec
t re
spon
se.
(The
onl
y pe
rtine
nt in
form
atio
n is
IPC
S is
not
av
aila
ble.
)
3.
Ste
m F
ocus
: Th
e st
em q
uest
ion
asks
whi
ch c
hoic
e co
mpl
etes
B
OTH
sta
tem
ents
per
OA
P-1
03.4
, EO
P/A
OP
Use
r’s G
uide
, ev
en th
ough
the
2nd fi
ll-in
-the-
blan
k st
atem
ent h
as n
othi
ng to
do
with
OA
P-1
03.4
.
4.
4-19
-18:
Rem
edia
l act
ion
porti
on o
f K/A
is b
eing
hit
beca
use
the
requ
ired
actio
n de
pend
s on
usi
ng th
e ad
vers
e co
ntai
nmen
t ra
diat
ion
valu
e. Q
uest
ion
is S
AT.
Q
# 1.
LO
K
(F/H
)
2.
LOD
(1
-5)
3. P
sych
omet
ric F
law
s 4.
Job
Con
tent
Fla
ws
5. O
ther
6.
S
ourc
e B
/M/N
7.
Sta
tus
U/E
/S
8.
Exp
lana
tion
Ste
m
Focu
s C
ues
T/F
Cre
d.
Dis
t. P
artia
l Jo
b-Li
nk
Min
utia
#/
un
its
Bac
k-w
ard
Q=
K/A
S
RO
O
nly
28
H
2 x
x
x
N
U
T2G
1 (R
CP
-des
ign
feat
ure/
inte
rlock
col
d w
ater
or t
rans
ient
) K
4.02
1.
Cre
d D
ist:
The
1st p
art o
f Cho
ices
C/D
(ste
am d
umps
cau
se
pow
er to
rise
) is
not p
laus
ible
bec
ause
ste
am d
umps
act
uate
in
resp
onse
to R
CS
ove
r tem
pera
ture
, whi
ch is
neg
ativ
e re
activ
ity.
(See
Q#3
2) T
here
is n
othi
ng in
the
stem
that
cou
ld b
e m
isco
nstru
ed to
indi
cate
that
the
stea
m d
umps
wou
ldn’
t ope
rate
co
rrect
ly.
2.
Cue
: Th
e 4th
bul
let i
s no
t nec
essa
ry to
elic
it th
e co
rrec
t re
spon
se.
The
4th b
ulle
t is
Pow
er R
ange
Cha
nnel
s, a
nd th
e co
rrec
t Cho
ice
is a
lso
Pow
er R
ange
Cha
nnel
s.
3.
Cue
: Th
e 1st
fill-
in-th
e-bl
ank
phra
se “r
eact
ivity
inse
rted
by” i
s no
t nec
essa
ry to
elic
it th
e co
rrec
t res
pons
e.
4.
Ste
m F
ocus
: Th
e 2nd
bul
let i
s no
t nec
essa
ry.
5.
Are
ther
e an
y R
CP
des
ign
feat
ures
/inte
rlock
s th
at p
reve
nt
trans
ient
s? F
lyw
heel
and
Ant
i-Rot
atio
n D
evic
e?
6.
4-23
-18:
Rep
lace
d qu
estio
n w
ith n
ew q
uest
ion
to te
st R
CP
bus
sw
ap-o
ver i
nter
lock
; que
stio
n is
SA
T.
29
F 2
x
N
E
T2
G1
(CV
CS
-bor
atio
n/di
lutio
n ba
tch
cont
rol)
A4.
12
1.
We
need
to e
nsur
e th
is te
st it
em d
oesn
’t ov
erla
p a
sim
ulat
or
scen
ario
. Th
e 1st
fill-
in-th
e-bl
ank
stat
emen
t may
ove
rlap.
2.
Ste
m F
ocus
: Th
e 3rd
bul
let i
s no
t nec
essa
ry.
3.
Ste
m F
ocus
: Th
e 1st
fill-
in-th
e-bl
ank
stat
emen
t phr
ase
“With
out
oper
ator
act
ion”
is n
ot n
eces
sary
.
4.
4-19
-18:
To
avoi
d op
erat
ing
test
ove
rlap,
re-w
orke
d qu
estio
n to
te
st w
hen
man
ual m
akeu
p is
term
inat
ed.
Que
stio
n is
SA
T.
Q
# 1.
LO
K
(F/H
)
2.
LOD
(1
-5)
3. P
sych
omet
ric F
law
s 4.
Job
Con
tent
Fla
ws
5. O
ther
6.
S
ourc
e B
/M/N
7.
Sta
tus
U/E
/S
8.
Exp
lana
tion
Ste
m
Focu
s C
ues
T/F
Cre
d.
Dis
t. P
artia
l Jo
b-Li
nk
Min
utia
#/
un
its
Bac
k-w
ard
Q=
K/A
S
RO
O
nly
30
F 2
x
x
M
E
/U
T2G
1 (R
HR
-pre
ssur
e tra
nsie
nt d
urin
g co
ld s
hutd
own)
A2.
02
1.
Q=K
/A:
The
prop
osed
test
item
doe
s no
t req
uire
the
appl
ican
ts
to p
redi
ct th
e im
pact
of a
pre
ssur
e tra
nsie
nt d
urin
g co
ld
shut
dow
n. E
S-4
01, S
ectio
n D
.2.a
(pag
e 7
of 5
2) s
tate
s:
“Whe
n w
ritin
g qu
estio
ns fo
r cou
pled
K/A
s (e
.g.,
A2)
try
to te
st
both
asp
ects
of t
he K
/A s
tate
men
t.”
The
“pre
dict
” por
tion
of th
e K
/A c
an b
e ac
com
plis
hed
by te
stin
g th
e ap
plic
ants
’ kno
wle
dge
of w
here
the
suct
ion
relie
f val
ve fl
ow
is d
irect
ed.
The
1st fi
ll-in
-the-
blan
k st
atem
ent s
houl
d pr
obab
ly
rem
ain,
sin
ce th
ere
appe
ars
to b
e no
sub
stan
tive
guid
ance
in
AR
PA
XP
-610
, or a
n ab
norm
al p
roce
dure
, for
miti
gatin
g th
e ov
erpr
essu
re tr
ansi
ent.
2.
Ste
m F
ocus
: N
one
of th
e in
form
atio
n ab
ove
the
stem
que
stio
n is
nec
essa
ry.
3.
Ste
m F
ocus
: Th
e 2nd
fill-
in-th
e-bl
ank
phra
se “w
ill e
nsur
e th
at
T.S
. 3.4
.9.3
is m
et b
y” is
not
nec
essa
ry.
Sug
gest
re-w
ordi
ng a
s “G
OP
-6 re
quire
s op
enin
g a
min
imum
of _
__(2
)___
.”
4.
Add
the
plau
sibi
lity
for 2
00°F
(1st p
art o
f Cho
ices
A/B
) to
the
dist
ract
or a
naly
sis.
SO
P-1
15 s
tate
s th
at in
itiat
ing
a co
oldo
wn
on R
HR
whi
le R
CS
HL
tem
pera
ture
are
> 2
00 d
eg re
nder
s R
HR
in
capa
ble
of b
eing
alig
ned
to R
WS
T.
5.
4-23
-18:
Re-
wor
ked
ques
tion
to te
st w
here
wat
er m
oves
whe
n O
verp
ress
ure
Pro
tect
ion
relie
fs li
ft. Q
uest
ion
is S
AT.
Q
# 1.
LO
K
(F/H
)
2.
LOD
(1
-5)
3. P
sych
omet
ric F
law
s 4.
Job
Con
tent
Fla
ws
5. O
ther
6.
S
ourc
e B
/M/N
7.
Sta
tus
U/E
/S
8.
Exp
lana
tion
Ste
m
Focu
s C
ues
T/F
Cre
d.
Dis
t. P
artia
l Jo
b-Li
nk
Min
utia
#/
un
its
Bac
k-w
ard
Q=
K/A
S
RO
O
nly
31
H
2 x
x
x
x
N
E
T2G
1 (E
CC
S-e
ffect
of a
loss
of p
ump)
K6.
13
1.
Sin
ce th
e 2nd
par
t of e
ach
Cho
ice
is u
niqu
e, th
e 1st
par
t of t
he
ques
tion
is n
ot b
eing
test
ed.
2.
Par
tial a
nd/o
r #/u
nits
: Th
e te
rm “p
umpe
d flo
w” i
s sl
ang;
; th
eref
ore,
this
test
item
is v
ulne
rabl
e to
pos
t exa
m a
ppea
l.
Rep
lace
with
the
spec
ific
met
er u
sed
to id
entif
y S
I flo
w to
the
core
. Fo
r exa
mpl
e, d
oes
SI-X
YZ, S
I Inj
ectio
n, in
dica
te fl
ow a
t th
is ti
me?
3.
Ste
m F
ocus
: Th
e 2nd
que
stio
n do
es n
ot n
eed
to re
fer t
o “A
” Tr
ain
pum
p re
stor
atio
n”; t
he re
fere
nce
to “A
” in
the
2nd p
art o
f ea
ch C
hoic
e ca
n be
elim
inat
ed, a
nd th
e 2nd
que
stio
n ca
n be
:
“Wha
t is/
are
the
min
imum
pum
p(s)
nee
ded
to ra
ise
flow
on
SI-
XY
Z, S
I Inj
ectio
n?”
4.
Cue
: Th
e 4th
bul
let i
n th
e In
itial
Con
ditio
ns is
not
nec
essa
ry
beca
use
RC
S p
ress
ure
is a
lso
prov
ided
in th
e C
urre
nt
Con
ditio
ns (3
rd b
ulle
t).
5.
Ste
m F
ocus
: Th
e In
itial
Con
ditio
ns b
ulle
t seq
uenc
e sh
ould
in
clud
e “C
” Cha
rgin
g P
ump
tagg
ed o
ut o
f ser
vice
with
the
1st
bulle
t, or
mov
e it
unde
r the
1st b
ulle
t.
6.
Ste
m F
ocus
: Th
e w
ord
“hav
e” in
the
6th In
itial
Con
ditio
ns b
ulle
t is
not
nec
essa
ry.
7.
Ste
m F
ocus
: Th
e ph
rase
“The
NR
OA
TC re
ports
that
..” is
not
ne
cess
ary
in th
e 1st
Cur
rent
Con
ditio
ns b
ulle
t.
8.
Ste
m F
ocus
: Th
e 4th
Cur
rent
Con
ditio
ns b
ulle
t is
not n
eces
sary
.
9.
Par
tial:
The
“B” C
harg
ing
Pum
p re
mai
ns ru
nnin
g; th
eref
ore,
SI
flow
cou
ld e
xist
on
the
CR
SI I
njec
tion
Flow
Met
er.
Dis
cuss
.
10.
Q
# 1.
LO
K
(F/H
)
2.
LOD
(1
-5)
3. P
sych
omet
ric F
law
s 4.
Job
Con
tent
Fla
ws
5. O
ther
6.
S
ourc
e B
/M/N
7.
Sta
tus
U/E
/S
8.
Exp
lana
tion
Ste
m
Focu
s C
ues
T/F
Cre
d.
Dis
t. P
artia
l Jo
b-Li
nk
Min
utia
#/
un
its
Bac
k-w
ard
Q=
K/A
S
RO
O
nly
32
H
2 x
x
x
M
E
T2G
1 (P
ZR R
elie
f/Que
nch
Tank
- PZR
Ove
r-pr
essu
rizat
ion)
A2.
03
1.
Par
tial:
Cho
ice
C is
als
o co
rrec
t bec
ause
SO
P-1
01, S
ectio
n V
, R
CD
T/P
RT
Out
age
Ope
ratio
ns, i
s us
ed to
dra
in th
e P
RT.
Ste
p 1.
5 st
ates
that
prio
r to
adju
stin
g P
RT
leve
l, th
e P
RT
is to
be
vent
ed.
Ther
efor
e, C
hoic
e C
is a
lso
corr
ect.
2.
The
oper
atio
nal v
alid
ity o
f the
CR
S b
eing
con
cern
ed w
ith th
e P
RT
follo
win
g a
loss
of a
ll el
ectri
cal l
oad
is q
uest
iona
ble,
sin
ce
the
CR
S w
ould
be
in th
e E
OP
s. S
ugge
st d
elet
ing
the
2nd b
ulle
t an
d m
odify
ing
the
3rd b
ulle
t:
“Pre
ssur
izer
PO
RV
s lif
ted
durin
g a
trans
ient
.”
3.
Par
tial:
To
ensu
re o
nly
one
corr
ect a
nsw
er, s
ugge
st in
clud
ing
the
phra
se “m
inim
um re
quire
d ac
tions
” in
the
stem
que
stio
n.
4.
Par
tial:
Sin
ce th
e st
em q
uest
ion
does
n’t s
peci
fy a
tim
e in
terv
al
to c
lear
the
alar
m, t
here
may
be
no c
orre
ct a
nsw
er if
the
crew
on
ly c
oole
d th
e P
RT
in a
ccor
danc
e w
ith S
OP
-101
, Sec
tion
O,
sinc
e co
olin
g co
uld
also
low
er th
e le
vel o
ver a
long
per
iod
of
time.
SO
P-1
01 d
oesn
’t sp
ecify
wha
t act
ions
hav
e to
be
take
n.
5.
Cue
: Th
e bo
lded
und
erlin
ed s
ente
nce
(Ass
ume
that
am
bien
t he
at lo
ss w
ill n
ot o
ccur
) poi
nts
the
appl
ican
t to
actio
n (3
), w
hich
is
coo
ling
the
PR
T.
6.
Ste
m F
ocus
: Th
e ph
rase
“as
nece
ssar
y” in
the
6th b
ulle
t is
not
nece
ssar
y.
7.
4-19
-18:
Rew
rote
que
stio
n; n
ew q
uest
ion
is S
AT.
Q
# 1.
LO
K
(F/H
)
2.
LOD
(1
-5)
3. P
sych
omet
ric F
law
s 4.
Job
Con
tent
Fla
ws
5. O
ther
6.
S
ourc
e B
/M/N
7.
Sta
tus
U/E
/S
8.
Exp
lana
tion
Ste
m
Focu
s C
ues
T/F
Cre
d.
Dis
t. P
artia
l Jo
b-Li
nk
Min
utia
#/
un
its
Bac
k-w
ard
Q=
K/A
S
RO
O
nly
33
H
2 x
x
M
U
T2G
1 (P
ZR R
elie
f/Que
nch
Tank
-rel
atio
nshi
p to
Cnm
t) K
1.01
1.
Cre
d D
ist:
The
2nd
par
t of C
hoic
es B
/D (P
RT
rupt
ure
diap
hrag
m
caus
es A
dver
se C
nmt R
ad) i
s no
t pla
usib
le b
ecau
se:
th
ere
is n
othi
ng in
the
stem
that
cou
ld b
e m
isco
nstru
ed a
s fu
el fa
ilure
,
th
e 2n
d fil
l-in-
the-
blan
k st
atem
ent s
ays
“as
a re
sult
of th
is
relie
f”, w
here
“rel
ief”
mea
ns o
ver-
pres
sure
,
th
e 2nd
bul
let i
n th
e st
em s
ays
that
RB
Spr
ay P
umps
are
in
op -
- mea
ning
RB
Pre
ssur
e is
unc
ontro
lled,
and
th
e 1st
fill-
in-th
e-bl
ank
stat
emen
t is
abou
t the
rupt
ure
diap
hrag
m, w
hich
impl
ies
an im
pact
on
RB
Pre
ssur
e.
Sug
gest
kee
ping
the
1st p
art o
f the
que
stio
n an
d re
visi
ng th
e 2nd
pa
rt of
the
ques
tion
to te
st a
phy
sica
l rel
atio
nshi
p w
ith
cont
ainm
ent,
such
as
PR
T lo
catio
n, e
tc.
2.
Ste
m F
ocus
: Th
e bo
lded
und
erlin
ed s
ente
nce
shou
ld b
e in
clud
ed in
the
3rd s
tem
bul
let a
s a
plan
t con
ditio
n in
stea
d of
an
assu
mpt
ion.
3.
Ste
m F
ocus
: Th
e 5th
bul
let i
s no
t nec
essa
ry.
4.
Ste
m F
ocus
: Th
e w
ord
“dev
ice”
in th
e 1st
fill-
in-th
e-bl
ank
stat
emen
t sho
uld
be “r
uptu
re d
iaph
ragm
.”
5.
Ste
m F
ocus
: Th
e 2nd
fill-
in-th
e-bl
ank
stat
emen
t has
a ty
po, “
will
be
firs
t be
used
.”
Q
# 1.
LO
K
(F/H
)
2.
LOD
(1
-5)
3. P
sych
omet
ric F
law
s 4.
Job
Con
tent
Fla
ws
5. O
ther
6.
S
ourc
e B
/M/N
7.
Sta
tus
U/E
/S
8.
Exp
lana
tion
Ste
m
Focu
s C
ues
T/F
Cre
d.
Dis
t. P
artia
l Jo
b-Li
nk
Min
utia
#/
un
its
Bac
k-w
ard
Q=
K/A
S
RO
O
nly
34
F 2
x
x
N
U
E
T2G
1 (C
CW
-phy
sica
l con
nect
ions
/rela
tions
hip
w/ S
WS
) K
1.01
1.
Cre
d D
ist:
The
2nd
par
t of C
hoic
es A
/C (o
ut-o
f-ser
vice
SW
trai
n av
aila
ble
w/o
man
ual v
alve
re-a
lignm
ent)
is n
ot p
laus
ible
be
caus
e th
e S
W lo
ops
are
inde
pend
ent,
and
the
pum
p au
to-
star
t fea
ture
is n
ot u
sed.
The
pla
usib
ility
exa
mpl
es o
f EFW
and
R
HR
use
d in
the
dist
ract
er a
naly
sis
are
not s
imila
r bec
ause
thei
r cr
oss
tie is
with
in e
ach
syst
em, n
ot a
cros
s sy
stem
s. T
hese
C
hoic
es a
re a
lso
not p
laus
ible
bec
ause
they
con
tain
the
phra
se
“with
out a
dditi
onal
ope
rato
r act
ion
requ
ired”
, whi
ch is
rare
ly th
e ca
se a
fter a
Ser
vice
Wat
er P
ump
has
tripp
ed.
2.
Ste
m F
ocus
: Th
e w
ord
“up”
and
“dow
n” m
ay b
e sl
ang;
pro
vide
ex
ampl
es in
pro
cedu
res
whe
re th
ese
wor
ds a
re u
sed
to
repr
esen
t “ra
cked
in” a
nd “r
acke
d ou
t.”
3.
Ste
m F
ocus
: Th
e 2nd
fill-
in-th
e-bl
ank
stat
emen
t sho
uld
star
t with
th
e w
ord
“The
” ins
tead
of “
A.”
4.
4-19
-18:
Com
men
t #1
is N
/A b
ecau
se “B
” CC
W tr
ain
is a
ctiv
e lo
op.
Nor
mal
line
up is
2 S
W P
umps
runn
ing.
The
re is
a x
-tie
with
in e
ach
syst
em.
Que
stio
n is
SA
T.
Q
# 1.
LO
K
(F/H
)
2.
LOD
(1
-5)
3. P
sych
omet
ric F
law
s 4.
Job
Con
tent
Fla
ws
5. O
ther
6.
S
ourc
e B
/M/N
7.
Sta
tus
U/E
/S
8.
Exp
lana
tion
Ste
m
Focu
s C
ues
T/F
Cre
d.
Dis
t. P
artia
l Jo
b-Li
nk
Min
utia
#/
un
its
Bac
k-w
ard
Q=
K/A
S
RO
O
nly
35
H
2 x
x
X
B
E
T2G
1 0
10 (P
ZR P
ress
ure
Ctl-
loss
of p
ress
ure
dete
ctio
n) K
6.01
1.
Cue
: Th
e 1st
fill-
in-th
e-bl
ank
stat
emen
t phr
ase
“Mas
ter P
ress
ure
Con
trolle
r will
dem
and
the”
is n
ot n
eces
sary
to e
licit
the
corr
ect
resp
onse
. S
ugge
st:
“Imm
edia
tely
afte
r the
PT-
444
failu
re, t
he s
pray
val
ves
will
be
__(1
)__
.”
2.
Cue
: Th
e ph
rase
“as
inte
gral
act
ion
take
s ef
fect
” is
not
nece
ssar
y to
elic
it th
e co
rrec
t res
pons
e.
3.
Cue
: Th
is q
uest
ion
prov
ides
a c
ue to
the
appl
ican
ts fo
r Q#5
9,
that
the
Mas
ter P
ress
ure
Con
trolle
r is
rela
ted
to P
CV
-444
B.
4.
Ste
m F
ocus
: Th
e 1st
par
t of C
hoic
e D
sho
uld
mat
ch th
e w
ordi
ng
of th
e 1st
par
t of C
hoic
e A
, tha
t is,
Cho
ice
D s
houl
d sa
y “fu
lly
open
” ins
tead
of “
100%
ope
n.”
5.
The
ques
tion
is li
sted
as
MO
DIF
IED
; how
ever
, the
ste
m is
ex
actly
the
sam
e as
PZR
PR
ES
SC
NTR
LSYS
68.
ES
-401
, S
ectio
n D
.2.f
(pag
e 9
of 5
2) s
tate
s:
“…bu
t sig
nific
antly
mod
ify e
ach
ques
tion
by c
hang
ing
at le
ast
one
perti
nent
con
ditio
n in
the
stem
and
at l
east
one
dis
tract
or.”
6.
4-19
-18:
Cha
nged
to B
ank
ques
tion
desi
gnat
or.
Com
men
ts
inco
rpor
ated
; que
stio
n is
SA
T.
Q
# 1.
LO
K
(F/H
)
2.
LOD
(1
-5)
3. P
sych
omet
ric F
law
s 4.
Job
Con
tent
Fla
ws
5. O
ther
6.
S
ourc
e B
/M/N
7.
Sta
tus
U/E
/S
8.
Exp
lana
tion
Ste
m
Focu
s C
ues
T/F
Cre
d.
Dis
t. P
artia
l Jo
b-Li
nk
Min
utia
#/
un
its
Bac
k-w
ard
Q=
K/A
S
RO
O
nly
36
H
1.9
x
M
E
T2
G1
012
(RP
S-D
NB
) K
5.01
1.
LOD
: Th
e pr
opos
ed te
st it
em d
oesn
’t te
st p
lant
-spe
cific
in
form
atio
n; th
e pr
opos
ed te
st it
em s
olel
y te
sts
gene
ric
fund
amen
tals
K/A
193
008,
The
rmal
Hyd
raul
ics,
K1.
05:
List
par
amet
ers
that
affe
ct D
NR
and
DN
BR
and
des
crib
e th
eir
affe
cts.
