primergy bx600 10gbe lan i/o module (pcie) -...

120
Reference Guide PRIMERGY BX600 10GbE LAN I/O Module (PCIe) Microsoft Windows Server 2008 iSCSI Initiator SM-CLP Command Reference Guide (v1.0.748.1282) English

Upload: lytram

Post on 12-Feb-2019

222 views

Category:

Documents


0 download

TRANSCRIPT

Page 1: PRIMERGY BX600 10GbE LAN I/O Module (PCIe) - Fujitsumanuals.ts.fujitsu.com/file/8372/bx-10gbe-sm-clp-ref-win08.pdf · PRIMERGY BX600 10GbE LAN I/O Module ... Microsoft Windows Server

Reference Guide

PRIMERGY BX600 10GbE LAN I/O Module (PCIe) Microsoft Windows Server 2008

iSCSI Initiator SM-CLP Command Reference Guide (v1.0.748.1282)

English

Page 2: PRIMERGY BX600 10GbE LAN I/O Module (PCIe) - Fujitsumanuals.ts.fujitsu.com/file/8372/bx-10gbe-sm-clp-ref-win08.pdf · PRIMERGY BX600 10GbE LAN I/O Module ... Microsoft Windows Server

Edition November 2008

PRIMERGY BX600 10GbE LAN I/O Module (PCIe) Microsoft Windows Server 2008

iSCSI Initiator SM-CLP Command Reference Guide (v1.0.748.1282)

Page 3: PRIMERGY BX600 10GbE LAN I/O Module (PCIe) - Fujitsumanuals.ts.fujitsu.com/file/8372/bx-10gbe-sm-clp-ref-win08.pdf · PRIMERGY BX600 10GbE LAN I/O Module ... Microsoft Windows Server

Comments… Suggestions… Corrections…The User Documentation Department would like to know your opinion on this manual. Your feedback helps us to optimize our documentation to suit your individual needs.

Feel free to send us your comments by e-mail to: [email protected]

Certified documentation according to DIN EN ISO 9001:2000To ensure a consistently high quality standard and user-friendliness, this documentation was created to meet the regulations of a quality management system which complies with the requirements of the standard DIN EN ISO 9001:2000.

cognitas. Gesellschaft für Technik-Dokumentation mbH www.cognitas.de

Copyright and Trademarks

This manual is printed on paper treated with chlorine-free bleach.

Copyright © Fujitsu Siemens Computers GmbH 2008.

All rights reserved. Delivery subject to availability; right of technical modifications reserved.

All hardware and software names used are trademarks of their respective manufacturers.

Page 4: PRIMERGY BX600 10GbE LAN I/O Module (PCIe) - Fujitsumanuals.ts.fujitsu.com/file/8372/bx-10gbe-sm-clp-ref-win08.pdf · PRIMERGY BX600 10GbE LAN I/O Module ... Microsoft Windows Server

BladeEngine iSCSI Initiator SM-CLP Command Reference Guide Version: v1.0.748.1282

Date: November 25, 2008

Watermark:

Table of Contents 1. Revision History 2. Introduction

2.1. Glossary 2.2. Document Convention 2.3. Hardware and Software Dependencies

3. Using the BladeEngine SM-CLP Client 3.1. Connecting to the BladeEngine server using SM-CLP Client 3.2. SM-CLP Client Command Line Options 3.3. Accessing Help

4. Basic Commands 4.1. common options 4.2. output arguments 4.3. cd 4.4. show 4.5. set 4.6. OEMSESaveConfig 4.7. help 4.8. version 4.9. exit

5. OEMSE Commands 5.1. Group Maps 5.2. OEMSEUpgradeFlashROM 5.3. OEMSERefreshEventLog 5.4. OEMSEClearEventLog 5.5. OEMSEConfigureIPAddress 5.6. OEMSEConfigureDHCP 5.7. OEMSERefreshNICConfig 5.8. OEMSEAddRouteTableEntry 5.9. OEMSEDeleteRouteTableEntry 5.10. OEMSERefreshRouteTableEntry 5.11. OEMSEAddARPTableEntry 5.12. OEMSEDeleteARPTableEntry 5.13. OEMSERefreshARPTableEntry 5.14. OEMSEPing 5.15. OEMSEDiscoveryiSNSThruDHCP 5.16. OEMSEAddiSNSServer 5.17. OEMSEDeleteiSNSServer 5.18. OEMSEEraseConfiguration 5.19. OEMSETestUnitReady 5.20. OEMSEStdInquiry 5.21. OEMSEReadCapacity 5.22. OEMSESCSIRead

Page 5: PRIMERGY BX600 10GbE LAN I/O Module (PCIe) - Fujitsumanuals.ts.fujitsu.com/file/8372/bx-10gbe-sm-clp-ref-win08.pdf · PRIMERGY BX600 10GbE LAN I/O Module ... Microsoft Windows Server

5.23. OEMSESCSIWrite 5.24. OEMSELogin 5.25. OEMSELogout 5.26. OEMSEReScanLUNS 5.27. OEMSEDiscoverTargets 5.28. OEMSEAddSendTargetPortal 5.29. OEMSEDeleteSendTargetPortal 5.30. OEMSERefreshAvailableTargets 5.31. OEMSEAddTarget 5.32. OEMSEDeleteTarget

6. Appendix 6.1. MILI_Groups

6.1.1. ROOT 6.1.2. BladeEngine 6.1.3. EventLog 6.1.4. EventLogEntry 6.1.5. NICPhysicalHBA 6.1.6. PCI 6.1.7. Driver 6.1.8. LogicalHBA 6.1.9. QoS 6.1.10. iSCSIPhysicalHBA 6.1.11. Driver 6.1.12. Network 6.1.13. DHCP 6.1.14. TCPIPConfiguration 6.1.15. NICConfiguration 6.1.16. RouteTable 6.1.17. RouteTableEntry 6.1.18. ARPTable 6.1.19. ARPTableEntry 6.1.20. PCI 6.1.21. iSNS 6.1.22. iSNSServer 6.1.23. LogicalHBA 6.1.24. InitiatoriSCSIName 6.1.25. InitiatorDefaultLoginOptions 6.1.26. InitiatorLoginOptions 6.1.27. Authentication 6.1.28. QoS 6.1.29. iSCSIStatistics 6.1.30. Target 6.1.31. TargetPortal 6.1.32. TargetLoginOptions 6.1.33. Authentication 6.1.34. Session 6.1.35. SessionNegotiatedLoginOptions 6.1.36. iSCSISessionStatistics 6.1.37. Connection 6.1.38. ConnectionNegotiatedLoginOptions 6.1.39. LUN 6.1.40. Discovery 6.1.41. SendTargetPortal 6.1.42. SendTargetPortalLoginOptions 6.1.43. Authentication

6.2. MILI_Properties 6.2.1. MILIServiceVersion 6.2.2. MILIHierarchyVersion 6.2.3. Manufacturer 6.2.4. ModelNumber 6.2.5. Description 6.2.6. SerialNumber 6.2.7. ActiveFirmwareVersion

Page 6: PRIMERGY BX600 10GbE LAN I/O Module (PCIe) - Fujitsumanuals.ts.fujitsu.com/file/8372/bx-10gbe-sm-clp-ref-win08.pdf · PRIMERGY BX600 10GbE LAN I/O Module ... Microsoft Windows Server

6.2.8. FirmwareVersionOnFlash 6.2.9. BIOSVersion 6.2.10. BootCodeVersion 6.2.11. FirmwareStatus 6.2.12. iSCSIVersionMin 6.2.13. iSCSIVersionMax 6.2.14. MaxCDBLength 6.2.15. MaxMTUSize 6.2.16. LDTO (for ESX) 6.2.17. LDTO (for SOLARIS) 6.2.18. LDTO (for WINDOWS) 6.2.19. DefaultETO (for ESX) 6.2.20. DefaultETO (for WINDOWS) 6.2.21. DefaultETO (for SOLARIS) 6.2.22. VLDCapable 6.2.23. VLDEnabled 6.2.24. SequenceNumber 6.2.25. TimeStamp 6.2.26. Severity 6.2.27. Description 6.2.28. ErrorCode 6.2.29. VendorID (for ESX) 6.2.30. DeviceID (for ESX) 6.2.31. SubsysDeviceID (for ESX) 6.2.32. SubsysVendorID (for ESX) 6.2.33. BusNumber (for ESX) 6.2.34. DeviceNumber (for ESX) 6.2.35. FunctionNumber (for ESX) 6.2.36. DriverName (for ESX) 6.2.37. DriverVersion (for ESX) 6.2.38. IfName (for ESX) 6.2.39. MACAddress (for ESX) 6.2.40. VLANPriority (for ESX) 6.2.41. MaxBitsPerSecond (for ESX) 6.2.42. MaxPacketsPerSecond (for ESX) 6.2.43. DriverName 6.2.44. DriverVersion 6.2.45. DHCPServerAvailable 6.2.46. DHCPObtainNewIPAddress 6.2.47. DHCPEnabled 6.2.48. InitiatorIPAddress 6.2.49. InitiatorSubnetMask 6.2.50. DefaultGateway 6.2.51. IPVersionSupported 6.2.52. VLANID 6.2.53. PortSpeed 6.2.54. PortMaxSpeed 6.2.55. MaxFrameSize 6.2.56. LinkStatus 6.2.57. ActivePort 6.2.58. MACAddress 6.2.59. IPAddress 6.2.60. SubnetMask 6.2.61. Gateway 6.2.62. IPAddress 6.2.63. MACAddress 6.2.64. VendorID 6.2.65. DeviceID 6.2.66. SubsysDeviceID 6.2.67. SubsysVendorID 6.2.68. BusNumber 6.2.69. DeviceNumber 6.2.70. FunctionNumber

Page 7: PRIMERGY BX600 10GbE LAN I/O Module (PCIe) - Fujitsumanuals.ts.fujitsu.com/file/8372/bx-10gbe-sm-clp-ref-win08.pdf · PRIMERGY BX600 10GbE LAN I/O Module ... Microsoft Windows Server

6.2.71. iSNSEnabled 6.2.72. IPAddress 6.2.73. PortNumber 6.2.74. Enabled 6.2.75. IfName (for ESX) 6.2.76. InitiatoriSCSIName 6.2.77. InitiatorAlias 6.2.78. DefaultiSCSIName 6.2.79. InitialR2T 6.2.80. ImmediateData 6.2.81. MaxConnections 6.2.82. MaxOutstandingR2T 6.2.83. FirstBurstLength 6.2.84. MaxBurstLength 6.2.85. DefaultTime2Wait 6.2.86. DefaultTime2Retain 6.2.87. ErrorRecoveryLevel 6.2.88. DataPDUInOrder 6.2.89. DataSequenceInOrder 6.2.90. HeaderDigest 6.2.91. DataDigest 6.2.92. MaxRecvDataSegmentLength 6.2.93. TCPWindowSize 6.2.94. InitialR2T 6.2.95. ImmediateData 6.2.96. HeaderDigest 6.2.97. DataDigest 6.2.98. AuthenticationMethod 6.2.99. InitiatorCHAPName 6.2.100. InitiatorSecret 6.2.101. TargetCHAPName 6.2.102. TargetSecret 6.2.103. MaxBytesPerSecond 6.2.104. MaxIosPerSecond 6.2.105. NodeRoles 6.2.106. PortalCount 6.2.107. NodeCount 6.2.108. SessionCount 6.2.109. SessionFailureCount 6.2.110. LastSessionFailureType 6.2.111. LastSessionRmtNodeName 6.2.112. SessionDigestErrors 6.2.113. SessionConnectionTimeout 6.2.114. SessionFormatErrors 6.2.115. LoginFailures 6.2.116. LastFailureTime 6.2.117. LastFailureType 6.2.118. LastTgtFailureName 6.2.119. LastTgtFailureAddr 6.2.120. LoginAcceptRsps 6.2.121. LoginOtherFailRsps 6.2.122. LoginRedirectRsps 6.2.123. LoginAuthFailRsps 6.2.124. LoginAuthFails 6.2.125. LoginNegoFails 6.2.126. LogoutNormals 6.2.127. LogoutOthers 6.2.128. PortRowStatus 6.2.129. PortalRole 6.2.130. PortalProtocol 6.2.131. PortalTag 6.2.132. TargetIPAddress 6.2.133. TargetPortNumber

Page 8: PRIMERGY BX600 10GbE LAN I/O Module (PCIe) - Fujitsumanuals.ts.fujitsu.com/file/8372/bx-10gbe-sm-clp-ref-win08.pdf · PRIMERGY BX600 10GbE LAN I/O Module ... Microsoft Windows Server

6.2.134. PortalGroupTag 6.2.135. Persistent 6.2.136. InitialR2T 6.2.137. ImmediateData 6.2.138. HeaderDigest 6.2.139. DataDigest 6.2.140. AuthenticationMethod 6.2.141. InitiatorCHAPName 6.2.142. InitiatorSecret 6.2.143. TargetCHAPName 6.2.144. TargetSecret 6.2.145. InitialR2T 6.2.146. ImmediateData 6.2.147. MaxConnections 6.2.148. MaxOutstandingR2T 6.2.149. FirstBurstLength 6.2.150. MaxBurstLength 6.2.151. DefaultTime2Wait 6.2.152. DefaultTime2Retain 6.2.153. ErrorRecoveryLevel 6.2.154. DataPDUInOrder 6.2.155. DataSequenceInOrder 6.2.156. SessionDirection 6.2.157. CmdPdus 6.2.158. RspPdus 6.2.159. TxDataOctetsHigh 6.2.160. RxDataOctetsHigh 6.2.161. DigestErrors 6.2.162. CxnTimeoutErrors 6.2.163. SessionTargetAlias 6.2.164. AuthenticationMethod 6.2.165. HeaderDigest 6.2.166. DataDigest 6.2.167. MaxRecvDataSegmentLength 6.2.168. TCPWindowSize 6.2.169. TCPMSS 6.2.170. iSCSIConnectionID 6.2.171. Status 6.2.172. SourcePortNumber 6.2.173. DestinationPortNumber 6.2.174. SourceIPAddress 6.2.175. DestinationIPAddress 6.2.176. RedirectedDestinationPort 6.2.177. RedirectedDestinationIPAddress 6.2.178. SessionTSIH 6.2.179. ISIDQualifier 6.2.180. SessionInitiatorName 6.2.181. SessionStatus 6.2.182. iSCSIBoot 6.2.183. Persistent 6.2.184. LUNNumber 6.2.185. LUNSize 6.2.186. DeviceVendorName 6.2.187. DeviceModelNumber 6.2.188. LUNName (for ESX) 6.2.189. LUNSerialNumber 6.2.190. TargetISCSIName 6.2.191. TargetAlias 6.2.192. ETO (for ESX) 6.2.193. ETO (for WINDOWS) 6.2.194. ETO (for SOLARIS) 6.2.195. InitialR2T 6.2.196. ImmediateData

Page 9: PRIMERGY BX600 10GbE LAN I/O Module (PCIe) - Fujitsumanuals.ts.fujitsu.com/file/8372/bx-10gbe-sm-clp-ref-win08.pdf · PRIMERGY BX600 10GbE LAN I/O Module ... Microsoft Windows Server

6.2.197. HeaderDigest 6.2.198. DataDigest 6.2.199. InitiatorCHAPName 6.2.200. InitiatorSecret 6.2.201. TargetCHAPName 6.2.202. TargetSecret 6.2.203. AuthenticationMethod 6.2.204. IPAddress 6.2.205. PortNumber 6.2.206. PortMacAddress 6.2.207. Persistent

6.3. Data Types 6.4. Common Error Messages

1. Revision History

• July 01, 2008 1. Added an error message for OEMSEAddTarget, OEMSEAddSendTargetPortal

commands. • June 30, 2008

1. Added two properties 'iSCSIStatus' and 'NICStatus' under /LogicalHBA to show the enable/disable status of iSCSI and NIC respectively.

• June 30, 2008 1. Added property 'IfName' in iSCSI/PhysicalHBA/ and

'PhysicalHBAInstanceNumber' in Session/. • June 19, 2008

1. Added optional param "LogicalHBAInstanceNumber" for OEMSEEraseConfiguration.

• June 18, 2008 1. Changed the description for the property 'LUNName'.

• June 06, 2008 1. Added one property 'SerialNumber' under iSCSI/PhysicalHBA/. 2. Added one error message for OEMSEEnableiSCSI.

• June 03, 2008 1. Added one more property 'LUNName' under LUN node only for ESX.

• May 27, 2008 1. Added two actions SetSTPPersistent and DeleteSTPPersistent under

SendTargetPortal node. 2. Added one property PersistencyStatus under SendTargetPortal node. 3. Added two error messages for OEMSESetSTPPersistent and

OEMSEDeleteSTPPersistent. • May 20, 2008

1. Added one more error message for OEMSESetPersistent, OEMSELogin, OEMSERefreshAvailableTargets and OEMSEDiscoverTargets commands.

• April 04, 2008 1. Added one more error message for OEMSELogin,

OEMSERefreshAvailableTargets and OEMSEDiscoverTargets commands. • March 13, 2008

1. Added one more error message for OEMSEConfigureIPAddress and OEMSEConfigureDHCP commands.

2. Changed the description for OEMSESaveConfig command. • February 14, 2008

1. Removed the properties NodeTransportType and LastTgtFailureType from LogicalHBA0/iSCSI/PhysicalHBA0/SNMP node.

• January 31, 2008 1. Removed the actions AddConnection and DeleteConnection from Session

group. • January 21, 2008

1. Changed the description for the commands EnableiSCSI, DisableiSCSI, DisableNIC, AddRouteTableEntry and DeleteRouteTableEntry.

Page 10: PRIMERGY BX600 10GbE LAN I/O Module (PCIe) - Fujitsumanuals.ts.fujitsu.com/file/8372/bx-10gbe-sm-clp-ref-win08.pdf · PRIMERGY BX600 10GbE LAN I/O Module ... Microsoft Windows Server

• January 11, 2008 1. Changed the description for the commands DiscoveryiSNSThruDHCP,

AddiSNSEntry, DeleteiSNSEntry, AddSendTargetPortal, DeleteSendTargetPortal and RefreshAvailableTargets.

• January 05, 2008 1. Changed the description for the properties InitialR2T, ImmediateData,

HeaderDigest and DataDigest. • January 02, 2008

1. Added one more error string 'Setting ETO failed' for Login command. • December 18, 2007

1. Removed IPSecEnabled property from InitiatorDefaultLoginOptions and ConnectionNegotiatedLoginOptions groups.

• December 10, 2007 1. Added a new error message for "OEMSEReScanLUNS" command. It will fail

with the error message when there is no sessions available to that target. • December 07, 2007

1. Help text changed for InitiatoriSCSIName and InitiatorAlias properties. 2. Help text changed for AddSendTargetPortal and DiscoverTargets actions.

• November 30, 2007 1. Added an action DiscoverTargets under SendTargetPortal group. 2. Authentication group is added under SendTargetPortal group.

• November 22, 2007 1. Changed the datatype for PortIdentifier to integer. 2. Corrected the maximum value for PortIdentifier property to 1.

