Compliance with Standards
ICAO: Aerodrome Design Manual Part 5, para. 3.2 (CurrentEdition)
IEC: 61822
CENELEC: EN61822
Various National Standards
CE Certified
UsesThe RELIANCE® Pure Sine Wave CCR is specifically designed to supplyairport lighting series circuits at various intensity levels. The highprocessing speed of the CCR contributes substantially to coping withpresent day circuits and their ever-changing demands.
Benefits & Features
• Small size and low weight Constant Current Regulator.• The CCR is a single output unit of modular design.• Up to six 5kVA Power Modules in one housing.• The modular design reduces MTTR to less than 10 min.• Uses up to 66% less space in the substation.• Significantly reduces the CCR substation footprint.• True sinusoidal wave, low harmonic output.• High regulation precision and response dynamic, thanks to high
frequency PWM - Transistor technology.• Stable output current under all circumstances and load profiles.• Automaticly adapts to the load, no load matching required.• Different housing topologies.• Remote network control and monitoring functionality.• Separate diagnostic network functionality.• Optional built-in lamp & earth fault detection.• Optional built-in Input Overvoltage Protection.• Plug and play servicing.• Fast and Easy installation.• Dedicated web interface for easy maintenance.• Perfectly suited for new technology LED lights as well as
conventional lamp lights.
Concept
Innovative Technology
By using state of the art high frequency modultated transistortechnology, the power regulation is reduced significantly in size. Thecurrent is regulated in 5 kVA power modules. Multiple power modulescan be combined in different housings to achieve power ratings up to30 kVA.
Small Substation Footprint
The CCR is designed to be small in size and lightweight. The designallows the CCR to be stacked on industrial shelves, significantlyreducing the substation footprint.
Flexible Layout
The required CCR power rating is attained by combining 5kVA powermodules. Frames exist that house two, four or six power modules.Using this modular set-up, the CCR can be configured for future seriescircuit extensions.
Maximum Efficiency
The innovative CCR configuration and smart power distribution allowsfor very high efficiency under all load profiles.
Easy Serviceability
Precise error notification and cold swappable power modulessignificantly reduces the maintenance and troubleshooting periods,thus lowering the MTTR under 10 min.
Simplified Maintenance
The 5 kVA power modules are individual serviceable andergonomically designed.
Finish
• Alloy 1060 hardware• Baked epoxy powder coating, fine structure• Color: RAL 7035 warm gray & black
RELIANCEPower HF
DS-4005-v2.1_2020_October_28 1
Power HF
ConstructionThe RELIANCE Power HF type CCRs are stand-alone units, eachhousing a complete regulator in one enclosure, divided into twocompartments:1. A low-voltage top compartment, containing the power, the
control and monitoring PCBs, and a fused input switch.2. A high-voltage bottom compartment, containing the power
modules and lightning arrestors.
Depending on the rating of the CCR, the units are supplied in threedifferent sized frames.
Options
Lamp- (LFD) and Earth Fault Detection (EFD)
The LFD provides accurate and real-time detection of the number ofburnt-out lamps in a series circuit. The EFD measures the insulationresistance of the series circuit to the ground, with the regulator bothON and OFF. Measurement range up to 1GΩ. The number of failedlamps and the isolation resistance of the circuit are reported to thealphanumerical display on the CCR front. The two alarm levels foreach function can be adjusted via customer settable parameters.
Over-voltage protection
Protects the input against over-voltage spikes by means of optional40kA 8/20 μS surge arrestors.
Rolling castors
The CCR can be equipped with feet for installation on industrial racksor two fix and two pivoting rolling castors to ease displacementduring service activities.
Technical Data
Rated Power(kVA)
5 – 10 – 15 – 20 – 25 – 30
Rated InputVoltage
400 VAC ± 10 %
RatedFrequencies
50 ± 7.5 %
Output Current 6.60 A ± 0.1 A
Remote Control Multiwire 24 VDCMultiwire 48 VDCSingle Modbus serial RS485/RS422Dual Modbus serial RS485/RS422Single ModBus TCP/IPDual Modbus TCP/IP
Temperature Operating temperature: -40°C to +55°CTemperature rise under the most adverseconditions meets ANSI C57.12.91Degree of protection: IP 20
BrightnessControl
Up to 8 brightness steps, user adjustable in 65klevels (1mA resolu-tion) Output currentregulation. Within ± 1% for all the brightnesssteps, under IEC conditions.
RegulationResponse Time
Less than 500ms seconds at full (100%) resistiveload (power factor = 1)
Open circuitoutput voltage
Less than 1.4 times the nominal output voltage(RMS)
Efficiency
90 to 92% (or better) depending on the CCR size, under nominalresistive load, nominal output current and nominal input voltage
Primary power factor
› 0,9 for ratings up to 10 kVA
› 0,95 for ratings 15 kVA and up under nominal resistive load, nominaloutput current and nominal input voltage
Dimensions and Weight
CCR Size Enclosure W x D x H (mm) Weight (kg)
5 kVA 630 x 770 x 510 61
10 kVA 630 x 770 x 510 82
15 kVA 630 x 770 x 820 100
20 kVA 630 x 770 x 820 118
25 kVA 630 x 770 x 1136 136
30 kVA 630 x 770 x 1136 154
RELIANCE
DS-4005-v2.1_2020_October_28 2
Ordering Code 1HFOutput Power/CurrentC2 = 5 kVA/6.6AE2 = 10 kVA/6.6AG4 = 15 kVA/6.6AH4 = 20 kVA/6.6AJ6 = 25 kVA/6.6AK6 = 30 kVA/6.6AInput Voltage (50/60Hz)2 = 380/400Remote Control0 = No interfacesA = Multiwire 24VDC + Single TCP/IP + Single RS485
/RS422B = Multiwire 48VDC + Single TCP/IP + Single
RS485/RS422C = Single Modbus TCP/IPD = Dual Modbus TCP/IPE = Single Modbus RS485/RS422F = Dual Modbus RS485/RS422EFD and LFD0 = No EFD/LFDE = EFD/LFD includedInput Over Voltage Protection0 = None1 = IncludedFixed Digit0 = Fixed DigitSupport0 = Feet1 = WheelsFixed Digit0 = Fixed DigitFixed Digit0 = Fixed DigitFixed Digit0 = Fixed DigitFixed Digit0 = Fixed DigitVersion1 = Version
RELIANCE
www.adbsafegate.com
Product specifications may be subject to change, and specifications listed here are notbinding. Confirm current specifications at time of order.
DS-4005-v2.1_2020_October_28 3