Page 1: Rectifier and Bond Reading Tim Jenkins. Basic Electric - Shunts

Rectifier and Bond Reading

Tim Jenkins

Page 2: Rectifier and Bond Reading Tim Jenkins. Basic Electric - Shunts

Basic Electric - Shunts

Page 3: Rectifier and Bond Reading Tim Jenkins. Basic Electric - Shunts

Basic Electric - Shunt Formulas

• Calculate Current– Given - Shunt ( .01 ohms & voltage across the shunt = 50 Mv)

– Convert units of voltage, 50mv = .05v

– Calculate current using Ohm’s law• I = .05 v/.01 ohms = 5 amps

– Given - Shunt ( 15 amps, 50mV)• Measured voltage drop = 28mV

– Determine shunt rating• Rating = 15 amps/50mV = .3 amps / mV

– Calculate current• Current = .3 amps / mV x 28 mV = 8.4 amps

Page 4: Rectifier and Bond Reading Tim Jenkins. Basic Electric - Shunts
Page 5: Rectifier and Bond Reading Tim Jenkins. Basic Electric - Shunts
Page 6: Rectifier and Bond Reading Tim Jenkins. Basic Electric - Shunts

Slide Resister Application

Page 7: Rectifier and Bond Reading Tim Jenkins. Basic Electric - Shunts

Resister Wire Application

The amount of Resistance is made by the Length of the Wire.

Page 8: Rectifier and Bond Reading Tim Jenkins. Basic Electric - Shunts

Disconnect Bond Wire for Amp Drain Reading

Page 9: Rectifier and Bond Reading Tim Jenkins. Basic Electric - Shunts

Amp Drain Reading

Make Connection in series with the Circuit

1.36 Amp Current Drain

Page 10: Rectifier and Bond Reading Tim Jenkins. Basic Electric - Shunts
Page 11: Rectifier and Bond Reading Tim Jenkins. Basic Electric - Shunts

Slide Resister

Lighting Arrestor

Page 12: Rectifier and Bond Reading Tim Jenkins. Basic Electric - Shunts

Connection Made on Resister from Foreign Structure and Columbia.

Page 13: Rectifier and Bond Reading Tim Jenkins. Basic Electric - Shunts

Disconnection to get Amp Drain must be made in series with the circuit.

Page 14: Rectifier and Bond Reading Tim Jenkins. Basic Electric - Shunts

Direct Bond Connection, No Resistance

Page 15: Rectifier and Bond Reading Tim Jenkins. Basic Electric - Shunts

Shunt Resister

Page 16: Rectifier and Bond Reading Tim Jenkins. Basic Electric - Shunts

Measuring Amp Drain by Measuring Voltage Drop Across the Shunt. Ratio is normally found on Shunt. .001V = 1A

Page 17: Rectifier and Bond Reading Tim Jenkins. Basic Electric - Shunts

7 milivolts = 7 Amps

Polarity does not matter.

Make connection across Shunt.

Page 18: Rectifier and Bond Reading Tim Jenkins. Basic Electric - Shunts

Ratio for Shunt

Shunts do not have to be disconnected in BI-monthly and Annual inspection.

Page 19: Rectifier and Bond Reading Tim Jenkins. Basic Electric - Shunts

Connect meter in serious for amp reading

on the structure or anode wire.

Alternative method – use shunt for amp readings.

Take mili-volt reading across shunt then use ratio to figure total amps.