rev a. magnetic level gauge with level transmitter datasheet.pdf

Upload: nguyenquitrong

Post on 06-Jan-2016

23 views

Category:

Documents


0 download

TRANSCRIPT

  • PETROVIETNAM LOW PRESSURE GAS DISTRIBUTION

    JOINT STOCK COMPANY

    PROJECT TIEN HAI THAI BINH LOW PRESSURE GAS DISTRIBUTION

    PIPELINE SYSTEM

    PHASE DEHYDRATION

    MAGNETIC LEVEL GAUGE WITH LEVEL TRANSMITTER

    A 12/12/2014 Issued for Review TVN LDB NHC

    Prepared by Checked by Approved by Checked by Approved by

    Rev Date Description Alpha-ECC PVGAS D

    Contractor:

    ALPHA ECC

    Contractors Document Number:

    KTA.TB-PAC03-J13-005

    Total pages: 5

    (Incl. this page)

  • CUSTOMER : PVGAS D

    LOCATION : VIETNAM

    AREA : BLOCK 102 & 106 - PHASE 1 PROJECT No.

    PROJECT : TB-HR LPGD PIPELINE SYSTEM SHEET

    1 Tag No.

    2 Service

    3 P&ID No.

    4 Line/Vessel No.

    5 Hazardous Area Classification

    6 Quantity

    7

    8 Fluid

    9 Phase

    10 Operating pressure Barg

    11 Operating temperature C

    12 Design pressure Barg

    13 Design Temperature C

    14 Operating differential Pressure mBar

    15 Liquid (mixture) density Kg/m3

    16 Body or Chamber Material

    Magnetic Follower/Float Material

    18 Flange Material

    Flange Rating

    20 Process Connection Type

    Conn Size & Location : Upper

    22 Conn Size & Location : Lower

    Vent / Drain Conn. Type & Size

    24 Visible Length

    Center To Center Distance

    26 Indicator Type

    Indicator Scale

    28 Indicator Scale Material

    Manufacturer

    31 Model No.

    Service

    33 Function

    Range

    35 Output

    Supply Voltage

    37 Accuracy

    Output Action

    39 Mounting

    41

    Conduit Connection

    43 Ex Certification

    Mounting

    45 Drain and Vent Valves:

    NACE Compliant

    NOTES : 1. Insulation support/clip shall be provided by Vendor for insulation installed by Purchaser.

    2. Refer to P&ID

    3. Transmitter shall be supplied with 316 SS, Ex i, ATEX certified plugs for all spare cable entries

    4. The rolling magnet type of indication with red and yellow follower.

    5 Transmitter enclosure/ casing/ junction box shall be epoxy-coated low copper aluminium.

    ITEM/TAG No. LZT-0133

    DATA SHEET No. KTA.TB-PAC03-J13-001.02

    1 OF 4

    INSTRUMENT DATA SHEETMAGNETIC LEVEL GAUGE WITH LEVEL TRANSMITTER

    ZONE 2 , GROUP IIA, T3

    1 (One)

    PR

    OC

    ES

    S D

    ET

    AIL

    S

    TEG

    Liquid

    3.9

    70

    10

    100

    GE

    NE

    RA

    L

    LG-0133/LZT-0133

    Flash Vessel

    KTA.TB-PAC03-M07-003

    V-101

    N/A

    1079

    ASME 150# RF WN

    Flanged

    FL

    OA

    T M

    AT

    ER

    IAL

    316SS

    17 316SS

    316SS

    19

    23 Flanged 150# RF, DN 20

    21 DN50, Side

    DN50, Side

    IND

    ICA

    TO

    R 1500 mm

    25 1500 mm

    Magnetic flap

    27 Magnetic flap

    316 SS

    Magnetic Level Gauge and Level Transmitter

    Indicate/Transmit

    34 0-100%

    4-20 mA (2-wire), HART comm. Protocol.

    Contacts : No. Form

    36 24 V DC

    0.1% of full span

    38 Increase

    Integral Low

    40 Enclosure: Material Class Aluminium (Note 5) IP65

    42 M20x1.5

    EEx:ia IIB T4

    OT

    HE

    R

    44 Direct Mounted (Bottom)

    3/4" 150# WNRF FLAGNE

    46 N/A

    TR

    AN

    SM

    ITT

    ER

    29 VTA

    VTA

    32

  • CUSTOMER : PVGAS D

    LOCATION : VIETNAM

    AREA : BLOCK 102 & 106 - PHASE 1 PROJECT No.

    PROJECT : TB-HR LPGD PIPELINE SYSTEM SHEET

    1 Tag No.

    2 Service

    3 P&ID No.

    4 Line/Vessel No.

    5 Hazardous Area Classification

    6 Quantity

    7

    8 Fluid

    9 Phase

    10 Operating pressure Barg

    11 Operating temperature C

    12 Design pressure Barg

    13 Design Temperature C

    14 Operating differential Pressure mBar

    15 Liquid (mixture) density Kg/m3

    17 Body or Chamber Material

    Magnetic Follower/Float Material

    19 Flange Material

    Flange Rating

    21 Process Connection Type

    Conn Size & Location : Upper

    23 Conn Size & Location : Lower

    Vent / Drain Conn. Type & Size

    25 Visible Length

    Center To Center Distance

    27 Indicator Type

    Indicator Scale

    29 Indicator Scale Material

    Manufacturer

    31 Model No.

    Service

    33 Function

    Range

    35 Output

    Supply Voltage

    37 Accuracy

    Output Action

    39 Mounting

    41

    Conduit Connection

    43 Ex Certification

    Mounting

    45 Drain and Vent Valves:

    NACE Compliant

    NOTES : 1. Insulation support/clip shall be provided by Vendor for insulation installed by Purchaser.