Her
e is
the
logi
c th
at c
an b
e us
ed to
ded
uce
the
corr
ect a
nsw
er
with
out k
now
ing
any
plan
t-spe
cific
info
rmat
ion:
Whe
n a
spra
y va
lve
is o
pene
d, th
e pr
essu
re g
oes
dow
n, a
nd th
e sy
stem
bec
omes
clo
ser t
o sa
tura
tion
(DN
B).
Sin
ce th
e 2nd
fill-
in-
the-
blan
k st
atem
ent a
lread
y te
lls th
e ap
plic
ants
that
the
set p
oint
w
ill c
hang
e, th
en th
e an
swer
can
be
dedu
ced
by k
now
ing
that
, si
nce
the
syst
em is
clo
ser t
o D
NB
, the
n th
e re
acto
r pro
tect
ion
set p
oint
mus
t bec
ome
mor
e co
nser
vativ
e, i.
e., t
rip th
e re
acto
r at
a po
int m
uch
low
er th
an th
e or
igin
al 1
23%
trip
set
poi
nt.
Sug
gest
test
ing
wha
t the
OT∆
T se
t poi
nt v
alue
is a
t 100
%
pow
er a
nd th
en h
ow th
e se
t poi
nt is
affe
cted
if a
spr
ay v
alve
in
adve
rtent
ly o
pene
d.
2.
Wha
t is
the
oper
atio
nal v
alid
ity o
f an
oper
ator
ope
ning
the
spra
y va
lve
at 1
00%
pow
er?
3.
Ste
m F
ocus
: Th
e tw
o bo
lded
and
und
erlin
ed s
tate
men
ts a
re
not n
eces
sary
.
4.
Ste
m F
ocus
: Th
e 1st
fill-
in-th
e-bl
ank
stat
emen
t phr
ase
“Ope
ning
PC
V-4
44D
at 1
00%
pow
er c
ause
s” is
not
nec
essa
ry.
5.
Ste
m F
ocus
: Th
e la
st w
ord
in th
e st
em q
uest
ion
shou
ld b
e pl
ural
, tha
t is,
sta
tem
ents
inst
ead
of “s
tate
men
t.”
37
F 2
B
U
T2
G1
012
(RP
S-lo
ss o
f trip
logi
c ci
rcui
t) K
6.03
1.
Q=K
/A:
The
prop
osed
test
item
doe
sn’t
test
the
appl
ican
ts’
know
ledg
e of
how
the
loss
of a
trip
circ
uit a
ffect
s R
PS
.
The
1st fi
ll-in
-the-
blan
k st
atem
ent t
ests
“req
uire
d to
ope
rate
pr
oper
ly” a
nd th
e 2nd
fill-
in-th
e-bl
ank
stat
emen
t tes
ts “n
orm
al s
et
poin
t.” N
eith
er p
art o
f the
test
item
test
s ho
w th
e lo
ss o
f a R
PS
tri
p ci
rcui
t affe
cts
the
RP
S.
Sug
gest
test
ing
how
the
loss
of a
per
mis
sive
circ
uit,
or a
tra
nsm
itter
, will
affe
ct R
PS
, sim
ilar t
o th
e or
igin
al v
ersi
on o
f the
qu
estio
n.
Q
# 1.
LO
K
(F/H
)
2.
LOD
(1
-5)
3. P
sych
omet
ric F
law
s 4.
Job
Con
tent
Fla
ws
5. O
ther
6.
S
ourc
e B
/M/N
7.
Sta
tus
U/E
/S
8.
Exp
lana
tion
Ste
m
Focu
s C
ues
T/F
Cre
d.
Dis
t. P
artia
l Jo
b-Li
nk
Min
utia
#/
un
its
Bac
k-w
ard
Q=
K/A
S
RO
O
nly
38
H
2 x
x
M
E
T2G
1 0
13 (E
SFA
S-a
nnun
ciat
ors,
ala
rms,
or p
roce
dure
s) G
2.4.
31
1.
Par
tial:
Bas
ed o
n th
e 2nd
ste
m b
ulle
t (S
I spu
rious
ly a
ctua
ted)
, an
app
lican
t can
suc
cess
fully
arg
ue th
at th
ere
are
no c
orre
ct
answ
ers,
sin
ce th
e S
I log
ic o
bvio
usly
isn’
t wor
king
cor
rect
ly.
IF
Cho
ice
C (O
nly
one
train
of S
I res
et) i
s th
e co
rrec
t ans
wer
, the
n th
e st
ate
of th
e S
I log
ic b
ecom
es q
uest
iona
ble
to th
e po
int t
hat
ther
e is
no
way
to p
redi
ct th
e an
swer
of t
he 1
st a
nd 2
nd s
tem
qu
estio
ns.
2.
IF a
ny o
f the
sce
nario
s in
volv
e re
setti
ng S
I, TH
EN
this
test
item
ov
erla
ps th
e sa
me
know
ledg
e in
the
oper
atin
g ex
am.
3.
Ste
m F
ocus
: Th
e tw
o lig
hts
for S
I AC
T an
d S
I BLC
K h
ave
diffe
rent
sta
tes
of b
right
ness
; it i
s no
t pos
sibl
e to
use
the
pict
ure
to d
eter
min
e th
e st
ate
of b
right
ness
. S
ugge
st in
clud
ing
two
mor
e bu
llets
in th
e st
em th
at s
tate
whi
ch li
ghts
are
illu
min
ated
, si
mila
r to
the
orig
inal
ver
sion
of t
his
test
item
.
4.
4-19
-18:
Non
e of
sce
nario
s ha
ve fa
ilure
of o
ne tr
ain
to re
set.
O
ther
com
men
ts in
corp
orat
ed; q
uest
ion
is S
AT.
Q
# 1.
LO
K
(F/H
)
2.
LOD
(1
-5)
3. P
sych
omet
ric F
law
s 4.
Job
Con
tent
Fla
ws
5. O
ther
6.
S
ourc
e B
/M/N
7.
Sta
tus
U/E
/S
8.
Exp
lana
tion
Ste
m
Focu
s C
ues
T/F
Cre
d.
Dis
t. P
artia
l Jo
b-Li
nk
Min
utia
#/
un
its
Bac
k-w
ard
Q=
K/A
S
RO
O
nly
39
H
2 x
x
x
B
E
T2G
1 0
13 (
ES
FAS
-vita
l pow
er lo
ad c
ontro
l) K
4.11
1.
Par
tial:
Eac
h an
swer
cho
ice
shou
ld s
tand
on
its o
wn,
with
out
requ
iring
the
appl
ican
t to
com
pare
one
ans
wer
cho
ice
to
anot
her.
Tec
hnic
ally
, Cho
ice
A is
not
ent
irely
cor
rect
sin
ce o
ther
pl
ant a
ctio
ns (b
eyon
d th
e sc
ope
of th
is q
uest
ion)
are
requ
ired
to
be ta
ken.
How
ever
, sin
ce C
hoic
e A
use
s th
e w
ord
“Onl
y”, a
n ap
plic
ant c
an s
ucce
ssfu
lly c
onte
nd th
at th
ere
is n
o ab
solu
te
corr
ect a
nsw
er, b
ut in
stea
d, o
ne a
nsw
er th
at is
“bet
ter”
than
the
othe
rs.
2.
Ste
m F
ocus
: The
1st p
art o
f the
que
stio
n is
real
ly o
nly
aski
ng
whe
ther
the
cont
rol g
roup
hea
ters
will
/will
Not
be
used
; the
2nd
pa
rt of
the
ques
tion
is re
ally
onl
y as
king
whe
ther
the
ES
F LO
AD
ING
SE
Q A
/B R
ES
ETS
Sw
itch
is/is
Not
requ
ired
to b
e ta
ken
to th
e A
UTO
-STA
RT
BLO
CK
S p
ositi
on.
Sug
gest
re-w
orki
ng th
e st
em q
uest
ions
to te
st th
ese
aspe
cts,
in
stea
d of
incl
udin
g th
e B
acku
p G
roup
hea
ters
and
the
NO
N-
ES
F LC
KO
UTS
item
s, s
ince
thes
e ite
ms
are
cont
aine
d in
eve
ry
Cho
ice.
3.
#/un
its:
The
2nd p
art o
f the
que
stio
n is
not
spe
cific
as
to
switc
hes.
For
exa
mpl
e, th
e 2nd
par
t of C
hoic
e A
sho
uld
be
wor
ded
as:
ES
F LO
AD
ING
SE
Q A
/B R
ES
ETS
sw
itch
mus
t be
take
n to
the
NO
N-E
SF
LCK
OU
TS p
ositi
on.
4.
4-19
-18:
Com
men
t #1
is N
/A; o
ther
com
men
ts in
corp
orat
ed.
Que
stio
n is
SA
T.
40
H
2 x
x
N
E
T2G
1 0
22 (C
onta
inm
ent C
oolin
g-K
now
ledg
e of
LC
Os)
G2.
2.22
1.
Job-
Link
: To
ens
ure
that
eve
ryon
e kn
ows
the
test
item
is o
nly
test
ing
abov
e-th
e-lin
e in
form
atio
n, s
ugge
st re
-wor
ding
the
2nd
stem
que
stio
n as
:
“Is T
.S. L
CO
3.6
.2.3
met
for t
he c
urre
nt c
ondi
tions
?”
2.
4-18
-18:
Com
men
t inc
orpo
rate
d; q
uest
ion
is S
AT.
Q
# 1.
LO
K
(F/H
)
2.
LOD
(1
-5)
3. P
sych
omet
ric F
law
s 4.
Job
Con
tent
Fla
ws
5. O
ther
6.
S
ourc
e B
/M/N
7.
Sta
tus
U/E
/S
8.
Exp
lana
tion
Ste
m
Focu
s C
ues
T/F
Cre
d.
Dis
t. P
artia
l Jo
b-Li
nk
Min
utia
#/
un
its
Bac
k-w
ard
Q=
K/A
S
RO
O
nly
41
H
2 x
x
x
N
E
026
(Con
tain
men
t Spr
ay –
con
tain
men
t sum
p le
vel)
A1.
03
1.
Par
tial:
Cho
ice
A (s
pray
sys
tem
CA
N p
erfo
rm it
s de
sign
fu
nctio
n) is
als
o co
rrec
t bec
ause
EO
P-2
.4 (E
CA
-1.1
) Ste
p 9
(Det
erm
ine
RB
Spr
ay P
ump
Req
uire
men
ts) a
llow
s th
e sp
ray
pum
ps to
be
oper
ated
, dep
endi
ng o
n co
ntai
nmen
t pre
ssur
e,
with
RW
ST
leve
l bet
wee
n 10
– 1
8%.
An
appl
ican
t can
su
cces
sful
ly a
rgue
that
EO
P-2
.4, S
tep
9 m
eets
the
defin
ition
of
“cap
able
of p
erfo
rmin
g its
des
ign
func
tion.
”
2.
Job-
Link
: IF
kno
wle
dge
of F
SA
R C
hapt
er 6
des
ign
basi
s in
form
atio
n is
requ
ired,
TH
EN
this
test
item
goe
s be
yond
RO
kn
owle
dge.
3.
Par
tial:
Cho
ice
D (s
pray
sys
tem
CA
NN
OT
perfo
rm it
s de
sign
fu
nctio
n –
pum
ps m
ust b
e st
oppe
d) is
als
o co
rrec
t bec
ause
the
stem
doe
s no
t inc
lude
con
tain
men
t pre
ssur
e, w
hich
is u
sed
in
EO
P-2
.4, S
tep
9 to
det
erm
ine
whe
ther
spr
ay p
ump
oper
atio
n is
/is n
ot a
llow
ed.
Eve
n th
ough
Cho
ice
D s
ays
“pum
ps m
ust b
e st
oppe
d fro
m a
loss
of R
WC
T su
ctio
n”, t
he a
pplic
ant c
an
succ
essf
ully
arg
ue th
at th
is is
an
IND
IRE
CT
issu
e af
ter s
wap
ov
er o
ccur
red.
4.
Ste
m F
ocus
: Th
e st
em q
uest
ion
phra
se “c
apab
le o
f per
form
ing
its d
esig
n fu
nctio
n” is
vag
ue; s
ugge
st re
-wor
king
the
ques
tion
to
test
whe
ther
RB
Spr
ay P
ump
oper
atio
n is
/ is
NO
T re
quire
d.
5.
Ste
m F
ocus
: Th
e 2nd
par
t of C
hoic
e A
sho
uld
be m
ore
clea
rly
wor
ded
as:
“suc
tion
valv
es h
ave
auto
-alig
ned
to th
e su
mp.
”
6.
Ste
m F
ocus
: Th
e 2nd
par
t of C
hoic
e B
sho
uld
be m
ore
clea
rly
wor
ded
as:
“the
RW
ST
rem
ains
the
suct
ion
sour
ce.”
7.
Ste
m F
ocus
: Th
e w
ord
“rea
ding
” in
the
3rd b
ulle
t sho
uld
be
“impl
emen
ting.
”
8.
Ste
m F
ocus
: To
be
cons
iste
nt w
ith th
e re
mai
nder
of t
he e
xam
, su
gges
t und
erlin
ing
and
bold
ing
the
wor
d cu
rren
t in
the
stem
qu
estio
n.
9.
Ens
ure
no o
verla
p w
ith S
RO
Q#8
3, a
nd R
O Q
#17.
10.
4-23
-18:
Com
men
ts in
corp
orat
ed; q
uest
ion
is S
AT.
Q
# 1.
LO
K
(F/H
)
2.
LOD
(1
-5)
3. P
sych
omet
ric F
law
s 4.
Job
Con
tent
Fla
ws
5. O
ther
6.
S
ourc
e B
/M/N
7.
Sta
tus
U/E
/S
8.
Exp
lana
tion
Ste
m
Focu
s C
ues
T/F
Cre
d.
Dis
t. P
artia
l Jo
b-Li
nk
Min
utia
#/
un
its
Bac
k-w
ard
Q=
K/A
S
RO
O
nly
42
x 2
M
E
02
6 (C
onta
inm
ent S
pray
-Pum
p st
arts
& M
OV
pos
ition
ing)
A3.
01
1.
The
2nd p
art o
f the
test
item
(set
poi
nt fo
r RB
Spr
ay P
ump
auto
-st
art)
over
laps
with
the
scen
ario
s; th
e ap
plic
ants
will
ver
ify th
e R
B S
pray
Pum
p au
to-s
tarts
at 1
2.05
psi
g du
ring
the
scen
ario
s.
Rep
lace
the
2nd p
art o
f the
test
item
.
2.
LOK
: D
iscu
ss w
heth
er th
is te
st it
em is
low
er c
og v
s hi
gh c
og.
43
H
2 x
x
N
U
039
(Mai
n &
Reh
eat S
team
-mon
itor a
uto-
isol
atio
n of
MR
SS
) A
3.02
1.
Cre
d D
ist:
Cho
ice
A (v
alve
pos
ition
s al
l cor
rect
) is
not p
laus
ible
be
caus
e th
ere
is a
diff
eren
ce b
etw
een
the
MS
Isol
atio
n V
alve
an
d th
e M
S Is
olat
ion
Byp
ass
Val
ve p
ositi
ons;
the
mai
n st
eam
sy
stem
wou
ld n
ever
be
desi
gned
in a
n un
safe
way
that
co
ntin
ued
to a
llow
ste
am fl
ow th
roug
h th
e br
eak
via
the
open
M
S Is
olat
ion
Byp
ass
Val
ve.
2.
Cre
d D
ist:
Cho
ice
B (M
S Is
olat
ion
shou
ld b
e op
en) i
s no
t pl
ausi
ble
beca
use
a M
SLB
has
occ
urre
d an
d th
e sy
stem
wou
ld
neve
r be
desi
gned
in a
n un
safe
way
that
the
isol
atio
n va
lve
rem
aine
d op
en.
3.
Ste
m F
ocus
: Th
e 1st
053
1 bu
llet s
houl
d be
cle
arly
wor
ded
as:
“A m
ain
stea
m li
ne b
reak
insi
de th
e R
B h
as o
ccur
red.
”
4.
Ste
m F
ocus
: Th
e w
ord
“cor
rect
ly” i
n th
e st
em q
uest
ion
is n
ot
nece
ssar
y. A
lso,
the
wor
d “p
rope
r” s
houl
d be
“req
uire
d.”
5.
4-23
-18:
Com
men
ts in
corp
orat
ed; q
uest
ion
is S
AT.
Q
# 1.
LO
K
(F/H
)
2.
LOD
(1
-5)
3. P
sych
omet
ric F
law
s 4.
Job
Con
tent
Fla
ws
5. O
ther
6.
S
ourc
e B
/M/N
7.
Sta
tus
U/E
/S
8.
Exp
lana
tion
Ste
m
Focu
s C
ues
T/F
Cre
d.
Dis
t. P
artia
l Jo
b-Li
nk
Min
utia
#/
un
its
Bac
k-w
ard
Q=
K/A
S
RO
O
nly
44
H
2 x
x
N
E
T2G
1 03
9 (M
ain
& R
ehea
t Ste
am-m
alfu
nctio
n ef
fect
on
RC
S)
K3.
05
1.
Cre
d D
ist:
Cho
ice
C a
ssum
es th
at th
e ap
plic
ant m
ade
the
corr
ect d
eter
min
atio
n th
at th
e st
eam
dum
ps h
ave
all o
pene
d.
Giv
en th
at c
orre
ct d
eter
min
atio
n, th
e la
st h
alf o
f the
2nd
par
t of
Cho
ice
C (g
reat
er th
an th
e ra
te o
f sec
onda
ry h
eat r
emov
al) i
s no
t pla
usib
le.
Sug
gest
cha
ngin
g th
e 2nd
par
t of C
hoic
e C
to
“pow
er ri
ses
to 1
0%.”
2.
Ste
m F
ocus
: Th
e 2nd
par
t of C
hoic
e A
sho
uld
not i
nter
fere
with
th
e pl
ausi
bilit
y of
the
2nd p
art o
f Cho
ice
B.
Sug
gest
re-w
ordi
ng
the
2nd p
art o
f Cho
ice
A a
s:
“ste
am g
ener
ator
PO
RV
s op
en; s
afet
y re
lief v
alve
s re
mai
n cl
osed
.”
3.
Ste
m F
ocus
: B
ased
on
Com
men
t #2,
sug
gest
re-w
ordi
ng th
e 2nd
par
t of C
hoic
e B
as:
“bot
h st
eam
gen
erat
or P
OR
Vs
and
the
safe
ty re
lief v
alve
(s) w
ith
the
low
est s
et p
oint
all
open
.”
4.
Ste
m F
ocus
: Th
e 3rd
Initi
al C
ondi
tion
bulle
t sho
uld
also
spe
cify
th
at th
e re
acto
r is
at th
e P
OA
H.
Alte
rnat
ivel
y, p
rovi
de s
tem
bu
llets
that
indi
cate
the
reac
tor i
s at
the
PO
AH
, suc
h as
PZR
le
vel r
isin
g, S
UR
dec
reas
ing,
etc
.
5.
Ste
m F
ocus
: Th
e ph
rase
“as
a re
sult
of th
e fa
ilure
” in
the
fill-o
n-th
e-bl
ank
stat
emen
t is
not n
eces
sary
.
6.
Ste
m F
ocus
: Th
e ph
rase
“and
pla
nt” i
n th
e 1st
bul
let i
s no
t ne
cess
ary.
7.
4-25
-18:
Com
men
t #4
is N
/A b
ecau
se p
ump
heat
can
cau
se
Tavg
to ri
se.
Com
men
ts in
corp
orat
ed; q
uest
ion
is S
AT.
Q
# 1.
LO
K
(F/H
)
2.
LOD
(1
-5)
3. P
sych
omet
ric F
law
s 4.
Job
Con
tent
Fla
ws
5. O
ther
6.
S
ourc
e B
/M/N
7.
Sta
tus
U/E
/S
8.
Exp
lana
tion
Ste
m
Focu
s C
ues
T/F
Cre
d.
Dis
t. P
artia
l Jo
b-Li
nk
Min
utia
#/
un
its
Bac
k-w
ard
Q=
K/A
S
RO
O
nly
45
F 2
x
x
x
B
U
T2
G1
059
(MFW
-con
nect
ions
/rela
tions
hip
w S
G)
K1.
03
1.
Cre
d D
ist:
Cho
ice
B (M
T be
arin
g oi
l tra
nsm
itter
s fa
il to
3 p
sig)
is
not p
laus
ible
for t
wo
reas
ons:
A
ll be
arin
g oi
l tra
nsm
itter
s fa
iling
to e
xact
ly 3
psi
g is
not
op
erat
iona
lly v
alid
; Cho
ice
B is
wor
ded
to im
ply
that
eve
ry
bear
ing
oil t
rans
mitt
er fa
ils to
3 p
sig.
The
re a
re ty
pica
lly 1
0 or
so
bear
ings
, eac
h w
ith a
n oi
l tra
nsm
itter
.
Th
ere
is n
o M
FW P
ump
“mai
n-tu
rbin
e-tri
p” fe
atur
e.
2.
C
red
Dis
t: C
hoic
e D
(MFW
Pum
ps tr
ip o
nly
afte
r nor
mal
RC
S
pres
sure
is re
ache
d) is
not
pla
usib
le b
ecau
se it
s w
ordi
ng im
plie
s th
at th
e M
FW P
umps
don
’t tri
p un
til a
fter R
CS
pre
ssur
e is
re
stor
ed to
223
5 ps
ig.
3.
Par
tial:
The
re is
no
initi
al p
lant
pow
er le
vel p
rovi
ded;
ther
efor
e,
ther
e m
ay b
e no
cor
rect
ans
wer
whe
n th
e pl
ant i
s in
itial
ly
shut
dow
n.
4.
Ste
m F
ocus
: Th
e ph
rase
“and
sta
biliz
es” i
n C
hoic
e A
is n
ot
nece
ssar
y.
5.
4-20
-18:
Com
men
ts in
corp
orat
ed; q
uest
ion
is S
AT.
Q
# 1.
LO
K
(F/H
)
2.
LOD
(1
-5)
3. P
sych
omet
ric F
law
s 4.
Job
Con
tent
Fla
ws
5. O
ther
6.
S
ourc
e B
/M/N
7.
Sta
tus
U/E
/S
8.
Exp
lana
tion
Ste
m
Focu
s C
ues
T/F
Cre
d.
Dis
t. P
artia
l Jo
b-Li
nk
Min
utia
#/
un
its
Bac
k-w
ard
Q=
K/A
S
RO
O
nly
46
F 2
x x
x
N
U
T2
G1
061
(EFW
-impl
icat
ion
of fe
ed li
ne v
oidi
ng)
K5.
05
1.
