primergy sx960 s1 storage blade - operating...

74
Operating Manual - English PRIMERGY SX960 S1 Storage Blade Operating Manual April 2014

Upload: buitram

Post on 03-Apr-2018

218 views

Category:

Documents


1 download

TRANSCRIPT

Page 1: PRIMERGY SX960 S1 Storage Blade - Operating Manualmanuals.ts.fujitsu.com/file/9903/sx960s1-om-en.pdf · The SX960 S1 storage blade can be fitted with a SAS RAID controller. Please

Operating Manual - English

PRIMERGY SX960 S1Storage Blade Operating Manual

April 2014

Page 2: PRIMERGY SX960 S1 Storage Blade - Operating Manualmanuals.ts.fujitsu.com/file/9903/sx960s1-om-en.pdf · The SX960 S1 storage blade can be fitted with a SAS RAID controller. Please

Copyright and Trademarks

Comments… Suggestions… Corrections…The User Documentation Department would like toknow your opinion of this manual. Your feedback helpsus optimize our documentation to suit your individual needs.

Feel free to send us your comments by e-mail to email: [email protected].

Certified documentation according to DIN EN ISO 9001:2008To ensure a consistently high quality standard anduser-friendliness, this documentation was created tomeet the regulations of a quality management system which complies with the requirements of the standardDIN EN ISO 9001:2008.

cognitas. Gesellschaft für Technik-Dokumentation mbHwww.cognitas.de

© c

ogni

tas.

Ges

ells

chft

für T

echn

ik-D

okum

enta

tion

mbH

201

4 P

fad:

C:\P

rogr

amm

e\FC

T\tim

_app

\tim

_loc

al\w

ork\

PIC

HO

L\O

BJ_

DO

KU

-216

98-0

01.fm

Copyright © 2014 Fujitsu Technology Solutions GmbH.

All rights reserved.Delivery subject to availability; right of technical modifications reserved.

All hardware and software names used are trademarks of their respective manufacturers.

– The contents of this manual may be revised without prior notice.

– Fujitsu assumes no liability for damages to third party copyrights or other rights arising from the use of any information in this manual.

– No part of this manual may be reproduced in any without the prior written permission of Fujitsu.

Microsoft, Windows, Windows Server, and Hyper V are trademarks or registered trademarks of Microsoft Corporation in the USA and other countries.

Intel and Xeon are trademarks or registered trademarks of Intel Corporation or its subsidiaries in the USA and other countries.

Page 3: PRIMERGY SX960 S1 Storage Blade - Operating Manualmanuals.ts.fujitsu.com/file/9903/sx960s1-om-en.pdf · The SX960 S1 storage blade can be fitted with a SAS RAID controller. Please

SX960 S1 Operating Manual

Before reading this manual

For your safety

This manual contains important information for safely and correctly using this product.

Carefully read the manual before using this product. Pay particular attention to the accompanying manual "Safety Notes and Regulations" and ensure these safety notes are understood before using the product. Keep this manual and the manual "Safety Notes and Regulations" in a safe place for easy reference while using this product.

Radio interference

This product is a "Class A" ITE (Information Technology Equipment). In a domestic environment this product may cause radio interference, in which case the user may be required to take appropriate measures. VCCI-A

Aluminum electrolytic capacitors

The aluminum electrolytic capacitors used in the product's printed circuit board assemblies and in the mouse and keyboard are limited-life components. Use of these components beyond their operating life may result in electrolyte leakage or depletion, potentially causing emission of foul odor or smoke.

As a guideline, in a normal office environment (25°C) operating life is not expected to be reached within the maintenance support period (5 years). However, operating life may be reached more quickly if, for example, the product is used in a hot environment. The customer shall bear the cost of replacing replaceable components which have exceeded their operating life. Note that these are only guidelines, and do not constitute a guarantee of trouble-free operation during the maintenance support period.

High safety use

This product has been designed and manufactured to be used in commercial and/or industrial areas as a server.

When used as visual display workplace, it must not be placed in the direct field of view to avoid incommoding reflections (applies only to TX server systems).

The device has not been designed or manufactured for uses which demand an extremely high level of safety and carry a direct and serious risk of life or body if such safety cannot be assured.

Page 4: PRIMERGY SX960 S1 Storage Blade - Operating Manualmanuals.ts.fujitsu.com/file/9903/sx960s1-om-en.pdf · The SX960 S1 storage blade can be fitted with a SAS RAID controller. Please

Operating Manual SX960 S1

© c

ogni

tas.

Ges

ells

chft

für T

echn

ik-D

okum

enta

tion

mbH

201

4 P

fad:

C:\P

rogr

amm

e\FC

T\tim

_app

\tim

_loc

al\w

ork\

PIC

HO

L\O

BJ_

DO

KU

-216

98-0

01.fm

These uses include control of nuclear reactions in nuclear power plants, automatic airplane flight control, air traffic control, traffic control in mass transport systems, medical devices for life support, and missile guidance control in weapons systems (hereafter, "high safety use"). Customers should not use this product for high safety use unless measures are in place for ensuring the level of safety demanded of such use. Please consult the sales staff of Fujitsu if intending to use this product for high safety use.

Measures against momentary voltage drop

This product may be affected by a momentary voltage drop in the power supply caused by lightning. To prevent a momentary voltage drop, use of an AC uninterruptible power supply is recommended.

(This notice follows the guidelines of Voltage Dip Immunity of Personal Computer issued by JEITA, the Japan Electronics and Information Technology Industries Association.)

Technology controlled by the Foreign Exchange and Foreign Trade Control Law of Japan

Documents produced by Fujitsu may contain technology controlled by the Foreign Exchange and Foreign Trade Control Law of Japan. Documents which contain such technology should not be exported from Japan or transferred to non-residents of Japan without first obtaining authorization in accordance with the above law.

Harmonic Current Standards

This product conforms to harmonic current standard JIS C 61000-3-2.

Only for the Japanese market:About SATA hard disk drives

The SATA version of this server supports hard disk drives with SATA / BC-SATA storage interfaces. Please note that the usage and operation conditions differ depending on the type of hard disk drive used.

Please refer to the following internet address for further information on the usage and operation conditions of each available type of hard disk drive:

http://primeserver.fujitsu.com/primergy/harddisk/

Page 5: PRIMERGY SX960 S1 Storage Blade - Operating Manualmanuals.ts.fujitsu.com/file/9903/sx960s1-om-en.pdf · The SX960 S1 storage blade can be fitted with a SAS RAID controller. Please

SX960 S1 Operating Manual

Only for the Japanese market:

I Although described in this manual, some sections do not apply to the Japanese market. These options and routines include:

– CSS (Customer Self Service)

Page 6: PRIMERGY SX960 S1 Storage Blade - Operating Manualmanuals.ts.fujitsu.com/file/9903/sx960s1-om-en.pdf · The SX960 S1 storage blade can be fitted with a SAS RAID controller. Please

Operating Manual SX960 S1

© c

ogni

tas.

Ges

ells

chft

für T

echn

ik-D

okum

enta

tion

mbH

201

4 P

fad:

C:\P

rogr

amm

e\FC

T\tim

_app

\tim

_loc

al\w

ork\

PIC

HO

L\O

BJ_

DO

KU

-216

98-0

01.fm

Page 7: PRIMERGY SX960 S1 Storage Blade - Operating Manualmanuals.ts.fujitsu.com/file/9903/sx960s1-om-en.pdf · The SX960 S1 storage blade can be fitted with a SAS RAID controller. Please

SX960 S1 Operating Manual

Contents

1 Preface . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 9

1.1 Concept and target groups for this manual . . . . . . . . . 10

1.2 Documentation overview . . . . . . . . . . . . . . . . . . . 10

1.3 Features . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 11

1.4 Notational conventions . . . . . . . . . . . . . . . . . . . . 11

1.5 Technical data . . . . . . . . . . . . . . . . . . . . . . . . . 12

2 Important notes . . . . . . . . . . . . . . . . . . . . . . . . . 15

2.1 Safety instructions . . . . . . . . . . . . . . . . . . . . . . . 15

2.2 Electrostatic sensitive device label . . . . . . . . . . . . . . 17

2.3 FCC Class A Compliance Statement . . . . . . . . . . . . . 18

2.4 RFI suppression . . . . . . . . . . . . . . . . . . . . . . . . 19

2.5 Notes on transportation . . . . . . . . . . . . . . . . . . . . 19

3 Installation . . . . . . . . . . . . . . . . . . . . . . . . . . . 21

3.1 Installation procedure . . . . . . . . . . . . . . . . . . . . . 22

3.2 Unpacking a storage blade . . . . . . . . . . . . . . . . . . 22

3.3 Installing/removing a storage blade in/from the system unit 23

4 Operation . . . . . . . . . . . . . . . . . . . . . . . . . . . . 31

4.1 Control and display elements . . . . . . . . . . . . . . . . . 31

4.2 Putting the storage blade into operation . . . . . . . . . . . 34

5 Hot-plug components . . . . . . . . . . . . . . . . . . . . . 35

5.1 Hot-plug drives . . . . . . . . . . . . . . . . . . . . . . . . . 35

Page 8: PRIMERGY SX960 S1 Storage Blade - Operating Manualmanuals.ts.fujitsu.com/file/9903/sx960s1-om-en.pdf · The SX960 S1 storage blade can be fitted with a SAS RAID controller. Please

Operating Manual SX960 S1

Contents

© c

ogni

tas.

