protect - workwear group online · 4 6.8 cal 8.4 cal 70e nfpa 2112 nfpa iso 11612 guide to our...
TRANSCRIPT
Hard Yakka’s reputation is built on hard work. We pride ourselves on having produced quality workwear for over 80 years, and with good reason. Our products are specifically engineered to endure the toughest of conditions while delivering comfort, safety and durability at all times.
PROTECT is our most tenacious range of workwear yet. It’s rugged, comfortable and practical – and delivers protection against flash fire and arc flash. Like all Hard Yakka products, the PROTECT range delivers
superior comfort and design innovation without compromising your safety.
The ShieldTEC flame resistant ("FR") range meets the toughest Australian and New Zealand guidelines for flame resistant garments and safety standards worldwide.
ShieldTEC FR garments are independently tested and certified to:
• NFPA 2112 Protection of Industrial Personnel Against Flash Fire
• ISO 11612 Clothing to Protect Against Heat and Flame
And tested to NFPA 70E Electrical Safety in the Workplace. The garments also meet ENA
NENS09 National Guidelines for Electrical Arc Hazards.
Importantly for Australian conditions, Hard Yakka ShieldTEC FR offers superior protection, breathability and comfort, helping to reduce the risks of heat stress.
All ShieldTEC FR garments provide UPF 50+, Excellent Protection rating while remaining durable, lightweight and moisture wicking.
Whatever your industry, ShieldTEC FR workwear buys you vital seconds that could save your life.
PROTECT
CONTENTS Guide to Our Icons 4
State of the Nation: FR Safety Report 5
ShieldTec FR Uppers 7
ShieldTec FR Lowers 11
Quick Reference Guide 14
Product Overview 15
FR Protection: Industry Information 16
Product Testing & Industry Standards 17
Important Terminology 18
Fitting Guide 19
4
6.8
CAL
8.4
CAL
70E
NFPA
2112
NFPA
ISO 11612
GUIDE TO OUR ICONS
UPF RATINGAn Ultraviolet Protection Factor (UPF) rating for Ultraviolet Radiation transmitted through a fabric onto the skin. Look for garments with a UPF 40 or 50+ rating to be assured of excellent protection.
HI-VISIBILITY DAY/NIGHTFor use in day, night, dawn, dusk or in poor weather conditions where there is illumination from headlights. Complies with AS/NZS 4602.1:2011 High-Visibility Safety Garments Class Day/Night.
MOISTURE MANAGEMENTFabric is engineered to wick moisture away from the skin and to the fabric surface so that you stay dry, cool and safe.
LIGHTWEIGHT FABRICFabric is lightweight to keep you cool and comfortable.
HI-VISIBILITY DAYA garment that uses high-visibility materials for outdoor use only. Complies with AS/NZS 4602.1:2011 High-Visibility Safety Garments Class Day.
CAL 8.4Protective value rating of ATPV 8.4 cal/cm2 which meets NFPA 70E:2015, Category 2.
NFPA 2112:2012Certified to the USA's NFPA 2112:2012 Flame-Resistant Garments for Protection of Industrial Personnel Against Flash Fire.
NFPA 70E:2015Tested to the USA's NFPA 70E:2015 Electrical Safety in the Workplace Standard.
ANTI-STATICDesigned to reduce the build up of excess static electricity. This offers a level of protection against ignition hazards such as flammable materials and gases.
ISO 11612:2015Certified to Europe's ISO 11612:2015 Protective Clothing – Clothing to Protect Against Heat and Flame Standard.
CAL 6.8Protective value rating of ATPV 6.8 cal/cm2 which meets NFPA 70E:2015, Category 1.
5
There are over 2.85 million people working in industries exposed to arc flash and flash fire across Australia. Through the Hard Yakka flame resistant (FR) clothing safety report, we aimed to uncover the level to which employees protect themselves at work and sought to understand the number of injuries that take place onsite as a result of insufficient protection. The report is alarming, and key insights can be found below.
Based on research of 500 people working in fields at risk of arc flash and flash fire. Research conducted by Symphony Research on behalf of Hard Yakka PROTECT in June 2015.
