pvc data cables - igus.eu...122 eu04.2019 eu04.2019 123 cf240 pvc 10 x d data cable | pvc |...

20
117 Guarantee month guarantee 36 month chainflex ® guarantee Guaranteed lifetime for predictable reliability Selection table page 118 With the help of the chainflex ® service life calculator, you can quickly and easily calculate the expected service life of chainflex ® cables specifically for your application: www.igus.eu/chainflexlife Data cables Coax cables chainflex ® cable Jacket Shield Minimum bend radius. e-chain ® [factor x d] Temperature. e-chain ® from/to [°C] Approvals and standards Oil-resistant Torsion resistant v max. [m/s]. unsupported v max. [m/s] gliding a max. [m/s 2 ] Page Data cables – Wound in layers CF8821 PVC 12.5 +5/+70 3 20 120 CF240 PVC 10 +5/+70 3 2 20 122 CF240.PUR PUR 10 -25/+80 3 2 20 126 Data cables – Twisted pair CF211 PVC 7.5 +5/+70 5 3 50 130 CF211.PUR PUR 7.5 -25/+80 5 3 50 134 CF11 TPE 6.8 -35/+100 10 6 100 138 Data cables – Twisted pair with pair shield CF112 PUR 10 -25/+80 10 5 80 142 CF12 TPE 10 -35/+100 10 6 100 146 Data cables – Wound in layers CF298 TPE 4 -35/+90 10 6 100 148 CF299 TPE 4 -35/+90 10 6 100 150 Coax cables CFKoax TPE 10 -35/+100 -35/+70 10 5 100 152 New

Upload: others

Post on 16-Oct-2020

3 views

Category:

Documents


0 download

TRANSCRIPT

Page 1: PVC Data cables - igus.eu...122 EU04.2019 EU04.2019 123 CF240 PVC 10 x d Data cable | PVC | chainflex® CF240 Dynamic information Bend radius e-chain® linear minimum 10 x d flexible

117116 EU04

.201

9

Guarantee

month guarantee

36 month chainflex® guaranteeGuaranteed lifetime for predictable reliabilitySelection table page 118

With the help of the chainflex® service life calculator, you can quickly and easily calculatethe expected service life of chainflex® cables specifically for your application:

www.igus.eu/chainflexlifeDat

a ca

bles

Coa

x ca

bles

chai

nflex

®

cabl

e

Jack

et

Shi

eld

Min

imum

ben

d

radi

us. e

-cha

in®

[fact

or x

d]

Tem

pera

ture

. e-

chai

from

/to

[°C

]

App

rova

ls a

nd

stan

dard

s

Oil-

resi

stan

t

Tors

ion

resi

stan

t

v m

ax. [

m/s

]. un

supp

orte

d

v m

ax. [

m/s

] gl

idin

g

a m

ax. [

m/s

2 ]

Pag

e

Data cables – Wound in layers

CF8821 PVC 12.5 +5/+70 3 20 120

CF240 PVC 10 +5/+70 3 2 20 122

CF240.PUR PUR 10 -25/+80 3 2 20 126

Data cables – Twisted pair

CF211 PVC 7.5 +5/+70 5 3 50 130

CF211.PUR PUR 7.5 -25/+80 5 3 50 134

CF11 TPE 6.8 -35/+100 10 6 100 138

Data cables – Twisted pair with pair shield

CF112 PUR 10 -25/+80 10 5 80 142

CF12 TPE 10 -35/+100 10 6 100 146

Data cables – Wound in layers

CF298 TPE 4 -35/+90 10 6 100 148

CF299 TPE 4 -35/+90 10 6 100 150

Coax cables

CFKoax TPE 10-35/+100-35/+70 10 5 100 152

New

Page 2: PVC Data cables - igus.eu...122 EU04.2019 EU04.2019 123 CF240 PVC 10 x d Data cable | PVC | chainflex® CF240 Dynamic information Bend radius e-chain® linear minimum 10 x d flexible

119118

chainflex® cable

Temperature, from/to [°C]

v max. [m/s] a max. [m/s2]

Travel distance [m]

Minimum bend radius [factor x d]

Minimum bend radius [factor x d]

Minimum bend radius [factor x d]

Page

unsupported gliding < 10 m ≥ 10 m < 10 m ≥ 10 m < 10 m ≥ 10 m

Data cables 5 million (1 million) double strokes *

7.5 million (3 million) double strokes *

10 million (5 million) double strokes *

CF8821+5 / +15

3 - 20 ≤ 10

15 - 16 - 17 -

120+15 / +60 12.5 - 13.5 - 14.5 -

+60 / +70 15 - 16 - 17 -

5 million (10 million) 7.5 million (15 million) 10 million (20 million)

CF240+5 / +15

3 2 20 ≤ 50

12.5 15 13.5 16 14.5 17

122+15 / +60 10 12.5 11 13.5 12 14.5

+60 / +70 12.5 15 13.5 16 14.5 17

CF240.PUR-25 / -15

3 2 20 ≤ 50

12.5 15 13.5 16 14.5 17

126-15 / +70 10 12.5 11 13.5 12 14.5

+70 / +80 12.5 15 13.5 16 14.5 17

CF211+5 / +15

5 3 50 ≤ 100

10 11 12

130+15 / +60 7.5 8.5 9.5

+60 / +70 10 11 12

CF211.PUR-25 / -15

5 3 50 ≤ 100

10 11 12

134-15 / +70 7.5 8.5 9.5

+70 / +80 10 11 12

CF11-35 / -25

10 6 100 ≤ 400

7.5 8.5 9.5

138-25 / +90 6.8 7.5 8.5

+90 / +100 7.5 8.5 9.5

CF112-20 / -15

10 5 80 ≤ 100

12.5 13.5 14.5

142-15 / +70 10 11 12

+70 / +80 12.5 13.5 14.5

CF12-35 / -25

10 6 100 ≤ 400

12.5 13.5 14.5

146-25 / +90 10 11 12

+90 / +100 12.5 13.5 14.5

CF298-35 / -25

10 6 100 ≤ 100

5 6 7

148-25 / +80 4 5 6

+80 / +90 5 6 7

CF299-35 / -25

10 6 100 ≤ 100

5 6 7

150-25 / +80 4 5 6

+80 / +90 5 6 7

Coax Cables

CFKoax1/3-35 / -25

10 5 100 ≤ 400

12.5 13.5 14.5

152-25 / +90 10 11 12

+90 / +100 12.5 13.5 14.5

CFKoax2-35 / -25

10 5 100 ≤ 400

12.5 13.5 14.5

152-25 / +60 10 11 12

+60 / +70 12.5 13.5 14.5

(1) Exclusive! Guaranteed lifetime for this series according to the guarantee conditions Page 22-23 * Higher number of double strokes? Online lifetime calculation www.igus.eu/chainflexlifeFigures in brackets refer to chainflex® series CF8821 and CF298/CF299

chainflex® guarantee Guaranteed lifetime (1)

Page 3: PVC Data cables - igus.eu...122 EU04.2019 EU04.2019 123 CF240 PVC 10 x d Data cable | PVC | chainflex® CF240 Dynamic information Bend radius e-chain® linear minimum 10 x d flexible

121EU04

.201

9

EU04

.201

9

CF8821PVC

12.5 x d

z For flexing applications zPVC outer jacket z Shielded z Flame retardant

Data cable | PVC | chainflex® CF8821 E

xam

ple

imag

e

PVC iguPUR PUR TPE

EPLAN download, configurators www.igus.eu/CF8821

CF8821PVC

12.5 x dClass 3.1.1.1

Basic requirements low 1 2 3 4 5 6 7 highest

Travel distance unsupported 1 2 3 4 5 6 ≥ 400 m

Oil resistance none 1 2 3 4 highest

Torsion none 1 2 3 4 ±360°

Guaranteed service life (details see page 22-23)

Typical application areas

* Higher number of double strokes? Service life calculation online www.igus.eu/chainflexlife

1 million 3 million 5 million

Temperature,from/to [°C]

R min. [factor x d]

R min. [factor x d]

R min. [factor x d]

+5/+15 15 16 17

+15/+60 12.5 13.5 14.5

+60/+70 15 16 17

36 month guarantee ... 1,354 types from stock ... no cutting charges

z For flexing applications, Class 3 z Especially for unsupported travels, Class 1 z Without influence of oil, Class 1 z No torsion, Class 1 z Preferably indoor applications z Wood/stone processing, Packaging industry, supply systems, Handling, adjusting equipment

Double strokes*

Guarantee

month guarantee

5 millionDouble strokes guaranteed

12.5 x dBend radius, e-chain®

10 mTravel distance, e-chain®

Dynamic informationBend radius e-chain® linear minimum 12.5 x d

flexible minimum 10 x dfixed minimum 7 x d

Temperature e-chain® linear +5 °C up to +70 °Cflexible -5 °C up to +70 °C (following DIN EN 60811-504)fixed -15 °C up to +70 °C (following DIN EN 50305)

v max. unsupported 3 m/s

a max. 20 m/s²

Travel distance Unsupported travel distances up to 10 m, Class 1

Cable structureConductor Conductor consisting of bare copper wires (according to DIN EN 60228).

Core insulation Mechanically high-quality TPE mixture.

Core structure Cores wound with an optimised pitch length.