Ges

ells

chft

für T

echn

ik-D

okum

enta

tion

mbH

201

4 P

fad:

C:\P

rogr

amm

e\FC

T\tim

_app

\tim

_loc

al\w

ork\

PIC

HO

L\O

BJ_

DO

KU

-216

99-0

01.fm

5.2 Removing/installing the dummy module . . . . . . . . . . . . 37

5.3 Installing/removing the HDD/SSD module . . . . . . . . . . . 39

6 Optional: Installation / Replacement of BBU / FBU . . . . . . 43

6.1 Installing the BBU07/08 . . . . . . . . . . . . . . . . . . . . . 446.1.1 Preparations . . . . . . . . . . . . . . . . . . . . . . . . . . . 446.1.2 Mounting the BBU07 . . . . . . . . . . . . . . . . . . . . . . . 526.1.3 Mounting the BBU08 . . . . . . . . . . . . . . . . . . . . . . . 57

6.2 Installing the FBU . . . . . . . . . . . . . . . . . . . . . . . . 606.2.1 Preparations . . . . . . . . . . . . . . . . . . . . . . . . . . . 606.2.2 Mounting the FBU . . . . . . . . . . . . . . . . . . . . . . . . . 64

6.3 Replacing the BBU07/08 . . . . . . . . . . . . . . . . . . . . 676.3.1 Removing the BBU07/08 . . . . . . . . . . . . . . . . . . . . . 676.3.2 Installing the BBU07/08 . . . . . . . . . . . . . . . . . . . . . . 69

6.4 Replacing the FBU . . . . . . . . . . . . . . . . . . . . . . . . 706.4.1 Removing the FBU . . . . . . . . . . . . . . . . . . . . . . . . 706.4.2 Installing the FBU . . . . . . . . . . . . . . . . . . . . . . . . . 72

7 Troubleshooting and tips . . . . . . . . . . . . . . . . . . . . 73

7.1 Drives reported as "dead" when starting system . . . . . . . 73

7.2 Added drive reported as defective . . . . . . . . . . . . . . . 74

Page 9: PRIMERGY SX960 S1 Storage Blade - Operating Manualmanuals.ts.fujitsu.com/file/9903/sx960s1-om-en.pdf · The SX960 S1 storage blade can be fitted with a SAS RAID controller. Please

SX960 S1 Operating Manual 9

1 PrefaceThe PRIMERGY SX960 S1 storage blade is used as a storage subsystem for the PRIMERGY BX400 S1 and BX900 S1/BX900 S2 blade server.

The storage blade comes with 10 bays for 2.5-inch SAS or SATA HDD/SSD modules and occupies two bays in the system unit. Up to two SX960 S1 storage blades can be installed per BX400 S1 and BX900 S1/BX900 S2 system unit.

Figure 1: PRIMERGY SX960 S1 storage blade

Page 10: PRIMERGY SX960 S1 Storage Blade - Operating Manualmanuals.ts.fujitsu.com/file/9903/sx960s1-om-en.pdf · The SX960 S1 storage blade can be fitted with a SAS RAID controller. Please

10 Operating Manual SX960 S1

Preface

© c

ogni

tas.

Ges

ells

chft

für T

echn

ik-D

okum

enta

tion

mbH

201

4 P

fad:

C:\P

rogr

amm

e\FC

T\tim

_app

\tim

_loc

al\w

ork\

PIC

HO

L\O

BJ_

DO

KU

-217

00-0

01.fm

1.1 Concept and target groups for this manual

This operating manual describes how to install, set up and operate your storage blade. It is intended for those responsible for installing the hardware and ensuring that the system runs smoothly. This operating manual contains all the information you need to put your PRIMERGY SX960 S1 storage blade into operation.

To understand the various expansion options, you will need to be familiar with the fields of hardware and data transmission and you will require a basic knowledge of the underlying operating system.

1.2 Documentation overview

More information on your PRIMERGY SX960 S1 storage blade can be found in the following documents:

– "Safety Notes and Regulations" manual" 安全上のご注意 " for the Japanese market

– "Warranty" manual" 保証書 " for the Japanese market

– "Returning used devices" manual and "Service Desk" leaflet" サポート&サービス " for the Japanese market

I All documentation on PRIMERGY hardware and ServerView software is available online from the Fujitsu manuals server at:

– http://manuals.ts.fujitsu.com (global market)– http://jp.fujitsu.com/platform/server/primergy/manual (Japanese market)

The complete PRIMERGY documentation set can also be downloaded as a DVD ISO image at:

– ftp://ftp.ts.fujitsu.com/images/serverview/manuals (global market)– http://jp.fujitsu.com/primergy/downloads (Japanese market)

Page 11: PRIMERGY SX960 S1 Storage Blade - Operating Manualmanuals.ts.fujitsu.com/file/9903/sx960s1-om-en.pdf · The SX960 S1 storage blade can be fitted with a SAS RAID controller. Please

SX960 S1 Operating Manual 11

Preface

1.3 Features

The PRIMERGY SX960 S1 storage blade comes with the following features:

MegaRAID SAS ControllerThe SX960 S1 storage blade can be fitted with a SAS RAID controller. Please refer to the configurator for details.

Battery Backup Unit / Flash Backup UnitA Battery Backup Unit (BBU) / Flash Backup Unit (FBU) can optionally be ordered for certain RAID controllers to back up the memory contents of the RAID controller in the event of power failure.

1.4 Notational conventions

The following notational conventions are used in this manual:

Text in italics indicates commands or menu items."Quotation marks" indicate names of chapters and terms that are being

emphasized.Ê describes activities that must be performed in the order

shown.V CAUTION! pay particular attention to texts marked with this symbol.

Failure to observe this warning may endanger your life, destroy the system or lead to the loss of data.

I indicates additional information, notes and tips.

Page 12: PRIMERGY SX960 S1 Storage Blade - Operating Manualmanuals.ts.fujitsu.com/file/9903/sx960s1-om-en.pdf · The SX960 S1 storage blade can be fitted with a SAS RAID controller. Please

12 Operating Manual SX960 S1

Preface

© c

ogni

tas.

Ges

ells

chft

für T

echn

ik-D

okum

enta

tion

mbH

201

4 P

fad:

C:\P

rogr

amm

e\FC

T\tim

_app

\tim

_loc

al\w

ork\

PIC

HO

L\O

BJ_

DO

KU

-217

00-0

01.fm

1.5 Technical data

Electrical data

Compliance with regulations and standards

Energy consumption 70W typ. / 110W max. (fully equipped) Heat dissipation 239 BTU/h or 252kJ/h typ./

376 BTU/h or 396kJ/h max.

Product safety and ergonomicsInternational IEC 60950-1/2Europe

Safety EN 60950-1/2ergonomics ISO 9241-3

EN 2941-3EK1-ITB 2003:2007UL 60950-1/2

USA / Canada CSA-C22.2 60950-1-03Taiwan CNS 14336China GB 4943

Electromagnetic compatibilityInternational CISPRA 24Europe EN 55022

EN 55024EN 61000-3-2EN 61000-3-3ETS 300386

USA / Canada 47CFR part 15 Class A / ICES-003Taiwan CNS 13438 Class AChina GB 9245 / GB 17625Japan VCCI Class A / Jeida

CE marking to EU directives

Low Voltage Directive 2006/95/EC Electromagnetic compatibility 2004/108/EC

Page 13: PRIMERGY SX960 S1 Storage Blade - Operating Manualmanuals.ts.fujitsu.com/file/9903/sx960s1-om-en.pdf · The SX960 S1 storage blade can be fitted with a SAS RAID controller. Please

SX960 S1 Operating Manual 13

Preface

Certification

Mechanical specifications

Weight

Max. 8 kg (fully equipped)

Ambient conditions

Condensation during operation must be avoided!

Product safetyGlobal CBEurope ENECGermany GS, CEUSA/Canada CSAUS / CSAC

Japan VCCIChina/Taiwan BSMI

Height 204 mm (chassis height 210.5 mm)Depth 508 mm (525 mm incl. lever)Width 90.5 mm (2 bays in the system unit)

Environment class 3K2Environment class 2K2

EN 60721 / IEC 721 Part 3-3EN 60721 / IEC 721 Part 3-2

Temperature:Operation (3K2) 5°C ... 35°CTransport (2K2) -20°C ... 60°C

Humidity 10% ... 85% (non condensing)

Page 14: PRIMERGY SX960 S1 Storage Blade - Operating Manualmanuals.ts.fujitsu.com/file/9903/sx960s1-om-en.pdf · The SX960 S1 storage blade can be fitted with a SAS RAID controller. Please

14 Operating Manual SX960 S1

Preface

© c

ogni

tas.

Ges

ells

chft

für T

echn

ik-D

okum

enta

tion

mbH

201

4 P

fad:

C:\P

rogr

amm

e\FC

T\tim

_app

\tim

_loc

al\w

ork\

PIC

HO

L\O

BJ_

DO

KU

-217

00-0

01.fm

Page 15: PRIMERGY SX960 S1 Storage Blade - Operating Manualmanuals.ts.fujitsu.com/file/9903/sx960s1-om-en.pdf · The SX960 S1 storage blade can be fitted with a SAS RAID controller. Please

SX960 S1 Operating Manual 15

2 Important notesThis chapter provides safety instructions which you must observe when handling your storage blade.

2.1 Safety instructions

I The following safety instructions are also provided in the manual "Safety Notes and Regulations" or " 安全上のご注意 ".

This device meets the relevant safety regulations for IT equipment. If you have any questions about whether you can install the storage blade in the intended environment, please contact your sales outlet or our customer service team.

V CAUTION!

● The actions described in this manual should only be performed by technical specialists.

● Equipment repairs should only be performed by service staff.