    2. Refer to P&ID

    3. Transmitter shall be supplied with 316 SS, Ex i, ATEX certified plugs for all spare cable entries

    4. The rolling magnet type of indication with red and yellow follower.

    5 Transmitter enclosure/ casing/ junction box shall be epoxy-coated low copper aluminium.

    ITEM/TAG No. LZT-0142

    DATA SHEET No. KTA.TB-PAC03-J13-005.02

    2 OF 4

    INSTRUMENT DATA SHEETMAGNETIC LEVEL GAUGE WITH LEVEL TRANSMITTER

    ZONE 2 , GROUP IIA, T3

    1 (One)

    PR

    OC

    ES

    S D

    ET

    AIL

    S

    TEG

    Liquid

    0.20

    43-93.4

    7.5

    100

    GE

    NE

    RA

    L

    LZT-0142

    Glycol Surge Drum

    KTA.TB-PAC03-M07-004

    V-103

    N/A

    1066.1

    FL

    OA

    T M

    AT

    ER

    IAL

    316SS

    18 316SS

    316SS

    20 ASME 150# RF WN

    Flanged

    22 DN50, Side

    DN50, Side

    24 Flanged 150# RF, DN 20

    0.1% of full span

    28 Magnetic flap

    316 SS

    TR

    AN

    SM

    ITT

    ER

    30 VTA

    VTA

    32 Magnetic Level Gauge and Level Transmitter

    Indicate/Transmit

    IND

    ICA

    TO

    R 1900 mm

    26 1900 mm

    Magnetic flap

    34 0-100%

    4-20 mA (2-wire), HART comm. Protocol.

    36 24 V DC

    38 Increase

    Integral Low

    40 Enclosure: Material Class Aluminium (Note 5) IP65

    Contacts : No. Form

    42 M20x1.5

    EEx:ia IIB T4

    OT

    HE

    R

    44 Direct Mounted (Bottom)

    3/4" 150# WNRF FLAGNE

    46 N/A

  • CUSTOMER : PVGAS D

    LOCATION : VIETNAM

    AREA : BLOCK 102 & 106 - PHASE 1 PROJECT No.

    PROJECT : TB-HR LPGD PIPELINE SYSTEM SHEET

    1 Tag No.

    2 Service

    3 P&ID No.

    4 Line/Vessel No.

    5 Hazardous Area Classification

    6 Quantity

    7

    8 Fluid

    9 Phase

    10 Operating pressure Barg

    11 Operating temperature C

    12 Design pressure Barg

    13 Design Temperature C

    14 Operating differential Pressure mBar

    15 Liquid (mixture) density Kg/m3

    17 Body or Chamber Material

    Magnetic Follower/Float Material

    19 Flange Material

    Flange Rating

    21 Process Connection Type

    Conn Size & Location : Upper

    23 Conn Size & Location : Lower

    Vent / Drain Conn. Type & Size

    25 Visible Length

    Center To Center Distance

    27 Indicator Type

    Indicator Scale

    29 Indicator Scale Material

    Manufacturer

    31 Model No.

    Service

    33 Function

    Range

    35 Output

    Supply Voltage

    37 Accuracy

    Output Action

    39 Mounting

    41

    Conduit Connection

    43 Ex Certification

    Mounting

    45 Drain and Vent Valves:

    NACE Compliant

    NOTES : 1. Insulation support/clip shall be provided by Vendor for insulation installed by Purchaser.

    2. Refer to P&ID

    3. Transmitter shall be supplied with 316 SS, Ex i, ATEX certified plugs for all spare cable entries

    4. The rolling magnet type of indication with red and yellow follower.

    5 Transmitter enclosure/ casing/ junction box shall be epoxy-coated low copper aluminium.

    ITEM/TAG No. LZT-0172

    DATA SHEET No. KTA.TB-PAC03-J13-005.02

    3 OF 4

    INSTRUMENT DATA SHEETMAGNETIC LEVEL GAUGE WITH LEVEL TRANSMITTER

    ZONE 2 , GROUP IIA, T3

    1 (One)

    PR

    OC

    ES

    S D

    ET

    AIL

    S

    Water

    Liquid

    0.30

    37

    7.5

    100

    GE

    NE

    RA

    L

    LZT-0172

    Flash Vessel

    KTA.TB-PAC03-M07-007

    V-104

    N/A

    993.4

    FL

    OA

    T M

    AT

    ER

    IAL

    316SS

    18 316SS

    316SS

    20 ASME 150# RF WN

    Flanged

    22 DN50, Side

    DN50, Side

    24 Flanged 150# RF, DN 20

    0.1% of full span

    28 Graduated in%

    316 SS

    TR

    AN

    SM

    ITT

    ER

    30 VTA

    VTA

    32 Magnetic Level Gauge and Level Transmitter

    Indicate/Transmit

    IND

    ICA

    TO

    R 800 mm

    26 800 mm

    Magnetic flap

    34 0-100%

    4-20 mA (2-wire), HART comm. Protocol.

    36 24 V DC

    38 Increase

    Integral Low

    40 Enclosure: Material Class Aluminium (Note 5) IP65

    Contacts : No. Form

    42 M20x1.5

    EEx:ia IIB T4

    OT

    HE

    R

    44 Direct Mounted (Bottom)

    3/4" 150# WNRF FLAGNE

    46 N/A

  • CUSTOMER : PVGAS D ITEM/TAG No.

    LOCATION : VIETNAM DATA SHEET No. KTA.TB-PAC03-J13-005.02

    AREA : BLOCK 102 & 106 - PHASE 1 PROJECT No. AL-3098

    PROJECT : TBHR GAS DISTRIBUTION AND GATHERING SHEET 4 OF 4

    GENERAL NOTES

    1. Documentation Required:

    Hazardous Area Certificate - ATEX certification

    Ingress Protection Certificate

    Hydrotest Certificate

    Calibration Certificate

    Material Certificate, ISO-EN 10204, Type 3.1 (B) for pressure retaining parts.

    Installation & Commissioning spare Parts List and 2 years Operational Spares List

    Compliance/ Conformance Certificate

    General Arrangement drawing with complete Model Numbers, Dimension and Hookup details

    2. All instruments shall be provided with a SS 316 name plate with tag no. pernamently inscribed

    3 Level transmitters and accessories shall be able to sustain process design pressure, temperature and service fluid.

    4 Level transmitters and accessories should meet the following specifications:

    Specification for instrumentation KTA.TB-PAC03-M65-007

    5 Elastomer used in the instrument / accessories are compatible with the service fluid specified at design conditions.

    6 All tube fittings shall be SS316, of Swagelok make, imperial size, double compression type.

    7 Field bus based transmitter/ devices must satisfy the requirements of the field bus registration laboratory with applicable checkmark of foundation field bus.