Core identification Colour code in accordance with DIN 47100.

Overall shield Braiding made of tinned copper wires.Coverage approx. 60 % optical

Outer jacket Low-adhesion PVC mixture, adapted to suit the requirements in e-chains®.Colour: Jet black (similar to RAL 9005)

Electrical informationNominal voltage 300/300 V (following DIN VDE 0298-3)

Testing voltage 1500 V (following DIN EN 50395)

Properties and approvalsFlame retardant According to IEC 60332-1-2, CEI 20-35, FT1, VW-1

Silicone-free Free from silicone which can affect paint adhesion (following PV 3.10.7 – status 1992)

UL/CSA Style 10493 and 2464, 300 V, 80 °C

NFPA Following NFPA 79-2018, chapter 12.9

Lead-free Following 2011/65/EC (RoHS-II)

CE Following 2014/35/EU

Part No.

Number of cores and conductor nominal cross section

Outer diameter (d) max.

Copper index

Weight

[mm²] [mm] [kg/km] [kg/km]CF8821.01.02 (2x0.14)C 5.0 11 31CF8821.01.03 (3x0.14)C 5.5 13 35CF8821.01.04 (4x0.14)C 5.5 15 41CF8821.01.05 (5x0.14)C 6.0 18 46CF8821.01.07 (7x0.14)C 6.5 23 57CF8821.02.02 (2x0.25)C 5.5 13 34CF8821.02.03 (3x0.25)C 5.5 16 40CF8821.02.04 (4x0.25)C 6.0 20 46CF8821.02.05 (5x0.25)C 6.0 23 53CF8821.02.07 (7x0.25)C 7.0 30 66

Note: The given outer diameters are maximum values and may tend toward lower tolerance limits. G = with green-yellow earth core x = without earth core

Page 4: PVC Data cables - igus.eu...122 EU04.2019 EU04.2019 123 CF240 PVC 10 x d Data cable | PVC | chainflex® CF240 Dynamic information Bend radius e-chain® linear minimum 10 x d flexible

123122 EU04

.201

9

EU04

.201

9

CF240PVC

10 x d Data cable | PVC | chainflex® CF240

Dynamic informationBend radius e-chain® linear minimum 10 x d

flexible minimum 8 x dfixed minimum 5 x d

Temperature e-chain® linear +5 °C up to +70 °Cflexible -5 °C up to +70 °C (following DIN EN 60811-504)fixed -15 °C up to +70 °C (following DIN EN 50305)

v max. unsupported 3 m/sgliding 2 m/s

a max. 20 m/s²

Travel distance Unsupported travels and up to 50 m for gliding applications, Class 4

Cable structureConductor Very finely stranded special conductors of particularly bending resistant design

made of bare copper wires.Core insulation Mechanically high-quality TPE mixture.

Core structure The individual cores are wound in layers with a short pitch length.

Core identification Colour code in accordance with DIN 47100.

Intermediate layer Foil taping over the outer layer.

Overall shield Extremely bending-resistant braiding made of tinned copper wires.Coverage approx. 70 % linear, approx. 90 % optical

Outer jacket Low-adhesion, oil-resistant PVC mixture, adapted to suit the requirements in e-chains® (following DIN EN 50363-4-1).Colour: Silver-grey (similar to RAL 7001)

Electrical informationNominal voltage 300/300 V (following DIN VDE 0298-3)

Testing voltage 1500 V (following DIN EN 50395)

Exa

mpl

e im

age

PVC iguPUR PUR TPE

EPLAN download, configurators www.igus.eu/CF240

CF240PVC

10 x d

Properties and approvalsOil resistance Oil-resistant (following DIN EN 50363-4-1), Class 2

Flame retardant According to IEC 60332-1-2, CEI 20-35, FT1, VW-1

Silicone-free Free from silicone which can affect paint adhesion (following PV 3.10.7 – status 1992)

UL/CSA Style 10493 and 2464, 300 V, 80 °C

NFPA Following NFPA 79-2018, chapter 12.9

EAC Certificate No. RU C-DE.ME77.B.01254 (TR ZU)

CTP Certificate No. C-DE.PB49.B.00416 (Fire protection)

CEI Following CEI 20-35

Lead-free Following 2011/65/EC (RoHS-II)

Clean room According to ISO Class 1, material/cable tested by IPA according to DIN EN ISO standard 14644-1

CE Following 2014/35/EU

Class 4.4.2.1

Basic requirements low 1 2 3 4 5 6 7 highest

Travel distance unsupported 1 2 3 4 5 6 ≥ 400 m

Oil resistance none 1 2 3 4 highest

Torsion none 1 2 3 4 ±360°

36 month guarantee ... 1,354 types from stock ... no cutting charges

z For medium duty applications zPVC outer jacket z Shielded zOil-resistant

z Flame retardant

10 millionDouble strokes guaranteed

10 x dBend radius, e-chain®

50 mTravel distance, e-chain®

Typical application areas z For medium duty applications, Class 4 z Unsupported travel distances and up to 50 m for gliding applications, Class 4 z Light oil influence, Class 2 z Unsupported travel distances and up to 50 m for gliding applications, Class 4 z Preferably indoor applications, but also outdoor ones at temperatures > 5 °C z Storage and retrieval units for high-bay warehouses, machining units/packaging machines, Handling, indoor cranes

Guaranteed service life (details see page 22-23)

* Higher number of double strokes? Service life calculation online www.igus.eu/chainflexlife

5 million 7.5 million 10 million

Temperature,from/to [°C]

< 10 m ≥ 10 m < 10 m ≥ 10 m < 10 m ≥ 10 m

R min. [factor x d]

R min. [factor x d]

R min. [factor x d]

R min. [factor x d]

R min. [factor x d]

R min. [factor x d]

-25/-15 12.5 15 13.5 16 14.5 17

-15/+70 10 12.5 11 13.5 12 14.5

+70/+80 12.5 15 13.5 16 14.5 17

Double strokes*

Guarantee

month guarantee

Page 5: PVC Data cables - igus.eu...122 EU04.2019 EU04.2019 123 CF240 PVC 10 x d Data cable | PVC | chainflex® CF240 Dynamic information Bend radius e-chain® linear minimum 10 x d flexible

125124 EU04

.201

9

EU04

.201

9

Example image

Data cable | PVC | chainflex® CF240

CF240PVC

10 x d

PVC iguPUR PUR TPE

EPLAN download, configurators www.igus.eu/CF240

CF240PVC

10 x d

Order example: CF240.01.03 – to your desired length (0.5 m steps)CF240 chainflex® series .01 Code nominal cross section .03 Number of cores

Online order www.chainflex.eu/CF240

Delivery time 24hrs or today.Delivery time means time until goods are shipped.

Class 4.4.2.1

Basic requirements low 1 2 3 4 5 6 7 highest

Travel distance unsupported 1 2 3 4 5 6 ≥ 400 m

Oil resistance none 1 2 3 4 highest

Torsion none 1 2 3 4 ±360°

36 month guarantee ... 1,354 types from stock ... no cutting charges

Part No.

Number of cores and conductor nominal cross section

Outer diameter (d) max.

Copper index

Weight

[mm²] [mm] [kg/km] [kg/km]CF240.01.03 (3x0.14)C 5.0 14 28CF240.01.04 (4x0.14)C 5.0 15 31CF240.01.05 (5x0.14)C 5.5 17 34CF240.01.07 (7x0.14)C 6.0 23 44CF240.01.14 (14x0.14)C 7.5 41 72CF240.01.18 (18x0.14)C 8.0 51 90CF240.01.24 (24x0.14)C 9.0 64 125CF240.02.03 (3x0.25)C 5.0 17 34CF240.02.04 (4x0.25)C 5.5 20 44CF240.02.05 (5x0.25)C 5.5 24 42CF240.02.07 (7x0.25)C 6.5 31 53CF240.02.08 (8x0.25)C 7.0 35 61CF240.02.14 (14x0.25)C 8.0 59 90CF240.02.18 (18x0.25)C 8.5 71 107CF240.02.24 (24x0.25)C 9.5 95 161CF240.03.02 (2x0.34)C 5.5 19 37CF240.03.03 (3x0.34)C 5.5 25 39CF240.03.04 (4x0.34)C 6.0 30 50CF240.03.05 (5x0.34)C 6.0 34 55CF240.03.07 (7x0.34)C 7.5 45 74CF240.03.10 (10x0.34)C 8.5 59 95CF240.03.14 (14x0.34)C 9.0 74 112CF240.03.18 (18x0.34)C 10.0 91 137CF240.03.24 (24x0.34)C 11.0 119 176

Note: The given outer diameters are maximum values and may tend toward lower tolerance limits. G = with green-yellow earth core x = without earth core

Guarantee

month guarantee

Page 6: PVC Data cables - igus.eu...122 EU04.2019 EU04.2019 123 CF240 PVC 10 x d Data cable | PVC | chainflex® CF240 Dynamic information Bend radius e-chain® linear minimum 10 x d flexible

127126 EU04

.201

9

EU04

.201

9

CF240.PURPUR

10 x d Data cable | PUR | chainflex® CF240.PUR

Dynamic informationBend radius e-chain® linear minimum 10 x d

flexible minimum 8 x dfixed minimum 5 x d

Temperature e-chain® linear -25 °C up to +80 °Cflexible -40 °C up to +80 °C (following DIN EN 60811-504)fixed -50 °C up to +80 °C (following DIN EN 50305)

v max. unsupported 3 m/sgliding 2 m/s

a max. 20 m/s²

Travel distance Unsupported travels and up to 50 m for gliding applications, Class 4

Cable structureConductor Very finely stranded special conductors of particularly bending resistant design

made of bare copper wires.Core insulation Mechanically high-quality TPE mixture.