Cre
d D
ist:
The
2nd
par
t of C
hoic
es A
/C (c
once
rn is
dis
char
ge
line
chec
k va
lve
leak
age
caus
es p
ump
seal
dam
age)
is n
ot
plau
sibl
e be
caus
e al
l thr
ee E
FW p
umps
hav
e a
disc
harg
e ch
eck
valv
e. T
he tr
aini
ng m
ater
ials
do
not m
entio
n pu
mp
seal
s, o
r in
clud
e le
arni
ng o
bjec
tives
for t
he p
ump
seal
s.
Sug
gest
cha
ngin
g th
e 2nd
par
t of C
hoic
es A
/C fo
r the
con
cern
to
be th
e Te
rry
Turb
ine
Rup
ture
Dis
c (b
y m
odify
ing
the
stem
to
only
ask
abo
ut th
e TD
EFW
Pum
p), O
R c
hang
e so
the
conc
ern
is T
.S. 3
.7.9
, EFW
Pum
p A
rea
Tem
pera
ture
Mon
itorin
g, L
CO
lim
its.
2.
Cue
: Th
e fir
st q
uest
ion
phra
se “p
oten
tial f
or c
heck
val
ve
leak
age
from
the
stea
m g
ener
ator
s ba
ck to
the
EFW
sys
tem
” is
not n
eces
sary
to e
licit
the
corr
ect r
espo
nse.
3.
Cue
: Th
e se
cond
que
stio
n ph
rase
“if t
his
leak
age
is o
ccur
ring”
is
not
nec
essa
ry to
elic
it th
e co
rrec
t res
pons
e.
4.
Ste
m F
ocus
: Th
e 1st
par
t of C
hoic
es C
/D s
houl
d m
irror
the
1st
part
of C
hoic
es A
/B; t
he 1
st p
art o
f Cho
ices
C/D
sho
uld
not
cont
ain
the
reas
on.
For e
xam
ple,
sug
gest
cha
ngin
g th
e 1st
par
t of
Cho
ices
C/D
to b
e:
“EFW
Pum
p D
isch
arge
line
s ar
e m
anua
lly v
ente
d.”
5.
Ste
m F
ocus
: S
ugge
st c
hang
ing
the
last
wor
d in
the
1st p
art o
f C
hoic
es A
/B to
be
“rec
orde
d”, i
nste
ad o
f “m
onito
red.
”
6.
4-20
-18:
Com
men
ts in
corp
orat
ed; q
uest
ion
is S
AT.
Q
# 1.
LO
K
(F/H
)
2.
LOD
(1
-5)
3. P
sych
omet
ric F
law
s 4.
Job
Con
tent
Fla
ws
5. O
ther
6.
S
ourc
e B
/M/N
7.
Sta
tus
U/E
/S
8.
Exp
lana
tion
Ste
m
Focu
s C
ues
T/F
Cre
d.
Dis
t. P
artia
l Jo
b-Li
nk
Min
utia
#/
un
its
Bac
k-w
ard
Q=
K/A
S
RO
O
nly
47
H
2 x
N
E
T2G
1 0
62 (A
C E
lect
Dis
t – lo
cal o
pera
tion
of b
reak
ers)
A4.
04
1.
Ste
m F
ocus
: Th
e st
em d
idn’
t inc
lude
whe
ther
the
plan
t was
in
an o
utag
e, e
tc.
Wha
t evo
lutio
n w
as b
eing
per
form
ed a
t Tim
e 02
00?
The
feed
er b
reak
er to
Bus
1E
A w
as in
itial
ly c
lose
d; w
hat
wer
e th
e op
erat
ors
doin
g w
hen
they
reco
gniz
ed th
e fe
eder
br
eake
r wou
ldn’
t ope
n re
mot
ely?
Sug
gest
pro
vidi
ng a
nsw
ers
to
thes
e qu
estio
n in
the
stem
.
2.
The
know
ledg
e of
whe
ther
XC
P-6
36, 5
-1 w
ill o
r will
not
ala
rm is
ov
er-s
hado
wed
by
the
fund
amen
tal c
once
pt th
at w
hen
DC
co
ntro
l pow
er is
rem
oved
to a
nyth
ing,
the
indi
catin
g lig
ht w
ill
extin
guis
h. S
ugge
st re
visi
ng th
e 2nd
par
t of t
he q
uest
ion
to te
st
whe
ther
or n
ot X
CP
-636
, 5-1
will
/ will
NO
T al
arm
. Th
e fir
st p
art
of th
e qu
estio
n te
sts
plan
t-spe
cific
kno
wle
dge
(AM
BE
R);
how
ever
, the
sec
ond
part
of th
e qu
estio
n ca
n be
ans
wer
ed b
y kn
owin
g G
FE K
/A 1
9100
8, B
reak
ers,
Rel
ays,
& D
isco
nnec
ts,
K1.
09:
Effe
cts
of …
rem
oval
of c
ontro
l pow
er o
n br
eake
r op
erat
ion.
3.
Ste
m F
ocus
: Th
ough
out
the
ques
tion,
it’s
not
cle
ar w
here
the
indi
catio
n be
ing
desc
ribed
is lo
cate
d. F
or e
xam
ple,
in th
e 2nd
st
em b
ulle
t, su
gges
t cla
rifyi
ng th
e m
ain
cont
rol r
oom
. A
lso,
in
the
2nd p
art o
f Cho
ices
B a
nd D
, sug
gest
cla
rifyi
ng m
ain
cont
rol
room
. O
ther
wis
e, a
n ap
plic
ant m
ay a
sk if
thes
e ite
ms
are
refe
rrin
g to
loca
l ind
icat
ion.
4.
Ste
m F
ocus
: S
ugge
st c
larif
ying
the
0240
bul
let a
s:
“The
clo
sing
and
trip
ping
DC
con
trol p
ower
bre
aker
s in
the
BU
S
1EA
FE
ED
BK
R c
ubic
le a
re o
pene
d lo
cally
.”
5.
Ste
m F
ocus
: Th
e 1st
fill-
in-th
e-bl
ank
stat
emen
t sho
uld
incl
ude
the
wor
d “o
n” in
stea
d of
“at.”
6.
Ste
m F
ocus
: Th
e 2nd
fill-
in-th
e-bl
ank
stat
emen
t sho
uld
incl
ude
“DC
” bef
ore
the
wor
d “c
ontro
l.”
7.
4-23
-18:
Com
men
ts in
corp
orat
ed; q
uest
ion
is S
AT.
Q
# 1.
LO
K
(F/H
)
2.
LOD
(1
-5)
3. P
sych
omet
ric F
law
s 4.
Job
Con
tent
Fla
ws
5. O
ther
6.
S
ourc
e B
/M/N
7.
Sta
tus
U/E
/S
8.
Exp
lana
tion
Ste
m
Focu
s C
ues
T/F
Cre
d.
Dis
t. P
artia
l Jo
b-Li
nk
Min
utia
#/
un
its
Bac
k-w
ard
Q=
K/A
S
RO
O
nly
48
H
2 x
x
x
N
E
T2G
1 0
63 (D
C E
lect
Dis
t – b
reak
ers
& c
ontro
l pow
er fu
ses)
A4.
01
1.
This
test
item
test
s th
e E
DG
sta
rt to
pic,
whi
ch is
sim
ilar t
o Q
#50;
su
gges
t get
ting
away
from
the
ED
G fo
r thi
s te
st it
em to
ens
ure
exam
bre
adth
of c
over
age.
2.
Ste
m F
ocus
: Th
e st
em s
houl
d be
div
ided
into
two
parts
: In
itial
C
ondi
tions
and
Cur
rent
Con
ditio
ns, s
imila
r to
the
othe
r tes
t ite
ms.
Thi
s w
ill m
ake
it cl
ear t
hat t
he fi
eld
brea
ker i
nitia
lly
tripp
ed o
pen
befo
re th
e B
us w
as d
e-en
ergi
zed.
3.
Ste
m F
ocus
: Th
e 3rd
bul
let p
hras
e “d
ue to
a m
echa
nica
l fai
lure
” is
not
nec
essa
ry.
4.
Par
tial:
The
wor
d “m
ust”
shou
ld b
e re
plac
ed w
ith th
e w
ord
“can
” in
the
2nd fi
ll-in
-the-
blan
k st
atem
ent t
o en
sure
no
post
-exa
m
com
men
ts.
5.
Ste
m F
ocus
: Th
e w
ord
“unl
oade
d” in
Cho
ices
A/B
is n
ot
nece
ssar
y.
6.
#/un
its:
The
2nd p
art o
f Cho
ices
B a
nd D
sho
uld
incl
ude
the
“XS
W” d
esig
nato
r, th
at is
, Bus
XS
W 1
DX
.
7.
4-20
-18:
Rew
rote
new
que
stio
n; n
ew q
uest
ion
is S
AT.
49
F 2
x
x
N
E
T2
G1
063
(DC
Ele
ct D
ist –
Pow
er to
Maj
or D
C lo
ads)
K2.
01
1.
Ste
m F
ocus
: Th
e 2nd
ste
m b
ulle
t sho
uld
be s
horte
ned,
the
reas
on is
not
nec
essa
ry.
Sug
gest
:
“Bat
tery
XB
A1X
BA
TTE
RY
1X
is lo
st.”
2.
Par
tial:
The
ste
m q
uest
ion
shou
ld b
e cl
arifi
ed to
ens
ure
a co
rrect
ans
wer
exi
sts:
“WO
OTF
com
pone
nts
has
lost
DC
pow
er?”
3.
4-18
-18:
Com
men
ts in
corp
orat
ed; q
uest
ion
is S
AT.
Q
# 1.
LO
K
(F/H
)
2.
LOD
(1
-5)
3. P
sych
omet
ric F
law
s 4.
Job
Con
tent
Fla
ws
5. O
ther
6.
S
ourc
e B
/M/N
7.
Sta
tus
U/E
/S
8.
Exp
lana
tion
Ste
m
Focu
s C
ues
T/F
Cre
d.
Dis
t. P
artia
l Jo
b-Li
nk
Min
utia
#/
un
its
Bac
k-w
ard
Q=
K/A
S
RO
O
nly
50
H
2 x
x
x x
X
M
E
T2G
1 0
64 (E
DG
-con
trol p
ower
) K
2.03
1.
This
test
item
test
s th
e E
DG
sta
rt to
pic,
whi
ch is
sim
ilar t
o Q
#48.
2.
Sou
rce
B/M
/N:
The
ques
tion
is li
sted
as
MO
DIF
IED
; how
ever
, th
e st
em is
exa
ctly
the
sam
e as
DC
26.
ES
-401
, Sec
tion
D.2
.f (p
age
9 of
52)
sta
tes:
“…bu
t sig
nific
antly
mod
ify e
ach
ques
tion
by c
hang
ing
at le
ast
one
perti
nent
con
ditio
n in
the
stem
and
at l
east
one
dis
tract
or.”
3.
Par
tial:
In th
e po
st-e
xam
revi
ew, a
n ap
plic
ant c
an s
ucce
ssfu
lly
argu
e th
at C
hoic
e C
(did
not
aut
o-st
art,
but c
an b
e lo
cally
st
arte
d) is
virt
ually
the
sam
e as
Cho
ice
D (d
id n
ot a
uto-
star
t but
ca
n be
loca
lly s
tarte
d w
ith a
ir va
lves
).
4.
Cre
d: C
hoic
e A
is n
ot p
laus
ible
bec
ause
of t
he p
hras
e “r
unni
ng
as d
esig
ned”
cou
ld p
oten
tially
mea
n th
e sa
me
thin
g as
Cho
ice
B, t
hat i
s, th
e E
DG
aut
o-st
arte
d an
d is
runn
ing
as d
esig
ned
with
th
e fie
ld d
e-en
ergi
zed.
5.
Cue
: C
hoic
e A
is m
issi
ng th
e w
ord
“aut
omat
ical
ly”,
like
the
othe
r Cho
ices
.
6.
4-23
-18:
Sin
ce q
uest
ion
has
a 2nd
kno
wle
dge
in e
ach
choi
ce,
this
qua
lifie
s as
a s
igni
fican
tly m
odifi
ed te
st it
em.
Com
men
ts
inco
rpor
ated
; que
stio
n is
SA
T.
Q
# 1.
LO
K
(F/H
)
2.
LOD
(1
-5)
3. P
sych
omet
ric F
law
s 4.
Job
Con
tent
Fla
ws
5. O
ther
6.
S
ourc
e B
/M/N
7.
Sta
tus
U/E
/S
8.
Exp
lana
tion
Ste
m
Focu
s C
ues
T/F
Cre
d.
Dis
t. P
artia
l Jo
b-Li
nk
Min
utia
#/
un
its
Bac
k-w
ard
Q=
K/A
S
RO
O
nly
51
H
2
x x
x
N
E/U
T2
G1
073
(Pro
cess
Rad
– in
terp
ret,
unde
rsta
nd)
G2.
2.44
1.
The
2nd p
art o
f the
test
item
ove
rlaps
the
oper
atin
g ex
am
scen
ario
s be
caus
e th
e cr
ews
will
revi
ew a
nd a
nnou
nce
the
EO
P-1
.0 (E
-0) f
old-
out p
age
requ
irem
ents
for e
very
reac
tor t
rip.
2.
Par
tial:
Sup
ply
Air
RM
-A1
has
thre
e ch
anne
ls (p
artic
ulat
e,
iodi
ne, g
aseo
us);
the
only
cha
nnel
that
act
uate
s th
e C
ontro
l R
oom
Bui
ldin
g E
mer
genc
y M
ode
of O
pera
tion
is th
e G
AS
EO
US
ch
anne
l. S
ince
the
stem
doe
s no
t inc
lude
any
RM
-A1
indi
catio
ns, t
here
is te
chni
cally
no
corr
ect a
nsw
er to
the
1st p
art
of th
e qu
estio
n.
3.
Q=K
/A:
The
Pro
cess
Rad
Mon
itorin
g to
pic
is n
ot b
eing
test
ed.
The
stem
indi
cate
s th
at a
LB
LO
CA
occ
urre
d, w
hich
initi
ates
the
Con
trol R
oom
Bui
ldin
g E
mer
genc
y M
ode
of O
pera
tion.
Eve
n th
ough
the
1st fi
ll-in
-the-
blan
k st
atem
ent s
ays
“As
a re
sult
of th
e R
M-A
1 al
arm
..”, t
he 1
st p
art o
f all
four
Cho
ices
tells
the
appl
ican
t tha
t the
Con
trol R
oom
Bui
ldin
g E
mer
genc
y M
ode
Act
uatio
n oc
curre
d. T
he a
pplic
ant’s
abi
lity
to in
terp
ret o
r ver
ify
the
stat
us o
f the
RM
-A1
is n
ot b
eing
test
ed.
Sug
gest
re-w
orki
ng
the
ques
tion
to re
solv
e C
omm
ent #
2 ab
ove,
whi
ch w
ill c
ontri
bute
to
reso
lvin
g th
is C
omm
ent #
3.
4.
Cre
d D
ist:
The
last
par
t of t
he 2
nd fi
ll-in
-the-
blan
k st
atem
ent
(“w
ithin
30
min
utes
”) in
jure
s th
e pl
ausi
bilit
y of
2nd
par
t of C
hoic
es
B/D
bec
ause
ver
ifyin
g th
at b
oth
Fans
are
runn
ing
isn’
t goi
ng to
be
som
ethi
ng th
at H
AS
to b
e do
ne fr
om th
e R
efer
ence
Pag
e of
E
OP
-1.0
(E-0
).
Sug
gest
mov
ing
the
phra
se “w
ithin
30
min
utes
” to
the
last
par
t of
onl
y C
hoic
es A
/C.
5.
Q
# 1.
LO
K
(F/H
)
2.
LOD
(1
-5)
3. P
sych
omet
ric F
law
s 4.
Job
Con
tent
Fla
ws
5. O
ther
6.
S
ourc
e B
/M/N
7.
Sta
tus
U/E
/S
8.
Exp
lana
tion
Ste
m
Focu
s C
ues
T/F
Cre
d.
Dis
t. P
artia
l Jo
b-Li
nk
Min
utia
#/
un
its
Bac
k-w
ard
Q=
K/A
S
RO
O
nly
52
H
2 x
x
x
x
N
U
T2G
1 0
76 (S
W –
pre
dict
/mon
itor R
BC
CW
& T
BC
CW
) A1.
02
1.
Q=K
/A:
The
prop
osed
test
item
doe
s no
t tes
t the
app
lican
ts’
abili
ty to
pre
dict
/mon
itor c
hang
es in
CC
W a
fter o
pera
ting
SW
co
ntro
ls.
Inst
ead,
the
prop
osed
test
item
test
s th
e ap
plic
ants
’ kno
wle
dge
of h
ow o
pera
ting
SW
con
trols
affe
cts
SW
coo
ling
(RB
te
mpe
ratu
re) t
o R
BC
Us.
2.
Ste
m F
ocus
: Th
e 3rd
bul
let i
s va
gue.
Was
the
Indu
stria
l Coo
ling
Mal
func
tion
the
reas
on fo
r MV
G-3
111A
, -31
12A
, and
-311
0A
clos
ures
? If
so,
then
sug
gest
com
bini
ng th
ese
bulle
ts.
If no
t, th
en c
onsi
der d
elet
ing
the
bulle
t, or
, alte
rnat
ivel
y, p
rovi
de m
ore
info
rmat
ion
to c
larif
y th
e bu
llet.
3.
Par
tial a
nd/o
r #/u
nits
: Th
e 5th
bul
let i
dent
ifies
RB
Tem
pera
ture
; ho
wev
er, t
his
may
not
be
the
sam
e as
Prim
ary
Con
tain
men
t A
vera
ge A
ir Te
mpe
ratu
re.
Is th
ere
a co
ntro
l roo
m in
dica
tor f
or
Ave
rage
Air
Tem
pera
ture
? If
so,
then
incl
ude
the
#/un
id in
the
stem
to e
nsur
e th
e ap
plic
ant c
an a
nsw
er th
e 1st
par
t of t
he
ques
tion
per T
S 3
.6.1
.5.
4.
Q
# 1.
LO
K
(F/H
)
2.
LOD
(1
-5)
3. P
sych
omet
ric F
law
s 4.
Job
Con
tent
Fla
ws
5. O
ther
6.
S
ourc
e B
/M/N
7.
Sta
tus
U/E
/S
8.
Exp
lana
tion
Ste
m
Focu
s C
ues
T/F
Cre
d.
Dis
t. P
artia
l Jo
b-Li
nk
Min
utia
#/
un
its
Bac
k-w
ard
Q=
K/A
S
RO
O
nly
53
H
2
x
x
B
U
T2G
1 0
78 (I
nstru
men
t Air
– A
ir P
ress
ure)
A3.
01
1.
Cre
d D
ist:
The
1st p
art o
f Cho
ices
C/D
(IP
V-2
659
auto
-clo
ses)
is
not
pla
usib
le b
ecau
se th
e st
em c
onta
ins
no v
alue
for R
B a
ir he
ader
pre
ssur
e. T
here
fore
an
appl
ican
t can
elim
inat
e C
hoic
es
C/D
bas
ed s
olel
y on
the
noun
nam
e of
IPV
-265
9 (In
stru
men
t Air
Sup
ply
to R
eact
or B
uild
ing
Air
Hea
der)
.
2.
Par
tial a
nd/o
r Min
utia
: In
the
post
-exa
m a
ppea
l spa
ce, a
n ap
plic
ant c
an s
ucce
ssfu
lly a
rgue
that
Cho
ice
B is
als
o co
rrec
t be
caus
e th
e IP
V-8
324
posi
tion
is u
ndef
ined
bet
wee
n 65
psi
g an
d 60
psi
g; th
e tra
inin
g m
ater
ials
onl
y sa
y th
at IP
V-8
324
is fu
lly
clos
ed a
t 60
psig
.
Sin
ce a
“rup
ture
” occ
urre
d (2
nd b
ulle
t) it
is m
inut
ia to
test
the
mom
enta
ry “p
artia
lly o
pen”
val
ve p
ositi
on b
ecau
se in
stru
men
t ai
r will
mos
t sur
ely
low
er b
elow
60
psig
.
Sin
ce n
othi
ng in
the
train
ing
mat
eria
ls s
tate
that
IPV
-832
4 w
ill
be “p
artia
lly o
pen”
ope
n at
65
psig
; the
refo
re, a
n ap
plic
ant c
an
succ
essf
ully
con
tend
that
ther
e is
no
corr
ect a
nsw
er fo
r the
2nd
pa
rt of
the
ques
tion.
Sug
gest
test
ing
the
appl
ican
ts’ k
now
ledg
e of
the
IPV
-832
4 po
sitio
n w
hen
inst
rum
ent a
ir he
ader
pre
ssur
e is
60
psig
.
3.
4-18
-18:
Com
men
ts in
corp
orat
ed; q
uest
ion
is S
AT.
54
H
2 x
x
x
B
E
T2G
1 10
3 (C
nmt–
pred
/mon
∆’s
pre
ss/te
mp/
hum
idity
w/ o
p ct
ls)
A1.
01
1.
Par
tial a
nd/o
r Min
utia
: U
nles
s th
e ca
vity
leve
l effe
ct is
ob
serv
able
, afte
r one
of t
he tw
o ex
haus
t fan
s is
sto
pped
with
the
equi
pmen
t hat
ch o
pen,
then
this
test
item
is v
ulne
rabl
e to
a
post
-exa
m a
ppea
l for
no
corr
ect a
nsw
er o
r min
utia
. S
OP
-114
, P
reca
utio
n #7
doc
umen
ts p
ast k
now
n “m
anom
eter
” effe
cts
with
th
e fu
el tr
ansf
er tu
be o
pen;
how
ever
, it d
oes
not t
ake
into
ac
coun
t the
ope
n eq
uipm
ent h
atch
. S
ugge
st m
odify
ing
the
test
ite
m to
mirr
or th
e sa
me
situ
atio
n pr
esen
ted
in S
OP
-114
, P
reca
utio
n #7
.
2.
Par
tial:
The
wor
d “w
ould
” sho
uld
be re
plac
ed w
ith th
e w
ord
“will
” in
the
stem
que
stio
n, to
ens
ure
one
and
only
one
cor
rect
an
swer
.
3.
Ste
m F
ocus
: Th
e 1st
bul
let i
s no
t nec
essa
ry.
Q
# 1.
LO
K
(F/H
)
2.
LOD
(1
-5)
3. P
sych
omet
ric F
law
s 4.
Job
Con
tent
Fla
ws
5. O
ther
6.
S
ourc
e B
/M/N
7.
Sta
tus
U/E
/S
8.
Exp
lana
tion
Ste
m
Focu
s C
ues
T/F
Cre
d.
Dis
t. P
artia
l Jo
b-Li
nk
Min
utia
#/
un
its
Bac
k-w
ard
Q=
K/A
S
RO
O
nly
55
F 2
x
x
N
E
T2
G1
103
(Cnm
t-los
s of
Cnm
t dur
ing
refu
elin
g) K
3.03
1.
