retrofitting multifamily homes in new mexico - 2020 · in order to aid with the multifamily...
TRANSCRIPT
RetrofittingMultifamilyHomesinNewMexico-2020
StandardWorkSpecificationsFieldGuidefor
MultifamilyHomescreatedby
NewMexicoMortgageFinanceAuthorityNMEnergySmart...NewMexicoMortgageFinanceAuthority
January08,2020
Inordertoaidwiththemultifamilyassessmentandfieldguideuse,commpletetheworksheetusingthefollowingcodes:
1.N=NotApplicable2.E=Existingandalreadycompliant
3.W=Putontheworkorder4.A=completedattheassessmentlevel
I.HealthandSafety(Section2SWS)
WorkerSafety:
____Hazzardassessment____Leadtestingorageofbuilding____Electricalassessment
____Airbornecontamination____Watersourcesclosetowires____Knobandtube____Accessandegresspoints____Moisture____Mold____RodentsorInsects____Evaluationofwires____Unsafebuildingassemblies____Exposedearth____Dewpointsgreaterthan55F____Exteriorwatermanagement____Gradingdrainage____PPE____Adequateventilation
Occupanthealthandsafety:
____Allcombustionairtocode
____Hazardousmaterialsremovedfrommechanicalroom____Mechanicalroomdoorsclosed____LowVOCproductstobeused
____Sealantsintendedtobecontinuousandfireresistant
____Ventingsystemsproperpitch,material,commonventing,clearance,length
____Lockingrefrigerantcapsonaccesspoints____Roofleaksverifiedandrepaired____EPAguidelinesfollowedforcurrenteditionof“HealthyIndoorEnvironmentProtocolsforHomeEnergyRetrofits”____Radontestforconcretemasonrymultistoryunits____Fibrousinsulationwillbeencapsulated
OccupantandBuildingStaffEducation:
____Basicoperationofequipment
____Properoperationofsystemcontrols____Electricaldisconnectsandfuelshutoffsdemonstrated____Locationofcombustionairinletsidentified____Importanceofnotblockinginlets
____Importanceofcleaningdustanddebrisfromreturngrills____Properplacementofinteriorfurnishingsinrespecttoregisters
____Negativeconsequencesofclosingregisters____Leavinginteriordoorsopenasmuchaspossible____Howtochangefilter____Keepingoutdoorunitsclearofdebris____Timingofroutineprofessionalmaintenance
____Whenoccupantsaretocontactmaintenance____UseofCOalarm____Warrantymanuals____Laborwarranties____Contactinformation
II.AirSealing(Section3SWS)
PenetrationsandChases,FirewallinUnconditionedAttic,WallPenetrations,AtticAccess,ConcreteFloorSlab,GeneralAirSealing:
____Gaps,cracks,andholesinfireseparationsidentified____Backingorinfillneedevaluatedwheregapsarelargerthan¼”____Airsealinglocationsidentifiedbetweenfirewallandattic____Backingorinfillselectedthatallowforexpansionandcontraction____Backingorinfillselectedmeetsfireratingofexistingmaterials____Selectedsealantscompatiblewithintendedsurfaces____SelectedsealantslowVOC____Fire-resistantratingsidentifiedonavailabledrawings____Fire-resistantratinginferredfrommaterials____Fluesdesigntonotpresentfire,health,orsafetyrisk____Attichatcheswillbeinsulatedwithnon-compressibleinsulation____Rooforoutsideaccessinspectedforairandwaterleakage,security,warping,andproperoperation____IdentificationofairandthermalboundaryDoors,windowsandskylightsmaintenance:
____Doorsinspectedtoproperlyfitjambandeaseofoperation____Weatherstrippingchosenwillbeaneffectiveairbarrier____Doorsinspectedforcurb,stability,warping,properhardwareoperation,security,air,andwaterleakage____Skylightandwindowglazinginspectedforcurb,stability,warping,properhardwareoperation,security,airandwaterleakage____Insulationstrategydeterminedforskylights
Doorandwindowreplacement:
____Glazingtypechosenbylocationinbuilding,buildingheight,code,andclimate____Glazingsolarheatgaincoefficientselectedbybuildingorientationandclimate____Windowand/ordoorselectionNFRCratingbyclimate____WindowanddoorlowestpossibleUvaluechosen____SHPOconsidered____SealantscompatiblewithselectedsurfacesandlowVOC____Doorframeinsulationselectedwiththermalbreaksappropriatetoclimate____Doorselectedwithlowestpossibleairleakagerating
DuctsPreparation,Fastening,andSupport,ForcedAir:____Ductfasteningcurrentlycompliantwith3.1601.6,8____Ductsupportcurrentlycompliantwith3.1601.7,9____Airtightfilterslotcoverneeded____Ductfasteningmodificationneededtocomplywith3.1601.6,8____Ductsupportmodificationneededtocomplywith3.1601.7,9____DuctsealantconsideredwillbeUL181compliantandmeetfirebarrierspecs
III.Insulation(Section4SWS)
LooseFilloverExistingandFlatRoof:
____Airsealingneeded____Electricaljunctionsneedattention,flagging____Blockingneededforventing____IntendedmaterialsmeetASTME84flamespreadrating
____Existinginsulationinfullcontactwithairbarrier____Damsneeded____ICcanlightboxespresent
Installation/CorrectionofUnconditionedAtticVentilation:
____Airbarriereffectiveandpresent____Airsealingpartofscopeorwork____Bafflingforatticsoffitventsneeded
____1/8”non-corrodingwiremeshscreensneeded____Ventingopeningareaandconfigurationcalculatedtocomplywithcodes
____Ignitionandthermalboundariesprovidediffoamplasticused____Placementofnewventsdeterminingproperairflow____Placementofnewventsprevententryofwinddrivenrainorsnow
DensePackingBlownInsulation:
____Leadsafetyproceduresneeded(builtpriorto1980)4.1003.4____Fireseparationsconsidered____Repairsneededtostabilizeworkarea____Moisturerelatedissuestoresolve____Airsealinglocationonexterioridentified____Airbarriereffectiveandpresent____Sealantsselectedcompatiblewithintendedsurfaces,lowVOCandfireresistant____Airsealingpartofscopeorwork
____Possibletoremoveexteriorcladding____Insulationaccesspointsidentified____MaterialsselectedmeetrequirementsofSWS4.1103.14f
ExteriorWallSurfaceInsulation:
____Priorrepairsnecessary____IRCthermalboundary(firestopping)____Leadsafepracticesneeded____Moisturerelatedissuestoresolve____Watercontrolmeasures____Airsealinglocationsidentifiedonoutsidewalls____Sealantsselectedcompatiblewithintendedsurfaces,lowVOC,durable,pestresistantandfireresistant____Airsealingpartofscopeorwork
____Mold,waterleaks,pestsremoved
Above-GradeExposedFloor,JoistedAssemblies:
____Gaps,cracks,andholesinfireseparationlocated____Repairsnecessarytostabilizework____Isolationneededforleadorasbestos____Plantoinstallinsulationincontactwithsubfloorwithnotgaps,voidsorcompressions____Lightingtobeprovided____Sealantsselectedcompatiblewithintendedsurfaces,lowVOC,durable,pestresistantandfireresistant____Airsealingpartofscopeorwork
____Vaporretarderplans
IV.HeatingandCooling(Section5SWS)
EquipmentSelection:
____Designnotmorethan115%ofload____Lowestcapacityrequiredheatingequipmentused____Lowestcapacityrequiredcoolingequipmentused____Compliantwith5.3001.4
Ductworkandterminationdesign,maintenance:
____DuctsdesignedusingManualD____Returngrilleequaltoorlargerthanbox____Designusingfrictioncharts____Firedampersneeded____Existingbuildingcavitiesnotused____Compliantwith5.3001.5____Compliantwithcode____Fireratingcodecompliant____AirflowmeetspertonspecsandASHRAEstandards____Totalleakagenotmorethan20%ofdesignedsystemairflowwhentestedat25pascals____Vaporretarder____Supportedproperly____Penetrationsthroughfirewallssealedwithfire-ratedmaterial____Penetrationsthroughinteriorwallssealedwithdurablesealant
ElectricalService:
____Correctpolarity____Wiresizeappropriate
____Voltagetomanufacturerspecs____Properdisconnectservicewithfusesinstalled____Voltagedropwithinacceptablerange____Adequategrounding____Amperagewithincoderequirements____Blowercompartmentsafetyswitchoperationverified____EmergencyheatcircuitfunctionverifiedAirFlow:
____Airhandlerhasproperrotation____Pressuredropacrosscoilstomanufacturerspecs____Supplywetanddrybulbtemprecorded____Thermostatwetanddrybulbtemprecorded____Returnwetanddrybulbtemprecorded____Fanflowtodesignspecs____Pressuredropacrossfilterto
Manufacturerspecs
____TotalairflowtoASHRAEStandard111____Outdoortemperaturesensorinstalledwithmanufacturerspecsforheatpumps
____ThermalandeconomicbalancepointcalculatedwithoptimumbalancepointselectinaccordancewithANSI/ACCAManualS
FuelDeliverySystem:
____ExistingpipingapprovedwithNFPA____Shutoffvalve,unionjoint,anddriplegverified____Gaslinesleakfreewithcode-approvedstandingpressuretest
VentingSystem:
____VentingterminationinaccordancewithNFPA54,31,211____Category1ventinginaccordancewithNFPA54/ANSIZ223.1____Ventjointsairtightandwatertight
CombustionAnalysis:
____Burnerorificesizewithmanufacturerspecs____Stacktemperaturemeasuredandverifiedwithmanufacturerspecs____Oxygenwithmanufacturerspecs____Gaspressureverifiedwithmanufacturerspecs____CarbonDioxidewithmanufacturerspecs____Excessairwithmanufacturerspecs____COinundilutedfluegaslessthanlevelspecifiedinANZIZ21
CondensateLine:
____Connectionswatertight____Overflowprotection____Drainedbygravityorpumps____Ventsandtrapsinstalled____Drainpanwherewaterdamagecanoccur
RefrigerantLineandChargeInspection:
____Existinginsulationonthelines____Securedtobuildinginmannerthatprotectslinefromdamage____Chargeverified____Linescheckedforleaks____IfexposedtosunlightarethelinesprotectedfromUVdegradation____SuperheatandSubcoolingtestsdoneunderoutdoorambienttemperatures
____Terminationinaccordancewithlocalcode
EvaporativeCoolerMaintenanceandRepair:
____Allsystemelementsassessed:spider,pan,pump,float,damper,roofjack,waterline,electrical,pads,motor,fan.____Existingcalciumdepositstoberemoved
ThroughtheWallAC:
____UnitandelectricalreceptaclemeetsNFPA70,article440____Availablevoltagematched
____ReplacementEnergyStar____Wallopeningsizedetermined
V.Ventilation(Section6SWS)
ExhaustServingMultipleRooms:
____Localcoderequirementsfollowed____Outsideterminationlocationinspectedforscreenandlouveredcover____Exhaustoutletlocationlocalcodecompliant____AirflowmeasuredandASHRAE62.22013calculated____Fanandserviceswitchtobeaccessible____Newductstobesealedtocode____DuctstohaveinsulationofR8____Ductrunand90spossibleformanufacturerspecs____Exhaustoutletsealedtopreventwaterleakageorairleakageintobuildingcavaties____Kitchenrangehoodexhaustedtooutside____Securemountingpossible
VII.Baseloads(Section7SWS)
Refrigerators,lighting,lowflowdevices:
____ElectricalreceptaclemeetsNFPA70Article440____Exitsignsconsideredandmaximumof5watts____EmergencylightingmeetsULstandard542,1570andNFPA70,700.12____PlannedlightinglevelsincommonareascompliantwithASHRAE90.1or90.2____PlannedegresslightinginaccordancewithANSI/NFPA70and101____PlannedCFLstobeEnergyStar____TubularlightballastsPCPfree____Unusualpressureconditionsnoted
StorageTankWaterHeater,piping,expansiontank:
____Potentialhealthconcernsinremovalofoldsystemidentified____Visibleabandonedpipingtoberemoved____Dissimilarmetalsconnectedtopreventgalvanicaction(di-electricunions)____PlumbinggroundedandbondedasrequiredbyNEC(NFPA70)____Pressurecheckedusingtirepressuregauge____Incomingstreetpressurechecked
2 HealthandSafety2.01 SafeWorkPractices2.0100 SafeWorkPractices2.0100.1 GlobalWorkerSafety2.0100.1b Handprotection2.0100.2 WorkAreaInspectionandStabilization2.0100.2c Identifyenvironmentalconditionsthatmaycreateorworsenunsafeorunstablebuildingassemblyconditions2.0100.2d Addressandcorrecthazardousoradverseconditions2.0101 AirSealing2.0101.1 AirSealingWorkerSafety2.0101.1a Workersafety2.0101.1b Moistureprecautionsforcrawlspacesandbasements2.0101.1c Moistureprecautions:livingspace2.0101.1d Moistureprecautionsforexteriorwater2.0105 Baseload
2.0105.2 LicensedElectricalProfessional2.0105.2a Workersafety2.0106 MaterialSafety2.0106.2 PotentialAsbestos-ContainingMaterials2.0106.2a Determineiftestingisnecessary2.0106.2b IfACMmaybepresent,educatepropertymanagerforneedoftesting2.02 CombustionSafety2.0203 VentedGasAppliances2.0203.3 CombustionAir—Boilers2.0203.3a Combustionair2.0203.3b Education2.0204 Isolation2.0204.2 IsolatingCombustionApplianceRooms(e.g.,BoilerRoom,FurnaceRoom,andGeneratorRoom)2.0204.2a Pre-inspection2.0204.2b Identificationofpenetrations2.0204.2c Preparation2.0204.2d Sealantandmaterialsselection2.0204.2e Verification2.0205 GasandOil-FiredEquipment2.0205.1 GasandOil-FiredEquipment2.0205.1a Combustionair2.0205.1b Installation2.0205.1c Orphanedequipment2.05 Radon2.0502 TestingandEvaluation2.0502.1 RadonTestingandEvaluation2.0502.1a Radontestingandmitigation2.07 OccupantEducationandAccess2.0702 InstalledEquipment2.0702.2 OccupantEducation2.0702.2a Systemoperation2.0702.2b Systemcontrols(e.g.,thermostat,humidistat)2.0702.2c Systemdisconnects2.0702.2d Combustionairinlets2.0702.2e Blockedairflow2.0702.2f Routinemaintenance2.0702.2g Occupantservicerequests2.0702.2h Carbonmonoxide(CO)2.0702.2i Warrantyandservice2.0703 Insulation2.0703.1 Sealing/IsolatingExposedFibrousInsulationinAreaswithRoutineHumanActivity2.0703.1a FibrousInsulationIsolation3 AirSealing3.10 Attics3.1001 PenetrationsandChases3.1001.5 PenetrationsandChases3.1001.5a Pre-inspection3.1001.5b Backingandinfill3.1001.5c Sealantselection3.1001.5d Hightemperatureapplication3.1001.6 FirewallinUnconditionedAttic3.1001.6a Pre-inspection3.1001.6b Backingandinfill3.1001.6c Sealantselection3.1001.6d Jointseal3.1001.8 PreparingforandInstallingInsulationAroundHigh-TemperatureDevices,Systems,andComponents3.1001.8a Pre-Inspection3.1001.8b Verifyatticprep3.1001.8c Isolatehigh-temperatureelements3.1001.8d Sealantselection3.1001.8e Safety3.1001.8f Buildingoperationsstaffeducation3.1001.9 SealingAccessDoorsandSimilarIntentionalPenetrations3.1001.9a Workersafety3.1001.9b Occupantsafety3.1001.9c Pre-inspection3.1001.9d Sealantselection
3.1001.9e Sealing3.1001.9f Installation3.1001.9g Attachment3.1001.9h Qualityassurance3.1001.9i Durability3.1001.9j Buildingoperationsstaff/occupanteducation3.1005 OtherCeilingMaterials3.1005.3 AirSealingComplexCeilingPlanes3.1005.3a Pre-inspection3.1005.3b Locateairsealingplane3.1005.3c Spanningmaterialselection3.1005.3d Support3.1005.3e Jointseal3.1005.3f Sealantselection3.11 Walls3.1102 MultifamilyWalls3.1102.1 WallPenetrationSealing3.1102.1a Pre-inspection3.1102.1b Backingandinfill3.1102.1c Sealantselection3.1102.1d High-temperatureapplication3.1102.1e Penetrationseal3.12 WindowsandDoors3.1201 Maintenance,Repair,andSealing3.1201.7 Repair,Maintenance,andWeatherStrippingofWindows3.1201.7a Workersafety3.1201.7b Occupantsafety3.1201.7c Pre-inspection3.1201.7d Operableglazingsystemoperationandfit3.1201.7e Fixedglazingsystemadjustmentandseal3.1201.7f Sealantselection3.1201.7g Framesealing3.1201.7h Weatherstripping3.1201.7i Qualityassurance3.1201.8 Repair,Maintenance,andWeatherStrippingofDoors3.1201.8a Workersafety3.1201.8b Occupantsafety3.1201.8c Pre-inspection3.1201.8d Dooroperationandfit3.1201.8e Sealantselection3.1201.8f Framesealing3.1201.8g Weatherstripping3.1201.8h Qualityassurance3.1203 Replacement3.1203.4 WindowReplacement3.1203.4a Designconsiderations3.1203.4b Pre-Inspection3.1203.4c Workersafety3.1203.4d Occupantsafety3.1203.4e Sealantselection3.1203.4f Windowlocation,installation,andsealing3.1203.4g Qualityassurance3.1203.5 ExteriorDoorReplacement3.1203.5a Designconsiderations3.1203.5b Workersafety3.1203.5c Occupantsafety3.1203.5d Sealantselection3.1203.5e Doorlocation,installationandsealing3.1203.5f Qualityassurance3.14 BasementsandCrawlSpaces3.1403 SlabFoundations3.1403.1 AirSealConcreteFloorSlabFoundation:Raised,OnGrade,andBelow-Grade3.1403.1a Pre-inspection3.1403.1b Identificationofpenetrations3.1403.1c Preparation3.1403.1d Sealantandmaterialsselection3.1403.1e Demolitionrepair3.1403.1f Verification3.16 Ducts3.1601 DuctPreparation
3.1601.6 PreparationandMechanicalFastening—LowRise3.1601.6a Preparation3.1601.6b Metaltometal3.1601.6c Flextometal3.1601.6d Ductboardtoductboard3.1601.6e Ductboardtoflexibleduct3.1601.6f Metalplenumtoairhandlercabinet3.1601.6g Ductboardplenumtoairhandlercabinet3.1601.6h Terminalboottowood3.1601.6i Terminalboottogypsum3.1601.6j Ductboardtoflex3.1601.6k Replacementofinsulation3.1601.7 Support—LowRise3.1601.7a Supportofducttypes(appliestoallducttypes)3.1602 DuctSealing3.1602.14 Heating,Ventilation,andAirConditioningSupply,andReturnDuctsandPlenums3.1602.14aSupplyplenums(includesconditionedcrawlspaces)3.1602.14bReturnplenums3.1602.14cExistingconditionwherecrawlspaceisusedassupplyand/orreturnplenum3.1602.15 VentilationExistingDuctSealing(AllBuildingTypes)3.1602.15aPre-inspection3.1602.15bHealthandsafety3.1602.15cIdentificationofleakagelocations3.1602.15dIdentifyandprioritizeleakagelocationstobesealed3.1602.15eTemporaryaccess3.1602.15f Preparation3.1602.15gMaterialselection3.1602.15hDuctsealing3.1602.15i Verification3.1602.15j Combustionappliancezonetesting3.1602.15kOccupant/propertymanagereducation3.1602.16 ForcedAir—AirSealingSystem—LowRise3.1602.16aNewcomponenttonewcomponentsealantselection3.1602.16bNewcomponenttoexistingcomponent3.1602.16cExistingcomponenttoexistingcomponent3.1602.17 ForcedAir—AirSealingSystemComponents—LowRise3.1602.17aDuctboottointeriorsurface3.1602.17bWoodenplenumsandbuildingcavities3.1602.17cAirhandlercabinet3.1602.17dFilterslot3.1602.18 FramedPlatform—LowRise3.1602.18aPreparation3.1602.18bInfillandbacking3.1602.18cSealantselection3.18 Roofs3.1802 Roof/WallConnections3.1802.1 Roof/ExteriorWallConnection,IncludingJointsatRoof/Parapet/WallConnections3.1802.1a Pre-inspection3.1802.1b Backingandinfill3.1802.1c Sealantselection3.1802.1d Jointseal3.1802.1e Cavityseal3.1802.2 ExteriorOverhangsCommunicatingtoorThroughPressureBoundary3.1802.2a Workersafety3.1802.2b Occupantsafety3.1802.2c Pre-inspection3.1802.2d Site3.1802.2e Backingandinfill3.1802.2f Sealantselection3.1802.2g Airbarrier3.1802.2h Qualityassurance3.1802.2i Ignitionbarrier/fireproofing3.19 Compartmentalization3.1901 MultifamilyCompartmentalizationTechniques3.1901.1 GeneralCompartmentalizationTechniques3.1901.1a Pre-inspection3.1901.1b Identificationofpenetrations3.1901.1c Preparation3.1901.1d Sealantandmaterialsselection3.1901.1e Verification3.1901.2 Performance-BasedAirSealingofDwellingUnitsandCorridors3.1901.2a Pre-inspection
3.1901.2b Workcoordinationamongtrades3.1901.2c Preparation3.1901.2d Identificationofpenetrations3.1901.2e Installation,sealant,andmaterialsselection3.1901.2f Verification3.1901.2g Propertymanager/occupanteducation3.1901.3 ChaseWays(e.g.,ServiceSpacesContainingPipes,Wires,Ducts,and/orStructuralComponents;IncludesDumbwaitersandTrashChutes)3.1901.3a Pre-inspection3.1901.3b Identificationofpenetrations3.1901.3c Preparation3.1901.3d Installation,sealant,andmaterialsselection3.1901.3e Demolitionrepair3.1901.3f Verification4 Insulation4.10 Attics4.1003 AtticCeilings4.1003.14 AccessibleUnventedFlatRoofwithorwithoutExistingInsulation4.1003.14aWorkersafety4.1003.14bOccupantsafety4.1003.14cPre-inspection4.1003.14dPreparation4.1003.14eInstallation4.1003.14f Ventilation4.1003.14gOccupanteducation4.1005 AtticFloors4.1005.8 LooseFillOverExistingInsulationonAccessibleAtticFloors4.1005.8a Preparation4.1005.8b Installation4.1005.8c Safety4.1005.8d Onsitedocumentation4.1088 SpecialConsiderations4.1088.8 Installation/CorrectionofUnconditionedAtticVentilation4.1088.8a Pre-inspection4.1088.8b Airbarrierandthermalboundary4.1088.8c Venttype4.1088.8d Ventlocation4.1088.8e Ventilationbaffling4.1088.8f Ventilationscreens4.11 Walls4.1103 EnclosedWalls4.1103.4 DensePackingBlownInsulation4.1103.4a Workersafety4.1103.4b Occupantsafety4.1103.4c Pre-inspection4.1103.4d Wallaccess4.1103.4e Sealantselection4.1103.4f Exteriordensepack4.1103.4g Onsitedocumentation4.13 Floors4.1301 AccessibleFloors4.1301.10 Above-GradeExposedFloor,JoistedAssemblies4.1301.10aPre-inspection4.1301.10bPreparation4.1301.10cSubfloorpreparation4.1301.10dInstallation4.1301.10eInstallationofbattsordensepack4.1301.10f Installationofrigidinsulation4.130.10g Installationofspraypolyurethanefoam(SPF)4.1301.10hInstallation,ifmechanicalsinjoistedassemblies(appliestoallinsulationtypes)4.1301.10i Securebatts4.1301.10j Rigidprotectivebarrier4.1301.10kPropertymanagereducation4.16 Ducts4.1601 InsulatingDucts4.1601.6 InsulatingMetalDucts—LowRise4.1601.6a Selectionofductinsulationmaterial4.1601.6b Ductsealing4.1601.6c Attachmentofductinsulation4.1601.6d Sealingoftheductinsulation
5 HeatingandCooling5.30 ForcedAir5.3001 Design5.3001.4 EquipmentSelection—LowRise5.3001.4a Loadcalculation:heatlossorgain5.3001.4b Loadcalculation:designconditionsofsinglestageorsinglespeedequipment5.3001.4c Loadcalculation:designconditionsformultistage,variablespeedequipment5.3001.4d Equipmentselection:airconditioningandheatpumps5.3001.4e Equipmentselection:auxiliaryheatforheatpumps5.3001.4f Equipmentselection:furnaces5.3001.5 DuctworkandTerminationDesign—LowRise5.3001.5a Sizing5.3001.5b Airhandlertoreturnplenum5.3001.5c Airhandlertosupplyplenum5.3001.5d Buildingcavitiesusedasductwork5.3001.5e Reducers5.3001.5f Supplybranchrunouts5.3001.5g Boots5.3001.5h Supplyterminations5.3001.5i Returngrillesizing5.3001.5j Manualvolumedampers5.3001.5k Flexibleducts5.3001.5l Take-offs5.3001.5m Firedampers5.3002 SitePreparation5.3002.2 SequenceofOperation—LowRise5.3002.2a Verification5.3002.4 PreparationforNewEquipment—LowRise5.3002.4a Access5.3002.4b Environmentalhazards5.3002.4c Disconnectionofutilities5.3002.4d Refrigerantrecovery5.3002.4e Disconnectionofequipment5.3002.4f Removal5.3002.7 SettingofAirHandler—LowRise5.3002.7a Location5.3002.7b Clearance5.3002.7c Connections5.3002.7d Support:horizontalairflow,attic5.3002.7e Support:horizontalairflow,basement,orcrawlspace5.3002.7f Support:upflowonaplatform5.3002.7g Support:downflow5.3002.7h Sealing5.3002.7i Drainage5.3003 SystemAssessmentandMaintenance5.3003.17 DataPlateVerification—LowRise5.3003.17aDataplateverification5.3003.18 LeakDetection—LowRise5.3003.18aCarbonmonoxide(CO)detection5.3003.18bGasleakdetection5.3003.18cFueloilleakdetection5.3003.19 RefrigerantLineInspection—LowRise5.3003.19aInsulation5.3003.19bUltraviolet(UV)protectionofinsulation5.3003.19cSizing5.3003.19dInstallationquality5.3003.19eSupport5.3003.20 ElectricalService—LowRise5.3003.20aPolarity5.3003.20bVoltage:incomingpower5.3003.20cWiresize5.3003.20dServicedisconnect5.3003.20eVoltage:contactor5.3003.20f Grounding5.3003.20gBloweramperage5.3003.20hCompressoramperage5.3003.20i Doorswitchoperation5.3003.20j Heatpump:emergencyheat5.3003.21 AirFlow—LowRise5.3003.21aValidateairdistributionsysteminstallation5.3003.21bTestingequipmentselection5.3003.21cTestairhandlerunit5.3003.21dTotalairflow
5.3003.21eExternalstaticpressure5.3003.21f Pressuredrop:coil5.3003.21gPressuredrop:filter5.3003.21hBalanceofroomflow:newductwork5.3003.21i Supplywetbulbanddrybulb5.3003.21j Returnwetbulbanddrybulb5.3003.21kTemperaturerise:gasandoilfurnacesonly5.3003.21l Finalbalance5.3003.21mOccupant/propertymanagereducation5.3003.22 CombustionAnalysis—LowRise5.3003.22aTestingequipmentselection5.3003.22bCombustionanalysisprotocol5.3003.22cOilsystem:nozzlesize5.3003.22dNaturalgas/propanesystem:burnerorifice(s)size5.3003.22eCombustionairadjustment5.3003.22f Fuelpressure/gaspressure5.3003.22hSteadystateefficiency(SSE)5.3003.22i Netstacktemperature5.3003.22j Carbondioxideandoxygen5.3003.22kExcessair5.3003.22l Carbonmonoxide(CO)influegas5.3003.24 EvaporativeCoolerMaintenanceandRepairs—LowRise5.3003.24aAssessmentanddiagnosis5.3003.24bRepairandmaintenance5.3003.24cOccupanteducation5.3003.34 FuelDeliverySystemforNaturalGasandPropane—LowRise5.3003.34aMaterialandsupport5.3003.34bSize5.3003.34cSealant5.3003.34dSafetydevicesforpropane5.3003.35 CombustionApplianceVentingSystem—LowRise5.3003.35aCombustionair5.3003.35bFlueventmaterial5.3003.35cInstallation5.3003.35dOrphanedequipment5.3003.36 DuctworkSystem—LowRise5.3003.36aLocation:indoor(supplyducts)ductsectionlocatedcompletelywithinthethermalboundaryofthebuilding5.3003.36bLocation:outdoorsductsectionlocatedoutsideofthethermalboundaryofthebuildingorinquasi-conditionedspaces5.3003.36cBuildingcavitiesusedasductwork5.3003.36dFirerating5.3003.36ePenetrations5.3003.36f Support5.3003.36gProtection5.3003.36hFastening:metaltoflexibleduct5.3003.36i Fastening:metaltometal5.3003.36j Fastening:ductboardtometal5.3003.36kFastening:boottobuildingconnection5.3003.36l Terminations5.3003.36mFiltration5.3003.36nExternalstaticpressure5.3003.36oAirflow:coolingandheatpumpsystems5.3003.36pTemperaturerise:heating-onlysystems5.3003.36qSystemprotectionduringconstructionandrenovation5.3003.36r Roompressurebalancing5.3003.36s Sealing:newductwork5.3003.36t Sealing:existingductwork5.3003.37 HeatingandCoolingControls—LowRise5.3003.37aRemovalofmercury-basedthermostats5.3003.37bRemovalofexistingcontrols5.3003.37cPenetrations5.3003.37dThermostatlocation5.3003.37eBlowerspeed5.3003.37f Thermostatselection:heatpump5.3003.37gHeatpump:supplementaryheat5.3003.37hHeatpump:outdoortemperaturesensor5.3003.37i Heatpump:supplementaryheatcontrolwiring5.3003.37j Thermostat:installerprogramming5.3003.37kTimedelaysettings5.3003.37l Humidistat:location5.3003.37mOccupanteducation5.3003.37nCentralcontroller5.3003.38 CondensateDrainageofHeatingandAirConditioningEquipment—LowRise5.3003.38aConnection
5.3003.38bInsulation5.3003.38cOverflowprotection:upflow5.3003.38dPumps5.3003.38eVentsandtraps5.3003.38f Drainpan5.3003.38gWaterleveldetectiondevice5.3003.38hTermination5.3088 SpecialConsiderations5.3088.2 RegionalClimaticConsiderations5.3088.2a Verycold5.3088.2b Cold5.3088.2c Mixedhumid5.3088.2d Hothumid5.3088.2e Marine5.3088.2f Hotdry5.3088.3 RegionalClimaticConsiderations—MidandHighRise5.3088.3a Verycold5.3088.3b Cold5.3088.3c Mixedhumid5.3088.3d Hothumid5.3088.3f Hotdry5.31 HydronicHeating(HotWaterandSteam)5.3102 EquipmentInstallation5.3102.2 VentingSealedCombustionAppliance5.3102.2a Flueventmaterialselection5.3102.2b Locationofventtermination5.3102.2c Locationofventingpath5.3102.2d Connectionpoints/joints5.3102.2e Pitchofflueconnection5.3102.14 ExpansionTankInstallation(HotWater)5.3102.14aCheckforpresenceofasbestos-containingmaterials(ACMs)5.3102.14bSizetank5.3102.14cIsolateinstallationlocation5.3102.14dInstalltank5.3102.14ePressurizetank5.3102.14f Reinsulatearea5.3102.14gEducation5.3102.15 Bladder-TypeExpansionTankPressurization(HotWater)5.3102.15aCheckforpresenceofasbestos-containingmaterials(ACMs)5.3102.15bIsolateexpansiontank5.3102.15cRepressurizetank5.3102.15dEducation5.3102.18 FlueGasCondensateTreatment—Condensing5.3102.18aFluecondensatedrainage5.3102.18bConnection5.3102.18cPumps5.3102.18dVentsandtraps5.3102.18eTermination5.3102.18f Floordrains5.3102.18gNeutralizationkit5.3102.18hPipingmaterial5.3102.18i Education5.3102.28 Burners5.3102.28aAssessment5.3102.28bService,upgrade,orreplaceburner5.3102.28cCombustionefficiency5.3102.28dModulation5.3102.28eEducation5.3102.28f Startup5.3102.28gFuel5.3102.30 Controls—EnergyManagementSystems5.3102.30aHazardousmaterials5.3102.30bAssessmentandverification5.3102.30cInstallationofanenergymanagementsystem(EMS)5.3102.30dTestingandverification5.3102.30eEducation5.3102.37 Controls—ThermostatReplacement5.3102.37aVisualinspection5.3102.37bMercuryassessment5.3102.37cInstallation5.3102.37dTesting5.3102.37eDisposal5.3102.37f Education
5.3102.38 FullCommissioning5.3102.38aCommissioningteam5.3102.38bDesignintentandapproach5.3102.38cDesignreview5.3102.38dSubmittals5.3102.38ePre-functionalchecklist5.3102.38f Functionaltest5.3102.38gDocuments5.3102.38hEducation5.3102.38i Nearendofwarrantysitevisit5.3104 EquipmentMaintenance,Testing,andRepair5.3104.12 LeakDetectionandRepair—DistributionLeaks5.3014.12dTestingandverification5.33 Non-DistributionCoolingSystems5.3302 RoomAirConditioners5.3302.1 Through-WallandRoomAirConditioningUnitReplacement5.3302.1a Assessment5.3302.1b Selection5.3302.1c Installation5.3302.1d Decommissioning5.3302.1e Staffeducation5.3302.1f Occupanteducation6 Ventilation6.60 Exhaust6.6004 ExhaustVentilationSystems6.6004.2 IndividualExhaustFanServingMultipleRoomsWithinSingleDwellingUnit(AllBuildingTypes)6.6004.2a Pre-inspection6.6004.2b Airflow6.6004.2c Outlettermination6.6004.2d Wiring6.6004.2e Access6.6004.2f Fanmounting6.6004.2g Backdraftdampers(requiredinintermittentsystems)6.6004.2h Combiningintakeducts6.6004.2i Ductconnections6.6004.2j Insulation6.6004.2k Boottointeriorsurfaceseal6.6004.2l Preventingairleakagecausedbyexhaustfans6.6004.2m Balanceandflow6.6004.2n Combustionzonetesting6.6004.2o Firedampers6.6004.2p Occupant/propertymanagereducation6.6005 ApplianceExhaustVents6.6005.4 KitchenRangeHoodwithinDwellingUnit(AllBuildingTypes)6.6005.4a Pre-inspection6.6005.4b Wiring6.6005.4c Fanselection/specification6.6005.4d Fanventing6.6005.4e Fanducting6.6005.4f Terminationfitting6.6005.4g Makeupair6.6005.4h Verification6.6005.4i Combustionzonetesting6.6005.4j Occupant/propertymanagereducation6.6088 SpecialConsiderations6.6088.1 RegionalClimaticConsiderations6.6088.1a Verycold6.6088.1b Cold6.61 Supply6.6102 Components6.6102.6 Intakes6.6102.6a Holeinbuildingshell6.6102.6b Intakefitting6.6102.6c Occupanteducation6.6102.6d Damper(ifapplicable)6.6102.6e Connectiontointakefitting6.6102.6f Weatherproofing6.6102.6g Pestexclusion6.6102.6h Intakelocation
6.62 WholeBuildingVentilation6.6202 Components6.6202.4 OperationalControls6.6202.4a Primaryventilationfan6.6202.4b Spotfan6.6202.4c Wiring6.6202.4d Occupancysensors/humidistat6.6202.4e Carbondioxidesensors(demandcontrol)6.6202.4f Occupant/propertymanagereducation7 Baseload7.80 PlugLoad7.8001 Refrigerators/Freezers7.8001.3 RefrigeratorandFreezerReplacement7.8001.3a Assessment7.8001.3b Selection7.8001.3c Installation7.8001.3d Commissioning7.8001.3e Decommissioning7.8001.3f Safety7.8001.3g Staffeducation7.8001.3h Occupanteducation7.8003 Lighting7.8003.11 LampReplacement7.8003.11aAssessment7.8003.11bSelection7.8003.11cInstallation7.8003.11dCommissioning7.8003.11eDecommissioning7.8003.11f Safety7.8003.11gStaffeducation7.8003.11hOccupanteducation7.81 WaterHeating7.8101 WaterUseReduction7.8101.2 Low-FlowRetrofitDevices7.8101.2a Removal7.8101.2b Installation7.8101.2c Commissioning7.8102 InstallationandReplacement7.8102.4 StorageTank-TypeWaterHeater7.8102.4a Hazardousmaterialremoval7.8102.4b Decommissioning7.8102.4c Newequipmentinstallation7.8102.4d Emergencydrainpan7.8102.4e Expansiontank7.8102.4f Temperatureandpressurereliefvalve7.8102.4g Dielectricunions(dielectricinsulator)7.8102.4h Backflowprevention7.8102.4i Thermalefficiencyandinsulation7.8102.4j Requiredcombustionair7.8102.4k Ventingoffluegases7.8102.4l Combustiontesting7.8102.4m Fuelsupply7.8102.4n Dischargewatertemperature7.8102.4o Commissioningofsystem7.8102.4p Occupanthealthandsafety7.8102.4q Occupanteducation7.8103 Maintenance/Inspection7.8103.7 CrossoverDuetoaBackflowintotheColdWaterSupply7.8103.7a Hazardousmaterialremoval7.8103.7b Installation7.8103.7c Commissioning7.8104 Distribution7.8104.8 DomesticHotWaterExpansionTank(PotableWater)7.8104.8a Adequateairpressureofexistingairtank7.8104.8b Propersizingofnewexpansiontank7.8104.8c Prechargeairpressureinnewexpansiontank7.8104.8d Newinstallationlocationofexpansiontank7.88 Baseload—SpecialConsiderations7.8801 Elevators
7.8801.1 ReplacementandMaintenance7.8801.1a Inspection7.8801.1b Energyefficiency7.8801.1c Installationandmaintenance
HealthandSafety>SafeWorkPractices>SafeWorkPractices
2.0100.1-GlobalWorkerSafetyDesiredOutcome:Workcompletedsafelywithoutinjuryorhazardousexposure
Note:Theauthorityhavingjurisdictionmayrequirethatalicensedprofessionalperformcertaintasksoutlinedinthisdetail.
HealthandSafety>SafeWorkPractices>SafeWorkPractices2.0100.1b-Handprotection
2.0100.1b-HandprotectionDesiredOutcome:Workcompletedsafelywithoutinjuryorhazardousexposure
Specification(s):Durableandwrist-protectinggloveswillbewornthatcanwithstandworkactivity
Objective(s):Minimizeskincontactwithcontaminants
Protecthandsfromhazards
HealthandSafety>SafeWorkPractices>SafeWorkPractices
2.0100.2-WorkAreaInspectionandStabilizationDesiredOutcome:Provideasafeandstableworkenvironmentthatwillsupportandsustainworktobeperformed
HealthandSafety>SafeWorkPractices>SafeWorkPractices2.0100.2c-Identifyenvironmentalconditionsthatmaycreateorworsenunsafeorunstablebuildingassembly
conditions
2.0100.2c-IdentifyenvironmentalconditionsthatmaycreateorworsenunsafeorunstablebuildingassemblyconditionsDesiredOutcome:Provideasafeandstableworkenvironmentthatwillsupportandsustainworktobeperformed
Specification(s):Theinspectionwillincludedeterminationofthepresenceofadverseenvironmentalconditions,includingexcessmoistureincontactwithbuildingassemblies,mold,wood-decayingfungi,androdentorinsectinfestation
Avisualinspectionofexposedelectricalwires,junctionboxes,andrelatedequipmentwillbemadetoidentifyanyunsafeconditions
Whereinsulationmaterialswillbedeliveredintoclosedcavities,evaluationofwiringtypeswithinsuchcavitieswillbeconductedtodetermineifproposedinsulationapplicationiscompatiblewithcurrentperformancecharacteristicsofwiring(e.g.,wiringtypesthatpresentafirehazardwheninclosecontactwithinsulationmaterials,wiringtypessubjecttocorrosionwhenincontactwithcertaintypesofinsulationorwhichmaybeadverselyaffectedbyheat,moisture,orprocessconditionsassociatedwiththeinstallationofcertaininsulationtypes)
Objective(s):Ensureadverseenvironmentalconditionsdonotcompromisethestabilityorlongevityofproposedwork
Ensuretheintegrityandsoundnessofbuildingassemblies
Preservethesafetyandintegrityofexistingbuildingassembliesandmaterialsafterinstallationofproposedimprovements
HealthandSafety>SafeWorkPractices>SafeWorkPractices2.0100.2d-Addressandcorrecthazardousoradverseconditions
2.0100.2d-AddressandcorrecthazardousoradverseconditionsDesiredOutcome:Provideasafeandstableworkenvironmentthatwillsupportandsustainworktobeperformed
Specification(s):Whereexcessmoistureconditionsareidentifiedwheretheircorrectionisnotincludedinproposedwork,suchconditionswillbecorrectedbeforeworkbegins
Wherebuildingassembliesorcomponentsarefoundtohavebeendamagedordestroyed,suchassemblieswillberestoredbeforeorduringproposedwork
Whereindicationsofrodentinfestationareidentified,airsealingmaterialswillincorporateanti-gnawingmeasure(e.g.,copperwoolin-fill,metalsheeting)
Whenpestshavebeenidentified,followintegratedpestmanagementpracticestosealholeswithpestproofmaterials(corrosionproofmaterials)
Objective(s):
Ensurethesafetyanddurabilityoftheassociatedstructures
Ensureproposedworkwillnotcauseorperpetuateunsafeorunhealthybuildingconditions
HealthandSafety>SafeWorkPractices>AirSealing
2.0101.1-AirSealingWorkerSafetyDesiredOutcome:Workcompletedsafelywithoutinjuryorhazardousexposure
HealthandSafety>SafeWorkPractices>AirSealing2.0101.1a-Workersafety
2.0101.1a-WorkersafetyDesiredOutcome:Workcompletedsafelywithoutinjuryorhazardousexposure
Specification(s):WorkersafetyspecificationswillbeinaccordancewithSWSGlobalWorkerSafety
Completesafetyactionplanbasedonhazard;planwillbeinplaceforeachjobsite
Objective(s):Preventinjury
Minimizeexposuretohealthandsafetyhazards
HealthandSafety>SafeWorkPractices>AirSealing2.0101.1b-Moistureprecautionsforcrawlspacesandbasements
2.0101.1b-MoistureprecautionsforcrawlspacesandbasementsDesiredOutcome:Workcompletedsafelywithoutinjuryorhazardousexposure
Specification(s):Exposedearthwillbecoveredwithacontinuous,durable,andsealedclassIvaporretarderthatissuitableforgroundcontactexposuretonormalservicetraffic
Causesofairdewpointsgreaterthan55°Fwillbeidentifiedandeliminatedincrawlspacesconnectedtoconditionedspaces
Seasonaldehumidification(e.g.,dehumidifiedorconditionedwithairconditionersupply)willberecommendedwherehumiditysources,includingoutdoorairincursion,cannotbeeliminated
Undesignedpenetrationsbetweenthecrawlspaceorbasementandtheoutdoorswillbesealed
Holesbetweenthecrawlspaceorbasementandthelivingspacewillbesealed
Opensumpsandintentionalslaborvaporbarrierpenetrationswillbesealedorcappedtocontrolmoistureandradonlevels
Objective(s):Ensuredurabilityofrepairs
Reducepotentialforoccupantexposuretomoldandothermoisture-relatedhazards
Reducepotentialforoccupantexposuretoradonandothersoilgases
HealthandSafety>SafeWorkPractices>AirSealing2.0101.1c-Moistureprecautions:livingspace
2.0101.1c-Moistureprecautions:livingspaceDesiredOutcome:Workcompletedsafelywithoutinjuryorhazardousexposure
Specification(s):Moisturesourcesinthebuildingwillbeidentifiedandreducedorremoved
Wherelocalventilationwillbeinstalled,(e.g.,baths,kitchens),exhaustunitswillbeventedtotheoutdoorsinaccordancewithASHRAE62.2
UnventedheaterswillberemovedexceptwhenusedasasecondaryheatsourceandwhenitcanbeconfirmedthattheunitislistedtoANSIZ21.11.2
Unventedgasorpropanecookingstoveswillbetestedforcarbonmonoxide(CO)perBPIStandardandcorrectedasrequiredbeforeairsealingworkbegins
Ifreplacingairconditioningsystem,newsystemwillbesizedtooptimizedehumidification
Properlysizeddehumidifierwillbeinstalledtosatisfylatentandsensibleloads,whennecessary
ANSI/ACCA2ManualJ-2011(ResidentialLoadCalculation)willbeusedtosizereplacementACandheatpumps
EnhanceddehumidificationwillbeinstalledintheGulfCoastregionareasontheGulfsideofthewarmhumidlineontheInternationalEnergyConservationCodemap
Objective(s):Ensuredurabilityofbuildingcomponentsandrepairs
Reducepotentialforoccupantexposuretomoldandothermoisture-relatedhazards
ReducepotentialoccupantexposuretoCO
HealthandSafety>SafeWorkPractices>AirSealing2.0101.1d-Moistureprecautionsforexteriorwater
2.0101.1d-MoistureprecautionsforexteriorwaterDesiredOutcome:Workcompletedsafelywithoutinjuryorhazardousexposure
Specification(s):Beforeairsealingandinsulatingbuildingcomponents,exteriorwatermanagementwillbeaddressed
Beforeinsulatingbasementorcrawlspacewallsnearwetareas,surfacewaterpoolingnearthefoundationwillbeaddressedbyrepairing,modifying,orreplacingguttersanddownspouts
Gradingandsubsurfacedrainageatcriticallocations(e.g.,localizeddrainandgradingbeneathvalleys)willbeinaccordancewithEPAIndoorairPLUSConstructionSpecificationsSection1.1
Objective(s):Reducepotentialforoccupantexposuretomoldandothermoisture-relatedhazards
HealthandSafety>SafeWorkPractices>Baseload
2.0105.2-LicensedElectricalProfessionalDesiredOutcome:Workcompletedsafelywithoutinjuryfromshockorarcflash
HealthandSafety>SafeWorkPractices>Baseload2.0105.2a-Workersafety
2.0105.2a-WorkersafetyDesiredOutcome:Workcompletedsafelywithoutinjuryfromshockorarcflash
Specification(s):Anyfixture,ballast,linevoltagecontrol,receptacle,orcircuitmodificationwillbeperformedbyalicensedelectricalprofessionalinaccordancewithANSI/NFPA70orasrequiredbytheauthorityhavingjurisdiction
AllworkerswillcomplywithANSI/NFPA70E
AllOSHAstandardpracticeswillbefollowed
Objective(s):Preventpropertydamage
Ensureworkersafety
HealthandSafety>SafeWorkPractices>MaterialSafety
2.0106.2-PotentialAsbestos-ContainingMaterialsDesiredOutcome:WorkwithpropertymanagerstoensureAsbestosContainingMaterials(ACMs)aretreatedproperly
Note:Theauthorityhavingjurisdictionmayrequirethatalicensedprofessionalperformcertaintasksoutlinedinthisdetail.