MOST AT RISK
Electrical & Energy workers are at the biggest risk to arc flash (74%).
Emergency Services workers are at the biggest risk to flash fire (59%).
INJURIES
RECOVERY
INJURED AREA
56%56% of workers have experienced a near miss injury due to arc flash or flash fire.
21% 16% 23%Third degree burns (21%) Second degree burns (16%) First degree burns (23%)
47% 10% 83%47% of those injured took
longer than a week o� work10% spent more than
$15,000 on medical care83% of participants had
immediate access to first aid when injured
$
3% Eyes 20% Face
17% Shoulders
14% Back
35% Hands
9% Feet
16% Neck
34% Arms
13% Chest
23% Legs
37%
MISTAKEN WORKPLACE FR FIBRES
28%28% DO NOT wear FR clothing, with the main reason being that their company doesn’t supply it to them (36%), and they don’t feel they need to (31%).
There is some confusion over what constitutes an FR fibre: Only 37% were able to correctly identify FR fibres. Cotton (25%) was the most commonly mistaken fibre for FR.
67% of those who wear FR clothing could not correctly name FR fibres.
67%
74%
59%
STATE OF THE NATION: FR SAFETY REPORT
7
SHIELD
TEC FR
SHIELDTEC FR UPPERSLightweight fire resistant range of shirts to reduce risk from Arc and Flash fire events.
• Lightweight 195gsm (Protex®) Modacrylic, Pima Cotton, (Kevlar®) Para-Aramid, Nylon and (Beltron®) Anti-static fibre
• Anti-static fibre, intimately blended
• Rip-stop fabric increases durability
• Two chest pockets with reinforcement
• Pleated yoke, side body and gusset plus articulated sleeves for movement
• Gusset cuff for protection
• Heat resistant trims tested to 260°C
• FR reflective tape – hoop configuration*
• Size range: S – 5XL
Articulated sleeves for movement
NFPA 2112 certified trims test to 260°C
Pleated yoke for movement
Side body and gusset for comfort and movement
Gusset cuff for protection
Twin needled for strength. All thread NFPA 2112 certified.
Open and closed front options with concealed placket
* Y04050, Y04150, Y04350, Y04550ATPV: 6.8 CAL/CM2
8
Y04350 HI-VIS SPLICED OPEN FRONT LONG SLEEVE SHIRT WITH FR TAPE
Yellow/Navy (YNA) Orange/Navy (ONA)Navy (NAV)
Y04150 FULL HI-VIS CLOSED FRONT LONG SLEEVE SHIRT WITH FR TAPE
Safety Orange (SOR)
Y04250 LONG SLEEVE CLOSED FRONT SHIRT
6.8
CAL
6.8
CAL
6.8
CAL
70E
NFPA
70E
NFPA
70E
NFPA
2112
NFPA
2112
NFPA
2112
NFPA
ISO 11612 ISO 11612 ISO 11612
SHIELDTEC FR
9
Y04550 HI-VIS SPLICED CLOSED FRONT LONG SLEEVE SHIRT WITH FR TAPE
Yellow/Navy (YNA) Orange/Navy (ONA)
Y04450 HI-VIS SPLICED OPEN FRONT LONG SLEEVE SHIRT
Yellow/Navy (YNA) Orange/Navy (ONA)
Y04050 WOMEN'S HI-VIS SPLICED OPEN FRONT LONG SLEEVE SHIRT WITH FR TAPE
Yellow/Navy (YNA) Orange/Navy (ONA)
6.8
CAL
6.8
CAL
6.8
CAL
70E
NFPA
70E
NFPA
70E
NFPA
2112
NFPA
2112
NFPA
2112
NFPA
ISO 11612 ISO 11612 ISO 11612
SHIELD
TEC FR
11
SHIELD
TEC FR
SHIELDTEC FR LOWERSFire resistant range of pants to reduce risk from Arc and Flash fire events.