● Any failure to observe the guidelines in this manual, and any unauthorized opening or improper repairs could expose the user to risks (electric shock, fire hazards) or damage the equipment.

● Please note that any unauthorized opening of the storage blade will void the warranty and exempt the manufacturer from all liability.

● During installation and before operating the device, observe the instructions on environmental conditions for your device (see section "Technical data" on page 12)

● If the storage blade has been moved from a cold environment, condensation may form both inside and on the outside of the machine.

Wait until the storage blade has acclimatized to room temperature and is absolutely dry before starting it up. Material damage may be caused to the device if this requirement is not met.

Page 16: PRIMERGY SX960 S1 Storage Blade - Operating Manualmanuals.ts.fujitsu.com/file/9903/sx960s1-om-en.pdf · The SX960 S1 storage blade can be fitted with a SAS RAID controller. Please

16 Operating Manual SX960 S1

Important notes

© c

ogni

tas.

Ges

ells

chft

für T

echn

ik-D

okum

enta

tion

mbH

201

4 P

fad:

C:\P

rogr

amm

e\FC

T\tim

_app

\tim

_loc

al\w

ork\

PIC

HO

L\O

BJ_

DO

KU

-217

01-0

01.fm

V CAUTION!

● Only transport the device in its original packaging or in suitable packaging which protects it from knocks and jolts.For the Japanese market, transporting the device with ORIGINAL PACKAGING is not applied.

● Check that the rated voltage specified on the device's ID plate is the same as the local line voltage.

● Never connect or disconnect data transmission lines during a storm (lightning hazard).

● Make sure that no objects (e.g. bracelets or paper clips) fall into or liquids spill into the device (risk of electric shock or short circuit).

● Note that proper operation of the system (in accordance with IEC 60950-1/DIN EN 60950-1) is guaranteed only if slot covers are installed on all vacant slots and/or dummies on all vacant bays and the housing cover is fitted (cooling, fire protection, RFI suppression).

Page 17: PRIMERGY SX960 S1 Storage Blade - Operating Manualmanuals.ts.fujitsu.com/file/9903/sx960s1-om-en.pdf · The SX960 S1 storage blade can be fitted with a SAS RAID controller. Please

SX960 S1 Operating Manual 17

Important notes

2.2 Electrostatic sensitive device label

Modules with electrostatic-sensitive components

Systems and components that might be damaged by electrostatic discharge (ESD) are marked with the following label:

Figure 2: ESD label

When you handle components fitted with ESDs, you must observe the following points under all circumstances:

● Remove the power plug before installing or removing components containing ESDs.

● You must always discharge yourself of static charges (e.g. by touching a grounded object) before working.

● The equipment and tools you use must be free of static charges.

● Only touch the components at the positions highlighted in green (touch points).

● Do not touch any exposed pins or conductors on a component.

● Use a grounding cable designed for this purpose to connect yourself to the system unit as you install components.

● Place all components on a static-safe base.

I You will find a detailed description for handling ESD components in the relevant European or international standards (DIN EN 61340-5-1, ANSI/ESD S20.20).

Page 18: PRIMERGY SX960 S1 Storage Blade - Operating Manualmanuals.ts.fujitsu.com/file/9903/sx960s1-om-en.pdf · The SX960 S1 storage blade can be fitted with a SAS RAID controller. Please

18 Operating Manual SX960 S1

Important notes

© c

ogni

tas.

Ges

ells

chft

für T

echn

ik-D

okum

enta

tion

mbH

201

4 P

fad:

C:\P

rogr

amm

e\FC

T\tim

_app

\tim

_loc

al\w

ork\

PIC

HO

L\O

BJ_

DO

KU

-217

01-0

01.fm

2.3 FCC Class A Compliance Statement

If there is an FCC statement on the device, it applies to the products covered in this manual, unless otherwise specified herein. The statement for other products will appear in the accompanying documentation.

NOTE:

This equipment has been tested and found to comply with the limits for a "Class A" digital device, pursuant to Part 15 of the FCC rules and meets all requirements of the Canadian Interference-Causing Equipment Standard ICES-003 for digital apparatus. These limits are designed to provide reasonable protection against harmful interference in a residential installation. This equipment generates, uses and can radiate radio frequency energy and, if not installed and used in strict accordance with the instructions, may cause harmful interference to radio communications. However, there is no warranty that interference will not occur in a particular installation. If this equipment does cause harmful interference to radio or television reception, which can be determined by turning the equipment off and on, the user is encouraged to try to correct the interference by one or more of the following measures:

● Reorient or relocate the receiving antenna.

● Increase the separation between equipment and the receiver.

● Connect the equipment into an outlet on a circuit different from that to which the receiver is connected.

● Consult the dealer or an experienced radio/TV technician for help.

Fujitsu is not responsible for any radio or television interference caused by unauthorized modifications of this equipment or the substitution or attachment of connecting cables and equipment other than those specified by Fujitsu. The correction of interferences caused by such unauthorized modification, substitution or attachment will be the responsibility of the user.

The use of shielded I/O cables is required when connecting this equipment to any and all optional peripheral or host devices. Failure to do so may violate FCC and ICES rules.

WARNING:

This is a class A product. In a domestic environment this product may cause radio interference in which case the user may be required to take adequate measures.

Page 19: PRIMERGY SX960 S1 Storage Blade - Operating Manualmanuals.ts.fujitsu.com/file/9903/sx960s1-om-en.pdf · The SX960 S1 storage blade can be fitted with a SAS RAID controller. Please

SX960 S1 Operating Manual 19

Important notes

2.4 RFI suppression

All other equipment which is connected to this product must also have radio noise suppression in accordance with EC Guideline 89/336/EEC.

Products which meet this requirement are accompanied by a certificate to that effect issued by the manufacturer and/or bear the CE mark. Products which do not meet this requirement may be operated only with the special permission of the BZT (Bundesamt für Zulassungen in der Telekommunikation).

2.5 Notes on transportation

I Only transport the storage blade in its original packaging or in suitable packaging which protects it from knocks and jolts.For the Japanese market, transporting the device with ORIGINAL PACKAGING is not applied.

Do not unpack the storage blade until it is at its installation location.

Page 20: PRIMERGY SX960 S1 Storage Blade - Operating Manualmanuals.ts.fujitsu.com/file/9903/sx960s1-om-en.pdf · The SX960 S1 storage blade can be fitted with a SAS RAID controller. Please

20 Operating Manual SX960 S1

Important notes

© c

ogni

tas.

Ges

ells

chft

für T

echn

ik-D

okum

enta

tion

mbH

201

4 P

fad:

C:\P

rogr

amm

e\FC

T\tim

_app

\tim

_loc

al\w

ork\

PIC

HO

L\O

BJ_

DO

KU

-217

01-0

01.fm

Page 21: PRIMERGY SX960 S1 Storage Blade - Operating Manualmanuals.ts.fujitsu.com/file/9903/sx960s1-om-en.pdf · The SX960 S1 storage blade can be fitted with a SAS RAID controller. Please

SX960 S1 Operating Manual 21

3 InstallationV CAUTION!

● Follow the safety instructions in chapter "Important notes" on page 15.

● The storage blade should not be subjected to any extreme environmental conditions (see section "Technical data" on page 12). Protect the storage blade from dust, humidity and heat.

● Make sure that the storage blade is acclimatized for the time indicated in this table before putting it into operation.

In table "Acclimatization time", the temperature difference refers to the difference between the operating environment temperature and the temperature to which the storage blade was exposed previously (outside, transport or storage temperature).

Temperature difference (°C) Minimum acclimatization time(hours)

5 310 515 720 825 930 10

Table 1: Acclimatization time

Page 22: PRIMERGY SX960 S1 Storage Blade - Operating Manualmanuals.ts.fujitsu.com/file/9903/sx960s1-om-en.pdf · The SX960 S1 storage blade can be fitted with a SAS RAID controller. Please

22 Operating Manual SX960 S1

Installation

© c

ogni

tas.

Ges

ells

chft

für T

echn

ik-D

okum

enta

tion

mbH

201

4 P

fad:

C:\P

rogr

amm

e\FC

T\tim

_app

\tim

_loc

al\w

ork\

PIC

HO

L\O

BJ_

DO

KU

-217

02-0

01.fm

3.1 Installation procedure

Ê Unpacking a storage blade (see the next section on this page).

Ê Installing a storage blade in the system unit (see section "Installing/removing a storage blade in/from the system unit" on page 23).

Ê Putting a storage blade into operation (see section "Putting the storage blade into operation" on page 34 in the chapter "Installation and operation").

3.2 Unpacking a storage blade

V CAUTION!

Follow the safety instructions in chapter "Important notes" on page 15.

Do not unpack the storage blade until it is at its installation location.

You should retain the original packaging of the storage blade for possible further transport.

Ê Transport the storage blade to the place where you want to set it up.

Ê Unpack all individual parts.

Keep the original packaging in case you want to transport the storage blade again (applies only to EMEA market).

Ê Check the delivery for any damage during transport.

Ê Check whether the items delivered match the details on the delivery note.

The product name and serial number of the product can be found on the ID card (see section "Indicators on the storage blade" on page 31).

Ê Notify your supplier immediately should you discover that the items delivered do not correspond to the delivery note.

Page 23: PRIMERGY SX960 S1 Storage Blade - Operating Manualmanuals.ts.fujitsu.com/file/9903/sx960s1-om-en.pdf · The SX960 S1 storage blade can be fitted with a SAS RAID controller. Please

SX960 S1 Operating Manual 23

Installation

3.3 Installing/removing a storage blade in/from the system unit

V CAUTION!