HealthandSafety>SafeWorkPractices>MaterialSafety2.0106.2a-Determineiftestingisnecessary
2.0106.2a-DetermineiftestingisnecessaryDesiredOutcome:WorkwithpropertymanagerstoensureAsbestosContainingMaterials(ACMs)aretreatedproperly
Specification(s):Existinginsulationwillbevisuallyinspectedwithoutdisturbingthematerialandevaluatedforsuspicionofasbestos-containingmaterials(ACM)
Propertymanagerwillbeaskedaboutknownhistoryofinsulation
Propertymanagerwillbeinformedofpotentialforadditionaltestingifhistoryisunknown
Objective(s):ConfirmlikelihoodofACMs
HealthandSafety>SafeWorkPractices>MaterialSafety2.0106.2b-IfACMmaybepresent,educatepropertymanagerforneedoftesting
2.0106.2b-IfACMmaybepresent,educatepropertymanagerforneedoftestingDesiredOutcome:WorkwithpropertymanagerstoensureAsbestosContainingMaterials(ACMs)aretreatedproperly
Specification(s):Environmentaltestingservicewillberetainedandnotifiedofareaimpactedbyproposedwork
Objective(s):ConfirmpresenceofACMs
HealthandSafety>CombustionSafety>VentedGasAppliances
2.0203.3-CombustionAir—BoilersDesiredOutcome:Amountandqualityofcombustionairallowsforsafeandefficientoperationofequipment
HealthandSafety>CombustionSafety>VentedGasAppliances2.0203.3a-Combustionair
2.0203.3a-CombustionairDesiredOutcome:Amountandqualityofcombustionairallowsforsafeandefficientoperationofequipment
Specification(s):Combustionairshallbecalculatedandprovidedinconformancewiththeapplicablecodeadoptedbythejurisdictionandmanufacturerrequirements
Ininstanceswhereconflictsoccurbetweenthecodeandthemanufacturer'sinstallationinstructions,themorerestrictiveprovisionsshallapply(i.e.,moreairratherthanless)
Inabsenceofalocalcode,combustionairshallbecalculatedandprovidedinconformancewithanyofthefollowing:NFPA54,IFGC,orNFPA31.
Exception:ExistingappliancesthathavepassedcombustionsafetytestingusingtheproceduresofBPI1200aredeemedtohavesufficientcombustionair.
Objective(s):Meetburnercombustionairrequirements
HealthandSafety>CombustionSafety>VentedGasAppliances2.0203.3b-Education
2.0203.3b-EducationDesiredOutcome:Amountandqualityofcombustionairallowsforsafeandefficientoperationofequipment
Specification(s):Propertymanager/occupantwillbeeducatedonproperoperationofcombustionairsystems
Objective(s):Ensureoccupantsafety
Ensureoptimaloperationofequipment
HealthandSafety>CombustionSafety>Isolation
2.0204.2-IsolatingCombustionApplianceRooms(e.g.,BoilerRoom,FurnaceRoom,andGeneratorRoom)DesiredOutcome:Effectiveairbarrierbetweenthecombustionapplianceroomandallotherspacesofthebuilding
Note:
HealthandSafety>CombustionSafety>Isolation2.0204.2a-Pre-inspection
2.0204.2a-Pre-inspectionDesiredOutcome:Effectiveairbarrierbetweenthecombustionapplianceroomandallotherspacesofthebuilding
Specification(s):Hazardousmaterialsstoredinmechanicalroomswithairhandlersorcombustionappliances(e.g.,boilers,furnaces)willbeidentifiedandremoved;operatorswillbeeducatedonthedangersofstoringhazardousmaterialsintheseareas
Repairsnecessarytostabilizeworkareasandprotectorpreserveintegrityofenergyimprovementwillbecompletedbeforesubjectworkbegins
Mechanicalroomdoorsinafire-ratedwallwillbeclosed;problemsthatcausedoorstobeblockedopenwillbedeterminedandresolved
Objective(s):Eliminateexistingstoragehazardsandpreventfuturedangerousstorageoccurrences
Repairoraddressmoisture,pest,andstructure-relatedissues
Provideasafeandstableworkenvironment
HealthandSafety>CombustionSafety>Isolation2.0204.2b-Identificationofpenetrations
2.0204.2b-IdentificationofpenetrationsDesiredOutcome:Effectiveairbarrierbetweenthecombustionapplianceroomandallotherspacesofthebuilding
Specification(s):Penetrationswillbeidentifiedusingvisualinspections,infraredthermography,smoke,and/orpressuretests[ASTME1186-03(2009)]
Objective(s):Locateairleakagepathwaystorepair
HealthandSafety>CombustionSafety>Isolation2.0204.2c-Preparation
2.0204.2c-Preparation
DesiredOutcome:Effectiveairbarrierbetweenthecombustionapplianceroomandallotherspacesofthebuilding
Specification(s):Healthandsafetyconcernswillbeaddressedforoccupants,workers,andrepairmaterialsinaccordancewithOSHAstandards(OSHA1926,1910)
Theareawillbepreparedandisolatedinaccordancewithhealthandsafetystandardsfortheapplicationandmaterials(e.g.,extremetemperatures,lead,asbestos,carbonmonoxide)
Worklighting,workplatform,andadequateventilationwillbeprovided
Objective(s):Provideasafeworkenvironment
Provideasafeindoorenvironmentalquality(IEQ)workenvironment
Provideeffectiverepairaccess
HealthandSafety>CombustionSafety>Isolation2.0204.2d-Sealantandmaterialsselection
2.0204.2d-SealantandmaterialsselectionDesiredOutcome:Effectiveairbarrierbetweenthecombustionapplianceroomandallotherspacesofthebuilding
Specification(s):Sealantsandmaterialswillbecompatiblewiththeirintendedsurfacesandappliedinaccordancewithmanufacturerspecifications
Selectionwillbedurable,pestresistant,andhaveaweather-appropriateseal
IndoorsealantswillbelowVOCproductsthatmeetindependenttestingandverificationprotocols,suchasGreenSealGS-36,"GREENGUARDChildrenandSchools,"orcomparablecertifications
Fire-ratedassemblieswillbesealedbyqualifiedworkers,usingmaterialsandsealantspermittedbytheauthorityhavingjurisdiction,andinaccordancewithadoptedbuildingcodes
Mechanicalandboilerroomenclosuresmayneedtobefire-ratedassembliesMaterialswillberatedforapplicationinapproveddetails;forexample,theannularspacearoundapipepenetrationthroughafire-ratedwallcanusuallybesealedusingmineralwoolfiresafingsealedwithacoatingofflexiblefiredammaterial
Sealantsandmaterialswillbecontinuousandmeetfireresistanceratedassemblyspecifications
Objective(s):Ensuresealantsandmaterialsmeetorexceedtheperformancecharacteristicsrequiredoftheassembly(e.g.,firerating)
Preventintrusionofmoistureandpestsintothesealedassembly
PreventexposingworkersoroccupantstoexcessiveVOClevels
Provideadurableandeffectiveisolationoftheidentifiedcompartmentalizedspace
HealthandSafety>CombustionSafety>Isolation2.0204.2e-Verification
2.0204.2e-VerificationDesiredOutcome:
Effectiveairbarrierbetweenthecombustionapplianceroomandallotherspacesofthebuilding
Specification(s):Repairswillbeverifiedusingvisualinspections,infraredthermography,smoke,and/orpressuretests[ASTME1186-03(2009)]
Objective(s):Ensurequalityandeffectivenessofairsealing
HealthandSafety>CombustionSafety>GasandOil-FiredEquipment
2.0205.1-GasandOil-FiredEquipmentDesiredOutcome:Combustionproductsareproperlyventedtotheoutdoors
Note:
HealthandSafety>CombustionSafety>GasandOil-FiredEquipment2.0205.1a-Combustionair
2.0205.1a-CombustionairDesiredOutcome:Combustionproductsareproperlyventedtotheoutdoors
Specification(s):Combustionairshallbecalculatedandprovidedinconformancewiththeapplicablecodeadoptedbythejurisdiction,andmanufacturerinstallationrequirements
Ininstanceswhereconflictsoccurbetweenthecodeandthemanufacturer'sinstallationinstructions,themorerestrictiveprovisionsshallapply
Inabsenceofalocalcode,combustionairshallbecalculatedandprovidedinconformancewithanyofthefollowing:NFPA54,IFGC,orNFPA31
Objective(s):Donotdamagebuilding
Protectworkersandoccupantsfrominjury
HealthandSafety>CombustionSafety>GasandOil-FiredEquipment2.0205.1b-Installation
2.0205.1b-InstallationDesiredOutcome:Combustionproductsareproperlyventedtotheoutdoors
Specification(s):Ventingsystemswillbeinstalledconsideringpropermaterial,pitch,commonventing,chimneyliner,clearance,totalequivalentlength,andterminationinaccordancewiththeapplicablecodeadoptedbythejurisdictionandmanufacturerinstallationrequirements
Ininstanceswhereconflictsoccurbetweenthecodeandthemanufacturer'sinstallationinstructions,themorerestrictiveprovisionsshallapply
Inabsenceoflocalcode,combustionbyproductsshallberemovedinaccordancewithanyofthefollowing:NFPA54,IFGC,orNFPA31
Objective(s):Exhaustcombustionproductstotheoutdoors
Protectbuildingfromdamage
Protectworkersandoccupantsfrominjury
HealthandSafety>CombustionSafety>GasandOil-FiredEquipment2.0205.1c-Orphanedequipment
2.0205.1c-OrphanedequipmentDesiredOutcome:Combustionproductsareproperlyventedtotheoutdoors
Specification(s):Existingventsystemorchimneywillberesizedorrelinedinaccordancewiththeapplicablecodeadoptedbythejurisdictionwhenoneormorecommonventedappliancesareremoved
Inabsenceoflocalcode,combustionbyproductsshallberemovedinaccordancewithanyofthefollowing:NFPA54,IFGC,orNFPA31
Objective(s):Exhaustcombustionproductstotheoutdoors
Protectbuildingfromdamage
Protectworkersandoccupantsfrominjury
HealthandSafety>Radon>TestingandEvaluation
2.0502.1-RadonTestingandEvaluationDesiredOutcome:Workcompletedwithoutincreasingoccupantexposuretoradon
Note:
HealthandSafety>Radon>TestingandEvaluation2.0502.1a-Radontestingandmitigation
2.0502.1a-RadontestingandmitigationDesiredOutcome:Workcompletedwithoutincreasingoccupantexposuretoradon
Specification(s):EPAguidelinesforradonincurrenteditionof"HealthyIndoorEnvironmentProtocolsforHomeEnergyRetrofits"willbefollowed
Testwillbelimitedtoconditionedspaceswithslab-onorbelowgradeservingasfloor,orfloorimmediatelyabovebasementorcrawlspace
UpperfloorsinmultistorybuildingswithconcreteorconcretemasonryunitwallswillbetestedinaccordancewithAARSTstandards
Objective(s):Reducepotentialforoccupantexposuretoradon
HealthandSafety>OccupantEducationandAccess>InstalledEquipment
2.0702.2-OccupantEducationDesiredOutcome:Occupantsandbuildingoperationsstaffunderstandtheirroleandresponsibilityinthesafe,effective,andefficientoperationoftheequipment
HealthandSafety>OccupantEducationandAccess>InstalledEquipment2.0702.2a-Systemoperation
2.0702.2a-SystemoperationDesiredOutcome:Occupantsandbuildingoperationsstaffunderstandtheirroleandresponsibilityinthesafe,effective,andefficientoperationoftheequipment
Specification(s):Basicoperationoftheequipmentwillbeexplainedtothebuildingoperationsstaff(e.g.,designconditions,efficiencymeasures,differencesfromprevioussystemorsituation)
Objective(s):Ensureoccupantsandbuildingoperationsstaffhaveareasonableexpectationoftheequipmentcapability
HealthandSafety>OccupantEducationandAccess>InstalledEquipment2.0702.2b-Systemcontrols(e.g.,thermostat,humidistat)
2.0702.2b-Systemcontrols(e.g.,thermostat,humidistat)DesiredOutcome:Occupantsandbuildingoperationsstaffunderstandtheirroleandresponsibilityinthesafe,effective,andefficientoperationoftheequipment
Specification(s):Properoperationandprogrammingofsystemcontrolstoachievetemperatureandhumiditycontrolwillbeexplainedtotheoccupantandprovidedinawrittenformat
Objective(s):Ensureoccupantsandbuildingoperationsstaffcanoperatesystemcontrols
HealthandSafety>OccupantEducationandAccess>InstalledEquipment2.0702.2c-Systemdisconnects
2.0702.2c-SystemdisconnectsDesiredOutcome:Occupantsandbuildingoperationsstaffunderstandtheirroleandresponsibilityinthesafe,effective,andefficientoperationoftheequipment
Specification(s):Indoorandoutdoorelectricaldisconnectsandfuelshutoffswillbedemonstratedtooccupant
Objective(s):Ensureoccupantsandbuildingoperationsstaffcanshutoffequipmentinemergencies
HealthandSafety>OccupantEducationandAccess>InstalledEquipment2.0702.2d-Combustionairinlets
2.0702.2d-CombustionairinletsDesiredOutcome:Occupantsandbuildingoperationsstaffunderstandtheirroleandresponsibilityinthesafe,effective,andefficientoperationoftheequipment
Specification(s):Locationofcombustionairinletswillbeidentifiedforoccupant
Importanceofnotblockinginletswillbeexplainedtooccupant
Objective(s):Ensureoccupantsandbuildingoperationsstaffdonotblockcombustionairinlets
HealthandSafety>OccupantEducationandAccess>InstalledEquipment2.0702.2e-Blockedairflow
2.0702.2e-BlockedairflowDesiredOutcome:Occupantsandbuildingoperationsstaffunderstandtheirroleandresponsibilityinthesafe,effective,andefficientoperationoftheequipment
Specification(s):Importanceofcleaningdustanddebrisfromreturngrilleswillbeexplainedtooccupant
Properplacementofinteriorfurnishingswithrespecttoregisterswillbeexplainedtooccupant
Negativeconsequencesofclosingregisterswillbeexplainedtooccupant
Occupantwillbeeducatedontheimportanceofleavinginteriordoorsopenasmuchaspossible
Objective(s):Ensureoccupantsandbuildingoperationsstaffdonotpreventtheequipmentfromoperatingasdesigned
HealthandSafety>OccupantEducationandAccess>InstalledEquipment2.0702.2f-Routinemaintenance
2.0702.2f-RoutinemaintenanceDesiredOutcome:Occupantsandbuildingoperationsstaffunderstandtheirroleandresponsibilityinthesafe,effective,andefficientoperationoftheequipment
Specification(s):Properfilterselectionandhowtochangefilterwillbeexplainedtobuildingoperationsstaff
Importanceofkeepingoutdoorunitclearofdebris,vegetation,decks,andotherblockagewillbeexplainedtobuildingoperationsstaff
Importanceandtimingofroutineprofessionalmaintenancewillbeexplainedtobuildingoperationsstaff,e.g.inspect,clean,lubricate,replaceconsumables(i.e.,filters,belts,lights),repairandreplace
Objective(s):Ensureequipmentoperatesasdesigned
HealthandSafety>OccupantEducationandAccess>InstalledEquipment2.0702.2g-Occupantservicerequests
2.0702.2g-OccupantservicerequestsDesiredOutcome:Occupantsandbuildingoperationsstaffunderstandtheirroleandresponsibilityinthesafe,effective,andefficientoperationoftheequipment
Specification(s):Appropriatesituationsofwhentheoccupantshouldcontactthebuildingoperationsstaffwillbeexplained,including:
FuelodorsWaterdrainingfromsecondarydrainlineEmergencyheatindicatoralwaysonforaheatpumpsystemSystemblowingcoldairduringheatingseasonandviceversaIcingoftheevaporatorcoilduringcoolingmodeOutdoorunitneverdefrostsUnusualnoisesUnusualodors
Objective(s):Occupantwillcontactbuildingoperationsstaffwhensystemisnotoperatingasdesigned
HealthandSafety>OccupantEducationandAccess>InstalledEquipment2.0702.2h-Carbonmonoxide(CO)
2.0702.2h-Carbonmonoxide(CO)DesiredOutcome:Occupantsandbuildingoperationsstaffunderstandtheirroleandresponsibilityinthesafe,effective,andefficientoperationoftheequipment
Specification(s):OccupantwillbeinformedaboutCOalarms
Objective(s):Protectoccupantsfrominjury
HealthandSafety>OccupantEducationandAccess>InstalledEquipment2.0702.2i-Warrantyandservice
2.0702.2i-WarrantyandserviceDesiredOutcome:Occupantsandbuildingoperationsstaffunderstandtheirroleandresponsibilityinthesafe,effective,andefficientoperationoftheequipment
Specification(s):Buildingoperationsstaff/propertymanagerwillbeprovidedwithrelevantmanualsandwarranties
Thelaborwarrantywillbeexplained,andthebuildingoperationsstaffwillbegivenaphonenumbertocallforwarrantyservice
Objective(s):Buildingstaffareequippedwithmanualsandwarrantiesforfutureequipmentservicing
HealthandSafety>OccupantEducationandAccess>Insulation
2.0703.1-Sealing/IsolatingExposedFibrousInsulationinAreaswithRoutineHumanActivityDesiredOutcome:Occupantsprotectedfrominsulationparticulateexposure
Note:
HealthandSafety>OccupantEducationandAccess>Insulation2.0703.1a-FibrousInsulationIsolation
2.0703.1a-FibrousInsulationIsolationDesiredOutcome:Occupantsprotectedfrominsulationparticulateexposure
Specification(s):Fibrousinsulationmaterialswillbeencapsulatedonallsurfacesfacingspaceswherethereisroutinehumanactivity
Encapsulationmaterialswillbefirerated,ifapplicable,topreservethepre-retrofitfireratingofthebuildingassembly,and/orasrequiredbyinsulationmanufacturerorrelevantbuildingcode
Vaporpermeabilityofencapsulationmaterialswillbeconsistentwithpredeterminedvaporretarderplacement
Objective(s):Protectoccupantsfrominsulationexposure
Maintainfireratingofassembly
Protectbuildingfrommoisturedamage
AirSealing>Attics>PenetrationsandChases
3.1001.5-PenetrationsandChasesDesiredOutcome:Penetrationsandchasessealedtopreventairleakageandmoisturemovementbetweentheatticandconditionedspace
Note:
AirSealing>Attics>PenetrationsandChases3.1001.5a-Pre-inspection
3.1001.5a-Pre-inspectionDesiredOutcome:Penetrationsandchasessealedtopreventairleakageandmoisturemovementbetweentheatticandconditionedspace
Specification(s):Gaps,cracks,andholesinfireseparationslocatedwithintheworkareawillbevisuallyidentifiedandincorporatedintoairsealingworkscope,includingthosethatspantwoconditionedorunconditionedspaces
Wheredrawingsareavailablethatidentifyspecificfire-resistanceratings(i.e.,1hour,2hour),materialsandmethodswillbeemployedtopreserveorrestoresuchrating
Wheredrawingsareunavailableordonotidentifyspecificfire-resistanceratings,thefire-resistanceratingoftheassemblymaybeinferredfromthecurrentconstruction(i.e.,single5/8sheetrock,concretemasonryunity),andmaterialsandmethodsemployedwillbeconsistentwithrestoringorpreservingsuchinferredfire-resistancerating
Objective(s):Ensureacontinuousairandfirebarrierwillbeappropriatelylocatedbetweenconditionedandunconditionedspace
AirSealing>Attics>PenetrationsandChases3.1001.5b-Backingandinfill
3.1001.5b-BackingandinfillDesiredOutcome:Penetrationsandchasessealedtopreventairleakageandmoisturemovementbetweentheatticandconditionedspace
Specification(s):Wheregaps,cracks,orholesarelargerthan1/4"acrossand/orwheretheairsealingmaterialswillbesubjecttotemperaturevariationsinexcessof50°F,theneedforbackingorinfillwillbeevaluated
Ifused,backingorinfillwillmeetspecificcharacteristicsofthefire-resistance-ratedassembly,andbecompatiblewiththecharacteristicsofthegap,crack,orhole,includingpreservationofanyexpansion/contractioncharacteristicsforassembly(e.g.,expansionjoints,steampipes,ordissimilarmaterialinterfaceswithdifferingcoefficientsofexpansion)
Backingorinfillwillbeselectedthatmaintainssealantplacementanddurabilitywhileallowingfortheexpectedmovementfromexpansion,contraction,loaddeflection,settlingatthelocation,orifexistingwatercontrolmeasuresarecompromised(e.g.,rainscreen,dripedge,weepholes,gutterandroofdrains,scuppers,orotherexteriorwatermanagementelements)
Objective(s):Minimizegaporholesizetoensuresuccessfuluseofsealant
Ensureclosureispermanentandsupportsappropriateload(e.g.,wind,snow,insulation)
Ensuresealantdoesnotfallout
Ensureintegrityoftheexistingwatercontrolsystem
AirSealing>Attics>PenetrationsandChases3.1001.5c-Sealantselection
3.1001.5c-SealantselectionDesiredOutcome:Penetrationsandchasessealedtopreventairleakageandmoisturemovementbetweentheatticandconditionedspace
Specification(s):Sealantswillbecompatiblewiththeirintendedsurfacesandappliedinaccordancewithmanufacturerspecifications
Selectionwillbedurable,pestresistant,andhaveaweather-appropriateseal
Indoorsealantswillbelowvolatileorganiccompound(VOC)productsthatmeetindependenttestingandverificationprotocols,suchasGreenSealGS-36,"GREENGUARDChildrenandSchools,"orcomparablecertifications
Fire-resistance-ratedassemblieswillbeprovidedwithsealantspermittedbytheauthorityhavingjurisdictionandadoptedbuildingcode
Objective(s):Preventintrusionofmoistureandpestsintothesealedassembly
PreventexposingworkersoroccupantstoexcessiveVOClevels
Ensuresealantmeetsorexceedstheperformancecharacteristicsoftheassemblyandiscompliantwithlocalfirecoderequirements
AirSealing>Attics>PenetrationsandChases3.1001.5d-Hightemperatureapplication
3.1001.5d-HightemperatureapplicationDesiredOutcome:Penetrationsandchasessealedtopreventairleakageandmoisturemovementbetweentheatticandconditionedspace
Specification(s):Onlynoncombustiblesealantwillbeusedincontactwithchimneys,ventsandflues,oranyheatsource(e.g.,non-IC-ratedrecessedlights,heatlamps,etc.)
Sealantapplicationatfactory-builtvents,flues,andchimneysshallbelistedforusewiththatventassembly
Objective(s):Preserveintegrityandanyapplicablewarrantyassociatedwithfactorybuiltvent,flue,orchimneyassemblies
AirSealing>Attics>PenetrationsandChases
3.1001.6-FirewallinUnconditionedAtticDesiredOutcome:Firewallseparationsinunconditionedatticssealedtopreventairleakage,moisturemovement,andspreadoffirebetweentheunconditionedatticandconditionedspace
Note:
AirSealing>Attics>PenetrationsandChases3.1001.6a-Pre-inspection
3.1001.6a-Pre-inspectionDesiredOutcome:Firewallseparationsinunconditionedatticssealedtopreventairleakage,moisturemovement,andspreadoffirebetweentheunconditionedatticandconditionedspace
Specification(s):Conductpre-inspectioninaccordancewithSWS2.0100.4WorkAreaInspectionandStabilization
Gaps,cracks,andholesinfireseparationslocatedwithintheworkareawillbevisuallyidentifiedandincorporatedintoairsealingworkscope,includingthosethatspantwoconditionedorunconditionedspaces.
Wheredrawingsareavailablethatidentifyspecificfire-resistanceratings(i.e.,1hour,2hour),materialsandmethodswillbeemployedtopreserveorrestoresuchrating
Wheredrawingsareunavailableordonotidentifyspecificfire-resistanceratings,thefire-resistanceratingoftheassemblymaybeinferredfromthecurrentconstruction(i.e.,single5/8sheetrock,concretemasonryunit),andmaterialsandmethodsemployedwillbeconsistentwithrestoringorpreservingsuchinferredfire-resistancerating
Airsealinglocationswillbeidentifiedbetweenthefirewallandtheatticfloor
Objective(s):Ensureacontinuousair-andfire-resistancebarrierwillbeappropriatelylocatedbetweenconditionedandunconditionedspace
AirSealing>Attics>PenetrationsandChases3.1001.6b-Backingandinfill
3.1001.6b-BackingandinfillDesiredOutcome:Firewallseparationsinunconditionedatticssealedtopreventairleakage,moisturemovement,andspreadoffirebetweentheunconditionedatticandconditionedspace
Specification(s):Wheregaps,cracks,orholesarelargerthan1/4"acrossand/orwheretheairsealingmaterialswillbesubjecttotemperaturevariationsinexcessof50°F,theneedforbackingorinfillwillbeevaluated
Ifused,backingorinfillwillmeetspecificcharacteristicsofthefire-resistance-ratedassemblyandbecompatiblewiththecharacteristicsofthegap,crack,orhole,includingpreservationofanyexpansion/contractioncharacteristicsforassembly(e.g.,expansionjoints,steampipes,ordissimilarmaterialinterfaceswithdifferingcoefficientsofexpansion)
Backingorinfillwillbeselectedthatmaintainssealantplacementanddurabilitywhileallowingfortheexpectedmovementfromexpansion,contraction,loaddeflection,settlingatthelocation,orifexistingwatercontrolmeasuresarecompromised(e.g.,rainscreen,dripedge,weepholes,gutterandroofdrains,scuppers,orotherexteriorwatermanagementelements)
Objective(s):Minimizegaporholesizetoensuresuccessfuluseofsealant
Ensureclosureispermanentandsupportsappropriateload(e.g.,wind,snow,insulation)
Ensuresealantdoesnotfallout
Ensureintegrityoftheexistingwatercontrolsystem
AirSealing>Attics>PenetrationsandChases3.1001.6c-Sealantselection
3.1001.6c-SealantselectionDesiredOutcome:Firewallseparationsinunconditionedatticssealedtopreventairleakage,moisturemovement,andspreadoffirebetweentheunconditionedatticandconditionedspace
Specification(s):Sealantswillbecompatiblewiththeirintendedsurfacesandappliedinaccordancewithmanufacturerspecifications
Selectionwillbedurable,pestresistant,andhaveaweather-appropriateseal
Indoorsealantswillbelowvolatileorganiccompounds(VOC)productsthatmeetindependenttestingandverificationprotocols,suchasGreenSealGS-36,"GREENGUARDChildrenandSchools,"orcomparablecertifications
Fire-resistance-ratedassemblieswillbeprovidedwithsealantspermittedbytheauthorityhavingjurisdictionandadoptedbuildingcode
Objective(s):Preventintrusionofmoistureandpestsintothesealedassembly
PreventexposingworkersoroccupantstoexcessiveVOClevels
Ensuresealantmeetsorexceedstheperformancecharacteristicsoftheassemblyandiscompliantwithlocalfirecoderequirements
AirSealing>Attics>PenetrationsandChases3.1001.6d-Jointseal
3.1001.6d-JointsealDesiredOutcome:Firewallseparationsinunconditionedatticssealedtopreventairleakage,moisturemovement,andspreadoffirebetweentheunconditionedatticandconditionedspace
Specification(s):Continuoussealwillbeinstalledaroundseams,cracks,joints,edges,penetrations,andconnectionsat:
TheintersectionbetweenfirewallandatticfloorIffirewallassemblyisnotmonolithic(e.g.,balloonframing,CMU,openchase,atticbypass,orwithsimilarpenetrationthroughtheatticfloorplane),atticfloorplanepenetrationswithinthefirewallassemblywillbeaccessedthroughthefirewall,fullysealed,andfirewallsurfacerestoredtopreventcurrentorfuturebreachesofthefirewallbelowtheatticfloorplanefromestablishinganairflowpathtotheatticspace
Objective(s):Provideairtight,durablesealthatdoesnotmove,bend,orsag
AirSealing>Attics>PenetrationsandChases
3.1001.8-PreparingforandInstallingInsulationAroundHigh-TemperatureDevices,Systems,andComponentsDesiredOutcome:Combustiblematerialskeptawayfromcombustionsources
Note:
AirSealing>Attics>PenetrationsandChases3.1001.8a-Pre-Inspection
3.1001.8a-Pre-InspectionDesiredOutcome:Combustiblematerialskeptawayfromcombustionsources
Specification(s):Conductpre-inspectioninaccordancewithSWS2.0100.4WorkAreaInspectionandStabilization
Confirmthatfluesorotherhigh-temperatureelementsarefunctioningasdesignedanddonotpresentafireorhealthandsafetyrisk
Objective(s):Ensureasafe,durableworkspacethatwillsustainimprovement
AirSealing>Attics>PenetrationsandChases3.1001.8b-Verifyatticprep
3.1001.8b-VerifyatticprepDesiredOutcome:Combustiblematerialskeptawayfromcombustionsources
Specification(s):Confirmthatonlynoncombustiblesealanthasbeenusedincontactwithchimneys,ventsandflues,oranyheatsource(e.g.,non-IC-ratedrecessedlights,heatlamps,etc.).Removeanynoncompliantmaterialsandreplacethemwithmaterialsconsistentwithapplication
Sealantapplicationatfactory-builtvents,flues,andchimneysshallbelistedforusewiththatventassembly
Fireblockinginthespacearoundsite-builtandfactory-builtchimneys,asrequiredbyeithertheIBC,IRC,orNFPA,asapplicable,willbecompletedandinspectedbeforeerectionofanyinsulationdams
Objective(s):Preventairleakage
Ensurematerialscomingincontactwithhigh-temperatureareaswillnotpresentafirehazard
Ensureinsulationdamsmaintainclearance
AirSealing>Attics>PenetrationsandChases3.1001.8c-Isolatehigh-temperatureelements
3.1001.8c-Isolatehigh-temperatureelements
DesiredOutcome:Combustiblematerialskeptawayfromcombustionsources
Specification(s):Arigid,fixeddamhavingaheightgreaterthantheinsulationtobeinstalledwillbeconstructedtoensurea3"clearancebetweencombustionflueventanddam
Objective(s):Ensuredammaterialdoesnotbend,move,orsag
Preventafirehazard
AirSealing>Attics>PenetrationsandChases3.1001.8d-Sealantselection
3.1001.8d-SealantselectionDesiredOutcome:Combustiblematerialskeptawayfromcombustionsources
Specification(s):Sealantswillbecompatiblewiththeirintendedsurfacesandappliedinaccordancewithmanufacturerspecifications
Selectionwillbedurable,pestresistant,andhaveaweather-appropriateseal
Indoorsealantswillbelowvolatileorganiccompound(VOC)
Fire-resistance-ratedassemblieswillbeprovidedwithsealantspermittedbytheauthorityhavingjurisdictionandadoptedbuildingcode
Objective(s):Preventintrusionofmoistureandpestsintothesealedassembly
PreventexposingworkersoroccupantstoexcessiveVOClevels
Ensuresealantmeetsorexceedstheperformancecharacteristicsoftheassemblyandiscompliantwithlocalfirecoderequirements
AirSealing>Attics>PenetrationsandChases3.1001.8e-Safety
3.1001.8e-SafetyDesiredOutcome:Combustiblematerialskeptawayfromcombustionsources
Specification(s):Insulationwillnotbeallowedbetweenaheat-generatingapplianceandadamunlessmaterialisratedforcontactwithheat-generatingsources
Objective(s):Preventafirehazard
AirSealing>Attics>PenetrationsandChases3.1001.8f-Buildingoperationsstaffeducation
3.1001.8f-BuildingoperationsstaffeducationDesiredOutcome:Combustiblematerialskeptawayfromcombustionsources
Specification(s):DocumentationofmaterialandR-valuewillbeprovidedtobuildingoperationsstaff
Objective(s):Provideoccupantwithdocumentationofinstallation
AirSealing>Attics>PenetrationsandChases
3.1001.9-SealingAccessDoorsandSimilarIntentionalPenetrationsDesiredOutcome:Atticaccessdoorproperlysealedandinsulated
AirSealing>Attics>PenetrationsandChases3.1001.9a-Workersafety
3.1001.9a-WorkersafetyDesiredOutcome:Atticaccessdoorproperlysealedandinsulated
Specification(s):AllworkersafetyspecificationswillbeinaccordancewithSWS2.0100.3WorkerSafety
Objective(s):Ensureworkersafety,especiallyinregardtofallprotectionconsiderationsandcontaminantsfoundindemolition,suchasasbestos,lead,polychlorinatedbiphenyls,etc.
AirSealing>Attics>PenetrationsandChases3.1001.9b-Occupantsafety
3.1001.9b-OccupantsafetyDesiredOutcome:Atticaccessdoorproperlysealedandinsulated
Specification(s):Occupantwillbenotifiedofchangesorrepairstobemade
Anoccupantsafetyplanwillbepreparedandimplemented
Objective(s):Ensureoccupantsafety
AirSealing>Attics>PenetrationsandChases3.1001.9c-Pre-inspection
3.1001.9c-Pre-inspectionDesiredOutcome:Atticaccessdoorproperlysealedandinsulated
Specification(s):Ifatticaccessisbelowtheairandthermalboundary,thentheroofandanyexteriorroofaccesslocationswillbeaddressedinaccordancewithSWS3.1801.2SealingandInsulatingExteriorRoofAccessPanelsandHatches
Ifatticaccessispartoftheairandthermalboundary,itwillbeairtightandinsulated
Objective(s):Ensurecorrectplanofworkisselectedtomaintaintheairandthermalboundary
AirSealing>Attics>PenetrationsandChases3.1001.9d-Sealantselection
3.1001.9d-SealantselectionDesiredOutcome:Atticaccessdoorproperlysealedandinsulated
Specification(s):Sealantswillbecompatiblewiththeirintendedsurfacesandappliedinaccordancewithmanufacturerspecifications
Selectionwillbedurable,pestresistant,andhaveaweather-appropriateseal
Indoorsealantswillbelowvolatileorganiccompound(VOC)productsthatmeetindependenttestingandverificationprotocols,suchasGreenSealGS-36,"GREENGUARDChildrenandSchools,"orcomparablecertifications
Fire-resistance-ratedassemblieswillbeprovidedwithsealantspermittedbytheauthorityhavingjurisdictionandadoptedbuildingcode
Objective(s):Preventintrusionofmoistureandpestsintothesealedassembly
PreventexposingworkersoroccupantstoexcessiveVOClevels
Ensuresealantmeetsorexceedstheperformancecharacteristicsoftheassemblyandiscompliantwithlocalfirecoderequirements
AirSealing>Attics>PenetrationsandChases3.1001.9e-Sealing
3.1001.9e-SealingDesiredOutcome:Atticaccessdoorproperlysealedandinsulated
Specification(s):Accesshatchframeswillbesealedusingcaulk,gasket,weatherstrip,orotherwisesealedwithanairbarriermaterial,suitablefilm,orsolidmaterial
Optionswillbeinstalledwithalatch,lock,orfrictionallyengagedcomponentsofaprefabricatedunitabovetheopeningthatdonotrequirealatch
Arigiddamhavingaheightgreaterthantheinsulationtobeinstalledwillbeconstructedtocontaininsulationwhenatticaccessisopened
Objective(s):Preventairleakage
NewMexicoWAPvariancestates:Ifstructurecauseslimitation,aninsulationbaffle/damwillbeinstalledusingfiberglassbattsthatishigherthantheinsulationtobeinstalled,orashighastheoverheadspacewillallow.
AirSealing>Attics>PenetrationsandChases3.1001.9f-Installation
3.1001.9f-InstallationDesiredOutcome:Atticaccessdoorproperlysealedandinsulated
Specification(s):AccesshatcheswillbeinsulatedwithnoncompressibleinsulationtothesameR-valueasadjoininginsulatedassembly
Attichatchroughopeningwillbesurroundedwithadurable,rigidprotectivebafflethatishigherthanthelevelofthesurroundingatticfloorinsulation
Objective(s):AchieveuniformR-valueontheatticdoororhatch
AchieveuniformR-valueontheatticfloor
Preventlooseatticfloorinsulationfromenteringthelivingarea
AirSealing>Attics>PenetrationsandChases3.1001.9g-Attachment
3.1001.9g-AttachmentDesiredOutcome:Atticaccessdoorproperlysealedandinsulated
Specification(s):Insulationwillbepermanentlyattachedandincompletecontactwiththeairbarrier
Objective(s):InsulatetoprescribedR-value
AirSealing>Attics>PenetrationsandChases3.1001.9h-Qualityassurance
3.1001.9h-QualityassuranceDesiredOutcome:Atticaccessdoorproperlysealedandinsulated
Specification(s):Atticaccesswillbeadjustedtoproperlyfitthejambandallowforeaseofoperationandsecurity
AtticaccesssystemwillbetestedforairleakageinaccordancewithASTME1186
Objective(s):Ensureproperoperationoftheatticaccessandhardware
Preventairleakagethroughassembly
AirSealing>Attics>PenetrationsandChases3.1001.9i-Durability
3.1001.9i-DurabilityDesiredOutcome:Atticaccessdoorproperlysealedandinsulated
Specification(s):Completedmeasurewillhaveaminimumexpectedservicelifeof20years
Objective(s):Ensureaminimumexpectedservicelife
AirSealing>Attics>PenetrationsandChases3.1001.9j-Buildingoperationsstaff/occupanteducation
3.1001.9j-Buildingoperationsstaff/occupanteducationDesiredOutcome:Atticaccessdoorproperlysealedandinsulated
Specification(s):Purposeofinsulationandproperhatchoperationwillbecommunicatedtobuildingoperationsstaffandoccupant
Objective(s):Occupantandstaffunderstandhowtousethehatchtoensureintegrityofinsulatedandsealedassemblythroughoutservicelife
AirSealing>Attics>OtherCeilingMaterials
3.1005.3-AirSealingComplexCeilingPlanesDesiredOutcome:Configurationofcomplexceilingplaneswillbesimplifiedbyspanninginteriorsoffits,chases,directpenetrations,andothercavitiestoprovideacontinuouslysealedairbarrierbetweenunconditionedatticandconditionedspace
AirSealing>Attics>OtherCeilingMaterials3.1005.3a-Pre-inspection
3.1005.3a-Pre-inspectionDesiredOutcome:Configurationofcomplexceilingplaneswillbesimplifiedbyspanninginteriorsoffits,chases,directpenetrations,andothercavitiestoprovideacontinuouslysealedairbarrierbetweenunconditionedatticandconditionedspace
Specification(s):Conductpre-inspectioninaccordancewithSWS2.0100.4WorkAreaInspectionandStabilization
Gaps,cracks,andholesinfireseparationslocatedwithintheworkareawillbevisuallyidentifiedandincorporatedintoairsealingworkscope,includingthosethatspantwoconditionedorunconditionedspaces
Wheredrawingsareavailablethatidentifyspecificfire-resistanceratings(i.e.,1hour,2hour),materialsandmethodswillbeemployedtopreserveorrestoresuchrating
Wheredrawingsareunavailableordonotidentifyspecificfire-resistanceratings,thefire-resistanceratingoftheassemblymaybeinferredfromthecurrentconstruction(i.e.,single5/8sheetrock,concretemasonryunit),andmaterialsandmethodsemployedwillbeconsistentwithrestoringorpreservingsuchinferredfire-resistancerating
Repairsnecessarytostabilizeworkareasandprotectorpreserveintegrityofenergyimprovementwillbecompletedbeforesubjectworkbegins
Objective(s):Ensuredurabilityofrepairs
AirSealing>Attics>OtherCeilingMaterials3.1005.3b-Locateairsealingplane
3.1005.3b-LocateairsealingplaneDesiredOutcome:Configurationofcomplexceilingplaneswillbesimplifiedbyspanninginteriorsoffits,chases,directpenetrations,andothercavitiestoprovideacontinuouslysealedairbarrierbetweenunconditionedatticandconditionedspace
Specification(s):Workareawillbeclearedofexistinginsulationtolocateandidentifytheoptimalairsealingplane
Elevationchanges,includinginteriorsoffits,chases,directpenetrations,andotherchangesinelevation,willbeidentifiedtodeterminewhichwillbeplacedontheconditionedsideoftheairbarrierandwhichwillbesealedatallsurfaces
Wherepractical,thetotalsquarefootageoftheairbarrierwillbeminimizedbycappingorsealingopeningsintheprimeair-barrierplane,ratherthanonallsidesoftheelevationchange
Objective(s):Minimizegrossairbarrier(andsubsequentthermalbarrier)squarefootagebysealingoverelevationchangesinunconditionedatticspaces
AirSealing>Attics>OtherCeilingMaterials3.1005.3c-Spanningmaterialselection
3.1005.3c-SpanningmaterialselectionDesiredOutcome:Configurationofcomplexceilingplaneswillbesimplifiedbyspanninginteriorsoffits,chases,directpenetrations,andothercavitiestoprovideacontinuouslysealedairbarrierbetweenunconditionedatticandconditionedspace
Specification(s):Materialsusedtospanelevationchangeswillberigidandself-supportingoverthedistancespanned
Materialswillbeconsistentwithexistingorintendedfire-resistanceassemblies
Materialswillbecompatiblewithadjacentmaterialsandwithanyproposedinsulationdesignedtocomeincontactwithit
Theperimetersofallmaterialsinstalledtospanelevationchangeswillbesealedonallexposededgeswithcompatiblesealants
Sealswillbeusedthatpreventvisibleairmovementusingchemicalsmokeat50pascalsofpressuredifference
Objective(s):Preventairleakagefromcomplexceilingplanes.Provideairtight,durablesealthatdoesnotmove,bend,orsagandcansupporttheweightofinstalledinsulation
NewMexicoWAPvariancestates:Infraredthermographyorotherapprovedmethodmaybeusedinplaceofchemicalsmoketoverifyairsealing.
AirSealing>Attics>OtherCeilingMaterials3.1005.3d-Support
3.1005.3d-SupportDesiredOutcome:Configurationofcomplexceilingplaneswillbesimplifiedbyspanninginteriorsoffits,chases,directpenetrations,andothercavitiestoprovideacontinuouslysealedairbarrierbetweenunconditionedatticandconditionedspace
Specification(s):Supportmaterialwillbeinstalledforspanswiderthan24"exceptwhenair-barriermaterialisratedtospangreaterdistanceunderload(e.g.,wind,insulation)
Objective(s):Ensuresealstaysinplaceanddoesnotsag
AirSealing>Attics>OtherCeilingMaterials3.1005.3e-Jointseal
3.1005.3e-JointsealDesiredOutcome:Configurationofcomplexceilingplaneswillbesimplifiedbyspanninginteriorsoffits,chases,directpenetrations,andothercavitiestoprovideacontinuouslysealedairbarrierbetweenunconditionedatticandconditionedspace
Specification(s):Continuoussealwillbeinstalledaroundseams,cracks,joints,edges,penetrations,andconnections
Prefabricatedunitsmaybeusedwhenmeetingthedesiredoutcome
Objective(s):Provideairtight,durablesealthatdoesnotmove,bend,orsag
AirSealing>Attics>OtherCeilingMaterials3.1005.3f-Sealantselection
3.1005.3f-SealantselectionDesiredOutcome:Configurationofcomplexceilingplaneswillbesimplifiedbyspanninginteriorsoffits,chases,directpenetrations,andothercavitiestoprovideacontinuouslysealedairbarrierbetweenunconditionedatticandconditionedspace
Specification(s):Sealantswillbecompatiblewiththeirintendedsurfacesandappliedinaccordancewithmanufacturerspecifications
Selectionwillbedurable,pestresistant,andhaveaweather-appropriateseal
Indoorsealantswillbelowvolatileorganiccompounds(VOC)productsthatmeetindependenttestingandverificationprotocols,suchasGreenSealGS-36,"GREENGUARDChildrenandSchools,"orcomparablecertifications
Fire-resistance-ratedassemblieswillbeprovidedwithsealantspermittedbytheauthorityhavingjurisdictionandadoptedbuildingcode
Objective(s):Preventintrusionofmoistureandpestsintothesealedassembly
PreventexposingworkersoroccupantstoexcessiveVOClevels
Ensuresealantmeetsorexceedstheperformancecharacteristicsoftheassemblyandiscompliantwithlocalfirecoderequirements
AirSealing>Walls>MultifamilyWalls
3.1102.1-WallPenetrationSealingDesiredOutcome:Wallpenetrationssealedtopreventairleakage,moisturemovement,pestmigration,soundand/orodortransmission,andspreadoffirethroughthewall
Note:
AirSealing>Walls>MultifamilyWalls3.1102.1a-Pre-inspection
3.1102.1a-Pre-inspectionDesiredOutcome:Wallpenetrationssealedtopreventairleakage,moisturemovement,pestmigration,soundand/orodortransmission,andspreadoffirethroughthewall
Specification(s):Conductpre-inspectioninaccordancewithSWS2.0100.4WorkAreaInspectionandStabilization
Gaps,cracks,andholesinfireseparationslocatedwithintheworkareawillbevisuallyidentifiedandincorporatedintoairsealingworkscope,includingthosethatspantwoconditionedorunconditionedspaces
Wheredrawingsareavailablethatidentifyspecificfire-resistanceratings(i.e.,1hour,2hour),materialsandmethodswillbeemployedtopreserveorrestoresuchrating
Wheredrawingsareunavailableordonotidentifyspecificfire-resistanceratings,thefire-resistanceratingoftheassemblymaybeinferredfromthecurrentconstruction(i.e.,single5/8sheetrock,concretemasonryunit(CMU),andmaterialsandmethodsemployedwillbeconsistentwithrestoringorpreservingsuchinferredfireresistancerating
Penetrationlocationswillbeidentifiedtodetermineholesizeandfirerating
Objective(s):Ensureadurable,continuousairbarrierandafire-ratedassembly,whereappropriate
AirSealing>Walls>MultifamilyWalls3.1102.1b-Backingandinfill
3.1102.1b-BackingandinfillDesiredOutcome:Wallpenetrationssealedtopreventairleakage,moisturemovement,pestmigration,soundand/orodortransmission,andspreadoffirethroughthewall
Specification(s):Wheregaps,cracks,orholesarelargerthan1/4"acrossand/orwheretheairsealingmaterialswillbesubjecttotemperaturevariationsinexcessof50°F,theneedforbackingorinfillwillbeevaluated
Ifused,backingorinfillwillmeetspecificcharacteristicsofthefire-resistance-ratedassemblyandbecompatiblewiththecharacteristicsofthegap,crack,orhole,includingpreservationofanyexpansion/contractioncharacteristicsforassembly(e.g.,expansionjoints,steampipes,ordissimilarmaterialinterfaceswithdifferingcoefficientsofexpansion)
Backingorinfillwillbeselectedthatmaintainssealantplacementanddurabilitywhileallowingfortheexpectedmovementfromexpansion,contraction,loaddeflection,settlingatthelocation,orifexistingwatercontrolmeasuresarecompromised(e.g.,rainscreen,dripedge,weepholes,gutterandroofdrains,scuppers,orotherexteriorwatermanagementelements)
Objective(s):Minimizegaporholesizetoensuresuccessfuluseofsealant
Ensureclosureisdurable,pestresistant,weatherappropriate,andsupportsappropriateload(e.g.,wind,snow,insulation)
Ensuresealantdoesnotfallout
Ensureintegrityoftheexistingwatercontrolsystem
AirSealing>Walls>MultifamilyWalls3.1102.1c-Sealantselection
3.1102.1c-SealantselectionDesiredOutcome:Wallpenetrationssealedtopreventairleakage,moisturemovement,pestmigration,soundand/orodortransmission,andspreadoffirethroughthewall
Specification(s):Sealantswillbecompatiblewiththeirintendedsurfacesandappliedinaccordancewithmanufacturerspecifications
Selectionwillbedurable,pestresistant,andhaveaweather-appropriateseal
Indoorsealantswillbelowvolatileorganiccompound(VOC)productsthatmeetindependenttestingandverificationprotocols,suchasGreenSealGS-36,"GREENGUARDChildrenandSchools,"orcomparablecertifications
Fire-resistance-ratedassemblieswillbeprovidedwithsealantspermittedbytheauthorityhavingjurisdictionandadoptedbuildingcode
Objective(s):Preventintrusionofmoistureandpestsintothesealedassembly
PreventexposingworkersoroccupantstoexcessiveVOClevels
Ensuresealantmeetsorexceedstheperformancecharacteristicsoftheassemblyandiscompliantwithlocalfirecoderequirements
AirSealing>Walls>MultifamilyWalls3.1102.1d-High-temperatureapplication
3.1102.1d-High-temperatureapplicationDesiredOutcome:Wallpenetrationssealedtopreventairleakage,moisturemovement,pestmigration,soundand/orodortransmission,andspreadoffirethroughthewall
Specification(s):Onlynoncombustiblesealantwillbeusedincontactwithchimneys,ventsandflues,oranyheatsource(e.g.non-IC-ratedrecessedlights,heatlamps,etc.)