• 235gsm (Protex®) Modacrylic, Pima Cotton, (Kevlar®) Para-Aramid, Nylon and (Beltron®) Anti-static fibre
• Anti-static fibre, intimately blended
• Inleg gusset for comfort and movement
• Articulated knees
• Secure pockets for storage on cargo styles
• FR reflective tape - hoop configuration*
• Size range: Men's 77R – 107R, 87S – 112S Women's 8 – 22
* Y02320, Y02425, Y02525 ATPV: 8.4 CAL/CM2
Articulated knees for movement
NFPA 2112 certified trims test to 260°C
Inleg gusset for comfort and movement
Twin needled and bar tacked for strength. All thread NFPA 2112 certified.
Plain front pant, cargo pant, women's options with and without tape
12
Y02525 FLAT FRONT CARGO POCKET PANT WITH FR TAPE
Navy (NAV)
Y02520 FLAT FRONT CARGO POCKET PANT
Navy (NAV)
Y02425 FLAT FRONT PANT (NO POCKETS) WITH FR TAPE
Navy (NAV)
8.4
CAL
8.4
CAL
8.4
CAL
70E
NFPA
70E
NFPA
70E
NFPA
2112
NFPA
2112
NFPA
2112
NFPA
ISO 11612 ISO 11612 ISO 11612
SHIELDTEC FR
13
Y02320 WOMEN'S CARGO PANT WITH TAPE
Navy (NAV) Navy (NAV)
Y02325 WOMEN'S FLAT FRONT PANT WITH TAPE (NO POCKETS)
Navy (NAV)
Y02420 FLAT FRONT PANT (NO POCKETS)
8.4
CAL
8.4
CAL
8.4
CAL
70E
NFPA
70E
NFPA
70E
NFPA
2112
NFPA
2112
NFPA
2112
NFPA
ISO 11612 ISO 11612 ISO 11612
SHIELD
TEC FR
Range Comparison SHIELDTEC FR
Bulwark iQ Series TECGEN™ Tecasafe Plus Tecasafe Plus
(Y00308 only)
Fabric exclusive to Hard Yakka PROTECT in Australasia
Heat stress management rating (3=best, 2=better, 1=good) 2-3 3 2-3 2 2-3
Weight & CAL rating – upper body garments (includes shirts, polos, coveralls)
195gsm, 6.8 cal/cm2
180gsm, 8.2 cal/cm2
217gsm, 8.6 cal/cm2
238gsm, 8.9 cal/cm2
197gsm, 5.7 cal/cm2
Weight & CAL – lower body garments (includes pants)
235gsm, 8.4 cal/cm2
425gsm, 13 cal/cm2
214gsm, 8.6 cal/cm2
238gsm, 8.9 cal/cm2 NA
Garments AND fabric certified to NFPA 2112
Garments AND fabric certified to ISO 11612
NFPA 2112 certified trims tested to 260°C
Fabric tested to NFPA 70E & NFPA 2112
Fabric meets ENA NENS 09 Guidelines for Electric Arc Hazards
AS/NZS 4399:1996 UPF Rating50+ Excellent
Protection30+ Very Good
Protection50+ Excellent
Protection50+ Excellent
Protection50+ Excellent
Protection
Meets NS/NZS 4602.1:2011 for high-visibility safety garments
Tape Options FR Tape Segmented FR Tape
Perforated FR Tape FR Tape FR Tape
Use of FR trims such as fasteners, thread and reflective tape
FR properties do not wash out
PROTECT QUICK REFERENCE GUIDE
14
Style Description NFPA 2112
NFPA 70E ISO 11612
NENS COMPLI-
ANTAS 4602
DAYAS 4602
DAY/NIGHT
ATPV 6.8 CAL/
CM2
ATPV 8.4 CAL/
CM2
195 GSM FABRIC
235 GSM FABRIC FR TAPE
TRIMS TESTED
TO 260°C
UPF 50+ CLOSED FRONT
OPEN FRONT
GUSSET CUFF
ARTICU- LATED
FIT
Y04150 Full Hi-Vis Closed Front Long Sleeve Shirt with FR tape
Y04250 Long Sleeve Closed Front Shirt
Y04350 Hi-Vis Spliced Open Front Long Sleeve Shirt with FR tape
Y04450 Hi-Vis Spliced Open Front Long Sleeve Shirt
Y04550 Hi-Vis Spliced Closed Front Long Sleeve Shirt with FR tape
Y02420 Flat front pant (no pockets)
Y02425 Flat front pant (no pockets) with FR tape
Y02520 Flat front cargo pocket pant
Y02525 Flat front cargo pocket pant with FR tape
Y04050 Women's Hi-Vis Spliced Open Front Long Sleeve Shirt with FR tape
Y02320 Women's Cargo Pant with FR tape
Y02325 Women's Flat front pant with FR tape (no pockets)
15
SHIELDTEC FR PRODUCT OVERVIEW
16
Every day workers expose themselves to potentially hazardous environments that cause flash fires and arc flash, leading to common injuries such as burns, respiratory system damage, hearing damage and even fatalities.
