product overview 2014

6
PCIe Storage & Switches

Upload: accusys-storage-ltd

Post on 01-Dec-2014

208 views

Category:

Devices & Hardware


2 download

DESCRIPTION

ExaSAN Product_overview_2014

TRANSCRIPT

Page 1: Product overview 2014

PCIe Storage & Switches

Accusys Korea, Inc.Baegang B/D #801, 666-14 Shinsa-Dong, Kangnam-Gu, Seoul, Korea 135-897TEL: +82-2-6245-9050 SALES: [email protected]

Accusys Beijing Company Ltd.Room 1206 Tower B, Jinmao Building, No. 18 Xizhimenwai Street, Xicheng District, Beijing, China TEL: +86-10-88332622 SALES: [email protected]

Page 2: Product overview 2014

The A12S2-PS The Head node building block for a fast DAS and SAN solution.

The B08S2-PS Compact 8 bay RAID storage using 2.5" disk drives

and weighing just less the 5 kg(11 pounds) .

DASSolutionWhen it comes to Direct Attached

Solutions, Accusys’s ExaSAN family

has led the industry in innovative,

high performance and cost effective

solutions. Easy to install and utilize,

ExaSAN PCIe technology continues

to define and revolutionize storage

standards in the media and

entertainment industries.

The ExaSAN B08S2-PS provides a

compact storage solution that can

be easily transported for field work

and packs a powerful punch when it

comes to performance. The B08S2-PS

can support eight 2.5” SSD or

SAS/SATA hard drives with a total

weight of no more than 5 kg (11

pounds). Unlike other small form

storage, the B08S2-PS takes full

advantage of PCI express protocol throughout the storage path. The 20Gb

PCIe2.0, unlike other interfaces that need time for protocol translating,

eliminates the delays of conversion and reaches 1300 MB/s read and 1100

MB/s write under RAID 5.

ExaSAN A12S2-PS offers high performance, availability and scalability. It features

PCI Express 2.0 technology capable of reaching read speeds in excess of 1200

MB/s with only twelve drives and can easily handle HD (multiple streams), 2K,

dual stereoscopic 3D, 4K and DPX formats. Running 20Gb/sec bandwidth

without protocol conversion, the A12S2-PS storage system makes high speed

shared post-production workflows more affordable than current Fibre Channel

solutions.

The first PCIe3.0 desktop model of the ExaSAN

family, this 8-bay RAID system will support 3.5"

(4TB and above) SAS and SATA drives. It retains the

style and professional design of its predecessor

but has had a major upgrade to its central core. It

now uses PCIe3.0 technology with throughput of

up to 1200MB/s. Expansion is easy – double up

performance with a dual port 3.0 HBA card!

The A08S3-PSThe next-generation 8 bay tower. Innovative

features, faster performance.

Host

RAID

● Redundant power supply (Option)

● Supports RAID 0, 1, 5, 6, 10, JBOD

● PCIe3.0 32Gb bandwidth

● Compatible with 3.5” and 2.5”

SATA/SAS enterprise hard disks

● PCIe SAN ready

Page 3: Product overview 2014

Level 1 SANEasy to con�gure cross-platform SAN �le system shares

data at high speed for collaborative work�ows.

Level 2 SANConnect SAN and DAS with Z2M HBA dual port

NT redrive card.

Level 3 SANBuilding an extra volume to be the data library

for SAN network.

3 levels of Simple SANSolutionA storage area network, or SAN, is a high-speed network

of storage devices connecting to a server or switch to

share its contents with multiple users in a high speed

and secure manner. In a professional workgroup

environment, storage devices + switch + SAN software

are the key ingredients in creating a simple yet effective

way to share your data. This is categorized below in “3

levels of simple SAN “.

ExaSAN is unique in that it has its own Storage, Switch

and SAN software. With all three aspects combined,

we can create what we consider as the ExaSAN’s SAN.

Starting with level 1, the SAN requires the following

setup : Storage ( A12S2 ) + Switch ( *SWF16 V2 ) + SAN

software ( SANit 2 ).