Objective(s):Provideairtight,durablesealthatdoesnotmove,bend,sag,orcombust
Preventafirehazard
AirSealing>Walls>MultifamilyWalls3.1102.1e-Penetrationseal
3.1102.1e-PenetrationsealDesiredOutcome:Wallpenetrationssealedtopreventairleakage,moisturemovement,pestmigration,soundand/orodortransmission,andspreadoffirethroughthewall
Specification(s):Continuoussealwillbeinstalledaroundseams,cracks,joints,edges,andpenetrations
Whenapenetrationgoesallthewaythroughawall,bothsideswillbesealed
InahollowcoreCMUwall,thepenetrationattheinnerwallsurfaceandtheexteriorwallsurfacewillbesealed,butnotcompromiseexistingwatercontrolmeasures(e.g.,rainscreen,dripedge,weepholes,gutter,androofdrains)
Objective(s):Provideairtight,durablesealthatdoesnotmove,bend,orsag
Maintainintegrityoftheexistingwatercontrolsystem
AirSealing>WindowsandDoors>Maintenance,Repair,andSealing
3.1201.7-Repair,Maintenance,andWeatherStrippingofWindowsDesiredOutcome:Windowsareairtightandweathertight
Note:
AirSealing>WindowsandDoors>Maintenance,Repair,andSealing3.1201.7a-Workersafety
3.1201.7a-WorkersafetyDesiredOutcome:Windowsareairtightandweathertight
Specification(s):AllworkersafetyspecificationswillbeinaccordancewithSWS2.0100.3WorkerSafety
Objective(s):Ensureworkersafety,especiallyinregardtofallprotectionconsiderationsandcontaminantsfoundindemolition,suchasasbestos,lead,polychlorinatedbiphenyls,etc.
AirSealing>WindowsandDoors>Maintenance,Repair,andSealing3.1201.7b-Occupantsafety
3.1201.7b-OccupantsafetyDesiredOutcome:Windowsareairtightandweathertight
Specification(s):Occupantwillbenotifiedofchangesorrepairstobemade
Anoccupantsafetyplanwillbepreparedandimplemented
Occupantwillbeshownhowtoproperlyoperatethewindowsystem
Objective(s):Ensureoccupantsafety
AirSealing>WindowsandDoors>Maintenance,Repair,andSealing3.1201.7c-Pre-inspection
3.1201.7c-Pre-inspectionDesiredOutcome:Windowsareairtightandweathertight
Specification(s):Glazingsystemswillbeinspectedforairandwaterleakage,warping,stability,holes,properhardwareoperation,properoperation,andsecurity;iftheitemsabovecannotberepaired,theglazingsystemswillberecommendedforreplacement
Objective(s):Determinethescopeofglazingsystemrepair
AirSealing>WindowsandDoors>Maintenance,Repair,andSealing3.1201.7d-Operableglazingsystemoperationandfit
3.1201.7d-OperableglazingsystemoperationandfitDesiredOutcome:Windowsareairtightandweathertight
Specification(s):Operableglazingsystemwillbeadjustedorrepairedtoproperlyfitthejambandallowforeaseofoperation(e.g.,hardwareadjustmentand/orreplacement)
Objective(s):Ensureproperoperationoftheoperableglazingsystem
AirSealing>WindowsandDoors>Maintenance,Repair,andSealing3.1201.7e-Fixedglazingsystemadjustmentandseal
3.1201.7e-FixedglazingsystemadjustmentandsealDesiredOutcome:Windowsareairtightandweathertight
Specification(s):Fixedglazingsystemwillbeadjustedorrepairedtoproperlyfitthejamb
Intheeventthefixedglazingunithasshiftedenoughtoallowlighttoleakaroundtheperimeterframe,theglasswillbeproperlyrepositionedinitsframe/pocket
Afterrepositioning/adjusting,theglasswillbesealedtotheframe
Whensealingexteriorframecomponents,internalwaterdrainagesystemswithintheglazingsystemwillbemaintained
Whensealingexteriorframecomponents,wallsystemwatermanagementcomponentswillbemaintained(e.g.,weepholes)
Objective(s):Ensureproperadjustmentofglass(e.g.,caulkingusedtosealagapcancompromisetheintegrityofthethermalpaneseal)
Ensureanairtightandweathertightfixedglazingsystem
Ensureadurableandsecureglazingsystem
Preventwaterintrusion
AirSealing>WindowsandDoors>Maintenance,Repair,andSealing3.1201.7f-Sealantselection
3.1201.7f-SealantselectionDesiredOutcome:Windowsareairtightandweathertight
Specification(s):
Sealantswillbecompatiblewiththeirintendedsurfacesandappliedinaccordancewithmanufacturerspecifications
Selectionwillbedurable,pestresistant,andhaveaweather-appropriateseal
Indoorsealantswillbelowvolatileorganiccompound(VOC)productsthatmeetindependenttestingandverificationprotocols,suchasGreenSealGS-36,"GREENGUARDChildrenandSchools,"orcomparablecertifications
Fireresistanceratedassemblieswillbeprovidedwithsealantspermittedbytheauthorityhavingjurisdictionandadoptedbuildingcode
Objective(s):Preventintrusionofmoistureandpestsintothesealedassembly
PreventexposingworkersoroccupantstoexcessiveVOClevels
Ensuresealantmeetsorexceedstheperformancecharacteristicsoftheassemblyandiscompliantwithlocalfirecoderequirements
AirSealing>WindowsandDoors>Maintenance,Repair,andSealing3.1201.7g-Framesealing
3.1201.7g-FramesealingDesiredOutcome:Windowsareairtightandweathertight
Specification(s):Whentheglazingsystemtrim/frameleaksatwall,theglazingsystemtrim/framewillbesealedtotheexteriorand/orinteriorsideofthewall
Whentheglazingsystemcomponentsleakattheframe,areasofleakagewillbesealed
Whentheexistingwindowframehaspenetrationsduetooldhardware,theabandonedpenetrationswillbesealed
Whensealingexteriorframecomponents,internalwaterdrainagesystemswithintheglazingsystemwillbemaintained
Whensealingexteriorframecomponents,wallsystemwatermanagementcomponentswillbemaintained(e.g.,weepholes)
Objective(s):Ensuretheglazingsystemframeisairtightandwatertight
Preventwaterintrusion
AirSealing>WindowsandDoors>Maintenance,Repair,andSealing3.1201.7h-Weatherstripping
3.1201.7h-WeatherstrippingDesiredOutcome:Windowsareairtightandweathertight
Specification(s):Allweatherstrippingwillbeaneffectiveairbarrier
Durableweatherstrippingmaterialwillbesizedtospanirregularitiesintheglazingsystem,aswellasseasonalvariations
Whereweatherstrippingfitsintoanexistingtrack,replacementweatherstripwillbesizedtofittheoriginaltrackandtospanirregularities
Weatherstrippingwillbeinstalledandmechanicallyfastenedaroundallfoursidesoftheglazingsystem
Mechanicallyinstalledweatherstrippingcarrierwillbesealedtosurface
Operableglazingsystemswillbetestedforeaseofoperationandairtightnessafterweatherstrippingisinstalled
Objective(s):Identifyappropriateweatherstrippingmaterialstomakeanairtightandwatertightsealwhilemaintainingtheoperationoftheglazingsystem
Ensureglazingsystemisairtightandallowsforseasonalvariation
Ensureoperableglazingsystemoperatesproperlyafterweatherstrippingisinstalled
AirSealing>WindowsandDoors>Maintenance,Repair,andSealing3.1201.7i-Qualityassurance
3.1201.7i-QualityassuranceDesiredOutcome:Windowsareairtightandweathertight
Specification(s):Glazingsystemwillbeadjustedtoproperlyfitthejambandallowforeaseofoperationandsecurity
GlazingsystemwillbetestedforairleakageinaccordancewithASTME783-02orASTME1186
Watermanagementsystemsandenclosuredrainageplaneswillbeverifiedasmaintained
Objective(s):Ensureproperoperationoftheglazingsystemandhardware
Preventairleakagethroughassembly
Preventwaterintrusion
AirSealing>WindowsandDoors>Maintenance,Repair,andSealing
3.1201.8-Repair,Maintenance,andWeatherStrippingofDoorsDesiredOutcome:Doorsoperable,airtight,andweathertight
Note:
AirSealing>WindowsandDoors>Maintenance,Repair,andSealing3.1201.8a-Workersafety
3.1201.8a-WorkersafetyDesiredOutcome:Doorsoperable,airtight,andweathertight
Specification(s):AllworkersafetyspecificationswillbeinaccordancewithSWS2.0100.3WorkerSafety
Objective(s):Ensureworkersafety,especiallyinregardtofallprotectionconsiderationsandcontaminantsfoundindemolition,suchasasbestos,lead,polychlorinatedbiphenyls,etc.
AirSealing>WindowsandDoors>Maintenance,Repair,andSealing3.1201.8b-Occupantsafety
3.1201.8b-OccupantsafetyDesiredOutcome:Doorsoperable,airtight,andweathertight
Specification(s):Occupantwillbenotifiedofchangesorrepairstobemade
Anoccupantsafetyplanwillbepreparedandimplemented
Occupantwillbenotifiedofhowtoproperlyoperatethedoorsystem
Objective(s):Ensureoccupantsafety
AirSealing>WindowsandDoors>Maintenance,Repair,andSealing3.1201.8c-Pre-inspection
3.1201.8c-Pre-inspectionDesiredOutcome:Doorsoperable,airtight,andweathertight
Specification(s):Doorsystemwillbeinspectedforairandwaterleakage,warping,stability,holes,properhardwareoperation,properoperation,andsecurity;iftheitemscannotberepaired,thedoorwillberecommendedforreplacement
Objective(s):Determinethescopeofdoorsystemrepair
AirSealing>WindowsandDoors>Maintenance,Repair,andSealing3.1201.8d-Dooroperationandfit
3.1201.8d-DooroperationandfitDesiredOutcome:Doorsoperable,airtight,andweathertight
Specification(s):Doorwillbeadjustedorrepairedtoproperlyfitthejambandallowforeaseofoperation(e.g.,hardwareadjustmentand/orreplacement,re-planedoor)
Objective(s):Ensureproperoperationofthedoorsystem
AirSealing>WindowsandDoors>Maintenance,Repair,andSealing3.1201.8e-Sealantselection
3.1201.8e-SealantselectionDesiredOutcome:Doorsoperable,airtight,andweathertight
Specification(s):Sealantswillbecompatiblewiththeirintendedsurfacesandappliedinaccordancewithmanufacturerspecifications
Selectionwillbedurable,pestresistant,andhaveaweather-appropriateseal
Indoorsealantswillbelowvolatileorganiccompound(VOC)productsthatmeetindependenttestingandverificationprotocols,suchasGreenSealGS-36,"GREENGUARDChildrenandSchools,"orcomparablecertifications
Fire-resistance-ratedassemblieswillbeprovidedwithsealantspermittedbytheauthorityhavingjurisdictionandadoptedbuildingcode
Objective(s):Preventintrusionofmoistureandpestsintothesealedassembly
PreventexposingworkersoroccupantstoexcessiveVOClevels
Ensuresealantmeetsorexceedstheperformancecharacteristicsoftheassemblyandiscompliantwithlocalfirecoderequirements
AirSealing>WindowsandDoors>Maintenance,Repair,andSealing3.1201.8f-Framesealing
3.1201.8f-FramesealingDesiredOutcome:Doorsoperable,airtight,andweathertight
Specification(s):Whenthedoortrim/frameleaksatwall,thedoortrim/framewillbesealedtoboththeexteriorandinteriorsideofthewall
Doorstopwillbesealedtodoorframe
Whentheexistingdoorframehaspenetrationsduetooldhardware,theabandonedpenetrationswillbesealed
Doorrail(bottom)andthresholdwillbeadjustedandsealedtoensuretightbutoperablefit
Objective(s):Ensurethedoortrim/frameisairtightandwatertight
AirSealing>WindowsandDoors>Maintenance,Repair,andSealing3.1201.8g-Weatherstripping
3.1201.8g-WeatherstrippingDesiredOutcome:Doorsoperable,airtight,andweathertight
Specification(s):Allweatherstrippingwillbeaneffectiveairbarrier
Durableweatherstrippingmaterialwillbesizedtospanirregularitiesinthedoor/frame,aswellasseasonalvariations
Forslidersandcommercialdoorsystemswhereweatherstrippingfitsintoanexistingtrack,replacementweatherstripwillbesizedtofittheoriginaltrackandtospanirregularities
Weatherstrippingwillbeinstalledaroundallfoursidesofthedoor
Mechanicallyinstalledweatherstrippingcarrierwillbesealedtosurface
Doorwillbetestedforeaseofoperationandairtightnessafterweatherstrippingisinstalled
Wheredoorsarerequiredtohaveafire-resistancerating,allweatherstripsandsealantsappliedtothedoorwillbecompatiblewiththelistingofthedoor
Objective(s):Identifyappropriateweatherstrippingmaterialstomakeanairtightandwatertightsealwhilemaintainingtheoperationofthedoor
Ensuredoorisairtighttoallowforseasonalvariation
Ensuredooroperatesproperlyafterweatherstrippingisinstalled
AirSealing>WindowsandDoors>Maintenance,Repair,andSealing3.1201.8h-Qualityassurance
3.1201.8h-QualityassuranceDesiredOutcome:Doorsoperable,airtight,andweathertight
Specification(s):Doorwillbeadjustedtoproperlyfitthejamb,andallowforeaseofoperationandsecurity
DoorsystemwillbetestedforairleakageinaccordancewithASTME783-02orASTME1186
Objective(s):Ensureproperoperationofthedoorandhardware
Preventairleakagethroughassembly
AirSealing>WindowsandDoors>Replacement
3.1203.4-WindowReplacementDesiredOutcome:Maintainacontinuousairandthermalbarrier,andhighefficiencywindowperformance
Note:
AirSealing>WindowsandDoors>Replacement3.1203.4a-Designconsiderations
3.1203.4a-DesignconsiderationsDesiredOutcome:Maintainacontinuousairandthermalbarrier,andhighefficiencywindowperformance
Specification(s):Glazingtypewillbechosenbylocationinthebuilding,buildingheight,code,andclimate
Windowframewillbeinsulatedandselectedwiththermalbreaksappropriatetoclimate
Windowselectionwillbebasedonlowestairleakagerating
WindowselectionwillbebasedonNationalFenestrationRatingCouncil(NFRC)ratingbyclimate
GlazingwithlowestfeasibleU-valuewillbespecified
Windowglazingsolarheatgaincoefficient(SHGC)willbeselectedbybuildingorientationandclimate
Watermanagementsystemwillbemaintained
WindowswillmeettheperformancestandardAMAA/WDMA/CSA/101/IS2/A440
Historicpreservationrequirementswillbeconsidered
Objective(s):Ensurethemosteffectiveandappropriateglazingsystemisspecified
AirSealing>WindowsandDoors>Replacement3.1203.4b-Pre-Inspection
3.1203.4b-Pre-InspectionDesiredOutcome:Maintainacontinuousairandthermalbarrier,andhighefficiencywindowperformance
Specification(s):Conductpre-inspectioninaccordancewithSWS2.0100.4WorkAreaInspectionandStabilization
Objective(s):Ensuresafety,effectiveness,anddurabilityofimprovements
AirSealing>WindowsandDoors>Replacement3.1203.4c-Workersafety
3.1203.4c-Workersafety
DesiredOutcome:Maintainacontinuousairandthermalbarrier,andhighefficiencywindowperformance
Specification(s):AllworkersafetyspecificationswillbeinaccordancewithSWS2.0100.3WorkerSafety
Objective(s):Ensureworkersafety,especiallyinregardtofallprotectionconsiderationsandcontaminantsfoundindemolition,suchasasbestos,lead,polychlorinatedbiphenyls,etc.
AirSealing>WindowsandDoors>Replacement3.1203.4d-Occupantsafety
3.1203.4d-OccupantsafetyDesiredOutcome:Maintainacontinuousairandthermalbarrier,andhighefficiencywindowperformance
Specification(s):Occupantwillbenotifiedofchangesorrepairstobemade
Anoccupantsafetyplanwillbepreparedandimplemented
Occupantwillbeshownhowtoproperlyoperatewindowsanddoors
Buildingmanagementandoccupantswillbenotifiedabouttheriskofachildfallingfromoperablewindowswithsillslocatedmorethan72"aboveanysurfaceoutsidewindowopening
Objective(s):Ensureoccupantsafety
AirSealing>WindowsandDoors>Replacement3.1203.4e-Sealantselection
3.1203.4e-SealantselectionDesiredOutcome:Maintainacontinuousairandthermalbarrier,andhighefficiencywindowperformance
Specification(s):Sealantswillbecompatiblewiththeirintendedsurfacesandappliedinaccordancewithmanufacturerspecifications
Selectionwillbedurable,pestresistant,andhaveaweather-appropriateseal
Indoorsealantswillbelowvolatileorganiccompound(VOC)productsthatmeetindependenttestingandverificationprotocols,suchasGreenSealGS-36,"GREENGUARDChildrenandSchools,"orcomparablecertifications
Fire-resistance-ratedassemblieswillbeprovidedwithsealantspermittedbytheauthorityhavingjurisdictionandadoptedbuildingcode
Objective(s):Preventintrusionofmoistureandpestsintothesealedassembly
PreventexposingworkersoroccupantstoexcessiveVOClevels
Ensuresealantmeetsorexceedstheperformancecharacteristicsoftheassemblyandiscompliantwithlocalfirecoderequirements
AirSealing>WindowsandDoors>Replacement3.1203.4f-Windowlocation,installation,andsealing
3.1203.4f-Windowlocation,installation,andsealingDesiredOutcome:Maintainacontinuousairandthermalbarrier,andhighefficiencywindowperformance
Specification(s):Glazingsystemframewillbealignedwiththewallsystem'sairandthermalboundarytocreateacontinuousairandthermalboundary
Glazingsystemwillbeinstalledinaccordancewithmanufacturerspecifications
Roughopeningwillbepreparedandsealedtothewallsystem'scontinuousairandthermalboundarywithnonexpandingsealants
Whenreplacementwindowsarebeinginstalledwithinanexistingwindowframewheretheoriginalsashhasbeenremoved,thewindowframewillbepreparedandsealedtothewallsystem'scontinuousairandthermalbarrier
Whentheexistingwindowframehasinternalweightpockets,thehardwarewillberemovedandthepocketwillbeinsulatedandsealed
Glazingsystemwillbesealedtotheairtightroughopeningortheairtightexistingframe
Objective(s):Maintainacontinuousairandthermalboundarythroughouttheentirewallsystem
AirSealing>WindowsandDoors>Replacement3.1203.4g-Qualityassurance
3.1203.4g-QualityassuranceDesiredOutcome:Maintainacontinuousairandthermalbarrier,andhighefficiencywindowperformance
Specification(s):AsamplingprotocolwillbeusedtotestglazingsystemforairleakageinaccordancewithASTME783-02
AsamplingprotocolwillbeusedtotestglazingsystemforwaterleakageinaccordancewithASTME1105-00
Objective(s):Ensureairtightandwatertightinstallation
AirSealing>WindowsandDoors>Replacement
3.1203.5-ExteriorDoorReplacementDesiredOutcome:Exteriordoorselectionandinstallationprovidesahighefficiencycontinuousairandthermalboundary
Note:
AirSealing>WindowsandDoors>Replacement3.1203.5a-Designconsiderations
3.1203.5a-DesignconsiderationsDesiredOutcome:Exteriordoorselectionandinstallationprovidesahighefficiencycontinuousairandthermalboundary
Specification(s):Door/glasswillbeselectedbylocationinthebuilding,buildingheight,code,andclimate
Doorframewillbeinsulatedandselectedwiththermalbreaksappropriatetoclimate
Doorselectionwillbebasedonlowestairleakagerating
DoorselectionwillbebasedonNationalFenestrationRatingCouncil(NFRC)ratingbyclimate
DooranddoorglazingwithlowestfeasibleU-valuewillbespecified
GlazingwithindoorassemblieswillcomplywithCPSC16CFRPart1201
Doorglazingsolarheatgaincoefficient(SHGC)willbeselectedbybuildingorientationandclimate
Watermanagementsystemwillbemaintained
Historicpreservationrequirementswillbeconsidered
Objective(s):Ensurethemosteffectiveandappropriatedoorsystemisspecified
AirSealing>WindowsandDoors>Replacement3.1203.5b-Workersafety
3.1203.5b-WorkersafetyDesiredOutcome:Exteriordoorselectionandinstallationprovidesahighefficiencycontinuousairandthermalboundary
Specification(s):AllworkersafetyspecificationswillbeinaccordancewithSWS2.0100.3WorkerSafety
Objective(s):Ensureworkersafety,especiallyinregardtofallprotectionconsiderationsandcontaminantsfoundindemolition,suchasasbestos,lead,polychlorinatedbiphenyls,etc.
AirSealing>WindowsandDoors>Replacement3.1203.5c-Occupantsafety
3.1203.5c-Occupantsafety
DesiredOutcome:Exteriordoorselectionandinstallationprovidesahighefficiencycontinuousairandthermalboundary
Specification(s):Occupantwillbenotifiedofchangesorrepairstobemade
Anoccupantsafetyplanwillbepreparedandimplemented
Occupantwillbeshownhowtoproperlyoperatethedoorsystem
Objective(s):Ensureoccupantsafety
AirSealing>WindowsandDoors>Replacement3.1203.5d-Sealantselection
3.1203.5d-SealantselectionDesiredOutcome:Exteriordoorselectionandinstallationprovidesahighefficiencycontinuousairandthermalboundary
Specification(s):Sealantswillbecompatiblewiththeirintendedsurfacesandappliedinaccordancewithmanufacturerspecifications
Selectionwillbedurable,pestresistant,andhaveaweather-appropriateseal
Indoorsealantswillbelowvolatileorganiccompound(VOC)productsthatmeetindependenttestingandverificationprotocols,suchasGreenSealGS-36,"GREENGUARDChildrenandSchools,"orcomparablecertifications
Fire-resistance-ratedassemblieswillbeprovidedwithsealantspermittedbytheauthorityhavingjurisdictionandadoptedbuildingcode
Objective(s):Preventintrusionofmoistureandpestsintothesealedassembly
PreventexposingworkersoroccupantstoexcessiveVOClevels
Ensuresealantmeetsorexceedstheperformancecharacteristicsoftheassemblyandiscompliantwithlocalfirecoderequirements
AirSealing>WindowsandDoors>Replacement3.1203.5e-Doorlocation,installationandsealing
3.1203.5e-Doorlocation,installationandsealingDesiredOutcome:Exteriordoorselectionandinstallationprovidesahighefficiencycontinuousairandthermalboundary
Specification(s):Doorframewillbealignedwiththewallsystem'sairandthermalboundarytocreateacontinuousairandthermalboundary
Doorsystemwillbeinstalledinaccordancewithmanufacturerspecifications
Roughopeningwillbepreparedandsealedtothewallsystem'scontinuousairandthermalboundary
Doorframewillbesealedandflashedtotheairtightandwatertightroughopening
Whenareplacementdoorisbeinginstalledwithinanexistingframe,theoriginalframewillbepreparedandsealed
tothewallsystem'scontinuousairandthermalboundary,andthedoorwillbeweatherstrippedonallfoursides
Whentheexistingdoorframehaspenetrationsduetooldhardware,theabandonedpenetrationswillbesealed
Doorrail(bottom)andthresholdwillbeadjustedtoensuretightbutoperablefit
Objective(s):Maintainacontinuousairandthermalboundarythroughouttheentirewallsystem
AirSealing>WindowsandDoors>Replacement3.1203.5f-Qualityassurance
3.1203.5f-QualityassuranceDesiredOutcome:Exteriordoorselectionandinstallationprovidesahighefficiencycontinuousairandthermalboundary
Specification(s):Doorwillbeadjustedtoproperlyfitthejambandallowforeaseofoperationandsecurity
AsamplingprotocolwillbeusedtotestdoorsystemforairleakageinaccordancewithASTME783-02orASTME1186
AsamplingprotocolwillbeusedtotestdoorsystemforwaterleakageinaccordancewithASTME1105-00
Objective(s):Ensureproperoperationofthedoorandhardware
Ensureairtightandwatertightinstallation
AirSealing>BasementsandCrawlSpaces>SlabFoundations
3.1403.1-AirSealConcreteFloorSlabFoundation:Raised,OnGrade,andBelow-GradeDesiredOutcome:Effectiveairbarrierbetweentheconditionedspaceandtheground
Note:
AirSealing>BasementsandCrawlSpaces>SlabFoundations3.1403.1a-Pre-inspection
3.1403.1a-Pre-inspectionDesiredOutcome:Effectiveairbarrierbetweentheconditionedspaceandtheground
Specification(s):Conductpre-inspectioninaccordancewithSWS2.0100.4WorkAreaInspectionandStabilization
Whereapplicable(generallyabove-gradeconcreteslabsbetweenconditionedandunconditionedspaces),gaps,cracks,andholesinfireseparationslocatedwithintheworkareawillbevisuallyidentifiedandincorporatedintoairsealingworkscope,includingthosethatspantwoconditionedorunconditionedspaces
Wheredrawingsareavailablethatidentifyspecificfire-resistanceratings(i.e.,1hour,2hour),materialsandmethodswillbeemployedtopreserveorrestoresuchrating
Wheredrawingsareunavailableordonotidentifyspecificfire-resistanceratings,thefire-resistanceratingoftheassemblymaybeinferredfromthecurrentconstruction(i.e.,single5/8sheetrock,concretemasonryunit),andmaterialsandmethodsemployedwillbeconsistentwithrestoringorpreservingsuchinferredfire-resistancerating
Whereapplicable,forassemblytypeandgeographiclocation,testforradonperANSI-AARSTStandard:ProtocolforConductingRadonandRadonDecayProductMeasurementsinMultifamilyBuildings
Repairsnecessarytostabilizeworkareasandprotectorpreserveintegrityofenergyimprovementwillbecompletedbeforesubjectworkbegins
Objective(s):Identifyandcorrectconditionswhichcontributetoexcessiveradonlevels
Provideastableslabtoensuredurabilityofthework
AirSealing>BasementsandCrawlSpaces>SlabFoundations3.1403.1b-Identificationofpenetrations
3.1403.1b-IdentificationofpenetrationsDesiredOutcome:Effectiveairbarrierbetweentheconditionedspaceandtheground
Specification(s):Penetrationswillbeidentifiedusingvisualinspections,smoke,and/orpressuretests[ASTME1186-03(2009)]
Objective(s):Locateairleakagepathwaystorepair
AirSealing>BasementsandCrawlSpaces>SlabFoundations3.1403.1c-Preparation
3.1403.1c-PreparationDesiredOutcome:Effectiveairbarrierbetweentheconditionedspaceandtheground
Specification(s):Healthandsafetyconcernsforoccupantsandworkers,inrelationtorepairsandmaterials,willbeaddressedinaccordancewithOSHAstandards(OSHA1926,1910)
Theareawillbepreparedandisolatedinaccordancewithhealthandsafetystandardsfortheapplicationandmaterials(e.g.,extremetemperatures,lead,asbestos,carbonmonoxide,moisture)
Worklighting,workplatform,andadequateventilationwillbeprovided
Accessnotprovidedwillbecreatedtoensurethatrepairscanbemade(mayincludelocalizeddemolition)
Objective(s):Provideasafeworkenvironment
Providesafeindoorenvironmentalqualityintheworkenvironment
Provideeffectiverepairaccess
AirSealing>BasementsandCrawlSpaces>SlabFoundations3.1403.1d-Sealantandmaterialsselection
3.1403.1d-SealantandmaterialsselectionDesiredOutcome:Effectiveairbarrierbetweentheconditionedspaceandtheground
Specification(s):Sealantsandmaterialswillbecompatiblewiththeirintendedsurfacesandappliedinaccordancewithmanufacturerspecifications
Selectionwillbedurable,pestresistant,andhaveaweather-appropriateseal
Indoorsealantswillbelowvolatileorganiccompound(VOC)productsthatmeetindependenttestingandverificationprotocols,suchasGreenSealGS-36,"GREENGUARDChildrenandSchools,"orcomparablecertifications
Fire-resistance-ratedassemblieswillbeprovidedwithsealantspermittedbytheauthorityhavingjurisdictionandadoptedbuildingcode
Wherepenetrationsareduetofailedormissingexpansionjoints,sealingmaterialswillbesuitableforthisapplication
Objective(s):Preventintrusionofmoistureandpestsintothesealedassembly
PreventexposingworkersoroccupantstoexcessiveVOClevels
Ensuresealantmeetsorexceedstheperformancecharacteristicsoftheassemblyandiscompliantwithlocalfirecoderequirements
AirSealing>BasementsandCrawlSpaces>SlabFoundations3.1403.1e-Demolitionrepair
3.1403.1e-DemolitionrepairDesiredOutcome:Effectiveairbarrierbetweentheconditionedspaceandtheground
Specification(s):Accessholeswillberepaired
Objective(s):Restoresurfacestooriginalconditionorbetter
AirSealing>BasementsandCrawlSpaces>SlabFoundations3.1403.1f-Verification
3.1403.1f-VerificationDesiredOutcome:Effectiveairbarrierbetweentheconditionedspaceandtheground
Specification(s):Repairswillbeverifiedbyvisualinspections,smoke,and/orpressuretestsconsistentwiththepre-inspection
Objective(s):Ensurequalityandeffectivenessofairsealing
AirSealing>Ducts>DuctPreparation
3.1601.6-PreparationandMechanicalFastening—LowRiseDesiredOutcome:Ductsandplenumsareproperlyfastenedtopreventleakage
Note:
AirSealing>Ducts>DuctPreparation3.1601.6a-Preparation
3.1601.6a-PreparationDesiredOutcome:Ductsandplenumsareproperlyfastenedtopreventleakage
Specification(s):Surroundinginsulationwillbeclearedtoexposethejointsbeingsealed
Ductsurfacethatacceptssealantwillbecleaned
Objective(s):Gainaccess
Achieveproperadhesionforairtightseal
AirSealing>Ducts>DuctPreparation3.1601.6b-Metaltometal
3.1601.6b-MetaltometalDesiredOutcome:Ductsandplenumsareproperlyfastenedtopreventleakage
Specification(s):Ductswillbefastenedwithaminimumofthreeequallyspacedscrewsoracceptablemechanicalconnections
Objective(s):Ensurejointsaredurable
AirSealing>Ducts>DuctPreparation3.1601.6c-Flextometal
3.1601.6c-FlextometalDesiredOutcome:Ductsandplenumsareproperlyfastenedtopreventleakage
Specification(s):Jointswillbefastenedwithtiebandsusingatiebandtensioningtoolormechanicalband,andsealedwithapprovedmasticandUL181Btape
Objective(s):Ensurejointsaredurable
Reduceairleakage
AirSealing>Ducts>DuctPreparation3.1601.6d-Ductboardtoductboard
3.1601.6d-DuctboardtoductboardDesiredOutcome:Ductsandplenumsareproperlyfastenedtopreventleakage
Specification(s):Jointswillbefastenedwithaclinchstapler,ratedtape,andmastic
Objective(s):Ensurejointsaredurable
Reduceairleakage
AirSealing>Ducts>DuctPreparation3.1601.6e-Ductboardtoflexibleduct
3.1601.6e-DuctboardtoflexibleductDesiredOutcome:Ductsandplenumsareproperlyfastenedtopreventleakage
Specification(s):Anappropriatetake-offcollarinaccordancewithNAIMAstandardswillbeusedandsealedwithapprovedmastic
Objective(s):Ensurejointsaredurable
Reduceairleakage
AirSealing>Ducts>DuctPreparation3.1601.6f-Metalplenumtoairhandlercabinet
3.1601.6f-MetalplenumtoairhandlercabinetDesiredOutcome:Ductsandplenumsareproperlyfastenedtopreventleakage
Specification(s):Plenumwillbefastenedwithaminimumofthreeequallyspacedscrewsoneachside
Canvasconnectionbetweenplenumandunitwillbeinstalledsothatitdoesnotreducetheinsidedimensionsoftheduct
Objective(s):Ensurejointsaredurable
Reduceairleakage
Optimizeairflow
AirSealing>Ducts>DuctPreparation3.1601.6g-Ductboardplenumtoairhandlercabinet
3.1601.6g-DuctboardplenumtoairhandlercabinetDesiredOutcome:Ductsandplenumsareproperlyfastenedtopreventleakage
Specification(s):Terminationbarormetalstripwillbefastenedwithscrews
Ductboardwillbeinstalledbetweenthescrewandtheterminationbar
Objective(s):Ensurejointsaredurable
Reduceairleakage
AirSealing>Ducts>DuctPreparation3.1601.6h-Terminalboottowood
3.1601.6h-TerminalboottowoodDesiredOutcome:Ductsandplenumsareproperlyfastenedtopreventleakage
Specification(s):Screwsornailswillbeusedtofastenboottowood
Seamsandboottosubfloorwillbesealedwithmastic
Objective(s):Ensurejointsaredurable
Reduceairleakage
AirSealing>Ducts>DuctPreparation3.1601.6i-Terminalboottogypsum
3.1601.6i-TerminalboottogypsumDesiredOutcome:Ductsandplenumsareproperlyfastenedtopreventleakage
Specification(s):Boothangerwillbefastenedtoadjacentframingwithscrewsornails
Bootwillbeconnectedtoboothangerwithscrews
Integralsnapbootswillbeinstalled
Seamsofbootwillbesealedwithmastic
Boottogypsumwillbesealedwithcaulkinaccordancewithlocalcodeandstandards
Objective(s):Ensurejointsaredurable
Reduceairleakage
AirSealing>Ducts>DuctPreparation3.1601.6j-Ductboardtoflex
3.1601.6j-DuctboardtoflexDesiredOutcome:Ductsandplenumsareproperlyfastenedtopreventleakage
Specification(s):Anappropriatetake-offcollarinaccordancewithNAIMAstandardswillbeused
Objective(s):Ensurejointsaredurable
Reduceairleakage
AirSealing>Ducts>DuctPreparation3.1601.6k-Replacementofinsulation
3.1601.6k-ReplacementofinsulationDesiredOutcome:Ductsandplenumsareproperlyfastenedtopreventleakage
Specification(s):InsulationwillbereturnedorreplacedwithequivalentR-value
Objective(s):Maintaininsulationvalue
AirSealing>Ducts>DuctPreparation
3.1601.7-Support—LowRiseDesiredOutcome:Ductsandplenumsareproperlysupported
Note:
AirSealing>Ducts>DuctPreparation3.1601.7a-Supportofducttypes(appliestoallducttypes)
3.1601.7a-Supportofducttypes(appliestoallducttypes)DesiredOutcome:Ductsandplenumsareproperlysupported
Specification(s):Ductworkwillbesupportedinaccordancewiththeapplicablecodeadoptedbythejurisdiction
Flexibleductboardductsandplenumswillbesupportedbymetalstrappingrodsorothermaterialsinaccordancewithapplicablestandards(NAIMA)
Supportmaterialswillbeappliedinawaythatdoesnotallowtheductworktosag,crimptheductwork,orcausetheinteriordimensionsoftheductworktobelessthanspecified
Metalductswillbesupportedbymetalstrapping,rods,orothermaterials,perapplicablestandards
Objective(s):Eliminatefallingandsagging
AirSealing>Ducts>DuctSealing
3.1602.14-Heating,Ventilation,andAirConditioningSupply,andReturnDuctsandPlenumsDesiredOutcome:Connectionsbetweenthecrawlspaceandlivingspaceeliminatedtoimproveindoorairquality(IAQ)andefficiencyofthedistributionsystem
Note:
AirSealing>Ducts>DuctSealing3.1602.14a-Supplyplenums(includesconditionedcrawlspaces)
3.1602.14a-Supplyplenums(includesconditionedcrawlspaces)DesiredOutcome:Connectionsbetweenthecrawlspaceandlivingspaceeliminatedtoimproveindoorairquality(IAQ)andefficiencyofthedistributionsystem
Specification(s):Crawlspacesthatareusedasheatingandcoolingsupplyplenumswillnotbeallowed
Objective(s):ImproveIAQinthelivingspace
Eliminateconnectionbetweenthecrawlspaceandlivingspace
AirSealing>Ducts>DuctSealing3.1602.14b-Returnplenums
3.1602.14b-ReturnplenumsDesiredOutcome:Connectionsbetweenthecrawlspaceandlivingspaceeliminatedtoimproveindoorairquality(IAQ)andefficiencyofthedistributionsystem
Specification(s):Crawlspacesthatareusedasheatingandcoolingreturnplenumswillnotbeallowed
Objective(s):ImproveIAQinthelivingspace
Eliminateconnectionbetweenthecrawlspaceandlivingspace
Improveperformanceefficiency
AirSealing>Ducts>DuctSealing3.1602.14c-Existingconditionwherecrawlspaceisusedassupplyand/orreturnplenum
3.1602.14c-Existingconditionwherecrawlspaceisusedassupplyand/orreturnplenumDesiredOutcome:Connectionsbetweenthecrawlspaceandlivingspaceeliminatedtoimproveindoorairquality(IAQ)andefficiencyofthedistributionsystem
Specification(s):Conditionwillbecorrectedtoprovidesupplyand/orreturnplenumsisolatedfromcrawlspacebeforeworkcancontinue
Objective(s):ImproveIAQinthelivingspace
AirSealing>Ducts>DuctSealing
3.1602.15-VentilationExistingDuctSealing(AllBuildingTypes)DesiredOutcome:Improvedeffectivenessandefficiencyofventilationdistributionsystem
Note:
AirSealing>Ducts>DuctSealing3.1602.15a-Pre-inspection
3.1602.15a-Pre-inspectionDesiredOutcome:Improvedeffectivenessandefficiencyofventilationdistributionsystem
Specification(s):Specificationswillbefieldverifiedasappropriatetositeconditionsbyinstaller(e.g.,firedampers,otherobstructions)
Accesstoallelementsofdistributionsystemwillbeidentified
Accesstoalldwellingunitsandelementsofdistributionsystemwillbeensuredbytheinstaller
Aninspectionwillbeconductedformold,waterleaks,waterdamage,andbreachesinthesurfacesoftheisolatedspacebeforesealing
Repairswillbecompletedbeforesubjectwork
Objective(s):Prepareforinstallation
AirSealing>Ducts>DuctSealing3.1602.15b-Healthandsafety
3.1602.15b-HealthandsafetyDesiredOutcome:Improvedeffectivenessandefficiencyofventilationdistributionsystem
Specification(s):Healthandsafetyconcernsforoccupantsandworkers,inrelationtorepairsandmaterials,willbeaddressedinaccordancewithOSHAstandards(OSHA1926,1910)
Areawillbepreparedandisolatedinaccordancewithhealthandsafetystandardsfortheapplicationandmaterials(e.g.,extremetemperatures,lead,asbestos)
Worklighting,workplatform,andadequateventilationwillbeprovided
Objective(s):Provideasafeworkingenvironment
Providesafeindoorenvironmentalquality(IEQ)intheworkenvironment
Provideeffectiverepairaccess
AirSealing>Ducts>DuctSealing
3.1602.15c-Identificationofleakagelocations
3.1602.15c-IdentificationofleakagelocationsDesiredOutcome:Improvedeffectivenessandefficiencyofventilationdistributionsystem
Specification(s):Ductleakagesiteswillbeidentifiedusingindustryapprovedapproaches(e.g.,visualinspections,borescopes,remotecameras,infraredthermography,smoke,and/orpressuretests[ASTME1186-03{2009}])
Objective(s):Locateairleakagepathwaystorepair
AirSealing>Ducts>DuctSealing3.1602.15d-Identifyandprioritizeleakagelocationstobesealed
3.1602.15d-IdentifyandprioritizeleakagelocationstobesealedDesiredOutcome:Improvedeffectivenessandefficiencyofventilationdistributionsystem
Specification(s):Ductsealingopportunitieswillbeassessedandprioritizedby:
Typeofhole:
1.Catastrophicholesdisconnected,missingducts,orverylargeholes
2.Roofcurb,closetofan,registerboots
3.Holeslargerthan1/4"
4.Seamsandjoints(holeslessthan1/4")
Accessibility:
1.Easytoaccess
2.Demolitionrequired
3.Accessbyinternallyappliedsealants
Objective(s):Maximizeefficiencyofworkeffort
AirSealing>Ducts>DuctSealing3.1602.15e-Temporaryaccess
3.1602.15e-TemporaryaccessDesiredOutcome:Improvedeffectivenessandefficiencyofventilationdistributionsystem
Specification(s):Whendemolitionforaccessisspecified,theinstallerwill:
MakethetemporaryaccessusingappropriatecontainmentandworkerprotectionSealductworkinaccordancewithmanualsealingspecificationslistedinrow3.1602.15hDocumentrepairsusingphotographs,checklist,andtesting,asrequiredRepairtheopeningtospecification
Objective(s):Protectoccupantsandworkersfromwork-relatedcontaminants
Sealductworkinotherwiseinaccessiblelocations
AirSealing>Ducts>DuctSealing3.1602.15f-Preparation
3.1602.15f-PreparationDesiredOutcome:Improvedeffectivenessandefficiencyofventilationdistributionsystem
Specification(s):Ductsandregisterswillbecleanedbeforesealing
Presenceandtypeofdampersandsmokecontroldeviceswillbeidentifiedandprotectedfromduct-sealingapplication
Objective(s):Establishpreconditionsforeffectiveadhesionductsealingmaterials
Ensurehealthandsafetyofoccupant
AirSealing>Ducts>DuctSealing3.1602.15g-Materialselection
3.1602.15g-MaterialselectionDesiredOutcome:Improvedeffectivenessandefficiencyofventilationdistributionsystem
Specification(s):Sealantsandmaterialswillbecompatiblewiththeirintendedsurfacesandappliedinaccordancewithmanufacturerspecifications
DuctsealantswillbeUL181compliant
Sealantsandmaterialswillbecontinuousandmeetfirebarrierspecifications
Objective(s):Ensuresealantsandmaterialsmeetorexceedtheperformancecharacteristicsrequiredoftheassembly(e.g.,firerating)
AirSealing>Ducts>DuctSealing3.1602.15h-Ductsealing
3.1602.15h-DuctsealingDesiredOutcome:Improvedeffectivenessandefficiencyofventilationdistributionsystem
Specification(s):Manualsealingofallaccessibleleakageareaswillbecompletedfirst:
Reconnectdisconnectedducts
RepairmissingductswithlikematerialsForholesgreaterthan1/4",backermaterialwithmasticorappropriatesealantswillbeusedForholessmallerthan1/4",masticorappropriatesealantswillbeused(Somesealedjointswillallowformovement[e.g.,steampipes,deflectionjoints])Ifspecified,internallyappliedsprayoraerosolsealingwillonlybeappliedafteranymanualsealingiscompleteInstallerwillcoordinateaccesstotheventilationductworkintheaffecteddwellingunitswiththebuildingmanagementandspecializedsubcontractor(s)Installerwillprovidelogisticalsupporttosubcontractor(s)(e.g.,remove/replacerooftopfans,maskductterminationsandopenings,manuallysealducts,installfloworifices)Sealantsandsprayswillbeappliedinaccordancewithmanufacturerspecificationsbyaqualifiedcontractor
Thesefinalstepswillbeperformedforallduct-sealingactivities:
VentilationsystemwillbereturnedtooperationalconditionsInstallerwilldocumentsealingwascompletedwithphotographs,checklist,andtesting,asrequiredInstallerwillconductfinalinspectionandconductcloseoutmeetingswithbuildingmanagement
Objective(s):Providepropersequencingofductimprovements
Minimizeinconveniencetooccupants
Preventairleakageinductwork
Preventcontaminationofventilationairflow
Improveeffectivenessandefficiencyofventilationsystem
AirSealing>Ducts>DuctSealing3.1602.15i-Verification
3.1602.15i-VerificationDesiredOutcome:Improvedeffectivenessandefficiencyofventilationdistributionsystem
Specification(s):Finalvisualinspectionofductsealingactivitiesandinstallerdocumentationwillbecompleted
Continuedoperationofdampersandsmokecontroldeviceswillbeverified
Flowsandpressureswillbemeasuredandbalanced
Objective(s):Ensuretheperformanceoftheventilationsystem
Ensureoccupanthealthandsafety
AirSealing>Ducts>DuctSealing3.1602.15j-Combustionappliancezonetesting
3.1602.15j-CombustionappliancezonetestingDesiredOutcome:Improvedeffectivenessandefficiencyofventilationdistributionsystem
Specification(s):Pressureeffectscausedbyfanswillbeassessedandcorrectedwhenfoundoutsideofcombustionsafetystandards
Objective(s):Ensuresafeoperationofcombustionappliances
AirSealing>Ducts>DuctSealing3.1602.15k-Occupant/propertymanagereducation
3.1602.15k-Occupant/propertymanagereducationDesiredOutcome:Improvedeffectivenessandefficiencyofventilationdistributionsystem
Specification(s):Occupant/propertymanagerwillbeeducatedonhowthesystemworksanditspurpose
Occupant/propertymanagerwillbeinstructedtonotalterormakeholesintheventilationductsystem
Objective(s):Ensurethedurabilityoftheventilationsystem
AirSealing>Ducts>DuctSealing
3.1602.16-ForcedAir—AirSealingSystem—LowRiseDesiredOutcome:Ductsandplenumsaresealedtopreventleakage
Note:
AirSealing>Ducts>DuctSealing3.1602.16a-Newcomponenttonewcomponentsealantselection
3.1602.16a-NewcomponenttonewcomponentsealantselectionDesiredOutcome:Ductsandplenumsaresealedtopreventleakage
Specification(s):Anyclosuresystemusedwillmeetorexceedapplicablestandards
Objective(s):Ensureeffectivenessofairsealingsystem
AirSealing>Ducts>DuctSealing3.1602.16b-Newcomponenttoexistingcomponent
3.1602.16b-NewcomponenttoexistingcomponentDesiredOutcome:Ductsandplenumsaresealedtopreventleakage
Specification(s):Seams,cracks,joints,holes,andpenetrationslessthan1/4"willbesealedusingfiberglassmeshandmastic
Masticalonewillbeacceptableforholeslessthan1/4"thataremorethan10'fromairhandler
Seams,cracks,joints,holes,andpenetrationsbetween1/4"and3/4"willbesealedintwostages:
Theywillbebackedusingtemporarytape(e.g.,ducttape)asasupportpriortosealingTheywillbesealedusingfiberglassmeshandmastic
Objective(s):Eliminateairleakageintooroutofductsandplenums
Ensureadhesionofprimaryseal(fiberglassmeshandmastic)totheduct
Reinforcetheseal
Supportthemasticandfiberglassmeshduringcuring
AirSealing>Ducts>DuctSealing3.1602.16c-Existingcomponenttoexistingcomponent
3.1602.16c-ExistingcomponenttoexistingcomponentDesiredOutcome:Ductsandplenumsaresealedtopreventleakage
Specification(s):Fiberglassmeshandmasticwilloverlaptemporarytapebyatleast1"onallsides
Fiberglassmeshandmasticwillbecometheprimaryseal
Seams,cracks,joints,holes,andpenetrationslargerthan3/4"willberepairedusingrigidductmaterial
Objective(s):Eliminateairleakageintooroutofductsandplenums
Ensureadhesionofprimaryseal(fiberglassmeshandmastic)totheduct
Reinforcetheseal
Supportthemasticandfiberglassmeshduringcuring
AirSealing>Ducts>DuctSealing
3.1602.17-ForcedAir—AirSealingSystemComponents—LowRiseDesiredOutcome:Ductsandplenumsaresealedtopreventleakage
Note:
AirSealing>Ducts>DuctSealing3.1602.17a-Ductboottointeriorsurface
3.1602.17a-DuctboottointeriorsurfaceDesiredOutcome:Ductsandplenumsaresealedtopreventleakage
Specification(s):Gapsbetweenbootandgypsumlessthana1/4"willbesealedusingmastic
Gypsumedgewillbewettedbeforeapplyingmastic
Objective(s):Preventairleakage
AirSealing>Ducts>DuctSealing3.1602.17b-Woodenplenumsandbuildingcavities
3.1602.17b-WoodenplenumsandbuildingcavitiesDesiredOutcome:Ductsandplenumsaresealedtopreventleakage
Specification(s):Accessibleconnectionsandjointswillbemadeairtightusingapprovedmaterial
Objective(s):Ensureductsandplenumswillnotleakoutoforintoreturnorsupplyplenumsandducts
AirSealing>Ducts>DuctSealing3.1602.17c-Airhandlercabinet
3.1602.17c-AirhandlercabinetDesiredOutcome:Ductsandplenumsaresealedtopreventleakage
Specification(s):Jointswillbeclosed
Cracksandholesnotneededforproperfunctionandserviceofunitwillbesealedusingremovablesealant(e.g.,UL181approvedmastictape)
Objective(s):Reduceairleakagewhilemaintainingaccessibility
AirSealing>Ducts>DuctSealing3.1602.17d-Filterslot
3.1602.17d-FilterslotDesiredOutcome:Ductsandplenumsaresealedtopreventleakage
Specification(s):Apre-manufacturedorsite-manufactureddurableandairtightfilterslotcoverwillbeinstalled
Objective(s):Reduceairleakagewhilemaintainingaccessibility
AirSealing>Ducts>DuctSealing
3.1602.18-FramedPlatform—LowRiseDesiredOutcome:Thereturnductinstalledpreventsairleakage
Note:
AirSealing>Ducts>DuctSealing3.1602.18a-Preparation
3.1602.18a-PreparationDesiredOutcome:Thereturnductinstalledpreventsairleakage
Specification(s):Debrisanddirtwillbecleanedoutofthereturnplatform
Ensuretheplatformwillsupporttheweightoftheequipment
Objective(s):Allowfortheapplicationofrigidmaterialsandsealants
AirSealing>Ducts>DuctSealing3.1602.18b-Infillandbacking
3.1602.18b-InfillandbackingDesiredOutcome:Thereturnductinstalledpreventsairleakage
Specification(s):Backingorinfillwillbeprovidedasneededtomeetthespecificcharacteristicsoftheselectedmaterialandthecharacteristicsoftheopenspace
Backingorinfillwillnotbend,sag,ormoveonceinstalled
Materialwillberatedforuseinreturnductsystems
Objective(s):Minimizetheholesizetoensuresuccessfuluseofsealant
Ensuretheclosureispermanentandsupportsanyload(e.g.,returnairpressure)
Ensurethesealantdoesnotfallout
AirSealing>Ducts>DuctSealing3.1602.18c-Sealantselection
3.1602.18c-SealantselectionDesiredOutcome:Thereturnductinstalledpreventsairleakage
Specification(s):
Sealantswillbecompatiblewiththeirintendedsurfaces
Sealantswillbecontinuousandmeetfirebarrierspecifications
Objective(s):Selectpermanentsealant
Ensurethatsealantmeetsorexceedstheperformancecharacteristicsofthesurroundingmaterials
AirSealing>Roofs>Roof/WallConnections
3.1802.1-Roof/ExteriorWallConnection,IncludingJointsatRoof/Parapet/WallConnectionsDesiredOutcome:Continuousairbarrierbetweenroofandexteriorwallswhereconnectioniswithinconditionedspace
AirSealing>Roofs>Roof/WallConnections3.1802.1a-Pre-inspection
3.1802.1a-Pre-inspectionDesiredOutcome:Continuousairbarrierbetweenroofandexteriorwallswhereconnectioniswithinconditionedspace
Specification(s):Conductpre-inspectioninaccordancewithSWS2.0100.4WorkAreaInspectionandStabilization
Existingwatercontrolmeasureswillbeidentified
Airsealinglocationswillbeidentifiedbetweentheroofandtheexteriorwall
Objective(s):Provideasafeandstableworkenvironment
Avoidcompromisingexistingwatercontrolsystem
Ensureacontinuousairbarrierwillbeappropriatelylocatedattheroof/exteriorwalljunction
AirSealing>Roofs>Roof/WallConnections3.1802.1b-Backingandinfill
3.1802.1b-BackingandinfillDesiredOutcome:Continuousairbarrierbetweenroofandexteriorwallswhereconnectioniswithinconditionedspace
Specification(s):Wheregaps,cracks,orholesarelargerthan1/4"acrossand/orwheretheairsealingmaterialswillbesubjecttotemperaturevariationsinexcessof50°F,theneedforbackingorinfillwillbeevaluated
Ifused,backingorinfillwillmeetspecificcharacteristicsofthefire-resistance-ratedassembly,andbecompatiblewiththecharacteristicsofthegap,crack,orhole,includingpreservationofanyexpansion/contractioncharacteristicsforassembly(e.g.,expansionjoints,steampipes,ordissimilarmaterialinterfaceswithdifferingcoefficientsofexpansion)
Backingorinfillwillbeselectedthatmaintainssealantplacementanddurabilitywhileallowingfortheexpectedmovementfromexpansion,contraction,loaddeflection,settlingatthelocation,orifexistingwatercontrolmeasuresarecompromised(e.g.,rainscreen,dripedge,weepholes,gutterandroofdrains,scuppers,orotherexteriorwatermanagementelements)
Objective(s):Minimizegaporholesizetoensuresuccessfuluseofsealant
Ensureclosureispermanentandsupportsappropriateload(e.g.,wind,snow,insulation)
Ensuresealantdoesnotfallout
Ensureintegrityoftheexistingwatercontrolsystem
AirSealing>Roofs>Roof/WallConnections3.1802.1c-Sealantselection
3.1802.1c-SealantselectionDesiredOutcome:Continuousairbarrierbetweenroofandexteriorwallswhereconnectioniswithinconditionedspace
Specification(s):Sealantswillbecompatiblewiththeirintendedsurfacesandappliedinaccordancewithmanufacturerspecifications
Selectionwillbedurable,pestresistant,andhaveaweather-appropriateseal
Indoorsealantswillbelowvolatileorganiccompound(VOC)productsthatmeetindependenttestingandverificationprotocols,suchasGreenSealGS-36,"GREENGUARDChildrenandSchools,"orcomparablecertifications
Fire-resistance-ratedassemblieswillbeprovidedwithsealantspermittedbytheauthorityhavingjurisdictionandadoptedbuildingcode
Objective(s):Preventintrusionofmoistureandpestsintothesealedassembly
PreventexposingworkersoroccupantstoexcessiveVOClevels
Ensuresealantmeetsorexceedstheperformancecharacteristicsoftheassemblyandiscompliantwithlocalfirecoderequirements
AirSealing>Roofs>Roof/WallConnections3.1802.1d-Jointseal
3.1802.1d-JointsealDesiredOutcome:Continuousairbarrierbetweenroofandexteriorwallswhereconnectioniswithinconditionedspace
Specification(s):Continuoussealwillbeinstalledatroof/exteriorwalljunctionsorroof/exteriorandwall/parapetjunctions,including,butnotlimitedto,beams,cracks,joints,edges,penetrations,andconnections
Formetalroofdecks,fluteswillbeaccessedtoinstallsealantbetweentopsideofroofdeckandroofassembly
Objective(s):Provideairtight,durablesealthatdoesnotmove,bend,orsag
Ensurehiddenflutesareproperlysealed
AirSealing>Roofs>Roof/WallConnections3.1802.1e-Cavityseal
3.1802.1e-CavitysealDesiredOutcome:Continuousairbarrierbetweenroofandexteriorwallswhereconnectioniswithinconditionedspace
Specification(s):Forframedparapetsthatareopenbetweenconditionedandunconditionedspace,theparapet/wallcavitywillbeaccessed,andaninternalairbarrierwillbecreatedwithintheparapetwallcavityattheroofplane
Forparapetwallsconstructedwithhollowcoreconcretemasonryunits,thehollowcoreswillbeaccessedatthe
roofplane,andaninternalairbarrierwillbecreatedwithintheparapetwallcavityattheroofplane
Forexteriorinsulatedfinishingsystem(EIFS)parapet,airsealingmeasureswillpreservedesignedmoisturecontrolgapsbetweenEIFSandwallsheathing
Objective(s):Stopairmovementwithintheparapet/wallcavitytocreateacontinuousairbarrierattheroofplane
Provideairtight,durablesealthatdoesnotmove,bend,orsag
AirSealing>Roofs>Roof/WallConnections
3.1802.2-ExteriorOverhangsCommunicatingtoorThroughPressureBoundaryDesiredOutcome:Rigid,airtightcontinuousairbarrieratoverhang/wallinterface
Note:
AirSealing>Roofs>Roof/WallConnections3.1802.2a-Workersafety
3.1802.2a-WorkersafetyDesiredOutcome:Rigid,airtightcontinuousairbarrieratoverhang/wallinterface
Specification(s):AllworkersafetyspecificationswillbeinaccordancewithSWS2.0100.3WorkerSafety
Objective(s):Ensureworkersafety,especiallyinregardtofallprotectionconsiderationsandcontaminantsfoundindemolition,suchasasbestos,lead,polychlorinatedbiphenyls,etc.