• November 16, 2007 1. Datatype for property MACAddress changed to string. 2. Corrected the letter case for all datatypes. 3. Removed the datatypes U16 and U32 and added integer instead of them.

• November 14, 2007 1. Property name IsBoot under PersistentLogin group changed to iSCSIBoot.

• November 13, 2007 1. SLPEnabled and iSNSEnabled properties display and accept strings Yes or

No instead of 1 or 0 or blank. 2. Changed the default value of 'SLPEnabled' and 'iSNSEnabled' to No.

• November 2, 2007 1. Added an optional parameter "VLANID" to OEMSEConfigureIPAddress

command and changed the property "VLANID" to read-only. 2. Changed the default value of "VLANID" property to 0.

• October 26, 2007 1. Removed action OEMSESaveTCPIPConfig from TCPIPConfiguration and

added two new actions OEMSEConfigureIPAddress to configure the IPAddress, SubnetMask and DefaultGateway manually and OEMSEConfigureDHCP to enable or disable DHCP.

2. Properties in TCPIPConfiguration are made read-only (except VLANID). • October 22, 2007

1. Added a new error message for "OEMSEEraseConfiguration" command. It will fail with an error message when there are active sessions.

2. Updated help descriptions for ARP entries, route table, PCI, event log and SNMP

• October 19, 2007 1. Added "Default ETO" property in BladeEngine group

• October 17, 2007 1. Added "Possible Error Messages" section for commands in Basic Commands

chapter (set, show, etc..) . 2. Removed the "Success" and "Read only Property" from Common Error

Messages list. • October 15, 2007

1. lower case sm-clp changed to upper case SM-CLP 2. Help text changed for set command 3. -default option is removed 4. -f option is removed

• October 10, 2007

Page 11: PRIMERGY BX600 10GbE LAN I/O Module (PCIe) - Fujitsumanuals.ts.fujitsu.com/file/8372/bx-10gbe-sm-clp-ref-win08.pdf · PRIMERGY BX600 10GbE LAN I/O Module ... Microsoft Windows Server

1. Added Revision history section to the document 2. Error message changed when a trying to set a read-only property from

"Error: Readonly Property" to "Error: Read only Property" • October 05, 2007

1. Output format for QOS properties, MaxBytesPerSecondPeriSCSI and MaxIosPerSecondPeriSCSI removed description in paranthesis.

2. Help text changed for Login parameters InitialR2T, ImmediateData, HeaderDigest and DataDigest

• October 03, 2007 1. HeaderDigest and DataDigest properties now display and accept strings

"None" and "CRC32C" instead of 0 and 1 2. Help text updated for EnableDHCP property 3. VLDEnabled property will display and accept strings "Yes" and "No" instead

of 0 and 1 • September 26, 2007

1. Help text updated for OEMSESetPersistent verb 2. Property names IsVLDEnabled and IsVLDEnabledOnFlash changed to

VLDCapable and VLDEnabled • September 24, 2007

1. Help text updated for iSCSIBoot property • September 23, 2007

1. Help text updated for FirmwareVersionOnFlash property 2. isBoot property name changed to iSCSIBoot 3. SRANumber property is renamed to LUNNumber 4. Help text updated for LUNNumber and LUNSize

• September 21, 2007 1. Removed EstimatedThroughPut property 2. Modified Connection status to display decoded string

• September 18, 2007 1. CHAP settings removed from InitiatorDefaultLoginOptions group 2. Help text modified for CHAP method, CHAP settings, ImmediateData and

InitialR2T login parameters • September 15, 2007

1. ETO (Extended Timeout) and LDTO (Link Down TimeOut) properties added in BladeEngine and Target groups

• August 4, 2007 1. Verbs OEMSESetPersistence and OEMSEDeletePersistentLogin changed to

OEMSESetPersistent and OEMSEDeletePersistent • August 10, 2007

1. Login Parameters "InitialR2T" and "ImmediateData" are modified from read-only to read-write properties.

• August 4, 2007 1. Verbs OEMSESetPersistence and OEMSEDeletePersistentLogin changed to

OEMSESetPersistent and OEMSEDeletePersistent • August 3, 2007

1. Maximum entries for ARPTableEntry increased to 64. • July 27, 2007

1. Action added to Upgrade Flash ROM in BladeEngine group. • July 18, 2007

1. Changed allowable range of MaxIosPerSecondPeriSCSI and MaxBytesPerSecondPeriSCSI

• July 9, 2007 1. Changed default values of login parameters as per iSCSI spec (MBL and

datapduinorder) • June 26, 2007

1. Help text modified for IPVersionSupported property in /LogicalHBA0/iSCSI/PhysicalHBA0/Network/TCPIPConfiguration

2. Introduction

Page 12: PRIMERGY BX600 10GbE LAN I/O Module (PCIe) - Fujitsumanuals.ts.fujitsu.com/file/8372/bx-10gbe-sm-clp-ref-win08.pdf · PRIMERGY BX600 10GbE LAN I/O Module ... Microsoft Windows Server

2.1. Glossary

This section describes the meaning of some of the product and protocol specific terms that are used in this document.

Property : An entity in the BladeEngine software that has a value associated with it. A property can be either read-only or read-write. A property can be one of the data type listed in Data Types section in Appendix section.

Verb : It is an SM-CLP command. All the verbs that are exported by BladeEngine software are termed as OEMSEVerbs.

Group : A logical entity that holds all the related properties and verbs. There can be groups within groups (termed as sub-groups). Groups are organized heirachically in a tree format.

SM-CLP target : SM-CLP document uses the term target to refer to groups. To avoid confusion, this document uses SM-CLP target or groups to refer the same.

Initiator : A term used in iSCSI protocol to represent the entity that issues SCSI commands.

Target : A term used in iSCSI protocol to represent the entity that services SCSI commands to an initiator.

Data Types used in this document are listed with their description in the Appendix section.

2.2. Document Convention

This document uses the following conventions to describe command syntax

Convention Meaning

< > Within syntax description, indicates values that an user specifies. For example, show < property >

[ ] Within syntax description, indicates optional keywords that can be used with the command. For example, show [-d < target >]

| Within syntax descriptions, the pipe symbol represents a choice to select one keyword or variable to the left or right of the symbol. (The keyword or variable can be either optional or required.) For example, show [-d < targets > | -l < n | all >]

Table 1: Document Convention

2.3. Hardware and Software Dependencies

It is required that the BladeEngine Software be installed on your system. The SM-CLP username and password must be set up during software installation in order for the SM-CLP Client to access the server.

3. Using the BladeEngine SM-CLP Client This Chapter describes how to access the BladeEngine SM-CLP server using SM-CLP Client.

The features that SM-CLP offers are:

• Scriptability Allows the execution of script files. • Usability Allows tab completions on commands and parameters

Page 13: PRIMERGY BX600 10GbE LAN I/O Module (PCIe) - Fujitsumanuals.ts.fujitsu.com/file/8372/bx-10gbe-sm-clp-ref-win08.pdf · PRIMERGY BX600 10GbE LAN I/O Module ... Microsoft Windows Server

• Command Line options Accepts command line options/arguments and additional command line parameters

3.1. Connecting to the BladeEngine server using SM-CLP Client

SM-CLP connects automatically to the server that is running BladeEngine software with a typical or custom install of the BladeEngine Server software. Sm-CLP can be invoked by just typing ./client at the prompt. The username and password created for connecting to the server.

To use SM-CLP Client with Windows Server 2008:

1. Install the BladeEngine Server Software by using the Installation Utility. You will be setting up your SM-CLP username and password during SM-CLP Client installation. For more information, refer to the ServerEngines BladeEngine Software Installation Guide.

2. After you installed the SM-CLP Client, you can run SM-CLP by double-clicking the SM-CLP Client shortcut icon on your desktop, or by double-clicking the .exefile in your Client directory.

3. When you have connected, the SM-CLP banner will appear. Use the show command to display SM-CLP options or other commands.

To use SM-CLP Client with Linux or ESX Server:

1. Install the BladeEngine Server Software by using the Installation Utility. You will be setting up your SM-CLP username and password during SM-CLP Client installation. For more information, refer to the ServerEngines BladeEngine Software Installation Guide.

2. At a command prompt type: cd/opt/ServerEngines/BladeEngine/smclp/client. 3. Launch SM-CLP Client by typing: ./client. 4. When you have connected, the SM-CLP banner will appear. Use the show

command to display SM-CLP options and other commands.

To use SM-CLP Client with Solaris 10:

1. Install the BladeEngine Server Software by using the Installation Utility. You will be setting up your SM-CLP username and password during SM-CLP Client installation. For more information, refer to the ServerEngines BladeEngine Software Installation Guide.

2. At a command prompt type: cd/opt/ServerEngines/BladeEngine/smclp/client. 3. Launch SM-CLP Client by typing: ./client. 4. When you have connected, the SM-CLP banner will appear. Use the show

command to display SM-CLP options and other commands.

3.2. SM-CLP Client Command Line Options

SM-CLP can be invoked by typing ./client on the command line as described below:

SM-CLP Syntax:

./client [-h] [-u < username >] [-p < password >] [-f < scriptfile >] [-o < outputfile >] [-s < host:port >] [-t < protocol > ] [-x < command >]

Option Description -h Displays help for this command.

-u Specifies the username for transport authentication. Without this option, the client utility will prompt for a username. This is typically used to execute an SM-CLP script with a remote

Page 14: PRIMERGY BX600 10GbE LAN I/O Module (PCIe) - Fujitsumanuals.ts.fujitsu.com/file/8372/bx-10gbe-sm-clp-ref-win08.pdf · PRIMERGY BX600 10GbE LAN I/O Module ... Microsoft Windows Server

transport.

-p Specifies the password for transport authentication. Without this option, the client utility will prompt for a password. This is typically used to execute an SM-CLP script with a remote transport.

-f Specifies an SM-CLP script file as an argument. The client will exit after execution of the SM-CLP commands in the script file.

-o Specifies a filename to which SM-CLP output will be redirected. The "o option can only be used in conjunction with the "f option. The file will be created on the machine from which the client utility is executed.

-s Specifies the IP address and an optional TCP port number to which the client will connect.

-t

Specifies the protocol that the client utility will use to connect to the SM-CLP server. If no protocol is specified, then console will be used. Possible transport are console, SSH and telnet. Console option will connect to the SM-CLP server running on the local system without the use of a transport like telnet or SSH and it will not prompt the user for an IP address or log-in credentials.

-x

Specifies an SM-CLP command for execution. The command can be a basic or OEM specific command. This option cannot be used with the f option. A forward slash is required for any command that uses a quotation Mark. Note the following example for the OEMSEping command.

client -x "OEMSEping -OEMSEparams IPAddress=\"192.168.0.1\" /BladeEngine0/iSCSIPhysicalHBA0/Network".

Table 2: SM-CLP Options

SM-CLP commands can be run in three different modes as listed below:

• Immediate

In Immediate mode the SM-CLP command is given as an SM-CLP option with the required parameters. SM-CLP will exit the program after executing the command. If the command did not execute for some reason or if there is a syntax error then SM-CLP terminates with the appropriate error message.

Example:

./client -u smclp -p smclp -s localhost show bladeengine0

will execute the command to display bladeengine0 properties and exit.

• Script

A script file can be supplied followed by a "-f" SM-CLP option. The Client will execute all the SM-CLP commands in the script file and exit. If exit is not provided at the end of the script file then it is automatically inserted. The script will be aborted if a command encounters with an error.

Example:

-f < scriptfile >

will execute all the SM-CLP commands in scriptfile and exit.

• Interactive

The Client will enter into an interactive mode, if neither SM-CLP command nor script file is provided as an option. The Client will accept SM-CLP commands and execute them in the interactive shell. The Client will remain in interactive mode

Page 15: PRIMERGY BX600 10GbE LAN I/O Module (PCIe) - Fujitsumanuals.ts.fujitsu.com/file/8372/bx-10gbe-sm-clp-ref-win08.pdf · PRIMERGY BX600 10GbE LAN I/O Module ... Microsoft Windows Server

until an exit command is given. SM-CLP supports tab completions and command history.

Example:

./client

will enter interactive mode.

The BladeEngine SM-CLP follows the specifications as defined in the Desktop Management Task Force (DMTF) Server Management Command Line Protocol (SM-CLP) standard 1.0a.

All the SM-CLP commands and options are not case sensitive.

Parameters that are decimal numbers will also accept hexadecimal values with a '0x' as prefix. For ex: 0xa for decimal 10

Quoted strings are treated as single parameter for the commands that accept character inputs regardless of the space in the string.

For string parameters quotes are optional, unless there is a space in the string. Space is used as a string termination, unless it is within quotes.

3.3. Accessing Help

SM-CLP provides generic help and context help. Help can be obtained by simply typing

help

at the interactive command prompt.

To obtain a context help type the following at the command prompt:

help < group > < property >

to get help on a particular property

-or-

help < group > < verb >

to get help on a particular command.

If group name is not given it is assumed to be the current group. Refer to help command for details.

4. Basic Commands This chapter describes the basic commands that are provided by SM-CLP. The syntax that is provided in this chapter is for script file and interactive mode of operation. For Immediate mode of operation the same syntax can be provided as command line argument within double quotes.

4.1. common options

Page 16: PRIMERGY BX600 10GbE LAN I/O Module (PCIe) - Fujitsumanuals.ts.fujitsu.com/file/8372/bx-10gbe-sm-clp-ref-win08.pdf · PRIMERGY BX600 10GbE LAN I/O Module ... Microsoft Windows Server

The following are the common options that can be used with any of the commands

Parameter Description -x | -examin Examines and reports whether the command can be executed. -h | -help Provides help on the command -o | -output < output_arguments >

Takes the output file format. See "output_arguments" below for supported arguments.

-v | -version Displays the SM CLP version number used by the CLI

4.2. output arguments

The following are the arguments for -o or -output option. If more than one arguments are used then they should be separated by commas with no spaces.

Parameter Description format=< value >

Format controls the structure of the output text. The only < value > supported format is "text"

terse Selects the level of detail included in the output to terse. This option cannot be used in conjunction with verbose.

verbose Selects the level of detail included in the output to verbose. This option cannot be used in conjunction with terse.

error The option to select the level of detail included in the output to error is not supported.

language=< value >

Language selects the translation of text. < value > is a 3-character string identifier of language are specified in ISO 639.2. The only < value > supported is "eng" (for English).

begin When multiple items are returned in the output begin/end control where to start in the list. "end" is not supported.

order=< value >

When multiple items are returned in the output order controls the order of those items. The only < value > supported is "default". "reverse" is not supported.

count=< value >

When multiple items are returned in the output number controls the number of items returned. Default < value > is "all" which is supported. Any other value is not supported.

Examples

The following are some examples of usage of output arguments:

To select the level of detail included in the output to verbose: client "OEMSESaveTCPConfig -o verbose" will execute OEMSESaveTCPConfig verb and display detailed output message.

To do the same in the interactive shell of Command Line Interface: OEMSESaveTCPConfig -o verbose

4.3. cd

Command

cd

Description

This command sets the current group to the value provided in the parameter. If no parameter is given it displays the current working group.

Syntax

cd [common_options] [ -default] [SM-CLP target]

Page 17: PRIMERGY BX600 10GbE LAN I/O Module (PCIe) - Fujitsumanuals.ts.fujitsu.com/file/8372/bx-10gbe-sm-clp-ref-win08.pdf · PRIMERGY BX600 10GbE LAN I/O Module ... Microsoft Windows Server

Options

[common_options]

Parameter Description -default takes the current working group to default which is root SM-CLP target

Optional input that indicates the SM-CLP target group for the given command. This overrides the current group. ".." indcates parent group. "/" indicates root group.

Required Parameters

None

Optional Parameters

None

Possible Error Messages

Common Error Messages

4.4. show

Command

show

Description

This command shows the property value for the property provided in the string. If no option is given then it displays the list of all the groups and properties available under the current group.

Syntax

show [common_options] [ -default] [ -d] [ -l] [SM-CLP target]

Options

[common_options]

Parameter Description -default function is not defined in SM-CLP 1.0a document

-d

This option accepts a filter that is used to display the output. Valid values for Filters are

• targets Displays all the SM-CLP targets • properties Displays all the properties • verbs Displays all the verbs (commands) • properties=< property name > Displays the property by the given < property

name >. • properties=< property name >==< value > Displays the property by name <

property name > and that has value given in < value >. For example properties=linkState==0 will display all the ports whose link is down (linkState=0). < value > string is case sensitive. Use double quotes around the < value > string if there is a space in it.

-l This option specifies the level of subgroups the show command has to traverse to display.

Page 18: PRIMERGY BX600 10GbE LAN I/O Module (PCIe) - Fujitsumanuals.ts.fujitsu.com/file/8372/bx-10gbe-sm-clp-ref-win08.pdf · PRIMERGY BX600 10GbE LAN I/O Module ... Microsoft Windows Server

The default value is 1 which displays just the current group. The possible values for this option are

• 1 to n Displays the given levels of sub-groups. "n" should be an integer. • all Displays all the sub-groups recursively.

SM-CLP target

Optional input that indicates the SM-CLP target group for the given command. This overrides the current group. ".." indcates parent group. "/" indicates root group.

Required Parameters

None

Optional Parameters

None

Possible Error Messages

Common Error Messages

4.5. set

Command

set

Description

This command sets the given property with the given value. These values will be persistent unless the user performs an OEMSEEraseConfiguration command in SM-CLP or clears the configuration in iSCSISelect. Any exception to this will be listed in the help. Set command will fail on read-only properties.

Syntax

set [common_options] [SM-CLP target] [< property > ] = [< value > ]

Options

[common_options]

Parameter Description SM-CLP target

Optional input that indicates the SM-CLP target group for the given command. This overrides the current group. ".." indcates parent group. "/" indicates root group.

< property > The property to be set. Type "show -d properties -l all" at the root group to get a list of all properties. Type "show -d properties" to see properties within current group only.

< value > The value is specific to the given command. Please type "help [property]" for applicable values.

Required Parameters

None

Optional Parameters

Page 19: PRIMERGY BX600 10GbE LAN I/O Module (PCIe) - Fujitsumanuals.ts.fujitsu.com/file/8372/bx-10gbe-sm-clp-ref-win08.pdf · PRIMERGY BX600 10GbE LAN I/O Module ... Microsoft Windows Server

None

Possible Error Messages

Common Error Messages Read only property

4.6. OEMSESaveConfig

Command

OEMSESaveConfig

Description

This command saves the BladeEngine controller configuration to the given file name as an SM-CLP script. The SM-CLP script can be used to restore the BladeEngine controller configuration using the ServerEngines client application. Execute the client utility with the -f option. It is important to note that CHAP secrets will be stored in clear text in the SM-CLP script file. Hence, adequate precautions must be taken to protect this information when storing and using the script file. Also note that the SM-CLP script cannot be used to enable DHCP as a reboot is required when enabled DHCP via SM-CLP. Therefore enable DHCP using iSCSISelect or SM-CLP prior to executing the script.

Syntax

OEMSESaveConfig [common_options] -OEMSEparams File="< value >"

Options

[common_options]

Parameter Description -OEMSEparams

takes in additional parameters as arguments as listed below in the Parameters table of this section. The parameters has to be entered in a key=value format.