From a SAN environment point of view, you can have

up to 12 clients share file uploads and downloads

simultaneously in a volume based SAN system. This is

your typical SAN environment. Expansion will be

limited.

An enhancement to Level 1 SAN, Level 2 SAN

expands client connectivity. It consists of additional

storage (A12S2) direct attached to the local client for

backup and high bandwidth access. All files

gathered from the main storage will be stored

locally secure for faster processing.

Dual port NT re-drive card.

With the hybrid function of the HBA card, you can

now connect both the SAN network and local DAS

storage with one card. Use one connector from this

dual port Z2M HBA card for connecting to a

A08S3-PS or any other ExaSAN PCIe2.0 storage

device, and the other to a SWF16 V2 or any other

ExaSAN PCIe2.0 switch. You can then immediately

copy footage from your shared storage to the local

DAS and back again at exceptional speed.

Level 3 consists of the entire configuration as we

showed in previous levels but with an additional

sector for backup. We dedicate one client to act as a

backup solution to the online SAN one A12S2 and a

maximum of 3 JBODs attached.

BACKUP

Level 1

Level 2

Level 3

Page 4: Product overview 2014

PCIe Storage & Switches

and more ...

The SWF16 V2World’s �rst PCIe SAN switch with build in MDC and SAN software now with a major upgrade!

Case StudyUpgrading to a Multiple Workstation Editing Work�ow.

ExaSAN SWF16 V2 is the PCIe2.0 switch with additional

advance stability feature. With 16 ports, it allows up to 12

clients to share over 700 terabytes of storage for efficient,

productive, and collaborative workflow. 4 ports are

allocated for ExaSAN storage systems, for instance the 2U, 12bay, A12S2-PS

and JBODs. SWF16 V2 provides 20Gb/s of bandwidth to each client, and

20Gb/s to each storage port through the 20Gb/s QFSP connections. The

maximum capacity that can be shared by the 12 clients is 768TB using 4TB

HDDs, making it the largest PCIe2.0 based SAN available.

The Enterprise SAN range addresses

the need for greater expansion than

can be offered by PCIe technology

alone. With the new HA Appliance

developed especially for ExaSAN we

can create clusters to form an

“unbreakable”, high-availability SAN

network which can deliver either data

migration or mirroring services with

ease...

ExaSAN products are fully compatible

with other SAN software such as

metaSAN from Tiger Technology and

Xsan from Apple.

Want to know more? Please visit our

website: www.exasan.com

A digital intermediate service company would like to design a network

including a Linux workstation ingest video from film scanner, one Windows

for editing, and a Windows server for playout. We suggested adding

A12S2-PS to each host as local DAS, to ensure all the clients have enough

work space to process the DI works.

The Linux machine ingests DPX files from the scanner and direct the raw

images to the DAS volume to compose the loose files to a clip. Then, upload

to the SAN volume to share to the other two seats. The second one

downloads the clips to the local DAS to edit and do video daily for the client.

On the DAS, this seat can own an independent workspace to edit compose

and grading the video, and be capable to create private storage space to

show the daily to client. The Windows server backup the edited clips to its

DAS system with Archiware P5 Backup and send the finished video work out

to external network.

A12S2-PS+A12S2-SJ

SWF16 V2

A12S2-PS A12S2-PS A12S2-PS

Page 5: Product overview 2014

AccessoriesHBA Cards and Cables for PCIe2.0

Z2M — Dual Port QSFP HBA CardExaSAN Z2M card allows you to connect both the SAN

network and local DAS storage with one card, you can

immediately download footage from shared storage to

local DAS then upload back after editing at exceptional

speed.

SANit 2 is a shareable, cross platform storage infrastructure

allowing users to access the same storage pool, extreme

speeds and high reliability. SANit 2 has the following features

to meet your creation condition:

● Designed for post production workflows

● Full-feature SAN Software

● Easy to setup

● Excellent Performance; affordable cost

SANit Feature:

● Single Storage pool co-working and sharing

● Designed for post production workflows

● Three steps to a complete setup

● Excellent Performance; affordable cost

Copper and Optical CablesExaSAN copper and optical cables are high performance

active cables with maximum aggregated bandwidth of

40 Gpbs, from 2 meters up to 100 meters in length.

Optical cables are light weight with a flexible 35mm end

radius, cable diameter of 3.3mm, low incremental power

consumption and low latency.