Follow the safety instructions in chapter "Important notes" on page 15.

Fitting rules

● A mix of SAS and SATA drives within the SX960 S1 storage blade is not allowed.

● A maximum of two SX960 S1 storage blades can be installed into a system unit (BX400 S1 and BX900 S1/BX900 S2).

● Only slots 2&3 and slots 6&7 or slots 4&5 of a BX400 S1 system unit can be fitted with SX960 S1 storage blades. They provide the server blade in the adjacent slot to the left with additional disk space (see figure 3).

Figure 3: Fitting rules for the SX960 S1 storage blade within the BX400 S1 system unit

Storage Blade SX960

Server Blade

Option A: max. 2x SX960

Option B:

87654321Slot:

Page 24: PRIMERGY SX960 S1 Storage Blade - Operating Manualmanuals.ts.fujitsu.com/file/9903/sx960s1-om-en.pdf · The SX960 S1 storage blade can be fitted with a SAS RAID controller. Please

24 Operating Manual SX960 S1

Installation

© c

ogni

tas.

Ges

ells

chft

für T

echn

ik-D

okum

enta

tion

mbH

201

4 P

fad:

C:\P

rogr

amm

e\FC

T\tim

_app

\tim

_loc

al\w

ork\

PIC

HO

L\O

BJ_

DO

KU

-217

02-0

01.fm

● Only slots 7&8 and slots 15&16 of a BX900 S1/BX900 S2 system unit can be fitted with SX960 S1 storage blades. They provide the server blade in the adjacent slot to the left with additional disk space (see figure 4).

Figure 4: Fitting rules for the SX960 S1 storage blade within the BX900 S1/BX900 S2 system unit

Combinations of supported HDD/SSDs

The table below shows the possible combinations of the drive types that can be installed.

Y = supportedN = not supported

SATA BC SATA SAS SSDSATA Y Y N YBC SATA Y Y Y YSAS N Y Y YSSD Y Y Y Y

Storage Blade SX960 (max. 2x per system unit)

Server Blade

Slot: 76 85174321

1514 1613181211109Slot:

Page 25: PRIMERGY SX960 S1 Storage Blade - Operating Manualmanuals.ts.fujitsu.com/file/9903/sx960s1-om-en.pdf · The SX960 S1 storage blade can be fitted with a SAS RAID controller. Please

SX960 S1 Operating Manual 25

Installation

Removing the dummy blades

Any unused slots on the front of the system unit are fitted with appropriate dummy blades to comply with electromagnetic compatibility (EMC) regulations and to ensure sufficient cooling of the system components. The power supply unit slots on the back do not necessarily have to be populated.

To add a SX960 S1 storage blade, you first have to remove two dummy blades from the relevant slots.

Figure 5: Removing the dummy blades

Ê Push up the green release levers (see arrows) and pull the dummy blades out of their slots.

Page 26: PRIMERGY SX960 S1 Storage Blade - Operating Manualmanuals.ts.fujitsu.com/file/9903/sx960s1-om-en.pdf · The SX960 S1 storage blade can be fitted with a SAS RAID controller. Please

26 Operating Manual SX960 S1

Installation

© c

ogni

tas.

Ges

ells

chft

für T

echn

ik-D

okum

enta

tion

mbH

201

4 P

fad:

C:\P

rogr

amm

e\FC

T\tim

_app

\tim

_loc

al\w

ork\

PIC

HO

L\O

BJ_

DO

KU

-217

02-0

01.fm

V CAUTION!

Keep the dummy blade(s) for future use. If you remove a storage blade or a server blade and do not replace it with a new one, you must reinstall the dummy blade(s) due to cooling, to comply with EMC regulations, and to protect against fire.

Installing the dummy blades

Slide each dummy blade with the release lever down into the empty slot until it clicks into place.

Installing the storage blade

The SX960 S1 storage blade can be installed during operation and is recognized by the management blade. You must restart the related server blade to enable the storage blade to communicate with the server blade, see section "Putting the storage blade into operation" on page 34.

V CAUTION!

Follow the safety instructions and information in section "Electrostatic sensitive device label" on page 17.

I Make sure the storage blade is installed the correct way round. The control panel must be in the area at the top.

Page 27: PRIMERGY SX960 S1 Storage Blade - Operating Manualmanuals.ts.fujitsu.com/file/9903/sx960s1-om-en.pdf · The SX960 S1 storage blade can be fitted with a SAS RAID controller. Please

SX960 S1 Operating Manual 27

Installation

Unlocking and installing the storage blade

Figure 6: Unlocking the storage blade

Ê Undo the locking mechanism (1) of the release lever.

Ê Open the release lever (2).

Ê Push the storage blade as far as possible into the empty slot (3).

Page 28: PRIMERGY SX960 S1 Storage Blade - Operating Manualmanuals.ts.fujitsu.com/file/9903/sx960s1-om-en.pdf · The SX960 S1 storage blade can be fitted with a SAS RAID controller. Please

28 Operating Manual SX960 S1

Installation

© c

ogni

tas.

Ges

ells

chft

für T

echn

ik-D

okum

enta

tion

mbH

201

4 P

fad:

C:\P

rogr

amm

e\FC

T\tim

_app

\tim

_loc

al\w

ork\

PIC

HO

L\O

BJ_

DO

KU

-217

02-0

01.fm

Figure 7: Locking the storage blade

Ê Push the release lever up until it clicks into place under the locking lever (1).

Page 29: PRIMERGY SX960 S1 Storage Blade - Operating Manualmanuals.ts.fujitsu.com/file/9903/sx960s1-om-en.pdf · The SX960 S1 storage blade can be fitted with a SAS RAID controller. Please

SX960 S1 Operating Manual 29

Installation

Removing the storage blade

To remove the storage blade, you must first switch off the related server blade(s).

Ê Switch the server blade off: either using the On/Off button on the server blade or using the Web interface of the management blade (see the user interface description in the manual "ServerView Management Blade S1" for PRIMERGY BX400 Blade Server Systems respectively for PRIMERGY BX900 Blade Server Systems).

Ê Undo the locking mechanism of the release lever.

Ê Open the release lever.

Ê Pull the storage blade out of the slot.

V CAUTION!

If you have removed a storage blade and have not replaced it with a new one, you must install a dummy module in the empty slot.

Page 30: PRIMERGY SX960 S1 Storage Blade - Operating Manualmanuals.ts.fujitsu.com/file/9903/sx960s1-om-en.pdf · The SX960 S1 storage blade can be fitted with a SAS RAID controller. Please

30 Operating Manual SX960 S1

Installation

© c

ogni

tas.

Ges

ells

chft

für T

echn

ik-D

okum

enta

tion

mbH

201

4 P

fad:

C:\P

rogr

amm

e\FC

T\tim

_app

\tim

_loc

al\w

ork\

PIC

HO

L\O

BJ_

DO

KU

-217

02-0

01.fm

Page 31: PRIMERGY SX960 S1 Storage Blade - Operating Manualmanuals.ts.fujitsu.com/file/9903/sx960s1-om-en.pdf · The SX960 S1 storage blade can be fitted with a SAS RAID controller. Please

SX960 S1 Operating Manual 31

4 Operation

4.1 Control and display elements

Indicators on the storage blade

Figure 8: Indicators on the storage blade

1 ID card

You can pull out the ID card (see figure 8 above) as far as it will go and push it back in again.

The ID card contains various system information, such as product name, serial number and order number.

2 Power indicator (green)

– Lights up: the left server blade is switched on– Does not light: the left server blade is switched off

Page 32: PRIMERGY SX960 S1 Storage Blade - Operating Manualmanuals.ts.fujitsu.com/file/9903/sx960s1-om-en.pdf · The SX960 S1 storage blade can be fitted with a SAS RAID controller. Please

32 Operating Manual SX960 S1

Operation

© c

ogni

tas.

Ges

ells

chft

für T

echn

ik-D

okum

enta

tion

mbH

201

4 P

fad:

C:\P

rogr

amm

e\FC

T\tim

_app

\tim

_loc

al\w

ork\

PIC

HO

L\O

BJ_

DO

KU

-217

03-0

01.fm

3 ID indicator (blue)

Lights up blue when the system has been selected by pressing the ID button (4). To deactivate, press the ID button again.

The ID indicator can also be activated via the Management Blade Web interface and the ServerView Operations Manager and the iRMC Web interface and its status is reported to the ServerView Operations Manager and the iRMC.

4 ID button

When the ID button is pressed, the ID indicator (3) lights up.

Page 33: PRIMERGY SX960 S1 Storage Blade - Operating Manualmanuals.ts.fujitsu.com/file/9903/sx960s1-om-en.pdf · The SX960 S1 storage blade can be fitted with a SAS RAID controller. Please

SX960 S1 Operating Manual 33

Operation

Indicators on the HDD/SSD module

Figure 9: Indicators on the 2.5-inch HDD/SSD module

1 HDD/SSD BUSY (green)

– Lights up: HDD/SSD in active phase– Does not light: HDD/SSD inactive (drive inactive)

2 HDD/SSD FAULT (orange)(in conjunction with a RAID controller)

– Does not light: no HDD/SSD error– Lights up: HDD/SSD faulty or Rebuild stopped (drive defective,

needs replacing, a rebuild process was stopped or the HDD/SSD module is not correctly inserted)

– Slow flashing: HDD/SSD Rebuild (the data is being restored after changing a drive)

– Fast flashing: HDD/SSD Identify

a b

Page 34: PRIMERGY SX960 S1 Storage Blade - Operating Manualmanuals.ts.fujitsu.com/file/9903/sx960s1-om-en.pdf · The SX960 S1 storage blade can be fitted with a SAS RAID controller. Please

34 Operating Manual SX960 S1

Operation

© c

ogni

tas.