    8 The field bus instruments in hazardous area shall be certified as per entity concept or shall be FISCO approved.

    9 Internal software shall be configured by the vendor including the following information such as serial number, Device Tag (Tag Number) and Process description.

    10 Bolts/nut ASTM A193 Gr.B7/A194-2H with xylan flourocarbon coated

    INSTRUMENT DATA SHEET

    MAGNETIC LEVEL GAUGE WITH LEVEL TRANSMITTER- NOTES

    VALVES SPECIFICATIONATION SHEETVALVES SPECIFICATIONATION SHEETVALVES SPECIFICATIONATION SHEETVALVES SPECIFICATIONATION SHEET

  • CUSTOMER : PVGAS D ITEM/TAG No. LIT-0111

    LOCATION : VIETNAM DATA SHEET No. KTA.TB-PAC03-J13-005.02

    AREA : BLOCK 102 & 106 - PHASE 1 PROJECT No. AL-3098

    PROJECT : TB-HR LPGD PIPELINE SYSTEM SHEET 1 OF 10

    1 Tag No.

    2 Service

    3 P&ID No.

    4 Line/Vessel No.

    5 Hazardous Area Classification

    6 Quantity

    7

    8 Fluid

    9 Phase

    10 Operating pressure Barg

    11 Operating temperature C

    12 Design pressure Barg

    13 Design Temperature C

    14 Operating differential Pressure mBar

    15 Liquid (mixture) density Kg/m3

    16 Vapour density Kg/m3

    Body or Chamber Material

    Magnetic Follower/Float Material

    Flange Material

    Flange Rating

    Process Connection Type

    Conn Size & Location : Upper

    Conn Size & Location : Lower

    Vent / Drain Conn. Type & Size

    Visible Length

    Center To Center Distance

    Indicator Type

    Indicator Scale

    Indicator Scale Material

    31 Manufacturer

    32 Model No.

    33 Service

    34

    35

    36

    37 Supply Voltage

    38

    39 Output Action

    40

    41 Enclosure: Material

    30 Contacts : No.

    34 Conduit Connection

    35 Ex Certification

    36 Mounting

    37 Drain and Vent Valves:

    38 NACE Compliant

    39

    NOTES : 1. Insulation support/clip shall be provided by Vendor for insulation installed by Purchaser.

    2. Refer to P&ID

    3. Transmitter shall be supplied with 316 SS, Ex i, ATEX certified plugs for all spare cable entries

    4. The rolling magnet type of indication with red and yellow follower.

    5 Transmitter enclosure/ casing/ junction box shall be epoxy-coated low copper aluminium.

    Increase

    Integral Low

    M20x1.5

    EEx:ia IIB T4

    Aluminium (Note 5)

    Indicate/Transmit

    0-100%

    4-20 mA (2-wire), HART comm. Protocol.

    24 V DC

    0.1% of full span

    VTA

    VTA

    Magnetic Level Gauge and Level Transmitter

    316 SS

    316 SS

    316 SS

    ASME 600# RF WN

    Flanged

    DN50, Side

    DN50 Side

    Flanged 600# RF, DN 20

    40

    65

    N/A

    1093.5

    9.41

    OT

    HE

    R

    Direct Mounted (Bottom )

    3/4" 600# WNRF FLAGNE

    N/A

    INSTRUMENT DATA SHEETMAGNETIC LEVEL GAUGE WITH LEVEL TRANSMITTER

    GE

    NE

    RA

    LP

    RO

    CE

    SS

    DE

    TA

    ILS

    TR

    AN

    SM

    ITT

    ER

    TEG

    Liquid

    1 (One)

    ZONE 2, GROUP IIA, T3

    C-101

    KTA.TB-PAC03-M07-001

    Glycol Contactor C-101

    LG-0111/LIT-0111

    11.8 - 33.57

    17.3 - 42.3

    IP65

    26

    27

    Mounting

    Class

    Form

    Function

    Range

    Output

    Accuracy

    21

    22

    23

    24

    25

    FL

    OA

    T M

    AT

    ER

    IAL

    IND

    ICA

    TO

    R

    1320mm

    1320mm

    Magnetic flap

    Graduated in%

    316 SS

    Function

    28

    29

    30

    17

    18

    19

    20

    VALVES SPECIFICATIONVALVES SPECIFICATIONVALVES SPECIFICATIONVALVES SPECIFICATIONVALVES SPECIFICATIONVALVES SPECIFICATIONVALVES SPECIFICATIONVALVES SPECIFICATIONVALVES SPECIFICATIONVALVES SPECIFICATIONVALVES SPECIFICATIONVALVES SPECIFICATION

  • CUSTOMER : PVGAS D ITEM/TAG No. LIT-0114

    LOCATION : VIETNAM DATA SHEET No. KTA.TB-PAC03-J13-005.02

    AREA : BLOCK 102 & 106 - PHASE 1 PROJECT No. AL-3098

    PROJECT : TB-HR LPGD PIPELINE SYSTEM SHEET 2 OF 10

    1 Tag No.

    2 Service

    3 P&ID No.

    4 Line/Vessel No.

    5 Hazardous Area Classification

    6 Quantity

    7

    8 Fluid

    9 Phase

    10 Operating pressure Barg

    11 Operating temperature C

    12 Design pressure Barg

    13 Design Temperature C

    14 Operating differential Pressure mBar

    15 Liquid (mixture) density Kg/m3

    16 Vapour density Kg/m3

    17 Body or Chamber Material

    18 Magnetic Follower/Float Material

    19 Flange Material

    20 Flange Rating

    21 Process Connection Type

    22 Conn Size & Location : Upper

    23 Conn Size & Location : Lower

    24 Vent / Drain Conn. Type & Size

    25 Visible Length

    26 Center To Center Distance

    27 Indicator Type

    28 Indicator Scale

    29 Indicator Scale Material

    30

    31 Manufacturer

    32 Model No.

    33 Service

    34

    35

    36

    37 Supply Voltage

    38

    39 Output Action

    40

    41 Enclosure: Material

    42 Contacts : No.

    43 Conduit Connection

    44 Ex Certification

    45 Mounting

    46 Drain and Vent Valves:

    47 NACE Compliant

    48

    NOTES : 1. Insulation support/clip shall be provided by Vendor for insulation installed by Purchaser.