Core structure The individual cores are wound in layers with a short pitch length.

Core identification Colour code in accordance with DIN 47100.

Intermediate layer Foil taping over the outer layer.

Overall shield Extremely bending-resistant braiding made of tinned copper wires.Coverage approx. 70 % linear, approx. 90 % optical

Outer jacket Low-adhesion, halogen-free, highly abrasion resistant PUR mixture, adapted to suit the requirements in e-chains® (following DIN EN 50363-10-2).Colour: Window-grey (similar to RAL 7040)

Electrical informationNominal voltage 300/300 V (following DIN VDE 0298-3)

Testing voltage 1500 V (following DIN EN 50395)

Exa

mpl

e im

age

PVC iguPUR PUR TPE

EPLAN download, configurators www.igus.eu/CF240.PUR

CF240.PURPUR

10 x d

Properties and approvalsUV resistance Medium

Oil resistance Oil-resistant (following DIN EN 50363-10-2), Class 3

Offshore MUD-resistant following NEK 606 - status 2009

Flame retardant According to IEC 60332-1-2, CEI 20-35, FT1, VW-1

Silicone-free Free from silicone which can affect paint adhesion (following PV 3.10.7 – status 1992)

Halogen-free Following DIN EN 60754

UL/CSA Style 10493 and 20233, 300 V, 80 °C

NFPA Following NFPA 79-2018, chapter 12.9

DNV-GL Type approval certificate No. 61 936-14 HH

EAC Certificate No. RU C-DE.ME77.B.01254 (TR ZU)

CTP Certificate No. C-DE.PB49.B.00416 (Fire protection)

CEI Following CEI 20-35

Lead-free Following 2011/65/EC (RoHS-II)

Clean room According to ISO Class 1. The outer jacket material of this series complies with CF77.UL.05.12.D - tested by IPA according to standard DIN EN ISO 14644-1

CE Following 2014/35/EU

Class 4.4.3.1

Basic requirements low 1 2 3 4 5 6 7 highest

Travel distance unsupported 1 2 3 4 5 6 ≥ 400 m

Oil resistance none 1 2 3 4 highest

Torsion none 1 2 3 4 ±360°

Guaranteed service life (details see page 22-23)

* Higher number of double strokes? Service life calculation online www.igus.eu/chainflexlife

5 million 7.5 million 10 million

Temperature,from/to [°C]

< 10 m ≥ 10 m < 10 m ≥ 10 m < 10 m ≥ 10 m

R min. [factor x d]

R min. [factor x d]

R min. [factor x d]

R min. [factor x d]

R min. [factor x d]

R min. [factor x d]

-25/-15 12.5 15 13.5 16 14.5 17

-15/+70 10 12.5 11 13.5 12 14.5

+70/+80 12.5 15 13.5 16 14.5 17

Double strokes*

36 month guarantee ... 1,354 types from stock ... no cutting charges

z For medium duty applications zPUR outer jacket z Shielded zOil resistant and coolant-resistant

z Flame retardant zPVC and halogen-free zNotch-resistant zHydrolysis and microbe-resistant

10 millionDouble strokes guaranteed

10 x dBend radius, e-chain®

50 mTravel distance, e-chain®

Typical application areas z For medium duty applications, Class 4 z Unsupported travel distances and up to 50 m for gliding applications, Class 4 z Almost unlimited resistance to oil, Class 3 z No torsion, Class 1 z Indoor and outdoor applications with average sun radiation z Machining units/machine tools, Storage and retrieval units for high-bay warehouses, Packaging industry, quick handling, refrigerating sector

Guarantee

month guarantee

New

Page 7: PVC Data cables - igus.eu...122 EU04.2019 EU04.2019 123 CF240 PVC 10 x d Data cable | PVC | chainflex® CF240 Dynamic information Bend radius e-chain® linear minimum 10 x d flexible

129128 EU04

.201

9

EU04

.201

9

Example image

Data cable | PUR | chainflex® CF240.PUR

CF240.PURPUR

10 x d

PVC iguPUR PUR TPE

EPLAN download, configurators www.igus.eu/CF240.PUR

CF240.PURPUR

10 x d

Order example: CF240.PUR.01.04 – to your desired length (0.5 m steps)CF240.PUR chainflex® series .01 Code nominal cross section .04 Number of cores

Online order www.chainflex.eu/CF240.PUR

Delivery time 24hrs or today.Delivery time means time until goods are shipped.

Class 4.4.3.1

Basic requirements low 1 2 3 4 5 6 7 highest

Travel distance unsupported 1 2 3 4 5 6 ≥ 400 m

Oil resistance none 1 2 3 4 highest

Torsion none 1 2 3 4 ±360°

36 month guarantee ... 1,354 types from stock ... no cutting charges

Part No.

Number of cores and conductor nominal cross section

Outer diameter (d) max.

Copper index

Weight

[mm²] [mm] [kg/km] [kg/km]CF240.PUR.01.04 (4x0.14)C 6.0 15 39CF240.PUR.01.07 (7x0.14)C 6.5 22 53CF240.PUR.01.08 (8x0.14)C 7.0 26 64CF240.PUR.01.14 (14x0.14)C 8.0 40 79CF240.PUR.01.18 (18x0.14)C 8.5 51 94CF240.PUR.01.25 (25x0.14)C 9.5 67 124CF240.PUR.02.03 (3x0.25)C 6.0 17 41CF240.PUR.02.04 (4x0.25)C 6.0 21 45CF240.PUR.02.05 (5x0.25)C 6.0 24 50CF240.PUR.02.07 (7x0.25)C 7.0 32 65CF240.PUR.02.08 (8x0.25)C 7.5 35 71CF240.PUR.02.14 (14x0.25)C 8.5 59 103CF240.PUR.02.18 (18x0.25)C 9.0 71 122CF240.PUR.02.25 (25x0.25)C 10.5 96 161CF240.PUR.03.03 (3x0.34)C 6.0 25 47CF240.PUR.03.04 (4x0.34)C 6.5 30 54CF240.PUR.03.05 (5x0.34)C 7.0 34 60CF240.PUR.03.07 (7x0.34)C 8.0 45 84CF240.PUR.03.14 (14x0.34)C 9.5 74 126CF240.PUR.03.18 (18x0.34)C 10.5 92 156

Note: The given outer diameters are maximum values and may tend toward lower tolerance limits. G = with green-yellow earth core x = without earth core

Guarantee

month guarantee

New

Page 8: PVC Data cables - igus.eu...122 EU04.2019 EU04.2019 123 CF240 PVC 10 x d Data cable | PVC | chainflex® CF240 Dynamic information Bend radius e-chain® linear minimum 10 x d flexible

131130 EU04

.201

9

EU04

.201

9

CF211PVC

7.5 x d Data cable | PVC | chainflex® CF211

Dynamic informationBend radius e-chain® linear minimum 7.5 x d

flexible minimum 6 x dfixed minimum 4 x d

Temperature e-chain® linear +5 °C up to +70 °Cflexible -5 °C up to +70 °C (following DIN EN 60811-504)fixed -15 °C up to +70 °C (following DIN EN 50305)

v max. unsupported 5 m/sgliding 3 m/s

a max. 50 m/s²

Travel distance Unsupported travels and up to 100 m for gliding applications, Class 5

Cable structureConductor Very finely stranded special conductors of particularly bending resistant design

made of bare copper wires.Core insulation Mechanically high-quality TPE mixture.

Core structure Cores twisted in pairs with a short pitch length, core pairs then wound with short pitch lengths.

Core identification Colour code in accordance with DIN 47100.

Intermediate layer Foil taping over the outer layer.