Ges

ells

chft

für T

echn

ik-D

okum

enta

tion

mbH

201

4 P

fad:

C:\P

rogr

amm

e\FC

T\tim

_app

\tim

_loc

al\w

ork\

PIC

HO

L\O

BJ_

DO

KU

-217

03-0

01.fm

4.2 Putting the storage blade into operation

The SX960 S1 storage blade can be installed during operation and is recognized by the management blade. You must restart the related server blade to enable the storage blade to communicate with the server blade.

Make sure that the storage blade is inserted correctly in the system unit (see section "Installing/removing a storage blade in/from the system unit" on page 23).

Ê There are two ways of restarting the server blade related to the storage blade:

– By pressing the On/Off button on the control panel of the server blade

– Via the Web interface of the management blade (see the user interface description in the manual "ServerView Management Blade S1" for PRIMERGY BX400 Blade Server Systems respectively for PRIMERGY BX900 Blade Server Systems).

As soon as the related server blades are in operation, the storage blade's power indicator lights up green. After that, configure the drives of the storage blade with the ServerView RAID Manager. You will find further information in the "PRIMERGY ServerView Suite RAID Management" manual.

Page 35: PRIMERGY SX960 S1 Storage Blade - Operating Manualmanuals.ts.fujitsu.com/file/9903/sx960s1-om-en.pdf · The SX960 S1 storage blade can be fitted with a SAS RAID controller. Please

SX960 S1 Operating Manual 35

5 Hot-plug componentsThis chapter describes how to replace or add hot-plug components in the SX960 S1 storage blade.

I The HDD/SSD modules are the only hot-plug components within the SX960 S1 storage blade.

5.1 Hot-plug drives

The drives which can be ordered for the storage blade SX960 S1 are supplied already mounted in an installation frame so that defective drives can be replaced and new drives can be added during operation. The drive and installation frame together make up the HDD/SSD module.

V CAUTION!

The drive must not be removed from the installation frame by anyone except a service technician.

Page 36: PRIMERGY SX960 S1 Storage Blade - Operating Manualmanuals.ts.fujitsu.com/file/9903/sx960s1-om-en.pdf · The SX960 S1 storage blade can be fitted with a SAS RAID controller. Please

36 Operating Manual SX960 S1

Hot-plug components

© c

ogni

tas.

Ges

ells

chft

für T

echn

ik-D

okum

enta

tion

mbH

201

4 P

fad:

C:\P

rogr

amm

e\FC

T\tim

_app

\tim

_loc

al\w

ork\

PIC

HO

L\O

BJ_

DO

KU

-217

04-0

01.fm

Figure 10: 2.5-inch HDD/SSD module and dummy module

Handling drives and HDD/SSD modules

Drives incorporated in the HDD/SSD modules are highly sensitive electromagnetic devices and must be handled with great care. Incorrect handling can cause partial or total failure of the drives. These failures can result in data errors and to a loss of data or to total corruption of the drive.

Observe the following rules to prevent such problems occurring:

● Only store and transport HDD/SSD modules within the limits stipulated in the specification.

1 Dummy module 2 Tabs for unlocking the dummy module3 HDD/SSD module (installation frame with drive installed)4 Indicators HDD/SSD Busy (green LED) and HDD/SSD Fault (orange

LED). For a description, see table on page 33 in section "Indicators on the HDD/SSD module".

5 Handle for locking and unlocking the HDD/SSD module6 Button for locking and unlocking the handle7 Pit for applying a sticker with the current drive name

Page 37: PRIMERGY SX960 S1 Storage Blade - Operating Manualmanuals.ts.fujitsu.com/file/9903/sx960s1-om-en.pdf · The SX960 S1 storage blade can be fitted with a SAS RAID controller. Please

SX960 S1 Operating Manual 37

Hot-plug components

● When transporting HDD/SSD modules (even over short distances), always use the original packaging (ESD label).

● Never expose HDD/SSD modules to a temperature shock. Avoid the formation of condensation inside and on the outside of the drive.

V CAUTION!

The HDD/SSD module must be acclimatized in its operating environment for an acclimatization time before it is started up for the first time.

● Always set the HDD/SSD module down carefully, with the large surface facing downwards to prevent it from tipping over.

5.2 Removing/installing the dummy module

Free slots are provided with dummy modules. Remove the dummy module before installing an additional HDD/SSD module.

Temperature difference (°C)(operating environment/

outside)

Minimum acclimatization time (hours)

5 310 515 720 825 930 10

Table 2: Acclimatization times for HDD/SSD modules

Page 38: PRIMERGY SX960 S1 Storage Blade - Operating Manualmanuals.ts.fujitsu.com/file/9903/sx960s1-om-en.pdf · The SX960 S1 storage blade can be fitted with a SAS RAID controller. Please

38 Operating Manual SX960 S1

Hot-plug components

© c

ogni

tas.

Ges

ells

chft

für T

echn

ik-D

okum

enta

tion

mbH

201

4 P

fad:

C:\P

rogr

amm

e\FC

T\tim

_app

\tim

_loc

al\w

ork\

PIC

HO

L\O

BJ_

DO

KU

-217

04-0

01.fm

Figure 11: Removing the dummy module

Ê Press both tabs on the dummy module together until the locking mechanism disengages (1).

Ê Pull the dummy module out of the slot (2).

To install a dummy module, follow the same procedure in reverse order.

V CAUTION!

Store the dummy module in a safe place. If you have removed an HDD/SSD module and do not install a new one in its place, put the dummy module back in its place for cooling, to comply with EMC regulations (regulations regarding electromagnetic compatibility), and for protection against fire. Ensure that the dummy module engages correctly in the slot.

Page 39: PRIMERGY SX960 S1 Storage Blade - Operating Manualmanuals.ts.fujitsu.com/file/9903/sx960s1-om-en.pdf · The SX960 S1 storage blade can be fitted with a SAS RAID controller. Please

SX960 S1 Operating Manual 39

Hot-plug components

5.3 Installing/removing the HDD/SSD module

Unlocking the HDD/SSD module

Figure 12: Unlocking the 2.5-inch HDD/SSD module

Ê Release the locking mechanism as follows:

1. Press the two green tabs of the locking lever together (1).

2. Pull the handle of the HDD/SSD module fully in the direction of the arrow (2). The HDD/SSD module is now unlocked.

Page 40: PRIMERGY SX960 S1 Storage Blade - Operating Manualmanuals.ts.fujitsu.com/file/9903/sx960s1-om-en.pdf · The SX960 S1 storage blade can be fitted with a SAS RAID controller. Please

40 Operating Manual SX960 S1

Hot-plug components

© c

ogni

tas.

Ges

ells

chft

für T

echn

ik-D

okum

enta

tion

mbH

201

4 P

fad:

C:\P

rogr

amm

e\FC

T\tim

_app

\tim

_loc

al\w

ork\

PIC

HO

L\O

BJ_

DO

KU

-217

04-0

01.fm

Installing the HDD/SSD module

Figure 13: Installing the HDD/SSD module

Ê Unlock the HDD/SSD module as described in section "Unlocking the HDD/SSD module" on page 39.

Ê Carefully push the HDD/SSD module into the empty mounting location (1) until it stops.

Ê Push the handle completely in the direction of the arrow (2) until the locking mechanism engages.

Removing the HDD/SSD module

V CAUTION!

Replace an HDD/SSD module only while the system is powered on. Replacing an HDD/SSD module while the system is off would impact the RAID configuration at the next power up.

Page 41: PRIMERGY SX960 S1 Storage Blade - Operating Manualmanuals.ts.fujitsu.com/file/9903/sx960s1-om-en.pdf · The SX960 S1 storage blade can be fitted with a SAS RAID controller. Please

SX960 S1 Operating Manual 41

Hot-plug components

If you want to remove an HDD/SSD module during operation, proceed as follows:

Ê If you want to remove an HDD/SSD module that is not defective, the drive must be first set to offline via the software (RAID controller configuration software).

Ê Unlock the HDD/SSD module as described in section "Unlocking the HDD/SSD module" on page 39.

Ê Pull the HDD/SSD module out a few centimeters.

Ê Wait for at least 60 seconds.

I This period is necessary for the RAID controller to recognize that an HDD/SSD module has been removed and for the drive to come to a stop.

Ê Pull the HDD/SSD module out completely.

Ê Install the new HDD/SSD module, as described in sections "Unlocking the HDD/SSD module" on page 39 and "Installing the HDD/SSD module" on page 40.

V CAUTION!

If you have removed an HDD/SSD module and do not install a new one in its place, put the dummy module back in its place for cooling, to comply with EMC regulations (regulations regarding electromagnetic compatibility), and for protection against fire. Ensure that the dummy module engages correctly in the slot.

Page 42: PRIMERGY SX960 S1 Storage Blade - Operating Manualmanuals.ts.fujitsu.com/file/9903/sx960s1-om-en.pdf · The SX960 S1 storage blade can be fitted with a SAS RAID controller. Please

42 Operating Manual SX960 S1

Hot-plug components

© c

ogni

tas.