    2. Refer to P&ID

    3. Transmitter shall be supplied with 316 SS, Ex i, ATEX certified plugs for all spare cable entries

    4. The rolling magnet type of indication with red and yellow follower.

    5 Transmitter enclosure/ casing/ junction box shall be epoxy-coated low copper aluminium.

    INSTRUMENT DATA SHEETMAGNETIC LEVEL GAUGE WITH LEVEL TRANSMITTER

    GE

    NE

    RA

    L

    LG-0114/LIT-0114

    Glycol Contactor C-101

    KTA.TB-PAC03-M07-001

    C-101

    ZONE 2, GROUP IIA, T3

    1 (One)

    PR

    OC

    ES

    S D

    ET

    AIL

    S

    Hydrocarbon

    Liquid

    13.7

    34.6 - 36.4

    40

    65

    N/A

    716.1 - 994.9

    9.41

    316 SS

    316 SS

    TR

    AN

    SM

    ITT

    ER

    VTA

    VTA

    Magnetic Level Gauge and Level Transmitter

    Indicate/Transmit

    0-100%

    4-20 mA (2-wire), HART comm. Protocol.

    24 V DC

    EEx:ia IIB T4

    0.1% of full span

    Increase

    Integral Low

    IP65

    M20x1.5

    OT

    HE

    R

    Direct Mounted (Bottom / Top)

    3/4" 600# WNRF FLAGNEe

    N/A

    316 SS

    ASME 600# RF WN

    Flanged

    DN50, Side

    DN50 Side

    Flanged 600# RF, DN 20

    1000mm(Estimate)

    1000mm(Estimate)

    Magnetic flap

    Graduated in%

    316 SSIND

    ICA

    TO

    RF

    LO

    AT

    MA

    TE

    RIA

    L

    Function

    Range

    Output

    Accuracy

    Mounting

    Class

    Form

    Aluminium (Note 5)

    VALVES SPECIFICATIONVALVES SPECIFICATIONVALVES SPECIFICATIONVALVES SPECIFICATIONVALVES SPECIFICATIONVALVES SPECIFICATIONVALVES SPECIFICATIONVALVES SPECIFICATIONVALVES SPECIFICATIONVALVES SPECIFICATIONVALVES SPECIFICATIONVALVES SPECIFICATION

  • CUSTOMER : PVGAS D

    LOCATION : VIETNAM

    AREA : BLOCK 102 & 106 - PHASE 1 PROJECT No. AL-3098

    PROJECT : TB-HR LPGD PIPELINE SYSTEM SHEET

    1 Tag No.

    2 Service

    3 P&ID No.

    4 Line/Vessel No.

    5 Hazardous Area Classification

    6 Quantity

    8 Fluid

    9 Phase

    10 Operating pressure Barg

    11 Operating temperature C

    12 Design pressure Barg

    13 Design Temperature C

    14 Operating differential Pressure mBar

    15 Liquid (mixture) density Kg/m3

    16 Vapour density Kg/m3

    17 Body or Chamber Material

    18 Magnetic Follower/Float Material

    19 Flange Material

    20 Flange Rating

    21 Process Connection Type

    22 Conn Size & Location : Upper

    23 Conn Size & Location : Lower

    24 Vent / Drain Conn. Type & Size

    25 Visible Length

    26 Center To Center Distance

    27 Indicator Type

    28 Indicator Scale

    29 Indicator Scale Material

    30

    31 Manufacturer

    32 Model No.

    33 Service

    34

    35

    36

    37 Supply Voltage

    38

    39 Output Action

    40

    41 Enclosure: Material

    42 Contacts : No.

    43 Conduit Connection

    44 Ex Certification

    45 Mounting

    46 Drain and Vent Valves:

    47 NACE Compliant

    48

    NOTES : 1. Insulation support/clip shall be provided by Vendor for insulation installed by Purchaser.

    2. Refer to P&ID

    3. Transmitter shall be supplied with 316 SS, Ex i, ATEX certified plugs for all spare cable entries

    4. The rolling magnet type of indication with red and yellow follower.

    5 Transmitter enclosure/ casing/ junction box shall be epoxy-coated low copper aluminium.

    PR

    OC

    ES

    S D

    ET

    AIL

    S

    TEG

    Liquid

    11.8 - 33.57

    17.3 - 42.3

    40

    65

    N/A

    1093.5

    9.41

    Flanged 600# RF, DN 20

    TR

    AN

    SM

    ITT

    ER

    VTA

    VTA

    Magnetic Level Gauge and Level Transmitter

    Indicate/Transmit

    0-100%

    Class

    Form

    Aluminium (Note 5) IP65

    M20x1.5

    EEx:ia IIB T4

    Function

    Range

    Output

    ITEM/TAG No. LZT-0113

    DATA SHEET No. KTA.TB-PAC03-J13-005.02

    3 OF 10

    4-20 mA (2-wire), HART comm. Protocol.

    24 V DC

    INSTRUMENT DATA SHEETMAGNETIC LEVEL GAUGE WITH LEVEL TRANSMITTER

    GE

    NE

    RA

    L

    LG-0113/LZT-0113

    Glycol Contactor C-101

    KTA.TB-PAC03-M07-001

    C-101

    ZONE 2, GROUP IIA, T3

    1 (One)

    IND

    ICA

    TO

    RF

    LO

    AT

    MA

    TE

    RIA

    LO

    TH

    ER

    Direct Mounted (Bottom )

    3/4" 600# WNRF FLAGNE

    N/A

    316 SS

    ASME 600# RF WN

    Flanged

    DN50, Side

    DN50 Side

    316 SS

    316 SS

    Mounting

    1320mm

    1320mm

    Magnetic flap

    Graduated in%

    316 SS

    0.1% of full span

    Increase

    Integral Low

    Accuracy

    VALVES SPECIFICATIONVALVES SPECIFICATIONVALVES SPECIFICATIONVALVES SPECIFICATIONVALVES SPECIFICATIONVALVES SPECIFICATIONVALVES SPECIFICATIONVALVES SPECIFICATIONVALVES SPECIFICATIONVALVES SPECIFICATIONVALVES SPECIFICATIONVALVES SPECIFICATION