Overall shield Extremely bending-resistant braiding made of tinned copper wires.Coverage approx. 70 % linear, approx. 90 % optical

Outer jacket Low-adhesion, oil-resistant PVC mixture, adapted to suit the requirements in e-chains® (following DIN EN 50363-4-1).Colour: Silver-grey (similar to RAL 7001)

Electrical informationNominal voltage 300/300 V (following DIN VDE 0298-3)

Testing voltage 1500 V (following DIN EN 50395)

Exa

mpl

e im

age

PVC iguPUR PUR TPE

EPLAN download, configurators www.igus.eu/CF211

CF211PVC

7.5 x d

Properties and approvalsOil resistance Oil-resistant (following DIN EN 50363-4-1), Class 2

Flame retardant According to IEC 60332-1-2, CEI 20-35, FT1, VW-1

Silicone-free Free from silicone which can affect paint adhesion (following PV 3.10.7 – status 1992)

UL/CSA Style 10493 and 2464, 300 V, 80 °C

NFPA Following NFPA 79-2018, chapter 12.9

EAC Certificate No. RU C-DE.ME77.B.01254 (TR ZU)

CTP Certificate No. C-DE.PB49.B.00416 (Fire protection)

CEI Following CEI 20-35

Lead-free Following 2011/65/EC (RoHS-II)

Clean room According to ISO Class 1. The outer jacket material of this series complies with CF240.02.24 - tested by IPA according to standard DIN EN ISO 14644-1

CE Following 2014/35/EU

Class 5.5.2.1

Basic requirements low 1 2 3 4 5 6 7 highest

Travel distance unsupported 1 2 3 4 5 6 ≥ 400 m

Oil resistance none 1 2 3 4 highest

Torsion none 1 2 3 4 ±360°

Guaranteed service life (details see page 22-23)

* Higher number of double strokes? Service life calculation online www.igus.eu/chainflexlife

5 million 7.5 million 10 million

Temperature,from/to [°C]

R min. [factor x d]

R min. [factor x d]

R min. [factor x d]

+5/+15 10 11 12

+15/+60 7.5 8.5 9.5

+60/+70 10 11 12

Double strokes*

36 month guarantee ... 1,354 types from stock ... no cutting charges

z For heavy duty applications zPVC outer jacket z Shielded z Twisted pair

zOil-resistant z Flame retardant

10 millionDouble strokes guaranteed

7.5 x dBend radius, e-chain®

100 mTravel distance, e-chain®

Typical application areas z For heavy duty applications, Class 5 z Unsupported travel distances and up to 100 m for gliding applications, Class 5 z Light oil influence, Class 2 z Storage and retrieval units for high-bay warehouses, machining units/packaging machines, Handling, indoor cranes

z Preferably indoor applications, but also outdoor ones at temperatures > 5 °C z No torsion, Class 1

Guarantee

month guarantee

Page 9: PVC Data cables - igus.eu...122 EU04.2019 EU04.2019 123 CF240 PVC 10 x d Data cable | PVC | chainflex® CF240 Dynamic information Bend radius e-chain® linear minimum 10 x d flexible

133132 EU04

.201

9

EU04

.201

9

Example image

Data cable | PVC | chainflex® CF211

CF211PVC

7.5 x d

PVC iguPUR PUR TPE

EPLAN download, configurators www.igus.eu/CF211

CF211PVC

7.5 x d

Order example: CF211.02.01.02 – to your desired length (0.5 m steps)CF211 chainflex® series .02 Code nominal cross section .01 Number of pairs .02 Identification pairs

Online order www.chainflex.eu/CF211

Delivery time 24hrs or today.Delivery time means time until goods are shipped.

Class 5.5.2.1

Basic requirements low 1 2 3 4 5 6 7 highest

Travel distance unsupported 1 2 3 4 5 6 ≥ 400 m

Oil resistance none 1 2 3 4 highest

Torsion none 1 2 3 4 ±360°

36 month guarantee ... 1,354 types from stock ... no cutting charges

Part No.

Number of cores and conductor nominal cross section

Outer diameter (d) max.

Copper index

Weight

[mm²] [mm] [kg/km] [kg/km]CF211.02.01.02 (2x0.25)C 5.0 16 31CF211.02.02.02 2) (2x(2x0.25))C 6.0 23 41CF211.02.03.02 (3x(2x0.25))C 7.0 32 67CF211.02.04.02 (4x(2x0.25))C 8.0 40 72CF211.02.05.02 (5x(2x0.25))C 8.5 48 87CF211.02.06.02 (6x(2x0.25))C 9.0 56 103CF211.02.08.02 (8x(2x0.25))C 10.5 70 138CF211.02.10.02 (10x(2x0.25))C 12.0 90 169CF211.02.14.02 (14x(2x0.25))C 12.0 108 189CF211.03.03.02 (3x(2x0.34))C 8.0 44 81CF211.03.08.02 (8x(2x0.34))C 11.5 91 169CF211.03.10.02 (10x(2x0.34))C 13.0 111 190CF211.05.01.02 (2x0.5)C 5.5 24 41CF211.05.02.02 2) (2x(2x0.5))C 7.0 37 62CF211.05.03.02 (3x(2x0.5))C 9.0 55 103CF211.05.04.02 (4x(2x0.5))C 9.5 67 128CF211.05.05.02 (5x(2x0.5))C 10.5 83 149CF211.05.06.02 (6x(2x0.5))C 11.5 91 174CF211.05.08.02 (8x(2x0.5))C 13.0 125 224CF211.05.10.02 (10x(2x0.5))C 15.5 170 283CF211.05.14.02 (14x(2x0.5))C 15.5 187 288The chainflex® types marked with 2) are cables designed as a star-quad.Note: The given outer diameters are maximum values and may tend toward lower tolerance limits. G = with green-yellow earth core x = without earth core

Guarantee

month guarantee

Page 10: PVC Data cables - igus.eu...122 EU04.2019 EU04.2019 123 CF240 PVC 10 x d Data cable | PVC | chainflex® CF240 Dynamic information Bend radius e-chain® linear minimum 10 x d flexible

135134 EU04

.201

9

EU04

.201

9

CF211.PURPUR

7.5 x d Data cable | PUR | chainflex® CF211.PUR

Dynamic informationBend radius e-chain® linear minimum 7.5 x d

flexible minimum 6 x dfixed minimum 4 x d

Temperature e-chain® linear -25 °C up to +80 °Cflexible -40 °C up to +80 °C (following DIN EN 60811-504)fixed -50 °C up to +80 °C (following DIN EN 50305)

v max. unsupported 5 m/sgliding 3 m/s

a max. 50 m/s²

Travel distance Unsupported travels and up to 100 m for gliding applications, Class 5

Cable structureConductor Very finely stranded special conductors of particularly bending resistant design

made of bare copper wires.Core insulation Mechanically high-quality TPE mixture.

Core structure Cores twisted in pairs with a short pitch length, core pairs then wound with short pitch lengths.

Core identification Colour code in accordance with DIN 47100.

Intermediate layer Foil taping over the outer layer.

Overall shield Extremely bending-resistant braiding made of tinned copper wires.Coverage approx. 70 % linear, approx. 90 % optical

Outer jacket Low-adhesion, halogen-free, highly abrasion resistant PUR mixture, adapted to suit the requirements in e-chains® (following DIN EN 50363-10-2).Colour: Window-grey (similar to RAL 7040)

Electrical informationNominal voltage 300/300 V (following DIN VDE 0298-3)

Testing voltage 1500 V (following DIN EN 50395)

Exa

mpl

e im

age

PVC iguPUR PUR TPE

EPLAN download, configurators www.igus.eu/CF211.PUR

CF211.PURPUR

7.5 x d

Properties and approvalsUV resistance Medium

Oil resistance Oil-resistant (following DIN EN 50363-10-2), Class 3

Offshore MUD-resistant following NEK 606 - status 2009

Flame retardant According to IEC 60332-1-2, CEI 20-35, FT1, VW-1

Silicone-free Free from silicone which can affect paint adhesion (following PV 3.10.7 – status 1992)

Halogen-free Following DIN EN 60754

UL/CSA Style 10493 and 20233, 300 V, 80 °C

NFPA Following NFPA 79-2018, chapter 12.9

DNV-GL Type approval certificate No. 13 656-14 HH

EAC Certificate No. RU C-DE.ME77.B.01254 (TR ZU)

CTP Certificate No. C-DE.PB49.B.00449 (Fire protection)

CEI Following CEI 20-35

Lead-free Following 2011/65/EC (RoHS-II)

Clean room According to ISO Class 1. The outer jacket material of this series complies with CF77.UL.05.12.D - tested by IPA according to standard DIN EN ISO 14644-1

CE Following 2014/35/EU

Class 5.5.3.1

Basic requirements low 1 2 3 4 5 6 7 highest

Travel distance unsupported 1 2 3 4 5 6 ≥ 400 m

Oil resistance none 1 2 3 4 highest

Torsion none 1 2 3 4 ±360°

Guaranteed service life (details see page 22-23)

* Higher number of double strokes? Service life calculation online www.igus.eu/chainflexlife

5 million 7.5 million 10 million

Temperature,from/to [°C]

R min. [factor x d]

R min. [factor x d]

R min. [factor x d]

-25/-15 10 11 12

-15/+70 7.5 8.5 9.5

+70/+80 10 11 12

Double strokes*

36 month guarantee ... 1,354 types from stock ... no cutting charges

z For heavy duty applications zPUR outer jacket z Shielded, twisted pair zOil resistant and coolant-resistant

z Flame retardant zPVC and halogen-free zNotch-resistant zHydrolysis and microbe-resistant

10 millionDouble strokes guaranteed

7.5 x dBend radius, e-chain®

100 mTravel distance, e-chain®

Typical application areas z For heavy duty applications, Class 5 z Unsupported travel distances and up to 100 m for gliding applications, Class 5 z Almost unlimited resistance to oil, Class 3 z No torsion, Class 1 z Indoor and outdoor applications with average sun radiation z Machining units/machine tools, Storage and retrieval units for high-bay warehouses, Packaging industry, quick handling, refrigerating sector

Guarantee

month guarantee

Page 11: PVC Data cables - igus.eu...122 EU04.2019 EU04.2019 123 CF240 PVC 10 x d Data cable | PVC | chainflex® CF240 Dynamic information Bend radius e-chain® linear minimum 10 x d flexible

137136 EU04

.201

9

EU04

.201

9

Example image

Data cable | PUR | chainflex® CF211.PUR

CF211.PURPUR

7.5 x d

PVC iguPUR PUR TPE

EPLAN download, configurators www.igus.eu/CF211.PUR

CF211.PURPUR

7.5 x d

Order example: CF211.PUR.02.01.02 – to your desired length (0.5 m steps)CF211.PUR chainflex® series .02 Code nominal cross section .01 Number of pairs .02 Identification pairs

Online order www.chainflex.eu/CF211.PUR

Delivery time 24hrs or today.Delivery time means time until goods are shipped.