The demand for flame resistant clothing is growing rapidly as industries build an understanding of the hazardous nature of their working environments and their apparel protection requirements. The use of flame resistant clothing provides the necessary protection to reduce the risk of serious, or even fatal injuries.
Hard Yakka PROTECT workwear is specifically designed to cater for the increasing demands of multiple industries including electrical, energy, oil, gas and mining.
Electrical & EnergyIn the electrical and energy industries the most common risk is an arc flash event. Arc flash events typically occur around energised equipment such as power boards, power lines and general powered equipment. Arc flash events can cause serious and even fatal injuries.
Flame resistant workwear in these industries is intended to self-extinguish flame that has ignited on the garment and provide protection against second-degree burns. Heat stress management is also important for safety.
Oil & GasOil and gas industry workers can be exposed to flash fires, arc flash events (if operating energised equipment) and extreme heat conditions. Wearing flame resistant clothing that self-extinguishes can give workers much needed time to escape a flash fire and dramatically reduce burn injuries.
Heat stress management is also critical, with most upstream oil and gas activities concentrated in hot climates. Flame resistant clothing aims to provide both FR protection and breathability through fabric technology and garment design.
MiningMiners can be exposed to both flash fires and arc flash events. Typical mine site workers at risk include boilermakers, drillers and electricians. Flame resistant workwear can protect workers against second and third degree burns and manage heat stress in hot/humid conditions.
FR PROTECTION: INDUSTRY INFORMATION
17
Flame resistant garments are driven by standards and specifications that must pass intensive testing before they can be offered in any marketplace.
A basic understanding of how flame resistance is defined and measured is very important. The following is a list of the industry standards to which ShieldTEC FR garments are compliant and certified.
NFPA 70E – National Fire Protection Association, National Electrical CodeThe USA's NFPA 70E guidelines require employees working on or near energised parts and equipment to wear situationally appropriate FR clothing that meets the requirements of test method ASTM F1506. ASTM F1506 provides the minimum performance specifications for protective clothing and outlines the required testing methods to measure the Arc Thermal Protection Value (ATPV).
ENA NENS 09 – National Guidelines for the Selection, Use & Maintenance of Personal Protective Equipment for Electrical Hazards Energy Networks Association is an Australian body who administers NENS 09 guidelines which set the minimum standards for the selection, use and maintenance of personal protective equipment (PPE) when used to protect employees against electrical hazards within the electricity supply industry.
NFPA 2112 – National Fire Protection Association Standard on Flame Resistant Garments for Protection of Industrial Personnel Against Flash FireOriginating in the USA, NFPA 2112 is an industry guide to flame resistant garments for protection of industrial personnel against flash fire. The standard provides minimum performance criteria and outlines 17 test methods including: flame resistance, char-length, thermal shrinkage resistance and heat resistance.
ISO 11612:2015 Protective Clothing – Clothing to Protect Against Heat and FlameISO is an independent European based organization that develops international standards for participating member countries. ISO standard 11612:2015 provides the wearer with protection against transitory contact with heat and flame. The heat can be convection heat, thermal radiation, metal splash or a combination of these.