  • CUSTOMER : PVGAS D

    LOCATION : VIETNAM

    AREA : BLOCK 102 & 106 - PHASE 1 PROJECT No. AL-3098

    PROJECT : TB-HR LPGD PIPELINE SYSTEM SHEET

    1 Tag No.

    2 Service

    3 P&ID No.

    4 Line/Vessel No.

    5 Hazardous Area Classification

    6 Quantity

    7

    8 Fluid

    9 Phase

    10 Operating pressure Barg

    11 Operating temperature C

    12 Design pressure Barg

    13 Design Temperature C

    14 Operating differential Pressure mBar

    15 Liquid (mixture) density Kg/m3

    16 Vapour density Kg/m3

    17 Body or Chamber Material

    18 Magnetic Follower/Float Material

    19 Flange Material

    20 Flange Rating

    21 Process Connection Type

    22 Conn Size & Location : Upper

    23 Conn Size & Location : Lower

    24 Vent / Drain Conn. Type & Size

    25 Visible Length

    26 Center To Center Distance

    27 Indicator Type

    28 Indicator Scale

    29 Indicator Scale Material

    30 Manufacturer

    31 Model No.

    32 Service

    33

    34

    35

    36 Supply Voltage

    37

    38 Output Action

    39

    40 Enclosure: Material

    41 Contacts : No.

    42 Conduit Connection

    43 Ex Certification

    44 Mounting

    45 Drain and Vent Valves:

    46 NACE Compliant

    47

    NOTES : 1. Insulation support/clip shall be provided by Vendor for insulation installed by Purchaser.

    2. Refer to P&ID

    3. Transmitter shall be supplied with 316 SS, Ex i, ATEX certified plugs for all spare cable entries

    4. The rolling magnet type of indication with red and yellow follower.

    5 Transmitter enclosure/ casing/ junction box shall be epoxy-coated low copper aluminium.

    ITEM/TAG No. LZT-0114

    DATA SHEET No. KTA.TB-PAC03-J13-005.02

    4 OF 10

    INSTRUMENT DATA SHEETMAGNETIC LEVEL GAUGE WITH LEVEL TRANSMITTER

    ZONE 2, GROUP IIA, T3

    1 (One)

    PR

    OC

    ES

    S D

    ET

    AIL

    S

    Hydrocarbon

    Liquid

    13.7

    34.6 - 36.4

    40

    65

    N/A

    GE

    NE

    RA

    L

    LG-0114/LZT-0114

    Glycol Contactor C-101

    KTA.TB-PAC03-M07-001

    C-101

    716.1 - 994.9

    TR

    AN

    SM

    ITT

    ER

    VTA

    VTA

    Magnetic Level Gauge and Level Transmitter

    Indicate/Transmit

    0-100%

    4-20 mA (2-wire), HART comm. Protocol.

    24 V DC

    0.1% of full span

    Increase

    Integral Low

    M20x1.5

    EEx:ia IIB T4

    Class

    Form

    Aluminium (Note 5)

    9.41

    316 SS

    316 SS

    OT

    HE

    R

    Direct Mounted (Bottom)

    3/4" 600# WNRF FLAGNE

    N/A

    FL

    OA

    T M

    AT

    ER

    IAL

    316 SS

    ASME 600# RF WN

    Flanged

    DN50, Side

    DN50 Side

    Flanged 600# RF, DN 20

    IND

    ICA

    TO

    R 800mm

    800mm

    Magnetic flap

    Graduated in%

    316 SS

    IP65

    Function

    Range

    Output

    Accuracy

    Mounting

    VALVES SPECIFICATIONVALVES SPECIFICATIONVALVES SPECIFICATIONVALVES SPECIFICATIONVALVES SPECIFICATIONVALVES SPECIFICATIONVALVES SPECIFICATIONVALVES SPECIFICATIONVALVES SPECIFICATIONVALVES SPECIFICATIONVALVES SPECIFICATIONVALVES SPECIFICATION

  • CUSTOMER : PVGAS D

    LOCATION : VIETNAM

    AREA : BLOCK 102 & 106 - PHASE 1 PROJECT No. AL-3098

    PROJECT : TB-HR LPGD PIPELINE SYSTEM SHEET

    1 Tag No.

    2 Service

    3 P&ID No.

    4 Line/Vessel No.

    5 Hazardous Area Classification

    6 Quantity

    7

    8 Fluid

    9 Phase

    10 Operating pressure Barg

    11 Operating temperature C

    12 Design pressure Barg

    13 Design Temperature C

    14 Operating differential Pressure mBar

    15 Liquid (mixture) density Kg/m3

    16 Vapour density Kg/m3

    17 Body or Chamber Material

    18 Magnetic Follower/Float Material

    19 Flange Material

    20 Flange Rating

    21 Process Connection Type

    22 Conn Size & Location : Upper

    23 Conn Size & Location : Lower

    24 Vent / Drain Conn. Type & Size

    25 Visible Length

    26 Center To Center Distance

    27 Indicator Type

    28 Indicator Scale

    29 Indicator Scale Material

    30 Manufacturer

    31 Model No.

    32 Service

    33

    34

    35

    36 Supply Voltage

    37

    38 Output Action

    39

    40 Enclosure: Material

    41 Contacts : No.

    42 Conduit Connection

    45 Ex Certification

    46 Mounting

    47 Drain and Vent Valves:

    48 NACE Compliant

    49

    NOTES : 1. Insulation support/clip shall be provided by Vendor for insulation installed by Purchaser.

    2. Refer to P&ID

    3. Transmitter shall be supplied with 316 SS, Ex i, ATEX certified plugs for all spare cable entries

    4. The rolling magnet type of indication with red and yellow follower.

    5 Transmitter enclosure/ casing/ junction box shall be epoxy-coated low copper aluminium.

    ITEM/TAG No. LIT-0131

    DATA SHEET No. KTA.TB-PAC03-J13-005.02

    5 OF 10

    INSTRUMENT DATA SHEETMAGNETIC LEVEL GAUGE WITH LEVEL TRANSMITTER

    ZONE 2, GROUP IIA, T3

    1 (One)

    PR

    OC

    ES

    S D

    ET

    AIL

    S

    Hydrocarbon

    Liquid

    3.9

    70

    10

    100

    N/A

    GE

    NE

    RA

    L

    LG-0131/LIT-0131

    Flash Vessel

    KTA.TB-PAC03-M07-003

    V-101

    700

    TR

    AN

    SM

    ITT

    ER

    VTA

    VTA

    Magnetic Level Gauge and Level Transmitter

    Indicate/Transmit

    0-100%

    4-20 mA (2-wire), HART comm. Protocol.