Class 5.5.3.1

Basic requirements low 1 2 3 4 5 6 7 highest

Travel distance unsupported 1 2 3 4 5 6 ≥ 400 m

Oil resistance none 1 2 3 4 highest

Torsion none 1 2 3 4 ±360°

36 month guarantee ... 1,354 types from stock ... no cutting charges

Part No.

Number of cores and conductor nominal cross section

Outer diameter (d) max.

Copper index

Weight

[mm²] [mm] [kg/km] [kg/km]CF211.PUR.02.01.02 (2x0.25)C 5.0 16 29CF211.PUR.02.02.02 2) (2x(2x0.25))C 6.0 23 38CF211.PUR.02.03.02 (3x(2x0.25))C 7.0 32 62CF211.PUR.02.04.02 (4x(2x0.25))C 7.5 40 65CF211.PUR.02.05.02 (5x(2x0.25))C 8.5 48 81CF211.PUR.02.06.02 (6x(2x0.25))C 9.0 56 97CF211.PUR.02.08.02 (8x(2x0.25))C 10.5 70 124CF211.PUR.02.10.02 (10x(2x0.25))C 12.0 90 155CF211.PUR.02.14.02 (14x(2x0.25))C 12.0 108 175CF211.PUR.03.03.02 (3x(2x0.34))C 8.0 44 81CF211.PUR.03.08.02 (8x(2x0.34))C 12.0 91 147CF211.PUR.05.01.02 (2x0.5)C 5.5 24 40CF211.PUR.05.02.02 2) (2x(2x0.5))C 7.0 37 59CF211.PUR.05.03.02 (3x(2x0.5))C 9.0 55 98CF211.PUR.05.04.02 (4x(2x0.5))C 9.5 67 118CF211.PUR.05.05.02 (5x(2x0.5))C 10.5 83 149CF211.PUR.05.06.02 (6x(2x0.5))C 11.5 91 174CF211.PUR.05.08.02 (8x(2x0.5))C 13.0 125 211CF211.PUR.05.10.02 (10x(2x0.5))C 15.0 170 265CF211.PUR.05.14.02 (14x(2x0.5))C 15.0 187 288The chainflex® types marked with 2) are cables designed as a star-quad.Note: The given outer diameters are maximum values and may tend toward lower tolerance limits. G = with green-yellow earth core x = without earth core

Guarantee

month guarantee

Page 12: PVC Data cables - igus.eu...122 EU04.2019 EU04.2019 123 CF240 PVC 10 x d Data cable | PVC | chainflex® CF240 Dynamic information Bend radius e-chain® linear minimum 10 x d flexible

139138 EU04

.201

9

EU04

.201

9

CF11TPE

6.8 x d Data cable | TPE | chainflex® CF11

Dynamic informationBend radius e-chain® linear minimum 6.8 x d

flexible minimum 5 x dfixed minimum 4 x d

Temperature e-chain® linear -35 °C up to +100 °Cflexible -50 °C up to +100 °C (following DIN EN 60811-504)fixed -55 °C up to +100 °C (following DIN EN 50305)

v max. unsupported 10 m/sgliding 6 m/s

a max. 100 m/s²

Travel distance Unsupported travel distances and up to 400 m and more for gliding applica-tions, Class 6

Cable structureConductor Stranded conductor in especially bending-resistant version consisting of bare

copper wires (following DIN EN 60228).Core insulation Mechanically high-quality TPE mixture.

Core structure Cores twisted in pairs with a short pitch length, core pairs then wound with short pitch lengths.

Core identification Cores < 1.0 mm²: Colour code in accordance with DIN 47100.Cores ≥ 1.0 mm²: Black cores with white numbers.

Inner jacket TPE mixture adapted to suit the requirements in e-chains®.

Overall shield Extremely bending-resistant braiding made of tinned copper wires.Coverage approx. 70 % linear, approx. 90 % optical

Outer jacket Low-adhesion, extremely abrasion-resistant and highly flexible TPE mixture, adapted to suit the requirements in e-chains®.Colour: Steel-blue (similar to RAL 5011)

Electrical informationNominal voltage 300/300 V (following DIN VDE 0298-3)

Testing voltage 1500 V (following DIN EN 50395)

Exa

mpl

e im

age

PVC iguPUR PUR TPE

EPLAN download, configurators www.igus.eu/CF11

CF11TPE

6.8 x d

Properties and approvalsUV resistance High

Oil resistance Oil resistant (following DIN EN 60811-404), bio-oil resistant (following VDMA 24568 with Plantocut 8 S-MB tested by DEA), Class 4

Silicone-free Free from silicone which can affect paint adhesion (following PV 3.10.7 – status 1992)

Halogen-free Following DIN EN 60754

EAC Certificate No. RU C-DE.ME77.B.01254 (TR ZU)

Lead-free Following 2011/65/EC (RoHS-II)

Clean room According to ISO Class 1. The outer jacket material of this series complies with CF9.15.07 - tested by IPA according to standard DIN EN ISO 14644-1

CE Following 2014/35/EU

Class 6.6.4.1

Basic requirements low 1 2 3 4 5 6 7 highest

Travel distance unsupported 1 2 3 4 5 6 ≥ 400 m

Oil resistance none 1 2 3 4 highest

Torsion none 1 2 3 4 ±360°

Guaranteed service life (details see page 22-23)

* Higher number of double strokes? Service life calculation online www.igus.eu/chainflexlife

5 million 7.5 million 10 million

Temperature,from/to [°C]

R min. [factor x d]

R min. [factor x d]

R min. [factor x d]

-35/-25 7.5 8.5 9.5

-25/+90 6.8 7.5 8.5

+90/+100 7.5 8.5 9.5

Double strokes*

36 month guarantee ... 1,354 types from stock ... no cutting charges

z For extremely heavy duty applications z TPE outer jacket z Shielded z Twisted pair

zOil and bio-oil resistant zPVC and halogen-free zHydrolysis and microbe-resistant

10 millionDouble strokes guaranteed

6.8 x dBend radius, e-chain®

400 mTravel distance, e-chain®

Typical application areas z For extremely heavy duty applications, Class 6 z Unsupported travel distances and up to 400 m and more for gliding applications, Class 6 z Almost unlimited resistance to oil, also with bio-oils, Class 4 z No torsion, Class 1 z Indoor and outdoor applications, UV-resistant z Storage and retrieval units for high-bay warehouses, Machining units/machine tools, quick handling, Clean room, semiconductor insertion, outdoor cranes, low temperature applications

Guarantee

month guarantee

Page 13: PVC Data cables - igus.eu...122 EU04.2019 EU04.2019 123 CF240 PVC 10 x d Data cable | PVC | chainflex® CF240 Dynamic information Bend radius e-chain® linear minimum 10 x d flexible

141140 EU04

.201

9

EU04

.201

9

Example image

Data cable | TPE | chainflex® CF11

CF11TPE

6.8 x d

PVC iguPUR PUR TPE

EPLAN download, configurators www.igus.eu/CF11

CF11TPE

6.8 x d

Order example: CF11.01.04.02 – to your desired length (0.5 m steps)CF11 chainflex® series .01 Code nominal cross section .04 Number of pairs .02 Identification pairs

Online order www.chainflex.eu/CF11

Delivery time 24hrs or today.Delivery time means time until goods are shipped.

Class 6.6.4.1

Basic requirements low 1 2 3 4 5 6 7 highest

Travel distance unsupported 1 2 3 4 5 6 ≥ 400 m

Oil resistance none 1 2 3 4 highest

Torsion none 1 2 3 4 ±360°

36 month guarantee ... 1,354 types from stock ... no cutting charges

Part No.

Number of cores and conductor nominal cross section

Outer diameter (d) max.