Ges

ells

chft

für T

echn

ik-D

okum

enta

tion

mbH

201

4 P

fad:

C:\P

rogr

amm

e\FC

T\tim

_app

\tim

_loc

al\w

ork\

PIC

HO

L\O

BJ_

DO

KU

-217

04-0

01.fm

Page 43: PRIMERGY SX960 S1 Storage Blade - Operating Manualmanuals.ts.fujitsu.com/file/9903/sx960s1-om-en.pdf · The SX960 S1 storage blade can be fitted with a SAS RAID controller. Please

SX960 S1 Operating Manual 43

6 Optional: Installation / Replacement of BBU / FBU

Together with the controllers used with SX960 S1, a Battery Backup Unit (BBU) or a Flash Backup Unit (FBU) optionally can be installed (see following table).

Only for the Japanese market:

Product SX960 S1 BBU Holder in SX960

iBBU/FBU Cable iBBU/FBU RAID Controller

S26361-K1382-V200 / S26361-K1382-V901

S26361-K1382-V202 / S26361-K1382-V902

BBU holder for iBBU07 fix mounted

LTG iBBU 160T26139-Y3987-V338006680

IBBU07 LI-IONLSZ:L5-25034-20S26361-F3257-E116

MEGARAID 2108 D2616 (Cougar II)S26361-D2616-A22-1-R79138016965S26361-F3554-E/L512

S26361-K1382-V303 / S26361-K1382-V903

Common iBBU07/iBBU08 holderC26361-K644-C942

LTG iBBU 550T26139-Y3987-V238004612

LTG iBBU 160T26139-Y3987-V338006680

IBBU08 LI-IONLSZ:L5-25343-08S26361-F3257-E216

FBU02FBU holderC26361-K644-C970

CBL FBU02 170T26139-Y4032-V338019754

FBU02LSZ:L3-0087-00S26361-F3669-E125

MEGARAID 2208 D3116 (Cougar III)S26361-D3116-C20038037383S26361-F3669-E/L4

SX960 S1 対応 BBU 対応 FBU

型名 型名 参照 型名

PY-S96AD1PYBBBR05A

BBU07 の手順をご確認く ださい 搭載できませんPYB-BBR04A

PY-S96AD2PYBBBR03A BBU08 の手順をご確認く ださい PYBFBR02

PY-BBR01A BBU07 の手順をご確認く ださい

(55cm のケーブルをご使用ください )PY-FBR01

Page 44: PRIMERGY SX960 S1 Storage Blade - Operating Manualmanuals.ts.fujitsu.com/file/9903/sx960s1-om-en.pdf · The SX960 S1 storage blade can be fitted with a SAS RAID controller. Please

44 Operating Manual SX960 S1

Optional: Installation / Replacement of BBU / FBU

© c

ogni

tas.

Ges

ells

chft

für T

echn

ik-D

okum

enta

tion

mbH

201

4 P

fad:

C:\P

rogr

amm

e\FC

T\tim

_app

\tim

_loc

al\w

ork\

PIC

HO

L\O

BJ_

DO

KU

-217

05-0

01.fm

6.1 Installing the BBU07/08

6.1.1 Preparations

Ê Remove the storage blade as described in section "Installing/removing a storage blade in/from the system unit" on page 29.

Figure 14: Opening the storage blade

Ê Press down the touch point (1) and push the housing cover in the direction of the arrow as far as it will go (2).

Ê Lift off the housing cover.

Page 45: PRIMERGY SX960 S1 Storage Blade - Operating Manualmanuals.ts.fujitsu.com/file/9903/sx960s1-om-en.pdf · The SX960 S1 storage blade can be fitted with a SAS RAID controller. Please

SX960 S1 Operating Manual 45

Optional: Installation / Replacement of BBU / FBU

Removing the controller

Figure 15: Removing the controller

Ê Remove both SAS cables from the controller (1 & 2).

I Do not bend SAS cables!

Ê Remove the screw (3).

Ê Pull the controller out of the contact strip of the interposer board (4).

Installation will be done in reverse order.

Page 46: PRIMERGY SX960 S1 Storage Blade - Operating Manualmanuals.ts.fujitsu.com/file/9903/sx960s1-om-en.pdf · The SX960 S1 storage blade can be fitted with a SAS RAID controller. Please

46 Operating Manual SX960 S1

Optional: Installation / Replacement of BBU / FBU

© c

ogni

tas.

Ges

ells

chft

für T

echn

ik-D

okum

enta

tion

mbH

201

4 P

fad:

C:\P

rogr

amm

e\FC

T\tim

_app

\tim

_loc

al\w

ork\

PIC

HO

L\O

BJ_

DO

KU

-217

05-0

01.fm

Removing the interposer board

Figure 16: Removing the interposer board

Ê Remove the power cable (1).

Ê Remove the cable from the control panel (2).

Ê Lift up both metal clips (3) as far as they will go.

Ê Remove the interposer board (4).

Installation will be done in reverse order.

Page 47: PRIMERGY SX960 S1 Storage Blade - Operating Manualmanuals.ts.fujitsu.com/file/9903/sx960s1-om-en.pdf · The SX960 S1 storage blade can be fitted with a SAS RAID controller. Please

SX960 S1 Operating Manual 47

Optional: Installation / Replacement of BBU / FBU

Preparing the BBU07

Figure 17: Parts of the BBU07 kit

Pos. Description1 BBU (battery pack) with electronic parts underneath2 BBU holder3 Cable connecting BBU to controller

Page 48: PRIMERGY SX960 S1 Storage Blade - Operating Manualmanuals.ts.fujitsu.com/file/9903/sx960s1-om-en.pdf · The SX960 S1 storage blade can be fitted with a SAS RAID controller. Please

48 Operating Manual SX960 S1

Optional: Installation / Replacement of BBU / FBU

© c

ogni

tas.

Ges

ells

chft

für T

echn

ik-D

okum

enta

tion

mbH

201

4 P

fad:

C:\P

rogr

amm

e\FC

T\tim

_app

\tim

_loc

al\w

ork\

PIC

HO

L\O

BJ_

DO

KU

-217

05-0

01.fm

Connecting the BBU cable to the BBU07

Figure 18: Connecting the BBU cable

Ê Plug the BBU cable in the connector on the BBU board (see pos. 1 in figure above).

I The plug of the BBU cable has a number printed on the back. Make sure this side of the plug faces down, i.e. is not visible.

Ê Check whether the cable of the battery is connected to the BBU board (see pos. 2 in figure above).

Inserting the BBU07 into the holder of BBU08

Ê Proceed as described in section "Inserting the BBU08 into the holder" on page 51.

Page 49: PRIMERGY SX960 S1 Storage Blade - Operating Manualmanuals.ts.fujitsu.com/file/9903/sx960s1-om-en.pdf · The SX960 S1 storage blade can be fitted with a SAS RAID controller. Please

SX960 S1 Operating Manual 49

Optional: Installation / Replacement of BBU / FBU

Preparing the BBU08

The following figure shows all parts of the BBU08 kit:

Figure 19: Parts of the BBU08 kit

1 Cable from BBU (battery pack) to controller2 Holder for BBU (battery pack) with 3 keyhole slots for mounting purposes3 BBU (battery pack)

Page 50: PRIMERGY SX960 S1 Storage Blade - Operating Manualmanuals.ts.fujitsu.com/file/9903/sx960s1-om-en.pdf · The SX960 S1 storage blade can be fitted with a SAS RAID controller. Please

50 Operating Manual SX960 S1

Optional: Installation / Replacement of BBU / FBU

© c

ogni

tas.

Ges

ells

chft

für T

echn

ik-D

okum

enta

tion

mbH

201

4 P

fad:

C:\P

rogr

amm

e\FC

T\tim

_app

\tim

_loc

al\w

ork\

PIC

HO

L\O

BJ_

DO

KU

-217

05-0

01.fm

Connecting the BBU cable to the BBU08

Figure 20: Connecting the BBU cable

Ê Plug the BBU cable in the connector on the BBU08 (see figure).

I The plug of the BBU cable is coded, i.e., it can only be plugged in correctly.

Page 51: PRIMERGY SX960 S1 Storage Blade - Operating Manualmanuals.ts.fujitsu.com/file/9903/sx960s1-om-en.pdf · The SX960 S1 storage blade can be fitted with a SAS RAID controller. Please

SX960 S1 Operating Manual 51

Optional: Installation / Replacement of BBU / FBU

Inserting the BBU08 into the holder

Figure 21: Installing the BBU08 in the BBU08 holder (A)

Ê At a slight angle, fit the BBU08 under the upper retaining bracket (see frame) of the BBU holder as shown.

Ê Push on the BBU08 (see arrow in figure above) until it locks in place.

Figure 22: Installing the BBU08 in the BBU08 holder (B)

Ê Ensure that the BBU08 is properly seated in the BBU holder as shown.

Page 52: PRIMERGY SX960 S1 Storage Blade - Operating Manualmanuals.ts.fujitsu.com/file/9903/sx960s1-om-en.pdf · The SX960 S1 storage blade can be fitted with a SAS RAID controller. Please

52 Operating Manual SX960 S1

Optional: Installation / Replacement of BBU / FBU

© c

ogni

tas.

Ges

ells

chft

für T

echn

ik-D

okum

enta

tion

mbH

201

4 P

fad:

C:\P

rogr

amm

e\FC

T\tim

_app

\tim

_loc

al\w

ork\

PIC

HO

L\O

BJ_

DO

KU

-217

05-0

01.fm

6.1.2 Mounting the BBU07

I The BBU07 can be installed within two kinds of holder:

– BBU 07 holder (see figure 17 on page 47)

– BBU 08 holder (see figure 19 on page 49)

Figure 23: Installation location of BBU07

Ê The 3 shoulder screw caps (pos. #1 - #3) ensure that the BBU holder fits tightly.

Ê The eye (pos. #4) is needed to let the hook of the holder click into place (#4).