    24 V DC

    0.1% of full span

    Increase

    Integral Low

    M20x1.5

    EEx:ia IIB T4

    Function

    Range

    Output

    4.75

    OT

    HE

    R

    Direct Mounted (Bottom / Top)

    3/4" 600# WNRF FLAGNE

    N/A

    DN50, Side

    DN50 Side

    Flanged 150# RF, DN 20

    FL

    OA

    T M

    AT

    ER

    IAL

    IND

    ICA

    TO

    R 850mm

    850mm

    Magnetic flap

    316 SS

    316 SS

    316 SS

    ASME 150# RF WN

    Flanged

    Graduated in%

    316 SS

    IP65

    Accuracy

    Mounting

    Class

    Form

    Aluminium (Note 5)

    VALVES SPECIFICATIONVALVES SPECIFICATIONVALVES SPECIFICATIONVALVES SPECIFICATIONVALVES SPECIFICATIONVALVES SPECIFICATIONVALVES SPECIFICATIONVALVES SPECIFICATIONVALVES SPECIFICATIONVALVES SPECIFICATIONVALVES SPECIFICATIONVALVES SPECIFICATION

  • CUSTOMER : PVGAS D

    LOCATION : VIETNAM

    AREA : BLOCK 102 & 106 - PHASE 1 PROJECT No. AL-3098

    PROJECT : TB-HR LPGD PIPELINE SYSTEM SHEET

    1 Tag No.

    2 Service

    3 P&ID No.

    4 Line/Vessel No.

    5 Hazardous Area Classification

    6 Quantity

    8 Fluid

    9 Phase

    10 Operating pressure Barg

    11 Operating temperature C

    12 Design pressure Barg

    13 Design Temperature C

    14 Operating differential Pressure mBar

    15 Liquid (mixture) density Kg/m3

    16 Vapour density Kg/m3

    19 Body or Chamber Material

    20 Magnetic Follower/Float Material

    21 Flange Material

    22 Flange Rating

    23 Process Connection Type

    24 Conn Size & Location : Upper

    25 Conn Size & Location : Lower

    26 Vent / Drain Conn. Type & Size

    27 Visible Length

    28 Center To Center Distance

    29 Indicator Type

    30 Indicator Scale

    31 Indicator Scale Material

    32 Manufacturer

    33 Model No.

    34 Service

    35

    36

    37

    38 Supply Voltage

    39

    40 Output Action

    41

    42 Enclosure: Material

    43 Contacts : No.

    44 Conduit Connection

    45 Ex Certification

    46 Mounting

    47 Drain and Vent Valves:

    48 NACE Compliant

    49

    NOTES : 1. Insulation support/clip shall be provided by Vendor for insulation installed by Purchaser.

    2. Refer to P&ID

    3. Transmitter shall be supplied with 316 SS, Ex i, ATEX certified plugs for all spare cable entries

    4. The rolling magnet type of indication with red and yellow follower.

    5 Transmitter enclosure/ casing/ junction box shall be epoxy-coated low copper aluminium.

    ITEM/TAG No. LIT-0132

    DATA SHEET No. KTA.TB-PAC03-J13-005.02

    6 OF 10

    INSTRUMENT DATA SHEETMAGNETIC LEVEL GAUGE WITH LEVEL TRANSMITTER

    ZONE 2, GROUP IIA, T3

    1 (One)

    PR

    OC

    ES

    S D

    ET

    AIL

    S

    TEG

    Liquid

    3.9

    70

    10

    100

    N/A

    GE

    NE

    RA

    L

    LG-0132/LIT-0132

    Flash Vessel

    KTA.TB-PAC03-M07-003

    V-101

    1079

    M20x1.5

    EEx:ia IIB T4

    4.75

    TR

    AN

    SM

    ITT

    ER

    VTA

    VTA

    Magnetic Level Gauge and Level Transmitter

    Indicate/Transmit

    0-100%

    4-20 mA (2-wire), HART comm. Protocol.

    24 V DC

    0.1% of full span

    Increase

    Integral Low

    FL

    OA

    T M

    AT

    ER

    IAL

    316 SS

    OT

    HE

    R

    Direct Mounted (Bottom)

    3/4" 600# WNRF FLAGNE

    N/A

    316 SS

    316 SS

    ASME 150# RF WN

    Flanged

    DN50, Side

    DN50 Side

    Flanged 150# RF, DN 20

    IND

    ICA

    TO

    R 1500mm

    1500mm

    Magnetic flap

    Graduated in%

    316 SS

    Class

    Form

    Aluminium (Note 5) IP65

    Function

    Range

    Output

    Accuracy

    Mounting

    VALVES SPECIFICATIONVALVES SPECIFICATIONVALVES SPECIFICATIONVALVES SPECIFICATIONVALVES SPECIFICATIONVALVES SPECIFICATIONVALVES SPECIFICATIONVALVES SPECIFICATIONVALVES SPECIFICATIONVALVES SPECIFICATIONVALVES SPECIFICATIONVALVES SPECIFICATION

  • CUSTOMER : PVGAS D

    LOCATION : VIETNAM

    AREA : BLOCK 102 & 106 - PHASE 1 PROJECT No. AL-3098

    PROJECT : TB-HR LPGD PIPELINE SYSTEM SHEET

    1 Tag No.

    2 Service

    3 P&ID No.

    4 Line/Vessel No.

    5 Hazardous Area Classification

    6 Quantity

    7

    8 Fluid

    9 Phase

    10 Operating pressure Barg

    11 Operating temperature C

    12 Design pressure Barg

    13 Design Temperature C

    14 Operating differential Pressure mBar

    15 Liquid (mixture) density Kg/m3

    16 Body or Chamber Material

    17 Magnetic Follower/Float Material

    18 Flange Material

    19 Flange Rating

    20 Process Connection Type

    21 Conn Size & Location : Upper

    22 Conn Size & Location : Lower

    23 Vent / Drain Conn. Type & Size

    24 Visible Length

    25 Center To Center Distance

    26 Indicator Type

    27 Indicator Scale

    28 Indicator Scale Material

    29 Manufacturer

    30 Model No.

    31 Service

    32

    33

    34

    35 Supply Voltage

    36

    37 Output Action

    38

    39 Enclosure: Material

    40 Contacts : No.

    41 Conduit Connection

    42 Ex Certification

    43 Mounting

    44 Drain and Vent Valves:

    45 NACE Compliant

    46

    NOTES : 1. Insulation support/clip shall be provided by Vendor for insulation installed by Purchaser.