Copper index

Weight

[mm²] [mm] [kg/km] [kg/km]CF11.01.04.02 (4x(2x0.14))C 7.5 30 64CF11.01.18.02 (18x(2x0.14))C 12.0 101 192CF11.02.01.02 (2x0.25)C 6.0 17 38CF11.02.02.02 2) (2x(2x0.25))C 6.5 26 49CF11.02.03.02 (3x(2x0.25))C 8.0 35 78CF11.02.04.02 (4x(2x0.25))C 8.5 42 89CF11.02.05.02 (5x(2x0.25))C 9.0 49 104CF11.02.06.02 (6x(2x0.25))C 10.0 69 130CF11.02.10.02 (10x(2x0.25))C 13.0 103 217CF11.02.14.02 (14x(2x0.25))C 13.5 124 224CF11.03.08.02 (8x(2x0.34))C 13.0 106 220CF11.05.04.02 (4x(2x0.5))C 9.5 77 133CF11.05.06.02 (6x(2x0.5))C 12.0 103 198CF11.05.08.02 (8x(2x0.5))C 14.0 135 261CF11.07.03.02 (3x(2x0.75))C 10.0 83 155CF11.10.04.02 (4x(2x1.0))C 12.0 125 228CF11.15.06.02 (6x(2x1.5))C 17.0 247 411The chainflex® types marked with 2) are cables designed as a star-quad.Note: The given outer diameters are maximum values and may tend toward lower tolerance limits. G = with green-yellow earth core x = without earth core

Guarantee

month guarantee

Page 14: PVC Data cables - igus.eu...122 EU04.2019 EU04.2019 123 CF240 PVC 10 x d Data cable | PVC | chainflex® CF240 Dynamic information Bend radius e-chain® linear minimum 10 x d flexible

143142 EU04

.201

9

EU04

.201

9

CF112PUR

10 x d Data cable | PUR | chainflex® CF112

Dynamic informationBend radius e-chain® linear minimum 10 x d

flexible minimum 8 x dfixed minimum 5 x d

Temperature e-chain® linear -25 °C up to +80 °Cflexible -40 °C up to +80 °C (following DIN EN 60811-504)fixed -50 °C up to +80 °C (following DIN EN 50305)

v max. unsupported 10 m/sgliding 5 m/s

a max. 80 m/s²

Travel distance Unsupported travels and up to 100 m for gliding applications, Class 5

Cable structureConductor Very finely stranded special conductors of particularly bending resistant design

made of bare copper wires.Core insulation Mechanically high-quality TPE mixture.

Core structure Cores twisted in pairs with a short pitch length, core pairs then wound with short pitch lengths.

Core identification Colour code in accordance with DIN 47100.

Element shield Extremely bending-resistant braiding made of tinned copper wires.Coverage approx. 70 % linear, approx. 90 % optical

Inner jacket TPE mixture adapted to suit the requirements in e-chains®.

Overall shield Extremely bending-resistant braiding made of tinned copper wires.Coverage approx. 70 % linear, approx. 90 % optical

Outer jacket Low-adhesion, extremely abrasion-resistant and highly flexible TPE mixture, adapted to suit the requirements in e-chains®.Colour: Anthracite grey (similar to RAL 7016)

Electrical informationNominal voltage 300/300 V (following DIN VDE 0298-3)

Testing voltage 1500 V (following DIN EN 50395)

Exa

mpl

e im

age

PVC iguPUR PUR TPE

EPLAN download, configurators www.igus.eu/CF112

CF112PUR

10 x d

Properties and approvalsUV resistance High

Oil resistance Oil-resistant (following DIN EN 50363-10-2), Class 3

Offshore MUD-resistant following NEK 606 - status 2009

Flame retardant According to IEC 60332-1-2, CEI 20-35, FT1, VW-1

Silicone-free Free from silicone which can affect paint adhesion (following PV 3.10.7 – status 1992)

Halogen-free Following DIN EN 60754

UL/CSA Style 10493 and 20233, 300 V, 80 °C

NFPA Following NFPA 79-2018, chapter 12.9

DNV-GL Type approval certificate No. 13 656-14 HH

EAC Certificate No. RU C-DE.ME77.B.01254 (TR ZU)

CTP Certificate No. C-DE.PB49.B.00416 (Fire protection)

CEI Following CEI 20-35

Lead-free Following 2011/65/EC (RoHS-II)

Clean room According to ISO Class 1. The outer jacket material of this series complies with CF77.UL.05.12.D - tested by IPA according to standard DIN EN ISO 14644-1

CE Following 2014/35/EU

Class 6.5.3.1

Basic requirements low 1 2 3 4 5 6 7 highest

Travel distance unsupported 1 2 3 4 5 6 ≥ 400 m

Oil resistance none 1 2 3 4 highest

Torsion none 1 2 3 4 ±360°

Guaranteed service life (details see page 22-23)

* Higher number of double strokes? Service life calculation online www.igus.eu/chainflexlife

5 million 7.5 million 10 million

Temperature,from/to [°C]

R min. [factor x d]

R min. [factor x d]

R min. [factor x d]

-25/-15 12.5 13.5 14.5

-15/+70 10 11 12

+70/+80 12.5 13.5 14.5

Double strokes*

36 month guarantee ... 1,354 types from stock ... no cutting charges

z For extremely heavy duty applications zPUR outer jacket zDouble shielded, twisted pair zOil resistant and coolant-resistant

z Flame retardant zPVC and halogen-free zNotch-resistant zHydrolysis and microbe-resistant

10 millionDouble strokes guaranteed

10 x dBend radius, e-chain®

100 mTravel distance, e-chain®

Typical application areas z For heaviest duty applications, Class 6 z Unsupported travel distances and up to 100 m for gliding applications, Class 5 z Almost unlimited resistance to oil, Class 3 z No torsion, Class 1 z Indoor and outdoor applications with average sun radiation z Machining units/machine tools, Storage and retrieval units for high-bay warehouses, Packaging industry, quick handling, refrigerating sector

Guarantee

month guarantee

Page 15: PVC Data cables - igus.eu...122 EU04.2019 EU04.2019 123 CF240 PVC 10 x d Data cable | PVC | chainflex® CF240 Dynamic information Bend radius e-chain® linear minimum 10 x d flexible

145144 EU04

.201

9

EU04

.201

9

Example image

Data cable | PUR | chainflex® CF112

CF112PUR

10 x d

PVC iguPUR PUR TPE

EPLAN download, configurators www.igus.eu/CF112

CF112PUR

10 x d

Order example: CF112.02.02.02 – to your desired length (0.5 m steps)CF112 chainflex® series .02 Code nominal cross section .02 Number of pairs .02 Identification pairs

Online order www.chainflex.eu/CF112

Delivery time 24hrs or today.Delivery time means time until goods are shipped.

Class 6.5.3.1

Basic requirements low 1 2 3 4 5 6 7 highest

Travel distance unsupported 1 2 3 4 5 6 ≥ 400 m

Oil resistance none 1 2 3 4 highest

Torsion none 1 2 3 4 ±360°

36 month guarantee ... 1,354 types from stock ... no cutting charges

Part No.

Number of cores and conductor nominal cross section

Outer diameter (d) max.

Copper index

Weight

[mm²] [mm] [kg/km] [kg/km]CF112.02.02.02 (2x(2x0.25)C)C 9.5 56 128CF112.02.03.02 (3x(2x0.25)C)C 10.0 71 147CF112.02.04.02 (4x(2x0.25)C)C 11.0 81 163CF112.02.05.02 (5x(2x0.25)C)C 11.5 99 188CF112.05.02.02 (2x(2x0.5)C)C 11.5 75 171CF112.05.04.02 (4x(2x0.5)C)C 13.0 116 225CF112.05.06.02 (6x(2x0.5)C)C 14.5 160 312Note: The given outer diameters are maximum values and may tend toward lower tolerance limits. G = with green-yellow earth core x = without earth core

Guarantee

month guarantee

Page 16: PVC Data cables - igus.eu...122 EU04.2019 EU04.2019 123 CF240 PVC 10 x d Data cable | PVC | chainflex® CF240 Dynamic information Bend radius e-chain® linear minimum 10 x d flexible

147146 EU04

.201

9

EU04

.201

9

CF12TPE

10 x d Data cable | TPE | chainflex® CF12

Dynamic informationBend radius e-chain® linear minimum 10 x d

flexible minimum 8 x dfixed minimum 5 x d

Temperature e-chain® linear -35 °C up to +100 °Cflexible -50 °C up to +100 °C (following DIN EN 60811-504)fixed -55 °C up to +100 °C (following DIN EN 50305)

v max. unsupported 10 m/sgliding 6 m/s

a max. 100 m/s²

Travel distance Unsupported travel distances and up to 400 m and more for gliding applica-tions, Class 6

Cable structureConductor Stranded conductor in especially bending-resistant version consisting of bare

copper wires (following DIN EN 60228).Core insulation Mechanically high-quality TPE mixture.

Core structure Cores twisted in pairs with a short pitch length, core pairs then wound with short pitch lengths.

Core identification Cores < 0.5 mm²: Colour code in accordance with DIN 47100.Cores ≥ 0.5 mm²: Black cores with white numbers.

Element shield Extremely bending-resistant braiding made of tinned copper wires.Coverage approx. 70 % linear, approx. 90 % optical

Element jacket TPE mixture on pair shielding adapted to suit the requirements in e-chains®.

Inner jacket TPE mixture adapted to suit the requirements in e-chains®.