Cre
d D
ist:
Cho
ice
A (n
o ac
tion
requ
ired
follo
win
g lo
ss o
f RH
R)
is n
ot p
laus
ible
bec
ause
dec
ay h
eat r
emov
al w
as lo
st w
ith th
e co
re fu
lly lo
aded
.
2.
Ste
m F
ocus
: Th
e 4th
bul
let m
ay b
e be
tter i
f it s
aid
that
bot
h do
ors
wer
e op
en (i
nste
ad o
f say
ing
neith
er p
erso
nnel
hat
ch
door
s w
ill c
lose
); if
neith
er d
oor w
ill c
lose
, the
n te
chni
cally
the
min
imum
requ
ired
actio
n to
clo
se a
t lea
st o
ne d
oor c
anno
t be
acco
mpl
ishe
d.
3.
Ste
m F
ocus
: Th
e 4th
bul
let p
hras
e “M
echa
nica
l Mai
nten
ance
re
ports
that
..” is
not
nec
essa
ry.
4.
One
rem
edy
may
be
to te
st th
e R
O a
pplic
ants
’ kno
wle
dge
of
whe
ther
LC
O 3
.6.1
.1 is
/ is
NO
T ap
plic
able
dur
ing
Ref
uelin
g.
56
H
2 x
x
B
E
T2G
2 0
01 (C
RD
-con
nect
ions
/rela
tions
hips
bet
wee
n N
IS/R
PS
) K1.
05
1.
Par
tial:
To
ensu
re C
hoic
e D
is n
ot a
lso
corr
ect,
re-w
ord
the
stem
que
stio
n so
that
bot
h st
atem
ents
refe
r to
the
curr
ent
cond
ition
s, li
ke:
“WO
OTF
com
plet
es th
e fo
llow
ing
stat
emen
ts fo
r the
se
cond
ition
s?”
2.
Ste
m F
ocus
: Th
e ph
rase
“by
the
pow
er le
vels
mea
sure
d” in
the
2nd fi
ll-in
-the-
blan
k st
atem
ent i
s no
t nec
essa
ry.
Sug
gest
:
“The
rod
bloc
k is
bei
ng c
ause
d by
__(
2)__
_. “
Q
# 1.
LO
K
(F/H
)
2.
LOD
(1
-5)
3. P
sych
omet
ric F
law
s 4.
Job
Con
tent
Fla
ws
5. O
ther
6.
S
ourc
e B
/M/N
7.
Sta
tus
U/E
/S
8.
Exp
lana
tion
Ste
m
Focu
s C
ues
T/F
Cre
d.
Dis
t. P
artia
l Jo
b-Li
nk
Min
utia
#/
un
its
Bac
k-w
ard
Q=
K/A
S
RO
O
nly
57
H
2
x
x
N
E
T2G
2 0
02 (R
CS
– im
plic
atio
ns o
f los
s fo
rced
circ
ulat
ion)
K5.
14
1.
Par
tial:
The
ste
m q
uest
ion
(WO
OTF
des
crib
ed th
e fir
st m
etho
d di
rect
ed in
EO
P-2
.1) a
sks
wha
t the
pro
cedu
re d
irect
s ve
rsus
w
hat i
s lis
ted
in th
e st
em.
Cho
ice
B is
als
o co
rrec
t.
2.
#/un
its a
nd/o
r Cre
d D
ist:
Dur
ing
the
adm
inis
tratio
n of
the
writ
ten
exam
, an
appl
ican
t may
ask
the
proc
tor “
Wha
t is
the
noun
nam
e of
PC
V-4
44C
and
-444
D?”
Is th
ere
VC
S g
uida
nce
as to
wha
t the
offi
cial
nou
n na
mes
are
fo
r val
ves?
Is
the
offic
ial n
oun
nam
e w
hat i
s lis
ted
in th
e S
OP
va
lve
lineu
p?
D
oes
the
Con
trol B
oard
nou
n na
me
incl
ude
the
RC
S
Loop
iden
tifie
r?
Unl
ess
the
offic
ial n
oun
nam
e fo
r bot
h va
lves
is o
nly
“PZR
S
PR
AY”
, the
n C
hoic
es A
/B m
ay n
ot b
e pl
ausi
ble
beca
use
the
stem
say
s R
CP
s A
& C
wer
e st
oppe
d du
e to
hig
h vi
brat
ion.
3.
4-18
-18:
Com
men
ts in
corp
orat
ed; q
uest
ion
is S
AT.
Q
# 1.
LO
K
(F/H
)
2.
LOD
(1
-5)
3. P
sych
omet
ric F
law
s 4.
Job
Con
tent
Fla
ws
5. O
ther
6.
S
ourc
e B
/M/N
7.
Sta
tus
U/E
/S
8.
Exp
lana
tion
Ste
m
Focu
s C
ues
T/F
Cre
d.
Dis
t. P
artia
l Jo
b-Li
nk
Min
utia
#/
un
its
Bac
k-w
ard
Q=
K/A
S
RO
O
nly
58
H
2 x
x
x
N
E
T2G
2 0
15 (
NI –
pre
dict
/mon
itor S
UR
∆’s
) A
1.02
1.
Par
tial:
Thi
s te
st it
em is
vul
nera
ble
to p
ost-e
xam
app
eals
of
mul
tiple
cor
rect
ans
wer
s. T
he w
ordi
ng o
f the
ste
m q
uest
ion
is
not p
reci
se; t
he w
ord
“clo
sest
” als
o im
plie
s th
ere
is n
o ex
act
Cho
ice.
An
appl
ican
t can
suc
cess
fully
con
tend
that
Cho
ices
A,
B, a
nd C
are
all
equa
lly c
orre
ct s
ince
they
all
repr
esen
t rel
ativ
ely
“clo
se” r
eact
or tr
ip S
UR
val
ues.
2.
Cue
: Th
e tim
e di
ffere
nce
betw
een
the
Initi
al C
ondi
tions
and
the
Cur
rent
Con
ditio
ns is
unk
now
n. T
he N
RO
ATC
pla
cing
one
SR
Tr
ain
A S
witc
h to
the
BLO
CK
pos
ition
, at s
ome
poin
t wel
l in
adva
nce
of T
ime
0404
, poi
nts
the
appl
ican
ts to
the
P-6
re
quire
men
t. S
ugge
st a
lso
incl
udin
g a
time
for t
he In
itial
C
ondi
tions
, tha
t is
oper
atio
nally
val
id, a
nd w
ithin
the
cont
ext o
f G
OP
-3, S
tep
3.13
.
3.
Cue
: Th
e 2nd
bul
let i
n th
e C
urre
nt C
ondi
tions
is n
ot n
eces
sary
.
4.
Ste
m F
ocus
: Th
e S
UR
is m
issi
ng fr
om th
e In
itial
Con
ditio
ns.
5.
Ste
m F
ocus
: A
ssum
ing
Com
men
t #1
was
n’t a
n is
sue,
the
stem
qu
estio
n co
uld
be s
tream
-line
d as
:
“WO
OTF
SU
R v
alue
s w
ill b
e pr
esen
t at T
ime
0406
?”
6.
Q
# 1.
LO
K
(F/H
)
2.
LOD
(1
-5)
3. P
sych
omet
ric F
law
s 4.
Job
Con
tent
Fla
ws
5. O
ther
6.
S
ourc
e B
/M/N
7.
Sta
tus
U/E
/S
8.
Exp
lana
tion
Ste
m
Focu
s C
ues
T/F
Cre
d.
Dis
t. P
artia
l Jo
b-Li
nk
Min
utia
#/
un
its
Bac
k-w
ard
Q=
K/A
S
RO
O
nly
59
H
2 x
x
x
M
E
T2G
2 0
16 (
NN
I – re
latio
nshi
p be
twee
n re
adin
gs a
nd a
ctua
l) A
3.02
1.
Cue
: Q
# 35
tells
the
appl
ican
ts th
at th
e M
aste
r Pre
ssur
e C
ontro
ller i
s re
late
d to
PC
V-4
44B
.
2.
Cue
: Th
e w
ord
“rap
idly
” (3rd
bul
let)
is n
ot n
eces
sary
to e
licit
the
corr
ect r
espo
nse.
3.
Ste
m F
ocus
: Th
e ph
rase
“..to
redu
ce p
ress
ure
durin
g a
trans
ient
suc
h as
the
one
abov
e”, i
n th
e 1st
ste
m q
uest
ion,
is n
ot
nece
ssar
y.
4.
Par
tial:
Why
is th
e bo
lded
und
erlin
ed s
ente
nce
nece
ssar
y? I
s th
is th
e ca
se a
t 100
% p
ower
? If
not
, the
n th
ere
may
be
no
corr
ect a
nsw
er to
the
ques
tion.
5.
Ste
m F
ocus
: Th
e 2nd
ste
m q
uest
ion
refe
rs to
con
trol b
oard
“m
eter
” for
the
“ass
ocia
ted
pres
sure
inst
rum
ent”,
whi
ch is
co
nfus
ing.
Sug
gest
cla
rifyi
ng th
e 2nd
ste
m q
uest
ion
as:
“Wha
t will
this
PO
RV
’s p
ress
ure
inst
rum
ent o
n th
e m
ain
cont
rol
boar
d be
read
ing
at th
e m
omen
t it f
irst l
ifts?
”
6.
4-23
-18:
Com
men
ts in
corp
orat
ed; q
uest
ion
is S
AT.
Q
# 1.
LO
K
(F/H
)
2.
LOD
(1
-5)
3. P
sych
omet
ric F
law
s 4.
Job
Con
tent
Fla
ws
5. O
ther
6.
S
ourc
e B
/M/N
7.
Sta
tus
U/E
/S
8.
Exp
lana
tion
Ste
m
Focu
s C
ues
T/F
Cre
d.
Dis
t. P
artia
l Jo
b-Li
nk
Min
utia
#/
un
its
Bac
k-w
ard
Q=
K/A
S
RO
O
nly
60
F 2
x
x
N
E
T2
G2
034
(Fue
l Han
dlin
g –
oper
ate/
mon
itor n
eutro
n le
vels
) A
4.02
1.
Par
tial:
An
appl
ican
t may
be
able
to s
ucce
ssfu
lly c
onte
nd a
ny o
f th
e fo
llow
ing,
for t
he re
ason
s pr
ovid
ed:
C
hoic
e B
may
als
o be
cor
rect
: S
OP
-404
, Sec
tion
IV.A
, S
tep
2.5
dire
cts
the
oper
ator
to s
et th
e S
R C
ount
er/S
cale
r Th
umbw
heel
to th
e de
sire
d tim
e in
terv
al.
The
stem
co
ntai
ns tw
o di
ffere
nt v
ersi
ons
of w
ordi
ng, w
hich
cou
ld
mak
e C
hoic
e B
cor
rect
. Th
e 3rd
bul
let s
ays
the
CR
S w
ants
to
redu
ce “t
he fr
eque
ncy
of th
e au
dibl
e be
epin
g of
the
Aud
io
Cou
nt R
ate”
, whe
reas
the
1st fi
ll-in
-the-
blan
k st
atem
ent i
s w
orde
d di
ffere
ntly
as
“cha
nge
the
time
perio
d be
twee
n th
e au
dibl
e be
eps.
” In
stru
men
tatio
n &
Con
trols
Cou
rse
Han
dout
IC-8
did
not
exp
lain
the
diffe
renc
e be
twee
n th
e S
R
Cou
nter
/Sca
ler T
hum
bwhe
el a
nd th
e A
udio
Mul
tiplie
r S
witc
h. F
or th
e A
udio
Mul
tiplie
r Sw
itch
in P
ositi
on 1
0, th
ere
will
be
one
“bee
p” fo
r eve
ry te
n co
unts
. Th
e C
ount
er/S
cale
r Th
umbw
heel
may
be
the
adju
stm
ent f
or th
e fre
quen
cy
betw
een
the
“bee
ps.”
C
hoic
e C
may
als
o be
cor
rect
: Th
e st
em s
ays
no fu
el w
ill
be m
oved
this
shi
ft. L
CO
3.9
.2 re
quire
s th
e au
dibl
e in
dica
tion
to b
e op
erab
le in
Mod
e 6.
How
ever
, Act
ion
A o
f th
e LC
O s
ays
that
if th
e au
dibl
e in
dica
tion
is n
ot o
pera
ble,
th
en c
ore
alte
ratio
ns m
ust b
e su
spen
ded.
The
refo
re, t
he
2nd p
art o
f the
que
stio
n m
ay b
e an
swer
ed th
at th
e A
udio
C
ount
rate
func
tion
is n
ot re
quire
d to
be
oper
able
“for
the
cond
ition
s ab
ove.
”
2.
Ste
m F
ocus
: Th
e ph
rase
“Aud
io C
ount
rate
func
tion”
in th
e 2nd
fil
l-in-
the-
blan
k st
atem
ent s
houl
d m
irror
LC
O 3
.9.2
, tha
t is,
“a
udib
le in
dica
tion.
”
3.
Ste
m F
ocus
: Th
is te
st it
em is
mis
sing
a s
tem
que
stio
n.
4.
4-23
-18:
Com
men
ts in
corp
orat
ed; q
uest
ion
is S
AT.
Q
# 1.
LO
K
(F/H
)
2.
LOD
(1
-5)
3. P
sych
omet
ric F
law
s 4.
Job
Con
tent
Fla
ws
5. O
ther
6.
S
ourc
e B
/M/N
7.
Sta
tus
U/E
/S
8.
Exp
lana
tion
Ste
m
Focu
s C
ues
T/F
Cre
d.
Dis
t. P
artia
l Jo
b-Li
nk
Min
utia
#/
un
its
Bac
k-w
ard
Q=
K/A
S
RO
O
nly
61
H
2 x
x
B
E
T2G
2 0
35 (S
G –
effe
ct o
f los
s/m
alfu
nctio
n of
MS
IVs)
K6.
01
1.
Par
tial:
Sin
ce th
e 1st
par
t of t
he q
uest
ion
incl
udes
a ti
mef
ram
e,
and
beca
use
the
term
“afte
r con
ditio
ns s
tabi
lize”
may
be
subj
ectiv
e, s
ugge
st re
visi
ng th
e 2nd
que
stio
n to
incl
ude
a tim
efra
me
also
.
2.
Ste
m F
ocus
: Th
e w
ord
“initi
al” i
n th
e 1st
ste
m q
uest
ion
is th
e sa
me
as “w
ithin
the
first
15
seco
nds.
” A
lso,
the
wor
d “w
ould
” le
nds
itsel
f to
subj
ectiv
ity.
Sug
gest
re-w
ordi
ng th
e 1st
ste
m
ques
tion
as:
“Whi
ch S
G le
vel(s
) will
incr
ease
with
in th
e fir
st 1
5 se
cond
s?”
3.
Ste
m F
ocus
: Th
e w
ord
“wou
ld” i
s su
bjec
tive
in th
e 1st
par
t of
each
Cho
ice;
sug
gest
cha
ngin
g to
“will
.”
4.
Ste
m F
ocus
: Th
e 3rd
ste
m b
ulle
t is
not n
eces
sary
.
5.
Par
tial:
The
wor
d “in
adve
rtent
ly” m
ay b
e be
tter a
s “fa
ils.”
“Fai
ls”
impl
ies
the
sprin
g pr
essu
re ra
pidl
y cl
osed
the
valv
e, w
hich
is th
e in
tent
of t
he te
st it
em.
6.
Dur
ing
prep
wee
k, w
e m
ay b
e ab
le to
see
this
eve
nt o
n th
e si
mul
ator
to v
alid
ate
the
answ
er.
7.
4-23
-18:
Com
men
ts in
corp
orat
ed p
endi
ng p
rep
wee
k va
lidat
ion;
qu
estio
n is
SA
T.
Q
# 1.
LO
K
(F/H
)
2.
LOD
(1
-5)
3. P
sych
omet
ric F
law
s 4.
Job
Con
tent
Fla
ws
5. O
ther
6.
S
ourc
e B
/M/N
7.
Sta
tus
U/E
/S
8.
Exp
lana
tion
Ste
m
Focu
s C
ues
T/F
Cre
d.
Dis
t. P
artia
l Jo
b-Li
nk
Min
utia
#/
un
its
Bac
k-w
ard
Q=
K/A
S
RO
O
nly
62
H
3 x
x
N
U
E
T2G
2 0
41 (S
team
Dum
p –
pow
er s
uppl
y to
ICS
inve
rter b
krs)
K2.
02
1.
Q=K
/A:
The
prop
osed
test
item
doe
s no
t tes
t the
app
lican
ts’
know
ledg
e of
the
pow
er s
uppl
y to
the
Ste
am D
ump
Con
trol
Sys
tem
(AP
N 5
907/
5908
). In
stea
d, th
e pr
opos
ed te
st it
em te
sts
the
appl
ican
ts’ k
now
ledg
e of
how
the
loss
of A
PN
590
2 af
fect
s th
e N
Is, w
hich
in tu
rn c
ause
s a
reac
tor t
rip.
Sug
gest
usi
ng a
test
item
that
test
s th
e ap
plic
ants
’ kno
wle
dge
of
whi
ch 1
20 V
AC
bus
the
Ste
am D
ump
Con
trol S
yste
m is
po
wer
ed fr
om, a
nd w
hich
inve
rter f
eeds
that
bus
. Fo
r exa
mpl
e:
The
SD
CS
is p
ower
ed fr
om 1
20V
AC
Bus
__(
1)__
, …
(AP
N 5
902
vs A
PN 5
908)
… w
hich
is fe
d vi
a th
e __
_(2)
___
Inve
rter.
(XIT
-590
1 vs
XIT
-590
2)
Not
e: S
afeg
uard
s P
ower
(GS
-2),
incl
udes
lear
ning
obj
ectiv
es
for t
he 1
20 V
AC
Inve
rter/B
us a
rran
gem
ent,
and
Enc
losu
re G
co
ntai
ns 1
20V
AC
load
s.
2.
Ste
m F
ocus
: G
OP
-4B
, Ste
p 3.
7 re
quire
s tra
nsfe
rrin
g ge
nera
tor
load
to th
e S
team
Dum
p S
yste
m w
hen
reac
tor p
ower
has
lo
wer
ed to
bet
wee
n 12
and
15%
. H
owev
er, S
tep
3.5.
g al
read
y ha
s S
team
Dum
ps p
lace
d in
the
Ste
am P
ress
ure
Mod
e. T
he
stem
con
ditio
ns s
ay th
at S
team
Dum
ps a
re in
the
Tavg
Mod
e.
Sug
gest
alig
ning
the
stem
with
the
GO
P-4
B c
ondi
tions
that
w
ould
exi
st a
t 13%
pow
er.
3.
#/un
its:
The
2nd p
art o
f Cho
ice
B m
ay c
onta
in s
lang
with
the
phra
se “t
he p
ot s
ettin
g”; t
he te
rmin
olog
y us
ed in
GO
P-4
B is
“m
/a s
tatio
n se
t poi
nt.”
4.
4-10
-18:
Com
men
t #1
is N
/A b
ecau
se K
/A s
wap
ped
out t
o 04
1 K
3.01
; IC
S is
Bab
cox
and
Wilc
ock
tech
nolo
gy.
5.
4-23
-18:
Que
stio
n is
SA
T.
Q
# 1.
LO
K
(F/H
)
2.
LOD
(1
-5)
3. P
sych
omet
ric F
law
s 4.
Job
Con
tent
Fla
ws
5. O
ther
6.
S
ourc
e B
/M/N
7.
Sta
tus
U/E
/S
8.
Exp
lana
tion
Ste
m
Focu
s C
ues
T/F
Cre
d.
Dis
t. P
artia
l Jo
b-Li
nk
Min
utia
#/
un
its
Bac
k-w
ard
Q=
K/A
S
RO
O
nly
63
H
2
x
x
N
E
T2G
2 0
45 (M
T G
en–p
redi
ct E
HC
mal
f, us
e pr
oced
ures
) A2.
17
1.
Cre
d D
ist:
Cho
ice
B (o
pen
MA
IN X
FMR
FE
ED
XC
B-8
902)
is
not p
laus
ible
bec
ause
ther
e is
not
hing
in th
e st
em th
at c
ould
be
mis
cons
trued
that
the
mai
n ge
nera
tor b
reak
er fa
iled
to o
pen
afte
r the
turb
ine
tripp
ed, a
nd b
ecau
se A
OP
-214
.1, E
-0, a
nd
othe
r pro
cedu
res
alw
ays
dire
ct v
erify
ing
the
GE
N B
KR
is o
pen.
S
ugge
st re
plac
ing
with
:
“B.
Ver
ify c
ontro
l rod
s ab
ove
RIL
.”
2.
Par
tial:
The
wor
ding
of t
he s
tem
que
stio
n co
uld
mak
e C
hoic
e D
a
corr
ect a
nsw
er, s
ince
AO
P-2
14.1
“dire
cts”
dep
ress
ing
both
M
AS
TER
TR
IP/E
ME
RG
EN
CY
TRIP
pus
hbut
tons
(RN
O fo
r Im
med
iate
Act
ion
Ste
p 3.
a).
A b
ette
r way
to w
ord
the
stem
que
stio
n m
ay b
e:
“Giv
en th
ese
cond
ition
s, W
OO
TF A
OP
-214
.1 s
teps
will
the
crew
per
form
?”
(Sin
ce C
hoic
e C
is n
ot fo
und
in A
OP
-214
.1, t
hen
cons
ider
re
plac
ing
it w
ith:
“C.
Ope
n M
VB
-101
, CN
DS
R A
& B
VA
C B
KR
”)
3.
#/un
its:
The
XC
P-6
26 te
rmin
olog
y sh
ould
be
cons
iste
nt w
ith
the
term
inol
ogy
used
in Q
#1.
64
H
2 x
x
B
E
T2G
2 0
55 (
CA
R –
kno
wle
dge
of C
AR
loss
on
cond
ense
r) K
3.01
1.
Par
tial:
Doe
s bo
th c
ross
-ove
r val
ves
not-f
ull-o
pen
caus
e a
dire
ct tu
rbin
e tri
p lo
gic
sign
al?
Bot
h cr
oss-
over
val
ves
mus
t be
open
ed fo
r CV
P “C
”, an
d cl
osin
g M
VB
-102
B w
ould
lose
va
cuum
.
2.
Ste
m F
ocus
: Th
e ph
rase
“Mai
n Tu
rbin
e tri
p du
e to
a” i
s no
t ne
cess
ary
in th
e st
em q
uest
ion.
3.
Ste
m F
ocus
: Th
e ph
rase
“out
put f
rom
” in
Cho
ice
A is
not
ne
cess
ary.
4.
4-18
-18:
Com
men
ts in
corp
orat
ed; q
uest
ion
is S
AT.