Required Parameters

Parameter Name

Data Type

Min Max Default Description

File String N/A N/A N/A string input that contains the filename with fully qualified path where the configuration will be saved.

Optional Parameters

None

Possible Error Messages

Common Error Messages

4.7. help

Command

help

Page 20: PRIMERGY BX600 10GbE LAN I/O Module (PCIe) - Fujitsumanuals.ts.fujitsu.com/file/8372/bx-10gbe-sm-clp-ref-win08.pdf · PRIMERGY BX600 10GbE LAN I/O Module ... Microsoft Windows Server

Description

This command displays generic help and context help on a particular SM-CLP target property or verb. help command without a parameter will display generic help on how to use help.

Syntax

help [common_options] [group] [property | verb]

Options

[common_options]

Parameter Description

group The SM-CLP target for which the property or verb belongs. The valid list of SM-CLP targets are listed in the group table.

property | verb

Context help will be displayed for the given property or verb. The valid list of properties and verbs are listed in the property table and verb table of the document. The properties list can be obtained online by typing "show -d properties -l all". The verb list can be obtained online by typing "show -d verbs -l all".

Required Parameters

None

Optional Parameters

None

Possible Error Messages

Common Error Messages

4.8. version

Command

version

Description

This command will display the SM-CLP version number. This command does not take in any parameters.

Syntax

version [common_options]

Options

[common_options]

Required Parameters

None

Page 21: PRIMERGY BX600 10GbE LAN I/O Module (PCIe) - Fujitsumanuals.ts.fujitsu.com/file/8372/bx-10gbe-sm-clp-ref-win08.pdf · PRIMERGY BX600 10GbE LAN I/O Module ... Microsoft Windows Server

Optional Parameters

None

Possible Error Messages

Common Error Messages

4.9. exit

Command

exit

Description

This command exits the interactive mode (or the script if running in the script mode). It does all the clean up required to do a graceful exit.

Syntax

exit [common_options]

Options

[common_options]

Required Parameters

None

Optional Parameters

None

Possible Error Messages

Common Error Messages

5. OEMSE Commands This chapter describes the OEMSE commands (verbs) for BladeEngine Software that are provided by the CLI. The commands has to be run in the particular group (smclp-target). To go the particular group use 'cd' command. CLI allows to execute the OEMSE command from any other group, provide the context (smclp-target) is given as an input to the command (as shown in the syntax of the OEMSE commands). The group (smclp-target) map tree is shown in the Group Maps chapter.

5.1. Group Maps

The following tree represents the SM-CLP targets, properties and verbs with their associations to each other. Convention Meaning * Property ! OEMSECommand

Page 22: PRIMERGY BX600 10GbE LAN I/O Module (PCIe) - Fujitsumanuals.ts.fujitsu.com/file/8372/bx-10gbe-sm-clp-ref-win08.pdf · PRIMERGY BX600 10GbE LAN I/O Module ... Microsoft Windows Server

[< n > - < m >] Multi-instance group starting with 'n'-th instance and with max of 'm' instances (< parameter >) Mandatory parameter to the action ([< parameter >]) Optional parameter to the action

ROOT |-> *MILIServiceVersion (Read-Only) |-> *MILIHierarchyVersion (Read-Only) |-> BladeEngine[0-7] |-> *Manufacturer (Read-Only) |-> *ModelNumber (Read-Only) |-> *Description (Read-Only) |-> *SerialNumber (Read-Only) |-> *ActiveFirmwareVersion (Read-Only) |-> *FirmwareVersionOnFlash (Read-Only) |-> *BIOSVersion (Read-Only) |-> *BootCodeVersion (Read-Only) |-> *FirmwareStatus (Read-Only) |-> *iSCSIVersionMin (Read-Only) |-> *iSCSIVersionMax (Read-Only) |-> *MaxCDBLength (Read-Only) |-> *MaxMTUSize (Read-Only) |-> *LDTO (Read-Only) (for ESX) |-> *LDTO (Read-Only) (for SOLARIS) |-> *LDTO (Read-Only) (for WINDOWS) |-> *DefaultETO (Read-Only) (for ESX) |-> *DefaultETO (Read-Only) (for WINDOWS) |-> *DefaultETO (Read-Only) (for SOLARIS) |-> *VLDCapable (Read-Only) |-> *VLDEnabled |-> !OEMSEUpgradeFlashROM ( UFIFileName ) |-> EventLog | |-> EventLogEntry[0-1023] | | |-> *SequenceNumber (Read-Only) | | |-> *TimeStamp (Read-Only) | | |-> *Severity (Read-Only) | | |-> *Description (Read-Only) | | |-> *ErrorCode (Read-Only) | |-> !OEMSERefreshEventLog ( ) | |-> !OEMSEClearEventLog ( ) |-> NICPhysicalHBA[0-7] | |-> PCI | | |-> *VendorID (Read-Only) (for ESX) | | |-> *DeviceID (Read-Only) (for ESX) | | |-> *SubsysDeviceID (Read-Only) (for ESX) | | |-> *SubsysVendorID (Read-Only) (for ESX) | | |-> *BusNumber (Read-Only) (for ESX) | | |-> *DeviceNumber (Read-Only) (for ESX) | | |-> *FunctionNumber (Read-Only) (for ESX) | |-> Driver | | |-> *DriverName (Read-Only) (for ESX) | | |-> *DriverVersion (Read-Only) (for ESX) | |-> LogicalHBA[0-15] | |-> *IfName (Read-Only) (for ESX) | |-> *MACAddress (for ESX) | |-> *VLANPriority (for ESX) | |-> QoS | |-> *MaxBitsPerSecond (for ESX) | |-> *MaxPacketsPerSecond (for ESX) |-> iSCSIPhysicalHBA[0-7] |-> Driver | |-> *DriverName (Read-Only) | |-> *DriverVersion (Read-Only) |-> Network

Page 23: PRIMERGY BX600 10GbE LAN I/O Module (PCIe) - Fujitsumanuals.ts.fujitsu.com/file/8372/bx-10gbe-sm-clp-ref-win08.pdf · PRIMERGY BX600 10GbE LAN I/O Module ... Microsoft Windows Server

| |-> DHCP | | |-> *DHCPServerAvailable (Read-Only) | | |-> *DHCPObtainNewIPAddress (Read-Only) | |-> TCPIPConfiguration | | |-> *DHCPEnabled (Read-Only) | | |-> *InitiatorIPAddress (Read-Only) | | |-> *InitiatorSubnetMask (Read-Only) | | |-> *DefaultGateway (Read-Only) | | |-> *IPVersionSupported (Read-Only) | | |-> *VLANID (Read-Only) | | |-> !OEMSEConfigureIPAddress ( IPAddress SubnetMask [Gateway] [VLANID] ) | | |-> !OEMSEConfigureDHCP ( EnableDHCP ) | |-> NICConfiguration | | |-> *PortSpeed (Read-Only) | | |-> *PortMaxSpeed (Read-Only) | | |-> *MaxFrameSize (Read-Only) | | |-> *LinkStatus (Read-Only) | | |-> *ActivePort (Read-Only) | | |-> *MACAddress (Read-Only) | | |-> !OEMSERefreshNICConfig ( ) | |-> RouteTable | | |-> RouteTableEntry[0-15] | | | |-> *IPAddress (Read-Only) | | | |-> *SubnetMask (Read-Only) | | | |-> *Gateway (Read-Only) | | |-> !OEMSEAddRouteTableEntry ( IPAddress SubnetMask Gateway ) | | |-> !OEMSEDeleteRouteTableEntry ( InstanceNumber ) | | |-> !OEMSERefreshRouteTableEntry ( ) | |-> ARPTable | | |-> ARPTableEntry[0-63] | | | |-> *IPAddress (Read-Only) | | | |-> *MACAddress (Read-Only) | | |-> !OEMSEAddARPTableEntry ( IPAddress MACAddress ) | | |-> !OEMSEDeleteARPTableEntry ( InstanceNumber ) | | |-> !OEMSERefreshARPTableEntry ( ) | |-> !OEMSEPing ( IPAddress ) |-> PCI | |-> *VendorID (Read-Only) | |-> *DeviceID (Read-Only) | |-> *SubsysDeviceID (Read-Only) | |-> *SubsysVendorID (Read-Only) | |-> *BusNumber (Read-Only) | |-> *DeviceNumber (Read-Only) | |-> *FunctionNumber (Read-Only) |-> iSNS | |-> *iSNSEnabled | |-> iSNSServer[0-3] | | |-> *IPAddress (Read-Only) | | |-> *PortNumber (Read-Only) | |-> !OEMSEDiscoveryiSNSThruDHCP ( ) | |-> !OEMSEAddiSNSServer ( IPAddress PortNum ) | |-> !OEMSEDeleteiSNSServer ( InstanceNumber ) |-> !OEMSEEraseConfiguration ( [LogicalHBAInstanceNumber] ) |-> LogicalHBA[0-15] |-> *Enabled |-> *IfName (Read-Only) (for ESX) |-> InitiatoriSCSIName | |-> *InitiatoriSCSIName | |-> *InitiatorAlias | |-> *DefaultiSCSIName (Read-Only) |-> InitiatorDefaultLoginOptions

Page 24: PRIMERGY BX600 10GbE LAN I/O Module (PCIe) - Fujitsumanuals.ts.fujitsu.com/file/8372/bx-10gbe-sm-clp-ref-win08.pdf · PRIMERGY BX600 10GbE LAN I/O Module ... Microsoft Windows Server

| |-> *InitialR2T (Read-Only) | |-> *ImmediateData (Read-Only) | |-> *MaxConnections (Read-Only) | |-> *MaxOutstandingR2T (Read-Only) | |-> *FirstBurstLength (Read-Only) | |-> *MaxBurstLength (Read-Only) | |-> *DefaultTime2Wait (Read-Only) | |-> *DefaultTime2Retain (Read-Only) | |-> *ErrorRecoveryLevel (Read-Only) | |-> *DataPDUInOrder (Read-Only) | |-> *DataSequenceInOrder (Read-Only) | |-> *HeaderDigest (Read-Only) | |-> *DataDigest (Read-Only) | |-> *MaxRecvDataSegmentLength (Read-Only) | |-> *TCPWindowSize (Read-Only) |-> InitiatorLoginOptions | |-> *InitialR2T | |-> *ImmediateData | |-> *HeaderDigest | |-> *DataDigest | |-> Authentication | |-> *AuthenticationMethod | |-> *InitiatorCHAPName | |-> *InitiatorSecret | |-> *TargetCHAPName | |-> *TargetSecret |-> QoS | |-> *MaxBytesPerSecond | |-> *MaxIosPerSecond |-> iSCSIStatistics | |-> *NodeRoles (Read-Only) | |-> *PortalCount (Read-Only) | |-> *NodeCount (Read-Only) | |-> *SessionCount (Read-Only) | |-> *SessionFailureCount (Read-Only) | |-> *LastSessionFailureType (Read-Only) | |-> *LastSessionRmtNodeName (Read-Only) | |-> *SessionDigestErrors (Read-Only) | |-> *SessionConnectionTimeout (Read-Only) | |-> *SessionFormatErrors (Read-Only) | |-> *LoginFailures (Read-Only) | |-> *LastFailureTime (Read-Only) | |-> *LastFailureType (Read-Only) | |-> *LastTgtFailureName (Read-Only) | |-> *LastTgtFailureAddr (Read-Only) | |-> *LoginAcceptRsps (Read-Only) | |-> *LoginOtherFailRsps (Read-Only) | |-> *LoginRedirectRsps (Read-Only) | |-> *LoginAuthFailRsps (Read-Only) | |-> *LoginAuthFails (Read-Only) | |-> *LoginNegoFails (Read-Only) | |-> *LogoutNormals (Read-Only) | |-> *LogoutOthers (Read-Only) | |-> *PortRowStatus (Read-Only) | |-> *PortalRole (Read-Only) | |-> *PortalProtocol (Read-Only) | |-> *PortalTag (Read-Only) |-> Target[0-63] | |-> TargetPortal[0-63] | | |-> *TargetIPAddress (Read-Only) | | |-> *TargetPortNumber (Read-Only) | | |-> *PortalGroupTag (Read-Only) | | |-> *Persistent

Page 25: PRIMERGY BX600 10GbE LAN I/O Module (PCIe) - Fujitsumanuals.ts.fujitsu.com/file/8372/bx-10gbe-sm-clp-ref-win08.pdf · PRIMERGY BX600 10GbE LAN I/O Module ... Microsoft Windows Server

| |-> TargetLoginOptions | | |-> *InitialR2T | | |-> *ImmediateData | | |-> *HeaderDigest | | |-> *DataDigest | | |-> Authentication | | |-> *AuthenticationMethod | | |-> *InitiatorCHAPName | | |-> *InitiatorSecret | | |-> *TargetCHAPName | | |-> *TargetSecret | |-> Session[0-63] | | |-> SessionNegotiatedLoginOptions | | | |-> *InitialR2T (Read-Only) | | | |-> *ImmediateData (Read-Only) | | | |-> *MaxConnections (Read-Only) | | | |-> *MaxOutstandingR2T (Read-Only) | | | |-> *FirstBurstLength (Read-Only) | | | |-> *MaxBurstLength (Read-Only) | | | |-> *DefaultTime2Wait (Read-Only) | | | |-> *DefaultTime2Retain (Read-Only) | | | |-> *ErrorRecoveryLevel (Read-Only) | | | |-> *DataPDUInOrder (Read-Only) | | | |-> *DataSequenceInOrder (Read-Only) | | |-> iSCSISessionStatistics | | | |-> *SessionDirection (Read-Only) | | | |-> *CmdPdus (Read-Only) | | | |-> *RspPdus (Read-Only) | | | |-> *TxDataOctetsHigh (Read-Only) | | | |-> *RxDataOctetsHigh (Read-Only) | | | |-> *DigestErrors (Read-Only) | | | |-> *CxnTimeoutErrors (Read-Only) | | | |-> *SessionTargetAlias (Read-Only) | | |-> Connection[0-3] | | | |-> ConnectionNegotiatedLoginOptions | | | | |-> *AuthenticationMethod (Read-Only) | | | | |-> *HeaderDigest (Read-Only) | | | | |-> *DataDigest (Read-Only) | | | | |-> *MaxRecvDataSegmentLength (Read-Only) | | | | |-> *TCPWindowSize (Read-Only) | | | | |-> *TCPMSS (Read-Only) | | | |-> *iSCSIConnectionID (Read-Only) | | | |-> *Status (Read-Only) | | | |-> *SourcePortNumber (Read-Only) | | | |-> *DestinationPortNumber (Read-Only) | | | |-> *SourceIPAddress (Read-Only) | | | |-> *DestinationIPAddress (Read-Only) | | | |-> *RedirectedDestinationPort (Read-Only) | | | |-> *RedirectedDestinationIPAddress (Read-Only) | | |-> *SessionTSIH (Read-Only) | | |-> *ISIDQualifier (Read-Only) | | |-> *SessionInitiatorName (Read-Only) | | |-> *SessionStatus (Read-Only) | | |-> *iSCSIBoot (Read-Only) | | |-> *Persistent (Read-Only) | |-> LUN[0-511] | | |-> *LUNNumber (Read-Only) | | |-> *LUNSize (Read-Only) | | |-> *DeviceVendorName (Read-Only)

Page 26: PRIMERGY BX600 10GbE LAN I/O Module (PCIe) - Fujitsumanuals.ts.fujitsu.com/file/8372/bx-10gbe-sm-clp-ref-win08.pdf · PRIMERGY BX600 10GbE LAN I/O Module ... Microsoft Windows Server

| | |-> *DeviceModelNumber (Read-Only) | | |-> *LUNName (Read-Only) (for ESX) | | |-> *LUNSerialNumber (Read-Only) | | |-> !OEMSETestUnitReady ( ) | | |-> !OEMSEStdInquiry ( ) | | |-> !OEMSEReadCapacity ( ) | | |-> !OEMSESCSIRead ( StartBlockAddress Count ) | | |-> !OEMSESCSIWrite ( StartBlockAddress Count ) | |-> *TargetISCSIName (Read-Only) | |-> *TargetAlias (Read-Only) | |-> *ETO (for ESX) | |-> *ETO (for WINDOWS) | |-> *ETO (for SOLARIS) | |-> !OEMSELogin ( [IPAddress] [PortNumber] [SessionInitiatorName] [ISID] ) | |-> !OEMSELogout ( [InstanceNumber] ) | |-> !OEMSEReScanLUNS ( ) |-> Discovery | |-> SendTargetPortal[0-9] | | |-> SendTargetPortalLoginOptions | | | |-> *InitialR2T | | | |-> *ImmediateData | | | |-> *HeaderDigest | | | |-> *DataDigest | | | |-> Authentication | | | |-> *InitiatorCHAPName | | | |-> *InitiatorSecret | | | |-> *TargetCHAPName | | | |-> *TargetSecret | | | |-> *AuthenticationMethod | | |-> *IPAddress (Read-Only) | | |-> *PortNumber (Read-Only) | | |-> *PortMacAddress (Read-Only) | | |-> *Persistent | | |-> !OEMSEDiscoverTargets ( ) | |-> !OEMSEAddSendTargetPortal ( IPAddress PortNumber ) | |-> !OEMSEDeleteSendTargetPortal ( InstanceNumber ) | |-> !OEMSERefreshAvailableTargets ( ) |-> !OEMSEAddTarget ( TargetName IPAddress PortNumber ) |-> !OEMSEDeleteTarget ( InstanceNumber )

5.2. OEMSEUpgradeFlashROM

Command

OEMSEUpgradeFlashROM

Description

This command updates the BladeEngine firmware version stored in non-volatile memory. You must restart the system for the updated firmware to become the active firmware version on the BladeEngine controller. Example: OEMSEUpgradeFlashROM -OEMSEparams UFIFileName="flash.ufi".

Syntax

OEMSEUpgradeFlashROM [common_options] -OEMSEparams UFIFileName="< value >" [SM-CLP-target]

Options

Page 27: PRIMERGY BX600 10GbE LAN I/O Module (PCIe) - Fujitsumanuals.ts.fujitsu.com/file/8372/bx-10gbe-sm-clp-ref-win08.pdf · PRIMERGY BX600 10GbE LAN I/O Module ... Microsoft Windows Server

[common_options]

Parameter Description

SM-CLP-target Optional input that indicates the SM-CLP target group for the given command. This overrides the current group. ".." indcates parent group. "/" indicates root group.

-OEMSEParams

takes in additional parameters as arguments as listed below in the Parameters table of this section. The parameters has to be entered in a key=value format.

Required Parameters

Parameter Name

Data Type

Min Max Default Description

UFIFileName string N/A N/A 3

This parameter specifies the path to the UFI file that will be used to upgrade the BladeEngine firmware. Minimum length of the string is 3 and maximum length of the string is 255.

Optional Parameters

None

Possible Error Messages

Common Error Messages Cannot open the specified file Invalid UFI file format BladeEngine firmware has been updated. Please reboot your system for the changes to take effect.