Garments are given the following classifications based on specific parameters:
(A1) Limited flame spread, surface ignition method(A2) Limited flame spread, edge ignition method(B) Convection heat(C) Thermal radiation(D) Molten aluminum splash (E) Molten iron splash(F) Contact heat
AS/NZS 4602.1:2011 Australian and New Zealand High-Visibility StandardsStandards for high-visibility clothing dictate workwear colour and design to ensure workers are seen in high risk situations. All Hard Yakka PROTECT Hi-Visibility Workwear complies with AS/NZS 4602.1:2011 for high-visibility safety garments.
AS/NZS 4399:1996 Sun Protective ClothingAll ShieldTEC FR garments are rated UPF 50+ Excellent Protection.
WARNING: ShieldTEC garments are not intended for fire entry, structural or wildlands fire fighting activities and provide no personal protection from chemical exposure.
They should be removed at once if contaminated with flammable liquid or material.
Both upper and lower body must be covered by a combination of FR shirt and FR pants, worn with the shirt tucked into the pants. All fasteners must be closed at all times during use. Sleeves and pants are not to be worn rolled up.
PRODUCT TESTING & INDUSTRY STANDARDS
1818
Arc FlashA type of electrical explosion. An arc flash is not an electric shock – it occurs when uncontrolled amounts of electric current travel through air between two conductors.
Arc Thermal Performance Value (ATPV) This value is presented in calories per square centimetre (cal/cm2) and represents the maximum capability for arc flash protection of a particular garment. The incident energy on a fabric or material that results in a 50% probability that sufficient heat transfer through the tested specimen is predicted to cause the onset of a second degree skin burn injury.
Cotton Drill WorkwearClothing designed to do everyday work. There is a misconception that untreated 100% cotton fabric is somehow “flame resistant”. This is simply not true. While heavyweight, untreated 100% cotton fabrics may be more difficult to ignite they can, and will, ignite and continue to burn if exposed to an ignition source.
Fire Retardant WorkwearStructural garments targeted to firefighting industries that are intended to prevent ignition.
Flame Resistant WorkwearFlame resistant fabrics and garments are intended to resist ignition, prevent the spread of flames and to self-extinguish almost immediately upon removal of the ignition source. Flame resistant workwear is abbreviated in this catalogue as 'FR'.
Flash FireA rapidly moving flame front which can be a combustion explosion.
Inherent FR FabricInherently flame resistant fibres are defined as having flame resistance as an essential characteristic of the fibre. It is a fabric that does not support combustion and has innate flame resistant properties that are permanent and inseparable; the flame resistant qualities will never wash out.
Treated FR FabricFibres that are not normally considered flame resistant which have been chemically treated to provide FR protection.
IMPORTANT TERMINOLOGY
19
FITTING GUIDEMEN'S REGULAR PANT
SIZE TABLE
BODY MEASUREMENT
GARMENT MEASUREMENT
AWAIST
(CM)
BHEIGHT
(CM)WAIST
(CM)INSEAM
(CM)
77R 77 178-188 78 83
82R 82 178-188 83 83
87R 87 178-188 88 83
92R 92 178-188 93 83
97R 97 178-188 98 83
102R 102 178-188 103 83
107R 107 178-188 108 83
MEN'S STOUT PANT
SIZE TABLE
BODY MEASUREMENT
GARMENT MEASUREMENT
AWAIST
(CM)
BHEIGHT
(CM)WAIST
(CM)INSEAM
(CM)
87S 87 163-173 88 78
92S 92 163-173 93 78
97S 97 163-173 98 78
102S 102 163-173 103 78
107S 107 163-173 108 78
112S 112 163-173 113 78
117S 117 163-173 118 78
122S 122 163-173 123 78
127S 127 163-173 128 78
132S 132 163-173 133 78
MEN'S SHIRT
SIZE TABLE
BODY MEASUREMENT
GARMENT MEASUREMENT
AWAIST
(CM)
BHEIGHT
(CM)WAIST (CM)
S 92 178-188 113
M 97 178-188 118
L 102 178-188 123
XL 110 178-188 131
2XL 118 178-188 139
3XL 126 178-188 147
4XL 134 178-188 155
5XL 142 178-188 163
DATE CREATED: 9/10/2015
DIMENSIONS: 100x158 mm PMS Process Black
MARK UP (do not print)White
WARNINGTHIS GARMENT IS NOT INTENDED FOR FIRE ENTRY, STRUCTURAL
OR WILDLANDS FIRE FIGHTING ACTIVITIES AND PROVIDES NO PERSONAL PROTECTION FROM CHEMICAL EXPOSURE.