    2. Refer to P&ID

    3. Transmitter shall be supplied with 316 SS, Ex i, ATEX certified plugs for all spare cable entries

    4. The rolling magnet type of indication with red and yellow follower.

    5 Transmitter enclosure/ casing/ junction box shall be epoxy-coated low copper aluminium.

    IP65

    Accuracy

    Mounting

    Class

    Form

    Aluminium (Note 5)

    IND

    ICA

    TO

    RF

    LO

    AT

    MA

    TE

    RIA

    L

    316 SS

    316 SS

    316 SS

    ASME 150# RF WN

    Flanged

    DN50, Side

    DN50 Side

    Flanged 150# RF, DN 20

    900mm

    900mm

    Magnetic flap

    Graduated in%

    316 SS

    ITEM/TAG No. LIT-0141

    DATA SHEET No. KTA.TB-PAC03-J13-005.02

    7 OF 10

    INSTRUMENT DATA SHEETMAGNETIC LEVEL GAUGE WITH LEVEL TRANSMITTER

    ZONE 2, GROUP IIA, T3

    1 (One)

    PR

    OC

    ES

    S D

    ET

    AIL

    S

    TEG

    Liquid

    0.25

    82.4 - 94

    7.5

    100

    N/A

    GE

    NE

    RA

    L

    LG-0141/LIT-0141

    Glycol Surge Drum

    KTA.TB-PAC03-M07-004

    V-103

    1066.1

    TR

    AN

    SM

    ITT

    ER

    VTA

    VTA

    Magnetic Level Gauge and Level Transmitter

    Indicate/Transmit

    0-100%

    4-20 mA (2-wire), HART comm. Protocol.

    24 V DC

    0.1% of full span

    Increase

    Integral Low

    Function

    Range

    Output

    M20x1.5

    EEx:ia IIB T4

    OT

    HE

    R

    Direct Mounted (Bottom)

    3/4" 600# WNRF FLAGNE

    N/A

    VALVES SPECIFICATIONVALVES SPECIFICATIONVALVES SPECIFICATIONVALVES SPECIFICATIONVALVES SPECIFICATIONVALVES SPECIFICATIONVALVES SPECIFICATIONVALVES SPECIFICATIONVALVES SPECIFICATIONVALVES SPECIFICATIONVALVES SPECIFICATIONVALVES SPECIFICATION

  • CUSTOMER : PVGAS D

    LOCATION : VIETNAM

    AREA : BLOCK 102 & 106 - PHASE 1 PROJECT No. AL-3098

    PROJECT : TB-HR LPGD PIPELINE SYSTEM SHEET

    1 Tag No.

    2 Service

    3 P&ID No.

    4 Line/Vessel No.

    5 Hazardous Area Classification

    6 Quantity

    7

    8 Fluid

    9 Phase

    10 Operating pressure Barg

    11 Operating temperature C

    12 Design pressure Barg

    13 Design Temperature C

    14 Operating differential Pressure mBar

    15 Liquid (mixture) density Kg/m3

    16 Body or Chamber Material

    17 Magnetic Follower/Float Material

    18 Flange Material

    19 Flange Rating

    20 Process Connection Type

    21 Conn Size & Location : Upper

    22 Conn Size & Location : Lower

    23 Vent / Drain Conn. Type & Size

    24 Visible Length

    25 Center To Center Distance

    26 Indicator Type

    27 Indicator Scale

    28 Indicator Scale Material

    29 Manufacturer

    30 Model No.

    31 Service

    32

    33

    34

    35 Supply Voltage

    36

    37 Output Action

    38

    39 Enclosure: Material

    40 Contacts : No.

    41 Conduit Connection

    42 Ex Certification

    47 Mounting

    48 Drain and Vent Valves:

    49 NACE Compliant

    50

    NOTES : 1. Insulation support/clip shall be provided by Vendor for insulation installed by Purchaser.

    2. Refer to P&ID

    3. Transmitter shall be supplied with 316 SS, Ex i, ATEX certified plugs for all spare cable entries

    4. The rolling magnet type of indication with red and yellow follower.

    5 Transmitter enclosure/ casing/ junction box shall be epoxy-coated low copper aluminium.

    Class

    Form

    Aluminium (Note 5) IP65

    FL

    OA

    T M

    AT

    ER

    IAL

    Function

    Range

    Output

    Accuracy

    Mounting

    Flanged 150# RF, DN 20

    600mm

    600mm

    Magnetic flap

    Graduated in%

    316 SSIN

    DIC

    AT

    OR

    ASME 150# RF WN

    Flanged

    DN50, Side

    DN50 Side

    ITEM/TAG No. LZT-0151

    DATA SHEET No. KTA.TB-PAC03-J13-005.02

    8 OF 10

    INSTRUMENT DATA SHEETMAGNETIC LEVEL GAUGE WITH LEVEL TRANSMITTER

    ZONE 2, GROUP IIA, T3

    1 (One)

    PR

    OC

    ES

    S D

    ET

    AIL

    S

    TEG

    Liquid

    0.30

    204

    7.5

    235

    N/A

    GE

    NE

    RA

    L

    LG-0151/LZT-0151

    Glycol Reboiler

    KTA.TB-PAC03-M07-005

    V-102

    969.9

    316 SS

    316 SS

    316 SS

    TR

    AN

    SM

    ITT

    ER

    VTA

    VTA

    Magnetic Level Gauge and Level Transmitter

    Indicate/Transmit

    0-100%

    4-20 mA (2-wire), HART comm. Protocol.