Q
# 1.
LO
K
(F/H
)
2.
LOD
(1
-5)
3. P
sych
omet
ric F
law
s 4.
Job
Con
tent
Fla
ws
5. O
ther
6.
S
ourc
e B
/M/N
7.
Sta
tus
U/E
/S
8.
Exp
lana
tion
Ste
m
Focu
s C
ues
T/F
Cre
d.
Dis
t. P
artia
l Jo
b-Li
nk
Min
utia
#/
un
its
Bac
k-w
ard
Q=
K/A
S
RO
O
nly
65
F 2
x x
M
E
T2
G2
068
(Liq
uid
RW
– d
esig
n fe
atur
es/in
terlo
cks)
K4.
01
1.
Cue
: Th
e w
ord
“com
plet
e” in
Cho
ice
C is
not
nec
essa
ry to
elic
it th
e co
rrect
resp
onse
.
2.
Ste
m F
ocus
: Th
e fir
st w
ord
“A” i
n ea
ch o
f the
Cho
ices
is n
ot
nece
ssar
y; th
e fo
ur C
hoic
es m
ay b
e sh
orte
ned
as:
A.
RM
-L5
low
sam
ple
flow
B
. Fa
irfie
ld P
enst
ocks
low
dilu
tion
flow
rate
C
. R
M-L
5 lo
ss o
f pow
er
D.
Was
te M
onito
r Tan
k lo
w le
vel
3.
W
as th
is te
st it
em u
sed
on th
e pr
evio
us tw
o N
RC
exa
ms
for t
he
K/A
068
K4.
01 to
pic?
(N
o)
4.
4-
18-1
8: C
omm
ents
inco
rpor
ated
; que
stio
n is
SA
T.
66
F 2
B
S
T3
G2.
1.1
(kno
wle
dge
of c
ondu
ct o
f ops
requ
irem
ents
)
Q
# 1.
LO
K
(F/H
)
2.
LOD
(1
-5)
3. P
sych
omet
ric F
law
s 4.
Job
Con
tent
Fla
ws
5. O
ther
6.
S
ourc
e B
/M/N
7.
Sta
tus
U/E
/S
8.
Exp
lana
tion
Ste
m
Focu
s C
ues
T/F
Cre
d.
Dis
t. P
artia
l Jo
b-Li
nk
Min
utia
#/
un
its
Bac
k-w
ard
Q=
K/A
S
RO
O
nly
67
F 2
x
x
M
E
S
AM
PLE
QU
ES
TIO
N R
EC
EIV
ED
12-
19-1
7
T3 G
2.1.
2
1.
Par
tial:
Dur
ing
the
pos
t-exa
m a
ppea
l pro
cess
, an
appl
ican
t co
uld
succ
essf
ully
con
tend
the
re is
no
corr
ect a
nsw
er to
the
2nd
part
of th
e qu
estio
n fo
r any
of
the
follo
win
g re
ason
s:
th
ere
is n
o gu
idan
ce th
at s
ays
if th
e tu
rnov
er o
ccur
red
late
th
e Te
ch S
pec
roun
ds a
bsol
utel
y st
ill h
as to
be
com
plet
ed
with
in th
e fir
st tw
o ho
urs
of a
nor
mal
shi
ft;
th
e w
ord
“sho
uld”
is n
ot a
requ
irem
ent,
i.e.,
OA
P-1
06.1
, O
pera
ting
Rou
nds,
Sec
tion
6.3
stat
es “T
ech
Spe
c R
ound
s sh
ould
be
take
n w
ithin
the
first
two
hour
s of
eac
h sh
ift”;
and
th
e 2nd
ste
m b
ulle
t (w
ord
“rel
ieve
d”) i
s sl
ang/
vagu
e.
2.
Ste
m F
ocus
: Th
e 2nd
ste
m b
ulle
t is
slan
g/va
gue;
the
prem
ise
shou
ld b
e cl
eare
r tha
t the
onc
omin
g op
erat
or d
idn’
t fin
ish
with
tu
rnov
er, a
nd d
idn’
t ass
ume
the
posi
tion,
unt
il 20
00.
3.
Ste
m F
ocus
: Th
e ph
rase
“by
a sp
ecifi
ed ti
me
perio
d” in
the
1st
fill-i
n-th
e-bl
ank
stat
emen
t is
not n
eede
d.
4.
Ste
m F
ocus
: Th
e st
em q
uest
ion
ends
with
“ IA
W O
AP
-106
.1”,
but t
he 1
st fi
ll-in
-the-
blan
k st
atem
ent i
s ba
sed
on O
AP
-100
.6.
5.
Ste
m F
ocus
: Th
e O
ATC
TR
EN
D R
OU
ND
S d
esig
natio
n sh
ould
al
so in
clud
e O
AP
-106
.1, A
ttach
men
t X.
Like
wis
e, th
e O
ATC
(M
OD
E 1
-4) T
EC
H S
PE
C R
OU
ND
S d
esig
natio
n sh
ould
als
o in
clud
e O
AP
-106
.1, A
ttach
men
t 1.
Q
# 1.
LO
K
(F/H
)
2.
LOD
(1
-5)
3. P
sych
omet
ric F
law
s 4.
Job
Con
tent
Fla
ws
5. O
ther
6.
S
ourc
e B
/M/N
7.
Sta
tus
U/E
/S
8.
Exp
lana
tion
Ste
m
Focu
s C
ues
T/F
Cre
d.
Dis
t. P
artia
l Jo
b-Li
nk
Min
utia
#/
un
its
Bac
k-w
ard
Q=
K/A
S
RO
O
nly
67
H
x
x
M
E
T3 G
2.1.
2 (k
now
ledg
e of
ope
rato
r res
pons
ibili
ties
all m
odes
)
Sam
ple
ques
tion
was
revi
sed
to e
limin
ate
the
wor
d “r
equi
red”
and
the
late
turn
over
sce
nario
des
crib
ed a
bove
; Ste
m F
ocus
Item
s pr
evio
usly
id
entif
ied
wer
e ei
ther
fixe
d or
do
not a
pply
. H
owev
er, t
he fo
llow
ing
new
flaw
s ex
ist:
1.
Par
tial a
nd/o
r Min
utia
: A
n ap
plic
ant c
an s
ucce
ssfu
lly c
onte
nd
that
Cho
ice
A is
als
o co
rrec
t, or
, sta
ted
in a
noth
er w
ay, i
t is
min
utia
to d
iffer
entia
te b
etw
een
0725
and
073
0 be
caus
e it
is
irrel
evan
t to
the
over
all i
nten
t of t
he 2
hou
r Tec
h S
pec
Rou
nds
Com
plet
ion
Exp
ecta
tion.
Sug
gest
cha
ngin
g th
e st
em ti
me
from
072
5 to
073
0 to
rem
edy.
2.
Cre
d D
ist:
Cho
ice
C (5
.8 h
ours
) is
not p
laus
ible
bec
ause
the
stem
say
s th
e da
y sh
ift a
ssum
ed th
e w
atch
at 0
725;
the
time
that
the
turn
over
mee
ting
star
ted
to b
e th
e tim
e th
e cr
ew
assu
med
the
wat
ch is
not
pla
usib
le.
Sug
gest
the
follo
win
g:
WO
OTF
com
plet
es th
e fo
llow
ing
stat
emen
t in
acco
rdan
ce w
ith
OA
P-1
06.1
, OP
ER
ATI
NG
RO
UN
DS
?
Tech
Spe
c R
ound
s sh
ould
be
take
n w
ithin
the
first
__(
1)__
__ ,
whe
n po
ssib
le.
(two
hour
s of
eac
h sh
ift v
s. h
alf o
f the
shi
ft)
3.
LOK
: Th
ere
may
be
too
few
Low
er C
og te
st it
ems
on th
e R
O
exam
; the
sug
gest
ion
in C
omm
ent 2
may
be
able
to h
elp
with
th
e qu
ota.
4.
4-23
-18:
Com
men
ts in
corp
orat
ed a
nd a
new
2nd
hal
f of t
he
ques
tion
was
dev
elop
ed.
Que
stio
n is
SA
T.
Q
# 1.
LO
K
(F/H
)
2.
LOD
(1
-5)
3. P
sych
omet
ric F
law
s 4.
Job
Con
tent
Fla
ws
5. O
ther
6.
S
ourc
e B
/M/N
7.
Sta
tus
U/E
/S
8.
Exp
lana
tion
Ste
m
Focu
s C
ues
T/F
Cre
d.
Dis
t. P
artia
l Jo
b-Li
nk
Min
utia
#/
un
its
Bac
k-w
ard
Q=
K/A
S
RO
O
nly
68
M
SA
MP
LE Q
UE
STI
ON
RE
CE
IVE
D 1
2-19
-17
T3 G
2.1.
43
1.
The
oper
atin
g te
st o
verla
ps th
e 2nd
par
t of t
his
test
item
sin
ce
the
appl
ican
ts w
ill b
e us
ing
Atta
chm
ent I
A (R
eact
ivity
Con
trol
Par
amet
ers)
dur
ing
the
scen
ario
s.
2.
Par
tial:
Dur
ing
the
post
-exa
m a
ppea
l pro
cess
, an
appl
ican
t co
uld
succ
essf
ully
con
tend
that
ther
e ar
e tw
o co
rrec
t ans
wer
s fo
r eac
h pa
rt of
the
ques
tion,
as
follo
ws:
R
eact
or E
ngin
eerin
g ca
lcul
ates
som
e of
the
inpu
ts n
eede
d by
the
RO
to c
ompl
ete
Atta
chm
ent I
A.
Ther
efor
e, R
eact
or
Eng
inee
ring
can
be in
dire
ctly
resp
onsi
ble
for c
alcu
latin
g th
e va
lues
con
tain
ed in
Atta
chm
ent I
A.
Th
e ro
d he
ight
afte
r a 1
0% p
ower
redu
ctio
n w
ithou
t a B
oric
A
cid
addi
tion
has
to b
e ca
lcul
ated
by
the
RO
and
writ
ten
on
Atta
chm
ent I
A; t
here
fore
, it i
s no
t “di
rect
ly re
ad” f
rom
the
Atta
chm
ent,
at le
ast n
ot in
itial
ly.
Sug
gest
the
follo
win
g:
In a
ccor
danc
e w
ith O
AP
-100
.6, C
ontro
l Roo
m C
ondu
ct a
nd
Con
trol o
f Shi
ft A
ctiv
ities
, Atta
chm
ent 1
A, R
eact
ivity
Con
trol
Par
amet
ers
shou
ld b
e m
aint
aine
d by
___
____
__ .
(the
RO
vs
Rea
ctor
Eng
inee
ring)
68
F 3
x
M
E
T3
G2.
1.43
(use
pro
cedu
res
dete
rmin
e ef
fect
s re
activ
ity o
f pla
nt ∆
s)
The
oper
atin
g te
st o
verla
p co
ncer
n in
the
Sam
ple
Que
stio
n (s
ee
abov
e) w
as a
ddre
ssed
by
test
ing
Atta
chm
ent I
B (R
eact
ivity
M
anag
emen
t Brie
f Mod
es 1
– 3
) ins
tead
of t
estin
g an
item
loca
ted
on
Atta
chm
ent I
A (R
eact
ivity
Con
trol P
aram
eter
s).
Als
o, th
e di
rect
/indi
rect
issu
e, a
s w
ell a
s th
e un
derly
ing
Rea
ctor
Eng
inee
ring
resp
onsi
bilit
y is
sue,
was
add
ress
ed b
y us
ing
the
exac
t wor
ds fr
om
OA
P-1
00.6
, Atta
chm
ent 1
A in
stea
d of
par
aphr
asin
g. H
owev
er, t
he
follo
win
g ne
w fl
aws
exis
t:
1.
Par
tial:
The
2nd
fill-
in-th
e-bl
ank
stat
emen
t atta
chm
ent s
houl
d re
fere
nce
OA
P-1
00.6
Atta
chm
ent I
B (R
eact
ivity
Man
agem
ent
Brie
f Mod
es 1
– 3
).
2.
4-20
-18:
Q
# 1.
LO
K
(F/H
)
2.
LOD
(1
-5)
3. P
sych
omet
ric F
law
s 4.
Job
Con
tent
Fla
ws
5. O
ther
6.
S
ourc
e B
/M/N
7.
Sta
tus
U/E
/S
8.
Exp
lana
tion
Ste
m
Focu
s C
ues
T/F
Cre
d.
Dis
t. P
artia
l Jo
b-Li
nk
Min
utia
#/
un
its
Bac
k-w
ard
Q=
K/A
S
RO
O
nly
69
F 2
x
x
x
M
U
T3
G2.
2.20
(pro
cess
for m
anag
ing
troub
lesh
ootin
g)
1.
Cre
d D
ist:
Cho
ices
A (G
ener
ate
an L
CO
) is
not p
laus
ible
be
caus
e an
RO
app
lican
t kno
ws
that
Q#6
9 is
an
RO
test
item
; R
O te
st it
ems
don’
t req
uire
an
appl
ican
t to
know
abo
ut
gene
ratin
g a
Rem
oval
& R
esto
ratio
n C
heck
She
et.
SA
P-0
205,
A
ttach
men
t III
iden
tifie
s sa
fety
sys
tem
s th
at h
ave
LCO
s. T
he
abili
ty to
gen
erat
e a
R&
R (t
rack
ing
or a
ctio
n) is
an
SR
O
resp
onsi
bilit
y.
2.
Cre
d D
ist:
Cho
ice
D (t
ry a
nd re
clos
e th
e br
eake
r aga
in) i
s no
t pl
ausi
ble
beca
use
of s
afet
y co
ncer
ns w
ith c
losi
ng th
e br
eake
r on
to a
n en
ergi
zed
Bus
; the
just
ifica
tion
for p
laus
ibili
ty w
as
asso
ciat
ed w
ith s
troke
tim
es o
n a
MO
V.
One
way
to fi
x th
e pl
ausi
bilit
y is
sue
is to
mod
ify th
e st
em to
say
the
brea
ker i
s in
th
e TE
ST
posi
tion.
3.
Par
tial:
Cho
ice
C c
an a
lway
s be
cor
rect
bec
ause
a
“trou
bles
hoot
ing
plan
” can
invo
lve
writ
ing
a w
ork
orde
r, et
c.
Sug
gest
usi
ng a
ban
k qu
estio
n th
at te
sts
how
man
y tim
es a
tri
pped
bre
aker
can
be
rese
t sin
ce th
is, i
n a
sens
e, is
“man
agin
g tro
uble
shoo
ting.
”
4.
Ste
m F
ocus
: Th
e pr
emis
e of
the
3rd b
ulle
t is
mis
sing
; was
the
crew
per
form
ing
SO
P-3
04, S
ectio
n IV
.A, T
rans
ferr
ing
BO
P
Bus
es F
rom
Nor
mal
to A
ltern
ate
Feed
? W
as th
e br
eake
r in
the
Test
pos
ition
whe
n it
faile
d to
clo
se?
5.
Ste
m F
ocus
: A
lthou
gh C
hoic
e A
is n
ot p
laus
ible
for t
he re
ason
in
Com
men
t #1,
it s
houl
d be
cla
rifie
d as
:
A.
Gen
erat
e a
Rem
oval
& R
esto
ratio
n C
heck
She
et IA
W
SA
P-0
205,
Sta
tus
Con
trol a
nd R
emov
al a
nd R
esto
ratio
n.
Q
# 1.
LO
K
(F/H
)
2.
LOD
(1
-5)
3. P
sych
omet
ric F
law
s 4.
Job
Con
tent
Fla
ws
5. O
ther
6.
S
ourc
e B
/M/N
7.
Sta
tus
U/E
/S
8.
Exp
lana
tion
Ste
m
Focu
s C
ues
T/F
Cre
d.
Dis
t. P
artia
l Jo
b-Li
nk
Min
utia
#/
un
its
Bac
k-w
ard
Q=
K/A
S
RO
O
nly
70
F 2
x x
x
x
N
U
T3
G2.
2.43
(pro
cess
to tr
ack
inop
ala
rms)
1.
Cre
d D
ist:
The
2nd
par
t of C
hoic
es B
/D (n
ot re
quire
d to
pe
riodi
cally
per
form
sur
veill
ance
trac
king
form
whi
le A
FD a
larm
is
bro
ken)
is n
ot p
laus
ible
bec
ause
the
stem
tells
the
appl
ican
t th
at th
e al
arm
is re
quire
d fo
r the
AFD
TS
Sur
veill
ance
re
quire
men
t. N
OT
perio
dica
lly p
erfo
rmin
g a
GTP
-702
AFD
su
rvei
llanc
e Fo
rm is
non
-con
serv
ativ
e.
2.
Job-
Link
: Th
e 1st
par
t of t
he q
uest
ion
goes
bey
ond
RO
kn
owle
dge
and
can
be s
ucce
ssfu
lly c
onte
sted
in th
e po
st-e
xam
ap
peal
spa
ce.
The
1st p
art o
f the
que
stio
n re
quire
s th
e ap
plic
ant
to k
now
that
a w
ork
orde
r can
not b
e us
ed to
trac
k in
oper
able
Te
ch S
pec
equi
pmen
t; th
e R
esto
ratio
n &
Rem
oval
Che
ck S
heet
m
ust s
tay
“ope
n.”
3.
Cue
: Th
e 1st
bul
let t
ells
the
appl
ican
t tha
t the
ann
unci
ator
is
asso
ciat
ed w
ith A
FD in
stea
d of
test
ing
the
appl
ican
ts’
know
ledg
e of
the
mea
ning
of C
OM
PTR
∆FL
UX
LM
T E
XC
EE
DS
(X
CP
-620
, 2-4
).
4.
Ste
m F
ocus
: Th
e ph
rase
“clo
sed
out t
o” in
the
1st fi
ll-in
-the-
blan
k st
atem
ent i
s sl
ang.
71
H
2
x
N
E/U
T3
G2.
3.5
(abi
lity
to u
se ra
d m
onito
ring
syst
ems)
1.
Q=K
/A:
The
prop
osed
test
item
is a
n ex
tens
ion
of T
ier 2
; the
pr
opos
ed te
st it
em te
sts
the
first
indi
cato
r of a
irbor
ne ra
diat
ion
in
the
Aux
iliar
y B
uild
ing
(RM
-A3,
Mai
n P
lant
Ven
t Exh
aust
Air
Mon
itor)
.
The
Tier
3 K
/A to
pic
requ
ires
test
ing
a ge
neric
adm
inis
trativ
e re
quire
men
t tha
t cou
ld p
erta
in to
any
radi
atio
n m
onito
ring
syst
em, s
uch
all A
RM
s, s
ourc
e ch
eck
requ
irem
ents
. Fo
r ex
ampl
e, H
PP
-904
, Use
of t
he R
adia
tion
Mon
itorin
g S
yste
m,
spec
ifies
the
adm
inis
trativ
e re
quire
men
ts fo
r whi
ch ra
diat
ion
mon
itor s
et p
oint
s th
at c
an b
e ad
just
ed b
y O
pera
tions
.
Q
# 1.
LO
K
(F/H
)
2.
LOD
(1
-5)
3. P
sych
omet
ric F
law
s 4.
Job
Con
tent
Fla
ws
5. O
ther
6.
S
ourc
e B
/M/N
7.
Sta
tus
U/E
/S
8.
Exp
lana
tion
Ste
m
Focu
s C
ues
T/F
Cre
d.
Dis
t. P
artia
l Jo
b-Li
nk
Min
utia
#/
un
its
Bac
k-w
ard
Q=
K/A
S
RO
O
nly
72
F 2
x
x
N
U
T3
G2.
3.7
(abi
lity
to c
ompl
y w
/ RW
P re
quire
men
ts)
1.
Cre
d D
ist:
The
1st p
art o
f Cho
ices
A/B
(Gen
eral
RW
P c
an b
e us
ed in
LH
RA
) is
not p
laus
ible
bec
ause
ent
erin
g a
LHR
A is
not
a
desi
rabl
e or
rout
ine
activ
ity.
2.
Par
tial:
The
RW
P p
rovi
ded
in th
e S
uppo
rting
Doc
umen
tatio
n in
dica
ted
that
a G
ener
al R
WP
doe
s co
ntai
n a
colu
mn
item
re
late
d to
Hot
Par
ticle
s; th
eref
ore,
Cho
ice
C is
als
o co
rrec
t.
Sug
gest
test
ing
VC
S-H
PP
-015
1 re
quire
men
t rel
ated
to G
ener
al
RW
Ps
are
used
whe
n th
e do
se to
an
indi
vidu
al a
re n
ot e
xpec
ted
to e
xcee
d 10
mr f
or a
sin
gle
entry
.
Ano
ther
idea
is to
test
the
RW
P p
roce
ss fo
r Ope
ratio
ns
Per
sonn
el d
urin
g an
Em
erge
ncy,
whe
n th
e tim
e to
use
the
norm
al R
WP
pro
cess
doe
sn’t
exis
t.
73
F 2
x
N
E
T3
G2.
4.1
(Kno
wle
dge
of E
OP
ent
ry c
ondi
tions
and
IOA
ste
ps)
1.
The
2nd p
art o
f the
test
item
(how
EO
P Im
med
iate
Act
ion
Ste
ps
are
mar
ked)
ove
rlaps
the
oper
atin
g ex
am b
ecau
se a
ll sc
enar
ios,
an
d po
ssib
le s
ome
JPM
s, w
ill h
ave
Imm
edia
te A
ctio
n S
teps
.
2.
Ste
m F
ocus
: N
one
of th
e bu
llete
d in
form
atio
n in
the
stem
is
nece
ssar
y, a
nd th
e 1st
par
t of t
he q
uest
ion
can
be s
impl
ified
. S
ugge
st:
WO
OTF
com
plet
es b
oth
stat
emen
ts IA
W O
AP
-103
.4,
EO
P/F
SP
/AO
P U
SE
R’S
GU
IDE
?
EO
P-6
.0, E
CA
-0.0
LO
SS
OF
ALL
ES
F A
C P
OW
ER
, ___
(1)_
__
ente
red
with
out f
irst e
nter
ing
EO
P-1
.0, E
-0 R
EA
CTO
R T
RIP
OR
S
AFE
TY IN
JEC
TIO
N.
EO
P-6
.0 c
onta
ins
___(
2)__
_ im
med
iate
act
ion
step
s.
Q
# 1.
LO
K
(F/H
)
2.
LOD
(1
-5)
3. P
sych
omet
ric F
law
s 4.
Job
Con
tent
Fla
ws
5. O
ther
6.
S
ourc
e B
/M/N
7.
Sta
tus
U/E
/S
8.
Exp
lana
tion
Ste
m
Focu
s C
ues
T/F
Cre
d.
Dis
t. P
artia
l Jo
b-Li
nk
Min
utia
#/
un
its
Bac
k-w
ard
Q=
K/A
S
RO
O
nly
74
F 5
x
N
E
T3
G2.
