residential infiltration and testing -...
TRANSCRIPT
-
California Statewide Utility Codes and Standards Program
04/12/2011
1
Residential Infiltration and
Testing
Residential Stakeholder Meeting #2
Bruce Wilcox
April 12, 2011
-
CALIFORNIA STATEWIDE UTILITIES CODES AND STANDARDS PROGRAM
04/12/2011
2 2
Residential Infiltration and Testing
● Summary of current code requirements
● Typical practice
● Summary of code change proposals
● Data/findings
● Specifics of code change proposals
● Specific stakeholder requests
CA Utilities 2011 Title 24 Stakeholder Meeting for Proposed Code Changes
-
CALIFORNIA STATEWIDE UTILITIES CODES AND STANDARDS PROGRAM
04/12/2011
3
Infiltration and Testing
Current Code Requirements
● Prescriptive air sealing
● Caulk and seal
● Certification requirements for windows, ceiling
cans etc
● Performance credit for air barrier
● Performance credit for leakage testing
● Credit for tested air leakage (HERS verified)
● Credit potentially much larger in 2008 Standards
● Effectively no multi-family testing option
● Blower door testing of whole building is
impractical
CA Utilities 2011 Title 24 Stakeholder Meeting for Proposed Code Changes
-
CALIFORNIA STATEWIDE UTILITIES CODES AND STANDARDS PROGRAM
04/12/2011
4
Infiltration and Testing
Typical Practice
● Single family
● Usually default
● No air sealing measures
● No credits
● Some production builders take credit
● Problem of no air sealing contractor
● HERS raters provide testing
● Much bigger credit in 2008 - mechanical ventilation
removes lower limit on air leakage
● Multi-Family no action
CA Utilities 2011 Title 24 Stakeholder Meeting for Proposed Code Changes
-
CALIFORNIA STATEWIDE UTILITIES CODES AND STANDARDS PROGRAM
04/12/2011
5
Infiltration and Testing
Code Change Proposal Summary
● Base code prescriptive maximum air leakage
rate of 4 ACH50 for single family homes in
12 climates
● 3 ACH50 requirement for single family
Reach Standards in 13 climates
● No multi-family requirements
● Use new Resnet Draft Standard 802
● Eliminate current air barrier credit
CA Utilities 2011 Title 24 Stakeholder Meeting for Proposed Code Changes
-
CALIFORNIA STATEWIDE UTILITIES CODES AND STANDARDS PROGRAM
Infiltration and Testing
California New Home Energy Survey
● 40 Single family and 40 Multi-family
● Sample drawn from electric customers of SCE, PG&E and
SDG&E
● New homes 1st connected in 2007, probably 2005 Stds
● Occupied for 2 years
● Geographic distribution of surveys matched to sample at 3
digit zip level
● Mailed invitation letter with prepaid reply letter, web site and
800 number for responses. Recruited by phone from
responders.
● Occupants received $100 for participation
04/12/2011
6
CA Utilities 2011 Title 24 Stakeholder Meeting for Proposed Code Changes
-
CALIFORNIA STATEWIDE UTILITIES CODES AND STANDARDS PROGRAM
Infiltration and Testing
Survey Air Leakage Measurements
● Simple Single Point Blower Door (CFM & ACH50)
● Single point, no baseline
● Air flow at 50 Pa (CFM50 or ACH50) Pressure and
depressure
● ASTM E1827-02 Air Leakage at 50 Pa
● Repeated measurements with baseline
● Air flow at 50 Pa (CFM50 or ACH50) Pressure and
depressure
● Series measurements for leakage to attic and garage]
● E779-03 Air Leakage
● Effective Leakage Area (ELA/SLA) pressure and depressure
● Fireplace Leakage
04/12/2011
7
CA Utilities 2011 Title 24 Stakeholder Meeting for Proposed Code Changes
-
CALIFORNIA STATEWIDE UTILITIES CODES AND STANDARDS PROGRAM
04/12/2011
8
Infiltration and Testing
Envelope Air Leakage SLA (Specific Leakage Area)
0
1
2
3
4
5
6
7
1 19 37
Spec
ific
Lea
kage
Are
a (S
LA)
SF
Apartment
TownHouse
ACM Sealed
ACM Leaky
CA Utilities 2011 Title 24 Stakeholder Meeting for Proposed Code Changes
-
CALIFORNIA STATEWIDE UTILITIES CODES AND STANDARDS PROGRAM
04/12/2011
9
Infiltration and Testing
Envelope Air Leakage ACH50 (Air Changes @ 50 Pa.)