AirSealing>Roofs>Roof/WallConnections3.1802.2b-Occupantsafety
3.1802.2b-OccupantsafetyDesiredOutcome:Rigid,airtightcontinuousairbarrieratoverhang/wallinterface
Specification(s):Occupantwillbenotifiedofchangesorrepairstobemade
Anoccupantsafetyplanwillbepreparedandimplemented
Objective(s):Ensureoccupantsafety
AirSealing>Roofs>Roof/WallConnections3.1802.2c-Pre-inspection
3.1802.2c-Pre-inspectionDesiredOutcome:Rigid,airtightcontinuousairbarrieratoverhang/wallinterface
Specification(s):Conductpre-inspectioninaccordancewithSWS2.0100.4WorkAreaInspectionandStabilization
Gaps,cracks,andholesinfireseparationslocatedwithintheworkareawillbevisuallyidentifiedandincorporatedintoairsealingworkscope,includingthosethatspantwoconditionedorunconditionedspaces
Wheredrawingsareavailablethatidentifyspecificfire-resistance-ratings(i.e.,1hour,2hour),materialsand
methodswillbeemployedtopreserveorrestoresuchrating
Wheredrawingsareunavailableordonotidentifyspecificfire-resistanceratings,thefire-resistanceratingoftheassemblymaybeinferredfromthecurrentconstruction(i.e.,single5/8sheetrock,concretemasonryunit),andmaterialsandmethodsemployedwillbeconsistentwithrestoringorpreservingsuchinferredfire-resistancerating
Identifyoverhanglocationstodeterminedesiredlocationofairbarrier,determineholesize,framing,andmaterialrequirements(includingfirerating)
Objective(s):Provideasafeandstableworkenvironment
Ensureadurable,continuousairbarrierandafireassembly,whereappropriate
AirSealing>Roofs>Roof/WallConnections3.1802.2d-Site
3.1802.2d-SiteDesiredOutcome:Rigid,airtightcontinuousairbarrieratoverhang/wallinterface
Specification(s):Itemsandpropertybelowandadjacenttoworkareawillberemovedfromtheworkareasorwillbeadequatelyprotected
Objective(s):Preventdamagetoobjectsneartheworkandworkers
AirSealing>Roofs>Roof/WallConnections3.1802.2e-Backingandinfill
3.1802.2e-BackingandinfillDesiredOutcome:Rigid,airtightcontinuousairbarrieratoverhang/wallinterface
Specification(s):Wheregaps,cracks,orholesarelargerthan1/4"acrossand/orwheretheairsealingmaterialswillbesubjecttotemperaturevariationsinexcessof50°F,theneedforbackingorinfillwillbeevaluated
Ifused,backingorinfillwillmeetspecificcharacteristicsofthefire-resistance-ratedassembly,andbecompatiblewiththecharacteristicsofthegap,crack,orhole,includingpreservationofanyexpansion/contractioncharacteristicsforassembly(e.g.,expansionjoints,steampipes,ordissimilarmaterialinterfaceswithdifferingcoefficientsofexpansion)
Backingorinfillwillbeselectedthatmaintainssealantplacementanddurabilitywhileallowingfortheexpectedmovementfromexpansion,contraction,loaddeflection,settlingatthelocation,orifexistingwatercontrolmeasuresarecompromised(e.g.,rainscreen,dripedge,weepholes,gutterandroofdrains,scuppers,orotherexteriorwatermanagementelements)
Objective(s):Minimizegaporholesizetoensuresuccessfuluseofsealant
Ensureclosureisdurable,pestresistant,weatherappropriate,andsupportsappropriateload(e.g.,wind,snow,insulation)
Ensuresealantdoesnotfallout
Ensureintegrityoftheexistingwatercontrolsystem
AirSealing>Roofs>Roof/WallConnections3.1802.2f-Sealantselection
3.1802.2f-SealantselectionDesiredOutcome:Rigid,airtightcontinuousairbarrieratoverhang/wallinterface
Specification(s):Sealantswillbecompatiblewiththeirintendedsurfacesandappliedinaccordancewithmanufacturerspecifications
Selectionwillbedurable,pestresistant,andhaveaweather-appropriateseal
Indoorsealantswillbelowvolatileorganiccompound(VOC)productsthatmeetindependenttestingandverificationprotocols,suchasGreenSealGS-36,"GREENGUARDChildrenandSchools,"orcomparablecertifications
Fire-resistance-ratedassemblieswillbeprovidedwithsealantspermittedbytheauthorityhavingjurisdictionandadoptedbuildingcode
Objective(s):Preventintrusionofmoistureandpestsintothesealedassembly
PreventexposingworkersoroccupantstoexcessiveVOClevels
Ensuresealantmeetsorexceedstheperformancecharacteristicsoftheassemblyandiscompliantwithlocalfirecoderequirements
AirSealing>Roofs>Roof/WallConnections3.1802.2g-Airbarrier
3.1802.2g-AirbarrierDesiredOutcome:Rigid,airtightcontinuousairbarrieratoverhang/wallinterface
Specification(s):Attheoverhang,acontinuousairbarrierwillbecreatedtoalignwiththewallairbarrier
Theopeningwillbeclosedoffwitharigidmaterialthatmeetsassemblyfirerating
Theairbarrierwillbefastenedtoframingasappropriate
Rigidmaterialandallopeningswillbesealedtoformacompleteairbarrier
Objective(s):Preventairleakagebycreatingadurableairbarriercontinuouswiththewallairbarrier
Ensurematerialisabletosupportwindandinsulationloads
Ensurefinalgapissealedwithappropriatesealant
AirSealing>Roofs>Roof/WallConnections3.1802.2h-Qualityassurance
3.1802.2h-QualityassuranceDesiredOutcome:Rigid,airtightcontinuousairbarrieratoverhang/wallinterface
Specification(s):OverhangwillbevisuallyinspectedandtestedforairtightnessinaccordancewithASTME1186-03
Watermanagementsystemswillbeverifiedasmaintained
Objective(s):Preventairleakagethroughassembly
Preventwaterintrusion
AirSealing>Roofs>Roof/WallConnections3.1802.2i-Ignitionbarrier/fireproofing
3.1802.2i-Ignitionbarrier/fireproofingDesiredOutcome:Rigid,airtightcontinuousairbarrieratoverhang/wallinterface
Specification(s):Whererigidfoamplasticsareused,innocasewillthefinalthicknessexceedthemanufacturer'stestedthicknessusedtodeterminethemaximum75flamespreadand450smoke-developedindexwhentestedtoASTME84orUL723
Foam,wherepermissible,willbeprovidedwithignitionandthermalbarriersasrequiredbycode
Otherfirestopmaterialsmayberequiredforfireresistance-ratedwallswithopeningsrequiredtobeprotected
Objective(s):Complywithlocalcodesandordinances
AirSealing>Compartmentalization>MultifamilyCompartmentalizationTechniques
3.1901.1-GeneralCompartmentalizationTechniquesDesiredOutcome:Effectiveairbarrierbetweenidentifiedisolatedandotherconditionedspacesofthebuilding
Note:
AirSealing>Compartmentalization>MultifamilyCompartmentalizationTechniques3.1901.1a-Pre-inspection
3.1901.1a-Pre-inspectionDesiredOutcome:Effectiveairbarrierbetweenidentifiedisolatedandotherconditionedspacesofthebuilding
Specification(s):Conductpre-inspectioninaccordancewithSWS2.0100.4WorkAreaInspectionandStabilization
Gaps,cracks,andholesinfireseparationslocatedwithintheworkareawillbevisuallyidentifiedandincorporatedintoairsealingworkscope,includingthosethatspantwoconditionedorunconditionedspaces
Wheredrawingsareavailablethatidentifyspecificfire-resistanceratings(i.e.,1hour,2hour),materialsandmethodswillbeemployedtopreserveorrestoresuchrating
Wheredrawingsareunavailableordonotidentifyspecificfire-resistanceratings,thefire-resistanceratingoftheassemblymaybeinferredfromthecurrentconstruction(i.e.,single5/8sheetrock,concretemasonryunit),andmaterialsandmethodsemployedwillbeconsistentwithrestoringorpreservingsuchinferredfire-resistancerating
Repairsnecessarytostabilizeworkareas,andprotectorpreserveintegrityofenergyimprovementwillbecompletedbeforesubjectworkbegins
Objective(s):Provideasafeandstableworkenvironment
Repairoraddressmoisture,structure,andpest-relatedissues
Ensurethatfireseparationsarepreserved
AirSealing>Compartmentalization>MultifamilyCompartmentalizationTechniques3.1901.1b-Identificationofpenetrations
3.1901.1b-IdentificationofpenetrationsDesiredOutcome:Effectiveairbarrierbetweenidentifiedisolatedandotherconditionedspacesofthebuilding
Specification(s):Penetrationswillbeidentifiedusingvisualinspections,infraredthermography,smoke,and/orpressuretests(ASTME1186-03[2009])
Objective(s):Locateairleakagepathwaystorepair
AirSealing>Compartmentalization>MultifamilyCompartmentalizationTechniques3.1901.1c-Preparation
3.1901.1c-PreparationDesiredOutcome:Effectiveairbarrierbetweenidentifiedisolatedandotherconditionedspacesofthebuilding
Specification(s):Healthandsafetyconcernswillbeaddressedforoccupantsandworkers,inrelationtorepairsandmaterials,willbeaddressedinaccordancewithOSHAstandards(OSHA1926,1910)
Theareawillbepreparedandisolatedinaccordancewithhealthandsafetystandardsfortheapplicationandmaterials(e.g.,extremetemperatures,lead,asbestos)
Worklighting,workplatform,andadequateventilationwillbeprovided
Objective(s):Provideasafeworkenvironment
Providesafeindoorenvironmentalquality(IEQ)workintheworkenvironment
Provideeffectiverepairaccess
AirSealing>Compartmentalization>MultifamilyCompartmentalizationTechniques3.1901.1d-Sealantandmaterialsselection
3.1901.1d-SealantandmaterialsselectionDesiredOutcome:Effectiveairbarrierbetweenidentifiedisolatedandotherconditionedspacesofthebuilding
Specification(s):Sealantsandmaterialswillbecompatiblewiththeirintendedsurfacesandappliedinaccordancewithmanufacturerspecifications
Selectionwillbedurable,pestresistant,andhaveaweather-appropriateseal
Indoorsealantswillbelowvolatileorganiccompound(VOC)productsthatmeetindependenttestingandverificationprotocols,suchasGreenSealGS-36,"GREENGUARDChildrenandSchools,"orcomparablecertifications
Fire-resistance-ratedassemblieswillbeprovidedwithsealantspermittedbytheauthorityhavingjurisdictionandadoptedbuildingcode
Objective(s):Preventintrusionofmoistureandpestsintothesealedassembly
PreventexposingworkersoroccupantstoexcessiveVOClevels
Ensuresealantmeetsorexceedstheperformancecharacteristicsoftheassemblyandiscompliantwithlocalfirecoderequirements
AirSealing>Compartmentalization>MultifamilyCompartmentalizationTechniques3.1901.1e-Verification
3.1901.1e-VerificationDesiredOutcome:Effectiveairbarrierbetweenidentifiedisolatedandotherconditionedspacesofthebuilding
Specification(s):Repairswillbeverifiedbyvisualinspections,infraredthermography,smoke,and/orpressuretestsconsistentwith
thepre-inspection
Objective(s):Ensurequalityandeffectivenessofairsealing
AirSealing>Compartmentalization>MultifamilyCompartmentalizationTechniques
3.1901.2-Performance-BasedAirSealingofDwellingUnitsandCorridorsDesiredOutcome:Controlofoneormoreofthefollowing:buildingairleakage,stackeffect,noisetransmission,orimprovedindoorairquality
Note:
AirSealing>Compartmentalization>MultifamilyCompartmentalizationTechniques3.1901.2a-Pre-inspection
3.1901.2a-Pre-inspectionDesiredOutcome:Controlofoneormoreofthefollowing:buildingairleakage,stackeffect,noisetransmission,orimprovedindoorairquality
Specification(s):Conductpre-inspectioninaccordancewithSWS2.0100.4WorkAreaInspectionandStabilization
Gaps,cracks,andholesinfireseparationslocatedwithintheworkareawillbevisuallyidentifiedandincorporatedintoairsealingworkscope,includingthosethatspantwoconditionedorunconditionedspaces
Wheredrawingsareavailablethatidentifyspecificfire-resistanceratings(i.e.,1hour,2hour),materialsandmethodswillbeemployedtopreserveorrestoresuchrating
Wheredrawingsareunavailableordonotidentifyspecificfire-resistanceratings,thefire-resistanceratingoftheassemblymaybeinferredfromthecurrentconstruction(i.e.,single5/8sheetrock,concretemasonryunit),andmaterialsandmethodsemployedwillbeconsistentwithrestoringorpreservingsuchinferredfire-resistancerating.
Workorderrepairsrequiringaccesstodwellingunitswillbereviewedwithallrelevantauthorities(e.g.,buildingmanagement,propertymanagement)
Accesstoworkareaswithindwellingunitswillbeobtained
Repairsnecessarytostabilizeworkareasandprotectorpreserveintegrityofenergyimprovementwillbecompletedbeforesubjectworkbegins
Objective(s):Provideasafeandstableworkenvironment
Repairoraddressmoisture,pest,andstructure-relatedissues
Obtainaccesstounitsandworkareaswithindwellingunits
AirSealing>Compartmentalization>MultifamilyCompartmentalizationTechniques3.1901.2b-Workcoordinationamongtrades
3.1901.2b-WorkcoordinationamongtradesDesiredOutcome:Controlofoneormoreofthefollowing:buildingairleakage,stackeffect,noisetransmission,orimprovedindoorairquality
Specification(s):Workwillbecoordinatedwithallothertradesperformingworkincompartmentalizedspacestoscheduleanyrequiredsystemwidetest-outverification
Objective(s):Ensuresystemwideairsealingandpressureboundarybenefitswillbeachieved
AirSealing>Compartmentalization>MultifamilyCompartmentalizationTechniques3.1901.2c-Preparation
3.1901.2c-PreparationDesiredOutcome:Controlofoneormoreofthefollowing:buildingairleakage,stackeffect,noisetransmission,orimprovedindoorairquality
Specification(s):Healthandsafetyconcernsforoccupantsandworkers,inrelationtorepairsandmaterials,willbeaddressedinaccordancewithOSHAstandards(OSHA1926,1910)
Theareawillbepreparedandisolatedinaccordancewithhealthandsafetystandardsfortheapplicationandmaterials(e.g.,extremetemperatures,lead,asbestos)
Worklighting,workplatform,andadequateventilationwillbeprovided
Objective(s):Provideasafeworkenvironment
Provideasafeindoorenvironmentalquality(IEQ)intheworkenvironment
Provideeffectiverepairaccess
AirSealing>Compartmentalization>MultifamilyCompartmentalizationTechniques3.1901.2d-Identificationofpenetrations
3.1901.2d-IdentificationofpenetrationsDesiredOutcome:Controlofoneormoreofthefollowing:buildingairleakage,stackeffect,noisetransmission,orimprovedindoorairquality
Specification(s):Penetrationswillbeidentifiedusingvisualinspections,infraredthermography,smoke,and/orpressuretests(ASTME1186-03[2009])
Note:Workwillpreserveexistingventilationperformance,includingapartmentdoorundercuts,whereexistingcentralventilationdesignincorporatestheseundercutsasanintentionalpathwayfromhallwaystoapartments
Objective(s):Establishbaselineairleakage
Identifyairleakagerepairlocations
Monitorrepairprogress
PreserveIEQforoccupants
AirSealing>Compartmentalization>MultifamilyCompartmentalizationTechniques3.1901.2e-Installation,sealant,andmaterialsselection
3.1901.2e-Installation,sealant,andmaterialsselectionDesiredOutcome:Controlofoneormoreofthefollowing:buildingairleakage,stackeffect,noisetransmission,orimprovedindoorairquality
Specification(s):Sealantsandmaterialswillbecompatiblewiththeirintendedsurfacesandappliedinaccordancewithmanufacturerspecifications
Selectionwillbedurable,pestresistant,andhaveaweather-appropriateseal
Indoorsealantswillbelowvolatileorganiccompound(VOC)productsthatmeetindependenttestingandverificationprotocols,suchasGreenSealGS-36,"GREENGUARDChildrenandSchools,"orcomparablecertifications
Fire-resistance-ratedassemblieswillbeprovidedwithsealantspermittedbytheauthorityhavingjurisdictionandadoptedbuildingcode
Objective(s):Preventintrusionofmoistureandpestsintothesealedassembly
PreventexposingworkersoroccupantstoexcessiveVOClevels
Ensuresealantmeetsorexceedstheperformancecharacteristicsoftheassemblyandiscompliantwithlocalfirecoderequirements
AirSealing>Compartmentalization>MultifamilyCompartmentalizationTechniques3.1901.2f-Verification
3.1901.2f-VerificationDesiredOutcome:Controlofoneormoreofthefollowing:buildingairleakage,stackeffect,noisetransmission,orimprovedindoorairquality
Specification(s):Repairswillbeverifiedbypressuretestsconsistentwiththepre-inspection
Anypressurebalancetest-outverificationwillbeperformedafterallworkfromalltradesiscompleted
Objective(s):Ensurequalityandeffectivenessofairsealing
Meetperformancespecifications
AirSealing>Compartmentalization>MultifamilyCompartmentalizationTechniques3.1901.2g-Propertymanager/occupanteducation
3.1901.2g-Propertymanager/occupanteducationDesiredOutcome:Controlofoneormoreofthefollowing:buildingairleakage,stackeffect,noisetransmission,orimprovedindoorairquality
Specification(s):Documentationofmaterialandmaintenancerequirementswillbeprovidedtopropertymanager/occupant,asappropriate
Objective(s):
Properlymaintainthesystem
AirSealing>Compartmentalization>MultifamilyCompartmentalizationTechniques
3.1901.3-ChaseWays(e.g.,ServiceSpacesContainingPipes,Wires,Ducts,and/orStructuralComponents;IncludesDumbwaitersandTrashChutes)DesiredOutcome:Controlofoneormoreofthefollowing:buildingairleakage,stackeffect,noisetransmission,orimprovedindoorairquality
Note:
AirSealing>Compartmentalization>MultifamilyCompartmentalizationTechniques3.1901.3a-Pre-inspection
3.1901.3a-Pre-inspectionDesiredOutcome:Controlofoneormoreofthefollowing:buildingairleakage,stackeffect,noisetransmission,orimprovedindoorairquality
Specification(s):Conductpre-inspectioninaccordancewithSWS2.0100.4WorkAreaInspectionandStabilization
Gaps,cracks,andholesinfireseparationslocatedwithintheworkareawillbevisuallyidentifiedandincorporatedintoairsealingworkscope,includingthosethatspantwoconditionedorunconditionedspaces
Wheredrawingsareavailablethatidentifyspecificfire-resistanceratings(i.e.,1hour,2hour),materialsandmethodswillbeemployedtopreserveorrestoresuchrating
Wheredrawingsareunavailableordonotidentifyspecificfire-resistanceratings,thefire-resistanceratingoftheassemblymaybeinferredfromthecurrentconstruction(i.e.,single5/8sheetrock,concretemasonryunit),andmaterialsandmethodsemployedwillbeconsistentwithrestoringorpreservingsuchinferredfire-resistancerating
Repairsnecessarytostabilizeworkareasandprotectorpreserveintegrityofenergyimprovementwillbecompletedbeforesubjectworkbegins
Objective(s):Provideasafeandstableworkenvironment
Repairmoistureandstructure-relatedissues
AirSealing>Compartmentalization>MultifamilyCompartmentalizationTechniques3.1901.3b-Identificationofpenetrations
3.1901.3b-IdentificationofpenetrationsDesiredOutcome:Controlofoneormoreofthefollowing:buildingairleakage,stackeffect,noisetransmission,orimprovedindoorairquality
Specification(s):Penetrationswillbeidentifiedusingvisualinspections,infraredthermography,smoke,and/orpressuretests(ASTME1186-03[2009])
Accesswillbeprovidedtoensurethatrepairscanbemade(mayincludelocalizeddemolition)
Attemptswillbemadetosecureexistingbuildingdrawingsandspecificationsrelatingtoaffectedareastoaidindiagnosticsandminimizetemporarydemolition
Fire-resistantintegrityofexistingshaftsthatspanmultiplefireseparationswillbemaintainedduringtestingand
constructionperiods
Objective(s):Locateairleakagepathwaystorepair
Providesystem-wideairflowcontrolbenefits
Ensurethatbreechesoffire-separatedspacesarenotleftunattendedduringtheconstructioncycle
AirSealing>Compartmentalization>MultifamilyCompartmentalizationTechniques3.1901.3c-Preparation
3.1901.3c-PreparationDesiredOutcome:Controlofoneormoreofthefollowing:buildingairleakage,stackeffect,noisetransmission,orimprovedindoorairquality
Specification(s):Healthandsafetyconcernsforoccupantsandworkers,inrelationtorepairsandmaterials,willbeaddressedinaccordancewithOSHAstandards(OSHA1926,1910)
Theareawillbepreparedandisolatedinaccordancewithhealthandsafetystandardsfortheapplicationandmaterials(e.g.,extremetemperatures,lead,asbestos)
Worklighting,workplatform,andadequateventilationwillbeprovided
Objective(s):Provideasafeworkenvironment
Providesafeindoorenvironmentalquality(IEQ)intheworkenvironment
Provideeffectiverepairaccess
AirSealing>Compartmentalization>MultifamilyCompartmentalizationTechniques3.1901.3d-Installation,sealant,andmaterialsselection
3.1901.3d-Installation,sealant,andmaterialsselectionDesiredOutcome:Controlofoneormoreofthefollowing:buildingairleakage,stackeffect,noisetransmission,orimprovedindoorairquality
Specification(s):Sealantsandmaterialswillbecompatiblewiththeirintendedsurfacesandappliedinaccordancewithmanufacturerspecifications
Selectionwillbedurable,pestresistant,andhaveaweather-appropriateseal
Indoorsealantswillbelowvolatileorganiccompound(VOC)productsthatmeetindependenttestingandverificationprotocols,suchasGreenSealGS-36,"GREENGUARDChildrenandSchools,"orcomparablecertifications
Fire-resistance-ratedassemblieswillbeprovidedwithsealantspermittedbytheauthorityhavingjurisdictionandadoptedbuildingcode
Objective(s):Preventintrusionofmoistureandpestsintothesealedassembly
PreventexposingworkersoroccupantstoexcessiveVOClevels
Ensuresealantmeetsorexceedstheperformancecharacteristicsoftheassemblyandiscompliantwithlocalfirecoderequirements
AirSealing>Compartmentalization>MultifamilyCompartmentalizationTechniques3.1901.3e-Demolitionrepair
3.1901.3e-DemolitionrepairDesiredOutcome:Controlofoneormoreofthefollowing:buildingairleakage,stackeffect,noisetransmission,orimprovedindoorairquality
Specification(s):Accessholeswillberepaired
Bothtemporary(duringconstruction)andpermanentdemolitionrepairswillpreservethefire-resistanceratingsofaffectedassemblies
Objective(s):Restoresurfacestooriginalconditionorbetter
AirSealing>Compartmentalization>MultifamilyCompartmentalizationTechniques3.1901.3f-Verification
3.1901.3f-VerificationDesiredOutcome:Controlofoneormoreofthefollowing:buildingairleakage,stackeffect,noisetransmission,orimprovedindoorairquality
Specification(s):Repairswillbeverifiedbyvisualinspections,infraredthermography,smoke,and/orpressuretestsconsistentwiththepre-inspection
Objective(s):Ensurequalityandeffectivenessofairsealing
Insulation>Attics>AtticCeilings
4.1003.14-AccessibleUnventedFlatRoofwithorwithoutExistingInsulationDesiredOutcome:Insulationreducesheatflowthroughunventedroof
Insulation>Attics>AtticCeilings4.1003.14a-Workersafety
4.1003.14a-WorkersafetyDesiredOutcome:Insulationreducesheatflowthroughunventedroof
Specification(s):AllworkersafetyspecificationswillbeinaccordancewithSWS2.0100.3WorkerSafety
Objective(s):Ensureworkersafety,especiallyinregardtofallprotectionconsiderationsandcontaminantsfoundindemolition,suchasasbestos,lead,polychlorinatedbiphenyls,etc.
Insulation>Attics>AtticCeilings4.1003.14b-Occupantsafety
4.1003.14b-OccupantsafetyDesiredOutcome:Insulationreducesheatflowthroughunventedroof
Specification(s):Anoccupantsafetyplanwillbepreparedandimplemented
Objective(s):Ensureoccupantsafety
Insulation>Attics>AtticCeilings4.1003.14c-Pre-inspection
4.1003.14c-Pre-inspectionDesiredOutcome:Insulationreducesheatflowthroughunventedroof
Specification(s):Conductpre-inspectioninaccordancewithSWS2.0100.4WorkAreaInspectionandStabilization
Insulationwillnotbeinstalledifmoisture-relatedissuesarenotresolved
Objective(s):Ensureadurable,continuousairandthermalboundary
Insulation>Attics>AtticCeilings4.1003.14d-Preparation
4.1003.14d-PreparationDesiredOutcome:Insulationreducesheatflowthroughunventedroof
Specification(s):Newinsulationthatisnotdesignedtoalsoserveasanairbarrierwillnotbeaddeduntilallairsealinghasbeencompleted
Existinginsulationwillbeinspectedtoconfirmthatitisnotconcealingairbarrierweaknesses,andisinfullcontactandalignmentwiththeairbarrier
Wheretheinsulationisdisturbedorfoundnottobeincontactwiththeairbarrier,itwillbereinstalledtobeincontactwiththeairbarrier;ifitcannotbereinstalledorifitsconditioncompromisesitseffectiveness,theinsulationwillberemoved
Insulationwillbemarkedfordepthaminimumofevery300squarefeetofatticareawithmeasurementbeginningattheairbarrier
Allelectricaljunctionswillbeflaggedtobeseenabovetheleveloftheinsulation
Coverswillbeinstalledonopenelectricaljunctionboxes
Insulationdamsandenclosures(e.g.,canlights,sprinklersystems,accesshatch,chimney)willbeinstalledasrequired
Whereloosefillorbattinsulationisused,itwillhaveamaximum25flamespread/50smoke-developedindexwhentestedtoASTME84orUL723
Whererigidfoamplasticsareused,innocasewillthefinalthicknessexceedthemanufacturer'stestedthicknessusedtodeterminethemaximum75flamespreadand450smoke-developedindexwhentestedtoASTME84orUL723
Foamwillbeprovidedwithignitionandthermalboundariesasrequiredbycode
Objective(s):Minimizepotentialforwarm,moistairtoentertheatticandcondenseoncoldsurfaces
Ensureproperperformanceofinsulation
Verifyuniformityofinsulationmaterial
Providelocationofelectricaljunctionsforfutureservicing
Preventanelectricalhazard
Insulation>Attics>AtticCeilings4.1003.14e-Installation
4.1003.14e-InstallationDesiredOutcome:Insulationreducesheatflowthroughunventedroof
Specification(s):Atticinsulationwillbeinstalledwithoutgaps,voids,compressions,misalignments,orwindintrusions
Roofcavitieswillbeblownwithloose-fillinsulationwithoutgaps,voids,compressions,misalignments,orwindintrusions
InsulationwillbeinstalledtoprescribedR-value
FinalR-valuewillaccountforthecompressionofexistinginsulation
Objective(s):InsulatetoprescribedR-value
Insulation>Attics>AtticCeilings4.1003.14f-Ventilation
4.1003.14f-VentilationDesiredOutcome:Insulationreducesheatflowthroughunventedroof
Specification(s):Codecompliantventilationwillbeinstalledbeforeinsulation
Objective(s):Reducepossibilityofmoistureissues
Insulation>Attics>AtticCeilings4.1003.14g-Occupanteducation
4.1003.14g-OccupanteducationDesiredOutcome:Insulationreducesheatflowthroughunventedroof
Specification(s):Adatedreceiptsignedbytheinstallerwillbeprovidedthatincludes:
Insulationtype
Coveragearea
R-value
Installedthicknessandminimumsettledthickness
NumberofbagsinstalledinaccordancewithmanufacturerspecificationsObjective(s):Documentjobcompletiontocontractspecifications
Confirmamountofinsulationinstalled
Ensureabilitytomatchbagsrequiredfortotalareacompleted
Complywith16CFR460.17
Insulation>Attics>AtticFloors
4.1005.8-LooseFillOverExistingInsulationonAccessibleAtticFloorsDesiredOutcome:Insulationcontrolsheattransferthroughceiling
Insulation>Attics>AtticFloors4.1005.8a-Preparation
4.1005.8a-PreparationDesiredOutcome:Insulationcontrolsheattransferthroughceiling
Specification(s):Newinsulationwillnotbeaddeduntilallairsealinghasbeencompleted
Existinginsulationwillbeinspectedtoconfirmthatitisnotconcealingairbarrierweaknessesandisinfullcontactandalignmentwiththeairbarrier
Wheretheinsulationisdisturbedorfoundnottobeincontactwiththeairbarrier,itwillbereinstalledtobeincontactwiththeairbarrier;ifitcannotbereinstalledorifitsconditioncompromisesitseffectiveness,theinsulationwillberemoved
Insulationwillbeadequatelymarkedfordepthaminimumofevery300squarefeetofatticareawithmeasurementbeginningattheairbarrier
Allelectricaljunctionswillbeflaggedtobeseenabovetheleveloftheinsulation
Openelectricaljunctionboxeswillhavecoversinstalled
Insulationdamsandenclosureswillbeinstalledasrequired
Blockingwillbeinstalledtomaintainexistingventedatticfunctionality
Objective(s):Ensureproperperformanceofinsulation
Verifyuniformityofinsulationmaterial
Providelocationofelectricaljunctionsforfutureservicing
Preventanelectricalhazard
Insulation>Attics>AtticFloors4.1005.8b-Installation
4.1005.8b-InstallationDesiredOutcome:Insulationcontrolsheattransferthroughceiling
Specification(s):Thecorrectdepthandnumberofbagswillbeblowninaccordancewithmanufacturerspecifications
InsulationwillbeinstalledtoprescribedR-value
FinalR-valuewillaccountforthecompressionofexistinginsulation
Objective(s):InsulatetoprescribedR-value
Insulation>Attics>AtticFloors4.1005.8c-Safety
4.1005.8c-SafetyDesiredOutcome:Insulationcontrolsheattransferthroughceiling
Specification(s):Insulationwillnotbeallowedontopofnon-insulationcontact(IC)-ratedcanlightboxesorbetweenaheat-generatingapplianceandadamunlessmaterialisratedforcontactwithheat-generatingsources
AllinsulationmaterialsusedwillmeetASTME84flamespread/smokedevelopmentratingof25/50
Objective(s):Preventafirehazard
Insulation>Attics>AtticFloors4.1005.8d-Onsitedocumentation
4.1005.8d-OnsitedocumentationDesiredOutcome:Insulationcontrolsheattransferthroughceiling
Specification(s):Adatedreceiptsignedbytheinstallerwillbeprovidedthatincludes:
Insulationtype
Coveragearea
R-value
Installedthicknessandminimumsettledthickness
NumberofbagsinstalledinaccordancewithmanufacturerspecificationsObjective(s):Documentjobcompletiontocontractspecifications
Confirmamountofinsulationinstalled
Ensureabilitytomatchbagsrequiredfortotalareacompleted
Complywith16CFR460.17
Insulation>Attics>SpecialConsiderations
4.1088.8-Installation/CorrectionofUnconditionedAtticVentilationDesiredOutcome:Properlyrestoredventsminimizemoistureandicedams
Insulation>Attics>SpecialConsiderations4.1088.8a-Pre-inspection
4.1088.8a-Pre-inspectionDesiredOutcome:Properlyrestoredventsminimizemoistureandicedams
Specification(s):Conductpre-inspectioninaccordancewithSWS2.0100.4WorkAreaInspectionandStabilization
Objective(s):Ensuresafety,effectiveness,anddurabilityofimprovements
Insulation>Attics>SpecialConsiderations4.1088.8b-Airbarrierandthermalboundary
4.1088.8b-AirbarrierandthermalboundaryDesiredOutcome:Properlyrestoredventsminimizemoistureandicedams
Specification(s):Atticventilationwillberecommendedorinstalledonlyif:
ThepresenceofaneffectiveairbarrierandthermalboundarybetweentheatticandthelivingspaceisverifiedAppropriateatticsealingandproperinsulationisspecifiedaspartoftheworkscopeIgnitionbarrierandthermalboundariesareprovidedwhenfoamplasticmaterialsareused
Objective(s):Ensurepresenceofcontinuousairbarrierandthermalboundary
Insulation>Attics>SpecialConsiderations4.1088.8c-Venttype
4.1088.8c-VenttypeDesiredOutcome:Properlyrestoredventsminimizemoistureandicedams
Specification(s):Atticventtypeswillbeconsistentwithrequirementsfortheirspecificlocation(e.g.,exteriorsoffit,gableend,roof)andmaterialandintendeduse(e.g.,metalventonmetalroof)
Ventilationopeningareaandconfigurationwillcomplywithapplicablebuildingcode
Objective(s):Ensureventmeetsproperperformancecharacteristicsforlocationandroofingtype
Insulation>Attics>SpecialConsiderations4.1088.8d-Ventlocation
4.1088.8d-VentlocationDesiredOutcome:Properlyrestoredventsminimizemoistureandicedams
Specification(s):Placementofatticventswillbeconsideredforproperairflowandpreventionofentryofwind-drivenrainorsnow
Objective(s):Encourageproperairflow
Minimizeentryofwind-drivenrainorsnow
Insulation>Attics>SpecialConsiderations4.1088.8e-Ventilationbaffling
4.1088.8e-VentilationbafflingDesiredOutcome:Properlyrestoredventsminimizemoistureandicedams
Specification(s):Bafflingforatticsoffitventswillbeinstalledto:
EnsureproperairflowPreventwindwashingofinsulationAllowmaximuminsulationcoverageEnsurebaffleterminatesaboveinsulation
Minimumclearancebetweeninsulationandroofdeckwillbe1"
Objective(s):Ensureventallowsproperairflowwithoutcompromisinginsulationperformance
Insulation>Attics>SpecialConsiderations4.1088.8f-Ventilationscreens
4.1088.8f-VentilationscreensDesiredOutcome:Properlyrestoredventsminimizemoistureandicedams
Specification(s):Allatticventilationwillhavescreenswithnoncorrodingwiremeshwithopeningsof1/8"topreventpestentry(e.g.,birds,bats,bees)
Existingventsthatarenotscreenedwillbecoveredwithnoncorrodingwiremeshwithopeningsof1/8"
Objective(s):Preventpestentry
Insulation>Walls>EnclosedWalls
4.1103.4-DensePackingBlownInsulationDesiredOutcome:Maintainaconsistent,uniformthermalandweather-resistantboundarybetweenconditionedandunconditionedspacetoprescribedR-valueofanadjoininginsulatedassembly
Insulation>Walls>EnclosedWalls4.1103.4a-Workersafety
4.1103.4a-WorkersafetyDesiredOutcome:Maintainaconsistent,uniformthermalandweather-resistantboundarybetweenconditionedandunconditionedspacetoprescribedR-valueofanadjoininginsulatedassembly
Specification(s):AllworkersafetyspecificationswillbeinaccordancewithSWS2.0100WorkerSafety
Leadsafetyproceduresinbuildingsbuiltbefore1978willbefollowed,unlessapprovedtestingmethodprovesabsenceofleadbasedpaintinsurfacesthatwillbedisturbed
Objective(s):Ensureworkersafety,especiallyinregardtofallprotectionconsiderationsandcontaminantsfoundindemolition,suchasasbestos,lead,polychlorinatedbiphenyls,etc.