C1M PCIe to Thunderbolt 2 DAS/ SAN ConverterExaSAN C1M DAS/ SAN converter allows Mac computer

users to connect their Mac to ExaSAN DAS and SAN

solutions. Each C1M converter has one QSFP port and a

Thunderbolt 2 port to transfer ExaSAN’s PCIe to

Thunderbolt with downward compatibility.

SANit 2

Page 6: Product overview 2014

ExaSAN Product Matrix

Storage

Product Image

1212Disk number 8

5 Gb/s x 4Host I/F speed 5 Gb/s x 4

Disk I/F

0, 1, 5, 6, 0+1, JBOD 0, 1, 5, 6, 0+1, JBOD 0, 1, 5, 6, 0+1, JBOD 0, 1, 5, 6, 0+1, JBODRAID level

20 GbBandwidth 20 Gb

LSI 2208CPU type

2GB DDRIII Default memory 1GB DDR III

x 3 JBODJBOD expansion None

QSFP cableCable type QSFP cable

Single port QSFP HBA/Dual port QSFP HBAHBA

2 2Cooling fans 1

400W x 2 (Redundant) 400W x 2 (Redundant)Power supply 150W

YesGUI RAID Manager

YesS.M.A.R.T

Yes Yes

YesYes

2U Rackmount 2U RackmountForm Factor 8.7 x 17.5 x 26.5 cm

Yes

Yes

40 Gb

8

20 Gb

QSFP cable

QSFP cable

Intel Processor

512 MB DDR II

4

20 Gb

192

120W

8.7 x 17.5 x 26.5 cm

Product Image

Max Bandwidth

Support Host No.

Host port speed

Host Switch cable

Support storage No.

Storage port speed

SAN max disk No.

Switch-Storage cable

CPU type

Default memory

Power supply

Web GUI Manager

Lun Masking

MDC function

SANit Software

Form Factor 1U Rackmount

80Gb

12

20Gb

QSFP cable

4

20Gb

192

QSFP cable

Intel Processor

1GB DDRIII

1U Rackmount

80Gb

12

20Gb

QSFP cable

4

20Gb

192

QSFP cable

Intel Processor

1 GB DDRIII

Redundant power supply (220W x 2)

Yes

Yes

Yes

No

Yes

Yes

No

No

No

No

SAS/SATASAS/SATASAS/SATASAS/SATA

LSI 2208

Single port QSFP HBA / Dual port QSFP HBA

6Gb/s x 4

6 Gb x 4

None

None

None

6Gb mini SAS cable

None

RAID System Providerfor Media and Entertainment Industry

www.exasan.com

TAIWAN - Headquarters9F-2., No.8, Taiyuan 1St. St., Jhubei City, Hsinchu Country 302, Taiwan TEL: +886-3-560-0258 SALES: [email protected]

Accusys Korea, Inc.Baegang B/D #801, 666-14 Shinsa-Dong, Kangnam-Gu, Seoul, Korea 135-897TEL: +82-2-6245-9050 SALES: [email protected]

Accusys Beijing Company Ltd.Room 1206 Tower B, Jinmao Building, No. 18 Xizhimenwai Street, Xicheng District, Beijing, China TEL: +86-10-88332622 SALES: [email protected]

Model Name A12S2-PS

8

B08S2-PS

8 Gb/s x 4

32 Gb

2GB DDR III

None

QSFP cable

1

Yes

Yes

50.2 x 29.1 x 55.7 cm

LSI 2208

Single port QSFP HBA / Dual port QSFP HBA

300W / Redundant 300W PSU ( optional )

A08S3-PSA12S2-SJ

Generation PCIe2.0 PCIe2.0 PCIe3.0 PCIe2.0

SW16 SWF16 V2Model Name SW08-Q4

Switch

Support storage system A12S2-PS + A12S2-SJ A12S2-PS + A12S2-SJ+B08S2-PS

Generation PCIe2.0 PCIe2.0 PCIe2.0