    24 V DC

    0.1% of full span

    Increase

    Integral Low

    M20x1.5

    EEx:ia IIB T4

    OT

    HE

    R

    Direct Mounted (Bottom )

    3/4" 600# WNRF FLAGNE

    N/A

    VALVES SPECIFICATIONVALVES SPECIFICATIONVALVES SPECIFICATIONVALVES SPECIFICATIONVALVES SPECIFICATIONVALVES SPECIFICATIONVALVES SPECIFICATIONVALVES SPECIFICATIONVALVES SPECIFICATIONVALVES SPECIFICATIONVALVES SPECIFICATIONVALVES SPECIFICATION

  • CUSTOMER : PVGAS D

    LOCATION : VIETNAM

    AREA : BLOCK 102 & 106 - PHASE 1 PROJECT No. AL-3098

    PROJECT : TB-HR LPGD PIPELINE SYSTEM SHEET

    1 Tag No.

    2 Service

    3 P&ID No.

    4 Line/Vessel No.

    5 Hazardous Area Classification

    6 Quantity

    7

    8 Fluid

    9 Phase

    10 Operating pressure Barg

    11 Operating temperature C

    12 Design pressure Barg

    13 Design Temperature C

    14 Operating differential Pressure mBar

    15 Liquid (mixture) density Kg/m3

    16 Body or Chamber Material

    17 Magnetic Follower/Float Material

    18 Flange Material

    19 Flange Rating

    20 Process Connection Type

    21 Conn Size & Location : Upper

    22 Conn Size & Location : Lower

    23 Vent / Drain Conn. Type & Size

    24 Visible Length

    25 Center To Center Distance

    26 Indicator Type

    27 Indicator Scale

    28 Indicator Scale Material

    29 Manufacturer

    30 Model No.

    31 Service

    32

    33

    34

    35 Supply Voltage

    36

    37 Output Action

    38

    39 Enclosure: Material

    40 Contacts : No.

    41 Conduit Connection

    42 Ex Certification

    43 Mounting

    44 Drain and Vent Valves:

    45 NACE Compliant

    46

    NOTES : 1. Insulation support/clip shall be provided by Vendor for insulation installed by Purchaser.

    2. Refer to P&ID

    3. Transmitter shall be supplied with 316 SS, Ex i, ATEX certified plugs for all spare cable entries

    4. The rolling magnet type of indication with red and yellow follower.

    5 Transmitter enclosure/ casing/ junction box shall be epoxy-coated low copper aluminium.

    IP65

    Function

    Range

    Output

    Accuracy

    Mounting

    IND

    ICA

    TO

    R 800mm

    800mm

    Magnetic flap

    Graduated in%

    316 SS

    FL

    OA

    T M

    AT

    ER

    IAL

    ASME 150# RF WN

    Flanged

    DN50, Side

    DN50 Side

    Flanged 150# RF, DN 20

    316 SS

    316 SS

    316 SS

    ITEM/TAG No. LIT-0171

    DATA SHEET No. KTA.TB-PAC03-J13-005.02

    9 OF 10

    INSTRUMENT DATA SHEETMAGNETIC LEVEL GAUGE WITH LEVEL TRANSMITTER

    ZONE 2, GROUP IIA, T3

    1 (One)

    PR

    OC

    ES

    S D

    ET

    AIL

    S

    Water

    Liquid

    0.20

    37

    7.5

    100

    N/A

    GE

    NE

    RA

    L

    LG-0171/LIT-0171

    Reflux Drum

    KTA.TB-PAC03-M07-007

    V-104

    993.4

    TR

    AN

    SM

    ITT

    ER

    VTA

    VTA

    Magnetic Level Gauge and Level Transmitter

    Indicate/Transmit

    0-100%

    4-20 mA (2-wire), HART comm. Protocol.

    24 V DC

    0.1% of full span

    Increase

    Integral Low

    M20x1.5

    EEx:ia IIB T4

    Class

    Form

    Aluminium (Note 5)

    OT

    HE

    R

    Direct Mounted (Bottom)

    3/4" 600# WNRF FLAGNE

    N/A

    VALVES SPECIFICATIONVALVES SPECIFICATIONVALVES SPECIFICATIONVALVES SPECIFICATIONVALVES SPECIFICATIONVALVES SPECIFICATIONVALVES SPECIFICATIONVALVES SPECIFICATIONVALVES SPECIFICATIONVALVES SPECIFICATIONVALVES SPECIFICATIONVALVES SPECIFICATION

  • CUSTOMER : PVGAS D ITEM/TAG No.

    LOCATION : VIETNAM DATA SHEET No. KTA.TB-PAC03-J13-005.02

    AREA : BLOCK 102 & 106 - PHASE 1 PROJECT No. AL-3098

    PROJECT : TB-HR LPGD PIPELINE SYSTEM SHEET 10 OF 10

    GENERAL NOTES

    1. Documentation Required:

    Hazardous Area Certificate - ATEX certification

    Ingress Protection Certificate

    Hydrotest Certificate

    Calibration Certificate (5 points) issued by manufacturer

    Material Certificate, ISO-EN 10204, Type 3.1 (B) for pressure retaining parts.

    Installation & Commissioning spare Parts List and 2 years Operational Spares List

    Compliance/ Conformance Certificate

    General Arrangement drawing with complete Model Numbers, Dimension and Hookup details

    2. All instruments shall be provided with a SS 316 name plate with tag no. pernamently inscribed

    3 Level transmitters and accessories shall be able to sustain process design pressure, temperature and service fluid.

    4 Level transmitters and accessories should meet the following specifications:

    Specification for instrumentation KTA.TB-PAC03-M65-007

    5 Elastomer used in the instrument / accessories are compatible with the service fluid specified at design conditions.

    6 All tube fittings shall be SS316, of Swagelok make, imperial size, double compression type.

    7 Field bus based transmitter/ devices must satisfy the requirements of the field bus registration laboratory with applicable checkmark of foundation field bus.

    8 The field bus instruments in hazardous area shall be certified as per entity concept or shall be FISCO approved.

    9 Internal software shall be configured by the vendor including the following information such as serial number, Device Tag (Tag Number) and Process description.

    10 Bolts/nut ASTM A193 Gr.B7/A194-2H with xylan flourocarbon coated

    INSTRUMENT DATA SHEET

    MAGNETIC LEVEL GAUGE WITH LEVEL TRANSMITTER- NOTES

    VALVES SPECIFICATIONATION SHEETVALVES SPECIFICATIONATION SHEETVALVES SPECIFICATIONATION SHEETVALVES SPECIFICATIONATION SHEET