Insulation>Walls>EnclosedWalls4.1103.4b-Occupantsafety
4.1103.4b-OccupantsafetyDesiredOutcome:Maintainaconsistent,uniformthermalandweather-resistantboundarybetweenconditionedandunconditionedspacetoprescribedR-valueofanadjoininginsulatedassembly
Specification(s):Occupantwillbenotifiedofchangesorrepairstobemade
Anoccupantsafetyplanwillbepreparedandimplemented
Objective(s):Ensureoccupantsafety
Insulation>Walls>EnclosedWalls4.1103.4c-Pre-inspection
4.1103.4c-Pre-inspectionDesiredOutcome:Maintainaconsistent,uniformthermalandweather-resistantboundarybetweenconditionedandunconditionedspacetoprescribedR-valueofanadjoininginsulatedassembly
Specification(s):Conductpre-inspectioninaccordancewithSWS2.0100.4WorkerSafety
Gaps,cracks,andholesinfireseparationslocatedwithintheworkareawillbevisuallyidentifiedandincorporatedintoairsealingworkscope,includingthosethatspantwoconditionedorunconditionedspaces
Wheredrawingsareavailablethatidentifyspecificfire-resistanceratings(i.e.,1hour,2hour),materialsandmethodswillbeemployedtopreserveorrestoresuchrating
Wheredrawingsareunavailableordonotidentifyspecificfire-resistanceratings,thefire-resistanceratingoftheassemblymaybeinferredfromthecurrentconstruction(i.e.,single5/8sheetrock,concretemasonryunit),andmaterialsandmethodsemployedwillbeconsistentwithrestoringorpreservingsuchinferredfire-resistancerating
Repairsnecessarytostabilizeworkareasandprotectorpreservetheintegrityofenergyimprovementwillbecompletedbeforeworkbegins
Insulationwillnotbeinstalledifmoisture-relatedissuesarenotresolved
Existingwatercontrolmeasureswillbeidentified
Airsealinglocationsontheexteriorwallswillbeidentified
Airsealingwillbecompletedbeforeinstallinginsulation
Objective(s):Identifyandremediatepest,moisture,airleakage,andelectricalproblemsbeforeinsulationinstallation
Ensureadurable,continuousthermalboundary
Avoidcompromisingexistingwatercontrolsystem
Insulation>Walls>EnclosedWalls4.1103.4d-Wallaccess
4.1103.4d-WallaccessDesiredOutcome:Maintainaconsistent,uniformthermalandweather-resistantboundarybetweenconditionedandunconditionedspacetoprescribedR-valueofanadjoininginsulatedassembly
Specification(s):Whenfeasible,insulationwillbeinstalledintocavitiesfromtheexteriorsideofthewall
Whenfeasible,exteriorcladdingattheinsulationaccesspointwillberemovedbeforecreatinganaccessholethroughthesheathing
Insulationaccesspointwillbecreatedtominimizeairbarrieranddrainageplanedisruption
Accesspointwillbesealedtobeairtightandwatertightafterinsulationinstallationbeforereinstallingtheexteriorcladding
Watermanagementsystemwillberepairedtofunctionasoriginallyintended(e.g.,lappingnewfeltpaperunderneaththeupperandoverthelowerjointoftheexistingfeltpaper)
Objective(s):Ensureoccupanthealthandsafety
Minimizedisruptionwithintheunits
Avoidcompromisingexistingwatercontrolsystem
Minimizeairandmoistureflowthroughthewallsystem
Insulation>Walls>EnclosedWalls4.1103.4e-Sealantselection
4.1103.4e-SealantselectionDesiredOutcome:Maintainaconsistent,uniformthermalandweather-resistantboundarybetweenconditionedandunconditionedspacetoprescribedR-valueofanadjoininginsulatedassembly
Specification(s):Sealantswillbecompatiblewiththeirintendedsurfacesandappliedinaccordancewithmanufacturerspecifications
Selectionwillbedurable,pestresistant,andhaveaweather-appropriateseal
Indoorsealantswillbelowvolatileorganiccompound(VOC)productsthatmeetindependenttestingandverificationprotocols,suchasGreenSealGS-36,"GREENGUARDChildrenandSchools,"orcomparablecertifications
Fire-resistance-ratedassemblieswillbeprovidedwithsealantspermittedbytheauthorityhavingjurisdictionandadoptedbuildingcode
Objective(s):Preventintrusionofmoistureandpestsintothesealedassembly
PreventexposingworkersoroccupantstoexcessiveVOClevels
Ensuresealantmeetsorexceedstheperformancecharacteristicsoftheassemblyandiscompliantwithlocalfirecoderequirements
Insulation>Walls>EnclosedWalls4.1103.4f-Exteriordensepack
4.1103.4f-ExteriordensepackDesiredOutcome:Maintainaconsistent,uniformthermalandweather-resistantboundarybetweenconditionedandunconditionedspacetoprescribedR-valueofanadjoininginsulatedassembly
Specification(s):Usingfilltube,100%ofeachcavitywillbecompletelyfilledtoaconsistentdensity:
Celluloseinsulationusedinanenclosedcavitywillbeinstalledat3.5poundspercubicfootorgreaterdensityBlownfiberglass,mineralfiber,rockandslagwool,orsprayfoamusedinanenclosedcavitywillbeinstalledinaccordanceatorabovemanufacturerrecommendeddensitytolimitairflowthatcorrespondstoanairpermeancevalueof3.5cubicfeetperminute/squarefeetat50pascals,asmeasuredusingthefollowingapplicablemethods:ASTMC522,orASTME283,orASTME2178AllinsulationmaterialsusedwillmeetASTME84flamespread/smokedevelopmentratingof25/50Thenumberofbagsinstalledwillbeconfirmedandwillmatchthenumberrequiredonthecoveragechart
Insulationwillbeverifiedtopreventvisibleairmovementat50pascalsofpressuredifferenceusingchemicalsmokeorotherapprovedverificationmethodbytheauthorityhavingjurisdiction
Objective(s):Eliminatevoidsandsettling
Minimizeframingcavityairflow
NewMexicoWAPvariancestates:Infraredthermographyorotherapprovedmethodmaybeusedinplaceofchemicalsmoketoverifyairsealing.NMWAPstandardsshallsupercedelocaljurisdictionalauthorityforapprovalofairsealingverificationmethods.
Insulation>Walls>EnclosedWalls4.1103.4g-Onsitedocumentation
4.1103.4g-OnsitedocumentationDesiredOutcome:Maintainaconsistent,uniformthermalandweather-resistantboundarybetweenconditionedandunconditionedspacetoprescribedR-valueofanadjoininginsulatedassembly
Specification(s):Adatedreceiptsignedbytheinstallerwillbeprovidedthatincludes:
CoverageareaThicknessR-value
Objective(s):Documentjobcompletiontocontractspecifications
Confirmamountofinsulationinstalled
Complywith16CFR460.17
Insulation>Floors>AccessibleFloors
4.1301.10-Above-GradeExposedFloor,JoistedAssembliesDesiredOutcome:Maintainaconsistent,protected,uniformthermalboundarybetweenconditionedandunconditionedspacetoprescribedR-value
Insulation>Floors>AccessibleFloors4.1301.10a-Pre-inspection
4.1301.10a-Pre-inspectionDesiredOutcome:Maintainaconsistent,protected,uniformthermalboundarybetweenconditionedandunconditionedspacetoprescribedR-value
Specification(s):Conductpre-inspectioninaccordancewithSWS2.0100.4WorkAreaInspectionandStabilization
Gaps,cracks,andholesinfireseparationslocatedwithintheworkareawillbevisuallyidentifiedandincorporatedintoairsealingworkscope,includingthosethatspantwoconditionedorunconditionedspaces
Wheredrawingsareavailablethatidentifyspecificfire-resistanceratings(i.e.,1hour,2hour),materialsandmethodswillbeemployedtopreserveorrestoresuchrating
Wheredrawingsareunavailableordonotidentifyspecificfire-resistanceratings,thefire-resistanceratingoftheassemblymaybeinferredfromthecurrentconstruction(i.e.,single5/8sheetrock,concretemasonryunit),andmaterialsandmethodsemployedwillbeconsistentwithrestoringorpreservingsuchinferredfire-resistancerating
Repairsnecessarytostabilizeworkareasandprotectorpreserveintegrityofenergyimprovementwillbecompletedbeforesubjectworkbegins
Objective(s):Repairmoisture-relatedissues
Provideasafeandstableworkenvironment
Insulation>Floors>AccessibleFloors4.1301.10b-Preparation
4.1301.10b-PreparationDesiredOutcome:Maintainaconsistent,protected,uniformthermalboundarybetweenconditionedandunconditionedspacetoprescribedR-value
Specification(s):Healthandsafetyconcernswillbeaddressedforoccupants,workers,andrepairmaterialsinaccordancewithOSHAstandards(OSHA1926,1910)
Prepareandisolatetheareainaccordancewithhealthandsafetystandardsfortheapplicationandmaterials(e.g.,extremetemperatures,lead,asbestos,carbonmonoxide)
Worklighting,workplatform,andadequateventilationwillbeprovided
Objective(s):Provideasafeworkingenvironment
Provideasafeindoorenvironmentalqualityworkingenvironment
Provideeffectiverepairaccess
Insulation>Floors>AccessibleFloors4.1301.10c-Subfloorpreparation
4.1301.10c-SubfloorpreparationDesiredOutcome:Maintainaconsistent,protected,uniformthermalboundarybetweenconditionedandunconditionedspacetoprescribedR-value
Specification(s):Sealingbetweenconditionedspaceandunconditionedspacewillbecompletedbeforeinsulating
Objective(s):Ensureairtightenvelope
Preventleakage
Insulation>Floors>AccessibleFloors4.1301.10d-Installation
4.1301.10d-InstallationDesiredOutcome:Maintainaconsistent,protected,uniformthermalboundarybetweenconditionedandunconditionedspacetoprescribedR-value
Specification(s):InsulationwillbeinstalledtoatleastprescribedR-value
Insulationwillbeinstalledincontactwithsubfloorwithoutgaps,voids,compressions,misalignments,orwindintrusions
Ifvaporretardersareused,theywillbeinstalledconsistentwithlocalclimate/coderequirements
Objective(s):Preventpotentialfirechases
ProvideeffectiveR-value
Preventexcessivevapormigrationintothefloorassemblyand/orconditionedspace
Insulation>Floors>AccessibleFloors4.1301.10e-Installationofbattsordensepack
4.1301.10e-InstallationofbattsordensepackDesiredOutcome:Maintainaconsistent,protected,uniformthermalboundarybetweenconditionedandunconditionedspacetoprescribedR-value
Specification(s):Insulationwillcompletelyfillthecavityspacewithinthejoistsortrusses
Objective(s):
Minimizesagging,gaps,andvoids
Insulation>Floors>AccessibleFloors4.1301.10f-Installationofrigidinsulation
4.1301.10f-InstallationofrigidinsulationDesiredOutcome:Maintainaconsistent,protected,uniformthermalboundarybetweenconditionedandunconditionedspacetoprescribedR-value
Specification(s):Rigidinsulationwillbemechanicallyfastenedtothebottomofthesubfloororatthebottomofthejoistsortrusses
Ifattachedatthebottomofthejoistsortrusses,rigidinsulationwillbeattachedattheexteriorperimeter/band
Insulationwillbeinstalledeitherasin-filloratthebottomofthejoists.Whererigidinsulationisinstalledbetweenjoists,theperimeterofeachjoistbaywillbeairsealedwithappropriatesealantstopreventairbypassesaroundrigidinsulationmaterials
Rigidfoamplasticsusedasinsulationwillincorporateathermalandignitionbarrier,asrequiredbythebuildingcode
Acontinuousairbarrierwillbeinstalledbelowtheinsulationandtotheexterior
Objective(s):Minimizeconvectiveloops
Preventfreezingofplumbingpipes
Ensureairbarrierisalignedwiththeinsulation
Insulation>Floors>AccessibleFloors4.130.10g-Installationofspraypolyurethanefoam(SPF)
4.130.10g-Installationofspraypolyurethanefoam(SPF)DesiredOutcome:Maintainaconsistent,protected,uniformthermalboundarybetweenconditionedandunconditionedspacetoprescribedR-value
Specification(s):SPFwillbeappliedtobottomsideofsubfloorbetweenfloorjoistsandallrim/bandjoists
Sprayappliedfoamproductswillincorporateathermalandignitionbarrierasrequiredbythebuildingcode
Insulationwillbeinstalledbyfoaminstallers
Objective(s):Minimizeconvectiveloops
Insulation>Floors>AccessibleFloors4.1301.10h-Installation,ifmechanicalsinjoistedassemblies(appliestoallinsulationtypes)
4.1301.10h-Installation,ifmechanicalsinjoistedassemblies(appliestoallinsulationtypes)
DesiredOutcome:Maintainaconsistent,protected,uniformthermalboundarybetweenconditionedandunconditionedspacetoprescribedR-value
Specification(s):Allplumbingormechanicalductworkwillbeenclosedwithintheinsulatedspaceandwillhavesufficientinsulationontheexteriorside
Objective(s):Preventfreezingofplumbingpipes
Insulation>Floors>AccessibleFloors4.1301.10i-Securebatts
4.1301.10i-SecurebattsDesiredOutcome:Maintainaconsistent,protected,uniformthermalboundarybetweenconditionedandunconditionedspacetoprescribedR-value
Specification(s):Battswillbesecuredwithphysicalfasteners
Objective(s):Ensureinsulationremainsincontactwithsubfloor
Insulation>Floors>AccessibleFloors4.1301.10j-Rigidprotectivebarrier
4.1301.10j-RigidprotectivebarrierDesiredOutcome:Maintainaconsistent,protected,uniformthermalboundarybetweenconditionedandunconditionedspacetoprescribedR-value
Specification(s):Acontinuousrigidbarrier,suitabletowithstandweather,moisture,andpestcontact,andwithafire-resistanceratingequaltotheresistanceratingoftheoriginalfloorassemblywillbemechanicallyfastenedtoundersideoffloorassembly
Objective(s):Protectinsulation
Insulation>Floors>AccessibleFloors4.1301.10k-Propertymanagereducation
4.1301.10k-PropertymanagereducationDesiredOutcome:Maintainaconsistent,protected,uniformthermalboundarybetweenconditionedandunconditionedspacetoprescribedR-value
Specification(s):Adatedreceiptsignedbytheinstallerwillbeprovidedthatincludes:
InsulationtypeCoverageareaR-valueInstalledthicknessandsettledthickness(settledthicknessrequiredforloose-fillonly)Numberofbagsinstalledinaccordancewithmanufacturerspecifications(forloose-fillonly)
Objective(s):Documentjobcompletiontocontractspecifications
Confirmamountofinsulationinstalled
Complywith16CFR460.17
Insulation>Ducts>InsulatingDucts
4.1601.6-InsulatingMetalDucts—LowRiseDesiredOutcome:Loweredthermalconductanceofductsystemandminimizedcondensationontheductsystem
Note:
Insulation>Ducts>InsulatingDucts4.1601.6a-Selectionofductinsulationmaterial
4.1601.6a-SelectionofductinsulationmaterialDesiredOutcome:Loweredthermalconductanceofductsystemandminimizedcondensationontheductsystem
Specification(s):DuctinsulationwillbeaminimumofR-8,inaccordancewithlocalcode,orburiedunderatticinsulation,whicheverisgreater,andhaveanattachedvaporbarrier
Ductswillnotbeburiedinhothumidandwarmcoastalregions
Objective(s):Decreaseheatlossandcondensationproblems
Insulation>Ducts>InsulatingDucts4.1601.6b-Ductsealing
4.1601.6b-DuctsealingDesiredOutcome:Loweredthermalconductanceofductsystemandminimizedcondensationontheductsystem
Specification(s):Beforeinsulationisapplied,allaccessibleductswillbesealedwithaUL-approvedmasticinconformancewiththeapplicablecodeadoptedbythejurisdiction
Objective(s):Minimizeductleakage
Insulation>Ducts>InsulatingDucts4.1601.6c-Attachmentofductinsulation
4.1601.6c-AttachmentofductinsulationDesiredOutcome:Loweredthermalconductanceofductsystemandminimizedcondensationontheductsystem
Specification(s):Ductinsulationwillbesecuredtotheductsystemusinganappropriatematerialperapplicablestandardsthatwillsecurelyholdtheinsulationtotheductwork,withoutcompressingtheinsulationintheprocess
Objective(s):Ensureasecureconnectionbetweentheductsystemandtheductinsulation
Insulation>Ducts>InsulatingDucts4.1601.6d-Sealingoftheductinsulation
4.1601.6d-SealingoftheductinsulationDesiredOutcome:Loweredthermalconductanceofductsystemandminimizedcondensationontheductsystem
Specification(s):Usingatapeormasticapprovedbythemanufacturer,allseamsandconnectionoftheductinsulationwillbesealed
Nogapswillexistbetweenpiecesofductinsulation
Objective(s):Preventgapsinthevaporbarrieroftheinsulation
HeatingandCooling>ForcedAir>Design
5.3001.4-EquipmentSelection—LowRiseDesiredOutcome:Equipmentsizedproperlyandoperatingefficiently
HeatingandCooling>ForcedAir>Design5.3001.4a-Loadcalculation:heatlossorgain
5.3001.4a-Loadcalculation:heatlossorgainDesiredOutcome:Equipmentsizedproperlyandoperatingefficiently
Specification(s):Heatlossorgainofthebuildingwillbecalculatedconsideringthefollowing:
R-valuesofbuildingcomponentsU-valueandsolarheatgaincoefficientofglazingOrientationandexteriorshadingofglazingDuctheatlossorgainInfiltrationtargetorfinalinfiltrationafterairsealingiscompletedVentilationInternalgains
ANSI/ACCAManualJResidentialLoadCalculation,8thed.,andANSI/ACCA5QIHVACQualityInstallationSpecificationrequirementsorASHRAEequivalentswillbeusedforallresidentialloadcalculations
ANSI/ACCAManualNCommercialLoadCalculationorASHRAEequivalentswillbeusedforallcommercialloadcalculations
Room-by-roomcalculationswillbeperformedwheninstallingnewductsystemsorinretro-commissionprojects
Objective(s):Accuratelycalculatesensibleandlatentloadforthetotalbuildingandeachroom
Properlysizeequipmentfortheload
HeatingandCooling>ForcedAir>Design5.3001.4b-Loadcalculation:designconditionsofsinglestageorsinglespeedequipment
5.3001.4b-Loadcalculation:designconditionsofsinglestageorsinglespeedequipmentDesiredOutcome:Equipmentsizedproperlyandoperatingefficiently
Specification(s):Interiordesigntemperatureswillbeselectedbasedon75°forcoolingand70°forheating,unlessotherwisestatedbylocalcode
EnsurethedesignloadsreflectpeaksensibleandpeaklatentloadconditionsperASHRAEHandbook—Fundamentals
Designsensibleloads,whichwilldominateindryclimates,shouldbebaseduponoutdoordesigncoolingconditionsforthelocation(e.g.,peakcoolingdrybulbtemperatureintheASHRAEHandbook—Fundamentals)
Designlatentloads,whicharemostimportantinmoistorhumidclimates,shouldbebasedupondesigndehumidificationconditionsforthelocation(e.g.,designdewpointtemperatureandmeancoincidentdrybulb
temperatureintheASHRAEHandbook—Fundamentals)
Objective(s):Accuratelycalculatesensibleandlatentloadforthebuilding
Properlysizeequipmentfortheload
HeatingandCooling>ForcedAir>Design5.3001.4c-Loadcalculation:designconditionsformultistage,variablespeedequipment
5.3001.4c-Loadcalculation:designconditionsformultistage,variablespeedequipmentDesiredOutcome:Equipmentsizedproperlyandoperatingefficiently
Specification(s):Interiordesigntemperatureswillbeselectedbasedon75°forcoolingand70°forheating,unlessotherwisestatedbylocalcode
EnsurethedesignloadsreflectpeaksensibleandpeaklatentloadconditionsperASHRAEHandbook—Fundamentals
Designsensibleloads,whichwilldominateindryclimates,shouldbebaseduponoutdoordesigncoolingconditionsforthelocation(e.g.,peakcoolingdrybulbtemperatureintheASHRAEHandbook—Fundamentals)
Designlatentloads,whicharemostimportantinmoistorhumidclimates,shouldbebasedupondesigndehumidificationconditionsforthelocation(e.g.,designdewpointtemperatureandmeancoincidentdrybulbtemperatureintheASHRAEHandbook—Fundamentals)
Objective(s):Accuratelycalculatesensibleandlatentloadforthebuilding
Properlysizeequipmentfortheload
HeatingandCooling>ForcedAir>Design5.3001.4d-Equipmentselection:airconditioningandheatpumps
5.3001.4d-Equipmentselection:airconditioningandheatpumpsDesiredOutcome:Equipmentsizedproperlyandoperatingefficiently
Specification(s):Equipmentcapableofmeetingthesensibleandlatentloadofthebuildingwillbeselectedusingthedetailedcapacitytablesprovidedbythemanufacturer
Equipmentwillnotbesizedbymorethan115%oftotalloadornextavailablesize
ANSI/ACCAManualSResidentialEquipmentSelection,andANSI/ACCA5QIHVACQualityInstallationSpecificationrequirementsorASHRAEequivalentswillbeusedforallresidentialequipmentselection
ANSI/ACCAManualCSCommercialApplicationsSystemsandEquipmentorASHRAEequivalentswillbeusedforallcommercialequipmentselection
Objective(s):Ensuretheequipmentisabletoheat,cool,anddehumidifythebuilding
HeatingandCooling>ForcedAir>Design5.3001.4e-Equipmentselection:auxiliaryheatforheatpumps
5.3001.4e-Equipmentselection:auxiliaryheatforheatpumpsDesiredOutcome:Equipmentsizedproperlyandoperatingefficiently
Specification(s):Usethelowestcapacityheatingequipmentrequiredtoheatthebuilding,utilizingthedetailedcapacitytablesprovidedbytheequipmentmanufacturer
Equipmentwillbeselectedtoprovideachangeoverpoint,calculatedusinginformationfromthedetailedcapacitytablesprovidedbytheequipmentmanufacturer,weatherdata,andutilitycost
Objective(s):Maximizetheheatingpotentialofthecompressor
Minimizetheuseofauxiliaryheat
HeatingandCooling>ForcedAir>Design5.3001.4f-Equipmentselection:furnaces
5.3001.4f-Equipmentselection:furnacesDesiredOutcome:Equipmentsizedproperlyandoperatingefficiently
Specification(s):Thesmallestcapacityheatingequipmentwillbeselectedthatiscapableofmeetingthedesignheatingloadandprovidingtheairmovementrequiredbytheairconditioning
Whenanair-conditioningsystemisnotdesignedwiththefurnace,thesmallestcapacityheatingequipmentwillbeselectedthatiscapableofmeetingtheheatingload
Thelowestcapacitycoolingequipmentrequiredtocoolthebuildingwillbeused
Equipmentwillnotbesizedbymorethan115%oftotalloadornextavailablesize
Objective(s):Ensureequipmentmeetstheheatingloadofthebuilding
Ensureequipmentmovesrequiredairforairconditioning,ifapplicable
HeatingandCooling>ForcedAir>Design
5.3001.5-DuctworkandTerminationDesign—LowRiseDesiredOutcome:Efficientairflowtoallroomsisensuredbyproperductwork
Note:
HeatingandCooling>ForcedAir>Design5.3001.5a-Sizing
5.3001.5a-SizingDesiredOutcome:Efficientairflowtoallroomsisensuredbyproperductwork
Specification(s):Ductswillbesizedtodelivertheappropriateamountofairflow(bothsupplyandreturn)neededtosatisfytheheatingand/orcoolingloadofthebuilding
Ductswillbesizedusingfrictioncharts
ANSI/ACCAManualDResidentialDuctSystemsorASHRAEequivalentswillbeusedforallresidentialductworksizing
ANSI/ACCAManualQLowPressure,LowVelocityDuctSystemDesignorASHRAEequivalentswillbeusedforallcommercialductworksizing
Objective(s):Minimizestaticpressure
Maximizeairflow
HeatingandCooling>ForcedAir>Design5.3001.5b-Airhandlertoreturnplenum
5.3001.5b-AirhandlertoreturnplenumDesiredOutcome:Efficientairflowtoallroomsisensuredbyproperductwork
Specification(s):ReturnplenumwillbedesignedinaccordancewithANSI/ACCAManualDorequivalent
Radiuselbowfittingsorsquarefittingswithturningvaneswillbeusedtodirectreturnairwhena90°turnisrequired
Objective(s):Minimizestaticpressure
Maximizeairflow
HeatingandCooling>ForcedAir>Design5.3001.5c-Airhandlertosupplyplenum
5.3001.5c-Airhandlertosupplyplenum
DesiredOutcome:Efficientairflowtoallroomsisensuredbyproperductwork
Specification(s):SupplyplenumwillbedesignedinaccordancewithANSI/ACCAManualDorequivalent
Radiuselbowfittingsorsquarefittingswithturningvaneswillbeinstalledtodirectsupplyair
Supplyplenumwillbethesamesizeastheairhandlersupplyopening
Objective(s):Minimizestaticpressure
Maximizeairflow
HeatingandCooling>ForcedAir>Design5.3001.5d-Buildingcavitiesusedasductwork
5.3001.5d-BuildingcavitiesusedasductworkDesiredOutcome:Efficientairflowtoallroomsisensuredbyproperductwork
Specification(s):Buildingcavitieswillnotbeusedasductworkinnewsystems
Inexistingsystems,buildingcavitieswillbesealedandtested
Objective(s):Maximizeairflow
Minimizeenergyuse
Safeguardindoorairquality
HeatingandCooling>ForcedAir>Design5.3001.5e-Reducers
5.3001.5e-ReducersDesiredOutcome:Efficientairflowtoallroomsisensuredbyproperductwork
Specification(s):Reducersbetweensectionsofdifferentsizeductswillbeinaccordancewithexistingstandardsbasedonductmaterial(SMACNA,NAIMA)
Objective(s):Minimizestaticpressure
Maximizeairflow
HeatingandCooling>ForcedAir>Design5.3001.5f-Supplybranchrunouts
5.3001.5f-Supplybranchrunouts
DesiredOutcome:Efficientairflowtoallroomsisensuredbyproperductwork
Specification(s):Runswillbeinstalledasshortaspossible
Objective(s):Minimizestaticpressure
Maximizeairflow
HeatingandCooling>ForcedAir>Design5.3001.5g-Boots
5.3001.5g-BootsDesiredOutcome:Efficientairflowtoallroomsisensuredbyproperductwork
Specification(s):Ifusingflexibleductwithstraightboots,ductwillbeconnectedtobootwithnobend
Arigidelbowwillbeusedwhenaflexibleductchangesdirection
Arigidconnectorwillbeusedwhenjoiningtwopiecesofflexibleducttogether
Objective(s):Minimizestaticpressure
Maximizeairflow
HeatingandCooling>ForcedAir>Design5.3001.5h-Supplyterminations
5.3001.5h-SupplyterminationsDesiredOutcome:Efficientairflowtoallroomsisensuredbyproperductwork
Specification(s):TerminationswillbeselectedbasedonACCAManualTAirDistributionBasics
Objective(s):Minimizestaticpressure
Maximizeairflow
HeatingandCooling>ForcedAir>Design5.3001.5i-Returngrillesizing
5.3001.5i-ReturngrillesizingDesiredOutcome:Efficientairflowtoallroomsisensuredbyproperductwork
Specification(s):
TerminationswillbeselectedbasedonACCAManualTAirDistributionBasics
Grillegrossareawillbeequaltoorlargerthanreturnbox
Objective(s):Minimizestaticpressure
Maximizeairflow
HeatingandCooling>ForcedAir>Design5.3001.5j-Manualvolumedampers
5.3001.5j-ManualvolumedampersDesiredOutcome:Efficientairflowtoallroomsisensuredbyproperductwork
Specification(s):Damperswillbeinstalledasclosetothetrunkaspossiblewhilestillbeingaccessibletoallowforadjustmentafterinteriorfinishesareinstalled
Objective(s):Minimizestaticpressureandnoise
Maximizeairflow
HeatingandCooling>ForcedAir>Design5.3001.5k-Flexibleducts
5.3001.5k-FlexibleductsDesiredOutcome:Efficientairflowtoallroomsisensuredbyproperductwork
Specification(s):Flexibleductswillnotbebentmorethan45°withoutrigidelbow
Objective(s):Minimizestaticpressure
Maximizeairflow
HeatingandCooling>ForcedAir>Design5.3001.5l-Take-offs
5.3001.5l-Take-offsDesiredOutcome:Efficientairflowtoallroomsisensuredbyproperductwork
Specification(s):Take-offsthatcreatehighturbulencewillnotbeused(e.g.,elbowswithintegrateddampers,scoops)
Take-offswillbeinstalledontothetrunkinaccordancewithductconstructionstandards(SMACNA)
Objective(s):
Minimizestaticpressure
Maximizeairflow
HeatingandCooling>ForcedAir>Design5.3001.5m-Firedampers
5.3001.5m-FiredampersDesiredOutcome:Efficientairflowtoallroomsisensuredbyproperductwork
Specification(s):Firedampersshallbeinstalledasrequiredbyapplicablefirecode
Objective(s):Minimizestaticpressure
Maximizeairflow
HeatingandCooling>ForcedAir>SitePreparation
5.3002.2-SequenceofOperation—LowRiseDesiredOutcome:Sequenceofoperationofthesystemverified
Note:
HeatingandCooling>ForcedAir>SitePreparation5.3002.2a-Verification
5.3002.2a-VerificationDesiredOutcome:Sequenceofoperationofthesystemverified
Specification(s):Thesequenceofoperationofthesystemwillbeverifiedinaccordancewiththemanufacturer'sinstallation,operation,andmaintenancemanuals
Objective(s):Ensuresystemcomponentsfunctionandoperateinthecorrectsequence
HeatingandCooling>ForcedAir>SitePreparation
5.3002.4-PreparationforNewEquipment—LowRiseDesiredOutcome:Existingequipmentremovedsafelyandinaccordancewithlocalordinances
Note:Theauthorityhavingjurisdictionmayrequirethatalicensedprofessionalperformcertaintasksoutlinedinthisdetail.
HeatingandCooling>ForcedAir>SitePreparation5.3002.4a-Access
5.3002.4a-AccessDesiredOutcome:Existingequipmentremovedsafelyandinaccordancewithlocalordinances
Specification(s):Acode-compliantwalkwayandserviceplatformwillbeinstalledinatticsasapplicable,ifnotpresent
Walkwayandplatformwillbeabovethelevelofinsulation
Objective(s):Ensurenewequipmentcanbeinstalledandserviced
Maintainadequateinsulationlevel
HeatingandCooling>ForcedAir>SitePreparation5.3002.4b-Environmentalhazards
5.3002.4b-EnvironmentalhazardsDesiredOutcome:Existingequipmentremovedsafelyandinaccordancewithlocalordinances
Specification(s):Ifsuspectedmoldisfound,determinethesourceandcause,repairissuesandremovethesuspectedmold
Ifafriableasbestos-likesubstanceisfoundtobepresentinanareathatwillbedisturbedbywork,itmustbetestedbyacertifiedorganization,andallsystemcomponentsandpossibledisturbedsurroundingareaswillbecertifiedfreeofasbestosbyalicensedprofessionalbeforeequipmentremovalcanbegin
Objective(s):Protectworkersandoccupantsfrominjury
Remediatehealthhazardsusingcertifiedcontractors
HeatingandCooling>ForcedAir>SitePreparation5.3002.4c-Disconnectionofutilities
5.3002.4c-DisconnectionofutilitiesDesiredOutcome:Existingequipmentremovedsafelyandinaccordancewithlocalordinances
Specification(s):
Electricityandfuelwillbeturnedoff
Objective(s):Protectworkersandoccupantsfrominjury
HeatingandCooling>ForcedAir>SitePreparation5.3002.4d-Refrigerantrecovery
5.3002.4d-RefrigerantrecoveryDesiredOutcome:Existingequipmentremovedsafelyandinaccordancewithlocalordinances
Specification(s):Refrigerantwillberecoveredinaccordancewith40CFR608(EPA)
Allworkwillbedonebyalicensedprofessionalorqualifiedperson
Objective(s):Limitthereleaseofozone-depletingsubstances
Protectworkersandoccupantsfrominjury
HeatingandCooling>ForcedAir>SitePreparation5.3002.4e-Disconnectionofequipment
5.3002.4e-DisconnectionofequipmentDesiredOutcome:Existingequipmentremovedsafelyandinaccordancewithlocalordinances
Specification(s):Refrigerantlines,plumbing,ducts,electric,controlwires,vents,andfuelsupplywillbedisconnected
Allworkwillbedonebyalicensedprofessionalorqualifiedperson
Objective(s):Ensureequipmentcanberemoved
HeatingandCooling>ForcedAir>SitePreparation5.3002.4f-Removal
5.3002.4f-RemovalDesiredOutcome:Existingequipmentremovedsafelyandinaccordancewithlocalordinances
Specification(s):Equipmentwillberemoved(e.g.,furnace,airhandler,evaporator,condensingunit)
Equipmentwillberemovedfromthespacewithoutdamagingpropertyanddisturbingorcompressingtheinsulation
Equipmentwillbedisposedofinaccordancewithlocalordinancesandregulations
Objective(s):Provideroomtoinstallnewequipmentandworksafely
Complywithdisposallawsinaccordancewithlocalordinances
HeatingandCooling>ForcedAir>SitePreparation
5.3002.7-SettingofAirHandler—LowRiseDesiredOutcome:Airhandlersetproperlyinanappropriateplace
Note:Theauthorityhavingjurisdictionmayrequirethatalicensedprofessionalperformcertaintasksoutlinedinthisdetail.
HeatingandCooling>ForcedAir>SitePreparation5.3002.7a-Location
5.3002.7a-LocationDesiredOutcome:Airhandlersetproperlyinanappropriateplace
Specification(s):Equipmentwillbeinstalledinadrylocationwithintheconditionedspacewhenfeasible
Equipmentwillbeproperlyisolatedfrompollutantsources(e.g.,garages)
Equipmentwillbeinstalledinamannertoprovideeaseofaccessforroutinemaintenance/service
Allworkwillbedonebyalicensedprofessionalorqualifiedperson
Objective(s):Preventrustandcorrosion
Protectequipmentfrombulkwaterandmoisture
Preventexposuretogarageairpollutants
Ensurethatequipmentismaintained/serviced
HeatingandCooling>ForcedAir>SitePreparation5.3002.7b-Clearance
5.3002.7b-ClearanceDesiredOutcome:Airhandlersetproperlyinanappropriateplace
Specification(s):Equipmentwillbeinstalledwithproperclearancesinaccordancewithlocalcodesandmanufacturerspecifications
Alternativelocationswillbeconsideredforequipmentwhenexistinglocationsarenotsuitable
Objective(s):Ensureequipmenthasproperclearancesforfireriskandaccessibility
Ensureequipmentoperatesasdesigned
HeatingandCooling>ForcedAir>SitePreparation5.3002.7c-Connections
5.3002.7c-Connections
DesiredOutcome:Airhandlersetproperlyinanappropriateplace
Specification(s):Equipmentwillbeinstalledsoconnectionsallowproperoperationoftheequipmentandaccessibility(e.g.,electricalservice,condensationdrains,ductwork,fuel,venting,refrigerantlines)
Equipmentwillbeinstalledsothedrainpanoperatesproperly
Objective(s):Ensureconnectionsdonotinterferewiththeoperationandserviceoftheequipment
HeatingandCooling>ForcedAir>SitePreparation5.3002.7d-Support:horizontalairflow,attic
5.3002.7d-Support:horizontalairflow,atticDesiredOutcome:Airhandlersetproperlyinanappropriateplace
Specification(s):Equipmentwillbesupportedwithanonwickingfireproofplatformorsuspendedwithathreadedrodinaccordancewithlocalcodesandmanufacturerspecifications
Equipmentwillbeplacedonvibrationpads
Objective(s):Ensureequipmentisstable,level,anddoesnottransmitvibration
Avoidcompressingordisturbingatticinsulation
HeatingandCooling>ForcedAir>SitePreparation5.3002.7e-Support:horizontalairflow,basement,orcrawlspace
5.3002.7e-Support:horizontalairflow,basement,orcrawlspaceDesiredOutcome:Airhandlersetproperlyinanappropriateplace
Specification(s):Equipmentwillbesupportedwithanonwicking,fireproofmaterialorsuspendedwithathreadedrodinaccordancewithlocalcodesandmanufacturerspecifications
Equipmentwillbeplacedonvibrationpads
Objective(s):Ensureequipmentisstable,level,anddoesnottransmitvibration
Avoidcompressingordisturbinginsulation
HeatingandCooling>ForcedAir>SitePreparation5.3002.7f-Support:upflowonaplatform
5.3002.7f-Support:upflowonaplatformDesiredOutcome:
Airhandlersetproperlyinanappropriateplace
Specification(s):Equipmentwillbesupportedonnonflammablematerialcapableofsupportingtheweightoftheequipment
Airhandleropeningwillbefreeofobstructions
Equipmentwillbeplacedonvibrationpads
Objective(s):Properlysupporttheequipment
Preventafirehazard
Ensureplatformdoesnotimpedeairflow
HeatingandCooling>ForcedAir>SitePreparation5.3002.7g-Support:downflow
5.3002.7g-Support:downflowDesiredOutcome:Airhandlersetproperlyinanappropriateplace
Specification(s):Equipmentwillbesupportedonductworkcapableofsupportingtheweightoftheequipment
Equipmentwillbesupportedonductworkwithrigidexteriorinsulationfastenedtotheductwork
Objective(s):Properlysupportequipment
Protectequipmentfrommoisturedamage
Reduceheatloss
HeatingandCooling>ForcedAir>SitePreparation5.3002.7h-Sealing
5.3002.7h-SealingDesiredOutcome:Airhandlersetproperlyinanappropriateplace
Specification(s):Gapslargerthan1/4"betweenairhandlerandadjoiningductworkorequipment(e.g.,evaporatorcoil,filterrack)willbebridgedwithsheetmetal,andsealedwithmasticandfiberglassmesh
Allairhandlerjointswillbesealedwithmasticandfiberglassmesh
Airhandlerjointsandnon-serviceopeningswillbesealedtoeliminateallgapswithNFPA90AandBapprovedsealant
Ifunitisinstalledinabuildingcavity,thecavitymustbesealedpriortotheinstallationtoeliminateanyreturnairleaksfromadjoiningchases
Objective(s):Ensureairhandlerdoesnotleakair
Ensurethesealingisdurable
Preventincreasedresistancetoairflow
HeatingandCooling>ForcedAir>SitePreparation5.3002.7i-Drainage
5.3002.7i-DrainageDesiredOutcome:Airhandlersetproperlyinanappropriateplace
Specification(s):Asecondarydrainpananddrainlinethatprovidesproperpitchandafloatswitchwillbeinstalledbeneathequipmentlocatedinareaswherewaterdamagemayoccur,suchasatticsandconditionedspaces
FloatswitchwillbeinterlockedwiththecoolingcircuittodisableACwhenleakoccurs
Objective(s):Preventwaterdamage
HeatingandCooling>ForcedAir>SystemAssessmentandMaintenance
5.3003.17-DataPlateVerification—LowRiseDesiredOutcome:Dataisrecordedforfutureserviceworkandcommissioning
Note:
HeatingandCooling>ForcedAir>SystemAssessmentandMaintenance5.3003.17a-Dataplateverification
5.3003.17a-DataplateverificationDesiredOutcome:Dataisrecordedforfutureserviceworkandcommissioning
Specification(s):Equipmentwillbevisuallyinspected
Informationwillberecordedfromtheindoorandoutdoorequipmentdataplates
Informationwillbeenteredintotheoperationsandmanagementmanual
Objective(s):Ensuretechnicianhasequipmentdatanecessaryforcommissioningandfutureservicework
HeatingandCooling>ForcedAir>SystemAssessmentandMaintenance
5.3003.18-LeakDetection—LowRiseDesiredOutcome:Dangerousleaksdetectedbeforecausinginjurytotheoccupantordamagetothebuilding
Note:
HeatingandCooling>ForcedAir>SystemAssessmentandMaintenance5.3003.18a-Carbonmonoxide(CO)detection
5.3003.18a-Carbonmonoxide(CO)detectionDesiredOutcome:Dangerousleaksdetectedbeforecausinginjurytotheoccupantordamagetothebuilding
Specification(s):PersonalCOalarmwillbeworninaccordancewithBuildingPerformanceInstitutestandards
Objective(s):ProtectworkersandoccupantsfrompossibleCOpoisoning
HeatingandCooling>ForcedAir>SystemAssessmentandMaintenance5.3003.18b-Gasleakdetection
5.3003.18b-GasleakdetectionDesiredOutcome:Dangerousleaksdetectedbeforecausinginjurytotheoccupantordamagetothebuilding
Specification(s):Gaspipeswillbetestedforleakswithanelectroniccombustiblegasleakdetectorandverifiedwithbubblesolution
Wheninstallingnewgaslinesacodeapprovedstandingpressuretestwillbeconductedtodetectleaks
Objective(s):Ensuregaslinesdonotleak
HeatingandCooling>ForcedAir>SystemAssessmentandMaintenance5.3003.18c-Fueloilleakdetection
5.3003.18c-FueloilleakdetectionDesiredOutcome:Dangerousleaksdetectedbeforecausinginjurytotheoccupantordamagetothebuilding
Specification(s):Oiltank,pipingandequipmentwillbevisuallyinspectedforoilleaks
Fueloiltankswillbeinspectedforleaksandcorrosion
Objective(s):Ensurefueloillinesandtanksdonotleak
HeatingandCooling>ForcedAir>SystemAssessmentandMaintenance
5.3003.19-RefrigerantLineInspection—LowRiseDesiredOutcome:Refrigerantlinesproperlyinstalled
Note:
HeatingandCooling>ForcedAir>SystemAssessmentandMaintenance5.3003.19a-Insulation
5.3003.19a-InsulationDesiredOutcome:Refrigerantlinesproperlyinstalled
Specification(s):Allrefrigerantlineswillbeinsulatedbasedontheequipmentmanufacturer'srequirementsinconformancewithapplicablecodeadoptedbythejurisdiction
Allinstalledinsulationwillbeproperlysealed
Objective(s):Ensurerefrigerantlinesdonotgainexcessiveheat
HeatingandCooling>ForcedAir>SystemAssessmentandMaintenance5.3003.19b-Ultraviolet(UV)protectionofinsulation
5.3003.19b-Ultraviolet(UV)protectionofinsulationDesiredOutcome:Refrigerantlinesproperlyinstalled
Specification(s):Ifexposedtosunlight,refrigerantlineinsulationwillbeprotectedfromUVdegradation
Objective(s):Installinsulationsoitdoesnotdegrade
HeatingandCooling>ForcedAir>SystemAssessmentandMaintenance5.3003.19c-Sizing
5.3003.19c-SizingDesiredOutcome:Refrigerantlinesproperlyinstalled
Specification(s):Refrigerantlineswillbesizedtomeetmanufacturerspecificationsfortheinstalledequipment
Objective(s):Ensuresystemmovestheappropriatevolumeofrefrigerant
HeatingandCooling>ForcedAir>SystemAssessmentandMaintenance5.3003.19d-Installationquality
5.3003.19d-InstallationqualityDesiredOutcome:Refrigerantlinesproperlyinstalled
Specification(s):Refrigerantlineswillbeinstalledwithoutkinks,crimps,orexcessivebends
Refrigerantlineswillbejoinedtogetherusingmanufacturer-approvedmethod(s)
Properfilterdryer(s)willbeinstalled
RefrigerantlineswillbecheckedforleaksfollowingEPASection608andverifiedleakfreebeforerefrigerantcharging
Properevacuationanddehydrationtechniqueswillbeemployedpriortorefrigerantcharging
Objective(s):Ensuresystemmovestheappropriatevolumeofrefrigerant
Ensurecontaminatestonotharmthesystem
Ensurethesystemisdurable
HeatingandCooling>ForcedAir>SystemAssessmentandMaintenance5.3003.19e-Support
5.3003.19e-SupportDesiredOutcome:Refrigerantlinesproperlyinstalled
Specification(s):Refrigerantlineswillberouted,supported,andsecuredtothebuildinginamannerthatprotectsthelinefromdamagebyworkersoroccupants
Objective(s):Ensurerefrigerantlinesdonotmove,vibrate,orsag
Protectlinesfromdamage
HeatingandCooling>ForcedAir>SystemAssessmentandMaintenance
5.3003.20-ElectricalService—LowRiseDesiredOutcome:Electricalcomponentsproperlytested
Note:
HeatingandCooling>ForcedAir>SystemAssessmentandMaintenance5.3003.20a-Polarity
5.3003.20a-PolarityDesiredOutcome:Electricalcomponentsproperlytested
Specification(s):Polarityoftheequipmentwillbecorrect
Objective(s):Ensureequipmentoperatesasdesigned
Ensureequipmentoperatessafely
HeatingandCooling>ForcedAir>SystemAssessmentandMaintenance5.3003.20b-Voltage:incomingpower
5.3003.20b-Voltage:incomingpowerDesiredOutcome:Electricalcomponentsproperlytested
Specification(s):Voltagewillbeinaccordancewithmanufacturerspecifications
Objective(s):Ensureequipmentoperatesasdesigned
HeatingandCooling>ForcedAir>SystemAssessmentandMaintenance5.3003.20c-Wiresize
5.3003.20c-WiresizeDesiredOutcome:Electricalcomponentsproperlytested
Specification(s):Wiresizeshouldbeappropriatefortheequipmentinstalled
Objective(s):Ensureequipmentoperatesasdesigned
Ensureequipmentoperatessafely
HeatingandCooling>ForcedAir>SystemAssessmentandMaintenance5.3003.20d-Servicedisconnect
5.3003.20d-ServicedisconnectDesiredOutcome:Electricalcomponentsproperlytested
Specification(s):Theproperservicedisconnectwillbeinstalled,andiffused,thecorrectfuseswillbeinstalled
Objective(s):Ensureequipmentoperatessafely
HeatingandCooling>ForcedAir>SystemAssessmentandMaintenance5.3003.20e-Voltage:contactor
5.3003.20e-Voltage:contactorDesiredOutcome:Electricalcomponentsproperlytested
Specification(s):Voltagedropwillbewithinacceptablerangeinaccordancewithmanufacturerspecifications
Objective(s):Ensurecontactordoesnotoverheat
Ensureequipmentoperatesasdesigned
HeatingandCooling>ForcedAir>SystemAssessmentandMaintenance5.3003.20f-Grounding
5.3003.20f-GroundingDesiredOutcome:Electricalcomponentsproperlytested
Specification(s):Adequategroundingwillbepresent
Objective(s):Ensureequipmentoperatesasdesigned
Ensureequipmentoperatessafely
HeatingandCooling>ForcedAir>SystemAssessmentandMaintenance5.3003.20g-Bloweramperage
5.3003.20g-BloweramperageDesiredOutcome:Electricalcomponentsproperlytested
Specification(s):Amperagewillbewithinoriginalequipmentmanufacturer(OEM)specificationsand/orcoderequirements
Objective(s):Ensureequipmentoperatesasdesigned
Ensureequipmentoperatesefficiently
Ensureequipmentoperatessafely
HeatingandCooling>ForcedAir>SystemAssessmentandMaintenance5.3003.20h-Compressoramperage
5.3003.20h-CompressoramperageDesiredOutcome:Electricalcomponentsproperlytested
Specification(s):AmperagewillbewithinOEMspecificationsand/orcoderequirements
Objective(s):Ensureequipmentoperatesasdesigned
Ensureequipmentoperatesefficiently
Ensureequipmentoperatessafely
HeatingandCooling>ForcedAir>SystemAssessmentandMaintenance5.3003.20i-Doorswitchoperation
5.3003.20i-DoorswitchoperationDesiredOutcome:Electricalcomponentsproperlytested
Specification(s):Blowercompartmentsafetyswitchoperationwillbeverified
Objective(s):Ensureblowerdoesnotoperateduringservice
HeatingandCooling>ForcedAir>SystemAssessmentandMaintenance5.3003.20j-Heatpump:emergencyheat
5.3003.20j-Heatpump:emergencyheatDesiredOutcome:Electricalcomponentsproperlytested
Specification(s):Emergencyheatcircuitfunctionswillbeverified
AmperagewillbewithinOEMspecificationsand/orcoderequirements
Objective(s):Ensuresystemdeliversheatincaseofacompressorfailure
HeatingandCooling>ForcedAir>SystemAssessmentandMaintenance
5.3003.21-AirFlow—LowRiseDesiredOutcome:Airflowisproperlytested
Note:
HeatingandCooling>ForcedAir>SystemAssessmentandMaintenance5.3003.21a-Validateairdistributionsysteminstallation
5.3003.21a-ValidateairdistributionsysteminstallationDesiredOutcome:Airflowisproperlytested
Specification(s):Systemwillbecheckedforexistenceofspecifiedsystemcomponents
Objective(s):Confirminstalledsystem
Becomefamiliarwithsystemcomponents
Verifysystemreadinessfortesting
HeatingandCooling>ForcedAir>SystemAssessmentandMaintenance5.3003.21b-Testingequipmentselection
5.3003.21b-TestingequipmentselectionDesiredOutcome:Airflowisproperlytested
Specification(s):Measurementequipmentwillbeselectedsothatdesignvaluewillbewithintheaccuraterangeofthemeasuringdevice
Equipmentwillbecapableofaccuratelymeasuring+/-10%ingeneralcase
Measurementequipmentwillbecalibratedandfieldcheckedinaccordancewithmanufacturerrecommendations
Objective(s):Ensureaccuratemeasurementsofairflowrates
HeatingandCooling>ForcedAir>SystemAssessmentandMaintenance5.3003.21c-Testairhandlerunit
5.3003.21c-TestairhandlerunitDesiredOutcome:Airflowisproperlytested
Specification(s):Equipmenttestingwillcheckfor:
Properoperation(programmedschedule/sequenceofoperation)Properrotation
Allmeasuredvalueswillberecordedandcomparedagainstdesignspecifications
Fanflowwillbeadjustedtomeetdesignspecification
Objective(s):Verifyperformanceofairhandlersystem
HeatingandCooling>ForcedAir>SystemAssessmentandMaintenance5.3003.21d-Totalairflow
5.3003.21d-TotalairflowDesiredOutcome:Airflowisproperlytested
Specification(s):TotalsystemairflowwillbemeasuredinaccordancewithANSI/ACCAStandard5orANSI/ASHRAEStandard111andadjustedtomeetdesignrequirements
Examplesofacceptablemethodsincludethefollowing:
TemperaturerisetestAirflowplate(e.g.,TrueFlow®AirHandlerFlowMeter)Fanpressurizationdevice(e.g.,DuctBlaster®,DuctTester)Hotwireanemometer
Objective(s):Ensureequipmentoperatesasdesigned
Ensureequipmentoperatesefficiently
Ensureequipmentprovidescomfort
Ensureequipmentoperatessafely
Ensureequipmentisdurable
HeatingandCooling>ForcedAir>SystemAssessmentandMaintenance5.3003.21e-Externalstaticpressure
5.3003.21e-ExternalstaticpressureDesiredOutcome:Airflowisproperlytested
Specification(s):Externalstaticpressurewillbeinaccordancewithmanufacturerspecifications
Objective(s):Ensureequipmentoperatesasdesigned
Ensureequipmentoperatesefficiently
Ensureequipmentprovidescomfort
Ensureequipmentoperatessafely
Ensureequipmentisdurable
HeatingandCooling>ForcedAir>SystemAssessmentandMaintenance5.3003.21f-Pressuredrop:coil
5.3003.21f-Pressuredrop:coilDesiredOutcome:Airflowisproperlytested
Specification(s):Pressuredropacrosscoolingcoilswillbeinaccordancewithmanufacturerspecifications
Objective(s):Ensureequipmentoperatesasdesigned
Ensureequipmentoperatesefficiently
Ensureequipmentprovidescomfort
Ensureequipmentoperatessafely
Ensureequipmentisdurable
HeatingandCooling>ForcedAir>SystemAssessmentandMaintenance5.3003.21g-Pressuredrop:filter
5.3003.21g-Pressuredrop:filterDesiredOutcome:Airflowisproperlytested
Specification(s):Pressuredropacrossfilterwillbeinaccordancewithmanufacturerspecifications
Objective(s):Ensureequipmentoperatesasdesigned
Ensureequipmentoperatesefficiently
Ensureequipmentprovidescomfort
Ensureequipmentoperatessafely
Ensureequipmentisdurable
HeatingandCooling>ForcedAir>SystemAssessmentandMaintenance5.3003.21h-Balanceofroomflow:newductwork
5.3003.21h-Balanceofroomflow:newductworkDesiredOutcome:Airflowisproperlytested
Specification(s):AirflowwillbemeasuredinaccordancewithANSI/ACCAStandard5orANSI/ASHRAEStandard111andadjustedtomeetdesignrequirements
Examplesofacceptablemethodsincludethefollowing:
AirflowwillbemeasuredateachregisterandcomparedtoloadcalculationtoensureproperairflowdeliveryAdjustmentswillbemadetofanspeed,dampers,andregistersuntildesignspecificationsaremet
Objective(s):Ensureequipmentoperatesasdesigned
Ensureequipmentoperatesefficiently
Ensureequipmentprovidescomfort
Ensureequipmentoperatessafely
Ensureequipmentisdurable
HeatingandCooling>ForcedAir>SystemAssessmentandMaintenance5.3003.21i-Supplywetbulbanddrybulb
5.3003.21i-SupplywetbulbanddrybulbDesiredOutcome:Airflowisproperlytested
Specification(s):Supplywetbulbanddrybulbairtemperatureswillberecorded
Objective(s):Ensureequipmentoperatesasdesigned
Ensureequipmentoperatesefficiently
Ensureequipmentprovidescomfort
Ensureequipmentoperatessafely
Ensureequipmentisdurable
NMvariancestates:
"Supplyandreturndrybulbairtemperatureswillberecorded."
