ps/spd power supplies
DESCRIPTION
PS/SPD Power Supplies. 19 May 2014. Pascal Perret LPC Clermont. ECAL Platform: Maraton. PS/SPD FE power supplies: 0M05.0002M (+ OPFC.0001): 8+2 - PowerPoint PPT PresentationTRANSCRIPT
PS/SPD Power Supplies
Pascal Perret
LPC Clermont
19 May 2014
2
ECAL Platform: Maraton
PS/SPD FE power supplies: 0M05.0002M (+ OPFC.0001): 8+2
• 12 Channel Maraton - (+5v/100A, 3v3/100A, -5v/50A, +5v/50A) - LHCb Calorimeter. Std type plastic input connector. For use in radiation tolerant crate applications:• 3 modules (6 channels)
Pascal Perret - LPC Clermont19/05/2014
Could be re-used by ECAL/HCAL
46u
free space (1u)
Deflector (2u)
Heat Exchanger (1u)
ECAL 13(9u)
Heat Exchanger (1u)
ECAL 14(9u)
Turbine (4u)
ECAL platform<- cryogenics beampipe ->
free space (1u)
Power Supply incl.
Power Supply incl.
Heat Exchanger (1u)
PRS 3(9u)
free space (1u)
Power Supply incl.
Connection coolingsystem (3u)
free space (4u)
46u
free space (1u)
Deflector (2u)
Heat Exchanger (1u)
ECAL 11(9u)
Heat Exchanger (1u)
ECAL 12(9u)
Turbine (4u)
free space (1u)
Power Supply incl.
Power Supply incl.
Heat Exchanger (1u)
PRS 2(9u)
free space (1u)
Power Supply incl.
Connection coolingsystem (3u)
free space (4u)
46u
free space (1u)
Deflector (2u)
Heat Exchanger (1u)
ECAL 8(9u)
Heat Exchanger (1u)
ECAL 9(9u)
Turbine (4u)
free space (1u)
Power Supply incl.
Power Supply incl.
Heat Exchanger (1u)
PRS 0(9u)
free space (1u)
Power Supply incl.
Connection coolingsystem (3u)
free space (4u)
Rack L3B01 Rack L3B02 Rack L3B04
46u
free space (1u)
Deflector (2u)
Heat Exchanger (1u)
ECAL 10(9u)
Heat Exchanger (1u)
Turbine (4u)
free space (1u)
Power Supply incl.
Heat Exchanger (1u)
PRS 1(9u)
free space (1u)
Power Supply incl.
free space (4u)
Rack L3B03
VFE Supply + conn.cooling (3u)
CW converters + PS/SPD LED
(6u)
PS temperature (3u)
Version 17/01/06
3
ECAL Platform: Maraton
PS/SPD VFE power supplies: 0M22.0003 (+ OPFC.0001): 2+2
• 12 Channel Maraton - 3U 19" power box, 385VDC input, 12 channel DC output, 2-8V, 300W nominal, 55A max, 50A continuous, analogue controlled interface. Water cooled, no magnetic screening.• 6 modules (12 channels)
Pascal Perret - LPC Clermont19/05/2014
Could be re-used by SciFi
46u
free space (1u)
Deflector (2u)
Heat Exchanger (1u)
ECAL 13(9u)
Heat Exchanger (1u)
ECAL 14(9u)
Turbine (4u)
ECAL platform<- cryogenics beampipe ->
free space (1u)
Power Supply incl.
Power Supply incl.
Heat Exchanger (1u)
PRS 3(9u)
free space (1u)
Power Supply incl.
Connection coolingsystem (3u)
free space (4u)
46u
free space (1u)
Deflector (2u)
Heat Exchanger (1u)
ECAL 11(9u)
Heat Exchanger (1u)
ECAL 12(9u)
Turbine (4u)
free space (1u)
Power Supply incl.
Power Supply incl.
Heat Exchanger (1u)
PRS 2(9u)
free space (1u)
Power Supply incl.
Connection coolingsystem (3u)
free space (4u)
46u
free space (1u)
Deflector (2u)
Heat Exchanger (1u)
ECAL 8(9u)
Heat Exchanger (1u)
ECAL 9(9u)
Turbine (4u)
free space (1u)
Power Supply incl.
Power Supply incl.
Heat Exchanger (1u)
PRS 0(9u)
free space (1u)
Power Supply incl.
Connection coolingsystem (3u)
free space (4u)
Rack L3B01 Rack L3B02 Rack L3B04
46u
free space (1u)
Deflector (2u)
Heat Exchanger (1u)
ECAL 10(9u)
Heat Exchanger (1u)
Turbine (4u)
free space (1u)
Power Supply incl.
Heat Exchanger (1u)
PRS 1(9u)
free space (1u)
Power Supply incl.
free space (4u)
Rack L3B03
VFE Supply + conn.cooling (3u)
CW converters + PS/SPD LED
(6u)
PS temperature (3u)
Version 17/01/06