Page 1: Programming the CD101. Push and hold the SET button for 3 seconds

Programming the CD101

Page 2: Programming the CD101. Push and hold the SET button for 3 seconds
Page 3: Programming the CD101. Push and hold the SET button for 3 seconds

Push and hold the SET button for 3 seconds

Page 4: Programming the CD101. Push and hold the SET button for 3 seconds

AL1 will appear. Keep pressing the SET button until you see LCK

Page 5: Programming the CD101. Push and hold the SET button for 3 seconds

The default value of LCK will be 1000. We need to change this value to unlock the thermocouple settings.

Page 6: Programming the CD101. Push and hold the SET button for 3 seconds

Change the value of LCK to 1100. You can use the < key to change the cursor position. Press

SET again until you have exited the menu.

Page 7: Programming the CD101. Push and hold the SET button for 3 seconds

(back to the normal operation screen)

Page 8: Programming the CD101. Push and hold the SET button for 3 seconds

Push and hold SET and < together

Page 9: Programming the CD101. Push and hold the SET button for 3 seconds

Set the value of Cod to 0000

Page 10: Programming the CD101. Push and hold the SET button for 3 seconds

Change the value of SL1 to 1100 for the pt100 thermocouple

Page 11: Programming the CD101. Push and hold the SET button for 3 seconds

Press and hold SET and < to return to normal operation

Page 12: Programming the CD101. Push and hold the SET button for 3 seconds

Normal operation

Page 13: Programming the CD101. Push and hold the SET button for 3 seconds

Push and hold the SET button for 3 seconds

Page 14: Programming the CD101. Push and hold the SET button for 3 seconds

Keep pressing SET until you see LCK. Set the value to 1000. Press and hold SET to exit the

menu.

Page 15: Programming the CD101. Push and hold the SET button for 3 seconds

Normal operation

Page 16: Programming the CD101. Push and hold the SET button for 3 seconds

Setting the desired temperature

Page 17: Programming the CD101. Push and hold the SET button for 3 seconds

Press and release the SET button. The orange numbers on the SV row will flicker. Use the ˄ and ˅ buttons to change the value.

Use the < button to change decimal places. Press SET to confirm.

Page 18: Programming the CD101. Push and hold the SET button for 3 seconds

For additional programming details, see

this manual for the CD101 controller

.