5.3. OEMSERefreshEventLog

Command

OEMSERefreshEventLog

Description

This command retrieves the current event log entries from the BladeEngine firmware.

Syntax

OEMSERefreshEventLog [common_options] [SM-CLP-target]

Options

[common_options]

Parameter Description SM-CLP-target

Optional input that indicates the SM-CLP target group for the given command. This overrides the current group. ".." indcates parent group. "/" indicates root group.

Required Parameters

None

Optional Parameters

Page 28: PRIMERGY BX600 10GbE LAN I/O Module (PCIe) - Fujitsumanuals.ts.fujitsu.com/file/8372/bx-10gbe-sm-clp-ref-win08.pdf · PRIMERGY BX600 10GbE LAN I/O Module ... Microsoft Windows Server

None

Possible Error Messages

Common Error Messages Memory allocation failed

5.4. OEMSEClearEventLog

Command

OEMSEClearEventLog

Description

This command clears the event log entries stored in the BladeEngine firmware. All entries will be discarded and will not be available to view via SM-CLP.

Syntax

OEMSEClearEventLog [common_options] [SM-CLP-target]

Options

[common_options]

Parameter Description SM-CLP-target

Optional input that indicates the SM-CLP target group for the given command. This overrides the current group. ".." indcates parent group. "/" indicates root group.

Required Parameters

None

Optional Parameters

None

Possible Error Messages

Common Error Messages Memory allocation failed

5.5. OEMSEConfigureIPAddress

Command

OEMSEConfigureIPAddress

Description

This command is used to manually configure the IPAddress. Specify the mandatory options of the IPAddress and the SubnetMask to be configured for the Port. Example: OEMSEConfigureIPAddress -OEMSEparams IPAddress="172.20.14.1",SubnetMask="255.255.255.0". The command will fail if DHCP is

Page 29: PRIMERGY BX600 10GbE LAN I/O Module (PCIe) - Fujitsumanuals.ts.fujitsu.com/file/8372/bx-10gbe-sm-clp-ref-win08.pdf · PRIMERGY BX600 10GbE LAN I/O Module ... Microsoft Windows Server

enabled. To disable DHCP, use the OEMSEConfigureDHCP command with a mandatory parameter and value of EnableDHCP="False".

Syntax

OEMSEConfigureIPAddress [common_options] -OEMSEparams IPAddress="< value >",SubnetMask="< value >",[Gateway="< value >"],[VLANID="< value >"] [SM-CLP-target]

Options

[common_options]

Parameter Description

SM-CLP-target Optional input that indicates the SM-CLP target group for the given command. This overrides the current group. ".." indcates parent group. "/" indicates root group.

-OEMSEParams

takes in additional parameters as arguments as listed below in the Parameters table of this section. The parameters has to be entered in a key=value format.

Required Parameters

Parameter Name

Data Type Min Max Default Description

IPAddress ipaddress 0 0 0.0.0.0 This parameter specifies the IP address to be configured for the port.

SubnetMask subnetmask 0 255 255.255.255.0This parameter specifies the Subnet mask to be configured for the port.

Optional Parameters

Parameter Name

Data Type

Min Max Default Description

Gateway ipaddress 0 0 0.0.0.0 This parameter specifies the Default Gateway to be configured for the port.

VLANID integer 0 4095 0 This parameter specifies the VLANID to be configured for the port.

Possible Error Messages

Common Error Messages Invalid value Failed to configure IP address as DHCP is Enabled. Please disable DHCP to configure IP address The IP address settings for the BladeEngine iSCSI initiator can not be modified when there is an active iSCSI boot session. Please use the iSCSISelect configuration utility to modify the IP address settings. No configuration changes were made to the BladeEngine iSCSI initiator. Warning: An active boot session is present. TCP/IP configuration changes will take effect after next reboot. The IP address settings match the existing configuration. No changes have been made to the configuration.

5.6. OEMSEConfigureDHCP

Command

OEMSEConfigureDHCP

Description

Page 30: PRIMERGY BX600 10GbE LAN I/O Module (PCIe) - Fujitsumanuals.ts.fujitsu.com/file/8372/bx-10gbe-sm-clp-ref-win08.pdf · PRIMERGY BX600 10GbE LAN I/O Module ... Microsoft Windows Server

This command is used to enable or disable DHCP. Use the mandatory parameter EnableDHCP and specify the value True to enable DHCP or False to disable DHCP. Example: OEMSEConfigureDHCP -OEMSEparams EnableDHCP="True". When enabled, the command will obtain a new IPAddress, Subnetmask and Default Gateway. When disabled, the IPAddress, Subnetmask and Default Gateway are reset to all zeros. After disabling DHCP, the IPAddress can be manually configured using the OEMSEConfigureIPAddress command.

Syntax

OEMSEConfigureDHCP [common_options] -OEMSEparams EnableDHCP="< value >" [SM-CLP-target]

Options

[common_options]

Parameter Description

SM-CLP-target Optional input that indicates the SM-CLP target group for the given command. This overrides the current group. ".." indcates parent group. "/" indicates root group.

-OEMSEParams

takes in additional parameters as arguments as listed below in the Parameters table of this section. The parameters has to be entered in a key=value format.

Required Parameters

Parameter Name

Data Type

Min Max Default Description

EnableDHCP list N/A N/A False This is the mandatory parameter to configure DHCP settings. Specify the value True to enable DHCP or False to disable DHCP. Valid values are - True,False.

Optional Parameters

None

Possible Error Messages

Common Error Messages The IP address settings for the BladeEngine iSCSI initiator can not be modified when there is an active iSCSI boot session. Please use the iSCSISelect configuration utility to modify the IP address settings. No configuration changes were made to the BladeEngine iSCSI initiator. DHCP will be enabled after the next reboot. The DHCP settings match the existing configure. No changes have been made to the configuration.

5.7. OEMSERefreshNICConfig

Command

OEMSERefreshNICConfig

Description

This command displays the current NIC configuration properties.

Syntax

Page 31: PRIMERGY BX600 10GbE LAN I/O Module (PCIe) - Fujitsumanuals.ts.fujitsu.com/file/8372/bx-10gbe-sm-clp-ref-win08.pdf · PRIMERGY BX600 10GbE LAN I/O Module ... Microsoft Windows Server

OEMSERefreshNICConfig [common_options] [SM-CLP-target]

Options

[common_options]

Parameter Description SM-CLP-target

Optional input that indicates the SM-CLP target group for the given command. This overrides the current group. ".." indcates parent group. "/" indicates root group.

Required Parameters

None

Optional Parameters

None

Possible Error Messages

Common Error Messages

5.8. OEMSEAddRouteTableEntry

Command

OEMSEAddRouteTableEntry

Description

This command adds a user specified entry to the BladeEngine iSCSI initiator route table. Specify an IPAddress, Subnet mask, and Gateway address as required parameters. Example: OEMSEAddRouteTableEntry -OEMSEparams IPAddress="10.12.0.1",SubnetMask="255.255.255.0",Gateway="10.12.2.62".

Syntax

OEMSEAddRouteTableEntry [common_options] -OEMSEparams IPAddress="< value >",SubnetMask="< value >",Gateway="< value >" [SM-CLP-target]

Options

[common_options]

Parameter Description

SM-CLP-target Optional input that indicates the SM-CLP target group for the given command. This overrides the current group. ".." indcates parent group. "/" indicates root group.

-OEMSEParams

takes in additional parameters as arguments as listed below in the Parameters table of this section. The parameters has to be entered in a key=value format.

Required Parameters

Parameter Name

Data Type Min Max Default Description

IPAddress ipaddress 0 16 0.0.0.0 This parameter specifies the IP address of the entry to be entered in the route table.

SubnetMask subnetmask 0 255 255.255.255.0 This parameter specifies the Subnet mask

Page 32: PRIMERGY BX600 10GbE LAN I/O Module (PCIe) - Fujitsumanuals.ts.fujitsu.com/file/8372/bx-10gbe-sm-clp-ref-win08.pdf · PRIMERGY BX600 10GbE LAN I/O Module ... Microsoft Windows Server

of the entry to be entered in the route table.

Gateway ipaddress 1 64 1 This parameter specifies the Gateway address of the entry to be entered in the route table.

Optional Parameters

None

Possible Error Messages

Common Error Messages Invalid value

5.9. OEMSEDeleteRouteTableEntry

Command

OEMSEDeleteRouteTableEntry

Description

This command deletes entries from the route table of the BladeEngine iSCSI initiator. The command can delete all entries in the route table or a specific entry. Specify the entry number to be deleted or enter an asterisk (*) to delete all entries. Example: OEMSEDeleteRouteTableEntry -OEMparams InstanceNumber="5".

Syntax

OEMSEDeleteRouteTableEntry [common_options] -OEMSEparams InstanceNumber="< value >" [SM-CLP-target]

Options

[common_options]

Parameter Description

SM-CLP-target Optional input that indicates the SM-CLP target group for the given command. This overrides the current group. ".." indcates parent group. "/" indicates root group.

-OEMSEParams

takes in additional parameters as arguments as listed below in the Parameters table of this section. The parameters has to be entered in a key=value format.

Required Parameters

Parameter Name

Data Type

Min Max Default Description

InstanceNumber string N/A N/A 0

This parameter specifies the number of the route table entry to be deleted. To delete all entries from the route table, use an asterisk (*) in place of a route table entry number. Minimum length of the string is 0 and maximum length of the string is 15.

Optional Parameters

None

Possible Error Messages

Page 33: PRIMERGY BX600 10GbE LAN I/O Module (PCIe) - Fujitsumanuals.ts.fujitsu.com/file/8372/bx-10gbe-sm-clp-ref-win08.pdf · PRIMERGY BX600 10GbE LAN I/O Module ... Microsoft Windows Server

Common Error Messages

5.10. OEMSERefreshRouteTableEntry

Command

OEMSERefreshRouteTableEntry

Description

This command retrieves the current route table entries from the BladeEngine firmware.

Syntax

OEMSERefreshRouteTableEntry [common_options] [SM-CLP-target]

Options

[common_options]

Parameter Description SM-CLP-target

Optional input that indicates the SM-CLP target group for the given command. This overrides the current group. ".." indcates parent group. "/" indicates root group.

Required Parameters

None

Optional Parameters

None

Possible Error Messages

Common Error Messages

5.11. OEMSEAddARPTableEntry

Command

OEMSEAddARPTableEntry

Description

This command will add an entry into the ARP table of the BladeEngine iSCSI initiator.

Syntax

OEMSEAddARPTableEntry [common_options] -OEMSEparams IPAddress="< value >",MACAddress="< value >" [SM-CLP-target]

Options

[common_options]

Page 34: PRIMERGY BX600 10GbE LAN I/O Module (PCIe) - Fujitsumanuals.ts.fujitsu.com/file/8372/bx-10gbe-sm-clp-ref-win08.pdf · PRIMERGY BX600 10GbE LAN I/O Module ... Microsoft Windows Server

Parameter Description

SM-CLP-target Optional input that indicates the SM-CLP target group for the given command. This overrides the current group. ".." indcates parent group. "/" indicates root group.

-OEMSEParams

takes in additional parameters as arguments as listed below in the Parameters table of this section. The parameters has to be entered in a key=value format.

Required Parameters

Parameter Name

Data Type

Min Max Default Description

IPAddress ipaddress 0 16 0.0.0.0 This parameter specifies the IP address of the entry to be added to the ARP table.

MACAddress string N/A N/A 00-00-00-00-00-00

This parameter specifies the MAC address of the entry to be added to the ARP table. Minimum length of the string is 17 and maximum length of the string is 17.

Optional Parameters

None

Possible Error Messages

Common Error Messages Invalid value

5.12. OEMSEDeleteARPTableEntry

Command

OEMSEDeleteARPTableEntry

Description

This command will delete the given ARP table entry.

Syntax

OEMSEDeleteARPTableEntry [common_options] -OEMSEparams InstanceNumber="< value >" [SM-CLP-target]

Options

[common_options]

Parameter Description

SM-CLP-target Optional input that indicates the SM-CLP target group for the given command. This overrides the current group. ".." indcates parent group. "/" indicates root group.

-OEMSEParams

takes in additional parameters as arguments as listed below in the Parameters table of this section. The parameters has to be entered in a key=value format.

Required Parameters

Parameter Name

Data Type

Min Max Default Description

InstanceNumber string N/A N/A 0 This parameter accepts string input and converts it to an equivalent number and uses that as an instance number. Use an asterisk '*' in place of an instance

Page 35: PRIMERGY BX600 10GbE LAN I/O Module (PCIe) - Fujitsumanuals.ts.fujitsu.com/file/8372/bx-10gbe-sm-clp-ref-win08.pdf · PRIMERGY BX600 10GbE LAN I/O Module ... Microsoft Windows Server

number to indicate all instances. Minimum length of the string is 0 and maximum length of the string is 63.

Optional Parameters

None

Possible Error Messages

Common Error Messages

5.13. OEMSERefreshARPTableEntry

Command

OEMSERefreshARPTableEntry

Description

This command retrieves the current ARP table entries from the BladeEngine firmware.

Syntax

OEMSERefreshARPTableEntry [common_options] [SM-CLP-target]

Options

[common_options]

Parameter Description SM-CLP-target

Optional input that indicates the SM-CLP target group for the given command. This overrides the current group. ".." indcates parent group. "/" indicates root group.

Required Parameters

None

Optional Parameters

None

Possible Error Messages

Common Error Messages

5.14. OEMSEPing

Command

OEMSEPing

Description

This command will send an ICMP ping request to the specified IPv4 address.

Page 36: PRIMERGY BX600 10GbE LAN I/O Module (PCIe) - Fujitsumanuals.ts.fujitsu.com/file/8372/bx-10gbe-sm-clp-ref-win08.pdf · PRIMERGY BX600 10GbE LAN I/O Module ... Microsoft Windows Server

Syntax

OEMSEPing [common_options] -OEMSEparams IPAddress="< value >" [SM-CLP-target]

Options

[common_options]

Parameter Description

SM-CLP-target Optional input that indicates the SM-CLP target group for the given command. This overrides the current group. ".." indcates parent group. "/" indicates root group.

-OEMSEParams

takes in additional parameters as arguments as listed below in the Parameters table of this section. The parameters has to be entered in a key=value format.

Required Parameters

Parameter Name

Data Type

Min Max Default Description

IPAddress ipaddress 0 0 0.0.0.0 This parameter specifies the IPv4 address to which the ICMP ping request will be sent.

Optional Parameters

None

Possible Error Messages

Common Error Messages Invalid value

5.15. OEMSEDiscoveryiSNSThruDHCP

Command

OEMSEDiscoveryiSNSThruDHCP

Description

This command discovers any iSNS Servers through DHCP and adds iSNS entries (if any) to the target.

Syntax

OEMSEDiscoveryiSNSThruDHCP [common_options] [SM-CLP-target]

Options

[common_options]

Parameter Description SM-CLP-target

Optional input that indicates the SM-CLP target group for the given command. This overrides the current group. ".." indcates parent group. "/" indicates root group.

Required Parameters

None

Page 37: PRIMERGY BX600 10GbE LAN I/O Module (PCIe) - Fujitsumanuals.ts.fujitsu.com/file/8372/bx-10gbe-sm-clp-ref-win08.pdf · PRIMERGY BX600 10GbE LAN I/O Module ... Microsoft Windows Server

Optional Parameters

None

Possible Error Messages

Common Error Messages

5.16. OEMSEAddiSNSServer

Command

OEMSEAddiSNSServer

Description

This command adds the given iSNS server to the BladeEngine controller. Specify the iSNS server IP address as the first required option and the port number as the second. This command will return a successful message if communication with the specified iSNS server is completed. If not successful, check your network configuration. Example: OEMSEAddiSNSServer -OEMSEparams IPAddress="172.40.2.1",PortNum="3205".

Syntax

OEMSEAddiSNSServer [common_options] -OEMSEparams IPAddress="< value >",PortNum="< value >" [SM-CLP-target]

Options

[common_options]

Parameter Description

SM-CLP-target Optional input that indicates the SM-CLP target group for the given command. This overrides the current group. ".." indcates parent group. "/" indicates root group.

-OEMSEParams

takes in additional parameters as arguments as listed below in the Parameters table of this section. The parameters has to be entered in a key=value format.

Required Parameters

Parameter Name

Data Type

Min Max Default Description

IPAddress ipaddress 0 0 0.0.0.0

This parameter specifies the IP address of the server to be added into the table. The iSNS server table will be used by the firmware for discovering targets.

PortNum integer 1024 65535 1024 This parameter specifies the port number of the iSNS server.

Optional Parameters

None

Possible Error Messages

Common Error Messages

5.17. OEMSEDeleteiSNSServer

Page 38: PRIMERGY BX600 10GbE LAN I/O Module (PCIe) - Fujitsumanuals.ts.fujitsu.com/file/8372/bx-10gbe-sm-clp-ref-win08.pdf · PRIMERGY BX600 10GbE LAN I/O Module ... Microsoft Windows Server

Command

OEMSEDeleteiSNSServer

Description

This command deletes the iSNS server entry to the BladeEngine controller specified as the argument. Specify * to delete all the iSNS server entries from the BladeEngine controller. Example: OEMSEDeleteiSNSServer -OEMSEparams InstanceNumber="1".

Syntax

OEMSEDeleteiSNSServer [common_options] -OEMSEparams InstanceNumber="< value >" [SM-CLP-target]

Options

[common_options]

Parameter Description

SM-CLP-target Optional input that indicates the SM-CLP target group for the given command. This overrides the current group. ".." indcates parent group. "/" indicates root group.

-OEMSEParams

takes in additional parameters as arguments as listed below in the Parameters table of this section. The parameters has to be entered in a key=value format.

Required Parameters

Parameter Name

Data Type

Min Max Default Description

InstanceNumber string N/A N/A 0

This parameter accepts string input and converts it to equivalent number and use that as instance number. Specify an asterisk '*' instead of an instance number to indicate all instances. Minimum length of the string is 0 and maximum length of the string is 3.

Optional Parameters

None

Possible Error Messages

Common Error Messages

5.18. OEMSEEraseConfiguration

Command

OEMSEEraseConfiguration

Description

This command resets the BladeEngine configuration to factory default settings. Upon successful completion of this command, all user configured settings are lost. No reboot is required for these changes to take effect.

Syntax

Page 39: PRIMERGY BX600 10GbE LAN I/O Module (PCIe) - Fujitsumanuals.ts.fujitsu.com/file/8372/bx-10gbe-sm-clp-ref-win08.pdf · PRIMERGY BX600 10GbE LAN I/O Module ... Microsoft Windows Server

OEMSEEraseConfiguration [common_options] [-OEMSEparams] [LogicalHBAInstanceNumber="< value >"] [SM-CLP-target]

Options

[common_options]

Parameter Description

SM-CLP-target Optional input that indicates the SM-CLP target group for the given command. This overrides the current group. ".." indcates parent group. "/" indicates root group.

-OEMSEParams

takes in additional parameters as arguments as listed below in the Parameters table of this section. The parameters has to be entered in a key=value format.

Required Parameters

None

Optional Parameters

Parameter Name Data Type

Min Max Default Description

LogicalHBAInstanceNumber integer 0 15 0

DomainId of the LogicalHBA of which configuration should be erased. If no value is given then, configuration is erased for all the 16 domains.