Overall shield Highly flexible shield consisting of galvanized steel wire braid.Coverage approx. 70 % linear, approx. 90 % optical

Outer jacket Low-adhesion, extremely abrasion-resistant and highly flexible TPE mixture, adapted to suit the requirements in e-chains®.Colour: Steel-blue (similar to RAL 5011)

Electrical informationNominal voltage 300/300 V (following DIN VDE 0298-3)

Testing voltage 1500 V (following DIN EN 50395)

Exa

mpl

e im

age

PVC iguPUR PUR TPE

EPLAN download, configurators www.igus.eu/CF12

CF12TPE

10 x d

Properties and approvalsUV resistance High

Oil resistance Oil resistant (following DIN EN 60811-404), bio-oil resistant (following VDMA 24568 with Plantocut 8 S-MB tested by DEA), Class 4

Silicone-free Free from silicone which can affect paint adhesion (following PV 3.10.7 – status 1992)

Halogen-free Following DIN EN 60754

EAC Certificate No. RU C-DE.ME77.B.01254 (TR ZU)

Lead-free Following 2011/65/EC (RoHS-II)

Clean room According to ISO Class 1. The outer jacket material of this series complies with CF9.15.07 - tested by IPA according to standard DIN EN ISO 14644-1

CE Following 2014/35/EU

Class 6.6.4.1

Basic requirements low 1 2 3 4 5 6 7 highest

Travel distance unsupported 1 2 3 4 5 6 ≥ 400 m

Oil resistance none 1 2 3 4 highest

Torsion none 1 2 3 4 ±360°

Guaranteed service life (details see page 22-23)

* Higher number of double strokes? Service life calculation online www.igus.eu/chainflexlife

5 million 7.5 million 10 million

Temperature,from/to [°C]

R min. [factor x d]

R min. [factor x d]

R min. [factor x d]

-35/-25 12.5 13.5 14.5

-25/+90 10 11 12

+90/+100 12.5 13.5 14.5

Double strokes*

36 month guarantee ... 1,354 types from stock ... no cutting charges

z For extremely heavy duty applications z TPE outer jacket zDouble-shielded zOil and bio-oil resistant

zPVC and halogen-free zHydrolysis and microbe-resistant

10 millionDouble strokes guaranteed

10 x dBend radius, e-chain®

400 mTravel distance, e-chain®

Typical application areas z For heaviest duty applications, Class 6 z Unsupported travel distances and up to 400 m and more for gliding applications, Class 6 z Almost unlimited resistance to oil, also with bio-oils, Class 4 z No torsion, Class 1 z Indoor and outdoor applications, UV-resistant z For maximum EMC protection z Storage and retrieval units for high-bay warehouses, Machining units/machine tools, quick handling, Clean room, semiconductor insertion, outdoor cranes, low temperature applications

Part No.

Number of cores and conductor nominal cross section

Outer diameter (d) max.

Copper index

Weight

[mm²] [mm] [kg/km] [kg/km]CF12.02.04.02 (4x(2x0.25)C)C 11.0 51 174CF12.05.03.02 (3x(2x0.5)C)C 13.5 65 228CF12.05.04.02 (4x(2x0.5)C)C 14.5 83 266CF12.05.06.02 (6x(2x0.5)C)C 17.0 128 388CF12.05.08.02 (8x(2x0.5)C)C 20.5 163 516CF12.05.10.02 (10x(2x0.5)C)C 23.0 203 600CF12.05.14.02 (14x(2x0.5)C)C 23.0 297 705CF12.10.06.02 (6x(2x1.0)C)C 20.0 198 537Note: The given outer diameters are maximum values and may tend toward lower tolerance limits. G = with green-yellow earth core x = without earth core

Guarantee

month guarantee

Page 17: PVC Data cables - igus.eu...122 EU04.2019 EU04.2019 123 CF240 PVC 10 x d Data cable | PVC | chainflex® CF240 Dynamic information Bend radius e-chain® linear minimum 10 x d flexible

149148 EU04

.201

9

EU04

.201

9

CF298TPE4 x d Data cable | TPE | chainflex® CF298

Dynamic informationBend radius e-chain® linear minimum 4 x d

flexible minimum 4 x dfixed minimum 3 x d

Temperature e-chain® linear -35 °C up to +90 °Cflexible -50 °C up to +90 °C (following DIN EN 60811-504)fixed -55 °C up to +90 °C (following DIN EN 50305)

v max. unsupported 10 m/sgliding 6 m/s

a max. 100 m/s2

Travel distance Short, very fast applications with small radii and restricted installation space, Class 5

Torsion ± 90°, with 1 m cable length, Class 2

Cable structureConductor Conductor consisting of a highly flexible special alloy.

Core insulation Mechanically high-quality TPE mixture.

Core structure Cores wound in a layer with especially short pitch length.

Core identification Colour code in accordance with DIN 47100.CF298.02.03: brown, blue, blackCF298.03.04: brown, blue, black, white

Outer jacket Low-adhesion, extremely abrasion-resistant and highly flexible TPE mixture, adapted to suit the requirements in e-chains®.Colour: Steel-blue (similar to RAL 5011)

Electrical informationNominal voltage 300/300 V

Testing voltage 1500 V

Exa

mpl

e im

age

PVC iguPUR PUR TPE

EPLAN download, configurators www.igus.eu/CF298

CF298TPE4 x d

Properties and approvalsUV resistance High

Oil resistance Oil resistant (following DIN EN 60811-404), bio-oil resistant (following VDMA 24568 with Plantocut 8 S-MB tested by DEA), Class 4

Silicone-free Free from silicone which can affect paint adhesion (following PV 3.10.7 – status 1992)

Halogen-free Following DIN EN 60754

EAC Certificate No. RU C-DE.ME77.B.02806 (TR ZU)

Lead-free Following 2011/65/EC (RoHS-II)

Clean room According to ISO Class 1. The outer jacket material of this series complies with CF9.15.07 - tested by IPA according to standard DIN EN ISO 14644-1

CE Following 2014/35/EU

Class 7.5.4.2

Basic requirements low 1 2 3 4 5 6 7 highest

Travel distance unsupported 1 2 3 4 5 6 ≥ 400 m

Oil resistance none 1 2 3 4 highest

Torsion none 1 2 3 4 ±360°

Guaranteed service life (details see page 22-23)

* Higher number of double strokes? Service life calculation online www.igus.eu/chainflexlife

10 million 15 million 20 million

Temperature,from/to [°C]

R min. [factor x d] R min. [factor x d] R min. [factor x d]

-35/-25 5 6 7

-25/+80 4 5 6

+80/+90 5 6 7

Double strokes*

36 month guarantee ... 1,354 types from stock ... no cutting charges

Note: The given outer diameters are maximum values and may tend toward lower tolerance limits. G = with green-yellow earth core x = without earth core

z For heaviest duty applications and especially small radii down to 4 x d z TPE outer jacket zOil and bio-oil resistant

zPVC and halogen-free z Low-temperature-flexible zHydrolysis and microbe-resistant

20 millionDouble strokes guaranteed

4 x dBend radius, e-chain®

100 mTravel distance, e-chain®

Typical application areas z For heaviest duty applications and especially small radii down to 4 x d, Class 7 z Especially for short, very fast applications with small radii and restricted installation space, Class 5 z Almost unlimited resistance to oil, also with bio-oils, Class 4 z Torsion ± 90°, with 1 m cable length, Class 2 z Indoor and outdoor applications, UV-resistant z Pick and place machines, automatic doors, Clean room, very quick handling

Part No.

Number of cores and conductor nominal cross section

Outer diameter (d) max.

Copper index

Weight

[mm²] [mm] [kg/km] [kg/km]CF298.01.02 2x0.14 4.5 5 15CF298.01.04 4x0.14 5.5 9 25CF298.01.08 8x0.14 7.0 16 44CF298.02.03 3x0.25 5.5 12 28CF298.02.04 4x0.25 6.0 16 35CF298.02.07 7x0.25 7.0 28 53CF298.02.08 8x0.25 7.5 32 61CF298.03.04 4x0.34 6.0 19 37CF298.03.07 7x0.34 7.5 33 62CF298.05.04 4x0.5 6.5 27 48

Guarantee

month guarantee

Page 18: PVC Data cables - igus.eu...122 EU04.2019 EU04.2019 123 CF240 PVC 10 x d Data cable | PVC | chainflex® CF240 Dynamic information Bend radius e-chain® linear minimum 10 x d flexible

151150 EU04

.201

9

EU04

.201

9

CF299TPE4 x d Data cable | TPE | chainflex® CF299

Dynamic informationBend radius e-chain® linear minimum 4 x d

flexible minimum 4 x dfixed minimum 3 x d

Temperature e-chain® linear -35 °C up to +90 °Cflexible -50 °C up to +90 °C (following DIN EN 60811-504)fixed -55 °C up to +90 °C (following DIN EN 50305)

v max. unsupported 10 m/sgliding 6 m/s

a max. 100 m/s2

Travel distance Short, very fast applications with small radii and restricted installation space, Class 5

Cable structureConductor Conductor consisting of a highly flexible special alloy.

Core insulation Mechanically high-quality TPE mixture.

Core structure Cores wound in a layer with especially short pitch length.

Core identification Colour code in accordance with DIN 47100.

Inner jacket TPE mixture adapted to suit the requirements in e-chains®.