HeatingandCooling>ForcedAir>SystemAssessmentandMaintenance5.3003.21j-Returnwetbulbanddrybulb
5.3003.21j-ReturnwetbulbanddrybulbDesiredOutcome:Airflowisproperlytested
Specification(s):Returnwetbulbanddrybulbairtemperatureswillberecorded
Objective(s):Ensureequipmentoperatesasdesigned
Ensureequipmentoperatesefficiently
Ensureequipmentprovidescomfort
Ensureequipmentoperatessafely
Ensureequipmentisdurable
HeatingandCooling>ForcedAir>SystemAssessmentandMaintenance5.3003.21k-Temperaturerise:gasandoilfurnacesonly
5.3003.21k-Temperaturerise:gasandoilfurnacesonlyDesiredOutcome:Airflowisproperlytested
Specification(s):Temperaturerisebetweenthesupplyandreturnwillbeinaccordancewithmanufacturerspecifications
Objective(s):Ensureequipmentoperatesasdesigned
Ensureequipmentoperatesefficiently
Ensureequipmentprovidescomfort
Ensureequipmentoperatessafely
Ensureequipmentisdurable
HeatingandCooling>ForcedAir>SystemAssessmentandMaintenance5.3003.21l-Finalbalance
5.3003.21l-FinalbalanceDesiredOutcome:Airflowisproperlytested
Specification(s):Finalairflowand/orpressurewillbemeasured,confirmed,andrecordedatairhandlerandregisters
AirflowwillbemeasuredinaccordancewithANSI/ACCAStandard5orANSI/ASHRAEStandard111andadjustedtomeetdesignrequirements
Objective(s):Provideacceptablethermalcomfort,energyefficiency,andindoorairquality
HeatingandCooling>ForcedAir>SystemAssessmentandMaintenance5.3003.21m-Occupant/propertymanagereducation
5.3003.21m-Occupant/propertymanagereducationDesiredOutcome:Airflowisproperlytested
Specification(s):Occupant/propertymanagerwillbe:
InstructedonproperoperationandmaintenanceproceduresEducatedonvalueandneedforrecommissioningrequirementsPropertymanagerwillcompletea30-hourOSHAsafetyeducationcourse
Objective(s):Ensurecontinuedoperationofequipmentatdesignperformancelevels
HeatingandCooling>ForcedAir>SystemAssessmentandMaintenance
5.3003.22-CombustionAnalysis—LowRiseDesiredOutcome:Analysisoncriticalcomponentsandoperationsiscompletedtoindustryandmanufacturerspecifications
Note:
HeatingandCooling>ForcedAir>SystemAssessmentandMaintenance5.3003.22a-Testingequipmentselection
5.3003.22a-TestingequipmentselectionDesiredOutcome:Analysisoncriticalcomponentsandoperationsiscompletedtoindustryandmanufacturerspecifications
Specification(s):Measurementequipmentwillbeselectedsothatdesignvaluewillbewithintheaccuraterangeofthemeasuringdevice
Equipmentwillbecapableofaccuratelymeasuring+/-10%ingeneralcase
Measurementequipmentwillbecalibratedandfieldcheckedinaccordancewithmanufacturerrecommendations
Objective(s):Ensureaccuratemeasurementsofcombustionby-products
HeatingandCooling>ForcedAir>SystemAssessmentandMaintenance5.3003.22b-Combustionanalysisprotocol
5.3003.22b-CombustionanalysisprotocolDesiredOutcome:Analysisoncriticalcomponentsandoperationsiscompletedtoindustryandmanufacturerspecifications
Specification(s):CombustionanalysiswillbeperformedinaccordancewithmanufacturerspecificationsandANSI/ACCAStandard5
Objective(s):Ensureaccuratemeasurementsofcombustionby-products
HeatingandCooling>ForcedAir>SystemAssessmentandMaintenance5.3003.22c-Oilsystem:nozzlesize
5.3003.22c-Oilsystem:nozzlesizeDesiredOutcome:Analysisoncriticalcomponentsandoperationsiscompletedtoindustryandmanufacturerspecifications
Specification(s):Nozzlesize/sprayangle/spraypatternwillbecorrectfordesigninputandwithinequipmentfiringrateoftheheatingsystemmanufacturer
Objective(s):Ensureequipmentoperatesasdesigned
Ensureequipmentoperatessafely
Ensureequipmentoperatesefficiently
Ensureequipmentisdurable
HeatingandCooling>ForcedAir>SystemAssessmentandMaintenance5.3003.22d-Naturalgas/propanesystem:burnerorifice(s)size
5.3003.22d-Naturalgas/propanesystem:burnerorifice(s)sizeDesiredOutcome:Analysisoncriticalcomponentsandoperationsiscompletedtoindustryandmanufacturerspecifications
Specification(s):Burnerorifice(s)sizewillbeinaccordancewithmanufacturerspecification
Objective(s):Ensureequipmentoperatesasdesigned
Ensureequipmentoperatessafely
Ensureequipmentoperatesefficiently
Ensureequipmentisdurable
HeatingandCooling>ForcedAir>SystemAssessmentandMaintenance5.3003.22e-Combustionairadjustment
5.3003.22e-CombustionairadjustmentDesiredOutcome:Analysisoncriticalcomponentsandoperationsiscompletedtoindustryandmanufacturerspecifications
Specification(s):Combustionairsettingwillbeinaccordancewithmanufacturer'srecommendationsandmodifiedbasedoncombustionanalysistesting
Objective(s):Ensureequipmentoperatesasdesigned
Ensureequipmentoperatessafely
Ensureequipmentoperatesefficiently
Ensureequipmentisdurable
HeatingandCooling>ForcedAir>SystemAssessmentandMaintenance5.3003.22f-Fuelpressure/gaspressure
5.3003.22f-Fuelpressure/gaspressureDesiredOutcome:Analysisoncriticalcomponentsandoperationsiscompletedtoindustryandmanufacturerspecifications
Specification(s):Measurementwillbeverifiedinaccordancewithmanufacturerspecifications
Objective(s):Ensureequipmentoperatesasdesigned
Ensureequipmentoperatessafely
Ensureequipmentoperatesefficiently
Ensureequipmentisdurable
HeatingandCooling>ForcedAir>SystemAssessmentandMaintenance5.3003.22h-Steadystateefficiency(SSE)
5.3003.22h-Steadystateefficiency(SSE)DesiredOutcome:Analysisoncriticalcomponentsandoperationsiscompletedtoindustryandmanufacturerspecifications
Specification(s):Onceburnerhasrunforfivetotenminutes,performaSSEtestwithaproperlycalibratedcombustionanalyzer
Measurementwillbeverifiedinaccordancewithmanufacturerspecifications
Objective(s):Ensureequipmentoperatesasdesigned
Ensureequipmentoperatessafely
Ensureequipmentoperatesefficiently
Ensureequipmentisdurable
HeatingandCooling>ForcedAir>SystemAssessmentandMaintenance5.3003.22i-Netstacktemperature
5.3003.22i-NetstacktemperatureDesiredOutcome:Analysisoncriticalcomponentsandoperationsiscompletedtoindustryandmanufacturerspecifications
Specification(s):Netstacktemperaturewillbemeasuredandverifiedinaccordancewithmanufacturerspecifications
Objective(s):Ensureequipmentoperatesasdesigned
Ensureequipmentoperatessafely
Ensureequipmentoperatesefficiently
Ensureequipmentisdurable
HeatingandCooling>ForcedAir>SystemAssessmentandMaintenance5.3003.22j-Carbondioxideandoxygen
5.3003.22j-CarbondioxideandoxygenDesiredOutcome:
Analysisoncriticalcomponentsandoperationsiscompletedtoindustryandmanufacturerspecifications
Specification(s):Measurementwillbeverifiedinaccordancewithindustrymanuals(e.g.,Testo,Bacharach)andmanufacturerspecifications
Objective(s):Ensureequipmentoperatesasdesigned
Ensureequipmentoperatessafely
Ensureequipmentoperatesefficiently
Ensureequipmentisdurable
HeatingandCooling>ForcedAir>SystemAssessmentandMaintenance5.3003.22k-Excessair
5.3003.22k-ExcessairDesiredOutcome:Analysisoncriticalcomponentsandoperationsiscompletedtoindustryandmanufacturerspecifications
Specification(s):Excessairwillbecalculatedandshowninaccordancewithindustrymanuals(e.g.,Testo,Bacharach)andmanufacturerspecifications
Objective(s):Ensureequipmentoperatesasdesigned
Ensureequipmentoperatessafely
Ensureequipmentoperatesefficiently
Ensureequipmentisdurable
HeatingandCooling>ForcedAir>SystemAssessmentandMaintenance5.3003.22l-Carbonmonoxide(CO)influegas
5.3003.22l-Carbonmonoxide(CO)influegasDesiredOutcome:Analysisoncriticalcomponentsandoperationsiscompletedtoindustryandmanufacturerspecifications
Specification(s):COintheundilutedfluegaswillbelessthanlevelspecifiedintheapplicablesubsectionofANSIZ21
Objective(s):Ensureequipmentoperatesasdesigned
Ensureequipmentoperatessafely
Ensureequipmentoperatesefficiently
Ensureequipmentisdurable
HeatingandCooling>ForcedAir>SystemAssessmentandMaintenance
5.3003.24-EvaporativeCoolerMaintenanceandRepairs—LowRiseDesiredOutcome:Evaporativecoolerevaluatedandmaintainedasneeded
Note:
HeatingandCooling>ForcedAir>SystemAssessmentandMaintenance5.3003.24a-Assessmentanddiagnosis
5.3003.24a-AssessmentanddiagnosisDesiredOutcome:Evaporativecoolerevaluatedandmaintainedasneeded
Specification(s):Thefollowingsystemelementswillbeassessed:
PumpPanSpiderFloatDamperRoofjack,roofsupportWaterlineWatervalveElectricalPadsMotorFan
Elementswillberepairedorreplacedasneeded
Objective(s):Ensureequipmentoperatesasdesigned
Ensureequipmentoperatessafely
Ensureequipmentoperatesefficiently
Ensureequipmentisdurable
HeatingandCooling>ForcedAir>SystemAssessmentandMaintenance5.3003.24b-Repairandmaintenance
5.3003.24b-RepairandmaintenanceDesiredOutcome:Evaporativecoolerevaluatedandmaintainedasneeded
Specification(s):Calciumdepositswillberemoved
Padswillbereplaced
Anyadditionalrepairsorreplacementswillbemadeasnecessary
Systemwillbedrainedattheendofthecoolingseason
Objective(s):
Ensureevaporativecoolerfunctionsproperly
Ensuresystemisdurable
Preventfreezing
HeatingandCooling>ForcedAir>SystemAssessmentandMaintenance5.3003.24c-Occupanteducation
5.3003.24c-OccupanteducationDesiredOutcome:Evaporativecoolerevaluatedandmaintainedasneeded
Specification(s):Aregularserviceschedulewillberecommendedtooccupant
Issuesregardingmultiplesystemsrunningwillbediscussedwithoccupant
Objective(s):Ensureoccupantunderstandsbasicoperationandimportanceofregularmaintenance
HeatingandCooling>ForcedAir>SystemAssessmentandMaintenance
5.3003.34-FuelDeliverySystemforNaturalGasandPropane—LowRiseDesiredOutcome:Naturalgasandpropanedeliveredsafelyandinsufficientamounts
Note:Theauthorityhavingjurisdictionmayrequirethatalicensedprofessionalperformcertaintasksoutlinedinthisdetail.
HeatingandCooling>ForcedAir>SystemAssessmentandMaintenance5.3003.34a-Materialandsupport
5.3003.34a-MaterialandsupportDesiredOutcome:Naturalgasandpropanedeliveredsafelyandinsufficientamounts
Specification(s):AnapprovedpipetypeinaccordancewithNFPAwillbeinstalledandsupported
Manualgasshutoffvalve,unionjoint,anddriplegwillbeverifiedorinstalled
Allworkwillbedonebyalicensedprofessionalorqualifiedperson
Objective(s):Preventcorrosion
Deliverfueltothesystem
Ensurematerialdoesnotsagorleak
HeatingandCooling>ForcedAir>SystemAssessmentandMaintenance5.3003.34b-Size
5.3003.34b-SizeDesiredOutcome:Naturalgasandpropanedeliveredsafelyandinsufficientamounts
Specification(s):Gaspipes(buildingmainandequipmentdrops)willbeinstalledforthetotalconnectedloadofallappliancesinaccordancewithNFPA
Allworkwillbedonebyalicensedprofessionalorqualifiedperson
Objective(s):Providesufficientgasflowandpressuretoalloftheappliances
HeatingandCooling>ForcedAir>SystemAssessmentandMaintenance5.3003.34c-Sealant
5.3003.34c-SealantDesiredOutcome:Naturalgasandpropanedeliveredsafelyandinsufficientamounts
Specification(s):Pipeswillbesealedwithanapprovedfasteningprocessandsealantinaccordancewithmanufacturerspecifications
Gaslineswillbeleakfreewhentestedwithanelectroniccombustiblegasleakdetectorandverifiedwithbubblesolution
Gaslineswillbeleakfreewhentestedbylocalcode-approvedstandingpressuretest
Allworkwillbedonebyalicensedprofessional,orqualifiedperson
Objective(s):Installgaslineswithnoleaks
HeatingandCooling>ForcedAir>SystemAssessmentandMaintenance5.3003.34d-Safetydevicesforpropane
5.3003.34d-SafetydevicesforpropaneDesiredOutcome:Naturalgasandpropanedeliveredsafelyandinsufficientamounts
Specification(s):Asecondarygasvalvesafetydetectorwillbeinstalledforpropanepipinginstalledbelowgrade
Allworkwillbedonebyalicensedprofessionalorqualifiedperson
Objective(s):Detectaccumulationofdangerouslevelsofpropaneinareasthatarebelowgrade
HeatingandCooling>ForcedAir>SystemAssessmentandMaintenance
5.3003.35-CombustionApplianceVentingSystem—LowRiseDesiredOutcome:Combustionproductsareproperlyventedtotheoutdoors
Note:
HeatingandCooling>ForcedAir>SystemAssessmentandMaintenance5.3003.35a-Combustionair
5.3003.35a-CombustionairDesiredOutcome:Combustionproductsareproperlyventedtotheoutdoors
Specification(s):Combustionsupply/exhaustairopeningwillbeincompliancewithapplicableNFPAstandardsorlocalcode
Objective(s):Exhaustcombustionproductstotheoutdoors
Ensureworkdoesnotdamagebuilding
Protectworkersandoccupantsfrominjury
HeatingandCooling>ForcedAir>SystemAssessmentandMaintenance5.3003.35b-Flueventmaterial
5.3003.35b-FlueventmaterialDesiredOutcome:Combustionproductsareproperlyventedtotheoutdoors
Specification(s):Flueventmaterialwillbeselectedtopreventfluegasfreezingand/orcorrosion(usingdoublewall,wherenecessary)
Cost-effectivematerialswillbeusedwhenappropriateandallowable
Objective(s):Ensuredurabilityofflueventsystem
Ensureselectedmaterialisappropriateandcost-effective
HeatingandCooling>ForcedAir>SystemAssessmentandMaintenance5.3003.35c-Installation
5.3003.35c-InstallationDesiredOutcome:Combustionproductsareproperlyventedtotheoutdoors
Specification(s):Ventingsystemswillbeinstalledconsideringpropermaterial,pitch,commonventing,chimneyliner,clearance,totalequivalentlength,andterminationinaccordancewithNFPA54,31,211
CategoryIventingsystemswillbeinstalledinaccordancewithNFPA54/ANSIZ223.1
CategoryIIIandIVventingsystemswillbeinstalledinaccordancewiththemanufacturerspecifications
Terminationswillbelocatedawayfromwindows,doors,andwalkways
Aestheticsandnoisewillbeconsidered
Ventingwillberoutedintheshortestandmostdirectpathpossible
Ventjointswillbeairtightandwatertight
Objective(s):Exhaustcombustionproductstotheoutdoors
Ensureworkdoesnotdamagebuilding
Protectworkersandoccupantsfrominjury
HeatingandCooling>ForcedAir>SystemAssessmentandMaintenance5.3003.35d-Orphanedequipment
5.3003.35d-OrphanedequipmentDesiredOutcome:Combustionproductsareproperlyventedtotheoutdoors
Specification(s):ExistingventsystemorchimneywillberesizedorrelinedinaccordancewiththeapplicableNFPAstandardwhenoneormorecommonventedappliancesareremoved
Objective(s):Exhaustcombustionproductstotheoutdoors
Ensureworkdoesnotdamagebuilding
Protectworkersandoccupantsfrominjury
HeatingandCooling>ForcedAir>SystemAssessmentandMaintenance
5.3003.36-DuctworkSystem—LowRiseDesiredOutcome:Theductsystemsafelysupportspeakoperationoftheequipment
HeatingandCooling>ForcedAir>SystemAssessmentandMaintenance5.3003.36a-Location:indoor(supplyducts)ductsectionlocatedcompletelywithinthethermalboundaryofthebuilding
5.3003.36a-Location:indoor(supplyducts)ductsectionlocatedcompletelywithinthethermalboundaryofthebuildingDesiredOutcome:Theductsystemsafelysupportspeakoperationoftheequipment
Specification(s):DuctmaterialwillbeinstalledwithanR-valuecompliantwithcode
Anappropriatevaporretarderwillbeinstalled
Objective(s):Preventcondensationontheoutsideoftheductwork
HeatingandCooling>ForcedAir>SystemAssessmentandMaintenance5.3003.36b-Location:outdoorsductsectionlocatedoutsideofthethermalboundaryofthebuildingorinquasi-
conditionedspaces
5.3003.36b-Location:outdoorsductsectionlocatedoutsideofthethermalboundaryofthebuildingorinquasi-conditionedspacesDesiredOutcome:Theductsystemsafelysupportspeakoperationoftheequipment
Specification(s):Ductmaterialwillbeselectedthatmeetsthefollowingcriteria:
AninsulationlevelcompliantwithcodePermeabilitythatpreventscondensationPermeabilitythatreducesheatlossorgainfromtheductwork
Objective(s):Preventcondensationontheoutsideoftheductwork
Reducethermallossorgainfromtheductwork
HeatingandCooling>ForcedAir>SystemAssessmentandMaintenance5.3003.36c-Buildingcavitiesusedasductwork
5.3003.36c-BuildingcavitiesusedasductworkDesiredOutcome:Theductsystemsafelysupportspeakoperationoftheequipment
Specification(s):
Whenviablebuildingcavitiesusedasductworkwillbereplacedwithproperlysizedconventionalductmaterial
Whenreplacementisnotanoption,buildingcavitiesusedasductworkwillbesealedwhenaccessible
Objective(s):Safeguardindoorenvironmentalquality
Maximizeairflow
Minimizeenergyuse
HeatingandCooling>ForcedAir>SystemAssessmentandMaintenance5.3003.36d-Firerating
5.3003.36d-FireratingDesiredOutcome:Theductsystemsafelysupportspeakoperationoftheequipment
Specification(s):Ductswillbeinstalledinaccordancewiththefireratingoflocalcodes
Objective(s):Preventafirehazard
HeatingandCooling>ForcedAir>SystemAssessmentandMaintenance5.3003.36e-Penetrations
5.3003.36e-PenetrationsDesiredOutcome:Theductsystemsafelysupportspeakoperationoftheequipment
Specification(s):Interiorwallpenetrationsforductworkwillbesealedwithadurablesealant(e.g.,caulk,silicone,foam)
Penetrationsthroughfirewallsandfloorswillbesealedwithafire-ratedmaterial
Objective(s):Preventafirehazard
HeatingandCooling>ForcedAir>SystemAssessmentandMaintenance5.3003.36f-Support
5.3003.36f-SupportDesiredOutcome:Theductsystemsafelysupportspeakoperationoftheequipment
Specification(s):DuctworkwillbesupportedinamannerthatdoesnotconstrictductworkorductinsulationperSMACNAductconstructionstandards(ADCforflexibleductorNAIMAforfiberglassduct)
Objective(s):Ensureductsdonotsag,bend,trapwater,orexperiencediminishedairflow
HeatingandCooling>ForcedAir>SystemAssessmentandMaintenance5.3003.36g-Protection
5.3003.36g-ProtectionDesiredOutcome:Theductsystemsafelysupportspeakoperationoftheequipment
Specification(s):Ductswillberoutedsuchthatserviceandrepairtothebuildinganditssystemsdoesnotdamagetheducts
Objective(s):Protectequipmentfromdamage
Ensureequipmentoperatesasdesigned
HeatingandCooling>ForcedAir>SystemAssessmentandMaintenance5.3003.36h-Fastening:metaltoflexibleduct
5.3003.36h-Fastening:metaltoflexibleductDesiredOutcome:Theductsystemsafelysupportspeakoperationoftheequipment
Specification(s):Flexibleduct-to-metalconnectionswillbefastenedwithtiebandsusingatiebandtensioningtool
Beadedcollarswillbeinstalledforallsheetmetaltoflexibleductconnections
Masticwillbeappliedtointeriorflexliningtometalconnection
Manufacturerspecificationswillbefollowed
Objective(s):Ensureductconnectionsaredurable
HeatingandCooling>ForcedAir>SystemAssessmentandMaintenance5.3003.36i-Fastening:metaltometal
5.3003.36i-Fastening:metaltometalDesiredOutcome:Theductsystemsafelysupportspeakoperationoftheequipment
Specification(s):Metal-to-metalconnectionswillbefastenedwithequallyspacedmechanicalfasteners
Gapslargerthan1/4"willbebridgedwithsheetmetal
Jointswillbesealedwithmastic
Jointssmallerthan1/4"willbesealedwithNFPA90AandBapprovedsealant
Objective(s):Ensureductconnectionsaredurable
HeatingandCooling>ForcedAir>SystemAssessmentandMaintenance
5.3003.36j-Fastening:ductboardtometal
5.3003.36j-Fastening:ductboardtometalDesiredOutcome:Theductsystemsafelysupportspeakoperationoftheequipment
Specification(s):Ductboardtometalconnectionswillbefastenedwithmechanicalfasteners
JointsandconnectionswillbesealedwithUL181Alistedtapesormastics
Objective(s):Ensureductconnectionsaredurable
HeatingandCooling>ForcedAir>SystemAssessmentandMaintenance5.3003.36k-Fastening:boottobuildingconnection
5.3003.36k-Fastening:boottobuildingconnectionDesiredOutcome:Theductsystemsafelysupportspeakoperationoftheequipment
Specification(s):Bootswillbefastenedtothebuildingwithmechanicalfasteners
Connectionwillbesealedwithmastic,caulk,orgaskets
Objective(s):Ensureductconnectionsaredurable
Properlysealthebootstominimizeairleakage
HeatingandCooling>ForcedAir>SystemAssessmentandMaintenance5.3003.36l-Terminations
5.3003.36l-TerminationsDesiredOutcome:Theductsystemsafelysupportspeakoperationoftheequipment
Specification(s):Terminationscapableofdeliveringairwithproperspeedandthrowof80-120%ofthefarthestwall,floor,orceilingwillbeselected
SelectionswillbebasedonANSI/ACCAManualTAirDistributionBasics
Objective(s):Deliverandproperlymixairinthebuilding
HeatingandCooling>ForcedAir>SystemAssessmentandMaintenance5.3003.36m-Filtration
5.3003.36m-FiltrationDesiredOutcome:
Theductsystemsafelysupportspeakoperationoftheequipment
Specification(s):Filterbypasseswillbeeliminated
Airtightfilterslotcoverswillbeinstalledtopreventreturnairleakageincombustionappliancezone
Filterswillbechanged
Filterswithhighstaticpressuredropswillbeavoided
Avisualinspectionforexcessivedustanddebriswillbeperformed,andductswillbecleanedaccordingly
Objective(s):Protectequipmentfromdirtanddebris
Allowforproperairflow
HeatingandCooling>ForcedAir>SystemAssessmentandMaintenance5.3003.36n-Externalstaticpressure
5.3003.36n-ExternalstaticpressureDesiredOutcome:Theductsystemsafelysupportspeakoperationoftheequipment
Specification(s):Ductwork,filter,andotherequipmentwillbeinstalledsototalexternalstaticpressuredoesnotexceedmanufacturerspecifications
Objective(s):Ensureequipmentoperatesasdesigned
HeatingandCooling>ForcedAir>SystemAssessmentandMaintenance5.3003.36o-Airflow:coolingandheatpumpsystems
5.3003.36o-Airflow:coolingandheatpumpsystemsDesiredOutcome:Theductsystemsafelysupportspeakoperationoftheequipment
Specification(s):Measuredairflowpertonwillmeetmanufacturerspecifications
AirflowwillbeestablishedinaccordancewithANSI/ACCA5QIHVACQualityInstallationSpecificationandASHRAEStandards
Objective(s):Ensureequipmentoperatesasdesigned
HeatingandCooling>ForcedAir>SystemAssessmentandMaintenance5.3003.36p-Temperaturerise:heating-onlysystems
5.3003.36p-Temperaturerise:heating-onlysystemsDesiredOutcome:
Theductsystemsafelysupportspeakoperationoftheequipment
Specification(s):Temperaturerisewillbemeasured,andtheresultwillbeinaccordancewithmanufacturerspecifications
Objective(s):Ensureequipmentoperatesasdesigned
HeatingandCooling>ForcedAir>SystemAssessmentandMaintenance5.3003.36q-Systemprotectionduringconstructionandrenovation
5.3003.36q-SystemprotectionduringconstructionandrenovationDesiredOutcome:Theductsystemsafelysupportspeakoperationoftheequipment
Specification(s):Registers,grilles,anddiffuserswillbeblocked,masked,orotherwisesealedwithadurablematerial
Useofsystemwillnotbeallowedduringrenovationorconstruction
Contractorandoccupantwillbeeducatedonnecessityofprotectingtheequipment
Objective(s):Protectequipmentandoccupantsfromdebrisinthesystem
HeatingandCooling>ForcedAir>SystemAssessmentandMaintenance5.3003.36r-Roompressurebalancing
5.3003.36r-RoompressurebalancingDesiredOutcome:Theductsystemsafelysupportspeakoperationoftheequipment
Specification(s):Anappropriatemeansofpressurebalancingwillbeinstalled(e.g.,transfergrilles,jumperducts,individualroomreturns)
Room-to-roompressuredifferencesshallnotexceed+/-3pascalswiththeairhandlerrunning
Objective(s):Ensuresystemhasunrestrictedairflowbetweensuppliesandreturns
Minimizeinfiltrationandexfiltrationcausedbysystem
Preventinterferencewithsafeoperationofcombustionappliances
HeatingandCooling>ForcedAir>SystemAssessmentandMaintenance5.3003.36s-Sealing:newductwork
5.3003.36s-Sealing:newductworkDesiredOutcome:Theductsystemsafelysupportspeakoperationoftheequipment
Specification(s):
Totalsystemleakage(includingairhandler)willnotexceed20%ofdesignedsystemairflow(cubicfeetperminute)whentestedat25pascals
Forpartialductsystemreplacementorimprovement,existingductworkspecificationwillbeapplied
Objective(s):Minimizesystemairleakage
HeatingandCooling>ForcedAir>SystemAssessmentandMaintenance5.3003.36t-Sealing:existingductwork
5.3003.36t-Sealing:existingductworkDesiredOutcome:Theductsystemsafelysupportspeakoperationoftheequipment
Specification(s):Accessiblejoints,cracks,seams,holes,andpenetrationswillbesealed
Objective(s):Minimizesystemairleakage
HeatingandCooling>ForcedAir>SystemAssessmentandMaintenance
5.3003.37-HeatingandCoolingControls—LowRiseDesiredOutcome:Heatingandcoolingcontrolsinstalledandsetproperly
Note:
HeatingandCooling>ForcedAir>SystemAssessmentandMaintenance5.3003.37a-Removalofmercury-basedthermostats
5.3003.37a-Removalofmercury-basedthermostatsDesiredOutcome:Heatingandcoolingcontrolsinstalledandsetproperly
Specification(s):Mercury-basedthermostatswillberemovedsafelyanddisposedofinaccordancewithEPAregulations
Objective(s):Protectworkersandoccupantsfrominjury
Protecttheenvironmentfromdamage
HeatingandCooling>ForcedAir>SystemAssessmentandMaintenance5.3003.37b-Removalofexistingcontrols
5.3003.37b-RemovalofexistingcontrolsDesiredOutcome:Heatingandcoolingcontrolsinstalledandsetproperly
Specification(s):ExistingcontrolswillberemovedinaccordancewithEPAlead-safeworkrules
Objective(s):Protectworkersandoccupantsfrominjury
Protectenvironmentfromdamage
HeatingandCooling>ForcedAir>SystemAssessmentandMaintenance5.3003.37c-Penetrations
5.3003.37c-PenetrationsDesiredOutcome:Heatingandcoolingcontrolsinstalledandsetproperly
Specification(s):Penetrationsforcontrolwiringwillbesealedwithadurablesealant(e.g.,caulk,silicone,foam)
Penetrationsthroughfirewallswillbesealedwithafire-ratedmaterial
Objective(s):Ensurecontrolsoperateasdesigned
Minimizeinfiltrationandexfiltrationfrombuilding
Preventpestinfestation
HeatingandCooling>ForcedAir>SystemAssessmentandMaintenance5.3003.37d-Thermostatlocation
5.3003.37d-ThermostatlocationDesiredOutcome:Heatingandcoolingcontrolsinstalledandsetproperly
Specification(s):Thermostatswillbeinstalledtoreflectthetemperatureofthezoneinwhichtheyareinstalled
Thermostatswillnotbeexposedtoextremetemperatures,radiantheatsources,warm/coldwalls,anddrafts
Objective(s):Ensurecontrolsoperateasdesigned
HeatingandCooling>ForcedAir>SystemAssessmentandMaintenance5.3003.37e-Blowerspeed
5.3003.37e-BlowerspeedDesiredOutcome:Heatingandcoolingcontrolsinstalledandsetproperly
Specification(s):TotalairflowwillbemeasuredinaccordancewithANSI/ACCAStandard5orANSI/ASHRAEStandard111andadjustedtomeetdesignrequirements
Objective(s):Ensuretheequipmenthascorrectairflow
HeatingandCooling>ForcedAir>SystemAssessmentandMaintenance5.3003.37f-Thermostatselection:heatpump
5.3003.37f-Thermostatselection:heatpumpDesiredOutcome:Heatingandcoolingcontrolsinstalledandsetproperly
Specification(s):Athermostatwithequipmentsupplementaryheatlockoutthatcaninterfacewithanoutdoortemperaturesensorwillbeselected
Objective(s):Maximizetheheatingoutputofthecompressor(heatpumpmodeeliminatessupplementaryheat)toachieveenergyefficiency
HeatingandCooling>ForcedAir>SystemAssessmentandMaintenance5.3003.37g-Heatpump:supplementaryheat
5.3003.37g-Heatpump:supplementaryheatDesiredOutcome:Heatingandcoolingcontrolsinstalledandsetproperly
Specification(s):ThermalandeconomicbalancepointwillbecalculatedandanoptimumthermalbalancepointwillbeselectedinaccordancewithANSI/ACCAManualS
Thedesignofvariablerefrigerantflowsystemsarepermittedtonotrequiresupplementaryheat
Objective(s):Maximizetheheatingoutput
Maximizetheheatingoutputofthecompressor(heatpumpmodeeliminatessupplementaryheat)toachieveenergyefficiency
HeatingandCooling>ForcedAir>SystemAssessmentandMaintenance5.3003.37h-Heatpump:outdoortemperaturesensor
5.3003.37h-Heatpump:outdoortemperaturesensorDesiredOutcome:Heatingandcoolingcontrolsinstalledandsetproperly
Specification(s):Anoutdoortemperaturesensorwillbeinstalledinaccordancewithmanufacturerspecifications
Objective(s):Ensureequipmentoperatesasdesigned
HeatingandCooling>ForcedAir>SystemAssessmentandMaintenance5.3003.37i-Heatpump:supplementaryheatcontrolwiring
5.3003.37i-Heatpump:supplementaryheatcontrolwiringDesiredOutcome:Heatingandcoolingcontrolsinstalledandsetproperly
Specification(s):Supplementaryheatwillbewiredontosecondstageheatingterminal(W2)
Objective(s):Donotoperatesupplementaryheatinstageoneheating
HeatingandCooling>ForcedAir>SystemAssessmentandMaintenance5.3003.37j-Thermostat:installerprogramming
5.3003.37j-Thermostat:installerprogrammingDesiredOutcome:Heatingandcoolingcontrolsinstalledandsetproperly
Specification(s):Theinstalleroptionswillbesettomatchthethermostattotheequipmentandcontrolboardsettings
Objective(s):Ensureequipmentoperatesasdesigned
HeatingandCooling>ForcedAir>SystemAssessmentandMaintenance5.3003.37k-Timedelaysettings
5.3003.37k-TimedelaysettingsDesiredOutcome:Heatingandcoolingcontrolsinstalledandsetproperly
Specification(s):Timedelayforequipmentwillbesetinaccordancewithmanufacturerspecificationsandasappropriatefortheclimatezone(e.g.,notimedelayforhothumidclimates)
Objective(s):Maximizethetransferoftheheatwithoutadverselyaffectingindoorhumiditylevels
HeatingandCooling>ForcedAir>SystemAssessmentandMaintenance5.3003.37l-Humidistat:location
5.3003.37l-Humidistat:locationDesiredOutcome:Heatingandcoolingcontrolsinstalledandsetproperly
Specification(s):Humidistatwillbeinstalledtoaccuratelyreflecthumidityofthezoneinwhichitisinstalled
Objective(s):Ensurecontrolsoperateasdesigned
HeatingandCooling>ForcedAir>SystemAssessmentandMaintenance5.3003.37m-Occupanteducation
5.3003.37m-OccupanteducationDesiredOutcome:Heatingandcoolingcontrolsinstalledandsetproperly
Specification(s):Occupantswillbeeducatedonproperuseofthermostat,including:
ProperuseofsetbacksforairconditionersandheatpumpsAllowingoccupantcomforttodeterminesetbackforcombustion-heatingappliancesUsingemergencyheatappropriately
Objective(s):Ensureequipmentandcontrolsoperateasdesigned
Providecomfortthroughoutbuilding
HeatingandCooling>ForcedAir>SystemAssessmentandMaintenance5.3003.37n-Centralcontroller
5.3003.37n-CentralcontrollerDesiredOutcome:Heatingandcoolingcontrolsinstalledandsetproperly
Specification(s):Wiringandsensorswillbeinstalledinaccordancewithmanufacturerspecifications
Objective(s):Educatebuildingmanagertomonitorandcontroltheentirebuilding
HeatingandCooling>ForcedAir>SystemAssessmentandMaintenance
5.3003.38-CondensateDrainageofHeatingandAirConditioningEquipment—LowRiseDesiredOutcome:Equipmentandcondensatedrainoperateasdesigned
Note:
HeatingandCooling>ForcedAir>SystemAssessmentandMaintenance5.3003.38a-Connection
5.3003.38a-ConnectionDesiredOutcome:Equipmentandcondensatedrainoperateasdesigned
Specification(s):Connectionsincondensatedrainsystemwillbewatertight
Objective(s):Ensurecondensatedrainconnectiondoesnotleak
HeatingandCooling>ForcedAir>SystemAssessmentandMaintenance5.3003.38b-Insulation
5.3003.38b-InsulationDesiredOutcome:Equipmentandcondensatedrainoperateasdesigned
Specification(s):Condensatedrainlineswillbeinsulatedwithaminimum1"ofinsulationwithavaporretarderwhenthereispotentialforcondensationorfreezingonthedrainline
Objective(s):Ensurecondensatedrainconnectionsdonotleak
HeatingandCooling>ForcedAir>SystemAssessmentandMaintenance5.3003.38c-Overflowprotection:upflow
5.3003.38c-Overflowprotection:upflowDesiredOutcome:Equipmentandcondensatedrainoperateasdesigned
Specification(s):Secondarydrainpanandfloatswitchwillbeinstalledwhenoverflowcoulddamagefinishedsurfacesorupflowsystemswillhaveafloatswitchinstalledintheprimarycondensatedrainwhenoverflowcoulddamagefinishedsurfaces
Floatswitchwillbeinterlockedwiththecoolingcircuitandwillbreakthecircuitwhenaleakoccurs
Objective(s):Ensurecondensatedrainconnectionsdonotleak
HeatingandCooling>ForcedAir>SystemAssessmentandMaintenance5.3003.38d-Pumps
5.3003.38d-PumpsDesiredOutcome:Equipmentandcondensatedrainoperateasdesigned
Specification(s):Condensatedrainpumpswillbeinstalledwhencondensatecannotbedrainedbygravity
Powersourceforpumpswillbeinstalled
Operationanddrainageofpumpwillbeverified
Objective(s):Ensurecondensatedrainconnectionsdonotleak
HeatingandCooling>ForcedAir>SystemAssessmentandMaintenance5.3003.38e-Ventsandtraps
5.3003.38e-VentsandtrapsDesiredOutcome:Equipmentandcondensatedrainoperateasdesigned
Specification(s):Ventsandtrapswillbeinstalledoncondensatedrainlines,includingcondensingheatingsystemsinaccordancewithmanufacturerspecifications
Forcombustion-heatingequipment,trapsuppliedwiththeequipmentwillbeusedinaccordancewithmanufacturerspecifications
Objective(s):Ensurecondensatedrainoperatesasdesigned
Ensurecondensatedraindoesnotleak
HeatingandCooling>ForcedAir>SystemAssessmentandMaintenance5.3003.38f-Drainpan
5.3003.38f-DrainpanDesiredOutcome:Equipmentandcondensatedrainoperateasdesigned
Specification(s):Asecondarydrainpanwillbeinstalledforallairconditioning,airhandler,orevaporatorcoilinstallationswherewaterdamagemayoccur
Thesecondarypanwillcontainadrain,whichwillberanseparatelyfromtheprimarycondensatedraintoavisibleterminationpoint
Thesecondarydrainpanwillbepitchedtowardthedrainlinetoensurethatmoistureisremovedfromthebuilding
Objective(s):
Preventwaterdamagefromamalfunctioningdrainsystem
Toalertbuildingownerormaintenancestaffthataproblemexists
HeatingandCooling>ForcedAir>SystemAssessmentandMaintenance5.3003.38g-Waterleveldetectiondevice
5.3003.38g-WaterleveldetectiondeviceDesiredOutcome:Equipmentandcondensatedrainoperateasdesigned
Specification(s):Allsecondarydrainpanswillhaveawaterleveldetectiondeviceinterlockedwiththecoolingcontrolcircuitthatshutsdowntheunitwhenaleakoccurs
Objective(s):Preventwaterfromoverflowingthepananddrainingontotheceilingbelow
HeatingandCooling>ForcedAir>SystemAssessmentandMaintenance5.3003.38h-Termination
5.3003.38h-TerminationDesiredOutcome:Equipmentandcondensatedrainoperateasdesigned
Specification(s):Condensatedrainwillbeterminatedinaccordancewithlocalcodes
Objective(s):Ensurecondensatedoesnotleakintothebuilding
Ensurecondensatedraindoesnotfreeze
HeatingandCooling>ForcedAir>SpecialConsiderations
5.3088.2-RegionalClimaticConsiderationsDesiredOutcome:Regionalclimaticvariablesaretakenintoconsideration
HeatingandCooling>ForcedAir>SpecialConsiderations5.3088.2a-Verycold
5.3088.2a-VerycoldDesiredOutcome:Regionalclimaticvariablesaretakenintoconsideration
Specification(s):Condensatelinewillbeinsulated
Verificationofproperchargewillbeconductedwhenoutdoortemperaturesaresuitable
Refrigerantchargeevaluationwillbedoneusingproperevaluationtechniques(subcooling/superheat)dependingonmeteringdeviceinaccordancewithANSI/ACCAStandard5
Refrigerantwillbeweighedintoheating,ventilation,andair-conditioning(HVAC)systemswhenoutdoortemperaturesdonotfacilitateaccuratetestingofsystemcharge
Objective(s):Preventfreezing
Ensureproperequipmentoperation
HeatingandCooling>ForcedAir>SpecialConsiderations5.3088.2b-Cold
5.3088.2b-ColdDesiredOutcome:Regionalclimaticvariablesaretakenintoconsideration
Specification(s):Condensatelinewillbeinsulated
Verificationofproperchargewillbeconductedwhenoutdoortemperaturesaresuitable
Refrigerantchargeevaluationwillbedoneusingproperevaluationtechniques(subcooling/superheat)dependingonmeteringdeviceinaccordancewithANSI/ACCAStandard5
RefrigerantwillbeweighedintoHVACsystemswhenoutdoortemperaturesdonotfacilitateaccuratetestingofsystemcharge
Objective(s):Preventfreezing
Ensureproperequipmentoperation
HeatingandCooling>ForcedAir>SpecialConsiderations5.3088.2c-Mixedhumid
5.3088.2c-MixedhumidDesiredOutcome:Regionalclimaticvariablesaretakenintoconsideration
Specification(s):RefrigerantwillbeweighedintoHVACsystemswhenoutdoortemperaturesdonotfacilitateaccuratetestingofsystemcharge
Verificationofproperchargewillbeconductedwhenoutdoortemperaturesaresuitable
Refrigerantchargeevaluationwillbedoneusingproperevaluationtechniques(subcooling/superheat)dependingonmeteringdeviceinaccordancewithANSI/ACCAStandard5
Heatingandcoolingrefrigerantlineswillbeinsulated
Objective(s):Ensureproperequipmentoperation
Preventenergylossandcondensation
HeatingandCooling>ForcedAir>SpecialConsiderations5.3088.2d-Hothumid
5.3088.2d-HothumidDesiredOutcome:Regionalclimaticvariablesaretakenintoconsideration
Specification(s):RefrigerantwillbeweighedintoHVACsystemswhenoutdoortemperaturesdonotfacilitateaccuratetestingofsystemcharge
Verificationofproperchargewillbeconductedwhenoutdoortemperaturesaresuitable
Refrigerantchargeevaluationwillbedoneusingproperevaluationtechniques(subcooling/superheat)dependingonmeteringdeviceinaccordancewithANSI/ACCAStandard5
Objective(s):Ensureproperequipmentoperation
HeatingandCooling>ForcedAir>SpecialConsiderations5.3088.2e-Marine
5.3088.2e-MarineDesiredOutcome:Regionalclimaticvariablesaretakenintoconsideration
Specification(s):RefrigerantwillbeweighedintoHVACsystemswhenoutdoortemperaturesdonotfacilitateaccuratetestingofsystemcharge
Verificationofproperchargewillbeconductedwhenoutdoortemperaturesaresuitable
Refrigerantchargeevaluationwillbedoneusingproperevaluationtechniques(subcooling/superheat)dependingonmeteringdeviceinaccordancewithANSI/ACCAStandard5
Objective(s):Ensureproperequipmentoperation
HeatingandCooling>ForcedAir>SpecialConsiderations5.3088.2f-Hotdry
5.3088.2f-HotdryDesiredOutcome:Regionalclimaticvariablesaretakenintoconsideration
Specification(s):RefrigerantwillbeweighedintoHVACsystemswhenoutdoortemperaturesdonotfacilitateaccuratetestingofsystemcharge
Verificationofproperchargewillbeconductedwhenoutdoortemperaturesaresuitable
Refrigerantchargeevaluationwillbedoneusingproperevaluationtechniques(subcooling/superheat)dependingonmeteringdeviceinaccordancewithANSI/ACCAStandard5
Objective(s):Ensureproperequipmentoperation
HeatingandCooling>ForcedAir>SpecialConsiderations
5.3088.3-RegionalClimaticConsiderations—MidandHighRiseDesiredOutcome:Regionalclimaticvariablesaretakenintoconsideration
HeatingandCooling>ForcedAir>SpecialConsiderations5.3088.3a-Verycold
5.3088.3a-VerycoldDesiredOutcome:Regionalclimaticvariablesaretakenintoconsideration
Specification(s):Individualroomswillremainatapressuredifferentialofnogreaterthan+/-3pascalswithreferencetotheindoors
Combustioninletsandoutletswillbeterminatedabovesnowlineandprotectedfromsnowcover
Roofexhaustfanswillbeinstalledwithroofcurbsthatmeetorexceedthemechanicalcoderequirements
ProperrefrigerantchargewillbeevaluatedanddocumentedaccordingtoANSI/ACCAStandard5
Examplesofacceptableproceduresthatmaybeperformedinclude:
Refrigerantwillbeweighedintoheating,ventilation,andairconditioning(HVAC)systemswhenoutdoortemperaturesdonotfacilitateaccuratetestingofsystemchargeVerificationofproperchargewillbeconductedwhenoutdoortemperaturesaresuitableRefrigerantchargeevaluationmustbedoneusingproperevaluationtechniques(subcooling/superheat)dependingonmeteringdeviceinaccordancewithANSI/ACCAStandard5
Objective(s):Avoidmoisture-relateddamagetothebuilding
Ensureoccupantsafetybyproperlyventingcombustiongasses
Ensureproperexhaustairflow
HeatingandCooling>ForcedAir>SpecialConsiderations5.3088.3b-Cold
5.3088.3b-ColdDesiredOutcome:Regionalclimaticvariablesaretakenintoconsideration
Specification(s):Combustioninletsandoutletswillbeterminatedabovesnowlineandprotectedfromsnowcover
Roofexhaustfanswillbeinstalledwithroofcurbsthatmeetorexceedthemechanicalcoderequirements
ProperrefrigerantchargewillbeevaluatedanddocumentedaccordingtoANSI/ACCAStandard5.