Possible Error Messages

Common Error Messages Active session(s) present. Please log out of all sessions before clearing configuration. For systems booting from an iSCSI target, configuration can only be cleared using the iSCSI Select Utility.

5.19. OEMSETestUnitReady

Command

OEMSETestUnitReady

Description

This command enables protocol validation by issuing a Test Unit Ready to the LUN instance number input by the user for the target and reporting status back to the application.

Syntax

OEMSETestUnitReady [common_options] [SM-CLP-target]

Options

[common_options]

Parameter Description SM-CLP-target

Optional input that indicates the SM-CLP target group for the given command. This overrides the current group. ".." indcates parent group. "/" indicates root group.

Required Parameters

Page 40: PRIMERGY BX600 10GbE LAN I/O Module (PCIe) - Fujitsumanuals.ts.fujitsu.com/file/8372/bx-10gbe-sm-clp-ref-win08.pdf · PRIMERGY BX600 10GbE LAN I/O Module ... Microsoft Windows Server

None

Optional Parameters

None

Possible Error Messages

Common Error Messages

5.20. OEMSEStdInquiry

Command

OEMSEStdInquiry

Description

This command is used for protocol validation by issuing Standard inquiry on the selected LUN instance and updates the VendorId and ProductId properties.

Syntax

OEMSEStdInquiry [common_options] [SM-CLP-target]

Options

[common_options]

Parameter Description SM-CLP-target

Optional input that indicates the SM-CLP target group for the given command. This overrides the current group. ".." indcates parent group. "/" indicates root group.

Required Parameters

None

Optional Parameters

None

Possible Error Messages

Common Error Messages

5.21. OEMSEReadCapacity

Command

OEMSEReadCapacity

Description

This command enables protocol validation by issuing a Read Capacity to the LUN instance number input by the user for the target and reporting the status back to the application.

Page 41: PRIMERGY BX600 10GbE LAN I/O Module (PCIe) - Fujitsumanuals.ts.fujitsu.com/file/8372/bx-10gbe-sm-clp-ref-win08.pdf · PRIMERGY BX600 10GbE LAN I/O Module ... Microsoft Windows Server

Syntax

OEMSEReadCapacity [common_options] [SM-CLP-target]

Options

[common_options]

Parameter Description SM-CLP-target

Optional input that indicates the SM-CLP target group for the given command. This overrides the current group. ".." indcates parent group. "/" indicates root group.

Required Parameters

None

Optional Parameters

None

Possible Error Messages

Common Error Messages

5.22. OEMSESCSIRead

Command

OEMSESCSIRead

Description

This command enables protocol validation by issuing SCSI READ commands to the LUN (device).

Syntax

OEMSESCSIRead [common_options] -OEMSEparams StartBlockAddress="< value >",Count="< value >" [SM-CLP-target]

Options

[common_options]

Parameter Description

SM-CLP-target Optional input that indicates the SM-CLP target group for the given command. This overrides the current group. ".." indcates parent group. "/" indicates root group.

-OEMSEParams

takes in additional parameters as arguments as listed below in the Parameters table of this section. The parameters has to be entered in a key=value format.

Required Parameters

Parameter Name Data Type

Min Max Default Description

StartBlockAddress integer 0 65535 0 This parameter indicates the first block address from where to begin the SCSI Read/Write.

Page 42: PRIMERGY BX600 10GbE LAN I/O Module (PCIe) - Fujitsumanuals.ts.fujitsu.com/file/8372/bx-10gbe-sm-clp-ref-win08.pdf · PRIMERGY BX600 10GbE LAN I/O Module ... Microsoft Windows Server

Count integer 1 65535 1 This parameter accepts count of number of blocks to be transferred to the device.

Optional Parameters

None

Possible Error Messages

Common Error Messages

5.23. OEMSESCSIWrite

Command

OEMSESCSIWrite

Description

This command enables protocol validation by issuing SCSI WRITE commands to the LUN (device).

Syntax

OEMSESCSIWrite [common_options] -OEMSEparams StartBlockAddress="< value >",Count="< value >" [SM-CLP-target]

Options

[common_options]

Parameter Description

SM-CLP-target Optional input that indicates the SM-CLP target group for the given command. This overrides the current group. ".." indcates parent group. "/" indicates root group.

-OEMSEParams

takes in additional parameters as arguments as listed below in the Parameters table of this section. The parameters has to be entered in a key=value format.

Required Parameters

Parameter Name Data Type

Min Max Default Description

StartBlockAddress integer 0 65535 0 This parameter indicates the first block address from where to begin the SCSI Read/Write.

Count integer 1 65535 1 This parameter accepts count of number of blocks to be transferred to the device.

Optional Parameters

None

Possible Error Messages

Common Error Messages

5.24. OEMSELogin

Page 43: PRIMERGY BX600 10GbE LAN I/O Module (PCIe) - Fujitsumanuals.ts.fujitsu.com/file/8372/bx-10gbe-sm-clp-ref-win08.pdf · PRIMERGY BX600 10GbE LAN I/O Module ... Microsoft Windows Server

Command

OEMSELogin

Description

This action allows the initiator to login to a target with its current set of login parameters. This action takes the following parameters: IP address of the portal, port number of the portal, Instance number of the controller (Physical HBA), and finally the instance number of the port (Logical HBA). The last 2 parameters can be defaulted to the value of the 'DefaultIntrPort' property, which tells what initiator port number to use. The first 2 parameters can be defaulted to the value of the 'DefaultLoginPortal', which tells which portal under the Target will be logged into.

Syntax

OEMSELogin [common_options] [-OEMSEparams] [IPAddress="< value >"],[PortNumber="< value >"],[SessionInitiatorName="< value >"],[ISID="< value >"] [SM-CLP-target]

Options

[common_options]

Parameter Description

SM-CLP-target Optional input that indicates the SM-CLP target group for the given command. This overrides the current group. ".." indcates parent group. "/" indicates root group.

-OEMSEParams

takes in additional parameters as arguments as listed below in the Parameters table of this section. The parameters has to be entered in a key=value format.

Required Parameters

None

Optional Parameters

Parameter Name Data Type

Min Max Default Description

IPAddress ipaddress 0 0 0.0.0.0 This parameter specifies the IP address of the target portal to login.

PortNumber integer 1024 65535 1024 This parameter specifes the port number of the target to login.

SessionInitiatorName string N/A N/A iqn.se

This parameter specifies the initiator iSCSI name for the session to login. Minimum length of the string is 1 and maximum length of the string is 224.

ISID integer 0 65535 0 This parameter indicates the ISID for the session to login.

Possible Error Messages

Common Error Messages The BladeEngine iSCSI initiator TCP/IP settings are not configured. Please configure the TCP/IP settings before issuing this command. iSCSI is not enabled for this LogicalHBA. Please, enable iSCSI before issuing this command. Setting ETO failed Target is logged-in successfully, but failed to rescan. Error

Page 44: PRIMERGY BX600 10GbE LAN I/O Module (PCIe) - Fujitsumanuals.ts.fujitsu.com/file/8372/bx-10gbe-sm-clp-ref-win08.pdf · PRIMERGY BX600 10GbE LAN I/O Module ... Microsoft Windows Server

5.25. OEMSELogout

Command

OEMSELogout

Description

This command sends a Logout request to this target. SM-CLP will not allow logout of BootSessions.

Syntax

OEMSELogout [common_options] [-OEMSEparams] [InstanceNumber="< value >"] [SM-CLP-target]

Options

[common_options]

Parameter Description

SM-CLP-target Optional input that indicates the SM-CLP target group for the given command. This overrides the current group. ".." indcates parent group. "/" indicates root group.

-OEMSEParams

takes in additional parameters as arguments as listed below in the Parameters table of this section. The parameters has to be entered in a key=value format.

Required Parameters

None

Optional Parameters

Parameter Name

Data Type

Min Max Default Description

InstanceNumber string N/A N/A 0

This parameter accepts string input and converts it to an equivalent number and uses that as an instance number. Specify an asterisk '*' instead of an instance number to indicate all instances. Minimum length of the string is 0 and maximum length of the string is 63.

Possible Error Messages

Common Error Messages

5.26. OEMSEReScanLUNS

Command

OEMSEReScanLUNS

Description

This command reports the LUNs on the system.

Syntax

Page 45: PRIMERGY BX600 10GbE LAN I/O Module (PCIe) - Fujitsumanuals.ts.fujitsu.com/file/8372/bx-10gbe-sm-clp-ref-win08.pdf · PRIMERGY BX600 10GbE LAN I/O Module ... Microsoft Windows Server

OEMSEReScanLUNS [common_options] [SM-CLP-target]

Options

[common_options]

Parameter Description SM-CLP-target

Optional input that indicates the SM-CLP target group for the given command. This overrides the current group. ".." indcates parent group. "/" indicates root group.

Required Parameters

None

Optional Parameters

None

Possible Error Messages

Common Error Messages No session available to this target

5.27. OEMSEDiscoverTargets

Command

OEMSEDiscoverTargets

Description

Use this command to initiate discovery sessions. A discovery login will be sent to the IP address and port number specified in the OEMSEAddSendTargetPortal command. If discovery is successful, the iSCSI target will return its iSCSI name, allowing login just as a manually configured target. To login to the target, issue the command OEMSELogin in the newly created Target group. This group is found in the /LogicalHBA(x)/iSCSI group.

Syntax

OEMSEDiscoverTargets [common_options] [SM-CLP-target]

Options

[common_options]

Parameter Description SM-CLP-target

Optional input that indicates the SM-CLP target group for the given command. This overrides the current group. ".." indcates parent group. "/" indicates root group.

Required Parameters

None

Optional Parameters

None

Page 46: PRIMERGY BX600 10GbE LAN I/O Module (PCIe) - Fujitsumanuals.ts.fujitsu.com/file/8372/bx-10gbe-sm-clp-ref-win08.pdf · PRIMERGY BX600 10GbE LAN I/O Module ... Microsoft Windows Server

Possible Error Messages

Common Error Messages The BladeEngine iSCSI initiator TCP/IP settings are not configured. Please configure the TCP/IP settings before issuing this command. iSCSI is not enabled for this LogicalHBA. Please, enable iSCSI before issuing this command.

5.28. OEMSEAddSendTargetPortal

Command

OEMSEAddSendTargetPortal

Description

This command creates a SendTarget Portal. The iSCSI Sendtargets mechanism is used to discover a target name using the IP address and port number of the target. Specify the IP address of the target portal as the first required option, and the target port number as the second. Example: OEMSEAddSendTargetPortal -OEMSEparams IPAddress="172.40.2.1",PortNum="3205". After the Sendtarget portal is created, cd into the newly created Sendtargetportal group and issue the command: OEMSEDiscoverTargets. This will issue the Discovery login. If successful, the target will return it's iSCSI name, allowing login just as with a manually configured target.

Syntax

OEMSEAddSendTargetPortal [common_options] -OEMSEparams IPAddress="< value >",PortNumber="< value >" [SM-CLP-target]

Options

[common_options]

Parameter Description

SM-CLP-target Optional input that indicates the SM-CLP target group for the given command. This overrides the current group. ".." indcates parent group. "/" indicates root group.

-OEMSEParams

takes in additional parameters as arguments as listed below in the Parameters table of this section. The parameters has to be entered in a key=value format.

Required Parameters

Parameter Name

Data Type

Min Max Default Description

IPAddress ipaddress 0 0 0.0.0.0 This parameter specifies the IP address of the sendtarget portal.

PortNumber integer 1024 65535 1024 This parameter specifies the Port Number of the SendTargetPortal.

Optional Parameters

None

Possible Error Messages

Common Error Messages Cannot add duplicate entries

Page 47: PRIMERGY BX600 10GbE LAN I/O Module (PCIe) - Fujitsumanuals.ts.fujitsu.com/file/8372/bx-10gbe-sm-clp-ref-win08.pdf · PRIMERGY BX600 10GbE LAN I/O Module ... Microsoft Windows Server

iSCSI is not enabled for this LogicalHBA. Please, enable iSCSI before issuing this command.

5.29. OEMSEDeleteSendTargetPortal

Command

OEMSEDeleteSendTargetPortal

Description

This command deletes the specified SendTarget Portal from the BladeEngine controller. Specify * to delete all the SendTarget Portals. Example: OEMSEDeleteSendTargetPortal -OEMSEparams InstanceNumber="3".

Syntax

OEMSEDeleteSendTargetPortal [common_options] -OEMSEparams InstanceNumber="< value >" [SM-CLP-target]

Options

[common_options]

Parameter Description

SM-CLP-target Optional input that indicates the SM-CLP target group for the given command. This overrides the current group. ".." indcates parent group. "/" indicates root group.

-OEMSEParams

takes in additional parameters as arguments as listed below in the Parameters table of this section. The parameters has to be entered in a key=value format.

Required Parameters

Parameter Name

Data Type

Min Max Default Description

InstanceNumber string N/A N/A 0

This parameter accepts string input and converts it to equivalent number and use that as instance number. Specify an asterisk '*' instead of an instance number to indicate all instances. Minimum length of the string is 0 and maximum length of the string is 9.

Optional Parameters

None

Possible Error Messages

Common Error Messages

5.30. OEMSERefreshAvailableTargets

Command

OEMSERefreshAvailableTargets

Description

Page 48: PRIMERGY BX600 10GbE LAN I/O Module (PCIe) - Fujitsumanuals.ts.fujitsu.com/file/8372/bx-10gbe-sm-clp-ref-win08.pdf · PRIMERGY BX600 10GbE LAN I/O Module ... Microsoft Windows Server

This command performs a rescan and detects any newly discovered targets. You can view the updated list of targets present by executing the show command. The target groups (if manually added or discovered) are found under the /LogicalHBA(x)/iSCSI group.

Syntax

OEMSERefreshAvailableTargets [common_options] [SM-CLP-target]

Options

[common_options]

Parameter Description SM-CLP-target

Optional input that indicates the SM-CLP target group for the given command. This overrides the current group. ".." indcates parent group. "/" indicates root group.

Required Parameters

None

Optional Parameters

None

Possible Error Messages

Common Error Messages Memory allocation failed The BladeEngine iSCSI initiator TCP/IP settings are not configured. Please configure the TCP/IP settings before issuing this command. iSCSI is not enabled for this LogicalHBA. Please, enable iSCSI before issuing this command.

5.31. OEMSEAddTarget

Command

OEMSEAddTarget

Description

This command adds a target manually to the list of targets for the initiator. Specify the iSCSI name, IP address, and port number for the target. Example: OEMSEAddTarget -OEMSEparams TargetName="iqn.2003-07.com.serverengines:tgt1",IPAddress="17.2.21.15",PortNumber="3205".

Syntax

OEMSEAddTarget [common_options] -OEMSEparams TargetName="< value >",IPAddress="< value >",PortNumber="< value >" [SM-CLP-target]

Options

[common_options]

Parameter Description SM-CLP-target Optional input that indicates the SM-CLP target group for the given command. This

Page 49: PRIMERGY BX600 10GbE LAN I/O Module (PCIe) - Fujitsumanuals.ts.fujitsu.com/file/8372/bx-10gbe-sm-clp-ref-win08.pdf · PRIMERGY BX600 10GbE LAN I/O Module ... Microsoft Windows Server

overrides the current group. ".." indcates parent group. "/" indicates root group. -OEMSEParams

takes in additional parameters as arguments as listed below in the Parameters table of this section. The parameters has to be entered in a key=value format.

Required Parameters

Parameter Name

Data Type

Min Max Default Description

TargetName string N/A N/A iqn.tgt

This parameter indicates the fully qualified iSCSI name of the target to be added. Adding this target will not login. An explicit login has to be done on this target. Minimum length of the string is 6 and maximum length of the string is 255.

IPAddress ipaddress 0 0 0.0.0.0 This parameter specifies the IP address of the target to be added.

PortNumber integer 1024 65535 1024 This parameter specifies the port number of the target to be added.

Optional Parameters

None

Possible Error Messages

Common Error Messages iSCSI is not enabled for this LogicalHBA. Please, enable iSCSI before issuing this command.

5.32. OEMSEDeleteTarget

Command

OEMSEDeleteTarget

Description

Use this command to manually delete a target from the list of targets.

Syntax

OEMSEDeleteTarget [common_options] -OEMSEparams InstanceNumber="< value >" [SM-CLP-target]

Options

[common_options]

Parameter Description

SM-CLP-target Optional input that indicates the SM-CLP target group for the given command. This overrides the current group. ".." indcates parent group. "/" indicates root group.

-OEMSEParams

takes in additional parameters as arguments as listed below in the Parameters table of this section. The parameters has to be entered in a key=value format.

Required Parameters

Parameter Name

Data Type

Min Max Default Description

InstanceNumber string N/A N/A 0 This parameter accepts string input and converts it to

Page 50: PRIMERGY BX600 10GbE LAN I/O Module (PCIe) - Fujitsumanuals.ts.fujitsu.com/file/8372/bx-10gbe-sm-clp-ref-win08.pdf · PRIMERGY BX600 10GbE LAN I/O Module ... Microsoft Windows Server

an equivalent number and uses that as an instance number. Specify an asterisk '*' instead of an instance number to indicate all instances. Minimum length of the string is 0 and maximum length of the string is 63.

Optional Parameters

None

Possible Error Messages

Common Error Messages Active sessions present

6. Appendix

6.1. MILI_Groups

This chapter contains all the groups map for Storage Blade. Each group is described in a table with a brief description and its identification name (refered to as "StringIdentifier), Attributes (access permissions), Multi-instance (yes or no) along with its adjacent groups, properties and OEMSECommands.

6.1.1. ROOT

String Identifier ROOT Group Description Root Group Attributes static MultiInstance No MaxInstance N/A Parent GroupName ROOT

Subgroups 1. BladeEngine

Properties for the group 1. MILIServiceVersion 2. MILIHierarchyVersion

OEMSECommands for the group None

Table 3: ROOT

6.1.2. BladeEngine

String Identifier BladeEngine

Group Description This group instance corresponds to a single BladeEngine controller in this host.

Attributes dynamic MultiInstance Yes MaxInstance 8 Parent GroupName ROOT

Subgroups 1. EventLog 2. iSCSIPhysicalHBA

Properties for the group

1. Manufacturer 2. ModelNumber 3. Description 4. SerialNumber 5. ActiveFirmwareVersion

Page 51: PRIMERGY BX600 10GbE LAN I/O Module (PCIe) - Fujitsumanuals.ts.fujitsu.com/file/8372/bx-10gbe-sm-clp-ref-win08.pdf · PRIMERGY BX600 10GbE LAN I/O Module ... Microsoft Windows Server

6. FirmwareVersionOnFlash 7. BIOSVersion 8. BootCodeVersion 9. FirmwareStatus 10. iSCSIVersionMin 11. iSCSIVersionMax 12. MaxCDBLength 13. MaxMTUSize 14. VLDCapable 15. VLDEnabled

OEMSECommands for the group

1. OEMSEUpgradeFlashROM

Table 4: BladeEngine

6.1.3. EventLog

String Identifier EventLog

Group Description This group contains the BladeEngine firmware event log entries and actions.