Overall shield Extremely bending resistant braiding made of alloy wires.Coverage approx. 70 % linear, approx. 90 % optical

Outer jacket Low-adhesion, extremely abrasion-resistant and highly flexible TPE mixture, adapted to suit the requirements in e-chains®.Colour: Steel-blue (similar to RAL 5011)

Electrical informationNominal voltage 300/300 V

Testing voltage 1500 V

Exa

mpl

e im

age

PVC iguPUR PUR TPE

EPLAN download, configurators www.igus.eu/CF299

CF299TPE4 x d

Properties and approvalsUV resistance High

Oil resistance Oil resistant (following DIN EN 60811-404), bio-oil resistant (following VDMA 24568 with Plantocut 8 S-MB tested by DEA), Class 4

Silicone-free Free from silicone which can affect paint adhesion (following PV 3.10.7 – status 1992)

Halogen-free Following DIN EN 60754

EAC Certificate No. RU C-DE.ME77.B.02806 (TR ZU)

Lead-free Following 2011/65/EC (RoHS-II)

Clean room According to ISO Class 1. The outer jacket material of this series complies with CF9.15.07 - tested by IPA according to standard DIN EN ISO 14644-1

CE Following 2014/35/EU

Class 7.5.4.1

Basic requirements low 1 2 3 4 5 6 7 highest

Travel distance unsupported 1 2 3 4 5 6 ≥ 400 m

Oil resistance none 1 2 3 4 highest

Torsion none 1 2 3 4 ±360°

Guaranteed service life (details see page 22-23)

* Higher number of double strokes? Service life calculation online www.igus.eu/chainflexlife

10 million 15 million 20 million

Temperature,from/to [°C]

R min. [factor x d] R min. [factor x d] R min. [factor x d]

-35/-25 5 6 7

-25/+80 4 5 6

+80/+90 5 6 7

Double strokes*

36 month guarantee ... 1,354 types from stock ... no cutting charges

Note: The given outer diameters are maximum values and may tend toward lower tolerance limits. G = with green-yellow earth core x = without earth core

z For heaviest duty applications and especially small radii down to 4 x d z TPE outer jacket z Shielded

zOil and bio-oil resistant zPVC and halogen-free z Low-temperature-flexible zHydrolysis and microbe-resistant

20 millionDouble strokes guaranteed

4 x dBend radius, e-chain®

100 mTravel distance, e-chain®

Typical application areas z For heaviest duty applications and especially small radii down to 4 x d, Class 7 z Especially for short, very fast applications with small radii and restricted installation space, Class 5 z Almost unlimited resistance to oil, also with bio-oils, Class 4 z No torsion, Class 1 z Indoor and outdoor applications, UV-resistant z Pick and place machines, automatic doors, Clean room, very quick handling

Part No.

Number of cores and conductor nominal cross section

Outer diameter (d) max.

Copper index

Weight

[mm²] [mm] [kg/km] [kg/km]CF299.01.02 (2x0.14)C 6.0 17 36CF299.01.04 (4x0.14)C 6.5 22 45CF299.01.08 (8x0.14)C 8.5 35 75CF299.02.04 (4x0.25)C 7.0 32 57CF299.02.07 (7x0.25)C 8.5 46 83

Guarantee

month guarantee

Page 19: PVC Data cables - igus.eu...122 EU04.2019 EU04.2019 123 CF240 PVC 10 x d Data cable | PVC | chainflex® CF240 Dynamic information Bend radius e-chain® linear minimum 10 x d flexible

153152 EU04

.201

9

EU04

.201

9

CFKoaxTPE

10 x d Coax cable | TPE | chainflex® CFKoax

Dynamic informationBend radius e-chain® linear minimum 10 x d

flexible minimum 8 x dfixed minimum 5 x d

Temperature e-chain® linear -35 °C up to +100 °C (CFKoax1/3) -35 °C up to +70 °C (CFKoax2)flexible -50 °C up to +100 °C (CFKoax1/3) -50 °C up to +70 °C (CFKoax2)fixed -55 °C up to +100 °C (CFKoax1/3) -55 °C up to +70 °C (CFKoax2)

v max. unsupported 10 m/sgliding 5 m/s

a max. 100 m/s²

Travel distance Unsupported travel distances and up to 400 m and more for gliding applica-tions, Class 6

Cable structureConductor Multi-wire; adapted to single-wire diameter with pitch length to suit the require-

ments in e-chains®.Core insulation Special FEP mixture (CFKoax1/3)

Special PE mixture. (CFKoax2)Core structure Cores wound in a layer with especially short pitch length.

Core identification Coaxial elements Product range table

Element shield Extremely bending-resistant braiding made of tinned copper wires.Coverage approx. 70 % linear, approx. 90 % optical

Element jacket TPE mixture adapted to suit the requirements in e-chains®.

Outer jacket Low-adhesion, extremely abrasion-resistant and highly flexible TPE mixture, adapted to suit the requirements in e-chains®.Colour: Product range table

Exa

mpl

e im

age

PVC iguPUR PUR TPE

EPLAN download, configurators www.igus.eu/CFKoax

CFKoaxTPE

10 x d

Electrical informationNominal voltage 500/500 V (following DIN VDE 0298-3)

Testing voltage 1500 V (following DIN EN 50395)

Properties and approvalsUV resistance Medium

Oil resistance Oil resistant (following DIN EN 60811-404), bio-oil resistant (following VDMA 24568 with Plantocut 8 S-MB tested by DEA), Class 4

Silicone-free Free from silicone which can affect paint adhesion (following PV 3.10.7 – status 1992)

EAC Certificate No. RU C-DE.ME77.B.01254 (TR ZU)

Lead-free Following 2011/65/EC (RoHS-II)

Clean room According to ISO Class 1. The outer jacket material of this series complies with CF9.15.07 - tested by IPA according to standard DIN EN ISO 14644-1

CE Following 2014/35/EU

Info The coaxial elements used in cables of the CFKoax1 series are comparable with a HF75-0.3/1.6 according to MIL-C-17/94-RG179 and thus fit into an RG179 plug.The coaxial elements used in cables of the CFKoax2 series are comparable with a HF50-0.9/2.95 according to MIL-C-17/28-RG58 and thus fit into an RG58 plug.The coaxial elements used in cables of the CFKoax3 series are comparable with a HF50-0.3/0.84 according to MIL-C-17/93-RG178 and thus fit into an RG178 plug.

Class 6.6.4.1

Basic requirements low 1 2 3 4 5 6 7 highest

Travel distance unsupported 1 2 3 4 5 6 ≥ 400 m

Oil resistance none 1 2 3 4 highest

Torsion none 1 2 3 4 ±360°

36 month guarantee ... 1,354 types from stock ... no cutting charges

z For extremely heavy duty applications z TPE outer jacket zOil and bio-oil resistant zUV-resistant

zHydrolysis and microbe-resistant

10 millionDouble strokes guaranteed

10 x dBend radius, e-chain®

400 mTravel distance, e-chain®

Typical application areas z For heaviest duty applications, Class 6 z Almost unlimited resistance to oil, also with bio-oils, Class 4 z Unsupported travel distances and up to 400 m and more for gliding applications, Class 6 z No torsion, Class 1 z Indoor and outdoor applications with average sun radiation z Storage and retrieval units for high-bay warehouses, Machining units/machine tools, quick handling, Clean room, semiconductor insertion, indoor cranes, low temperature applications

Guaranteed service life (details see page 22-23)

* Higher number of double strokes? Online lifetime calculation: www.igus.eu/chainflexlife

*

Double strokes* 5 million 7.5 million 10 million

Temperature,from/to [°C]

R min. [factor x d]

R min. [factor x d]

R min. [factor x d]

-35/-25 12,5 13,5 14,5

-25/+60 (CFKoax2) 10 11 12

-25/+90 (CFKoax1/3) 10 11 12

+60/+70 (CFKoax2) 12,5 13,5 14,5

+90/+100 (CFKoax1/3) 12,5 13,5 14,5

Guarantee

month guarantee

Page 20: PVC Data cables - igus.eu...122 EU04.2019 EU04.2019 123 CF240 PVC 10 x d Data cable | PVC | chainflex® CF240 Dynamic information Bend radius e-chain® linear minimum 10 x d flexible

155154 EU04

.201

9

EU04

.201

9

Example image

Coax cable | TPE | chainflex® CFKoax

Part No. Coaxial elements Outer diameter (d) max.

Copper index

Weight

[mm] [kg/km] [kg/km]CFKoax1.01 1 4.5 7 23CFKoax1.05 5 10.0 33 110CFKoax2.01 1 5.5 19 36CFKoax3.01 1 3.0 5 11

Part No. Characteristic wace imped-ance [Ω]]

Conductor/ Core diameter nominal [mm]

Colour code Colour outer jacket (similar to RAL)

CFKoax1.01 75 0.3/1.6 red Steel-blue (similar to RAL 5011)CFKoax1.05 75 0.3/1.6 red, green, blue, white, black Steel-blue (similar to RAL 5011)CFKoax2.01 50 0.9/2.95 - Jet black (similar to RAL 9005)CFKoax3.01 50 0.3/0.85 - Window-grey (similar to RAL 7040)

Note: The given outer diameters are maximum values and may tend toward lower tolerance limits. G = with green-yellow earth core x = without earth core

CFKoaxTPE

10 x d

PVC iguPUR PUR TPE

EPLAN download, configurators www.igus.eu/CFKoax

CFKoaxTPE

10 x d

Order example: CFKoax1.01 – to your desired length (0.5 m steps)CFKoax chainflex® series .01 Number of coaxial elements

Online order www.chainflex.eu/CFKoax

Delivery time 24hrs or today.Delivery time means time until goods are shipped.

Class 6.6.4.1

Basic requirements low 1 2 3 4 5 6 7 highest

Travel distance unsupported 1 2 3 4 5 6 ≥ 400 m

Oil resistance none 1 2 3 4 highest

Torsion none 1 2 3 4 ±360°

36 month guarantee ... 1,354 types from stock ... no cutting charges

Coax cable and other chainflex® cables in stage technology. e-chain®: System E4/4

Guarantee

month guarantee