4.43
(Kno
wle
dge
of e
mer
genc
y co
mm
o/te
chni
ques
)
1.
Job-
Link
and
/or L
OD
=5:
An
RO
app
lican
t can
suc
cess
fully
co
nten
d th
at th
is te
st it
em te
sts
SRO
-onl
y kn
owle
dge,
and
goe
s be
yond
the
RO
job
resp
onsi
bilit
ies.
Dur
ing
our d
iscu
ssio
ns a
bout
usi
ng a
n A
.4 to
pic
(inst
ead
of A
.3)
for t
he R
Os,
you
indi
cate
d th
at o
pera
tors
at V
CS
do
not p
erfo
rm
emer
genc
y co
mm
unic
ator
dut
ies.
SA
P-1
02, S
tate
men
t of
Res
pons
ibili
ties
– O
pera
tions
, say
s th
at th
e S
hift
Test
Spe
cial
ist
perfo
rms
the
shift
com
mun
icat
or ro
le d
urin
g em
erge
ncie
s. I
s th
e S
TS a
n A
O?
If s
o, th
en p
erha
ps y
ou c
an te
st th
is K
/A to
pic,
si
nce
an R
O m
ust a
lso
be k
now
ledg
eabl
e of
AO
dut
ies.
Sug
gest
test
ing
any
diffe
renc
es b
etw
een
cont
rol r
oom
co
mm
unic
atio
ns re
quire
men
ts d
urin
g no
rmal
and
em
erge
ncy
situ
atio
ns.
Ano
ther
idea
is to
test
the
RO
app
lican
ts’ k
now
ledg
e of
wha
t the
ER
DS
is fo
r, or
oth
er e
mer
genc
y co
mm
unic
atio
ns
equi
pmen
t in
the
cont
rol r
oom
is fo
r.
If th
ere
is n
o te
stab
le in
form
atio
n, th
en w
e m
ay re
plac
e th
e K
/A.
75
F 2
x
N
E
T3
G2.
4.6
(Kno
wle
dge
of E
OP
miti
gatio
n st
rate
gies
)
1.
The
prop
osed
test
item
will
ove
rlap
Sce
nario
2.
2.
Ste
m F
ocus
: N
one
of th
e in
form
atio
n ab
ove
the
stem
que
stio
n is
nec
essa
ry.
Sug
gest
the
follo
win
g to
ens
ure
no o
verla
p w
ith S
cena
rio 2
:
WO
OTF
com
plet
es b
oth
stat
emen
ts IA
W O
AP
-103
.4,
EO
P/F
SP
/AO
P U
SE
RS
GU
IDE
? [N
ote:
Con
side
r eac
h st
atem
ent s
epar
atel
y.]
If co
ntro
l air
is lo
st d
urin
g th
rottl
ing
of E
FW to
mai
ntai
n S
G le
vel,
____
(1)_
___
to m
aint
ain
SG
leve
l is
perm
issi
ble.
(u
se o
f the
Mai
n C
ontr
ol B
oard
CM
C s
witc
h vs
som
e ot
her
plau
sibl
e ap
proa
ch)
If a
faul
ted
SG
has
bee
n po
sitiv
ely
iden
tifie
d, E
FW to
the
faul
ted
SG
sho
uld
be is
olat
ed _
__(2
)___
_.
(with
in te
n m
inut
es o
f the
bre
ak v
s. s
ome
othe
r pla
usib
le
activ
ity o
r act
ion)
Q
# 1.
LO
K
(F/H
)
2.
LOD
(1
-5)
3. P
sych
omet
ric F
law
s 4.
Job
Con
tent
Fla
ws
5. O
ther
6.
S
ourc
e B
/M/N
7.
Sta
tus
U/E
/S
8.
Exp
lana
tion
Ste
m
Focu
s C
ues
T/F
Cre
d.
Dis
t. P
artia
l Jo
b-Li
nk
Min
utia
#/
un
its
Bac
k-w
ard
Q=
K/A
S
RO
O
nly
76
H
2
x
x
x
B
U
T1G
1 0
38 (S
GTR
-via
ble
alte
rnat
ives
for p
laci
ng p
lant
in s
afe
cond
ition
whe
n co
nden
ser u
nava
ilabl
e) E
A2.
08
1.
Q=K
/A:
Cho
ice
A (S
G B
ackf
ill is
pre
ferre
d) is
alw
ays
pref
erre
d,
rega
rdle
ss o
f whe
n th
e co
nden
ser i
s/ is
not
ava
ilabl
e; th
eref
ore,
th
e ap
plic
ants
’ abi
lity
to a
sses
s vi
able
alte
rnat
ives
whe
n th
e co
nden
ser i
s no
t ava
ilabl
e is
not
bei
ng te
sted
.
Sug
gest
test
ing
the
appl
ican
ts’ a
bilit
y to
det
erm
ine
whe
ther
the
Blo
wdo
wn
proc
edur
e (E
OP
-4.1
B) c
an b
e us
ed w
hen
the
cond
ense
r is
unav
aila
ble,
or w
heth
er th
e S
team
Dum
p pr
oced
ure
(EO
P-4
.1C
) can
be
used
whe
n th
e co
nden
ser i
s un
avai
labl
e. F
or e
xam
ple,
sug
gest
cha
ngin
g th
e 1st
par
t of t
he
ques
tion
to te
st w
heth
er B
low
dow
n or
Ste
am D
ump
can/
cann
ot
be u
sed
whe
n th
e C
-9 p
erm
issi
ve is
una
vaila
ble.
The
2nd
par
t of
the
ques
tion
can
still
test
the
Wes
tingh
ouse
bas
is fo
r the
m
etho
d.
2.
Cue
: Th
e on
ly m
etho
d lis
ted
twic
e is
als
o th
e co
rrec
t ans
wer
. S
ugge
st p
icki
ng E
OP
-4.1
B, E
S-3
.2 P
OS
T-S
GTR
CO
OLD
OW
N
US
ING
BLO
WD
OW
N, a
s th
e 1st
par
t of C
hoic
e D
to e
nsur
e pa
ralle
lism
.
3.
Par
tial:
To
ensu
re th
e 2nd
par
t of e
ach
Cho
ice
mirr
ors
the
base
s w
ordi
ng (t
o m
inim
ize
the
poss
ibili
ty o
f no
corr
ect a
nsw
er),
chan
ge th
e 2nd
par
t of C
hoic
es A
and
C to
:
“min
imiz
es ra
diol
ogic
al re
leas
es”
And
the
2nd p
art o
f Cho
ices
B a
nd D
to:
“fast
est p
ost-S
GTR
coo
ldow
n m
etho
d”
4.
Par
tial:
Sug
gest
del
etin
g th
e 5th
bul
let.
Q
# 1.
LO
K
(F/H
)
2.
LOD
(1
-5)
3. P
sych
omet
ric F
law
s 4.
Job
Con
tent
Fla
ws
5. O
ther
6.
S
ourc
e B
/M/N
7.
Sta
tus
U/E
/S
8.
Exp
lana
tion
Ste
m
Focu
s C
ues
T/F
Cre
d.
Dis
t. P
artia
l Jo
b-Li
nk
Min
utia
#/
un
its
Bac
k-w
ard
Q=
K/A
S
RO
O
nly
77
N
E
/U
T1G
1 0
54 (L
oss
MFW
-det
erm
ine/
inte
rpre
t SF/
FF tr
end
reco
rder
)
1.
SR
O-o
nly:
The
cor
rect
ans
wer
to th
e pr
opos
ed te
st it
em c
an b
e de
duce
d us
ing
RO
kno
wle
dge
as fo
llow
s:
Fi
rst P
art:
Pla
nt p
aram
eter
ent
ry c
ondi
tions
to R
ed/O
rang
e P
ath
FRP
s is
RO
kno
wle
dge
(See
ES
-401
, Atta
chm
ent 2
, pa
ge 2
3 of
52)
. Fr
om a
n R
O o
vera
ll m
itiga
tive
stra
tegy
kn
owle
dge
pers
pect
ive,
the
FRP
s al
way
s ha
ve p
riorit
y,
afte
r tra
nsiti
onin
g ou
t of E
-0.
EO
P-1
2.0
(F-0
) ide
ntifi
es
that
, unl
ess
leas
t one
SG
leve
l is
> 41
% (a
dver
se
cont
ainm
ent),
a R
ED
pat
h ex
ists
. S
ince
all
SG
leve
ls a
re <
41
%, t
hen
the
1st p
art o
f the
que
stio
n ca
n be
ans
wer
ed
usin
g R
O k
now
ledg
e, th
at is
, exi
ting
EO
P-1
5.0
is n
ot
allo
wed
, bec
ause
FR
Ps
have
prio
rity.
S
econ
d P
art:
The
prio
ritiz
atio
n of
Wes
tingh
ouse
EO
Ps
(afte
r E-0
) is
E2
(faul
ted)
E3
(rupt
ured
)E
1(LO
CA
).
Sin
ce th
ere
is n
o S
GTR
, no
LOC
A, a
nd b
ecau
se th
e A
SG
is
faul
ted
(2nd
bul
let),
then
the
next
requ
ired
proc
edur
e is
E
OP
-3.0
(E-2
). P
lant
par
amet
ers
that
requ
ire d
irect
ent
ry
cond
ition
s in
to m
ajor
EO
Ps
is R
O k
now
ledg
e (E
S-4
01,
Atta
chm
ent 2
, pag
e 23
of 5
2).
If th
is K
/A d
oes
not l
end
itsel
f to
the
SR
O-le
vel,
then
we
can
disc
uss
repl
acin
g it.
78
H
3 z
z
N
E
SA
MP
LE Q
UE
STI
ON
RE
CE
IVE
D 1
2-19
-17
T1G
1 0
55 E
G2.
2.44
1.
Par
tial:
Dur
ing
the
post
-exa
m a
ppea
l pro
cess
, an
appl
ican
t can
su
cces
sful
ly a
rgue
that
ther
e is
no
corr
ect a
nsw
er b
ecau
se th
e R
CP
sea
l iso
latio
n va
lves
wer
e al
read
y cl
osed
at E
OP
6.0
, Ste
p 15
, bef
ore
trans
ition
ing
to E
OP
-6.2
. Th
eref
ore,
an
appl
ican
t can
co
nten
d fo
r the
2nd
par
t of t
he fi
ll-in
-the-
blan
k st
atem
ent t
hat
oper
ator
s w
ill N
OT
isol
ate
the
seal
inje
ctio
n be
fore
sta
rting
a
Cha
rgin
g P
ump,
bec
ause
sea
l inj
ectio
n w
as a
lread
y is
olat
ed
earli
er.
2.
LOK
: Th
e qu
estio
n w
as d
esig
nate
d as
a m
emor
y or
fu
ndam
enta
l kno
wle
dge
test
item
, eve
n th
ough
the
appl
ican
t ne
eds
to e
valu
ate
subc
oolin
g an
d E
OP
ste
ps to
obt
ain
the
corre
ct a
nsw
er.
3.
Ste
m F
ocus
: Th
e or
der o
f the
3rd
and
4th b
ulle
ts m
ay n
eed
to b
e re
vers
ed; s
eem
s m
ore
logi
cal.
Q
# 1.
LO
K
(F/H
)
2.
LOD
(1
-5)
3. P
sych
omet
ric F
law
s 4.
Job
Con
tent
Fla
ws
5. O
ther
6.
S
ourc
e B
/M/N
7.
Sta
tus
U/E
/S
8.
Exp
lana
tion
Ste
m
Focu
s C
ues
T/F
Cre
d.
Dis
t. P
artia
l Jo
b-Li
nk
Min
utia
#/
un
its
Bac
k-w
ard
Q=
K/A
S
RO
O
nly
78
H
3
x
N
E
T1G
1 0
55 (S
BO
-inte
rpre
t/und
erst
and
actio
ns/d
irect
ives
) EG
2.2.
4
The
obje
ctiv
e of
Sam
ple
Que
stio
n C
omm
ent #
1 (s
ee a
bove
) was
stil
l no
t ach
ieve
d; th
e re
vise
d qu
estio
n st
ill h
as v
irtua
lly th
e sa
me
flaw
: An
appl
ican
t can
con
tend
that
ther
e is
tech
nica
lly n
o co
rrec
t ans
wer
to
the
2nd p
art o
f the
que
stio
n be
caus
e th
e se
als
wer
e pr
evio
usly
is
olat
ed in
EO
P-6
.0 (E
CA
-0.0
), A
ttach
men
t 9, L
ocal
ly O
pera
ted
Isol
atio
n V
alve
s.
1.
Par
tial:
The
phr
ase
“will
dire
ct” i
n th
e 2nd
fill-
in-th
e-bl
ank
stat
emen
t is
subj
ectiv
e.
Is th
e 2nd
fill-
in-th
e-bl
ank
stat
emen
t say
ing
that
EO
P-6
.2 (E
CA
-0.
2) c
onta
ins
step
s to
isol
ate
the
seal
s?
Or i
s th
e st
atem
ent s
ayin
g th
at th
e op
erat
ors
will
isol
ate
the
RC
P s
eals
(for
the
first
tim
e) in
EO
P-6
.2 (E
CA
-0.2
)?
79
H
3 x
M
E
SA
MP
LE Q
UE
STI
ON
RE
CE
IVE
D 1
2-19
-17
T1G
1 0
58 A
A2.
02
1.
Let’s
dis
cuss
the
pros
and
con
s of
pro
vidi
ng T
ech
Spe
c 3.
8.2,
D
C S
ourc
es, t
o th
e ap
plic
ants
as
a re
fere
nce
for t
his
test
item
. P
ro:
Pro
vidi
ng th
e re
fere
nce
adds
pla
usib
ility
to s
ome
of th
e ch
oice
s, b
ut s
till a
llow
s te
stin
g th
e ap
plic
ants
’ kno
wle
dge
of
Tech
Spe
c 3.
0.3.
Con
s?
2.
Ste
m F
ocus
: S
ugge
st re
-wor
ding
the
first
sen
tenc
e to
put
initi
al
cond
ition
s be
fore
tim
elin
e. F
or e
xam
ple,
“The
uni
t is
in M
ode
3 w
ith a
pla
nt s
tartu
p in
pro
gres
s an
d B
atte
ry C
harg
er X
BC
-1A
-1B
is
inop
erab
le.”
3.
Ste
m F
ocus
: Th
e de
tails
in th
e 3rd
bul
let (
“..du
e to
indi
catio
ns o
f se
vere
cor
rosi
on a
t som
e ba
ttery
term
inal
s..”)
is n
ot n
eces
sary
.
4.
Ste
m F
ocus
: Th
e ha
sh-b
ulle
t in
the
6/10
/17
Tim
e 07
45 it
em c
an
be s
tream
lined
: “ -
One
(1) b
atte
ry c
ell d
oes
not m
eet t
he
surv
eilla
nce
volta
ge re
quire
men
t”
Q
# 1.
LO
K
(F/H
)
2.
LOD
(1
-5)
3. P
sych
omet
ric F
law
s 4.
Job
Con
tent
Fla
ws
5. O
ther
6.
S
ourc
e B
/M/N
7.
Sta
tus
U/E
/S
8.
Exp
lana
tion
Ste
m
Focu
s C
ues
T/F
Cre
d.
Dis
t. P
artia
l Jo
b-Li
nk
Min
utia
#/
un
its
Bac
k-w
ard
Q=
K/A
S
RO
O
nly
79
H
3
x
M
E
T1G
1 0
58 (
Loss
DC
Pow
er –
det
/inte
rp 1
25V
DC
bus
vol
t, lo
w/c
rit
low
, ala
rm)
AA
2.02
Sam
ple
Que
stio
n C
omm
ents
#2
and
#3 (s
ee a
bove
) wer
e in
corp
orat
ed; h
owev
er, t
he s
ampl
e qu
estio
n w
as c
hang
ed fr
om o
ne
conn
ecte
d ce
ll no
t mee
ting
its s
urve
illan
ce re
quire
men
t to
TWO
co
nnec
ted
cells
bot
h no
t mee
ting
thei
r SR
.
1.
Cue
: Tw
o ce
lls n
ot m
eetin
g th
eir S
R is
not
nec
essa
ry to
elic
it th
e co
rrect
resp
onse
.
80
H
2 x
x
N
E
T1G
1 0
77 (G
en G
rid D
istu
rban
ce –
TS
bas
es fo
r LC
Os)
AG
2.2.
25
1.
Par
tial:
The
wor
d “C
an” i
n th
e1st s
tem
que
stio
n is
vag
ue:
Is
the
ques
tion
aski
ng if
pro
cedu
res
allo
w a
ligni
ng
XTF
5052
to 1
DA
or 1
DB
with
a X
TF-5
Loc
kout
Con
ditio
n pr
esen
t? O
R
Is
the
ques
tion
aski
ng w
heth
er it
’s p
hysi
cally
pos
sibl
e to
al
ign
XTF
5052
to 1
DA
or 1
DB
whe
n a
XTF
-5 L
ocko
ut
Con
ditio
n?
Sin
ce th
e fir
st w
ord
(“C
an”)
is s
ubje
ctiv
e, th
is te
st it
em is
vu
lner
able
to p
ost-e
xam
com
men
ts re
late
d to
no
corr
ect a
nsw
er,
or C
hoic
e D
bei
ng th
e co
rrec
t ans
wer
.
2.
Ste
m F
ocus
: Th
e 2nd
Cur
rent
Con
ditio
ns b
ulle
t (re
acto
r has
tri
pped
) is
not n
eces
sary
.
3.
Ste
m F
ocus
: Th
e w
ord
“the”
may
be
mis
sing
afte
r the
firs
t wor
d in
the
2nd s
tem
que
stio
n: “
Is th
e X
TF50
52 ..
” A
lso,
the
wor
ds
“Alte
rnat
e A
C” s
houl
d be
inse
rted.
For
exa
mpl
e:
“Is th
e X
TF50
52 A
ltern
ate
AC
Sou
rce
cred
ited
in th
e sa
fety
an
alys
is, i
n ac
cord
ance
with
the
base
s fo
r TS
3.8
.1, A
C
Sou
rces
?”
Q
# 1.
LO
K
(F/H
)
2.
LOD
(1
-5)
3. P
sych
omet
ric F
law
s 4.
Job
Con
tent
Fla
ws
5. O
ther
6.
S
ourc
e B
/M/N
7.
Sta
tus
U/E
/S
8.
Exp
lana
tion
Ste
m
Focu
s C
ues
T/F
Cre
d.
Dis
t. P
artia
l Jo
b-Li
nk
Min
utia
#/
un
its
Bac
k-w
ard
Q=
K/A
S
RO
O
nly
81
F 2
x
x B
U
T1
G1
WE
05 (I
nade
q H
eat X
fer-
Loss
Sec
onda
ry H
eat S
ink
– sy
stem
se
t poi
nts,
inte
rlock
s, a
nd a
uto-
actio
ns a
ssoc
iate
d w
ith E
OP
ent
ry)
EG
2.4.
2
1.
SR
O-o
nly:
The
pro
pose
d te
st it
em te
sts
gene
ral
desi
gn/fu
nctio
n/ca
paci
ty o
f the
EFW
Sys
tem
(See
IB-3
, EFW
S
yste
m C
ours
e H
ando
ut, G
ener
al D
escr
iptio
n).
Eve
n th
ough
th
e E
FW S
yste
m c
apac
ity (t
o de
liver
380
gpm
to tw
o S
Gs
at
1211
psi
g) is
incl
uded
in th
e Te
ch S
pec
Bas
es, E
FW S
yste
m
capa
city
is R
O k
now
ledg
e.
2.
Q=K
/A:
The
prop
osed
test
item
doe
sn’t
test
the
appl
ican
ts’
know
ledg
e of
sys
tem
set
poi
nts,
inte
rlock
s, a
nd (o
r) a
uto-
actio
ns
as th
ey re
late
to E
OP
-15
(FR
-H.1
), Lo
ss o
f Sec
onda
ry H
eat
Sin
k, o
r as
they
rela
te to
a y
ello
w p
ath
in E
OP
-12.
0 (F
-0),
Mon
itorin
g of
CS
FSTs
.
82
F 2
x
x
x N
E
/U
T1G
2 0
76 (H
igh
Rx
Coo
lant
Act
ivity
– C
VC
S L
D fl
ow ra
te)
AA
2.05
1.
Q=K
/A a
nd/o
r SR
O-o
nly:
The
ent
ire K
/A m
ust b
e hi
t at t
he
SR
O-le
vel;
the
2nd p
ortio
n of
the
ques
tion,
whi
ch te
sts
the
CV
CS
LD
flow
rate
kno
wle
dge,
is R
O k
now
ledg
e of
the
over
all
miti
gativ
e st
rate
gy fo
r hig
h R
CS
act
ivity
. Th
is is
a to
ugh
K/A
.
It m
ay b
e di
fficu
lt to
hit
the
CV
CS
LD
flow
rate
por
tion
of th
e K
/A
at th
e S
RO
leve
l. H
ere
is o
ne w
ay th
at m
ay w
ork
for h
ittin
g th
e C
VC
S L
D fl
ow ra
te p
ortio
n of
the
K/A
at t
he S
RO
-leve
l:
Th
e te
st it
em c
ould
test
the
SR
O a
pplic
ants
’ kno
wle
dge
of
whe
ther
or n
ot th
e A
RP
pro
vide
s st
ep-b
y-st
ep g
uida
nce
to
max
imiz
e LD
flow
rate
, suc
h th
at S
OP
-102
is n
ot n
eede
d to
be
refe
rred
to a
nd th
e 2nd
par
t of t
he q
uest
ion
wou
ld s
till f
it th
e K
/A to
pic.
Thi
s w
ould
be
test
ing
proc
edur
e se
lect
ion
and
rela
ted
Tech
Spe
c B
ases
info
rmat
ion.
2.
Sin
ce th
e 2nd
par
t of a
ll fo
ur C
hoic
es is
uni
que,
the
1st p
art o
f the
te
st it
em is
not
bei
ng te
sted
.
3.
Ste
m F
ocus
: Th
e bo
lded
sen
tenc
e (A
SSU
ME
NO
OPE
RA
TOR
A
CTI
ON
S) c
onfli
cts
with
the
1st s
tem
que
stio
n.
82
4-
2-18
: R
epla
ced
K/A
with
AA
2.02
(Cor
rect
ive
actio
ns re
quire
d fo
r hi
gh fi
ssio
n pr
oduc
t act
ivity
in R
CS
.
Q
# 1.
LO
K
(F/H
)
2.
LOD
(1
-5)
3. P
sych
omet
ric F
law
s 4.
Job
Con
tent
Fla
ws
5. O
ther
6.
S
ourc
e B
/M/N
7.
Sta
tus
U/E
/S
8.