Examplesofacceptableproceduresthatmaybeperformedinclude:
RefrigerantwillbeweighedintoHVACsystemswhenoutdoortemperaturesdonotfacilitateaccuratetestingofsystemchargeVerificationofproperchargewillbeconductedwhenoutdoortemperaturesaresuitableRefrigerantchargeevaluationmustbedoneusingproperevaluationtechniques(subcooling/superheat)dependingonmeteringdeviceinaccordancewithANSI/ACCAStandard5
Objective(s):Ensureoccupantsafetybyproperlyventingcombustiongasses
Ensureproperexhaustairflow
HeatingandCooling>ForcedAir>SpecialConsiderations5.3088.3c-Mixedhumid
5.3088.3c-MixedhumidDesiredOutcome:Regionalclimaticvariablesaretakenintoconsideration
Specification(s):ProperrefrigerantchargewillbeevaluatedanddocumentedaccordingtoANSI/ACCAStandard5
Examplesofacceptableproceduresthatmaybeperformedinclude:
RefrigerantwillbeweighedintoHVACsystemswhenoutdoortemperaturesdonotfacilitateaccuratetestingofsystemchargeVerificationofproperchargewillbeconductedwhenoutdoortemperaturesaresuitableRefrigerantchargeevaluationmustbedoneusingproperevaluationtechniques(subcooling/superheat)dependingonmeteringdeviceinaccordancewithANSI/ACCAStandard5Heatingandcoolingrefrigerantlineswillbeinsulated
Objective(s):Ensureproperequipmentoperation
Preventenergylossandcondensation
HeatingandCooling>ForcedAir>SpecialConsiderations5.3088.3d-Hothumid
5.3088.3d-HothumidDesiredOutcome:Regionalclimaticvariablesaretakenintoconsideration
Specification(s):ProperrefrigerantchargewillbeevaluatedanddocumentedaccordingtoANSI/ACCAStandard5
Examplesofacceptableproceduresthatmaybeperformedinclude:
RefrigerantwillbeweighedintoHVACsystemswhenoutdoortemperaturesdonotfacilitateaccuratetestingofsystemchargeVerificationofproperchargewillbeconductedwhenoutdoortemperaturesaresuitableRefrigerantchargeevaluationmustbedoneusingproperevaluationtechniques(subcooling/superheat)dependingonmeteringdeviceinaccordancewithANSI/ACCAStandard5Heatingandcoolingrefrigerantlineswillbeinsulated
Objective(s):Ensureproperequipmentoperation
Preventenergylossandcondensation
HeatingandCooling>ForcedAir>SpecialConsiderations
5.3088.3f-Hotdry
5.3088.3f-HotdryDesiredOutcome:Regionalclimaticvariablesaretakenintoconsideration
Specification(s):ProperrefrigerantchargewillbeevaluatedanddocumentedaccordingtoANSI/ACCAStandard5
Examplesofacceptableproceduresthatmaybeperformedinclude:
RefrigerantwillbeweighedintoHVACsystemswhenoutdoortemperaturesdonotfacilitateaccuratetestingofsystemchargeVerificationofproperchargewillbeconductedwhenoutdoortemperaturesaresuitableRefrigerantchargeevaluationmustbedoneusingproperevaluationtechniques(subcooling/superheat)dependingonmeteringdeviceinaccordancewithANSI/ACCAStandard5Heatingandcoolingrefrigerantlineswillbeinsulated
Objective(s):Ensureproperequipmentoperation
Preventenergyloss
HeatingandCooling>HydronicHeating(HotWaterandSteam)>EquipmentInstallation
5.3102.2-VentingSealedCombustionApplianceDesiredOutcome:Fluegasesremovedsafelyandcost-efficiently
Note:
HeatingandCooling>HydronicHeating(HotWaterandSteam)>EquipmentInstallation5.3102.2a-Flueventmaterialselection
5.3102.2a-FlueventmaterialselectionDesiredOutcome:Fluegasesremovedsafelyandcost-efficiently
Specification(s):Flueventmaterialwillbeselectedtopreventfluegasfreezingand/orcorrosion(doublewallwherenecessary)inaccordancewiththeappliancemanufacturer'srequirements
Objective(s):Ensurethedurabilityofflueventsystem
Ensureselectedmaterialisappropriateandcost-effective
HeatingandCooling>HydronicHeating(HotWaterandSteam)>EquipmentInstallation5.3102.2b-Locationofventtermination
5.3102.2b-LocationofventterminationDesiredOutcome:Fluegasesremovedsafelyandcost-efficiently
Specification(s):Terminationwillbelocatedawayfromwindows,doors,walkways,oranyairintakeopeninginaccordancewithapplicablecodesandmanufacturer'sinstructions
Aestheticsandnoiseshouldbeconsidered
Objective(s):Ensureventterminationdoesnotcreatesafetyhazard
HeatingandCooling>HydronicHeating(HotWaterandSteam)>EquipmentInstallation5.3102.2c-Locationofventingpath
5.3102.2c-LocationofventingpathDesiredOutcome:Fluegasesremovedsafelyandcost-efficiently
Specification(s):Ventingwillberoutedintheshortestandmostdirectpathpossibleinaccordancewithapplicablecodesandmanufacturer'sinstructions
Objective(s):Successfullyremovefluegasesandmoisture
HeatingandCooling>HydronicHeating(HotWaterandSteam)>EquipmentInstallation5.3102.2d-Connectionpoints/joints
5.3102.2d-Connectionpoints/jointsDesiredOutcome:Fluegasesremovedsafelyandcost-efficiently
Specification(s):Ventjointswillbeairtightandwatertightinaccordancewithapplicablecodesandmanufacturer'sinstructions
Objective(s):Ensuresafeoperation
HeatingandCooling>HydronicHeating(HotWaterandSteam)>EquipmentInstallation5.3102.2e-Pitchofflueconnection
5.3102.2e-PitchofflueconnectionDesiredOutcome:Fluegasesremovedsafelyandcost-efficiently
Specification(s):VentwillbepitchedbacktotheboilerforcategoriesI,II,andIII
VentforcategoryIVwillbepitchedinaccordancewithmanufacturerspecifications
Objective(s):Ensureproperdraft
Ensurepropercondensatemanagement
HeatingandCooling>HydronicHeating(HotWaterandSteam)>EquipmentInstallation
5.3102.14-ExpansionTankInstallation(HotWater)DesiredOutcome:Accommodatetheexpansionandcontractionofthesystemfluid
HeatingandCooling>HydronicHeating(HotWaterandSteam)>EquipmentInstallation5.3102.14a-Checkforpresenceofasbestos-containingmaterials(ACMs)
5.3102.14a-Checkforpresenceofasbestos-containingmaterials(ACMs)DesiredOutcome:Accommodatetheexpansionandcontractionofthesystemfluid
Specification(s):PotentialACMswillbehandledinaccordancewithSWS2.0110.2PotentialAsbestos-ContainingMaterials
Objective(s):Ensureasafeworkenvironment
HeatingandCooling>HydronicHeating(HotWaterandSteam)>EquipmentInstallation5.3102.14b-Sizetank
5.3102.14b-SizetankDesiredOutcome:Accommodatetheexpansionandcontractionofthesystemfluid
Specification(s):Locationofexpansiontankandoperationalcharacteristics(systemvolume,operatingtemperaturerange,operatingpressurerange,andfluidtype)willbeusedtodeterminesizeoftank
Objective(s):Selectanappropriatelysizedtank
HeatingandCooling>HydronicHeating(HotWaterandSteam)>EquipmentInstallation5.3102.14c-Isolateinstallationlocation
5.3102.14c-IsolateinstallationlocationDesiredOutcome:Accommodatetheexpansionandcontractionofthesystemfluid
Specification(s):Nearestvalvesoneithersideofinstallationlocationwillbeclosed
Objective(s):Eliminatewatersupplytotheinstallationlocation
HeatingandCooling>HydronicHeating(HotWaterandSteam)>EquipmentInstallation5.3102.14d-Installtank
5.3102.14d-InstalltankDesiredOutcome:Accommodatetheexpansionandcontractionofthesystemfluid
Specification(s):Tankwillbeconnectedtoexistingsystempipinginaccordancewithmanufacturerspecifications
Objective(s):Properlyinstallexpansiontank
HeatingandCooling>HydronicHeating(HotWaterandSteam)>EquipmentInstallation5.3102.14e-Pressurizetank
5.3102.14e-PressurizetankDesiredOutcome:Accommodatetheexpansionandcontractionofthesystemfluid
Specification(s):Expansiontankwillbepressurizedinaccordancewithmanufacturerspecificationstotheappropriatesystemoperatingpressure
Systemwillbefilledandairwillbeeliminated
Objective(s):Pressurizethetanktothestandardoperatingpressure
HeatingandCooling>HydronicHeating(HotWaterandSteam)>EquipmentInstallation5.3102.14f-Reinsulatearea
5.3102.14f-ReinsulateareaDesiredOutcome:Accommodatetheexpansionandcontractionofthesystemfluid
Specification(s):Whereinsulationwasremoved,pipingwillbereinsulatedwithnewinsulationtoIECCandASHRAE90.1,ataminimum
Objective(s):Reduceenergyloss
Maintainsafesurfacetemperature
HeatingandCooling>HydronicHeating(HotWaterandSteam)>EquipmentInstallation5.3102.14g-Education
5.3102.14g-EducationDesiredOutcome:Accommodatetheexpansionandcontractionofthesystemfluid
Specification(s):Completedworkwillbereviewedwiththebuilding/propertymanagementteamandoperationsstaff
Building/propertymanagementteamandoperationsstaffwillbeeducatedonthesafeandefficientoperationandmaintenancerequirementsoftheinstalleditem
Objective(s):Ensurebuilding/propertymanagementteamandoperationsstaffisinformedofthesafe,efficientoperationandmaintenancerequirementsoftheinstalleditem
HeatingandCooling>HydronicHeating(HotWaterandSteam)>EquipmentInstallation
5.3102.15-Bladder-TypeExpansionTankPressurization(HotWater)DesiredOutcome:Allowforaccommodationfortheexpansionandcontractionofthesystemfluid
Note:
HeatingandCooling>HydronicHeating(HotWaterandSteam)>EquipmentInstallation5.3102.15a-Checkforpresenceofasbestos-containingmaterials(ACMs)
5.3102.15a-Checkforpresenceofasbestos-containingmaterials(ACMs)DesiredOutcome:Allowforaccommodationfortheexpansionandcontractionofthesystemfluid
Specification(s):PotentialACMswillbehandledinaccordancewithSWS2.0110.2PotentialAsbestos-ContainingMaterials
Objective(s):Ensureasafeworkenvironment
HeatingandCooling>HydronicHeating(HotWaterandSteam)>EquipmentInstallation5.3102.15b-Isolateexpansiontank
5.3102.15b-IsolateexpansiontankDesiredOutcome:Allowforaccommodationfortheexpansionandcontractionofthesystemfluid
Specification(s):Expansiontankvalvewillbeclosed
Existingwaterwillbedrainedfromexpansiontank
Objective(s):Removesystempressurefromexpansiontankanddraintank
HeatingandCooling>HydronicHeating(HotWaterandSteam)>EquipmentInstallation5.3102.15c-Repressurizetank
5.3102.15c-RepressurizetankDesiredOutcome:Allowforaccommodationfortheexpansionandcontractionofthesystemfluid
Specification(s):Expansiontankwillberepressurizedinaccordancewithmanufacturerspecificationtoappropriatesystemoperatingpressure
Expansiontankbladderwillbereplacedinaccordancewithmanufacturerspecificationsorentiretankwillbereplacedifunabletomaintainrequiredairpressure
Systemwillberefilledandairwillbeeliminated
Objective(s):Pressurizethetanktostandardoperatingpressure
HeatingandCooling>HydronicHeating(HotWaterandSteam)>EquipmentInstallation5.3102.15d-Education
5.3102.15d-EducationDesiredOutcome:Allowforaccommodationfortheexpansionandcontractionofthesystemfluid
Specification(s):Completedworkwillbereviewedwiththebuilding/propertymanagementteamandoperationsstaff
Building/propertymanagementteamandoperationsstaffwillbeeducatedonthesafeandefficientoperationandmaintenancerequirementsoftheinstalleditem
Objective(s):Ensurebuilding/propertymanagementteamandoperationsstaffisinformedofthesafe,efficientoperationandmaintenancerequirementsoftheinstalleditem
HeatingandCooling>HydronicHeating(HotWaterandSteam)>EquipmentInstallation
5.3102.18-FlueGasCondensateTreatment—CondensingDesiredOutcome:Safemanagementoffluegascondensate
Note:
HeatingandCooling>HydronicHeating(HotWaterandSteam)>EquipmentInstallation5.3102.18a-Fluecondensatedrainage
5.3102.18a-FluecondensatedrainageDesiredOutcome:Safemanagementoffluegascondensate
Specification(s):Allpotentialcondensatecollection(low)pointsinthefluesystemwillbeidentifiedandadjustedtoprovideproperpitchasrequiredbythemanufacturer'srequirements
Allcondensatepipingwillbepitchedtowardthedrain(referSWS5.3102.2VentingSealedCombustionAppliance)
Objective(s):Removeallfluegascondensation
Ensurethatallpotentialpointsofcondensationcollectionaredrained
HeatingandCooling>HydronicHeating(HotWaterandSteam)>EquipmentInstallation5.3102.18b-Connection
5.3102.18b-ConnectionDesiredOutcome:Safemanagementoffluegascondensate
Specification(s):Connectionsincondensatedrainsystemwillbewatertight
Objective(s):Ensurecondensatedrainconnectionsdonotleak
HeatingandCooling>HydronicHeating(HotWaterandSteam)>EquipmentInstallation5.3102.18c-Pumps
5.3102.18c-PumpsDesiredOutcome:Safemanagementoffluegascondensate
Specification(s):Whenapprovedbythelocaljurisdiction,condensatedrainpumpswillbeinstalledwhencondensatecannotbedrainedbygravity
Powersourceforpumpwillbeinstalled
Operationanddrainageofpumpwillbeverified
Objective(s):Ensurecondensateproperlydrains
HeatingandCooling>HydronicHeating(HotWaterandSteam)>EquipmentInstallation5.3102.18d-Ventsandtraps
5.3102.18d-VentsandtrapsDesiredOutcome:Safemanagementoffluegascondensate
Specification(s):Ventsandtrapswillbeinstalledoncondensatedrainlines
Trapssuppliedwiththeequipmentwillbeusedinaccordancewithmanufacturerspecifications
Objective(s):Ensurecondensatedrainoperatesasdesigned
Ensurecondensatetrapdoesnotleakair
HeatingandCooling>HydronicHeating(HotWaterandSteam)>EquipmentInstallation5.3102.18e-Termination
5.3102.18e-TerminationDesiredOutcome:Safemanagementoffluegascondensate
Specification(s):Condensatedrainwillbeterminatedinaccordancewithlocalcodes
Objective(s):Ensurecondensatedoesnotleaktothebuilding
Ensurecondensatedraindoesnotfreeze
HeatingandCooling>HydronicHeating(HotWaterandSteam)>EquipmentInstallation5.3102.18f-Floordrains
5.3102.18f-FloordrainsDesiredOutcome:Safemanagementoffluegascondensate
Specification(s):Floordrainswillbeinworkingcondition
Objective(s):Ensureproperdrainageoftheroom
HeatingandCooling>HydronicHeating(HotWaterandSteam)>EquipmentInstallation
5.3102.18g-Neutralizationkit
5.3102.18g-NeutralizationkitDesiredOutcome:Safemanagementoffluegascondensate
Specification(s):Boilermanufacturer-specifiedneutralizationkitwillbeinstalledbetweentheboilerandthedraininaccordancewithmanufacturerspecifications
Propertymanager/occupantwillbeeducatedonpropermaintenance
Objective(s):Neutralizedfluegascondensatebeforeitisdischargedintoadrain
Increasedurabilityofequipment
HeatingandCooling>HydronicHeating(HotWaterandSteam)>EquipmentInstallation5.3102.18h-Pipingmaterial
5.3102.18h-PipingmaterialDesiredOutcome:Safemanagementoffluegascondensate
Specification(s):Pipingmaterial,locatedbetweenboilerandneutralizationkit,willbecapableofwithstandingacidicenvironments
Pipingmaterial,locatedafterneutralizationkitandbeforefloordrain,willbehardpipedtowithstandcrushingandkinking
Objective(s):Ensurelongevityofthepiping
Protectpiping
HeatingandCooling>HydronicHeating(HotWaterandSteam)>EquipmentInstallation5.3102.18i-Education
5.3102.18i-EducationDesiredOutcome:Safemanagementoffluegascondensate
Specification(s):Completedworkwillbereviewedwiththebuilding/propertymanagementteamandoperationsstaff
Building/propertymanagementteamandoperationsstaffwillbeeducatedonthesafeandefficientoperationandmaintenancerequirementsoftheinstalleditem
Objective(s):Ensurebuilding/propertymanagementteamandoperationsstaffisinformedofthesafe,efficientoperationandmaintenancerequirementsoftheinstalleditem
HeatingandCooling>HydronicHeating(HotWaterandSteam)>EquipmentInstallation
5.3102.28-BurnersDesiredOutcome:Efficienciessafelymaximized
HeatingandCooling>HydronicHeating(HotWaterandSteam)>EquipmentInstallation5.3102.28a-Assessment
5.3102.28a-AssessmentDesiredOutcome:Efficienciessafelymaximized
Specification(s):InspectionswillbemadebasedonANSI/ASHRAE/ACCAStandard180StandardPracticeforInspectionandMaintenanceofCommercialBuildingHVACSystemsforcommercialapplicationsandANSI/ACCA4MaintenanceofResidentialHVACSystemsforresidentialapplications
Examplesofitemstobeaddressedareasfollows:
AreviewofsiteconditionsandverificationofefficiencyperformanceconditionofburnershallbeevaluatedSafetyissueswillbeaddressed
Objective(s):Determineifboilerreplacementisneeded
Confirmfeasibilityofthescopeofwork
Improvesafetyandefficiency
HeatingandCooling>HydronicHeating(HotWaterandSteam)>EquipmentInstallation5.3102.28b-Service,upgrade,orreplaceburner
5.3102.28b-Service,upgrade,orreplaceburnerDesiredOutcome:Efficienciessafelymaximized
Specification(s):InspectionswillbemadebasedonANSI/ASHRAE/ACCAStandard180StandardPracticeforInspectionandMaintenanceofCommercialBuildingHVACSystemsforcommercialapplicationsandANSI/ACCA4MaintenanceofResidentialHVACSystemsforresidentialapplications
Examplesofitemstobeaddressedareasfollows:
CombustionairintakedampersFuel/airmodulatingElectronicignitionLinkage-lessfuel/aircontrolOxygentrimVariablefrequencydrivesLownitrogenoxide(replacementburner)Highturndownratioburner
Ifnotpresentorinscopeofwork,aboveupgradeswillbeconsidered
Shortcyclingwillbeeliminated
Objective(s):Improvesafetyandefficiency
Identifyopportunitiesforupgrades
HeatingandCooling>HydronicHeating(HotWaterandSteam)>EquipmentInstallation5.3102.28c-Combustionefficiency
5.3102.28c-CombustionefficiencyDesiredOutcome:Efficienciessafelymaximized
Specification(s):Undilutedfluegaseswillbecheckedwithacalibratedfluegasanalyzerinaccordancewithacceptedprotocol
Ifcombustionisnotoccurringsafelyorwithmaximumefficiency,diagnosticsandadjustmentswillbedoneinaccordancewithworkorderspecifications
Fuel/airratiowillbeadjustedtomeetspecifiedperformanceoverarangeoffiringrates,whenapplicable
Objective(s):Confirmthatcombustionoccurssafelywithmaximumefficiency
HeatingandCooling>HydronicHeating(HotWaterandSteam)>EquipmentInstallation5.3102.28d-Modulation
5.3102.28d-ModulationDesiredOutcome:Efficienciessafelymaximized
Specification(s):Contractorwilldemonstratetheburnermodulatesoverthespecifiedoperatingrange(steampressureandwatertemperature)andfiringrates
Combustionefficiencywillmatchworkorderspecificationsoverspecifiedfiringratesorturndownratios
Objective(s):Engageandoptimizemodulation
HeatingandCooling>HydronicHeating(HotWaterandSteam)>EquipmentInstallation5.3102.28e-Education
5.3102.28e-EducationDesiredOutcome:Efficienciessafelymaximized
Specification(s):Buildingoperationsstaffwillbeeducatedonburnercapabilitiesandongoingmaintenance
Objective(s):Maintainoptimalperformance
HeatingandCooling>HydronicHeating(HotWaterandSteam)>EquipmentInstallation5.3102.28f-Startup
5.3102.28f-StartupDesiredOutcome:Efficienciessafelymaximized
Specification(s):Startupwillbeperformedby"qualifiedperson,"asdefinedinNFPA31,3.3.50
Objective(s):Ensureproperinstallationandsetup
HeatingandCooling>HydronicHeating(HotWaterandSteam)>EquipmentInstallation5.3102.28g-Fuel
5.3102.28g-FuelDesiredOutcome:Efficienciessafelymaximized
Specification(s):Whereapplicable,dualfuelsystemswillberecommendedwhenreplacingoil-firedburners
Dualfuelswitchcontroloperationwillbeconfirmed
Objective(s):Ensurefuelflexibility
HeatingandCooling>HydronicHeating(HotWaterandSteam)>EquipmentInstallation
5.3102.30-Controls—EnergyManagementSystemsDesiredOutcome:InstallEnergyManagementSystems
Note:
HeatingandCooling>HydronicHeating(HotWaterandSteam)>EquipmentInstallation5.3102.30a-Hazardousmaterials
5.3102.30a-HazardousmaterialsDesiredOutcome:InstallEnergyManagementSystems
Specification(s):MaterialscontainingasbestoswillbehandledinaccordancewithSWS2.0110.2PotentialAsbestos-ContainingMaterials
Hazardousmaterialswillbehandledinaccordancewithapplicablelocallawsandcodesbeforeworkbegins
Objective(s):Ensuresafeenvironmentandworkplace
HeatingandCooling>HydronicHeating(HotWaterandSteam)>EquipmentInstallation5.3102.30b-Assessmentandverification
5.3102.30b-AssessmentandverificationDesiredOutcome:InstallEnergyManagementSystems
Specification(s):Verifysiteconditionstoassesswhetherthespecifiedcontrolsystemiscompatiblewiththesystemsitwillmonitorandmanage
Existingelectricalservicewillbeverifiedforadequacy
Ifelectricalserviceisinadequate,theengineerwillbenotifiedandwillonlyproceedaftertheengineer'sapprovalandguidanceofproperactions
Objective(s):Determineifspecifiedcontrolcanbeinstalledatthesiteandisthecorrectcontrolsystemforthesite
HeatingandCooling>HydronicHeating(HotWaterandSteam)>EquipmentInstallation5.3102.30c-Installationofanenergymanagementsystem(EMS)
5.3102.30c-Installationofanenergymanagementsystem(EMS)DesiredOutcome:InstallEnergyManagementSystems
Specification(s):Controlpanelwillbemountedatasafelocationtopreventdamagetothecontrolpanelfromwaterand/orexcessiveheat
Locationwillbeeasilyaccessibleandincloseproximityofthedoor
Atminimum,thefollowingsensorswillbeinstalled(allsensorwiringwillbeinmetalconduit;allconduitswillbesecuredtowallormetalstrutorotheracceptablesurfaces):
OutsideairtemperaturesensorStacktemperatureDomestichotwatersupplywatertemperaturesensorApartmentspacetemperature(minimum25%oftheresidentialunits)BoilerwatertemperaturesensorNewmake-upwatermeterBoilerpressuresensor(steamboileronly)
Outsideairtemperaturesensorwillbeinstalledonthebuildingexterior,10feetabovegrade,4"awayfromthewall,onthenorthfaçade,andinshade;thewallpenetrationmadetoruntheconduitwillbesealedairtightwithfire-ratedmaterialinaccordancewithapplicablecodes;sensorwillbewiredtothecontrolpanel
Additionalsensorsandcontrolpointswillbeinstalledasrequiredbythemanufacturertooptimizesystemoperation
Controlpanelwillbemountedonthewall,andallconnectedsensorswillbewiredtothecontrolpanelinaccordancewithmanufacturerspecifications
Controlpanelwillbeenergized,andallsensorswillbecheckedforproperaccuracyandcommunication
Objective(s):Ensurethecontrolisinstalledtoachieveoptimizedsavingsandcomfort
HeatingandCooling>HydronicHeating(HotWaterandSteam)>EquipmentInstallation5.3102.30d-Testingandverification
5.3102.30d-TestingandverificationDesiredOutcome:InstallEnergyManagementSystems
Specification(s):Controlpanelwillbeexercised,sensorswillbecalibrated,remotecommunicationwillbeconfirmed,alarmswillbesetandtested,andentiresystemwillbecommissioned
Acompleteinstallationandoperationsandmaintenancemanualwillbeprovidedtotheclient
Objective(s):Confirmsystemcapabilitiesandfunctionalities
HeatingandCooling>HydronicHeating(HotWaterandSteam)>EquipmentInstallation5.3102.30e-Education
5.3102.30e-EducationDesiredOutcome:InstallEnergyManagementSystems
Specification(s):Occupantwillbeinvolvedintheinitialprogrammingofthecontrol,controlsetpoints,remotelogin,monitoring,andcontroladjustment,andeducatedoncommonsettingsandprogramming
Objective(s):Educateclientonbestuse
HeatingandCooling>HydronicHeating(HotWaterandSteam)>EquipmentInstallation
5.3102.37-Controls—ThermostatReplacementDesiredOutcome:Thermostatreplacedwhenappropriate
Note:
HeatingandCooling>HydronicHeating(HotWaterandSteam)>EquipmentInstallation5.3102.37a-Visualinspection
5.3102.37a-VisualinspectionDesiredOutcome:Thermostatreplacedwhenappropriate
Specification(s):Thermostatswillbevisuallylocated
Replacementwillberecommendedifadigital,programmablethermostatisnotpresent
(Note:Highmass,radiantsystemsmayormaynotbenefitfromprogrammablethermostats)
Objective(s):Determineifexistingthermostatsneedtobereplaced
HeatingandCooling>HydronicHeating(HotWaterandSteam)>EquipmentInstallation5.3102.37b-Mercuryassessment
5.3102.37b-MercuryassessmentDesiredOutcome:Thermostatreplacedwhenappropriate
Specification(s):ThermostatscontainingmercurywillbeidentifiedanddisposedofinaccordancewithEPAguidance
Objective(s):Protectworkersandoccupantsfrommercuryexposure
HeatingandCooling>HydronicHeating(HotWaterandSteam)>EquipmentInstallation5.3102.37c-Installation
5.3102.37c-InstallationDesiredOutcome:Thermostatreplacedwhenappropriate
Specification(s):Locationfornewthermostatwillbedeterminedinaccordancewithapplicablecodesandmanufacturer'sinstructions
ThenewthermostatwillbelocatedsuchthatitiseasilyaccessibleforcontrolwithoutanyneedforstepstoolorladdertocomplywithFederalFairHousingAct
Compatibilityoftheexistingsystemwithnewthermostatwillbeverified(e.g.,voltage,wiring,condition,location)
Newthermostatwillbeinstalled
Objective(s):Achievecomfortandenergysavingsfortheoccupant
HeatingandCooling>HydronicHeating(HotWaterandSteam)>EquipmentInstallation5.3102.37d-Testing
5.3102.37d-TestingDesiredOutcome:Thermostatreplacedwhenappropriate
Specification(s):Heatingsystemwillbere-energizedandcycled
Thermostatwillbeprogrammedtooccupant'slifestylechoices
Objective(s):Ensuresafeandefficientoperation
HeatingandCooling>HydronicHeating(HotWaterandSteam)>EquipmentInstallation5.3102.37e-Disposal
5.3102.37e-DisposalDesiredOutcome:Thermostatreplacedwhenappropriate
Specification(s):RemovedthermostatswillbedisposedofinaccordancewithEPAguidelines
Objective(s):Preventmercuryfromenteringtheenvironment
HeatingandCooling>HydronicHeating(HotWaterandSteam)>EquipmentInstallation5.3102.37f-Education
5.3102.37f-EducationDesiredOutcome:Thermostatreplacedwhenappropriate
Specification(s):Building/propertymanagementteamandoperationsstaffandoccupantswillbeinvolvedintheinitialprogrammingofthermostatandeducatedoncommonsettingsandprogramming
Onnewinstalls,building/propertymanagementteamandoperationsstaffandoccupantswillbeencouragedtosavethemanualandkeepitaccessible
Objective(s):Educatebuilding/propertymanagementteamandoperationsstaffandoccupantonbestuse
HeatingandCooling>HydronicHeating(HotWaterandSteam)>EquipmentInstallation
5.3102.38-FullCommissioningDesiredOutcome:Controlqualityandoptimizeperformanceandsafety
Note:
HeatingandCooling>HydronicHeating(HotWaterandSteam)>EquipmentInstallation5.3102.38a-Commissioningteam
5.3102.38a-CommissioningteamDesiredOutcome:Controlqualityandoptimizeperformanceandsafety
Specification(s):Whenfullcommissioningiswarranted,thecommissioningteamwillbeidentified,andincludecommissioningagent,owner,propertymanager,contractor,engineer,architect,andbuildingoperationsstaff
Scopeofcommissioningwillbeconfirmed
Rolesandresponsibilitieswillbeidentified
Forindividualresidentialorlightcommercialinstallations,documentation,ownereducation,andtrainingwillbeinaccordancewithproceduresinANSI/ACCAStandard5
Objective(s):Assigncommissioningresponsibilities
HeatingandCooling>HydronicHeating(HotWaterandSteam)>EquipmentInstallation5.3102.38b-Designintentandapproach
5.3102.38b-DesignintentandapproachDesiredOutcome:Controlqualityandoptimizeperformanceandsafety
Specification(s):Owner'sprojectrequirementsandbasisofdesignwillbereviewedwithcommissioningteam
Siteassessmentwillbereviewedandverified
Objective(s):Orienttheinstallationcontractortotheintentanddesignoftheproject
Orientthepropertymanagertotheintentanddesignoftheproject
HeatingandCooling>HydronicHeating(HotWaterandSteam)>EquipmentInstallation5.3102.38c-Designreview
5.3102.38c-DesignreviewDesiredOutcome:Controlqualityandoptimizeperformanceandsafety
Specification(s):Controlsequencewillbereviewedwithmanufacturer,installationcontractor,andbuildingoperationsstaff
Workscopeanddesignelementswillbereviewedtoincludeataminimum:
ControlsequenceInstrumentationCoordinationofcontrolsandequipment
Objective(s):Ensurespecifieddesignisoptimalforproject
HeatingandCooling>HydronicHeating(HotWaterandSteam)>EquipmentInstallation5.3102.38d-Submittals
5.3102.38d-SubmittalsDesiredOutcome:Controlqualityandoptimizeperformanceandsafety
Specification(s):Submittalswillbesuppliedtothecommissioningteamforreviewandapproval
Objective(s):Ensurespecifiedmaterialsareincludedfortheproject
HeatingandCooling>HydronicHeating(HotWaterandSteam)>EquipmentInstallation5.3102.38e-Pre-functionalchecklist
5.3102.38e-Pre-functionalchecklistDesiredOutcome:Controlqualityandoptimizeperformanceandsafety
Specification(s):Checklistwillbecreatedandapprovedbycommissioningagent
Checklistwillbecompletedandsubmittedtocommissioningteambyinstallationcontractor
Objective(s):Verifyinstallationandstartup
HeatingandCooling>HydronicHeating(HotWaterandSteam)>EquipmentInstallation5.3102.38f-Functionaltest
5.3102.38f-FunctionaltestDesiredOutcome:Controlqualityandoptimizeperformanceandsafety
Specification(s):Functionaltestprocedurewillbedevelopedandapproved
Functionaltestingwillbeperformedbyacontractorandwitnessedbycommissioningagent
Functionaltestwilldemonstratesequenceofcontrol
Contractorwillcorrectanyfailuresandretest
Objective(s):Ensureequipment/materialsareworkingtogetherinpropersequenceandcoordination
Followspecifiedsequenceofcontrol
HeatingandCooling>HydronicHeating(HotWaterandSteam)>EquipmentInstallation5.3102.38g-Documents
5.3102.38g-DocumentsDesiredOutcome:Controlqualityandoptimizeperformanceandsafety
Specification(s):Operationsandmaintenancemanualwillbecustomizedforprojectbyinstallationcontractor
Operationsandmaintenancemanualwillbesubmittedtocommissioningagentforapproval
Multiplecopiesofoperationsandmaintenancemanualwillbeprovidedtopropertymanager
Commissioningprocessbinderwillbeprovidedtopropertymanagerbycommissioningagent
Objective(s):Providedocumentationforoptimaloperationandmaintenanceofequipment
HeatingandCooling>HydronicHeating(HotWaterandSteam)>EquipmentInstallation5.3102.38h-Education
5.3102.38h-EducationDesiredOutcome:Controlqualityandoptimizeperformanceandsafety
Specification(s):Contractorwillberesponsibleforconducting/providingonsiteeducationtothebuildingoperationsstaffontheoperationandmaintenanceoftheinstalledequipment
Buildingoperationsstaffeducationwillbewitnessedbydesignatedcommissioningteammembers
Objective(s):Educatebuildingoperationsstafftooperateandmaintainthesystemforoptimalperformance
HeatingandCooling>HydronicHeating(HotWaterandSteam)>EquipmentInstallation5.3102.38i-Nearendofwarrantysitevisit
5.3102.38i-NearendofwarrantysitevisitDesiredOutcome:Controlqualityandoptimizeperformanceandsafety
Specification(s):Inspectionwilloccur(approximately9monthsafterinstallorfinalequipmentacceptance)beforethewarrantyends
Contractorwillresolveanyoutstandingissuesbeforewarrantyends
Objective(s):Resolveequipmentissuesbeforewarrantyends
HeatingandCooling>HydronicHeating(HotWaterandSteam)>EquipmentMaintenance,Testing,andRepair
5.3104.12-LeakDetectionandRepair—DistributionLeaksDesiredOutcome:Systemdoesnotleak
HeatingandCooling>HydronicHeating(HotWaterandSteam)>EquipmentMaintenance,Testing,andRepair5.3014.12d-Testingandverification
5.3014.12d-TestingandverificationDesiredOutcome:Systemdoesnotleak
Specification(s):Isolatedsectionwillbereconnectedandrepressurized
Systemwillbefilledandairwillbeeliminatedfromsystem
Repairedpipe,fitting,ordevicewillbevisuallyinspected
Objective(s):Confirmsystemissafeforoperation
HeatingandCooling>Non-DistributionCoolingSystems>RoomAirConditioners
5.3302.1-Through-WallandRoomAirConditioningUnitReplacementDesiredOutcome:Energyusedforairconditioningreduced
Note:
HeatingandCooling>Non-DistributionCoolingSystems>RoomAirConditioners5.3302.1a-Assessment
5.3302.1a-AssessmentDesiredOutcome:Energyusedforairconditioningreduced
Specification(s):Physicalsizeofthrough-wallopeningwillbedetermined
UnitandelectricalreceptaclewillmeetrequirementsofNFPA70Article440
Workorderwillbeevaluatedagainstsitecircumstances
Objective(s):Determineandensureappropriatedeviceandlocation
HeatingandCooling>Non-DistributionCoolingSystems>RoomAirConditioners5.3302.1b-Selection
5.3302.1b-SelectionDesiredOutcome:Energyusedforairconditioningreduced
Specification(s):Unitwillmatchavailablevoltageandnotexceedcurrentavailablevoltageattheexistingelectricaloutlet
Replacementunitwillprovidesameorbetterfunctionalitythanexistingunit,butsmallerdutyunitwillbeprovidedifexistingisoversized
ReplacementunitwillbeENERGYSTAR®qualifiedwithEnergySaverModeorbetter
UnitswithR22refrigerantwillnotbeused
Objective(s):Ensureproperdevicefunction
Avoidaddingadditionalload
Reduceenergyuse
Protecttheenvironment
HeatingandCooling>Non-DistributionCoolingSystems>RoomAirConditioners5.3302.1c-Installation
5.3302.1c-Installation
DesiredOutcome:Energyusedforairconditioningreduced
Specification(s):Extensioncordwillnotbeused(NFPA70Article440)
WhereapplicableunitcontrolsandthermostatshallcomplywiththeoperablepartsprovisionsofICCA117.1whenthedwellingunitisrequiredtobeaccessibleperADA
Unitwillbeself-supportingorpermanentlyinstalled
Perimeterofunitwillbesealedwithadurablematerial(ASTMC1193)
EgresswillbeaddressedtobeinaccordancewithANSI/NFPA101andlocallaws
Objective(s):Ensureintegrityofbuildingenvelope
Ensureoccupantcomfort
Ensureoccupantsafety
Ensurecontinuedsavings
HeatingandCooling>Non-DistributionCoolingSystems>RoomAirConditioners5.3302.1d-Decommissioning
5.3302.1d-DecommissioningDesiredOutcome:Energyusedforairconditioningreduced
Specification(s):Unitsreplacedwillberecycledordisposedofinaccordancewithlocalordinances
RefrigerantwillbehandledinaccordancewithSection608ofCleanAirActof1990andlocalordinances
Objective(s):Preventreuseofinefficientequipmentandcomponents
Protecttheenvironment
HeatingandCooling>Non-DistributionCoolingSystems>RoomAirConditioners5.3302.1e-Staffeducation
5.3302.1e-StaffeducationDesiredOutcome:Energyusedforairconditioningreduced
Specification(s):Buildingoperationsstaffwillbeeducatedonstrategiesforwinterizingcooling-onlyequipment
Windowunitswillberemovedandstoredduringlongperiodsofcoldandsnow
Whenunitisnotinuse,itwillbeclosedandcoveredinaccordancewithEnvelopeWallPenetrationStandardWorkSpecification(SWS,section3.1102.1
Buildingoperationsstaffwillbeprovidedwithwarrantyinformation,operationmanuals,andinstallercontactinformation
Objective(s):
Preventenergyloss
Educatebuildingoperationsstaffaboutoperationandmaintenanceofequipment
Ensurecontinuedsavings
HeatingandCooling>Non-DistributionCoolingSystems>RoomAirConditioners5.3302.1f-Occupanteducation
5.3302.1f-OccupanteducationDesiredOutcome:Energyusedforairconditioningreduced
Specification(s):Occupantswillbeprovidedwithamanualandeducatedofnewunitbenefits
Educationwillbeprovidedbybuildingoperationsstaff
Objective(s):Educateoccupantsaboutnewcontrolsandbenefits
Ensurecontinuedsavings
Ventilation>Exhaust>ExhaustVentilationSystems
6.6004.2-IndividualExhaustFanServingMultipleRoomsWithinSingleDwellingUnit(AllBuildingTypes)DesiredOutcome:Multiportfansysteminstalledtoproviderequiredventilation
Note:Theauthorityhavingjurisdictionmayrequirethatalicensedprofessionalperformcertaintasksoutlinedinthisdetail.
Ventilation>Exhaust>ExhaustVentilationSystems6.6004.2a-Pre-inspection
6.6004.2a-Pre-inspectionDesiredOutcome:Multiportfansysteminstalledtoproviderequiredventilation
Specification(s):Specificationswillbefieldverifiedasappropriatetositeconditionsbyinstaller
Objective(s):Ensureappropriatedesignforinstallation
Ventilation>Exhaust>ExhaustVentilationSystems6.6004.2b-Airflow
6.6004.2b-AirflowDesiredOutcome:Multiportfansysteminstalledtoproviderequiredventilation
Specification(s):ASHRAE62.2andlocalcoderequirementsshouldbefollowedforidentifyingdesignairflowrateswithinapartmentdwellingunits.
Allotherareaswillfollowlocalcoderequirementsand/orASHRAE62.1requirements
AirflowswillbemeasuredinaccordancewithANSI/ACCAStandard5orANSI/ASHRAEStandard111andadjustedtomeetdesignrequirements
Objective(s):Exhaustsufficientairfromdesiredlocationstotheoutdoors
Ventilation>Exhaust>ExhaustVentilationSystems6.6004.2c-Outlettermination
6.6004.2c-OutletterminationDesiredOutcome:Multiportfansysteminstalledtoproviderequiredventilation
Specification(s):Outletwillbeterminatedoutsideofthebuildingshellandwillhavealouveredcoverandbirdscreen
Minimumdistanceofexhaustoutletfromanydoors,windows,oroutsideairintakesshallbeinconformancewith
theapplicablebuildingcode
Outletwillbesealedtopreventwaterintrusionandexhaustairleakageintobuildingcavities
Objective(s):Directexhausttotheoutdoorsandpreventre-entry
Prevententryofweatherandpestsintobuildingshell
Ensureoccupanthealthandsafety
Ventilation>Exhaust>ExhaustVentilationSystems6.6004.2d-Wiring
6.6004.2d-WiringDesiredOutcome:Multiportfansysteminstalledtoproviderequiredventilation
Specification(s):Wiringwillbeinstalledbyaproperlylicensedcontractor
Wiringwillbeinstalledinaccordancewithoriginalequipmentmanufacturerspecifications,andlocalandnationalelectricalandmechanicalcodes
RefertoNFPA70:NationalElectricalCodeforinstallationrequirements
Objective(s):Preventanelectricalhazard
Ventilation>Exhaust>ExhaustVentilationSystems6.6004.2e-Access
6.6004.2e-AccessDesiredOutcome:Multiportfansysteminstalledtoproviderequiredventilation
Specification(s):Fanandserviceswitchwillbeaccessibleformaintenance
Objective(s):Ensureunitandserviceswitchareaccessibleformaintenanceorreplacement
Ventilation>Exhaust>ExhaustVentilationSystems6.6004.2f-Fanmounting
6.6004.2f-FanmountingDesiredOutcome:Multiportfansysteminstalledtoproviderequiredventilation
Specification(s):Fanwillbeorientedsotheequivalentlengthoftheductrunisasshortaspossible
Fanwillbemountedsecurelyinaccordancewithmanufacturerspecificationsandlocalcoderequirements(interms
ofseismicrestraints,vibration,andnoisecontrol)
Fanwillbeisolatedfromthebuildingframingunlessspecificallydesignedtobedirectlyattached
Fanwillbeinstalledremotelybyductingfromintakegrilles
Objective(s):Ensureshortductrunstoachieveoptimumairflows
Ensuremountingisinstalledsecurely
Ensurefanhousingorbuildingframingdoesnotshake,rattle,orhumwhenoperating
Minimizenoise
Ventilation>Exhaust>ExhaustVentilationSystems6.6004.2g-Backdraftdampers(requiredinintermittentsystems)
6.6004.2g-Backdraftdampers(requiredinintermittentsystems)DesiredOutcome:Multiportfansysteminstalledtoproviderequiredventilation
Specification(s):Abackdraftdamperwillbeinstalledbetweenthefanandtheexterior
Abackdraftdamperwillbeinstalledinanyductservinganyroomwithaseparateexhaust(e.g.,dryer)
Objective(s):Preventreverseairflowwhenthesystemisoff
Preventspreadofcontaminantsbetweenrooms
Ventilation>Exhaust>ExhaustVentilationSystems6.6004.2h-Combiningintakeducts
6.6004.2h-CombiningintakeductsDesiredOutcome:Multiportfansysteminstalledtoproviderequiredventilation
Specification(s):Allindividualintakeductswillbecombinedontheintakesideoffan(e.g.,Y-fitting,T-fitting,collectorbox)
Objective(s):Exhaustairfromdesiredlocationstotheoutdoors
Ventilation>Exhaust>ExhaustVentilationSystems6.6004.2i-Ductconnections
6.6004.2i-DuctconnectionsDesiredOutcome:Multiportfansysteminstalledtoproviderequiredventilation
Specification(s):Ductswillbeconnectedandsealedtoapplicableintakes,collectorbox,fan,andterminationfitting
Ductswillbeconnectedandsealedinaccordancewiththeapplicablecodeadoptedbythejurisdiction
Objective(s):Exhaustairfromdesiredlocationstotheoutdoors
Preserveintegrityoftheductsystemandbuildingenvelope
Ventilation>Exhaust>ExhaustVentilationSystems6.6004.2j-Insulation
6.6004.2j-InsulationDesiredOutcome:Multiportfansysteminstalledtoproviderequiredventilation
Specification(s):AllcomponentsoutsideofthethermalenvelopewillbeinsulatedtoaminimumofR-8orequivalenttolocalcodes
Objective(s):Preserveintegrityoftheductsystem
Preventcondensationinductwork
Preventheatloss
Ventilation>Exhaust>ExhaustVentilationSystems6.6004.2k-Boottointeriorsurfaceseal
6.6004.2k-BoottointeriorsurfacesealDesiredOutcome:Multiportfansysteminstalledtoproviderequiredventilation
Specification(s):Registerbootwillbesealedtointeriorsurfaceswithsealantscompatibletotheirintendedsurfaces
Sealantswillbecontinuousandmeetfirebarrierspecifications
Bootswillbeconnectedandsealedinaccordancewiththeapplicablecodeadoptedbythejurisdiction
Objective(s):Preventairleakagearoundboot
Ensureapermanentsealtothebuildingairbarrier
Preventafirehazard
Ventilation>Exhaust>ExhaustVentilationSystems6.6004.2l-Preventingairleakagecausedbyexhaustfans
6.6004.2l-PreventingairleakagecausedbyexhaustfansDesiredOutcome:Multiportfansysteminstalledtoproviderequiredventilation
Specification(s):Walls,ceilings,andfloorswillbesealedtoseparateanyoccupiedspacefromanyunconditionedspacesand
adjacentdwellingunits
RefertoASHRAE62.2Section6.1
Objective(s):Ensureoccupanthealthandsafety
Preventairleakageintothebuildingfromotherspaces(e.g.,adjacentdwellingunits,garages,unconditionedcrawlspaces,unconditionedattics)
Ventilation>Exhaust>ExhaustVentilationSystems6.6004.2m-Balanceandflow
6.6004.2m-BalanceandflowDesiredOutcome:Multiportfansysteminstalledtoproviderequiredventilation
Specification(s):Airflowswillbemeasuredandadjustedtomatchtothedesignspecification
Objective(s):Achievethedesiredairflowstoandfromthedesiredlocations
Ventilation>Exhaust>ExhaustVentilationSystems6.6004.2n-Combustionzonetesting
6.6004.2n-CombustionzonetestingDesiredOutcome:Multiportfansysteminstalledtoproviderequiredventilation
Specification(s):Pressureeffectscausedbyfanswillbeassessedandcorrectedwhenfoundoutsideofcombustionsafetystandards
Objective(s):Ensuresafeoperationofcombustionappliances
Ventilation>Exhaust>ExhaustVentilationSystems6.6004.2o-Firedampers
6.6004.2o-FiredampersDesiredOutcome:Multiportfansysteminstalledtoproviderequiredventilation
Specification(s):Firedampersmustbeaccessibleforinspectionand/ortestingbythelocalauthorities;iffiredampersarenotaccessiblefromagrillorregister,anaccessdoorintheductworkisrequired
Sealingactivitieswillnotinterferewiththeoperationoffiredampers,balancingdampers,orbackdraftdampers
TypeBfiredamperswillbeusedasrequiredbyfirecode
Objective(s):
Ensureaccesstofiredampersforsafeoperation
Minimizestaticpressure
Maximizeairflow
Ventilation>Exhaust>ExhaustVentilationSystems6.6004.2p-Occupant/propertymanagereducation
6.6004.2p-Occupant/propertymanagereducationDesiredOutcome:Multiportfansysteminstalledtoproviderequiredventilation
Specification(s):Occupant/propertymanagerwillbeeducatedonpurposeandvalueofsystem
Propertymanagerwillbeinstructedonallmaintenanceprocedures
Objective(s):Ensureoccupanthealthandsafety
Preserveintegrityofsystem
Ventilation>Exhaust>ApplianceExhaustVents
6.6005.4-KitchenRangeHoodwithinDwellingUnit(AllBuildingTypes)DesiredOutcome:Kitchenrangefaninstalledtospecification
Note:Theauthorityhavingjurisdictionmayrequirethatalicensedprofessionalperformcertaintasksoutlinedinthisdetail.
