process of reverse osmosis plant raw water feed pump: raw water pump is used to feed the water to...
TRANSCRIPT
![Page 1: Process Of Reverse Osmosis Plant Raw Water Feed Pump: Raw Water pump is used to feed the water to Filtration System at required Pressure from water source](https://reader036.vdocuments.us/reader036/viewer/2022062511/5515d99d550346cf6f8b49fa/html5/thumbnails/1.jpg)
Process Of Reverse Osmosis Plant
![Page 2: Process Of Reverse Osmosis Plant Raw Water Feed Pump: Raw Water pump is used to feed the water to Filtration System at required Pressure from water source](https://reader036.vdocuments.us/reader036/viewer/2022062511/5515d99d550346cf6f8b49fa/html5/thumbnails/2.jpg)
Raw Water Feed Pump: Raw Water pump is used to feed the water to Filtration System at required Pressure from water source.
Raw Water Tank
To Filtration System
Raw Water Pump
Source of Water
Feeding Water
![Page 3: Process Of Reverse Osmosis Plant Raw Water Feed Pump: Raw Water pump is used to feed the water to Filtration System at required Pressure from water source](https://reader036.vdocuments.us/reader036/viewer/2022062511/5515d99d550346cf6f8b49fa/html5/thumbnails/3.jpg)
Pressure Sand Filter
Activated Carbon Filter
Pressure Sand Filter : PSF consist of FRP / MS / SS Vessel with Frontal Pipe, Multi Port Valve or Conventional Valve, also media layer of Pebbles, Gravels, Cylex, Sand Media. PSF is used for reduction of suspended solids.
Activated Carbon Filter : ACF consist of FRP / MS / SS Vessel with frontal pipe, Multi port Valve or Conventional Valve, & Activated Carbon layer. ACF is used for reduction of organic maters & chlorine.
From Raw Water Pump
To Dosing
Filtration System
![Page 4: Process Of Reverse Osmosis Plant Raw Water Feed Pump: Raw Water pump is used to feed the water to Filtration System at required Pressure from water source](https://reader036.vdocuments.us/reader036/viewer/2022062511/5515d99d550346cf6f8b49fa/html5/thumbnails/4.jpg)
Dosing Systems : Dosing Systems are mainly used for the prevention of Scale formation by using Anti Scalant Chemicals. Other Dosing Systems are Chlorination, De chlorination, PH Dosing, SMBS, Acid Dosing etc…
From Filtration System To Micron Cartridge Filter
Dosing System
![Page 5: Process Of Reverse Osmosis Plant Raw Water Feed Pump: Raw Water pump is used to feed the water to Filtration System at required Pressure from water source](https://reader036.vdocuments.us/reader036/viewer/2022062511/5515d99d550346cf6f8b49fa/html5/thumbnails/5.jpg)
From Dosing System To High Pressure Pump
Micron Cartridge Filter
MCF: MCF are used to filter out Physical Impurities in micron rating from feed water.
![Page 6: Process Of Reverse Osmosis Plant Raw Water Feed Pump: Raw Water pump is used to feed the water to Filtration System at required Pressure from water source](https://reader036.vdocuments.us/reader036/viewer/2022062511/5515d99d550346cf6f8b49fa/html5/thumbnails/6.jpg)
From High Cartridge Filter To Reverse Osmosis Module
High Pressure Pump
High pressure Pump: HPP is mainly used to transfer pre-treated water to RO module at required pressure.
![Page 7: Process Of Reverse Osmosis Plant Raw Water Feed Pump: Raw Water pump is used to feed the water to Filtration System at required Pressure from water source](https://reader036.vdocuments.us/reader036/viewer/2022062511/5515d99d550346cf6f8b49fa/html5/thumbnails/7.jpg)
From High Pressure Pump
Product Water
Reverse Osmosis Module
Product Water Tank
Product Water Tank
Reject Water Tank
Reject Water Tank
![Page 8: Process Of Reverse Osmosis Plant Raw Water Feed Pump: Raw Water pump is used to feed the water to Filtration System at required Pressure from water source](https://reader036.vdocuments.us/reader036/viewer/2022062511/5515d99d550346cf6f8b49fa/html5/thumbnails/8.jpg)
Our Control Panel
Online Conductivity Meter
Auto-Manual Switch
Volt-Ampere Meter
Product & Reject Flow Meter
Pressure Gauge
Feed Pump Switches
High Pressure Pump Switches
![Page 9: Process Of Reverse Osmosis Plant Raw Water Feed Pump: Raw Water pump is used to feed the water to Filtration System at required Pressure from water source](https://reader036.vdocuments.us/reader036/viewer/2022062511/5515d99d550346cf6f8b49fa/html5/thumbnails/9.jpg)
RO Applications
•Boiler Feed water Treatment•Food & Beverage•Power Generation Industries•Sea water Desalination•Recycling Industrial Effluent & Domestic Sewage•Pharmaceutical industries •Chemical & Dyes Industries•Pulp & Paper Industries•Drinking Water Application
![Page 10: Process Of Reverse Osmosis Plant Raw Water Feed Pump: Raw Water pump is used to feed the water to Filtration System at required Pressure from water source](https://reader036.vdocuments.us/reader036/viewer/2022062511/5515d99d550346cf6f8b49fa/html5/thumbnails/10.jpg)
Some of our RO Plants
![Page 11: Process Of Reverse Osmosis Plant Raw Water Feed Pump: Raw Water pump is used to feed the water to Filtration System at required Pressure from water source](https://reader036.vdocuments.us/reader036/viewer/2022062511/5515d99d550346cf6f8b49fa/html5/thumbnails/11.jpg)
Thank You