Exp
lana
tion
Ste
m
Focu
s C
ues
T/F
Cre
d.
Dis
t. P
artia
l Jo
b-Li
nk
Min
utia
#/
un
its
Bac
k-w
ard
Q=
K/A
S
RO
O
nly
83
H
2
x
M
E/U
T1
G2
WE
03 (L
OC
A C
oold
own/
Dep
ress
– e
xecu
te p
roce
dure
ste
ps)
1.
RO
Q#1
7 an
d Q
#41
alre
ady
test
the
know
ledg
e of
the
RW
ST
leve
l sw
ap o
ver v
alue
, as
wel
l as
the
RH
R S
ump
leve
l lim
it va
lue;
thes
e va
lues
are
requ
ired
for t
his
test
item
. D
uplic
atio
n an
d ov
erla
p be
twee
n th
e R
O te
st it
ems
and
this
test
item
sho
uld
be e
limin
ated
.
2.
Par
tial:
The
phr
ase
“che
cked
for a
pot
entia
l tra
nsiti
on” i
s su
bjec
tive;
an
appl
ican
t cou
ld c
onte
nd th
ere
is n
o co
rrec
t an
swer
, or n
ot e
noug
h in
form
atio
n pr
ovid
ed, s
ince
Sub
coo
ling,
E
FW, a
nd S
G N
R le
vels
are
n’t p
rovi
ded
para
met
ers.
The
sub
-bu
llet i
s co
nfus
ing
(“O
pera
tors
just
che
cked
for a
pot
entia
l tra
nsiti
on to
EO
P-1
.2, S
I Ter
min
atio
n.)”
Is th
e cr
ew a
t EO
P-2
.0, S
tep
10?
Or i
s th
e cr
ew a
t EO
P-2
.0, S
tep
20?
Not
e: T
he 2
nd p
ortio
n of
the
ques
tion
can
be a
nsw
ered
with
RO
kn
owle
dge
that
the
stea
m d
umps
are
n’t a
vaila
ble
durin
g a
loss
of a
ll of
fsite
pow
er; h
owev
er, s
ince
the
1st p
art o
f the
test
item
is S
RO
pr
oced
ure
sele
ctio
n re
late
d to
the
LOC
A C
oold
own/
Dep
ress
K/A
to
pic,
then
this
test
item
is a
ccep
tabl
e fo
r Q=K
/A a
nd S
RO
-onl
y.
84
F 2
x
x M
U
S
AM
PLE
QU
ES
TIO
N R
EC
EIV
ED
12-
19-1
7
T1G
2 W
E09
EG
2.1.
30
1.
Q=K
/A:
Sam
ple
plan
item
WE
09 is
iden
tifie
d on
pag
e 4.
5-23
of
the
PW
RK
/A C
atal
og a
s a
Wes
tingh
ouse
EO
P, w
hich
co
rres
pond
s to
EO
P-1
.3, N
atur
al C
irc C
oold
own,
at V
CS
. Th
e pr
opos
ed te
st it
em is
writ
ten
to te
st A
OP
-900
.02,
CR
A
band
onm
ent w
ith F
ire, e
ven
thou
gh th
e K
/A is
WE
09.
2.
SR
O O
nly:
It’s
not
cle
ar w
hich
10
CFR
55.4
3(b)
item
the
prop
osed
test
item
was
inte
nded
to ta
rget
. IF
the
inte
nt w
as to
ta
rget
55.
43(b
)(5)
[pro
cedu
re s
elec
tion]
, TH
EN
the
prop
osed
te
st it
em fa
lls s
hort
beca
use
the
stem
tells
the
appl
ican
t the
pr
oced
ure,
and
how
to c
oold
own
the
plan
t fro
m o
utsi
de th
e co
ntro
l roo
m c
an b
e an
ove
rall
miti
gativ
e st
rate
gy R
O
know
ledg
e. I
t’s m
uch
clea
ner f
rom
an
SR
O-o
nly
aspe
ct to
pr
ovid
e th
e ap
plic
ants
with
a c
hoic
e of
pro
cedu
res
whe
n 55
.43(
b)(5
) is
bein
g ta
rget
ed.
Q
# 1.
LO
K
(F/H
)
2.
LOD
(1
-5)
3. P
sych
omet
ric F
law
s 4.
Job
Con
tent
Fla
ws
5. O
ther
6.
S
ourc
e B
/M/N
7.
Sta
tus
U/E
/S
8.
Exp
lana
tion
Ste
m
Focu
s C
ues
T/F
Cre
d.
Dis
t. P
artia
l Jo
b-Li
nk
Min
utia
#/
un
its
Bac
k-w
ard
Q=
K/A
S
RO
O
nly
84
x 2
x x
x
N
E
T1
G2
WE
09 (N
at C
irc –
loca
te/o
pera
te c
ompo
nent
s/lo
cal)
EG
2.1.
30
A n
ew te
st it
em w
as p
rovi
ded
base
d on
the
Sam
ple
Que
stio
n co
mm
ents
(see
abo
ve);
how
ever
, the
follo
win
g ne
w fl
aws
exis
t:
1.
Cue
: Th
e 11
th b
ulle
t (5th
Cur
rent
Con
ditio
ns b
ulle
t) is
not
ne
cess
ary
to e
licit
the
corr
ect r
espo
nse.
2.
Cre
d D
ist:
Cho
ice
D (g
o to
EO
P-1
.4 S
team
Voi
d) is
not
pl
ausi
ble
beca
use
the
stem
con
tain
s no
info
rmat
ion
that
cou
ld
be m
isco
nstru
ed a
s a
larg
e va
riatio
n in
PZR
leve
l, or
a R
VLI
S
indi
catio
n va
lue.
3.
Ste
m F
ocus
: Th
e ph
rase
“and
incr
ease
coo
ldow
n ra
te” i
n C
hoic
es A
and
D is
not
nec
essa
ry.
4.
LOK
: Th
e pr
opos
ed te
st it
em a
ppea
rs to
be
high
er c
og; l
et’s
di
scus
s.
85
H
3 x
x
N
U
T1G
2 W
E14
(Los
s of
CTM
T –
adhe
re to
pro
cedu
res)
EA
2.2
Not
e: W
E14
is H
igh
Con
tain
men
t Pre
ssur
e (K
/A C
atal
og p
age
4.5-
37);
at V
CS
this
is th
e eq
uiva
lent
of E
OP
-17.
0 (F
R-Z
.1),
Res
pons
e to
H
igh
Rea
ctor
Bui
ldin
g P
ress
ure.
1.
Q=K
/A:
The
prop
osed
test
item
test
s th
e ap
plic
ants
’ abi
lity
to
dete
rmin
e th
at th
e hi
ghes
t req
uire
d E
AL
clas
sific
atio
n is
due
to:
th
e lo
ss o
f the
RC
S B
arrie
r (S
I req
uire
d du
e to
SG
TR)
-com
bine
d w
ith-
th
e lo
ss o
f the
Con
tain
men
t Bar
rier (
rupt
ured
SG
faul
ted
outs
ide
of c
onta
inm
ent v
ia s
tuck
ope
n P
OR
V)
The
inte
nt o
f the
hig
h co
ntai
nmen
t pre
ssur
e E
OP
-17.
0 to
pic
is
not b
eing
test
ed, s
ince
nei
ther
a E
AL
clas
sific
atio
n ba
sed
on
high
con
tain
men
t pre
ssur
e, n
or th
e E
OP
-17.
0 pr
oced
ure
sele
ctio
n to
pic,
is b
eing
test
ed.
One
way
to te
st th
e E
OP
-17.
0 to
pic
via
the
E-p
lan
is E
AL
Cha
rt S
yste
m F
unct
ion
8 (C
TMT
Isol
atio
n Fa
ilure
) SU
8.2,
C
onta
inm
ent p
ress
ure
> 12
psi
g A
ND
< o
ne fu
ll tra
in o
f de
pres
suriz
atio
n eq
uipm
ent (
Tabl
e S
-4) o
pera
ting
per d
esig
n fo
r >
15 m
inut
es.
2.
Ste
m F
ocus
: Th
e w
ord
“that
” in
the
2nd fi
ll-in
-the-
blan
k st
atem
ent i
s su
bjec
tive.
Q
# 1.
LO
K
(F/H
)
2.
LOD
(1
-5)
3. P
sych
omet
ric F
law
s 4.
Job
Con
tent
Fla
ws
5. O
ther
6.
S
ourc
e B
/M/N
7.
Sta
tus
U/E
/S
8.
Exp
lana
tion
Ste
m
Focu
s C
ues
T/F
Cre
d.
Dis
t. P
artia
l Jo
b-Li
nk
Min
utia
#/
un
its
Bac
k-w
ard
Q=
K/A
S
RO
O
nly
86
H
2
x
x
N
U
SA
MP
LE Q
UE
STI
ON
RE
CE
IVE
D 1
2-19
-17
T2G
1 0
04 G
2.4.
47
1.
SR
O-o
nly:
Pla
nt p
aram
eter
AO
P e
ntry
con
ditio
ns is
RO
kn
owle
dge;
the
first
par
t of t
he q
uest
ion
is te
stin
g th
e kn
owle
dge
that
whe
n in
Mod
e 1
or 2
, the
n A
OP
-101
.1 is
requ
ired.
The
title
of
AO
P-1
12.1
is S
hutd
own
LOC
A a
nd th
e un
it is
in M
ode
3.
Mod
e 3
is H
ot S
tand
by.
2.
SR
O-o
nly:
Sin
ce th
e 2nd
par
t of a
ll fo
ur c
hoic
es is
uni
que,
then
an
app
lican
t can
det
erm
ine
the
corr
ect a
nsw
er w
ithou
t kno
win
g th
e an
swer
to th
e 1st
par
t of t
he q
uest
ion.
3.
Cre
d D
ist:
An
appl
ican
t can
elim
inat
e C
hoic
e D
with
out k
now
ing
anyt
hing
abo
ut th
e ev
olut
ion.
The
1st p
art o
f Cho
ice
D (L
oss
of
Coo
lant
NO
T re
quiri
ng S
I) co
nflic
ts w
ith th
e 2nd
par
t of C
hoic
e D
(fi
rst a
ctio
n is
to in
itiat
e S
I). I
f the
app
lican
t use
d th
at lo
gic
to
elim
inat
e C
hoic
e D
, he/
she
wou
ld b
e co
rrec
t.
86
H
2
x
N
E/U
T2
G1
004
(C
VC
S –
dia
gnos
e/re
cogn
ize
trend
s w
ref m
at’l)
G2.
4.47
Sam
ple
ques
tion
Com
men
t #2
and
#3 (s
ee a
bove
) wer
e in
corp
orat
ed; h
owev
er, C
omm
ent #
1 w
as n
ot a
ddre
ssed
in th
e re
vise
d te
st it
em.
1.
SR
O-o
nly:
The
firs
t and
2nd
par
ts o
f the
que
stio
n ca
n be
an
swer
ed w
ith R
O k
now
ledg
e:
1st
par
t: T
he U
nit i
s in
Mod
e 4;
ther
efor
e, th
e co
rrec
t pr
oced
ure
is th
e A
OP
for S
hutd
own
Mod
es, w
hich
is A
OP
-11
2.1,
Shu
tdow
n LO
CA
. R
Os
are
requ
ired
to k
now
pla
nt
mod
es; t
he ti
tle o
f AO
P-1
12.1
is “S
hutd
own.
”
2nd
par
t: T
he o
vera
ll A
OP
-112
.1 m
itiga
tive
stra
tegy
is R
O
know
ledg
e, w
hich
is u
sing
the
char
ging
sys
tem
into
the
cold
legs
vs
the
norm
al c
harg
ing
flow
pat
h.
If th
is K
/A is
diff
icul
t to
test
at t
he S
RO
leve
l, th
en w
e ca
n di
scus
s re
plac
ing
the
K/A
.
Q
# 1.
LO
K
(F/H
)
2.
LOD
(1
-5)
3. P
sych
omet
ric F
law
s 4.
Job
Con
tent
Fla
ws
5. O
ther
6.
S
ourc
e B
/M/N
7.
Sta
tus
U/E
/S
8.
Exp
lana
tion
Ste
m
Focu
s C
ues
T/F
Cre
d.
Dis
t. P
artia
l Jo
b-Li
nk
Min
utia
#/
un
its
Bac
k-w
ard
Q=
K/A
S
RO
O
nly
87
H
3 x
x
x x
B
E/U
T2
G1
005
(RH
R-p
redi
ct im
pact
RH
R v
lv m
alf,
use
proc
’s)
A2.
02
2016
NR
C E
xam
1.
Cue
and
/or C
red
Dis
t: T
he 1
st s
ub-b
ulle
t (O
pera
tors
read
ing
Ste
p 6
wor
ds),
and
the
last
sub
-bul
let (
MV
G-8
812B
), ar
e no
t ne
cess
ary
to e
licit
the
corr
ect r
espo
nse.
Cho
ices
A/B
(sta
y in
EO
P-2
.2 (E
S-1
.3))
are
not
pla
usib
le w
ith a
ll of
the
sub-
bulle
t inf
orm
atio
n pr
esen
ted
the
way
that
it is
.
2.
Cue
: Th
e la
st p
ortio
ns o
f the
2nd
par
t of C
hoic
es A
/B (t
o re
ener
gize
bus
/loca
lly s
tart
ED
G) a
re n
ot n
eces
sary
to e
licit
the
corr
ect r
espo
nse.
Ins
tead
, sug
gest
re-w
orki
ng th
e 2nd
par
t of
Cho
ices
A/B
as
AO
P-3
04.1
A e
ntry
is/ i
s N
OT
requ
ired.
3.
Par
tial:
To
ensu
re th
e an
swer
s ar
e no
t sub
ject
ive,
sug
gest
de
letin
g th
e la
st p
hras
e of
the
stem
que
stio
n (“
..to
mai
ntai
n co
re
cool
ing”
)
4.
Ste
m F
ocus
and
/or C
ue:
The
last
phr
ase
in C
hoic
e C
(“..t
o pr
eser
ve th
e R
WS
T”) i
s no
t nec
essa
ry.
5.
Ste
m F
ocus
and
/or C
ue:
The
last
phr
ase
in C
hoic
e D
(“..t
o m
aint
ain
a w
ater
sou
rce
for C
harg
ing”
) is
not n
eces
sary
.
6.
Ste
m F
ocus
: Th
e 3rd
ste
m b
ulle
t inc
lude
s th
e w
ord
“just
”, w
hich
in
terje
cts
even
t tim
elin
e co
nfus
ion;
did
the
XTF
004
Lock
out
happ
en b
efor
e th
e “A
” ED
G s
topp
ed?
Q
# 1.
LO
K
(F/H
)
2.
LOD
(1
-5)
3. P
sych
omet
ric F
law
s 4.
Job
Con
tent
Fla
ws
5. O
ther
6.
S
ourc
e B
/M/N
7.
Sta
tus
U/E
/S
8.
Exp
lana
tion
Ste
m
Focu
s C
ues
T/F
Cre
d.
Dis
t. P
artia
l Jo
b-Li
nk
Min
utia
#/
un
its
Bac
k-w
ard
Q=
K/A
S
RO
O
nly
88
H
3 x
x
N
U
T2G
1 0
08 (C
CW
-per
form
pro
cedu
res
all m
odes
) G
2.1.
23
1.
Cre
d D
ist:
The
1st p
art o
f Cho
ices
C/D
(B C
CW
ope
rabl
e w
ith
brea
ker f
ailu
re is
sue)
is n
ot p
laus
ible
bec
ause
the
stem
say
s th
at th
e “C
” CC
W P
ump
Bre
aker
has
a p
robl
em, a
nd it
is a
ligne
d to
the
“B” L
oop.
Sug
gest
revi
sing
the
last
bul
let t
o sa
y:
“C” C
CW
is O
FF, a
ligne
d el
ectri
cally
to th
e “B
” Loo
p, a
nd it
s su
pply
bre
aker
is ra
cked
UP
.”
2.
Ste
m F
ocus
: Th
e ph
rase
“with
in th
e ne
xt 4
8 ho
urs”
is n
ot
nece
ssar
y. W
hy is
it in
clud
ed?
The
2nd
ste
m q
uest
ion
can
be
sim
ply
put a
s:
“Is M
OD
E 4
ent
ry a
llow
ed in
the
curr
ent c
ondi
tion?
”
3.
Ste
m F
ocus
: Th
e w
ords
“the
ass
ocia
ted”
, in
the
3rd a
nd 4
th
bulle
ts, a
re n
ot n
eces
sary
. S
ugge
st s
horte
ning
eac
h C
hoic
e to
:
“A” C
CW
pum
p is
runn
ing
with
its
switc
h in
NO
RM
AL
AFT
ER
S
TAR
T”
89
H
2 x
x
x
N
U
T2G
1 0
64 (E
DG
- pre
d lo
ad, V
AR
S, a
ir co
mp;
use
pro
cs)
A2.
02
1.
SR
O-o
nly:
The
1st p
art o
f the
test
item
can
be
answ
ered
bas
ed
on R
O k
now
ledg
e th
at a
ED
G a
uto-
star
t req
uire
s us
ing
SO
P-
306
to e
nsur
e eq
uipm
ent a
lignm
ent a
nd to
adj
ust b
us
frequ
ency
/vol
tage
, and
pla
nt p
aram
eter
AO
P e
ntry
con
ditio
ns.
2.
Par
tial:
Cho
ice
C (E
nter
AO
P-3
01.1
firs
t) is
als
o co
rrec
t be
caus
e th
ere
is n
o V
CS
pro
cedu
re th
at p
rovi
des
guid
ance
on
whi
ch o
f the
se tw
o pr
oced
ures
is re
quire
d to
be
ente
red
first
; bo
th p
roce
dure
s ar
e ap
plic
able
to th
e st
em c
ondi
tions
, and
co
uld
also
be
impl
emen
ted
conc
urre
ntly
.
3.
Ste
m F
ocus
: Th
e C
hoic
es fo
r the
2nd
par
t of t
he q
uest
ion
shou
ld
be w
orde
d as
“is/
is N
OT
requ
ired.
” Th
is w
ay, t
he a
pplic
ants
’ kn
owle
dge
of th
e lo
gic
is m
ore
clea
rly b
eing
test
ed, i
nste
ad o
f ha
ving
the
Cho
ices
wor
ded
as “w
ill/ w
ill N
OT.
”
Q
# 1.
LO
K
(F/H
)
2.
LOD
(1
-5)
3. P
sych
omet
ric F
law
s 4.
Job
Con
tent
Fla
ws
5. O
ther
6.
S
ourc
e B
/M/N
7.
Sta
tus
U/E
/S
8.
Exp
lana
tion
Ste
m
Focu
s C
ues
T/F
Cre
d.
Dis
t. P
artia
l Jo
b-Li
nk
Min
utia
#/
un
its
Bac
k-w
ard
Q=
K/A
S
RO
O
nly
90
H
3 x
B
E
T2G
1 0
73 (P
RM
-pre
dict
det
ecto
r fai
lure
, use
pro
cedu
res)
A2.
02
1.
Ste
m F
ocus
: S
ugge
st re
plac
ing
the
wor
d “h
as” w
ith “w
as” i
n th
e 3rd
bul
let t
o be
chr
onol
ogic
ally
acc
urat
e w
ith th
e tim
elin
e.
2.
Ste
m F
ocus
: S
ugge
st in
clud
ing
“Act
ion
B” i
n th
e 4th
ste
m b
ulle
t, an
d sh
orte
ning
the
title
of T
S 3
.4.6
as:
“Man
ual l
eak
rate
cal
cula
tions
are
bei
ng d
one
to s
atis
fy
Sur
veill
ance
4.4
.6.2
.1.d
in a
ccor
danc
e w
ith A
ctio
n B
of T
S 3
.4.6
, R
EA
CTO
R C
OO
LAN
T S
YS
TEM
LE
AK
AG
E.”
NO
TE:
TSR
100
7 (P
age
afte
r TS
Pag
e 3/
4 0-
2) s
tate
s th
at th
e 25
%
exte
nsio
n ca
n’t b
e us
ed fo
r act
ion
stat
emen
ts.
91
H
2
x
x
M
E
T2G
2 0
11 (P
ZRLC
- int
erpr
et C
R in
dica
tion,
ver
ify s
tatu
s) G
2.2.
44
1.
Cue
: Th
e 13
00 b
ulle
t use
of t
he p
lura
l for
m o
f pro
blem
(s) i
s no
t ne
cess
ary
to e
licit
the
corr
ect r
espo
nse.
Sug
gest
cha
ngin
g it
to:
“Cur
rent
tim
e is
130
0:
No
corr
ectiv
e m
aint
enan
ce h
as b
een
com
plet
ed.”
2.
Cue
: P
rovi
ding
OA
P-1
06.1
, Atta
chm
ent 1
, Pag
es 2
9 &
30
is n
ot
nece
ssar
y to
elic
it th
e co
rrec
t res
pons
e; s
ugge
st o
nly
prov
idin
g TS
Pag
e 3/
4 3-
3. T
he 1
st p
art o
f bot
h ch
oice
s is
not
75%
pow
er;
ther
efor
e, t
he a
pplic
ants
kno
w th
ere
is m
ore
than
one
cha
nnel
fa
ilure
.
3.
Par
tial:
The
phr
ase
“this
con
ditio
n w
as” i
n th
e 2nd
fill-
in-th
e-bl
ank
stat
emen
t is
vagu
e; s
ugge
st re
plac
ing
with
“the
pow
er
leve
l is”
, for
exa
mpl
e:
The
earli
est t
ime
at w
hich
the
pow
er le
vel i
s re
quire
d to
be
esta
blis
hed
is _
_(2)
____
.
4.
The
dist
ract
er a
naly
sis
(onl
y) c
onta
ins
a ty
po; t
he d
istra
cter
an
alys
is re
fers
to L
T-46
0 be
ing
out-o
f-tol
eran
ce e
ven
thou
gh
LT-4
61 is
out
-of-t
oler
ance
.
Q
# 1.
LO
K
(F/H
)
2.
LOD
(1
-5)
3. P
sych
omet
ric F
law
s 4.
Job
Con
tent
Fla
ws
5. O
ther
6.
S
ourc
e B
/M/N
7.
Sta
tus
U/E
/S
8.
Exp
lana
tion
Ste
m
Focu
s C
ues
T/F
Cre
d.
Dis
t. P
artia
l Jo
b-Li
nk
Min
utia
#/
un
its
Bac
k-w
ard
Q=
K/A
S
RO
O
nly
92
H
2 x
x
N
E/U
T2
G2
072
(AR
M –
kno
wle
dge
of E
OP
bas
es)
G2.
4.18
1.
The
oper
atio
nal v
alid
ity o
f all
radi
atio
n al
arm
s be
ing
clea
r afte
r un
cont
rolle
d de
pres
suriz
atio
n of
all
SG
s, c
oncu
rren
t with
a
SG
TR, i
s qu
estio
nabl
e. W
e ne
ed to
see
this
on
the
sim
ulat
or
and
disc
uss.