Page 53: PRIMERGY SX960 S1 Storage Blade - Operating Manualmanuals.ts.fujitsu.com/file/9903/sx960s1-om-en.pdf · The SX960 S1 storage blade can be fitted with a SAS RAID controller. Please

SX960 S1 Operating Manual 53

Optional: Installation / Replacement of BBU / FBU

Figure 24: Placing the BBU08 holder onto the shoulder screw caps

Ê Turn the BBU07 by 180° and place it with its keyhole slots on the 3 shoulder screw caps (see arrows #1 - #3)).

Figure 25: Locking the BBU07 into place

Ê Push the BBU07 in the direction of the arrow until it snaps into place.

Page 54: PRIMERGY SX960 S1 Storage Blade - Operating Manualmanuals.ts.fujitsu.com/file/9903/sx960s1-om-en.pdf · The SX960 S1 storage blade can be fitted with a SAS RAID controller. Please

54 Operating Manual SX960 S1

Optional: Installation / Replacement of BBU / FBU

© c

ogni

tas.

Ges

ells

chft

für T

echn

ik-D

okum

enta

tion

mbH

201

4 P

fad:

C:\P

rogr

amm

e\FC

T\tim

_app

\tim

_loc

al\w

ork\

PIC

HO

L\O

BJ_

DO

KU

-217

05-0

01.fm

Reinstalling the interposer board

Figure 26: Reinstalling the interposer board

Ê Lift up both metal clips (1).

Ê Shift the interposer board into the marked openings (see circles) of the metal cage.

Ê Press on the metal clips to fix the interposer board (3).

Reinstalling the controller

Ê Reinstall the controller. Follow the instructions on page 45 in reverse order.

Page 55: PRIMERGY SX960 S1 Storage Blade - Operating Manualmanuals.ts.fujitsu.com/file/9903/sx960s1-om-en.pdf · The SX960 S1 storage blade can be fitted with a SAS RAID controller. Please

SX960 S1 Operating Manual 55

Optional: Installation / Replacement of BBU / FBU

Connecting the BBU cable to the controller

Figure 27: Connecting the BBU cable to the controller

Ê Connect the BBU cable to the BBU connector of the controller (see oval).

Page 56: PRIMERGY SX960 S1 Storage Blade - Operating Manualmanuals.ts.fujitsu.com/file/9903/sx960s1-om-en.pdf · The SX960 S1 storage blade can be fitted with a SAS RAID controller. Please

56 Operating Manual SX960 S1

Optional: Installation / Replacement of BBU / FBU

© c

ogni

tas.

Ges

ells

chft

für T

echn

ik-D

okum

enta

tion

mbH

201

4 P

fad:

C:\P

rogr

amm

e\FC

T\tim

_app

\tim

_loc

al\w

ork\

PIC

HO

L\O

BJ_

DO

KU

-217

05-0

01.fm

Closing the storage blade

Figure 28: Closing the storage blade

Ê Position the housing cover on the housing approx. 1-2 cm from the frame, so that it is level on both sides.

Ê Push the housing cover in the direction of the arrow until it clicks into place.

Insert the storage blade in the system unit as described in section "Installing/removing a storage blade in/from the system unit" on page 27.

Page 57: PRIMERGY SX960 S1 Storage Blade - Operating Manualmanuals.ts.fujitsu.com/file/9903/sx960s1-om-en.pdf · The SX960 S1 storage blade can be fitted with a SAS RAID controller. Please

SX960 S1 Operating Manual 57

Optional: Installation / Replacement of BBU / FBU

6.1.3 Mounting the BBU08

The BBU holder is installed below the interposer board:

Figure 29: Installation location of BBU08

Ê The 3 shoulder screw caps (pos. #1 - #3) ensure that the BBU holder fits tightly.

Ê The eye (pos. #4) is needed to let the hook of the holder click into place (#4).

Page 58: PRIMERGY SX960 S1 Storage Blade - Operating Manualmanuals.ts.fujitsu.com/file/9903/sx960s1-om-en.pdf · The SX960 S1 storage blade can be fitted with a SAS RAID controller. Please

58 Operating Manual SX960 S1

Optional: Installation / Replacement of BBU / FBU

© c

ogni

tas.

Ges

ells

chft

für T

echn

ik-D

okum

enta

tion

mbH

201

4 P

fad:

C:\P

rogr

amm

e\FC

T\tim

_app

\tim

_loc

al\w

ork\

PIC

HO

L\O

BJ_

DO

KU

-217

05-0

01.fm

Figure 30: Placing the BBU holder onto the shoulder screw caps

Ê Turn the BBU08 by 180° and place it with its keyhole slots on the 3 shoulder screw caps (see arrows #1 - #3)).

Figure 31: Locking the BBU08 into place

Ê Push the BBU08 in the direction of the arrow until it snaps into place.

Page 59: PRIMERGY SX960 S1 Storage Blade - Operating Manualmanuals.ts.fujitsu.com/file/9903/sx960s1-om-en.pdf · The SX960 S1 storage blade can be fitted with a SAS RAID controller. Please

SX960 S1 Operating Manual 59

Optional: Installation / Replacement of BBU / FBU

Reinstalling the interposer board

Ê Proceed as described in section "Reinstalling the interposer board" on page 54.

Reinstalling the controller

Ê Reinstall the controller. Follow the instructions on page 45 in reverse order.

Connecting the BBU08 cable to the controller

Figure 32: Connecting the BBU08 cable to the controller

Ê Connect the BBU08 cable to the BBU connector of the controller (see oval).

Closing the storage blade

Ê Proceed as described in section "Closing the storage blade" on page 56.

Insert the storage blade in the system unit as described in section "Installing/removing a storage blade in/from the system unit" on page 27.

Page 60: PRIMERGY SX960 S1 Storage Blade - Operating Manualmanuals.ts.fujitsu.com/file/9903/sx960s1-om-en.pdf · The SX960 S1 storage blade can be fitted with a SAS RAID controller. Please

60 Operating Manual SX960 S1

Optional: Installation / Replacement of BBU / FBU

© c

ogni

tas.

Ges

ells

chft

für T

echn

ik-D

okum

enta

tion

mbH

201

4 P

fad:

C:\P

rogr

amm

e\FC

T\tim

_app

\tim

_loc

al\w

ork\

PIC

HO

L\O

BJ_

DO

KU

-217

05-0

01.fm

6.2 Installing the FBU

6.2.1 Preparations

Ê Remove the storage blade as described in section "Installing/removing a storage blade in/from the system unit" on page 29.

Ê Proceed as described in section Preparations.

Removing the controller

Ê Proceed as described in section "Removing the controller" on page 45.

Removing the interposer board

Ê Proceed as described in section "Removing the interposer board" on page 46.

Page 61: PRIMERGY SX960 S1 Storage Blade - Operating Manualmanuals.ts.fujitsu.com/file/9903/sx960s1-om-en.pdf · The SX960 S1 storage blade can be fitted with a SAS RAID controller. Please

SX960 S1 Operating Manual 61

Optional: Installation / Replacement of BBU / FBU

Preparing the FBU

The following figure shows all parts of the FBU kit:

Figure 33: All parts of the FBU kit

1 Holder for battery pack with 3 keyhole slots for mounting purposes2 Battery pack 3 Adapter cable for connection with battery pack and controller

Page 62: PRIMERGY SX960 S1 Storage Blade - Operating Manualmanuals.ts.fujitsu.com/file/9903/sx960s1-om-en.pdf · The SX960 S1 storage blade can be fitted with a SAS RAID controller. Please

62 Operating Manual SX960 S1

Optional: Installation / Replacement of BBU / FBU

© c

ogni

tas.

Ges

ells

chft

für T

echn

ik-D

okum

enta

tion

mbH

201

4 P

fad:

C:\P

rogr

amm

e\FC

T\tim

_app

\tim

_loc

al\w

ork\

PIC

HO

L\O

BJ_

DO

KU

-217

05-0

01.fm

Figure 34: Installing the FBU in the FBU holder (A)

Ê At a slight angle, fit the FBU (A3C40137317) under both retaining brackets of the FBU holder (C26361-K644-C970) as shown.

Ê Push in the FBU until it locks in place.

Figure 35: Installing the FBU in the FBU holder (B)

Ê Ensure that the FBU is properly seated in the FBU holder as shown.

Page 63: PRIMERGY SX960 S1 Storage Blade - Operating Manualmanuals.ts.fujitsu.com/file/9903/sx960s1-om-en.pdf · The SX960 S1 storage blade can be fitted with a SAS RAID controller. Please

SX960 S1 Operating Manual 63

Optional: Installation / Replacement of BBU / FBU

Figure 36: Connecting the FBU adapter cable to the FBU

Ê Connect the cable end of the FBU module to the FBU adapter cable (T26139-Y4032-V1) as shown.

Page 64: PRIMERGY SX960 S1 Storage Blade - Operating Manualmanuals.ts.fujitsu.com/file/9903/sx960s1-om-en.pdf · The SX960 S1 storage blade can be fitted with a SAS RAID controller. Please

64 Operating Manual SX960 S1

Optional: Installation / Replacement of BBU / FBU

© c

ogni

tas.

Ges

ells

chft

für T

echn

ik-D

okum

enta

tion

mbH

201

4 P

fad:

C:\P

rogr

amm

e\FC

T\tim

_app

\tim

_loc

al\w

ork\

PIC

HO

L\O

BJ_

DO

KU

-217

05-0

01.fm

6.2.2 Mounting the FBU

The FBU holder is installed below the interposer board:

Figure 37: Installation location of FBU08

Ê The 3 shoulder screw caps (pos. #1 - #3) ensure that the FBU08 holder fits tightly.