Ventilation>Exhaust>ApplianceExhaustVents6.6005.4a-Pre-inspection
6.6005.4a-Pre-inspectionDesiredOutcome:Kitchenrangefaninstalledtospecification
Specification(s):Specificationswillbefieldverifiedasappropriatetositeconditionsbyinstaller
Objective(s):Ensureappropriatedesignforinstallation
Ventilation>Exhaust>ApplianceExhaustVents6.6005.4b-Wiring
6.6005.4b-WiringDesiredOutcome:Kitchenrangefaninstalledtospecification
Specification(s):Wiringwillbeinstalledbyaproperlylicensedcontractor
Wiringwillbeinstalledinaccordancewithoriginalequipmentmanufacturerspecifications,andlocalandnationalelectricalandmechanicalcodes
RefertoNFPA70:NationalElectricalCodeforinstallationrequirements
Objective(s):Preventanelectricalhazard
Ventilation>Exhaust>ApplianceExhaustVents6.6005.4c-Fanselection/specification
6.6005.4c-Fanselection/specificationDesiredOutcome:Kitchenrangefaninstalledtospecification
Specification(s):FansinstalledinrangehoodsovercookingapplianceswillbedesignedperHomeVentilationInstitute2100specifications
Airflowratewillbeaminimumof100cubicfeetperminute(CFM)
Objective(s):Provideadequateventilationtoremoveodorsandcontaminants
Ventilation>Exhaust>ApplianceExhaustVents6.6005.4d-Fanventing
6.6005.4d-FanventingDesiredOutcome:Kitchenrangefaninstalledtospecification
Specification(s):Kitchenrangefanswillbeventeddirectlytotheoutside
Recirculatingfanswillnotbeusedasaventilatingdevice
Objective(s):Removeodorsandcookingcontaminantsfromthebuilding
Preserveintegrityofbuildingenvelope
Ventilation>Exhaust>ApplianceExhaustVents6.6005.4e-Fanducting
6.6005.4e-FanductingDesiredOutcome:Kitchenrangefaninstalledtospecification
Specification(s):Kitchenrangefanswillbeducteddirectlytotheoutdoors
Asshortarunaspracticalofsmoothwallmetalductwillbeused,followingmanufacturerspecificationsandIMC2009505
DuctingwillbeconnectedandsealedasdescribedinexhaustductdetailsSWS6.6004.1Central/CommonExhaustFanServingMultipleDwellingUnitsviaCommonDuct(s)andDwellingUnitBrancesandSWS6.6004.2IndividualExhaustFanServingMultipleRoomsWithinaSingleDwellingUnit(All3BuildingTypes)
Objective(s):Preserveintegrityofbuildingenvelope
Effectivelymoveairfromrangetotheoutdoors
Ventilation>Exhaust>ApplianceExhaustVents6.6005.4f-Terminationfitting
6.6005.4f-TerminationfittingDesiredOutcome:Kitchenrangefaninstalledtospecification
Specification(s):Terminationfittingwillbeinstalled,includingabackdraftdamper,asdescribedinterminationfittingdetail
Outletwillbeterminatedoutsideofthebuildingshellandwillhavealouveredcoverandbirdscreen
MinimumdistanceofexhaustoutletsinstallednewfromanydoorsoroperablewindowsoroutsideairintakeswillmeetlocalcoderequirementsorspecificationsofASHRAE62.1Table5-1requirements
Outletwillbesealedtopreventwaterandairintrusion
Objective(s):Ensuresafeoperationofcombustionappliances
Ensureoccupanthealthandsafety
Directexhausttotheoutdoorsandpreventre-entry
Prevententryofweatherandpestsintobuildingshell
Ventilation>Exhaust>ApplianceExhaustVents6.6005.4g-Makeupair
6.6005.4g-MakeupairDesiredOutcome:Kitchenrangefaninstalledtospecification
Specification(s):Makeupairwillbeprovidedforkitchenrangefansexhaustingmorethan400CFM
Objective(s):Ensuresafeoperationofcombustionappliances
Minimizeairleakagebetweendwellingunits
Ensureoccupanthealthandsafety
Ventilation>Exhaust>ApplianceExhaustVents6.6005.4h-Verification
6.6005.4h-VerificationDesiredOutcome:Kitchenrangefaninstalledtospecification
Specification(s):Exhaustflowrateswillbemeasuredanddocumentedtomeetdesignrequirements
Objective(s):Ensuretheperformanceoftheventilationsystem
Ensureoccupanthealthandsafety
Ventilation>Exhaust>ApplianceExhaustVents6.6005.4i-Combustionzonetesting
6.6005.4i-CombustionzonetestingDesiredOutcome:Kitchenrangefaninstalledtospecification
Specification(s):
Pressureeffectscausedbyfanswillbeassessedandcorrectedwhenfoundoutsideofcombustionsafetystandards
Objective(s):Ensuresafeoperationofcombustionappliances
Ensureoccupanthealthandsafety
Ventilation>Exhaust>ApplianceExhaustVents6.6005.4j-Occupant/propertymanagereducation
6.6005.4j-Occupant/propertymanagereducationDesiredOutcome:Kitchenrangefaninstalledtospecification
Specification(s):Occupant/propertymanagerwillbeinstructedtokeepgreasefiltersandterminationfittingclean
Objective(s):Effectivelymoveairfromkitchenrangetotheoutdoors
Ventilation>Exhaust>SpecialConsiderations
6.6088.1-RegionalClimaticConsiderationsDesiredOutcome:Regionalclimaticvariablesaretakenintoconsideration
Ventilation>Exhaust>SpecialConsiderations6.6088.1a-Verycold
6.6088.1a-VerycoldDesiredOutcome:Regionalclimaticvariablesaretakenintoconsideration
Specification(s):Ventilationterminationswilleitherhavenobackflowdampersorwillusebackflowdampersthatresistfreezing
Soffitventsthatcontainaventilationexhaustterminationwillbesealedwithin6'ofthetermination
Objective(s):Avoidventilationflapperfreezing
Preventexhaustmoisturefromenteringtheattic
Ventilation>Exhaust>SpecialConsiderations6.6088.1b-Cold
6.6088.1b-ColdDesiredOutcome:Regionalclimaticvariablesaretakenintoconsideration
Specification(s):Exhaustventilationwillbeterminatedattheroof,gableend,orwall
Objective(s):Preventexhaustmoisturefromenteringtheattic
Ventilation>Supply>Components
6.6102.6-IntakesDesiredOutcome:Intakeoptimizesairflowwhilelimitingtheentryofinsects,debris,andcontaminants
Note:
Ventilation>Supply>Components6.6102.6a-Holeinbuildingshell
6.6102.6a-HoleinbuildingshellDesiredOutcome:Intakeoptimizesairflowwhilelimitingtheentryofinsects,debris,andcontaminants
Specification(s):Holescuttoaccommodatetheterminalfittingsshouldbenomorethan1/8"largerthanthefittingitself
Objective(s):Ensureaweathertightinstallation
Ventilation>Supply>Components6.6102.6b-Intakefitting
6.6102.6b-IntakefittingDesiredOutcome:Intakeoptimizesairflowwhilelimitingtheentryofinsects,debris,andcontaminants
Specification(s):Intakefittingwillhaveintegratedcollaratleastthesamediameterastheduct
Thefittingwillbeappropriateforregionalweatherconditionsandinstallationlocationonexteriorofbuilding
Objective(s):Effectivelydrawtherequiredvolumeofairfromoutside
Preserveintegrityofthebuildingenvelope
Ensuredurableinstallation
Ventilation>Supply>Components6.6102.6c-Occupanteducation
6.6102.6c-OccupanteducationDesiredOutcome:Intakeoptimizesairflowwhilelimitingtheentryofinsects,debris,andcontaminants
Specification(s):Intakefittingwillbelabeled"ventilationairintake"
Occupantwillbeinstructedtokeepyarddebrisandothercontaminantsclearoftheintake
Objective(s):
Ensureunrestrictedairflow
Ventilation>Supply>Components6.6102.6d-Damper(ifapplicable)
6.6102.6d-Damper(ifapplicable)DesiredOutcome:Intakeoptimizesairflowwhilelimitingtheentryofinsects,debris,andcontaminants
Specification(s):Thedamperwillbeinstalledtoopeninthedirectionofthedesiredflow
Damperwillclosewhensystemisoff
Objective(s):Ensureunrestrictedairflow
Ventilation>Supply>Components6.6102.6e-Connectiontointakefitting
6.6102.6e-ConnectiontointakefittingDesiredOutcome:Intakeoptimizesairflowwhilelimitingtheentryofinsects,debris,andcontaminants
Specification(s):Ducttointakefittingwillbeconnectedandsealedinaccordancewithsupplyductdetail
Ensurefastenersdonotinhibitintakedamperoperation
Objective(s):Preserveintegrityofthebuildingenvelope
Ensureaweathertightanddurableintakeinstallation
Ensureunrestrictedairflow
Ventilation>Supply>Components6.6102.6f-Weatherproofing
6.6102.6f-WeatherproofingDesiredOutcome:Intakeoptimizesairflowwhilelimitingtheentryofinsects,debris,andcontaminants
Specification(s):Exteriorterminationfittingwillbeflashedorweathersealed
Waterwillbedirectedawayfrompenetration
Installationwillnotinhibitdamperoperation
Weatherproofingwillbeinaccordancewithmanufacturerspecifications
Objective(s):Preserveintegrityofthebuildingenvelope
Ensureaweathertightanddurableintakeinstallation
Ensureunrestrictedairflow
Ventilation>Supply>Components6.6102.6g-Pestexclusion
6.6102.6g-PestexclusionDesiredOutcome:Intakeoptimizesairflowwhilelimitingtheentryofinsects,debris,andcontaminants
Specification(s):Screenmaterialnolessthan1/4"andnogreaterthan1/2"holesizeinanydirectionwillbeused
Screenwillbeinstalledsoitdoesnotinhibitintakedamperoperation
Objective(s):Preventpestentry
Ensureunrestrictedairflow
Ventilation>Supply>Components6.6102.6h-Intakelocation
6.6102.6h-IntakelocationDesiredOutcome:Intakeoptimizesairflowwhilelimitingtheentryofinsects,debris,andcontaminants
Specification(s):Intakewillbeinstalledinaccordancewithallapplicablecoderequirementsand/orthemostcurrentversionofASHRAE62.2
Objective(s):Preventcontaminantsfromenteringbuilding
Ensureunrestrictedairflow
Ventilation>WholeBuildingVentilation>Components
6.6202.4-OperationalControlsDesiredOutcome:Fancontrolssupportventilationstrategy
Note:Theauthorityhavingjurisdictionmayrequirethatalicensedprofessionalperformcertaintasksoutlinedinthisdetail.
Ventilation>WholeBuildingVentilation>Components6.6202.4a-Primaryventilationfan
6.6202.4a-PrimaryventilationfanDesiredOutcome:Fancontrolssupportventilationstrategy
Specification(s):Specificationswillbefieldverifiedasappropriatetositeconditionsbyinstaller
Controlswillbeusedthatcanmeetthefollowingconditions:
Runfancontinuouslyorintermittently,dependingupontheintendedscheduleofoperationOperatefantoproducetheintendedflowforeachintendedflowsettingAnyswitchforventilationsystemwillbelabeled
Objective(s):Deliverintendedairexchange
Ensurefancontrolsmeetintendedventilationstrategy
Ventilation>WholeBuildingVentilation>Components6.6202.4b-Spotfan
6.6202.4b-SpotfanDesiredOutcome:Fancontrolssupportventilationstrategy
Specification(s):Controlswillbeusedthatmeetthefollowingconditions:
Runfancontinuouslyorintermittently,dependingontheintendedscheduleofoperationRunfanforintendedtimefortimedoperationOperatefantoproducetheintendedflowforeachintendedflowsetting
Objective(s):Deliverintendedairexchange
Ensurefancontrolsmeetintendedventilationstrategy
Ventilation>WholeBuildingVentilation>Components6.6202.4c-Wiring
6.6202.4c-Wiring
DesiredOutcome:Fancontrolssupportventilationstrategy
Specification(s):Wiringwillbeinstalledbyaproperlylicensedcontractor
Wiringwillbeinstalledinaccordancewithoriginalequipmentmanufacturerspecifications,andlocalandnationalelectricalandmechanicalcodes
RefertoNFPA70:NationalElectricalCodeforinstallationrequirements.
Objective(s):Preventanelectricalhazard
Ensurefancontrolsmeetintendedventilationstrategy
Ventilation>WholeBuildingVentilation>Components6.6202.4d-Occupancysensors/humidistat
6.6202.4d-Occupancysensors/humidistatDesiredOutcome:Fancontrolssupportventilationstrategy
Specification(s):Manualoverridewillbepresentonallcontrols
Occupancysensorand/orhumidistatwillbecalibratedandcommissionedeffectively,andonamaintenanceschedule
Manufacturerspecificationswillbefollowed
Objective(s):Allowoccupantcontrol
Ensurefancontrolsmeetintendedventilationstrategy
Maintainperformanceofcontroldevice
Ventilation>WholeBuildingVentilation>Components6.6202.4e-Carbondioxidesensors(demandcontrol)
6.6202.4e-Carbondioxidesensors(demandcontrol)DesiredOutcome:Fancontrolssupportventilationstrategy
Specification(s):Multispeedorvariablefrequencydrivefanwillberequired
Sensorswillbecalibratedandcommissionedeffectively,andonamaintenanceschedule
Manufacturerspecificationswillbefollowed
Objective(s):Ensurefancontrolsmeetintendedventilationstrategy
Maintainperformanceofcontroldevice
Ventilation>WholeBuildingVentilation>Components6.6202.4f-Occupant/propertymanagereducation
6.6202.4f-Occupant/propertymanagereducationDesiredOutcome:Fancontrolssupportventilationstrategy
Specification(s):Whenfancontrolsarepresentandcontrolledbyoccupant,asystemoperationguidedesignedforoccupants(nonprofessionals)willbeprovidedtoexplainhowandwhytooperatesystem
Everysixmonths,maintenancestaffwillverifytimersystemsareinplaceandareoperatingproperly
Objective(s):Educateoccupantsaboutsystemoperationandimportance
Deliverintendedairexchange
Baseload>PlugLoad>Refrigerators/Freezers
7.8001.3-RefrigeratorandFreezerReplacementDesiredOutcome:Energyefficientapplianceinstalled
Note:
Baseload>PlugLoad>Refrigerators/Freezers7.8001.3a-Assessment
7.8001.3a-AssessmentDesiredOutcome:Energyefficientapplianceinstalled
Specification(s):UnitandelectricalreceptaclewillmeetrequirementsofNFPA70Article440
Objective(s):Determineandensureappropriatedeviceandlocation
Baseload>PlugLoad>Refrigerators/Freezers7.8001.3b-Selection
7.8001.3b-SelectionDesiredOutcome:Energyefficientapplianceinstalled
Specification(s):ApplianceshallbeENERGYSTAR®rated
Appliancewillfitintheavailablespacewithoutblockingaccesstolightswitches,cabinets,etc.
Appliancewillcarryaminimum1-yearwarranty,whichwillprovideareplacementapplianceifrepeatedissuesrelatingtohealth,safety,orperformanceoccur
Objective(s):Reduceenergyuse
Ensuredevicefunctionsproperly
Ensureproductsafety
Ensureoccupantsatisfaction
Baseload>PlugLoad>Refrigerators/Freezers7.8001.3c-Installation
7.8001.3c-InstallationDesiredOutcome:Energyefficientapplianceinstalled
Specification(s):
Appliancewillbeinstalledinaccordancewithmanufacturerspecificationsandlocalcodes
Whereapplicable,applianceshallbeaccessibletothedisabledasrequiredbytheFederalFairHousingActandICCA117.1;theapplianceshallnotreducerequiredmaneuveringclearancesinthekitchentolessthanthatpermittedbytheAHJ
Anypenetrationstotheexteriorcreatedbytheinstallationoftheappliancewillbesealed
Specificinformationonthepropermaintenanceoftheequipmentwillbeprovidedtotheoccupant
Warrantyinformation,operationmanuals,andinstallercontactinformationwillbeprovidedtotheoccupant
Objective(s):Ensureworkersafety
Ensureoccupantsafety
Ensurecontinuedsavings
Achieveintendedappliancefunction
Preservefoodatlowenergyuse
Baseload>PlugLoad>Refrigerators/Freezers7.8001.3d-Commissioning
7.8001.3d-CommissioningDesiredOutcome:Energyefficientapplianceinstalled
Specification(s):Confirmapplianceisoperatinginaccordancewithmanufacturerspecificationsindicatedinoperationandmaintenancemanuals
Objective(s):Ensureoccupantsatisfaction
Ensureoccupantsafety
Baseload>PlugLoad>Refrigerators/Freezers7.8001.3e-Decommissioning
7.8001.3e-DecommissioningDesiredOutcome:Energyefficientapplianceinstalled
Specification(s):Appliancesreplacedbynewunitswillberecycledordisposedofproperly
Appliancesinfestedwithpestswillbeenclosedbeforemoving
Objective(s):Protecttheenvironment
Preventthereuseofinefficientcomponents
Baseload>PlugLoad>Refrigerators/Freezers7.8001.3f-Safety
7.8001.3f-SafetyDesiredOutcome:Energyefficientapplianceinstalled
Specification(s):AllOSHAstandardpracticeswillbefollowed
Objective(s):Ensureworkersafety
Ensureoccupantsafety
Baseload>PlugLoad>Refrigerators/Freezers7.8001.3g-Staffeducation
7.8001.3g-StaffeducationDesiredOutcome:Energyefficientapplianceinstalled
Specification(s):Warrantyinformation,operationmanuals,andinstallercontactinformationwillbeprovidedtobuildingoperationsstaff
Objective(s):Educatebuildingoperationsstaffaboutoperationandmaintenanceofequipment
Ensurecontinuedsavings
Baseload>PlugLoad>Refrigerators/Freezers7.8001.3h-Occupanteducation
7.8001.3h-OccupanteducationDesiredOutcome:Energyefficientapplianceinstalled
Specification(s):Specificinformationonthepropermaintenanceoftheequipmentwillbeprovidedtotheoccupant
Objective(s):Educateoccupantsaboutapplianceandbenefits
Ensurecontinuedsavings
Baseload>PlugLoad>Lighting
7.8003.11-LampReplacementDesiredOutcome:Energyusedforlightingreduced
Baseload>PlugLoad>Lighting7.8003.11a-Assessment
7.8003.11a-AssessmentDesiredOutcome:Energyusedforlightingreduced
Specification(s):Lightingstrategywillbeprovidedbylightingprofessional
Workorderwillbeevaluatedagainstsitecircumstances
Objective(s):Determineandensureappropriatedeviceandlocation
Baseload>PlugLoad>Lighting7.8003.11b-Selection
7.8003.11b-SelectionDesiredOutcome:Energyusedforlightingreduced
Specification(s):Lampswillbecompatiblewithexistingfixtures
Lampswillmeettheappropriatenationallyrecognizedproductstandard(UL542,UL1570)
OutdoorlampswillbesuitableforlocalclimateconditionsandinaccordancewithANSI/ULproductstandards
ScrewbaselampreplacementswillbeENERGYSTAR®qualifiedoratleastasenergyefficient
CompactfluorescentlampsandlightemittingdiodelampswillbeENERGYSTARqualifiedoratleaseasenergyefficient
LinearfluorescentlampswillnotbereplacedwithaT12,andT8lampswillbeminimumstandardinstalled
Vandal-proofpin-basedlampswillbeused,ifappropriate
Objective(s):Reduceenergyuse
Ensuredevicefunctionsproperly
Ensureproductsafety
Ensureoccupantsatisfaction
Baseload>PlugLoad>Lighting
7.8003.11c-Installation
7.8003.11c-InstallationDesiredOutcome:Energyusedforlightingreduced
Specification(s):Fixturewillbede-energizedbeforebeginningwork
WorkerwillfollowappropriatelockoutproceduresinaccordancewithOSHA1910SubpartSandANSI/NFPA70E
Lampswillbeinstalledinaccordancewithmanufacturerspecifications
Iffixtureisbroken,workerwillrefertoSWS7.8003.14FixtureReplacement
Lensandreflectorwillbecleaned
Objective(s):Ensureworkersafety
Ensureoccupantsafety
Ensurecontinuedsavings
Optimizefixtureperformance
Baseload>PlugLoad>Lighting7.8003.11d-Commissioning
7.8003.11d-CommissioningDesiredOutcome:Energyusedforlightingreduced
Specification(s):RelampingwillbetestedtomeetIESNAprotocolforappropriatelightlevelsforcertaintasksandemergencylevels,asrequiredbytheapplicablecode
Lampswillnotimpactrequiredegresslighting,asrequiredbyANSI/NFPA101
Objective(s):Meettargetlightlevels
Ensureoccupantsatisfaction
Ensureoccupantsafety
Baseload>PlugLoad>Lighting7.8003.11e-Decommissioning
7.8003.11e-DecommissioningDesiredOutcome:Energyusedforlightingreduced
Specification(s):LampswillbedisposedofinaccordancewithEPAguidelines,localordinances,ormanufacturerspecifications
Objective(s):Protecttheenvironment
Preventthereuseofinefficientcomponents
Baseload>PlugLoad>Lighting7.8003.11f-Safety
7.8003.11f-SafetyDesiredOutcome:Energyusedforlightingreduced
Specification(s):BrokenlampscontainingmercurywillbecleanedinaccordancewithEPAguidelines
Objective(s):Ensureworkersafety
Ensureoccupantsafety
Baseload>PlugLoad>Lighting7.8003.11g-Staffeducation
7.8003.11g-StaffeducationDesiredOutcome:Energyusedforlightingreduced
Specification(s):Buildingoperationsstaffwillbeprovidedwithwarrantyinformation,productspecification,andinstallercontactinformation
Objective(s):Educatebuildingoperationsstaffaboutoperationandmaintenanceofequipment
Ensurecontinuedsavings
Baseload>PlugLoad>Lighting7.8003.11h-Occupanteducation
7.8003.11h-OccupanteducationDesiredOutcome:Energyusedforlightingreduced
Specification(s):Occupantswillbeeducatedofnewlamptypeandbenefits
Occupantwillbeprovidedwithlampdisposalprocedure,asdeterminedbybuildingoperationsstaff
Iflampscontainingmercuryareused,occupantswillbeprovidedwithlampdisposalprocedureinaccordancewithEPAguidelines
Educationwillbeprovidedbybuildingoperationsstaff
Objective(s):Educateoccupantsaboutnewlampsandbenefits
Ensurecontinuedsavings
Protecttheenvironment
Ensureoccupantsafety
Baseload>WaterHeating>WaterUseReduction
7.8101.2-Low-FlowRetrofitDevicesDesiredOutcome:Safeandreliablehotwaterdeliverysystemthatmeetstheneedsoftheoccupant/buildingmanagement/buildingoperationsstaffatthelowestpossiblelife-cyclecost
Baseload>WaterHeating>WaterUseReduction7.8101.2a-Removal
7.8101.2a-RemovalDesiredOutcome:Safeandreliablehotwaterdeliverysystemthatmeetstheneedsoftheoccupant/buildingmanagement/buildingoperationsstaffatthelowestpossiblelife-cyclecost
Specification(s):Workareawillbedry
Carewillbetakennottodamageexistingplumbingfixtures,finishes,andsurroundings
Unusualpressureconditionswillbenotedandcommunicatedtopropertymanager(e.g.,high,low,fluctuating)
Existingshowerheadoraeratorwillberemoved
Objective(s):Ensureworkareaissafe
Preventwaterdamagetolivingunit
Baseload>WaterHeating>WaterUseReduction7.8101.2b-Installation
7.8101.2b-InstallationDesiredOutcome:Safeandreliablehotwaterdeliverysystemthatmeetstheneedsoftheoccupant/buildingmanagement/buildingoperationsstaffatthelowestpossiblelife-cyclecost
Specification(s):Low-flowshowerheadsoraeratorswillbeinstalledusinganon-hardeningthreadsealant
Temperature-protectedshutoffvalveswillbeused
Showerheadswithshutoffvalveswillnotbeinstalledinbuildingswithcentralwaterheatingsystems
Objective(s):Ensuresafeandqualityinstallation
Eliminatecrossover
Baseload>WaterHeating>WaterUseReduction7.8101.2c-Commissioning
7.8101.2c-Commissioning
DesiredOutcome:Safeandreliablehotwaterdeliverysystemthatmeetstheneedsoftheoccupant/buildingmanagement/buildingoperationsstaffatthelowestpossiblelife-cyclecost
Specification(s):Properfunctionatthefixturewillbeverifiedbyturningwaterontofullflow
Notificationshouldbegiventotenantsinformingthemnottoremovelowflowshowerheadstomaintainenergyefficiency
Objective(s):Verifythenewend-usedeviceisoperatingproperly
Baseload>WaterHeating>InstallationandReplacement
7.8102.4-StorageTank-TypeWaterHeaterDesiredOutcome:Safeandreliablehotwatersourceprovidedthatmeetsoccupantneedsatlowestpossiblecostofownership
Baseload>WaterHeating>InstallationandReplacement7.8102.4a-Hazardousmaterialremoval
7.8102.4a-HazardousmaterialremovalDesiredOutcome:Safeandreliablehotwatersourceprovidedthatmeetsoccupantneedsatlowestpossiblecostofownership
Specification(s):Healthconcernsintheremovalandreplacementofequipment(e.g.,asbestos,otherhazardousmaterials)willbeidentified
Writtennotificationwillbeprovidedtooccupantsofthediscoveryofhazardousmaterial,includingcontactinformationforregionalEPAasbestoscoordinator
OccupantwillbeaskedtocontractwithanEPA-certifiedasbestoscontractortoconductabatementbeforedecommissioningandreplacement(occupantisresponsibleforabatementorremediation)
Objective(s):RemediatehealthhazardsusingEPA-certifiedcontractors
Baseload>WaterHeating>InstallationandReplacement7.8102.4b-Decommissioning
7.8102.4b-DecommissioningDesiredOutcome:Safeandreliablehotwatersourceprovidedthatmeetsoccupantneedsatlowestpossiblecostofownership
Specification(s):Acceptedindustryproceduresandpracticeswillbefollowedto:
RemoveoldwaterheaterandassociatedcomponentsSealanyunusedchimneyopeningsRemoveunusedoiltank,lines,valves,andassociatedequipment
Objective(s):Ensureworkerandoccupantsafety
Preserveintegrityofthebuilding
Removeoldequipmentinatimelyandefficientmanner
Baseload>WaterHeating>InstallationandReplacement7.8102.4c-Newequipmentinstallation
7.8102.4c-NewequipmentinstallationDesiredOutcome:
Safeandreliablehotwatersourceprovidedthatmeetsoccupantneedsatlowestpossiblecostofownership
Specification(s):Newwaterheaterandassociatedcomponentswillbeinstalledinaccordancewithlocalcodes,acceptedindustrystandardsandpractices,andmanufacturerspecifications
Thesystemwillbeinstalledtobefreezeresistant
Anyexistingwaterleakswillberepairedbeforeinstallationbegins
Anypenetrationstotheexteriorofthehomecreatedbytheinstallationoftheequipmentwillbesealed
Whereearthquakeloadsareapplicable,supportsshallbedesignedandinstalledforseismicforces
Ininstanceswhereconflictsoccurbetweenthecodeandthemanufacturer'sinstallationinstructions,themorerestrictiveprovisionsshallapply
Objective(s):Ensureworkerandoccupantsafety
Preserveintegrityofthebuilding
Removeoldequipmentinatimelyandefficientmanner
Baseload>WaterHeating>InstallationandReplacement7.8102.4d-Emergencydrainpan
7.8102.4d-EmergencydrainpanDesiredOutcome:Safeandreliablehotwatersourceprovidedthatmeetsoccupantneedsatlowestpossiblecostofownership
Specification(s):Anemergencydrainpanwithaminimumdepthof11/2"andsufficientsizeandshapetoreceivealldrippingorcondensateifleakagewouldcausedamagetothespaceshouldbeinstalled.
A3/4"drainlineorlargerwillbeconnectedtotappingonpanandruntoanindirectdrainorpumpedtodaylight
Objective(s):Collectandsafelydisposeofwaterescapingfromthestoragetank
Baseload>WaterHeating>InstallationandReplacement7.8102.4e-Expansiontank
7.8102.4e-ExpansiontankDesiredOutcome:Safeandreliablehotwatersourceprovidedthatmeetsoccupantneedsatlowestpossiblecostofownership
Specification(s):Astainlesssteelbladderexpansiontankwillbeinstalledonthecoldwaterside
Expansiontankshallbeinstalledinaccordancewiththemanufacturer'sinstallationinstructions
Adirectconnectionwithnovalvesbetweenthestoragetankandexpansiontankwillbeinstalled
Objective(s):Protectthestoragetankfromexpansion
Baseload>WaterHeating>InstallationandReplacement7.8102.4f-Temperatureandpressurereliefvalve
7.8102.4f-TemperatureandpressurereliefvalveDesiredOutcome:Safeandreliablehotwatersourceprovidedthatmeetsoccupantneedsatlowestpossiblecostofownership
Specification(s):Correcttemperatureandpressurereliefvalvewillbeinstalledinaccordancewithmanufacturerspecifications
Temperatureandpressurereliefvalvedischargetubewillterminatewithin6"ofthefloor,orasprescribedbylocalcode
Objective(s):Dischargeexcessiveenergy(pressureortemperature)fromstoragetanktosafelocation
Baseload>WaterHeating>InstallationandReplacement7.8102.4g-Dielectricunions(dielectricinsulator)
7.8102.4g-Dielectricunions(dielectricinsulator)DesiredOutcome:Safeandreliablehotwatersourceprovidedthatmeetsoccupantneedsatlowestpossiblecostofownership
Specification(s):Dielectricunions(dielectricinsulator)willbeinstalledinaccordancewithmanufacturerspecifications
Objective(s):Breakthestrayvoltageelectricalcircuitthroughthestoragetank
Baseload>WaterHeating>InstallationandReplacement7.8102.4h-Backflowprevention
7.8102.4h-BackflowpreventionDesiredOutcome:Safeandreliablehotwatersourceprovidedthatmeetsoccupantneedsatlowestpossiblecostofownership
Specification(s):Backflowpreventionwillbeinstalledinaccordancewithmanufacturerspecificationsandallapplicablecodes
Backflowdevicesshallbetestedbyacertifiedbackflowassemblytesteratthetimeofinstallation,repair,orrelocation.
Objective(s):Protectwatersupplyfromcontamination
Baseload>WaterHeating>InstallationandReplacement7.8102.4i-Thermalefficiencyandinsulation
7.8102.4i-ThermalefficiencyandinsulationDesiredOutcome:Safeandreliablehotwatersourceprovidedthatmeetsoccupantneedsatlowestpossiblecostofownership
Specification(s):Ifadditionaltankinsulationisinstalled,itwillberatedaminimumofR-11andinstalledtomanufacturerspecifications
Ifadditionalinsulationisinstalled,itwillbeinstalledbasedonfueltype,makingsurenottoobstructdraftdiverter,pressurereliefvalve,thermostats,hi-limitswitch,plumbingpipesorelements,andthermostataccessplates
Thefirst6'ofinletandoutletpipingwillbeinsulatedinaccordancewithmanufacturerspecifications
Pipeinsulationmustremain3"fromgaswaterheatervent
Heattrapswillbeinstalledontheinletandoutletpipingwherenotprovidedbymanufacturer
Objective(s):Reducestandbylossfromneartankpipingandstoragetank
Ensureinsulationdoesnotmakecontactwithfluegasventing
NMvariancestates:
"Installwaterheaterstoragetankinsulationblanket,minimumvalueofR-11,unlesstheSIRtoaddinsulationislessthan1.0,themanufacturerofthewaterheaterforbidsinstallationofadditionalinsulationorspacelimitationsdonotallow.Addedinsulationwillnotobstructtheunit'sdraftdiverter,pressurereliefvalve,thermostats,hi-limitswitch,plumbingpipesorelements,andthermostataccessplates.Thefirst6'ofinletandoutletpipingwillbeinsulatedinaccordancewithIRCorlocalrequirements,whicheverisgreater."
Baseload>WaterHeating>InstallationandReplacement7.8102.4j-Requiredcombustionair
7.8102.4j-RequiredcombustionairDesiredOutcome:Safeandreliablehotwatersourceprovidedthatmeetsoccupantneedsatlowestpossiblecostofownership
Specification(s):Combustionairshallbecalculatedandprovidedinconformancewiththeapplicablecodeadoptedbythejurisdictionandmanufacturer'sinstallationrequirements
Ininstanceswhereconflictsoccurbetweenthecodeandthemanufacturer'sinstallationinstructions,themorerestrictiveprovisionsshallapply
Inabsenceofalocalcode,combustionairshallbecalculatedandprovidedinconformancewithanyofthefollowing:NFPA54,IFGC,orNFPA31
Objective(s):Ensureadequatecombustionairforoperationoftheappliance
Baseload>WaterHeating>InstallationandReplacement7.8102.4k-Ventingoffluegases
7.8102.4k-VentingoffluegasesDesiredOutcome:Safeandreliablehotwatersourceprovidedthatmeetsoccupantneedsatlowestpossiblecostofownership
Specification(s):Combustionbyproductsshallberemovedinaccordancewiththeapplicablecodeadoptedbythejurisdictionandmanufacturer'sinstallationrequirements
Ininstanceswhereconflictsoccurbetweenthecodeandthemanufacturer'sinstallationinstructions,themorerestrictiveprovisionsshallapply
Inabsenceofalocalcode,combustionbyproductsshallberemovedinaccordancewithanyofthefollowing:NFPA54,IFGC,orNFPA31
Objective(s):Ensurethesafetyanddurabilityoftheventingsystem
Baseload>WaterHeating>InstallationandReplacement7.8102.4l-Combustiontesting
7.8102.4l-CombustiontestingDesiredOutcome:Safeandreliablehotwatersourceprovidedthatmeetsoccupantneedsatlowestpossiblecostofownership
Specification(s):Undilutedfluegaseswillbecheckedwithacalibratedfluegasanalyzerinaccordancewithacceptedprotocol
Ifcombustionisnothappeningsafelyortotheappropriatecombustionefficiency,diagnosticsandadjustmentswillbedoneinaccordancewithmanufacturerspecificationsandlocalcodes
Objective(s):Confirmthatcombustionisoccurringsafelywithappropriatecombustionefficiency
Baseload>WaterHeating>InstallationandReplacement7.8102.4m-Fuelsupply
7.8102.4m-FuelsupplyDesiredOutcome:Safeandreliablehotwatersourceprovidedthatmeetsoccupantneedsatlowestpossiblecostofownership
Specification(s):Electric,naturalgas,andoilsupplycomponentswillbeinstalledtoacceptedindustrystandardsandcodesinaccordancewithNFPA70(NEC)forelectric,NFPA54forgas,orNFPA31foroil
Energyinputrequiredbytheappliancewillbeinaccordancewithmanufacturerspecifications(e.g.,ensuregaspipesizeandpressureareadequate)
Objective(s):Providesufficientfueltothewaterheater,burner,orelement
Baseload>WaterHeating>InstallationandReplacement7.8102.4n-Dischargewatertemperature
7.8102.4n-DischargewatertemperatureDesiredOutcome:Safeandreliablehotwatersourceprovidedthatmeetsoccupantneedsatlowestpossiblecostofownership
Specification(s):Dischargewatertemperatureatfixtureswillnotexceed120°Forasprescribedbylocalcode
Installmixingvalvewhenhigherstorage/generationtemperaturesarerequired
Objective(s):Ensuresafehotwatersupplytemperaturetofixtures
Baseload>WaterHeating>InstallationandReplacement7.8102.4o-Commissioningofsystem
7.8102.4o-CommissioningofsystemDesiredOutcome:Safeandreliablehotwatersourceprovidedthatmeetsoccupantneedsatlowestpossiblecostofownership
Specification(s):Thefollowingwillbecheckedoncethesystemhasbeenfilledandpurged:
SafetycontrolsCombustionsafetyandefficiencyOperationalcontrolsFuelandwaterleaksLocalcoderequirements
Commissioningwillbeinaccordancewithmanufacturerspecificationsandrelevantindustrystandards
Objective(s):Ensuresystemfunctionssafely
Keepcostofownershipaslowaspossible
Baseload>WaterHeating>InstallationandReplacement7.8102.4p-Occupanthealthandsafety
7.8102.4p-OccupanthealthandsafetyDesiredOutcome:Safeandreliablehotwatersourceprovidedthatmeetsoccupantneedsatlowestpossiblecostofownership
Specification(s):Allspaceswithcombustionapplianceswillhaveacarbonmonoxide(CO)alarm
LocationsofCOalarmsinthespaceshallbeinaccordancewithstatelawandlocalcodes
AmbientCOlevelswillbemaintainedundercode-acceptablethresholds
Objective(s):Ensureoccupanthealthandsafety
Baseload>WaterHeating>InstallationandReplacement7.8102.4q-Occupanteducation
7.8102.4q-OccupanteducationDesiredOutcome:Safeandreliablehotwatersourceprovidedthatmeetsoccupantneedsatlowestpossiblecostofownership
Specification(s):Completedworkwillbereviewed
Completedworkwillbereviewed
Occupant/buildingoperationsstaff/propertymanagerwillbeeducatedonthesafeandefficientoperationand
maintenanceofthesystem,including:
AdjustmentofwatertemperatureOperationofbackflowpreventerandpressureregulatorImportanceofkeepingoperatingmanualsaccessible
Objective(s):Educateoccupant/buildingoperationsstaff/propertymanageraboutthesafe,efficientoperationandmaintenanceofthesystem
Baseload>WaterHeating>Maintenance/Inspection
7.8103.7-CrossoverDuetoaBackflowintotheColdWaterSupplyDesiredOutcome:Minimizeenergyandwaterwastetothelowestpossiblelifecyclecost
Note:
Baseload>WaterHeating>Maintenance/Inspection7.8103.7a-Hazardousmaterialremoval
7.8103.7a-HazardousmaterialremovalDesiredOutcome:Minimizeenergyandwaterwastetothelowestpossiblelifecyclecost
Specification(s):Healthconcernsintheremovalandreplacementofequipment(e.g.,asbestos,otherhazardousmaterials)willbeidentified
Writtennotificationwillbeprovidedtooccupantsofthediscoveryofhazardousmaterial,includingcontactinformationforregionalEPAasbestoscoordinator
OccupantwillbeaskedtocontractwithanEPA-certifiedasbestoscontractortoconductabatementbeforedecommissioningandreplacement(occupantisresponsibleforabatementorremediation)
Objective(s):RemediatehealthhazardsusingEPA-certifiedcontractors
Baseload>WaterHeating>Maintenance/Inspection7.8103.7b-Installation
7.8103.7b-InstallationDesiredOutcome:Minimizeenergyandwaterwastetothelowestpossiblelifecyclecost
Specification(s):Checkvalvewillbeinstalledonthecoldwatersupplytothewaterheatingequipment
Athermalexpansiontankwillbeinstalled,ifnotpresent
Objective(s):Eliminatecrossover
Baseload>WaterHeating>Maintenance/Inspection7.8103.7c-Commissioning
7.8103.7c-CommissioningDesiredOutcome:Minimizeenergyandwaterwastetothelowestpossiblelifecyclecost
Specification(s):Waterpressuredownstreamofthecheckvalvewillbeverified
ExpansiontankchargewillbeverifiedorsetinaccordancewithSWS7.8104.8DomesticHotWaterExpansionTank(PotableWater)
Objective(s):Ensureproperoperation
Baseload>WaterHeating>Distribution
7.8104.8-DomesticHotWaterExpansionTank(PotableWater)DesiredOutcome:Provideforadequateexpansionofdomestichotwaterasitisheatedtopreventdamagetopipingandequipment
Note:
Baseload>WaterHeating>Distribution7.8104.8a-Adequateairpressureofexistingairtank
7.8104.8a-AdequateairpressureofexistingairtankDesiredOutcome:Provideforadequateexpansionofdomestichotwaterasitisheatedtopreventdamagetopipingandequipment
Specification(s):Unitwillbehydraulicallyisolatedandremovedfrompipinganddraintank
Capwillberemovedonbottomoftank
Pressurewillbecheckedusingatirepressuregauge
Pressurewillbecloselymatchedtoincomingwaterpressure
Objective(s):Ensurethatexpansiontankisproperlychargedandoperating
Baseload>WaterHeating>Distribution7.8104.8b-Propersizingofnewexpansiontank
7.8104.8b-PropersizingofnewexpansiontankDesiredOutcome:Provideforadequateexpansionofdomestichotwaterasitisheatedtopreventdamagetopipingandequipment
Specification(s):Collectnecessaryinformationtodetermineexpansiontanksize,including:
Operatingwaterpressureofwaterheater(apressuregaugemayneedtobeinstalledtoverify)WaterheaterandtankvolumeOperatingwatertemperatureRelievevalvepressuresettingValueofincomingstreetwaterpressure
Objective(s):Ensurethatthenewlyinstalledexpansiontankwillbeproperlysizedforthesystem
Baseload>WaterHeating>Distribution7.8104.8c-Prechargeairpressureinnewexpansiontank
7.8104.8c-PrechargeairpressureinnewexpansiontankDesiredOutcome:Provideforadequateexpansionofdomestichotwaterasitisheatedtopreventdamagetopipingandequipment
Specification(s):Usingatirepressuregaugeandatirepumptoadjustasnecessary,pressureinpotablewaterexpansiontankwillbesettomatchtheincomingstreetwaterpressure
Objective(s):Setcorrectairpressureforproperoperationoftank
Baseload>WaterHeating>Distribution7.8104.8d-Newinstallationlocationofexpansiontank
7.8104.8d-NewinstallationlocationofexpansiontankDesiredOutcome:Provideforadequateexpansionofdomestichotwaterasitisheatedtopreventdamagetopipingandequipment
Specification(s):Expansiontankshallbeinstalledinaccordancewiththemanufacturer'sinstallationinstructions
Theexpansiontankwillbelocatedonthecoldwaterinlettothewaterheater
Theexpansiontankshouldbelocatedbetweenthewaterheatingequipmentandtherequiredshutoff
Objective(s):Ensurecorrectlocationoftank
Baseload>Baseload—SpecialConsiderations>Elevators
7.8801.1-ReplacementandMaintenanceDesiredOutcome:Properoperationofelevator
Note:Theauthorityhavingjurisdictionmayrequirethatalicensedprofessionalperformcertaintasksoutlinedinthisdetail.
Baseload>Baseload—SpecialConsiderations>Elevators7.8801.1a-Inspection
7.8801.1a-InspectionDesiredOutcome:Properoperationofelevator
Specification(s):Inspectionwillbeperformedbyalicensedelevatorprofessional
Objective(s):Ensureoccupantsafety
Baseload>Baseload—SpecialConsiderations>Elevators7.8801.1b-Energyefficiency
7.8801.1b-EnergyefficiencyDesiredOutcome:Properoperationofelevator
Specification(s):Evaluationwillbeperformedbyalicensedelevatorprofessionalinconjunctionwithenergyefficiencyprofessionals
Elevatorroomheating,ventilation,andairconditioningequipmentwillbeinstalledwithenergyefficientcomponentsandpropercontrols
Objective(s):Optimizeenergyperformance
Baseload>Baseload—SpecialConsiderations>Elevators7.8801.1c-Installationandmaintenance
7.8801.1c-InstallationandmaintenanceDesiredOutcome:Properoperationofelevator
Specification(s):AnyworkwillbeperformedtocomplywithASMEA17.1,ICCA117.1,andANSINFPA70Article620
Objective(s):Ensureoccupantsafety
Ensureproperinstallation