REMOVE AT ONCE IF CONTAMINATED WITH FLAMMABLE LIQUID OR MATERIAL.
BOTH UPPER AND LOWER BODY MUST BE COVERED BY A COMBINATION OF FIRE RESISTANT (FR) SHIRT AND FR PANTS,
WORN WITH THE SHIRT TUCKED INTO THE PANTS. REACH ARMS UPWARD TO ENSURE NO PART OF THE TORSO IS EXPOSED
DURING ANY MOVEMENT. ALL FASTENERS MUST BE CLOSED AT ALL TIMES DURING USE. SLEEVES AND PANTS ARE
NOT TO BE WORN ROLLED-UP.USE FLAME RESISTANT THREAD FOR EMBROIDERY. ANY ALTERATIONS MAY IMPACT THE COMPLIANCE,
PERFORMANCE AND FUNCTIONALITY OF THE GARMENT.
THIS GARMENT IS FLAME RESISTANTTHIS GARMENT MEETS THE PERFORMANCE REQUIREMENTS OF
NFPA 70E-2015: ASTM 1506-10A AND IS CERTIFIED TO ISO 11612:2015.
ML-1126-HY - SHIELDTEC FR WOVEN MENS REGULAR PANT
DO NOT REMOVE THIS LABEL
B
A
SIZETABLE
77R
82R
87R
92R
97R
102R
107R
AWAIST(CM)
77
82
87
92
97
102
107
ML-
1126
-HY
BHEIGHT
(CM)178-188
178-188
178-188
178-188
178-188
178-188
178-188
WAIST(CM)
78
83
88
93
98
103
108
INSEAM(CM)
83
83
83
83
83
83
83
GARMENTMEASUREMENT
BODY MEASUREMENT
ISO 11612:2015
A1 A2 B1 C1 F1
READ USER
INSTRUCTIONSBMP 642936
DATE CREATED: 9/10/2015
DIMENSIONS: 100x154 mm PMS Process Black
MARK UP (do not print)White
WARNINGTHIS GARMENT IS NOT INTENDED FOR FIRE ENTRY, STRUCTURAL
OR WILDLANDS FIRE FIGHTING ACTIVITIES AND PROVIDES NO PERSONAL PROTECTION FROM CHEMICAL EXPOSURE.
REMOVE AT ONCE IF CONTAMINATED WITH FLAMMABLE LIQUID OR MATERIAL.
BOTH UPPER AND LOWER BODY MUST BE COVERED BY A COMBINATION OF FIRE RESISTANT (FR) SHIRT AND FR PANTS,
WORN WITH THE SHIRT TUCKED INTO THE PANTS. REACH ARMS UPWARD TO ENSURE NO PART OF THE TORSO IS EXPOSED
DURING ANY MOVEMENT. ALL FASTENERS MUST BE CLOSED AT ALL TIMES DURING USE. SLEEVES AND PANTS ARE
NOT TO BE WORN ROLLED-UP.USE FLAME RESISTANT THREAD FOR EMBROIDERY. ANY ALTERATIONS MAY IMPACT THE COMPLIANCE,
PERFORMANCE AND FUNCTIONALITY OF THE GARMENT.
THIS GARMENT IS FLAME RESISTANTTHIS GARMENT MEETS THE PERFORMANCE REQUIREMENTS OF
NFPA 70E-2015: ASTM 1506-10A AND IS CERTIFIED TO ISO 11612:2015.