0
2
4
6
8
10
12
1 19 37
Air
Ch
ange
s at
50
Pa
SF
Apartment
TownHouse
CA Utilities 2011 Title 24 Stakeholder Meeting for Proposed Code Changes
-
CALIFORNIA STATEWIDE UTILITIES CODES AND STANDARDS PROGRAM
Infiltration and Testing
Envelope Air Leakage Survey Summary
● Single Family homes are very tight
● Multi–Family homes are much leakier
● Homes with attics and attached garages:
● 47% of the total leakage area is from/to the attic
● 9% of the total leakage area is from/to the
garage
04/12/2011
10
CA Utilities 2011 Title 24 Stakeholder Meeting for Proposed Code Changes
-
CALIFORNIA STATEWIDE UTILITIES CODES AND STANDARDS PROGRAM
04/12/2011
11
Infiltration and Testing
Using New CSE Infiltration Algorithm
leaks &
windows
Sup
Ret
SupLeak
RetLeaK
HVAC
House
Attic
s
Sup
Ret
Tout
Tout
Fan Big Leak
CA Utilities 2011 Title 24 Stakeholder Meeting for Proposed Code Changes
-
CALIFORNIA STATEWIDE UTILITIES CODES AND STANDARDS PROGRAM
04/12/2011
12
Infiltration and Testing
TDV Energy vs Air Tightness
leaks &
windows 0
20
40
60
80
100
120
140
160
180
1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16
Tim
e D
ep
en
de
nt
Val
ue
, kTD
V/f
t2
Climate Zone
ACH 7.6
ACH 5
ACH 4
ACH 3
CA Utilities 2011 Title 24 Stakeholder Meeting for Proposed Code Changes
-
CALIFORNIA STATEWIDE UTILITIES CODES AND STANDARDS PROGRAM
04/12/2011
13
Infiltration and Testing
Air Sealing 2200 ft2 Production Home
5 ACH50 4 ACH50 3 ACH50
Labor 50 75 100
Materials 59 89 118
Sub Overhead and profit 109 164 218
Subcontractor Invoice to builder 218 327 436
HERS verification 130 130 130
Total cost to builder 348 457 566
Builder Markup 30% 104 137 170
Total cost to Home buyer 452 594 736
$/cfa 0.21$ 0.27$ 0.33$
CA Utilities 2011 Title 24 Stakeholder Meeting for Proposed Code Changes
-
CALIFORNIA STATEWIDE UTILITIES CODES AND STANDARDS PROGRAM
Infiltration and Testing
Life Cycle Cost Savings for Air Sealing
● 2700 ft2 CEC Prototype, Base TDV
04/12/2011
14
-2000
-1000
0
1000
2000
3000
4000
1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16
$
Climate Zone
ACH 5
ACH 4
ACH 3
CA Utilities 2011 Title 24 Stakeholder Meeting for Proposed Code Changes
-
CALIFORNIA STATEWIDE UTILITIES CODES AND STANDARDS PROGRAM
Infiltration and Testing
Reach Life Cycle Cost Savings
● 2700 ft2 CEC Prototype, Reach TDV
04/12/2011
15
-2000
-1000
0
1000
2000
3000
4000
5000
6000
1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16
$
Climate Zone
ACH 5
ACH 4
ACH 3
CA Utilities 2011 Title 24 Stakeholder Meeting for Proposed Code Changes
-
CALIFORNIA STATEWIDE UTILITIES CODES AND STANDARDS PROGRAM
Infiltration and Testing
Code Change Proposals
● Base prescriptive maximum air leakage
● 4 ACH50 criteria with 7.6 default
● All new single family homes in 12 climates
● Post construction blower door test
● HERS verification
● Tighter requirement for reach standards
● 3 ACH50 criteria
● New single family homes in 13 climates
04/12/2011
16
CA Utilities 2011 Title 24 Stakeholder Meeting for Proposed Code Changes
-
CALIFORNIA STATEWIDE UTILITIES CODES AND STANDARDS PROGRAM
Infiltration and Testing
No Action in Multi-family
● Unit by unit tests show big leakage, but
● Some unknown fraction of the leakage is to
other units. Sealing improves IAQ, but energy
savings unknown.
● Testing whole building is not practical, but
whole building compliance is standard.
● More research is needed (PIER?)
● Energy savings from unit by unit air sealing
● Test standard for multi-family ACH50
04/12/2011
17
CA Utilities 2011 Title 24 Stakeholder Meeting for Proposed Code Changes
-
CALIFORNIA STATEWIDE UTILITIES CODES AND STANDARDS PROGRAM
Infiltration and Testing
New Base Code Language in Section 151
04/12/2011
18
2008 Building Energy Efficiency Standards – June 2007 Workshop Draft
(f) Prescriptive Standards/Alternative Component Packages (Component Packages).
….
13. Maximum Envelope Air Leakage.
A. The exterior pressure envelope of the home shall be sealed to achieve a tested air leakage less than or
equal to the criteria in TABLE 151-C COMPONENT PACKAGE D using the criteria in Reference Appendix
YYY.
EXCEPTION to Section 151 (f) 13 A: Multi-family buildings are exempt.