2.
Cre
d D
ist:
The
pla
usib
ility
of t
he 2
nd p
art o
f Cho
ices
B/D
(EO
P-
4.0
entry
not
requ
ired
with
SG
TR) i
s qu
estio
nabl
e be
caus
e of
th
e w
ordi
ng o
f the
2nd
fill-
in-th
e-bl
ank
stat
emen
t. T
o ea
sily
re
med
y, s
ugge
st in
clud
ing
a Ti
me
0325
bul
let t
hat s
tate
s:
“Che
mis
try s
ampl
es o
f SG
sec
onda
ry s
ides
has
NO
T be
en
com
plet
ed.”,
and
revi
sing
the
2nd fi
ll-in
-the-
blan
k st
atem
ent a
s:
“Exi
ting
EO
P-3
.1 a
t Ste
p 7,
and
tran
sfer
ring
to E
OP
-4.0
, E-3
S
TEA
M G
EN
ER
ATO
R T
UB
E R
UP
TUR
E, _
_(2)
__ re
quire
d.”
(is v
s is
NO
T)
3.
Cre
d D
ist:
The
pla
usib
ility
of t
he 1
st p
art o
f Cho
ices
C/D
(EO
P
base
s fo
r Ste
p 7
deci
sion
is “e
xpec
tatio
ns”)
is q
uest
iona
ble
beca
use
thes
e C
hoic
es c
onta
in th
e ph
rase
“tha
t are
exp
ecte
d”
(vs.
just
say
ing
afte
r the
reac
tor t
rip).
To
easi
ly re
med
y,
sugg
est r
evis
ing
the
1st fi
ll-in
-the-
blan
k st
atem
ent,
and
Cho
ices
C
/D, a
s:
In a
ccor
danc
e w
ith th
e ba
ses
for E
OP
-3.1
, Ste
p 7,
“nor
mal
” m
eans
the
valu
e of
a p
roce
ssed
par
amet
er _
__(1
)___
.
(dur
ing
rout
ine
plan
t ope
ratio
ns v
s. a
fter t
he re
acto
r trip
)
4.
Ste
m F
ocus
: Th
e 1st
fill-
in-th
e-bl
ank
stat
emen
t phr
ase
“as
it ap
plie
s to
the
RM
=G19
B ra
diat
ion
mon
itor r
eadi
ngs
chec
ked
in
step
7” c
an b
e sh
orte
ned,
as
in C
omm
ent #
3 su
gges
tion.
Q
# 1.
LO
K
(F/H
)
2.
LOD
(1
-5)
3. P
sych
omet
ric F
law
s 4.
Job
Con
tent
Fla
ws
5. O
ther
6.
S
ourc
e B
/M/N
7.
Sta
tus
U/E
/S
8.
Exp
lana
tion
Ste
m
Focu
s C
ues
T/F
Cre
d.
Dis
t. P
artia
l Jo
b-Li
nk
Min
utia
#/
un
its
Bac
k-w
ard
Q=
K/A
S
RO
O
nly
93
H
2 x
x
x x
N
E/U
T2
G2
086
(Fire
Pro
t – p
redi
ct lo
w h
dr p
ress
, use
pro
cedu
res)
A2.
02
1.
Q=K
/A a
nd/o
r SR
O-o
nly:
The
ent
ire K
/A m
ust b
e hi
t at t
he
SR
O-le
vel;
the
2nd p
ortio
n of
the
ques
tion,
whi
ch te
sts
the
SR
O
appl
ican
ts’ a
bilit
y to
cla
ssify
an
emer
genc
y, h
as n
othi
ng to
do
with
the
low
FP
hea
der p
ress
ure
K/A
topi
c.
The
1st p
art o
f the
qu
estio
n ca
n be
ans
wer
ed w
ith R
O k
now
ledg
e th
at th
e el
ectri
c-dr
iven
fire
pum
p lo
st p
ower
, and
sta
rt of
alte
rnat
e fir
e pu
mps
is
requ
ired
to m
aint
ain
head
er p
ress
ure.
The
SR
O a
spec
t for
this
K/A
cou
ld b
e sa
tisfie
d by
test
ing
fire
prot
ectio
n pr
ogra
m a
dmin
istra
tive
requ
irem
ents
, suc
h as
co
mpe
nsat
ory
actio
ns a
ssoc
iate
d w
ith d
egra
ded
or in
oper
able
FP
hea
ders
, spr
inkl
er s
yste
ms,
etc
. (S
ee E
S-4
01, A
ttach
men
t 2,
Sec
tion
II.A
(pag
e 19
of 5
2) fo
r exa
mpl
es o
f Con
ditio
ns a
nd
Lim
itatio
ns in
the
Faci
lity
Lice
nse.
2.
Par
tial:
Is th
e fir
e on
the
IB-4
27 ‘
elev
atio
n th
e ca
use
of th
e fu
el
oil l
ine
dam
age?
If n
ot, t
hen
the
SA
.9.1
Ale
rt cl
assi
ficat
ion
crite
ria m
ay n
ot b
e m
et, t
hat i
s, n
o co
rrec
t ans
wer
. E
nsur
e th
e op
erat
iona
l val
idity
of t
he IB
-427
ele
vatio
n fir
e in
con
text
of E
DG
fu
el o
il lin
e da
mag
e.
3.
Ste
m F
ocus
: Th
e ph
rase
“be
able
to” s
houl
d be
inse
rted
to th
e Ti
me
0705
bul
let a
s:
“A F
ire B
rigad
e m
embe
r is
resp
ondi
ng a
nd re
porte
d th
at s
he
shou
ld b
e ab
le to
ext
ingu
ish
the
fire
with
in th
e ne
xt fi
ve
min
utes
.”
94
F 2
x
x
M
U
S
AM
PLE
QU
ES
TIO
N R
EC
EIV
ED
12-
19-1
7
1.
Q=K
/A:
The
prop
osed
test
item
doe
s no
t tes
t tem
pora
ry
man
agem
ent d
irect
ives
.
2.
SR
O-o
nly:
The
cor
rect
ans
wer
can
be
dete
rmin
ed u
sing
RO
kn
owle
dge
of “w
ho” h
as re
spon
sibi
lity
for t
he o
vera
ll si
te v
s “w
ho” h
as re
spon
sibi
lity
for t
he u
nit.
The
SM
che
cklis
t inc
lude
s si
te s
ecur
ity k
eys
(ove
rall
site
) whe
reas
CR
S c
heck
list i
nclu
des
Bis
tabl
e-S
I and
SP
DS
dis
play
s (u
nit).
3.
The
ques
tion
is li
sted
as
“mod
ified
” how
ever
, it d
oes
not m
eet
the
sign
ifica
ntly
mod
ified
crit
eria
in E
S-4
01 (p
age
9 of
52)
be
caus
e on
e pe
rtine
nt c
ondi
tion
in th
e st
em h
as n
ot b
een
chan
ged
from
the
orig
inal
ver
sion
.
4.
Ste
m F
ocus
: Th
e ac
rony
ms
shou
ld b
e sp
elle
d ou
t.
Q
# 1.
LO
K
(F/H
)
2.
LOD
(1
-5)
3. P
sych
omet
ric F
law
s 4.
Job
Con
tent
Fla
ws
5. O
ther
6.
S
ourc
e B
/M/N
7.
Sta
tus
U/E
/S
8.
Exp
lana
tion
Ste
m
Focu
s C
ues
T/F
Cre
d.
Dis
t. P
artia
l Jo
b-Li
nk
Min
utia
#/
un
its
Bac
k-w
ard
Q=
K/A
S
RO
O
nly
94
F 3
x x
N
E
T3
G2.
1.15
(Kno
wle
dge
adm
in re
q’ts
for t
empo
rary
mgm
t. di
rect
ives
)
The
sam
ple
ques
tion
(abo
ve) w
as re
plac
ed w
ith a
new
test
item
; ho
wev
er, t
he fo
llow
ing
flaw
(s) e
xist
(s):
1.
Cue
: Th
e 2nd
col
umn
of in
form
atio
n (ty
pe o
f NR
C li
cens
e) is
not
ne
cess
ary
to e
licit
the
corr
ect r
espo
nse.
2.
Ste
m F
ocus
: Th
e ph
rase
“..to
ack
now
ledg
e re
ceip
t” in
the
stem
qu
estio
n is
not
nec
essa
ry.
3.
Ste
m F
ocus
: B
ased
on
Com
men
t #1,
sug
gest
add
ing
the
wor
d “li
cens
ed” b
efor
e th
e w
ord
“wat
ch s
tand
ers”
in th
e st
em
ques
tion.
95
x 2
x x
x
B
U
T3
G2.
1.40
(kno
wle
dge
of re
fuel
ing
adm
in re
quire
men
ts)
1.
Cre
d D
ist:
The
1st p
art o
f Cho
ices
C/D
(use
of T
S-1
doe
sn’t
requ
ire S
RO
con
curr
ence
) is
not p
laus
ible
bec
ause
a N
RC
lic
ense
d S
RO
is a
lway
s re
quire
d to
be
invo
lved
with
cor
e al
tera
tions
.
Not
e: T
he 1
st p
art o
f the
test
item
test
s th
e K
/A to
pic.
2.
Cue
: Th
e te
rm “M
aste
r Ove
rload
” in
the
2nd fi
ll-in
-the-
blan
k st
atem
ent i
s no
t nec
essa
ry to
elic
it th
e co
rrec
t res
pons
e.
3.
Ste
m F
ocus
: Th
ere
are
mul
tiple
opp
ortu
nitie
s to
min
imiz
e th
e re
adin
g bu
rden
for t
his
test
item
, whi
ch m
ay in
clud
e el
imin
atin
g al
l the
info
rmat
ion
abov
e th
e st
em q
uest
ion.
4.
LOK
: Th
e pr
opos
ed te
st it
em te
sts
the
follo
win
g tw
o m
emor
y (lo
wer
cog
) asp
ects
; the
que
stio
n is
mar
ked
as h
ighe
r cog
:
W
hose
aut
horiz
atio
n an
d co
ncur
renc
e is
requ
ired
to u
se
the
TS-1
Ove
rload
Byp
ass
Sw
itch?
W
ill th
e M
aste
r Ove
rload
stil
l pro
vide
ove
rload
pro
tect
ion
whe
n TS
-1 is
in th
e B
YPA
SS
pos
ition
?
Q
# 1.
LO
K
(F/H
)
2.
LOD
(1
-5)
3. P
sych
omet
ric F
law
s 4.
Job
Con
tent
Fla
ws
5. O
ther
6.
S
ourc
e B
/M/N
7.
Sta
tus
U/E
/S
8.
Exp
lana
tion
Ste
m
Focu
s C
ues
T/F
Cre
d.
Dis
t. P
artia
l Jo
b-Li
nk
Min
utia
#/
un
its
Bac
k-w
ard
Q=
K/A
S
RO
O
nly
96
H
2 x
x
N
E/U
T3
G2.
2.23
(abi
lity
to tr
ack
LCO
s)
1.
Cre
d D
ist:
The
1st p
art o
f Cho
ices
A/B
(RO
upd
ates
the
EO
OS
C
ompu
ter P
rogr
am) i
s no
t pla
usib
le b
ecau
se th
e O
ATC
is
resp
onsi
ble
for m
onito
ring
the
reac
tor,
and
not g
ettin
g ca
ught
up
in p
erip
hera
l act
iviti
es, a
nd u
pdat
ing
the
EO
OS
Com
pute
r P
rogr
am to
ens
ure
actu
al e
quip
men
t TS
sta
tus
is a
lway
s S
RO
fu
nctio
n.
This
can
eas
ily b
e re
med
ied
by re
mov
ing
the
EO
OS
pie
ce (b
ut
keep
BIS
I), a
nd c
hang
e “R
eact
or O
pera
tor”
to “B
alan
ce o
f Pla
nt
Ope
rato
r.”
2.
Ste
m F
ocus
: Th
e te
rm “p
roce
dura
l too
l” is
sub
ject
ive;
sug
gest
re
-wor
king
the
2nd p
art o
f the
test
item
to te
st w
hich
Atta
chm
ent
is re
quire
d to
be
upda
ted
afte
r the
pum
p is
retu
rned
to s
ervi
ce.
3.
Ste
m F
ocus
: Th
e 3rd
bul
let i
s va
gue,
that
is, “
bein
g re
turn
ed to
an
OP
ER
AB
LE s
tatu
s”; t
he b
ulle
t sho
uld
say
“has
just
bee
n re
turn
ed to
an
OP
ER
AB
LE s
tatu
s.”
The
reas
on (a
fter c
orre
ctiv
e m
aint
enan
ce) i
s no
t nec
essa
ry.
97
F 2
x
x
M
E
T3
G2.
2.5
(kno
wle
dge
of p
roce
ss fo
r des
ign/
oper
atin
g ch
ange
s)
1.
Ste
m F
ocus
and
/or P
artia
l: T
he re
adin
g bu
rden
and
cha
nce
of
an a
pplic
ant c
onte
ndin
g a
parti
ally
cor
rect
ans
wer
, or n
o co
rrec
t an
swer
, can
be
min
imiz
ed b
y re
-wor
ding
the
ques
tion
as:
WO
OTF
com
plet
es b
oth
stat
emen
ts in
acc
orda
nce
with
SA
P-
148,
TE
MP
OR
AR
Y B
YP
AS
S, J
UM
PE
R, A
ND
LIF
TED
LE
AD
C
ON
TRO
L?
All
Byp
ass
Aut
horiz
atio
n R
eque
sts
(BA
Rs)
sho
uld
be re
stor
ed to
no
rmal
with
in _
_(1)
___.
The
__(2
)___
is re
spon
sibl
e fo
r app
rovi
ng a
ll B
AR
s th
at w
ill
exce
ed th
is ti
me
limit.
Q
# 1.
LO
K
(F/H
)
2.
LOD
(1
-5)
3. P
sych
omet
ric F
law
s 4.
Job
Con
tent
Fla
ws
5. O
ther
6.
S
ourc
e B
/M/N
7.
Sta
tus
U/E
/S
8.
Exp
lana
tion
Ste
m
Focu
s C
ues
T/F
Cre
d.
Dis
t. P
artia
l Jo
b-Li
nk
Min
utia
#/
un
its
Bac
k-w
ard
Q=
K/A
S
RO
O
nly
98
x 2
x x
x
M
E
T3
G2.
3.4
(Kno
wle
dge
of ra
d ex
posu
re li
mits
und
er n
orm
al/e
mer
g)
1.
Par
tial:
The
4th s
tem
bul
let (
and
its s
ub-b
ulle
ts) c
an li
kely
resu
lt in
a p
ost-e
xam
con
tent
ion
that
ther
e is
no
corr
ect a
nsw
er to
the
1st p
art o
f the
que
stio
n.
It
is n
ot c
lear
whe
ther
nor
mal
10C
FR20
exp
osur
e lim
its
wer
e su
spen
ded
(See
EP
P-0
20, I
tem
s 4.
a an
d 4.
b), a
nd
the
stem
que
stio
n do
esn’
t say
in a
ccor
danc
e w
ith
Atta
chm
ent I
II, G
uida
nce
on D
ose
Lim
its F
or W
orke
rs
Per
form
ing
Em
erge
ncy
Ser
vice
s. T
here
fore
, Cho
ice
A is
al
so c
orre
ct s
ince
5 re
m is
the
10C
FR20
ann
ual
occu
patio
nal e
xpos
ure
limit.
A
LO
CA
out
side
of c
onta
inm
ent e
xist
s an
d th
e A
O is
ne
eded
to o
pera
te p
lant
equ
ipm
ent;
this
doe
s no
t elim
inat
e th
e as
sum
ptio
n th
at th
e op
erat
ion
of th
e pl
ant e
quip
men
t w
ould
pre
vent
a c
ore
mel
t and
is n
eede
d to
sav
e va
luab
le
equi
pmen
t.
Th
e su
b-bu
llets
are
mis
sing
cla
rific
atio
n th
at th
e A
O a
ctio
n is
not
nee
ded
to s
ave
a lif
e; th
eref
ore,
it is
con
ceiv
able
that
op
erat
ing
the
plan
t equ
ipm
ent m
ust b
e fo
r life
savi
ng
effo
rts.
2.
Cue
: Th
e 3rd
bul
let (
SM
relie
ved
of d
utie
s af
ter T
SC
man
ned
and
activ
ated
) is
not n
eede
d to
elic
it th
e co
rrec
t res
pons
e.
3.
Ste
m F
ocus
: Th
e la
st (6
th) s
tem
bul
let i
s no
t nec
essa
ry; s
ugge
st
mov
ing
proc
edur
e nu
mbe
r/titl
e in
to th
e st
eam
que
stio
n.
4.
LOK
: Th
is te
st it
em m
ay b
e hi
gher
cog
; let
’s d
iscu
ss.
Q
# 1.
LO
K
(F/H
)
2.
LOD
(1
-5)
3. P
sych
omet
ric F
law
s 4.
Job
Con
tent
Fla
ws
5. O
ther
6.
S
ourc
e B
/M/N
7.
Sta
tus
U/E
/S
8.
Exp
lana
tion
Ste
m
Focu
s C
ues
T/F
Cre
d.
Dis
t. P
artia
l Jo
b-Li
nk
Min
utia
#/
un
its
Bac
k-w
ard
Q=
K/A
S
RO
O
nly
99
H
2 x
x
x x
N
E
T3 G
2.4.
26 (k
now
ledg
e of
fire
brig
ade
& p
orta
ble
fire
equi
p us
e)
1.
Cue
: Th
e on
ly C
hoic
e th
at th
e bo
lded
und
erlin
ed s
tate
men
t w
ould
eve
r app
ly to
is a
lso
the
corr
ect a
nsw
er.
2.
Ste
m F
ocus
: Th
e w
ay th
e 5th
bul
let A
O in
form
atio
n is
pre
sent
ed
is c
onfu
sing
; it m
ay b
e cl
eare
r to
the
appl
ican
ts a
s:
Fo
ur fu
lly q
ualif
ied
AO
s re
porte
d fo
r the
on-
com
ing
shift
o
One
of t
he fo
ur A
Os
is a
lso
a Fi
re B
rigad
e O
pera
tions
A
dvis
or
o
One
of t
he fo
ur A
Os
is a
lso
a Fi
re B
rigad
e M
embe
r
3.
Cre
d D
ist:
The
pla
usib
ility
of C
hoic
e A
can
be
enha
nced
(b
ecau
se C
hoic
e A
impl
ies
no C
R w
ill b
e w
ritte
n, e
tc.)
by re
-w
ordi
ng it
as:
A.
No
addi
tiona
l shi
ft m
anni
ng a
ctio
ns a
re re
quire
d; m
inim
um
crew
com
posi
tion
requ
irem
ents
are
met
.
4.
Ste
m F
ocus
: C
hoic
es B
and
C s
houl
d be
cla
rifie
d w
ith th
e w
ord
“onl
y” a
s:
B.
The
shift
man
ager
mus
t onl
y fil
l a v
acan
t AO
wat
ch p
ositi
on
with
in a
max
imum
of 2
hou
rs.
C.
The
shift
man
ager
mus
t onl
y fil
l a v
acan
t Fire
Brig
ade
posi
tion
with
in a
max
imum
of 2
hou
rs.
5.
Par
tial:
The
ste
m q
uest
ion
shou
ld b
e re
vise
d to
say
:
“WO
OTF
is th
e m
inim
um re
quire
d ac
tion
that
mus
t be
take
n, if
an
y, to
ens
ure
AO
and
Fire
Brig
ade
Shi
ft M
anni
ng re
quire
men
ts
are
met
IAW
OA
P-1
00.6
?”
Not
e: T
he S
RO
kno
wle
dge
bein
g te
sted
is T
ech
Spe
c Ta
ble
6.2-
1,
incl
udin
g w
heth
er th
e 2
hour
allo
wan
ce is
acc
epta
ble
for t
he
situ
atio
n.
Q
# 1.
LO
K
(F/H
)
2.
LOD
(1
-5)
3. P
sych
omet
ric F
law
s 4.
Job
Con
tent
Fla
ws
5. O
ther
6.
S
ourc
e B
/M/N
7.
Sta
tus
U/E
/S
8.
Exp
lana
tion
Ste
m
Focu
s C
ues
T/F
Cre
d.
Dis
t. P
artia
l Jo
b-Li
nk
Min
utia
#/
un
its
Bac
k-w
ard
Q=
K/A
S
RO
O
nly
100
H
1.5
x
M
E
/U
T3 G
2.4.
28 (E
mer
g P
roce
dure
s re
latin
g to
sab
otag
e)
1.
LOD
=1.5
: Th
e pr
opos
ed te
st it
em w
ill p
rovi
de n
o di
scrim
inat
ory
valu
e on
the
exam
; the
pre
mis
e of
the
ques
tion
is te
stin
g a
phys
ical
ly “h
ostil
e”, a
nd th
e on
ly th
ing
bein
g te
sted
is th
e di
ffere
nce
betw
een
the
owne
r-co
ntro
lled
vs p
rote
cted
are
a,
whi
ch is
GE
T kn
owle
dge.
O
ne id
ea is
to te
st th
e ap
plic
ants
’ kno
wle
dge
of th
e E
-pla
n B
ases
for t
he d
efin
ition
of a
“Hos
tile
Act
ion.
” Fo
r exa
mpl
e,
the
prop
osed
test
item
cou
ld b
e m
odifi
ed to
onl
y in
clud
e st
em in
form
atio
n re
late
d to
equ
ipm
ent s
abot
age
(with
out t
he
host
ile in
trude
r/pro
test
er b
ulle
ts).
A
noth
er id
ea m
ay b
e to
test
the
VC
S a
dmin
istra
tive
requ
irem
ent(s
) for
dis
cove
ring
plan
t equ
ipm
ent t
hat m
ay
have
bee
n sa
bota
ged.
For
exa
mpl
e, V
CS
adm
inis
trativ
e re
quire
men
ts fo
r seq
uest
erin
g th
e eq
uipm
ent a
nd/o
r NR
C
notif
icat
ion
requ
irem
ents
.
2.
Ste
m F
ocus
: Th
e w
ord
“pro
test
er”,
“intru
der”
, “pe
rson
”, an
d “h
e”
are
used
inte
rcha
ngea
bly
in th
e Ti
me
1230
and
140
0 ev
ents
; su
gges
t not
usi
ng th
e w
ord
“he”
bec
ause
it m
ay b
e co
nfus
ing
whe
ther
this
mea
ns th
e gu
ard
or th
e in
trude
r. A
lso
sugg
est
usin
g th
e w
ord
“pro
test
er” i
nste
ad o
f “in
trude
r.”