Attributes static MultiInstance No MaxInstance N/A Parent GroupName BladeEngine

Subgroups 1. EventLogEntry

Properties for the group None

OEMSECommands for the group

1. OEMSERefreshEventLog 2. OEMSEClearEventLog

Table 5: EventLog

6.1.4. EventLogEntry

String Identifier EventLogEntry

Group Description This group represents an event log entry from the BladeEngine firmware.

Attributes dynamic MultiInstance Yes MaxInstance 1024 Parent GroupName EventLog Subgroups None

Properties for the group

1. SequenceNumber 2. TimeStamp 3. Severity 4. Description 5. ErrorCode

OEMSECommands for the group

None

Table 6: EventLogEntry

6.1.5. NICPhysicalHBA

String Identifier NICPhysicalHBA

Page 52: PRIMERGY BX600 10GbE LAN I/O Module (PCIe) - Fujitsumanuals.ts.fujitsu.com/file/8372/bx-10gbe-sm-clp-ref-win08.pdf · PRIMERGY BX600 10GbE LAN I/O Module ... Microsoft Windows Server

Group Description This group represents the Physical HBA group that contains the properties of the NIC interface for this domain of the BladeEngine controller. It allows the user to create virtual interfaces and configure the NIC QoS parameters.

Attributes dynamic MultiInstance Yes MaxInstance 8 Parent GroupName BladeEngine Subgroups None Properties for the group

None

OEMSECommands for the group

None

Table 7: NICPhysicalHBA

6.1.6. PCI

String Identifier PCI

Group Description This group contains the PCI properties of the BladeEngine controller.

Attributes static MultiInstance No MaxInstance N/A Parent GroupName NICPhysicalHBA Subgroups None Properties for the group None OEMSECommands for the group

None

Table 8: PCI

6.1.7. Driver

String Identifier Driver

Group Description This group corresponds to information about the iSCSI initiator driver.

Attributes static MultiInstance No MaxInstance N/A Parent GroupName NICPhysicalHBA Subgroups None Properties for the group None OEMSECommands for the group

None

Table 9: Driver

6.1.8. LogicalHBA

String Identifier LogicalHBA Group Description This group instance corresponds to a virtual NIC interface. Attributes dynamic MultiInstance Yes MaxInstance 16 Parent GroupName NICPhysicalHBA Subgroups None Properties for the group None OEMSECommands for the group None

Page 53: PRIMERGY BX600 10GbE LAN I/O Module (PCIe) - Fujitsumanuals.ts.fujitsu.com/file/8372/bx-10gbe-sm-clp-ref-win08.pdf · PRIMERGY BX600 10GbE LAN I/O Module ... Microsoft Windows Server

Table 10: LogicalHBA

6.1.9. QoS

String Identifier QoS Group Description This group contains the properties of Qos. Attributes static MultiInstance No MaxInstance N/A Parent GroupName LogicalHBA Subgroups None Properties for the group None OEMSECommands for the group None

Table 11: QoS

6.1.10. iSCSIPhysicalHBA

String Identifier iSCSIPhysicalHBA

Group Description This group represents properties of the BladeEngine controller instance under this domain.

Attributes dynamic MultiInstance Yes MaxInstance 8 Parent GroupName BladeEngine

Subgroups

1. Driver 2. Network 3. PCI 4. iSNS 5. LogicalHBA

Properties for the group None

OEMSECommands for the group

1. OEMSEEraseConfiguration

Table 12: iSCSIPhysicalHBA

6.1.11. Driver

String Identifier Driver

Group Description This group contains information about the host operating system's BladeEngine iSCSI initiator driver.

Attributes static MultiInstance No MaxInstance N/A Parent GroupName iSCSIPhysicalHBA Subgroups None

Properties for the group 1. DriverName 2. DriverVersion

OEMSECommands for the group

None

Table 13: Driver

6.1.12. Network

Page 54: PRIMERGY BX600 10GbE LAN I/O Module (PCIe) - Fujitsumanuals.ts.fujitsu.com/file/8372/bx-10gbe-sm-clp-ref-win08.pdf · PRIMERGY BX600 10GbE LAN I/O Module ... Microsoft Windows Server

String Identifier Network

Group Description This group consists of the TCP/NIC configuration of the Network Port.

Attributes static MultiInstance No MaxInstance N/A Parent GroupName iSCSIPhysicalHBA

Subgroups

1. DHCP 2. TCPIPConfiguration 3. NICConfiguration 4. RouteTable 5. ARPTable

Properties for the group None

OEMSECommands for the group

1. OEMSEPing

Table 14: Network

6.1.13. DHCP

String Identifier DHCP Group Description This group contains the DHCP settings and related actions. Attributes static MultiInstance No MaxInstance N/A Parent GroupName Network Subgroups None

Properties for the group 1. DHCPServerAvailable 2. DHCPObtainNewIPAddress

OEMSECommands for the group None

Table 15: DHCP

6.1.14. TCPIPConfiguration

String Identifier TCPIPConfiguration Group Description This group consists of the TCP configuration of the Network port. Attributes static MultiInstance No MaxInstance N/A Parent GroupName Network Subgroups None

Properties for the group

1. DHCPEnabled 2. InitiatorIPAddress 3. InitiatorSubnetMask 4. DefaultGateway 5. IPVersionSupported 6. VLANID

OEMSECommands for the group 1. OEMSEConfigureIPAddress 2. OEMSEConfigureDHCP

Table 16: TCPIPConfiguration

6.1.15. NICConfiguration

Page 55: PRIMERGY BX600 10GbE LAN I/O Module (PCIe) - Fujitsumanuals.ts.fujitsu.com/file/8372/bx-10gbe-sm-clp-ref-win08.pdf · PRIMERGY BX600 10GbE LAN I/O Module ... Microsoft Windows Server

String Identifier NICConfiguration Group Description This group consists of the NIC configuration of the Network port. Attributes static MultiInstance No MaxInstance N/A Parent GroupName Network Subgroups None

Properties for the group

1. PortSpeed 2. PortMaxSpeed 3. MaxFrameSize 4. LinkStatus 5. ActivePort 6. MACAddress

OEMSECommands for the group 1. OEMSERefreshNICConfig

Table 17: NICConfiguration

6.1.16. RouteTable

String Identifier RouteTable

Group Description This group contains the route table entries for the BladeEngine iSCSI initiator firmware.

Attributes static MultiInstance No MaxInstance N/A Parent GroupName Network

Subgroups 1. RouteTableEntry

Properties for the group None

OEMSECommands for the group

1. OEMSEAddRouteTableEntry 2. OEMSEDeleteRouteTableEntry 3. OEMSERefreshRouteTableEntry

Table 18: RouteTable

6.1.17. RouteTableEntry

String Identifier RouteTableEntry

Group Description This group represents a route table entry in the BladeEngine iSCSI initiator firmware.

Attributes dynamic MultiInstance Yes MaxInstance 16 Parent GroupName RouteTable Subgroups None

Properties for the group

1. IPAddress 2. SubnetMask 3. Gateway

OEMSECommands for the group

None

Table 19: RouteTableEntry

6.1.18. ARPTable

Page 56: PRIMERGY BX600 10GbE LAN I/O Module (PCIe) - Fujitsumanuals.ts.fujitsu.com/file/8372/bx-10gbe-sm-clp-ref-win08.pdf · PRIMERGY BX600 10GbE LAN I/O Module ... Microsoft Windows Server

String Identifier ARPTable

Group Description This group contains the ARP table entries for the BladeEngine iSCSI initiator firmware.

Attributes static MultiInstance No MaxInstance N/A Parent GroupName Network

Subgroups 1. ARPTableEntry

Properties for the group None

OEMSECommands for the group

1. OEMSEAddARPTableEntry 2. OEMSEDeleteARPTableEntry 3. OEMSERefreshARPTableEntry

Table 20: ARPTable

6.1.19. ARPTableEntry

String Identifier ARPTableEntry

Group Description This group instance corresponds to a ARP Table Entry for the BladeEngine iSCSI initiator firmware.

Attributes dynamic MultiInstance Yes MaxInstance 64 Parent GroupName ARPTable Subgroups None

Properties for the group 1. IPAddress 2. MACAddress

OEMSECommands for the group

None

Table 21: ARPTableEntry

6.1.20. PCI

String Identifier PCI

Group Description This group contains the PCI properties for the BladeEngine controller.

Attributes static MultiInstance No MaxInstance N/A Parent GroupName iSCSIPhysicalHBA Subgroups None

Properties for the group

1. VendorID 2. DeviceID 3. SubsysDeviceID 4. SubsysVendorID 5. BusNumber 6. DeviceNumber 7. FunctionNumber

OEMSECommands for the group

None

Table 22: PCI

Page 57: PRIMERGY BX600 10GbE LAN I/O Module (PCIe) - Fujitsumanuals.ts.fujitsu.com/file/8372/bx-10gbe-sm-clp-ref-win08.pdf · PRIMERGY BX600 10GbE LAN I/O Module ... Microsoft Windows Server

6.1.21. iSNS

String Identifier iSNS Group Description This group stores the iSNS discovery parameters. Attributes static MultiInstance No MaxInstance N/A Parent GroupName iSCSIPhysicalHBA

Subgroups 1. iSNSServer

Properties for the group 1. iSNSEnabled

OEMSECommands for the group

1. OEMSEDiscoveryiSNSThruDHCP 2. OEMSEAddiSNSServer 3. OEMSEDeleteiSNSServer

Table 23: iSNS

6.1.22. iSNSServer

String Identifier iSNSServer Group Description This group instance corresponds to an iSNS Server entry. Attributes dynamic MultiInstance Yes MaxInstance 4 Parent GroupName iSNS Subgroups None

Properties for the group 1. IPAddress 2. PortNumber

OEMSECommands for the group None

Table 24: iSNSServer

6.1.23. LogicalHBA

String Identifier LogicalHBA

Group Description This group instance corresponds to a single port of a BladeEngine controller functioning as an iSCSI initiator.

Attributes dynamic MultiInstance Yes MaxInstance 16 Parent GroupName iSCSIPhysicalHBA

Subgroups

1. InitiatoriSCSIName 2. InitiatorDefaultLoginOptions 3. InitiatorLoginOptions 4. QoS 5. iSCSIStatistics 6. Target 7. Discovery

Properties for the group 1. Enabled

OEMSECommands for the group

1. OEMSEAddTarget 2. OEMSEDeleteTarget

Page 58: PRIMERGY BX600 10GbE LAN I/O Module (PCIe) - Fujitsumanuals.ts.fujitsu.com/file/8372/bx-10gbe-sm-clp-ref-win08.pdf · PRIMERGY BX600 10GbE LAN I/O Module ... Microsoft Windows Server

Table 25: LogicalHBA

6.1.24. InitiatoriSCSIName

String Identifier InitiatoriSCSIName

Group Description This group contains iSCSI name configuration details for the initiator node.

Attributes static MultiInstance No MaxInstance N/A Parent GroupName LogicalHBA Subgroups None

Properties for the group

1. InitiatoriSCSIName 2. InitiatorAlias 3. DefaultiSCSIName

OEMSECommands for the group

None

Table 26: InitiatoriSCSIName

6.1.25. InitiatorDefaultLoginOptions

String Identifier InitiatorDefaultLoginOptions

Group Description This group contains the default login options for the iSCSI initiator node.

Attributes static MultiInstance No MaxInstance N/A Parent GroupName LogicalHBA Subgroups None

Properties for the group

1. InitialR2T 2. ImmediateData 3. MaxConnections 4. MaxOutstandingR2T 5. FirstBurstLength 6. MaxBurstLength 7. DefaultTime2Wait 8. DefaultTime2Retain 9. ErrorRecoveryLevel 10. DataPDUInOrder 11. DataSequenceInOrder 12. HeaderDigest 13. DataDigest 14. MaxRecvDataSegmentLength 15. TCPWindowSize

OEMSECommands for the group

None

Table 27: InitiatorDefaultLoginOptions

6.1.26. InitiatorLoginOptions

String Identifier InitiatorLoginOptions

Group Description This group contains the configured login options for the iSCSI initiator node.

Attributes static MultiInstance No

Page 59: PRIMERGY BX600 10GbE LAN I/O Module (PCIe) - Fujitsumanuals.ts.fujitsu.com/file/8372/bx-10gbe-sm-clp-ref-win08.pdf · PRIMERGY BX600 10GbE LAN I/O Module ... Microsoft Windows Server

MaxInstance N/A Parent GroupName LogicalHBA

Subgroups 1. Authentication

Properties for the group

1. InitialR2T 2. ImmediateData 3. HeaderDigest 4. DataDigest

OEMSECommands for the group

None

Table 28: InitiatorLoginOptions

6.1.27. Authentication

String Identifier Authentication

Group Description This group contains the configured connection authentication related login options for the iSCSI initiator node.

Attributes static MultiInstance No MaxInstance N/A Parent GroupName InitiatorLoginOptions Subgroups None

Properties for the group

1. AuthenticationMethod 2. InitiatorCHAPName 3. InitiatorSecret 4. TargetCHAPName 5. TargetSecret

OEMSECommands for the group

None

Table 29: Authentication

6.1.28. QoS

String Identifier QoS Group Description This group contains the properties of QoS. Attributes static MultiInstance No MaxInstance N/A Parent GroupName LogicalHBA Subgroups None

Properties for the group 1. MaxBytesPerSecond 2. MaxIosPerSecond

OEMSECommands for the group None

Table 30: QoS

6.1.29. iSCSIStatistics

String Identifier iSCSIStatistics Group Description This group contains all the SNMP properties. Attributes static MultiInstance No MaxInstance N/A

Page 60: PRIMERGY BX600 10GbE LAN I/O Module (PCIe) - Fujitsumanuals.ts.fujitsu.com/file/8372/bx-10gbe-sm-clp-ref-win08.pdf · PRIMERGY BX600 10GbE LAN I/O Module ... Microsoft Windows Server

Parent GroupName LogicalHBA Subgroups None

Properties for the group

1. NodeRoles 2. PortalCount 3. NodeCount 4. SessionCount 5. SessionFailureCount 6. LastSessionFailureType 7. LastSessionRmtNodeName 8. SessionDigestErrors 9. SessionConnectionTimeout 10. SessionFormatErrors 11. LoginFailures 12. LastFailureTime 13. LastFailureType 14. LastTgtFailureName 15. LastTgtFailureAddr 16. LoginAcceptRsps 17. LoginOtherFailRsps 18. LoginRedirectRsps 19. LoginAuthFailRsps 20. LoginAuthFails 21. LoginNegoFails 22. LogoutNormals 23. LogoutOthers 24. PortRowStatus 25. PortalRole 26. PortalProtocol 27. PortalTag

OEMSECommands for the group None

Table 31: iSCSIStatistics

6.1.30. Target

String Identifier Target

Group Description This group represents the information about the targets that are available in the network.

Attributes dynamic MultiInstance Yes MaxInstance 64 Parent GroupName LogicalHBA

Subgroups

1. TargetPortal 2. TargetLoginOptions 3. Session 4. LUN

Properties for the group 1. TargetISCSIName 2. TargetAlias

OEMSECommands for the group

1. OEMSELogin 2. OEMSELogout 3. OEMSEReScanLUNS

Table 32: Target

6.1.31. TargetPortal

String Identifier TargetPortal

Page 61: PRIMERGY BX600 10GbE LAN I/O Module (PCIe) - Fujitsumanuals.ts.fujitsu.com/file/8372/bx-10gbe-sm-clp-ref-win08.pdf · PRIMERGY BX600 10GbE LAN I/O Module ... Microsoft Windows Server

Group Description This group instance corresponds to a portal of the target identified by its IP address and port number.

Attributes dynamic MultiInstance Yes MaxInstance 64 Parent GroupName Target Subgroups None

Properties for the group

1. TargetIPAddress 2. TargetPortNumber 3. PortalGroupTag 4. Persistent

OEMSECommands for the group

None

Table 33: TargetPortal

6.1.32. TargetLoginOptions

String Identifier TargetLoginOptions

Group Description This group consists of the set of login options used to login to the target.

Attributes static MultiInstance No MaxInstance N/A Parent GroupName Target

Subgroups 1. Authentication

Properties for the group

1. InitialR2T 2. ImmediateData 3. HeaderDigest 4. DataDigest

OEMSECommands for the group

None

Table 34: TargetLoginOptions

6.1.33. Authentication

String Identifier Authentication

Group Description This group consists of the set of connection authentication related login options used to create an iSCSI session with the target.

Attributes static MultiInstance No MaxInstance N/A Parent GroupName TargetLoginOptions Subgroups None

Properties for the group

1. AuthenticationMethod 2. InitiatorCHAPName 3. InitiatorSecret 4. TargetCHAPName 5. TargetSecret

OEMSECommands for the group

None

Table 35: Authentication

Page 62: PRIMERGY BX600 10GbE LAN I/O Module (PCIe) - Fujitsumanuals.ts.fujitsu.com/file/8372/bx-10gbe-sm-clp-ref-win08.pdf · PRIMERGY BX600 10GbE LAN I/O Module ... Microsoft Windows Server

6.1.34. Session

String Identifier Session

Group Description This group instance corresponds to an active session with the target.

Attributes dynamic MultiInstance Yes MaxInstance 64 Parent GroupName Target

Subgroups

1. SessionNegotiatedLoginOptions 2. iSCSISessionStatistics 3. Connection

Properties for the group

1. SessionTSIH 2. ISIDQualifier 3. SessionInitiatorName 4. SessionStatus 5. iSCSIBoot 6. Persistent

OEMSECommands for the group

None

Table 36: Session

6.1.35. SessionNegotiatedLoginOptions

String Identifier SessionNegotiatedLoginOptions

Group Description This group stores the negotiated login options when the session was created.

Attributes static MultiInstance No MaxInstance N/A Parent GroupName Session Subgroups None

Properties for the group

1. InitialR2T 2. ImmediateData 3. MaxConnections 4. MaxOutstandingR2T 5. FirstBurstLength 6. MaxBurstLength 7. DefaultTime2Wait 8. DefaultTime2Retain 9. ErrorRecoveryLevel 10. DataPDUInOrder 11. DataSequenceInOrder

OEMSECommands for the group

None

Table 37: SessionNegotiatedLoginOptions

6.1.36. iSCSISessionStatistics

String Identifier iSCSISessionStatistics

Group Description This group instance corresponds to the SNMP properties under this particular session.

Attributes static MultiInstance No MaxInstance N/A

Page 63: PRIMERGY BX600 10GbE LAN I/O Module (PCIe) - Fujitsumanuals.ts.fujitsu.com/file/8372/bx-10gbe-sm-clp-ref-win08.pdf · PRIMERGY BX600 10GbE LAN I/O Module ... Microsoft Windows Server

Parent GroupName Session Subgroups None

Properties for the group

1. SessionDirection 2. CmdPdus 3. RspPdus 4. TxDataOctetsHigh 5. RxDataOctetsHigh 6. DigestErrors 7. CxnTimeoutErrors 8. SessionTargetAlias

OEMSECommands for the group

None

Table 38: iSCSISessionStatistics

6.1.37. Connection

String Identifier Connection

Group Description This group instance corresponds to a connection for a session. A session can have a maximum of four connections.