ML-1127-HY - SHIELDTEC FR WOVEN MENS STOUT PANT
B
A
DO NOT REMOVE THIS LABEL
SIZE TABLE
87S
92S
97S
102S
107S
112S
AWAIST(CM)
87
92
97
102
107
112
ML-
1127
-HY
BHEIGHT
(CM)163-173
163-173
163-173
163-173
163-173
163-173
WAIST(CM)
88
93
98
103
108
113
INSEAM(CM)
78
78
78
78
78
78
BODY MEASUREMENT GARMENTMEASUREMENT
ISO 11612:2015
A1 A2 B1 C1 F1
READ USER
INSTRUCTIONSBMP 642936
DATE CREATED: 9/10//2015
DIMENSIONS: 100x157 mm PMS Process Black
MARK UP (do not print)White
WARNINGTHIS GARMENT IS NOT INTENDED FOR FIRE ENTRY, STRUCTURAL
OR WILDLANDS FIRE FIGHTING ACTIVITIES AND PROVIDES NO PERSONAL PROTECTION FROM CHEMICAL EXPOSURE.
REMOVE AT ONCE IF CONTAMINATED WITH FLAMMABLE LIQUID OR MATERIAL.
BOTH UPPER AND LOWER BODY MUST BE COVERED BY A COMBINATION OF FIRE RESISTANT (FR) SHIRT AND FR PANTS,
WORN WITH THE SHIRT TUCKED INTO THE PANTS. REACH ARMS UPWARD TO ENSURE NO PART OF THE TORSO IS EXPOSED
DURING ANY MOVEMENT. ALL FASTENERS MUST BE CLOSED AT ALL TIMES DURING USE. SLEEVES AND PANTS ARE
NOT TO BE WORN ROLLED-UP.USE FLAME RESISTANT THREAD FOR EMBROIDERY. ANY ALTERATIONS MAY IMPACT THE COMPLIANCE,
PERFORMANCE AND FUNCTIONALITY OF THE GARMENT.
THIS GARMENT IS FLAME RESISTANTTHIS GARMENT MEETS THE PERFORMANCE REQUIREMENTS OF
NFPA 70E-2015: ASTM 1506-10A AND IS CERTIFIED TO ISO 11612:2015.
ML-1129-HY - SHIELDTEC FR WOVEN MENS SHIRT
DO NOT REMOVE THIS LABEL
A
B
SIZE TABLE
SML
XL2XL3XL4XL5XL
ACHEST(CM)
9297102110118126134142
ML-
1129
-HY
BHEIGHT
(CM)178-188178-188178-188178-188178-188178-188178-188178-188
CHEST(CM)113118123131139147155163
BODY MEASUREMENT GARMENTMEASUREMENT
ISO 11612:2015
A1 A2 B1 C1
READ USER
INSTRUCTIONSBMP 642936
WOMEN'S SHIRT
SIZE TABLE
BODY MEASUREMENT
GARMENT MEASUREMENT
A CHEST
(CM)
BWAIST
(CM)
CHEIGHT
(CM)CHEST (CM)
6 80 62 168-173 93
8 85 67 168-173 98
10 90 72 168-173 103
12 95 77 168-173 108
14 100 82 168-173 113
16 105 87 168-173 118
18 110 92 168-173 125
20 115 97 168-173 133
22 120 102 168-173 139
24 125 107 168-173 145
WOMEN'S PANT
SIZE TABLE
BODY MEASUREMENT
GARMENT MEASUREMENT
A WAIST
(CM)
BHIP
(CM)
CHEIGHT
(CM)HIP
(CM)INSEAM
(CM)
6 62 88 168-173 94 81
8 67 93 168-173 100 81
10 72 98 168-173 105 81
12 77 103 168-173 110 81
14 82 108 168-173 115 81
16 87 113 168-173 120 81
18 92 118 168-173 128 81
20 97 123 168-173 135 81
22 102 128 168-173 140 81
24 107 133 168-173 145 81
DATE CREATED: 9/10/2015
DIMENSIONS: 100x159 mm PMS Process Black
MARK UP (do not print)White
WARNINGTHIS GARMENT IS NOT INTENDED FOR FIRE ENTRY, STRUCTURAL
OR WILDLANDS FIRE FIGHTING ACTIVITIES AND PROVIDES NO PERSONAL PROTECTION FROM CHEMICAL EXPOSURE.
