product data sheet february 2015 sd 3100-0e05 damcos dphs ... · february 2015 damcos dphs, phs and...

8
Product Data Sheet June 2020 SD 3100-0E07 Damcos DPHS, PHS and P3 Accessories for Valve/Actuator Area DPHS PHS P3

Upload: others

Post on 25-Jun-2020

6 views

Category:

Documents


0 download

TRANSCRIPT

Page 1: Product Data Sheet February 2015 SD 3100-0E05 Damcos DPHS ... · February 2015 Damcos DPHS, PHS and P3 3 Technical Specification PHS Block Hydraulic diagram PHS P3 PHS - bleed fail

Product Data SheetJune 2020

SD 3100-0E07

Damcos™ DPHS, PHS and P3Accessories for Valve/Actuator Area

DPHS

PHS

P3

Page 2: Product Data Sheet February 2015 SD 3100-0E05 Damcos DPHS ... · February 2015 Damcos DPHS, PHS and P3 3 Technical Specification PHS Block Hydraulic diagram PHS P3 PHS - bleed fail

Damcos™ DPHS, PHS and P3 June 2020

2

Unit Description Typical Application

PHS Pipe Block Block with single quick connection and stop valve. The block has connection tread G3/8” or G1/4”.

For emergency operation of 1-line actua-tors (spring return) by means of portable hand pump. The block is pipe mounted.

P3 Cross-Over Plate Plate for cross - connecting ports P and A, respectively B and T of a Cetop-3/NG 6 stack.

Whenever a Cetop-3/NG 6 mounting block is used for mounting of control equipment on the actuator, a P3 plate is necessary to close the Cetop-3 “sand-wich”.

PHS Bleeder Fail Close, submerged Bleed pipe from actuator can be con-nected to block.

For emergency operation of 1-line sub-merged actuator (fail close) by means of portable hand pump. The block is pipe mounted.

PHS Bleeder Fail Open, submerged Bleed pipe from actuator can be con-nected to block.

For emergency operation of 1-line sub-merged actuator (fail open) by means of portable hand pump. The block is pipe mounted.

DPHS Pipe Block, submerged For emergency operation of 2-line actua-tor by means of portable hand pump. The block is pipe mounted.

For emergency operation of 2-line actua-tor or system consisting LPU, both S and D, by means of portable hand pump.

DPHS Flushing Block for Manifold Used for shutting off connections to manifold when flushing or connecting and operating actuators by portable hand pump from outside the deck-box. The block has connection tread G3/8” (G1/4” in manifolds).Two versions one for brass manifold and one for acid proof manifold.Installation requirements: Damcos Brass manifold or acid proof manifold 75 mm pitch only.

For use of shutting off connection to manifold when flushing, connecting and operating actuators by portable hand pump from outside the deck-box.

DescriptionThe following accessories for valve and actuator area are available for typical applications as described below.

643

533

2014,5

6912

49

1130

1324

38

18

PHS-Block G1/4"

G3/8” G1/4”

49

14

26

60

4071

,5

1138

1640

1138

14

30

41,5

7,5

PHS-Block with bleeder, Fail Close

4927

14

26

60

4071

,5

30

41,5

7,511

38

1640

PHS-bleeder fail open

49

14

26

60

4071

,5

7,541,5

3060

1640

1138

1138

DPHS-Block

Page 3: Product Data Sheet February 2015 SD 3100-0E05 Damcos DPHS ... · February 2015 Damcos DPHS, PHS and P3 3 Technical Specification PHS Block Hydraulic diagram PHS P3 PHS - bleed fail

Damcos™ DPHS, PHS and P3June 2020

3

Technical Specification

PHS PHSPHS - bleed

fail closePHS - bleed

fail openDPHS

pipe block

DPHS* flushing block

Brass / SS

Maximum operation pressure 135 bar/2000 PSI

Maximum test pressure 225 bar/3250 PSI

Flow rate at 100 bar (50 cSt visc.) l/min

6 20 6 6 6 7/5

Temperature range -20°C to +80°C

Weight approx. kg/lb 0.6 / 1.3 0.2 / 0.4 1.1 / 2.4 1.1 / 2.4 1.1 / 2.4 1.6 / 3.5

Seals NBR

HousingMS 58 or AISI 316L

MS 58 MS 58 MS 58 MS 58 MS 58 / AISI 316L

Screws None None None None None MS 58 / AISI 316L

Quick connectionMS 58 or AISI 316L

MS 58 MS 58 MS 58 MS 58 MS 58 / AISI 316L

*) Versions made for 60 bar is good for burst pressure 445 bar!

Hydraulic Diagram

PHS Block

Page 4: Product Data Sheet February 2015 SD 3100-0E05 Damcos DPHS ... · February 2015 Damcos DPHS, PHS and P3 3 Technical Specification PHS Block Hydraulic diagram PHS P3 PHS - bleed fail

Damcos™ DPHS, PHS and P3 June 2020

4

Hydraulic Diagram

PHS Block with a Bleeder for Fail Close

PHS Block with a Bleeder for Fail Ppen

Page 5: Product Data Sheet February 2015 SD 3100-0E05 Damcos DPHS ... · February 2015 Damcos DPHS, PHS and P3 3 Technical Specification PHS Block Hydraulic diagram PHS P3 PHS - bleed fail

Damcos™ DPHS, PHS and P3June 2020

5

DPHS Flushing Block for Manifold

Page 6: Product Data Sheet February 2015 SD 3100-0E05 Damcos DPHS ... · February 2015 Damcos DPHS, PHS and P3 3 Technical Specification PHS Block Hydraulic diagram PHS P3 PHS - bleed fail

Damcos™ DPHS, PHS and P3 June 2020

6

Hydraulic Diagram

PHS

PHS Pipe Block G3/8” PHS Pipe Block G1/4”

PHS Bleeder Fail Open PHS Bleeder Fail Close

Page 7: Product Data Sheet February 2015 SD 3100-0E05 Damcos DPHS ... · February 2015 Damcos DPHS, PHS and P3 3 Technical Specification PHS Block Hydraulic diagram PHS P3 PHS - bleed fail

Damcos™ DPHS, PHS and P3June 2020

7

P3 DPHS Pipe Block

DPHS Mounting on Manifold

Page 8: Product Data Sheet February 2015 SD 3100-0E05 Damcos DPHS ... · February 2015 Damcos DPHS, PHS and P3 3 Technical Specification PHS Block Hydraulic diagram PHS P3 PHS - bleed fail

Product Data SheetJune 2020

Damcos™ DPHS, PHS and P3SD 3100-0E07

©2020 Emerson. All rights reserved.

The Emerson logo is a trademark and service mark of Emerson Electric Co. Damcos and the Damcos logotype are trademarks of Damcos A/S. Damcos is a member of the Emerson family of companies. All other marks are the property of their respective owners.

The contents of this publication are presented for information purposes only, and while effort has been made to ensure their accuracy, they are not to be construed as warranties or guarantees, expressed or implied, regarding the products or services described herein or their use or applicability. Standard Terms and Conditions of Sale can be issued by contacting Damcos A/S. We reserve the right to modify or improve the designs and specifications of our products at any time without notice. Damcos A/S accepts no responsibility for any errors that may appear in this publication.

Emerson Automation SolutionsDamcos A/S Aaderupvej 41 DK-4700 Naestved T +45 5578 7200 F +45 5578 7272