Attributes dynamic MultiInstance Yes MaxInstance 4 Parent GroupName Session

Subgroups 1. ConnectionNegotiatedLoginOptions

Properties for the group

1. iSCSIConnectionID 2. Status 3. SourcePortNumber 4. DestinationPortNumber 5. SourceIPAddress 6. DestinationIPAddress 7. RedirectedDestinationPort 8. RedirectedDestinationIPAddress

OEMSECommands for the group

None

Table 39: Connection

6.1.38. ConnectionNegotiatedLoginOptions

String Identifier ConnectionNegotiatedLoginOptions Group Description This group consists of the negotiated connection login options. Attributes static MultiInstance No MaxInstance N/A Parent GroupName Connection Subgroups None

Properties for the group

1. AuthenticationMethod 2. HeaderDigest 3. DataDigest 4. MaxRecvDataSegmentLength 5. TCPWindowSize 6. TCPMSS

OEMSECommands for the group None

Table 40: ConnectionNegotiatedLoginOptions

Page 64: PRIMERGY BX600 10GbE LAN I/O Module (PCIe) - Fujitsumanuals.ts.fujitsu.com/file/8372/bx-10gbe-sm-clp-ref-win08.pdf · PRIMERGY BX600 10GbE LAN I/O Module ... Microsoft Windows Server

6.1.39. LUN

String Identifier LUN

Group Description This group instance corresponds to a LUN available behind this target.

Attributes dynamic MultiInstance Yes MaxInstance 512 Parent GroupName Target Subgroups None

Properties for the group

1. LUNNumber 2. LUNSize 3. DeviceVendorName 4. DeviceModelNumber 5. LUNSerialNumber

OEMSECommands for the group

1. OEMSETestUnitReady 2. OEMSEStdInquiry 3. OEMSEReadCapacity 4. OEMSESCSIRead 5. OEMSESCSIWrite

Table 41: LUN

6.1.40. Discovery

String Identifier Discovery

Group Description This group stores the discovery parameters configured for the Initiator node.

Attributes static MultiInstance No MaxInstance N/A Parent GroupName LogicalHBA

Subgroups 1. SendTargetPortal

Properties for the group None

OEMSECommands for the group

1. OEMSEAddSendTargetPortal 2. OEMSEDeleteSendTargetPortal 3. OEMSERefreshAvailableTargets

Table 42: Discovery

6.1.41. SendTargetPortal

String Identifier SendTargetPortal

Group Description This group instance corresponds to a SendTarget Portal for discovering targets.

Attributes dynamic MultiInstance Yes MaxInstance 10 Parent GroupName Discovery

Subgroups 1. SendTargetPortalLoginOptions

Properties for the group 1. IPAddress 2. PortNumber 3. PortMacAddress

Page 65: PRIMERGY BX600 10GbE LAN I/O Module (PCIe) - Fujitsumanuals.ts.fujitsu.com/file/8372/bx-10gbe-sm-clp-ref-win08.pdf · PRIMERGY BX600 10GbE LAN I/O Module ... Microsoft Windows Server

4. Persistent

OEMSECommands for the group

1. OEMSEDiscoverTargets

Table 43: SendTargetPortal

6.1.42. SendTargetPortalLoginOptions

String Identifier SendTargetPortalLoginOptions

Group Description This group consists of the login options used to create a discovery session with the SendTarget Portal.

Attributes static MultiInstance No MaxInstance N/A Parent GroupName SendTargetPortal

Subgroups 1. Authentication

Properties for the group

1. InitialR2T 2. ImmediateData 3. HeaderDigest 4. DataDigest

OEMSECommands for the group

None

Table 44: SendTargetPortalLoginOptions

6.1.43. Authentication

String Identifier Authentication

Group Description This group consists of the authentication options used to create a discovery session with the SendTarget Portal.

Attributes static MultiInstance No MaxInstance N/A Parent GroupName SendTargetPortalLoginOptions Subgroups None

Properties for the group

1. InitiatorCHAPName 2. InitiatorSecret 3. TargetCHAPName 4. TargetSecret 5. AuthenticationMethod

OEMSECommands for the group

None

Table 45: Authentication

6.2. MILI_Properties

This chapter contains all the properties in all the groups of Storage Blade. Each property is described in a table with a brief description and its identification name (refered to as "StringIdentifier), Attributes (access permissions), Min/Max/Default values and its parent group.

6.2.1. MILIServiceVersion

Page 66: PRIMERGY BX600 10GbE LAN I/O Module (PCIe) - Fujitsumanuals.ts.fujitsu.com/file/8372/bx-10gbe-sm-clp-ref-win08.pdf · PRIMERGY BX600 10GbE LAN I/O Module ... Microsoft Windows Server

String Identifier MILIServiceVersion Property Description This property specifies the version number of the MiliService. Attributes Read-Only Datatype string. Minimum length of the string is 5 and maximum length of the string is 32. min Value N/A max Value N/A default Value 0 Parent GroupName ROOT

Table 46: MILIServiceVersion

6.2.2. MILIHierarchyVersion

String Identifier MILIHierarchyVersion Property Description This property specifies version number of the MILI Hierarchy. Attributes Read-Only Datatype string. Minimum length of the string is 3 and maximum length of the string is 32. min Value N/A max Value N/A default Value 0 Parent GroupName ROOT

Table 47: MILIHierarchyVersion

6.2.3. Manufacturer

String Identifier Manufacturer Property Description This property names the manufacturer of the BladeEngine controller. Attributes Read-Only Datatype string. Minimum length of the string is 0 and maximum length of the string is 32. min Value N/A max Value N/A default Value 0 Parent GroupName BladeEngine

Table 48: Manufacturer

6.2.4. ModelNumber

String Identifier ModelNumber Property Description This property specifies the model number of the BladeEngine controller. Attributes Read-Only Datatype string. Minimum length of the string is 1 and maximum length of the string is 32. min Value N/A max Value N/A default Value 1 Parent GroupName BladeEngine

Table 49: ModelNumber

6.2.5. Description

String Identifier Description Property Description This property describes the BladeEngine controller. Attributes Read-Only Datatype string. Minimum length of the string is 0 and maximum length of the string is 64. min Value N/A

Page 67: PRIMERGY BX600 10GbE LAN I/O Module (PCIe) - Fujitsumanuals.ts.fujitsu.com/file/8372/bx-10gbe-sm-clp-ref-win08.pdf · PRIMERGY BX600 10GbE LAN I/O Module ... Microsoft Windows Server

max Value N/A default Value 0 Parent GroupName BladeEngine

Table 50: Description

6.2.6. SerialNumber

String Identifier SerialNumber Property Description

This property specifies the serial number of the BladeEngine controller. The serial number is typically one of the MAC addresses assocated with BladeEngine.

Attributes Read-Only Datatype string. Minimum length of the string is 1 and maximum length of the string is 32. min Value N/A max Value N/A default Value 1 Parent GroupName

BladeEngine

Table 51: SerialNumber

6.2.7. ActiveFirmwareVersion

String Identifier ActiveFirmwareVersion Property Description

This property specifies the firmware version that is currently operational on the BladeEngine controller.

Attributes Read-Only Datatype string. Minimum length of the string is 5 and maximum length of the string is 32. min Value N/A max Value N/A default Value 5 Parent GroupName

BladeEngine

Table 52: ActiveFirmwareVersion

6.2.8. FirmwareVersionOnFlash

String Identifier

FirmwareVersionOnFlash

Property Description

This property specifies the firmware version stored on BladeEngine's non-volatile storage. The next time the system restarts, this version will become the active firmware version.

Attributes Read-Only Datatype string. Minimum length of the string is 5 and maximum length of the string is 32. min Value N/A max Value N/A default Value 5 Parent GroupName

BladeEngine

Table 53: FirmwareVersionOnFlash

6.2.9. BIOSVersion

String Identifier BIOSVersion Property This property specifies the BIOS version which is currently operational on the

Page 68: PRIMERGY BX600 10GbE LAN I/O Module (PCIe) - Fujitsumanuals.ts.fujitsu.com/file/8372/bx-10gbe-sm-clp-ref-win08.pdf · PRIMERGY BX600 10GbE LAN I/O Module ... Microsoft Windows Server

Description BladeEngine controller. Attributes Read-Only Datatype string. Minimum length of the string is 5 and maximum length of the string is 32. min Value N/A max Value N/A default Value 5 Parent GroupName

BladeEngine

Table 54: BIOSVersion

6.2.10. BootCodeVersion

String Identifier BootCodeVersion Property Description

This property specifies the boot code version which is currently operational on the BladeEngine controller.

Attributes Read-Only Datatype string. Minimum length of the string is 5 and maximum length of the string is 32. min Value N/A max Value N/A default Value 5 Parent GroupName

BladeEngine

Table 55: BootCodeVersion

6.2.11. FirmwareStatus

String Identifier FirmwareStatus Property Description

This property indicates the status of the BladeEngine firmware. This field will return Ready if the firmware is in a properly operating state.

Attributes Read-Only Datatype string. Minimum length of the string is 0 and maximum length of the string is 3. min Value N/A max Value N/A default Value 2 Parent GroupName

BladeEngine

Table 56: FirmwareStatus

6.2.12. iSCSIVersionMin

String Identifier iSCSIVersionMin Property Description

This field corresponds to the iSCSI RFC 3720 field iSCSIVersionMin. A value of 1 for this property indicates support for the RFC3720 specification.

Attributes Read-Only Datatype string. Minimum length of the string is 1 and maximum length of the string is 3. min Value N/A max Value N/A default Value 1 Parent GroupName

BladeEngine

Table 57: iSCSIVersionMin

6.2.13. iSCSIVersionMax

Page 69: PRIMERGY BX600 10GbE LAN I/O Module (PCIe) - Fujitsumanuals.ts.fujitsu.com/file/8372/bx-10gbe-sm-clp-ref-win08.pdf · PRIMERGY BX600 10GbE LAN I/O Module ... Microsoft Windows Server

String Identifier iSCSIVersionMax Property Description

This field corresponds to the iSCSI RFC 3720 field iSCSIVersionMax. A value of 1 for this property indicates support for the RFC3720 specification.

Attributes Read-Only Datatype string. Minimum length of the string is 1 and maximum length of the string is 3. min Value N/A max Value N/A default Value 1 Parent GroupName

BladeEngine

Table 58: iSCSIVersionMax

6.2.14. MaxCDBLength

String Identifier MaxCDBLength Property Description

This property indicates the maximum CDB length supported by this BladeEngine controller.

Attributes Read-Only Datatype integer min Value 0 max Value 16 default Value 16 Parent GroupName BladeEngine

Table 59: MaxCDBLength

6.2.15. MaxMTUSize

String Identifier MaxMTUSize Property Description

This property shows the maximum MTU supported for both iSCSI and NIC/TOE traffic for this BladeEngine controller.

Attributes Read-Only Datatype integer min Value 0 max Value 8342 default Value 0 Parent GroupName

BladeEngine

Table 60: MaxMTUSize

6.2.16. LDTO (for ESX)

String Identifier

LDTO

Property Description

This property corresponds to the Link Down Time Out (LDTO) value for this BladeEngine controller. The LDTO specifies the amount of time in seconds that BladeEngine iSCSI drivers will delay reporting an error to the operating system.

Attributes Read-Only Datatype integer min Value 0 max Value 8342 default Value 0 Parent GroupName

BladeEngine

Table 61: LDTO

Page 70: PRIMERGY BX600 10GbE LAN I/O Module (PCIe) - Fujitsumanuals.ts.fujitsu.com/file/8372/bx-10gbe-sm-clp-ref-win08.pdf · PRIMERGY BX600 10GbE LAN I/O Module ... Microsoft Windows Server

6.2.17. LDTO (for SOLARIS)

String Identifier

LDTO

Property Description

This property corresponds to the Link Down Time Out (LDTO) value for this BladeEngine controller. The LDTO specifies the amount of time in seconds that BladeEngine iSCSI drivers will delay reporting an error to the operating system.

Attributes Read-Only Datatype integer min Value 0 max Value 60 default Value 40 Parent GroupName

BladeEngine

Table 62: LDTO

6.2.18. LDTO (for WINDOWS)

String Identifier

LDTO

Property Description

This property corresponds to the Link Down Time Out (LDTO) value for this BladeEngine controller. The LDTO specifies the amount of time in seconds that BladeEngine iSCSI drivers will delay reporting an error to the operating system.

Attributes Read-Only Datatype integer min Value 0 max Value 8342 default Value 0 Parent GroupName

BladeEngine

Table 63: LDTO

6.2.19. DefaultETO (for ESX)

String Identifier DefaultETO Property Description

This property corresponds to the Default Extended Time Out (ETO) value for this BladeEngine controller.

Attributes Read-Only Datatype integer min Value -1 max Value 30 default Value -1 Parent GroupName

BladeEngine

Table 64: DefaultETO

6.2.20. DefaultETO (for WINDOWS)

String Identifier DefaultETO Property Description

This property corresponds to the Default Extended Time Out (ETO) value for this BladeEngine controller.

Attributes Read-Only Datatype integer min Value -1 max Value 3600

Page 71: PRIMERGY BX600 10GbE LAN I/O Module (PCIe) - Fujitsumanuals.ts.fujitsu.com/file/8372/bx-10gbe-sm-clp-ref-win08.pdf · PRIMERGY BX600 10GbE LAN I/O Module ... Microsoft Windows Server

default Value -1 Parent GroupName

BladeEngine

Table 65: DefaultETO

6.2.21. DefaultETO (for SOLARIS)

String Identifier DefaultETO Property Description

This property corresponds to the Default Extended Time Out (ETO) value for this BladeEngine controller.

Attributes Read-Only Datatype integer min Value -1 max Value 60 default Value -1 Parent GroupName

BladeEngine

Table 66: DefaultETO

6.2.22. VLDCapable

String Identifier

VLDCapable

Property Description

VLD is the Virtual Link Down (VLD) feature for BladeEngine. This property indicates if this BladeEngine controller includes the VLD feature. If this property is set to No, then VLD cannot be enabled.

Attributes Read-Only Datatype string. Minimum length of the string is 1 and maximum length of the string is 4. min Value N/A max Value N/A default Value No Parent GroupName

BladeEngine

Table 67: VLDCapable

6.2.23. VLDEnabled

String Identifier

VLDEnabled

Property Description

VLD is the Virtual Link Down (VLD) feature for BladeEngine. Use this property to enable or disable VLD for this BladeEngine controller using the set command. Valid values are Yes and No. To enable, set the value to Yes. The default is No.

Attributes Read-Write Datatype list. Valid values are - Yes,No. min Value N/A max Value N/A default Value No Parent GroupName

BladeEngine

Table 68: VLDEnabled

6.2.24. SequenceNumber

String Identifier SequenceNumber

Page 72: PRIMERGY BX600 10GbE LAN I/O Module (PCIe) - Fujitsumanuals.ts.fujitsu.com/file/8372/bx-10gbe-sm-clp-ref-win08.pdf · PRIMERGY BX600 10GbE LAN I/O Module ... Microsoft Windows Server

Property Description This property displays a Sequence number of the event log entry. Attributes Read-Only Datatype integer min Value 1 max Value 255 default Value 1 Parent GroupName EventLogEntry

Table 69: SequenceNumber

6.2.25. TimeStamp

String Identifier TimeStamp Property Description This property displays the Time stamp of the event log entry. Attributes Read-Only Datatype integer min Value 1 max Value 255 default Value 1 Parent GroupName EventLogEntry

Table 70: TimeStamp

6.2.26. Severity

String Identifier Severity Property Description

This property indicates the severity associated with the event log entry.

Attributes Read-Only

Datatype string. Minimum length of the string is 1 and maximum length of the string is 255.

min Value N/A max Value N/A default Value 1 Parent GroupName EventLogEntry

Table 71: Severity

6.2.27. Description

String Identifier Description Property Description

This property gives a text description of the event log entry.

Attributes Read-Only

Datatype string. Minimum length of the string is 0 and maximum length of the string is 255.

min Value N/A max Value N/A default Value 0 Parent GroupName EventLogEntry

Table 72: Description

6.2.28. ErrorCode

String Identifier ErrorCode Property This property specifies the numeric error code associated with the event log

Page 73: PRIMERGY BX600 10GbE LAN I/O Module (PCIe) - Fujitsumanuals.ts.fujitsu.com/file/8372/bx-10gbe-sm-clp-ref-win08.pdf · PRIMERGY BX600 10GbE LAN I/O Module ... Microsoft Windows Server

Description entry. Attributes Read-Only Datatype integer min Value 1 max Value 255 default Value 1 Parent GroupName EventLogEntry

Table 73: ErrorCode

6.2.29. VendorID (for ESX)

String Identifier VendorID Property Description This property displays the PCI Vendor ID. Attributes Read-Only Datatype integer min Value 1 max Value 255 default Value 1 Parent GroupName PCI

Table 74: VendorID

6.2.30. DeviceID (for ESX)

String Identifier DeviceID Property Description This property displays the PCI Device ID. Attributes Read-Only Datatype integer min Value 1 max Value 255 default Value 1 Parent GroupName PCI

Table 75: DeviceID

6.2.31. SubsysDeviceID (for ESX)

String Identifier SubsysDeviceID Property Description This property displays the PCI Subsystem Device ID. Attributes Read-Only Datatype integer min Value 1 max Value 255 default Value 1 Parent GroupName PCI

Table 76: SubsysDeviceID

6.2.32. SubsysVendorID (for ESX)

String Identifier SubsysVendorID Property Description This property displays the PCI Subsystem Vendor ID. Attributes Read-Only Datatype integer min Value 1 max Value 255

Page 74: PRIMERGY BX600 10GbE LAN I/O Module (PCIe) - Fujitsumanuals.ts.fujitsu.com/file/8372/bx-10gbe-sm-clp-ref-win08.pdf · PRIMERGY BX600 10GbE LAN I/O Module ... Microsoft Windows Server

default Value 1 Parent GroupName PCI

Table 77: SubsysVendorID

6.2.33. BusNumber (for ESX)

String Identifier BusNumber Property Description This property displays the PCI Bus Number. Attributes Read-Only Datatype integer min Value 0 max Value 255 default Value 0 Parent GroupName PCI

Table 78: BusNumber

6.2.34. DeviceNumber (for ESX)

String Identifier DeviceNumber Property Description This property displays the PCI Device Number. Attributes Read-Only Datatype integer min Value 0 max Value 32 default Value 0 Parent GroupName PCI

Table 79: DeviceNumber

6.2.35. FunctionNumber (for ESX)

String Identifier FunctionNumber Property Description This property displays the PCI Function number for the NIC function. Attributes Read-Only Datatype integer min Value 0 max Value 8 default Value 0 Parent GroupName PCI

Table 80: FunctionNumber

6.2.36. DriverName (for ESX)

String Identifier DriverName Property Description This property displays the name of the driver. Attributes Read-Only Datatype string. Minimum length of the string is 2 and maximum length of the string is 10. min Value N/A max Value N/A default Value BENIC Parent GroupName Driver

Table 81: DriverName

Page 75: PRIMERGY BX600 10GbE LAN I/O Module (PCIe) - Fujitsumanuals.ts.fujitsu.com/file/8372/bx-10gbe-sm-clp-ref-win08.pdf · PRIMERGY BX600 10GbE LAN I/O Module ... Microsoft Windows Server

6.2.37. DriverVersion (for ESX)

String Identifier DriverVersion Property Description This property displays the current version of the driver. Attributes Read-Only Datatype string. Minimum length of the string is 2 and maximum length of the string is 6. min Value N/A max Value N/A default Value 2 Parent GroupName Driver

Table 82: DriverVersion

6.2.38. IfName (for ESX)

String Identifier IfName Property Description This property displays the Interface name string for this virtual NIC interface. Attributes Read-Only Datatype string. Minimum length of the string is 1 and maximum length of the string is 32. min Value N/A max Value N/A default Value 1 Parent GroupName LogicalHBA

Table 83: IfName

6.2.39. MACAddress (for ESX)

String Identifier MACAddress Property Description

This property specifies the MAC address for this virtual NIC interface.