Ê The eye (pos. #4) is needed to let the hook of the holder click into place (#4).

Page 65: PRIMERGY SX960 S1 Storage Blade - Operating Manualmanuals.ts.fujitsu.com/file/9903/sx960s1-om-en.pdf · The SX960 S1 storage blade can be fitted with a SAS RAID controller. Please

SX960 S1 Operating Manual 65

Optional: Installation / Replacement of BBU / FBU

Figure 38: Placing the FBU holder onto the shoulder screw caps

Ê Turn the FBU by 180° and place it with its keyhole slots on the 3 shoulder screw caps (see arrows #1 - #3)).

Figure 39: Locking the FBU into place

Ê Push the FBU in the direction of the arrow until it snaps into place.

Page 66: PRIMERGY SX960 S1 Storage Blade - Operating Manualmanuals.ts.fujitsu.com/file/9903/sx960s1-om-en.pdf · The SX960 S1 storage blade can be fitted with a SAS RAID controller. Please

66 Operating Manual SX960 S1

Optional: Installation / Replacement of BBU / FBU

© c

ogni

tas.

Ges

ells

chft

für T

echn

ik-D

okum

enta

tion

mbH

201

4 P

fad:

C:\P

rogr

amm

e\FC

T\tim

_app

\tim

_loc

al\w

ork\

PIC

HO

L\O

BJ_

DO

KU

-217

05-0

01.fm

Reinstalling the interposer board

Ê Proceed as described in section "Reinstalling the interposer board" on page 54.

Reinstalling the controller

Ê Reinstall the controller. Follow the instructions on page 45 in reverse order.

Connecting the FBU cable to the controller

Figure 40: Connecting the FBU cable to the controller

Ê Connect the FBU cable to the FBU connector on the controller (see oval).

Closing the storage blade

Ê Proceed as described in section "Closing the storage blade" on page 56 of chapter Installing the BBU07/08.

Insert the storage blade in the system unit as described in section "Installing/removing a storage blade in/from the system unit" on page 27.

Page 67: PRIMERGY SX960 S1 Storage Blade - Operating Manualmanuals.ts.fujitsu.com/file/9903/sx960s1-om-en.pdf · The SX960 S1 storage blade can be fitted with a SAS RAID controller. Please

SX960 S1 Operating Manual 67

Optional: Installation / Replacement of BBU / FBU

6.3 Replacing the BBU07/08

6.3.1 Removing the BBU07/08

Ê Remove the storage blade from the system unit as described in page 29.

Ê Open the storage blade as described on page 44.

Figure 41: Removing the BBU07/08

Ê Remove the BBU cable from the BBU connector of the controller (1).

Ê Lift up the locking hook (2).

Ê Shift the BBU in the direction of the arrow and out of the housing (3).

Page 68: PRIMERGY SX960 S1 Storage Blade - Operating Manualmanuals.ts.fujitsu.com/file/9903/sx960s1-om-en.pdf · The SX960 S1 storage blade can be fitted with a SAS RAID controller. Please

68 Operating Manual SX960 S1

Optional: Installation / Replacement of BBU / FBU

© c

ogni

tas.

Ges

ells

chft

für T

echn

ik-D

okum

enta

tion

mbH

201

4 P

fad:

C:\P

rogr

amm

e\FC

T\tim

_app

\tim

_loc

al\w

ork\

PIC

HO

L\O

BJ_

DO

KU

-217

05-0

01.fm

Removing the BBU from its holder

Figure 42: Installing the BBU in the BBU holder (A)

Ê Press against the lower retaining bracket (see frame) to open the holder wide enough for removing the BBU.

Ê Lift the BBU out of the holder (see arrow).

Figure 43: Disconnecting the BBU cable

Ê Unplug the cable from the connector of the BBU (see arrow).

Page 69: PRIMERGY SX960 S1 Storage Blade - Operating Manualmanuals.ts.fujitsu.com/file/9903/sx960s1-om-en.pdf · The SX960 S1 storage blade can be fitted with a SAS RAID controller. Please

SX960 S1 Operating Manual 69

Optional: Installation / Replacement of BBU / FBU

6.3.2 Installing the BBU07/08

Ê Plug the BBU cable into the connector on the new BBU07 (see figure 17 on page 48) respectively on the new BBU08 (see figure 20 on page 50).

I The plug of the BBU cable is coded, i.e., it can only be plugged in correctly.

Ê Insert the new BBU07/08 into its holder (see "Inserting the BBU08 into the holder" on page 51).

Ê Install the new BBU07/08 into the housing (see "Mounting the BBU08" on page 57).

Ê Close the storage blade as described on page 56.

Insert the storage blade in the system unit as described in section "Installing/removing a storage blade in/from the system unit" on page 27.

Page 70: PRIMERGY SX960 S1 Storage Blade - Operating Manualmanuals.ts.fujitsu.com/file/9903/sx960s1-om-en.pdf · The SX960 S1 storage blade can be fitted with a SAS RAID controller. Please

70 Operating Manual SX960 S1

Optional: Installation / Replacement of BBU / FBU

© c

ogni

tas.

Ges

ells

chft

für T

echn

ik-D

okum

enta

tion

mbH

201

4 P

fad:

C:\P

rogr

amm

e\FC

T\tim

_app

\tim

_loc

al\w

ork\

PIC

HO

L\O

BJ_

DO

KU

-217

05-0

01.fm

6.4 Replacing the FBU

6.4.1 Removing the FBU

Ê Remove the storage blade from the system unit as described on page 29.

Ê Open the storage blade as described on page 44.

Figure 44: Removing the FBU

Ê Remove the FBU cable from the FBU adapter cable (1).

Ê Lift up the locking hook (2).

Ê Shift the FBU in the direction of the arrow and out of the housing (3).

Page 71: PRIMERGY SX960 S1 Storage Blade - Operating Manualmanuals.ts.fujitsu.com/file/9903/sx960s1-om-en.pdf · The SX960 S1 storage blade can be fitted with a SAS RAID controller. Please

SX960 S1 Operating Manual 71

Optional: Installation / Replacement of BBU / FBU

Figure 45: Removing the FBU from the FBU holder

Ê At a slight angle, slide the FBU from under the retaining brackets of the FBU holder and remove it.

Page 72: PRIMERGY SX960 S1 Storage Blade - Operating Manualmanuals.ts.fujitsu.com/file/9903/sx960s1-om-en.pdf · The SX960 S1 storage blade can be fitted with a SAS RAID controller. Please

72 Operating Manual SX960 S1

Optional: Installation / Replacement of BBU / FBU

© c

ogni

tas.

Ges

ells

chft

für T

echn

ik-D

okum

enta

tion

mbH

201

4 P

fad:

C:\P

rogr

amm

e\FC

T\tim

_app

\tim

_loc

al\w

ork\

PIC

HO

L\O

BJ_

DO

KU

-217

05-0

01.fm

6.4.2 Installing the FBU

Ê Insert the new FBU into its holder (see "Preparing the FBU" on page 61).

Figure 46: Inserting the new FBU into its holder

Ê Connect the FBU cable to the adapter cable (1).

Ê Install the new FBU into the housing (see "Mounting the FBU" on page 64).

Ê Close the storage blade as described on page 56.

Insert the storage blade in the system unit as described in section "Installing/removing a storage blade in/from the system unit" on page 27.

Page 73: PRIMERGY SX960 S1 Storage Blade - Operating Manualmanuals.ts.fujitsu.com/file/9903/sx960s1-om-en.pdf · The SX960 S1 storage blade can be fitted with a SAS RAID controller. Please

SX960 S1 Operating Manual 73

7 Troubleshooting and tipsV CAUTION!

Follow the safety instructions in chapter "Important notes" on page 15.

If the power-on indicator of the storage blade (see figure 8 on page 31) remains dark after you have switched on the related server blade, follow these instructions:

All information on troubleshooting faults that may occur when operating server blades in the system unit are described in the operating manual for the corresponding system unit.

If a fault occurs, try to correct it as described:

– in the chapter "Troubleshooting and tips" in the operating manual for your system unit,

– in the chapters for the installed components,– in the documentation for the connected devices,– in the help systems of the individual programs used.

If you do not manage to correct the problem, proceed as follows:

Ê Make a note of the steps you have taken and the situation in which the fault occurred. Also make a note of the error messages displayed.

Ê Switch off the defective server blade or the system.

Ê Contact customer service.

7.1 Drives reported as "dead" when starting system

RAID controller configuration incorrect

Ê Check and correct the settings for the drives using the RAID controller utility.

Further information is provided in the manual for the RAID controller.

Page 74: PRIMERGY SX960 S1 Storage Blade - Operating Manualmanuals.ts.fujitsu.com/file/9903/sx960s1-om-en.pdf · The SX960 S1 storage blade can be fitted with a SAS RAID controller. Please

74 Operating Manual SX960 S1

Troubleshooting and tips

© c

ogni

tas.

Ges

ells

chft

für T

echn

ik-D

okum

enta

tion

mbH

201

4 P

fad:

C:\P

rogr

amm

e\FC

T\tim

_app

\tim

_loc

al\w

ork\

PIC

HO

L\O

BJ_

DO

KU

-217

06-0

01.fm

7.2 Added drive reported as defective

RAID controller is not configured for this drive

The drive was probably installed when the system was switched off.

Ê Reconfigure the RAID controller for the drive using the corresponding utility. Information is provided in the documentation for the RAID controller.

or

Ê Remove and reinstall the drive while the system is switched ON.

If the drive continues to be shown as defective, then replace it.