REMOVE AT ONCE IF CONTAMINATED WITH FLAMMABLE LIQUID OR MATERIAL.
BOTH UPPER AND LOWER BODY MUST BE COVERED BY A COMBINATION OF FIRE RESISTANT (FR) SHIRT AND FR PANTS,
WORN WITH THE SHIRT TUCKED INTO THE PANTS. REACH ARMS UPWARD TO ENSURE NO PART OF THE TORSO IS EXPOSED
DURING ANY MOVEMENT. ALL FASTENERS MUST BE CLOSED AT ALL TIMES DURING USE. SLEEVES AND PANTS ARE
NOT TO BE WORN ROLLED-UP.USE FLAME RESISTANT THREAD FOR EMBROIDERY. ANY ALTERATIONS MAY IMPACT THE COMPLIANCE,
PERFORMANCE AND FUNCTIONALITY OF THE GARMENT.
THIS GARMENT IS FLAME RESISTANTTHIS GARMENT MEETS THE PERFORMANCE REQUIREMENTS OF
NFPA 70E-2015: ASTM 1506-10A AND IS CERTIFIED TO ISO 11612:2015.
ML-1128-HY - SHIELDTEC FR WOVEN WOMENS PANT
B
C
A
DO NOT REMOVE THIS LABEL
SIZE TABLE
681012141618202224
AWAIST(CM)
6267727782879297102107
BHIP
(CM)889398103108113118123128133
ML-
1128
-HY
CHEIGHT
(CM)168-173168-173168-173168-173168-173168-173168-173168-173168-173168-173
HIP(CM)94100105110115120128135140145
INSEAM(CM)
81818181818181818181
BODY MEASUREMENT GARMENTMEASUREMENT
ISO 11612:2015
A1 A2 B1 C1 F1
READ USER
INSTRUCTIONSBMP 642936
DATE CREATED: 9/10/2015
DIMENSIONS: 100x159 mm PMS Process Black
MARK UP (do not print)White
WARNINGTHIS GARMENT IS NOT INTENDED FOR FIRE ENTRY, STRUCTURAL
OR WILDLANDS FIRE FIGHTING ACTIVITIES AND PROVIDES NO PERSONAL PROTECTION FROM CHEMICAL EXPOSURE.
REMOVE AT ONCE IF CONTAMINATED WITH FLAMMABLE LIQUID OR MATERIAL.
BOTH UPPER AND LOWER BODY MUST BE COVERED BY A COMBINATION OF FIRE RESISTANT (FR) SHIRT AND FR PANTS,
WORN WITH THE SHIRT TUCKED INTO THE PANTS. REACH ARMS UPWARD TO ENSURE NO PART OF THE TORSO IS EXPOSED
DURING ANY MOVEMENT. ALL FASTENERS MUST BE CLOSED AT ALL TIMES DURING USE. SLEEVES AND PANTS ARE
NOT TO BE WORN ROLLED-UP.USE FLAME RESISTANT THREAD FOR EMBROIDERY. ANY ALTERATIONS MAY IMPACT THE COMPLIANCE,
PERFORMANCE AND FUNCTIONALITY OF THE GARMENT.
THIS GARMENT IS FLAME RESISTANTTHIS GARMENT MEETS THE PERFORMANCE REQUIREMENTS OF
NFPA 70E-2015: ASTM 1506-10A AND IS CERTIFIED TO ISO 11612:2015.
ML-1130-HY - SHIELDTEC FR WOVEN WOMENS SHIRT
A
C
B
DO NOT REMOVE THIS LABEL
SIZE TABLE
681012141618202224
ACHEST(CM)80859095100105110115120125
BWAIST(CM)
6267727782879297102107
ML-
1130
-HY
CHEIGHT
(CM)168-173168-173168-173168-173168-173168-173168-173168-173168-173168-173
CHEST(CM)
9398103108113118125133139145
BODY MEASUREMENT GARMENTMEASUREMENT
ISO 11612:2015
A1 A2 B1 C1
READ USER
INSTRUCTIONSBMP 642936