TABLE 151-C COMPONENT PACKAGE D
Climate Zone 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16
BUILDING ENVELOPE
Maximum Envelope Air
Leakage
CFM50 4 4 NR 4 4 NR NR NR 4 4 4 4 4 4 4 4
CA Utilities 2011 Title 24 Stakeholder Meeting for Proposed Code Changes
-
CALIFORNIA STATEWIDE UTILITIES CODES AND STANDARDS PROGRAM
04/12/2011
19
Infiltration and Testing
New Reach Code Language
(?) Reach Standards/Alternative Component Packages (Component Packages).
….
13. Maximum Envelope Air Leakage.
A. The exterior pressure envelope of the home shall be sealed to achieve a tested air leakage less than or equal to
the criteria in TABLE ???-C COMPONENT PACKAGE ?? using the criteria in Reference Appendix YYY.
EXCEPTION to Section ??? (?) 13 A: Multi-family buildings are exempt.
TABLE ???-C COMPONENT PACKAGE ??
Climate Zone 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16
BUILDING ENVELOPE
Maximum
Envelope Air
Leakage
CFM50 3 3 3 3 3 NR NR NR 3 3 3 3 3 3 3 3
CA Utilities 2011 Title 24 Stakeholder Meeting for Proposed Code Changes
-
CALIFORNIA STATEWIDE UTILITIES CODES AND STANDARDS PROGRAM
04/12/2011
20
Infiltration and Testing
Proposed Standards vs Survey Data
0
1
2
3
4
5
6
7
8
9
1 19 37
Air
Ch
ange
s at
50
Pa
SF Data
Base
Reach
Default
CA Utilities 2011 Title 24 Stakeholder Meeting for Proposed Code Changes
-
CALIFORNIA STATEWIDE UTILITIES CODES AND STANDARDS PROGRAM
Infiltration and Testing
RACM Changes
● Air leakage calculations
● Convert SLA to ACH50 everywhere
● Untested default 7.6 ACH50 (SLA 3.8)
● Eliminate current air barrier credit
● 47% of leakage between house and attic
● New CSE integrated air flow network
● Air leakage testing and verification
● Reference/copy Resnet Draft Standard 802:
● PROCEDURES FOR BUILDING ENCLOSURE AIRTIGHTNESS
TESTING
● http://www.resnet.us/blog/resnet-proposes-amendments-
to-national-home-energy-rating-standards-6/
04/12/2011
21
CA Utilities 2011 Title 24 Stakeholder Meeting for Proposed Code Changes
http://www.resnet.us/blog/resnet-proposes-amendments-to-national-home-energy-rating-standards-6/http://www.resnet.us/blog/resnet-proposes-amendments-to-national-home-energy-rating-standards-6/http://www.resnet.us/blog/resnet-proposes-amendments-to-national-home-energy-rating-standards-6/http://www.resnet.us/blog/resnet-proposes-amendments-to-national-home-energy-rating-standards-6/http://www.resnet.us/blog/resnet-proposes-amendments-to-national-home-energy-rating-standards-6/http://www.resnet.us/blog/resnet-proposes-amendments-to-national-home-energy-rating-standards-6/http://www.resnet.us/blog/resnet-proposes-amendments-to-national-home-energy-rating-standards-6/http://www.resnet.us/blog/resnet-proposes-amendments-to-national-home-energy-rating-standards-6/http://www.resnet.us/blog/resnet-proposes-amendments-to-national-home-energy-rating-standards-6/http://www.resnet.us/blog/resnet-proposes-amendments-to-national-home-energy-rating-standards-6/http://www.resnet.us/blog/resnet-proposes-amendments-to-national-home-energy-rating-standards-6/http://www.resnet.us/blog/resnet-proposes-amendments-to-national-home-energy-rating-standards-6/http://www.resnet.us/blog/resnet-proposes-amendments-to-national-home-energy-rating-standards-6/http://www.resnet.us/blog/resnet-proposes-amendments-to-national-home-energy-rating-standards-6/http://www.resnet.us/blog/resnet-proposes-amendments-to-national-home-energy-rating-standards-6/http://www.resnet.us/blog/resnet-proposes-amendments-to-national-home-energy-rating-standards-6/http://www.resnet.us/blog/resnet-proposes-amendments-to-national-home-energy-rating-standards-6/http://www.resnet.us/blog/resnet-proposes-amendments-to-national-home-energy-rating-standards-6/http://www.resnet.us/blog/resnet-proposes-amendments-to-national-home-energy-rating-standards-6/http://www.resnet.us/blog/resnet-proposes-amendments-to-national-home-energy-rating-standards-6/
-
CALIFORNIA STATEWIDE UTILITIES CODES AND STANDARDS PROGRAM
04/12/2011
22
Infiltration and Testing
Specific Stakeholder Requests
● Review and comment on
● Proposed Standard
● Cost of air sealing in CA homes
● Cost of CA testing and verification
● Proposed test and verification procedure
CA Utilities 2011 Title 24 Stakeholder Meeting for Proposed Code Changes
-
CALIFORNIA STATEWIDE UTILITIES CODES AND STANDARDS PROGRAM
04/12/2011
23
Residential Infiltration and Testing
QUESTIONS & COMMENTS