Attributes Read-Write

Datatype string. Minimum length of the string is 17 and maximum length of the string is 17.

min Value N/A max Value N/A default Value 00-00-00-00-00-00 Parent GroupName LogicalHBA

Table 84: MACAddress

6.2.40. VLANPriority (for ESX)

String Identifier VLANPriority Property Description This property specifies the VLAN priority for this virtual NIC interface. Attributes Read-Write Datatype integer min Value 0 max Value 7 default Value 0 Parent GroupName LogicalHBA

Table 85: VLANPriority

6.2.41. MaxBitsPerSecond (for ESX)

Page 76: PRIMERGY BX600 10GbE LAN I/O Module (PCIe) - Fujitsumanuals.ts.fujitsu.com/file/8372/bx-10gbe-sm-clp-ref-win08.pdf · PRIMERGY BX600 10GbE LAN I/O Module ... Microsoft Windows Server

String Identifier MaxBitsPerSecond Property Description

This property specifies the MaxBitsPerSecond number for this virtual NIC interface. The number 'n' indicates 'n*10Mbit' throughput on this interface.

Attributes Read-Write Datatype integer min Value 0 max Value 100 default Value 1 Parent GroupName

QoS

Table 86: MaxBitsPerSecond

6.2.42. MaxPacketsPerSecond (for ESX)

String Identifier

MaxPacketsPerSecond

Property Description

This property specifies the maximum number of packets per second of NIC traffic allowed for this domain specified in multiples of 1024. A value of 0 indicates no QoS was set and allows all available bandwidth for this domain. Valid values are 0, 6 to 800.

Attributes Read-Write Datatype integer min Value 0 max Value 800 default Value 1 Parent GroupName

QoS

Table 87: MaxPacketsPerSecond

6.2.43. DriverName

String Identifier DriverName Property Description

This property displays the name of the iSCSI driver in the host operating system.

Attributes Read-Only Datatype string. Minimum length of the string is 2 and maximum length of the string is 10. min Value N/A max Value N/A default Value BEISCSI Parent GroupName Driver

Table 88: DriverName

6.2.44. DriverVersion

String Identifier DriverVersion Property Description

This property displays the version number of the iSCSI driver currently active in the host operating system.

Attributes Read-Only Datatype string. Minimum length of the string is 2 and maximum length of the string is 6. min Value N/A max Value N/A default Value 2 Parent GroupName

Driver

Page 77: PRIMERGY BX600 10GbE LAN I/O Module (PCIe) - Fujitsumanuals.ts.fujitsu.com/file/8372/bx-10gbe-sm-clp-ref-win08.pdf · PRIMERGY BX600 10GbE LAN I/O Module ... Microsoft Windows Server

Table 89: DriverVersion

6.2.45. DHCPServerAvailable

String Identifier DHCPServerAvailable

Property Description

This property indicates whether the DHCP Server is available. If value is 'Yes', it indicates a server is available and if value is 'No', it indicates that there is no server available.

Attributes Read-Only Datatype list. Valid values are - Yes,No. min Value N/A max Value N/A default Value No Parent GroupName

DHCP

Table 90: DHCPServerAvailable

6.2.46. DHCPObtainNewIPAddress

String Identifier

DHCPObtainNewIPAddress

Property Description

This property indicates whether you can obtain a new IP address from the DHCP Server. If value is 'Yes', it indicates that an IP address is obtained from the DHCP server and if value is 'No', it indicates that an IP address is not obtained.

Attributes Read-Only Datatype list. Valid values are - Yes,No. min Value N/A max Value N/A default Value No Parent GroupName

DHCP

Table 91: DHCPObtainNewIPAddress

6.2.47. DHCPEnabled

String Identifier

DHCPEnabled

Property Description

This property indicates the current DHCP setting. Using the OEMSEConfigureDHCP command with a mandatory parameter EnableDHCP will configure DHCP. If the parameter is "True", it will enable DHCP and initiate a DHCP request. If the parameter is "False", it will disable DHCP.

Attributes Read-Only Datatype list. Valid values are - True,False. min Value N/A max Value N/A default Value False Parent GroupName

TCPIPConfiguration

Table 92: DHCPEnabled

6.2.48. InitiatorIPAddress

String Identifier InitiatorIPAddress Property Description This property specifies the IP address assigned to the port. Attributes Read-Only

Page 78: PRIMERGY BX600 10GbE LAN I/O Module (PCIe) - Fujitsumanuals.ts.fujitsu.com/file/8372/bx-10gbe-sm-clp-ref-win08.pdf · PRIMERGY BX600 10GbE LAN I/O Module ... Microsoft Windows Server

Datatype ipaddress min Value 0 max Value 16 default Value 0.0.0.0 Parent GroupName TCPIPConfiguration

Table 93: InitiatorIPAddress

6.2.49. InitiatorSubnetMask

String Identifier InitiatorSubnetMask Property Description This property specifies the Subnet mask for the port. Attributes Read-Only Datatype subnetmask min Value 0 max Value 255 default Value 255.255.255.0 Parent GroupName TCPIPConfiguration

Table 94: InitiatorSubnetMask

6.2.50. DefaultGateway

String Identifier DefaultGateway Property Description This property displays the Default Gateway specified for the port. Attributes Read-Only Datatype ipaddress min Value 0 max Value 16 default Value 0.0.0.0 Parent GroupName TCPIPConfiguration

Table 95: DefaultGateway

6.2.51. IPVersionSupported

String Identifier IPVersionSupported Property Description

This property specifies the version of IP Protocol supported. The value can be IPv4 or IPv6.

Attributes Read-Only Datatype list. Valid values are - IPv4,IPv6. min Value N/A max Value N/A default Value IPv4 Parent GroupName TCPIPConfiguration

Table 96: IPVersionSupported

6.2.52. VLANID

String Identifier VLANID Property Description This property specifies the current VLAN ID used. Attributes Read-Only Datatype integer min Value 0 max Value 4095 default Value 0

Page 79: PRIMERGY BX600 10GbE LAN I/O Module (PCIe) - Fujitsumanuals.ts.fujitsu.com/file/8372/bx-10gbe-sm-clp-ref-win08.pdf · PRIMERGY BX600 10GbE LAN I/O Module ... Microsoft Windows Server

Parent GroupName TCPIPConfiguration

Table 97: VLANID

6.2.53. PortSpeed

String Identifier PortSpeed Property Description

This property specifies the port speed settings. Possible values are Unknown, less than 1Mb, less than 1Gb, 1Gb, 10Gb.

Attributes Read-Only Datatype list. Valid values are - Unknown,less than 1Mb,less than 1Gb,1Gb,10Gb. min Value N/A max Value N/A default Value 4 Parent GroupName

NICConfiguration

Table 98: PortSpeed

6.2.54. PortMaxSpeed

String Identifier PortMaxSpeed Property Description This property specifies the maximum port speed. Attributes Read-Only Datatype integer min Value 0 max Value 4 default Value 4 Parent GroupName NICConfiguration

Table 99: PortMaxSpeed

6.2.55. MaxFrameSize

String Identifier MaxFrameSize Property Description This property specifies the maximum frame size used by the port. Attributes Read-Only Datatype integer min Value 16 max Value 32000 default Value 16000 Parent GroupName NICConfiguration

Table 100: MaxFrameSize

6.2.56. LinkStatus

String Identifier LinkStatus Property Description This property indicates whether the link is up or down. Attributes Read-Only Datatype string. Minimum length of the string is 0 and maximum length of the string is 3. min Value N/A max Value N/A default Value 2 Parent GroupName NICConfiguration

Table 101: LinkStatus

Page 80: PRIMERGY BX600 10GbE LAN I/O Module (PCIe) - Fujitsumanuals.ts.fujitsu.com/file/8372/bx-10gbe-sm-clp-ref-win08.pdf · PRIMERGY BX600 10GbE LAN I/O Module ... Microsoft Windows Server

6.2.57. ActivePort

String Identifier ActivePort Property Description This property indicates the active port on the BladeEngine controller. Attributes Read-Only Datatype list. Valid values are - Port 0,Port 1,None. min Value N/A max Value N/A default Value Port 0 Parent GroupName NICConfiguration

Table 102: ActivePort

6.2.58. MACAddress

String Identifier MACAddress Property Description

This property displays the MAC Address of the network port.

Attributes Read-Only

Datatype string. Minimum length of the string is 17 and maximum length of the string is 17.

min Value N/A max Value N/A default Value 00-00-00-00-00-00 Parent GroupName NICConfiguration

Table 103: MACAddress

6.2.59. IPAddress

String Identifier IPAddress Property Description This property specifies the destination IP address of the route table entry. Attributes Read-Only Datatype ipaddress min Value 0 max Value 16 default Value 0.0.0.0 Parent GroupName RouteTableEntry

Table 104: IPAddress

6.2.60. SubnetMask

String Identifier SubnetMask Property Description This property specifies the Subnet mask of the route table entry. Attributes Read-Only Datatype subnetmask min Value 0 max Value 255 default Value 255.255.255.0 Parent GroupName RouteTableEntry

Table 105: SubnetMask

6.2.61. Gateway

Page 81: PRIMERGY BX600 10GbE LAN I/O Module (PCIe) - Fujitsumanuals.ts.fujitsu.com/file/8372/bx-10gbe-sm-clp-ref-win08.pdf · PRIMERGY BX600 10GbE LAN I/O Module ... Microsoft Windows Server

String Identifier Gateway Property Description This property indicates the Gateway specified in the route table entry. Attributes Read-Only Datatype ipaddress min Value 1 max Value 64 default Value 1 Parent GroupName RouteTableEntry

Table 106: Gateway

6.2.62. IPAddress

String Identifier IPAddress Property Description This property specifies the IP address of the ARP table entry. Attributes Read-Only Datatype ipaddress min Value 0 max Value 16 default Value 0.0.0.0 Parent GroupName ARPTableEntry

Table 107: IPAddress

6.2.63. MACAddress

String Identifier MACAddress Property Description

This property specifies the MAC address of the ARP table entry.

Attributes Read-Only

Datatype string. Minimum length of the string is 17 and maximum length of the string is 17.

min Value N/A max Value N/A default Value 00-00-00-00-00-00 Parent GroupName ARPTableEntry

Table 108: MACAddress

6.2.64. VendorID

String Identifier VendorID Property Description

This property displays the PCI vendor ID of the BladeEngine controller's iSCSI function.

Attributes Read-Only Datatype string. Minimum length of the string is 1 and maximum length of the string is 255.min Value N/A max Value N/A default Value 1 Parent GroupName PCI

Table 109: VendorID

6.2.65. DeviceID

String Identifier DeviceID Property This property displays the PCI device ID of the BladeEngine controller's iSCSI

Page 82: PRIMERGY BX600 10GbE LAN I/O Module (PCIe) - Fujitsumanuals.ts.fujitsu.com/file/8372/bx-10gbe-sm-clp-ref-win08.pdf · PRIMERGY BX600 10GbE LAN I/O Module ... Microsoft Windows Server

Description function. Attributes Read-Only

Datatype string. Minimum length of the string is 1 and maximum length of the string is 255.

min Value N/A max Value N/A default Value 1 Parent GroupName PCI

Table 110: DeviceID

6.2.66. SubsysDeviceID

String Identifier SubsysDeviceID Property Description

This property displays the PCI subsystem device ID of the BladeEngine controller's iSCSI function.

Attributes Read-Only Datatype string. Minimum length of the string is 1 and maximum length of the string is 255. min Value N/A max Value N/A default Value 1 Parent GroupName

PCI

Table 111: SubsysDeviceID

6.2.67. SubsysVendorID

String Identifier SubsysVendorID Property Description

This property displays the PCI subsystem vendor ID of the BladeEngine controller's iSCSI function.

Attributes Read-Only Datatype string. Minimum length of the string is 1 and maximum length of the string is 255. min Value N/A max Value N/A default Value 1 Parent GroupName

PCI

Table 112: SubsysVendorID

6.2.68. BusNumber

String Identifier BusNumber Property Description

This property displays the PCI bus number of the BladeEngine controller's iSCSI function.

Attributes Read-Only Datatype string. Minimum length of the string is 0 and maximum length of the string is 255. min Value N/A max Value N/A default Value 0 Parent GroupName PCI

Table 113: BusNumber

6.2.69. DeviceNumber

Page 83: PRIMERGY BX600 10GbE LAN I/O Module (PCIe) - Fujitsumanuals.ts.fujitsu.com/file/8372/bx-10gbe-sm-clp-ref-win08.pdf · PRIMERGY BX600 10GbE LAN I/O Module ... Microsoft Windows Server

String Identifier DeviceNumber Property Description

This property displays the PCI device number of the BladeEngine controller's iSCSI function.

Attributes Read-Only Datatype string. Minimum length of the string is 0 and maximum length of the string is 32. min Value N/A max Value N/A default Value 0 Parent GroupName PCI

Table 114: DeviceNumber

6.2.70. FunctionNumber

String Identifier FunctionNumber Property Description

This property displays the PCI function number of the BladeEngine controller's iSCSI function.

Attributes Read-Only Datatype string. Minimum length of the string is 0 and maximum length of the string is 8. min Value N/A max Value N/A default Value 0 Parent GroupName PCI

Table 115: FunctionNumber

6.2.71. iSNSEnabled

String Identifier iSNSEnabled Property Description

Use this property to enable or disable iSNS using the set command. Valid values are Yes and No. To enable iSNS, set the value to Yes. The default is No.

Attributes Read-Write Datatype list. Valid values are - Yes,No. min Value N/A max Value N/A default Value No Parent GroupName

iSNS

Table 116: iSNSEnabled

6.2.72. IPAddress

String Identifier IPAddress Property Description This property indicates the IP address of the iSNS Server. Attributes Read-Only Datatype ipaddress min Value 0 max Value 0 default Value 0.0.0.0 Parent GroupName iSNSServer

Table 117: IPAddress

6.2.73. PortNumber

String Identifier PortNumber

Page 84: PRIMERGY BX600 10GbE LAN I/O Module (PCIe) - Fujitsumanuals.ts.fujitsu.com/file/8372/bx-10gbe-sm-clp-ref-win08.pdf · PRIMERGY BX600 10GbE LAN I/O Module ... Microsoft Windows Server

Property Description This property indicates the port number of the iSNS Server. Attributes Read-Only Datatype integer min Value 1024 max Value 3205 default Value 1024 Parent GroupName iSNSServer

Table 118: PortNumber

6.2.74. Enabled

String Identifier Enabled Property Description

This property indicates the status of iSCSI, whether enabled or disabled. 'True' indicates iSCSI is enabled and 'False' indicates iSCSI is disabled.

Attributes Read-Write Datatype list. Valid values are - False,True. min Value N/A max Value N/A default Value False Parent GroupName

LogicalHBA

Table 119: Enabled

6.2.75. IfName (for ESX)

String Identifier IfName Property Description This property displays the Interface name string for iSCSI. Attributes Read-Only Datatype string. Minimum length of the string is 1 and maximum length of the string is 32. min Value N/A max Value N/A default Value vmhba Parent GroupName LogicalHBA

Table 120: IfName

6.2.76. InitiatoriSCSIName

String Identifier

InitiatoriSCSIName

Property Description

This property specifies the iSCSI name (IQN or iSCSI Qualified Name) configured for the initiator node. This name is used to identify the Initiator (to an iSCSI target, for example). Use this property to set the desired iSCSI name for this Initiator using the set command. For example; set InitiatoriSCSIName="iqn.2003-07.com.serverengines;init1".

Attributes Read-Write Datatype string. Minimum length of the string is 1 and maximum length of the string is 224. min Value N/A max Value N/A default Value iqn.se Parent GroupName

InitiatoriSCSIName

Table 121: InitiatoriSCSIName

6.2.77. InitiatorAlias

Page 85: PRIMERGY BX600 10GbE LAN I/O Module (PCIe) - Fujitsumanuals.ts.fujitsu.com/file/8372/bx-10gbe-sm-clp-ref-win08.pdf · PRIMERGY BX600 10GbE LAN I/O Module ... Microsoft Windows Server

String Identifier

InitiatorAlias

Property Description

This property specifies the initiator alias allows an organization to associate a user-friendly name with the iSCSI name (IQN or iSCSI Qualified Name) of the Initiator. Use this property to set the desired iSCSI alias for this Initiator using the set command. For example; set InitiatorAlias="init1".

Attributes Read-Write Datatype string. Minimum length of the string is 0 and maximum length of the string is 32. min Value N/A max Value N/A default Value se Parent GroupName

InitiatoriSCSIName

Table 122: InitiatorAlias

6.2.78. DefaultiSCSIName

String Identifier DefaultiSCSIName Property Description

This property indicates the default iSCSI name (IQN name) specified for the initiator node.

Attributes Read-Only Datatype string. Minimum length of the string is 1 and maximum length of the string is 224. min Value N/A max Value N/A default Value iqn.2003-07.com.serverengines Parent GroupName InitiatoriSCSIName

Table 123: DefaultiSCSIName

6.2.79. InitialR2T

String Identifier

InitialR2T

Property Description

The valid values for this property are Yes or No. If set to Yes, the initiator has to wait for the target to solicit SCSI data before sending it. Setting it to No allows the initiator to send a burst of FirstBurstLength bytes unsolicited. The default is Yes.

Attributes Read-Only Datatype list. Valid values are - Yes,No. min Value N/A max Value N/A default Value Yes Parent GroupName

InitiatorDefaultLoginOptions

Table 124: InitialR2T

6.2.80. ImmediateData

String Identifier ImmediateData Property Description

This property allows the initiator to append unsolicited data to a command. The valid values are Yes or No. The default is Yes.

Attributes Read-Only Datatype list. Valid values are - Yes,No. min Value N/A max Value N/A default Value Yes Parent GroupName

InitiatorDefaultLoginOptions

Page 86: PRIMERGY BX600 10GbE LAN I/O Module (PCIe) - Fujitsumanuals.ts.fujitsu.com/file/8372/bx-10gbe-sm-clp-ref-win08.pdf · PRIMERGY BX600 10GbE LAN I/O Module ... Microsoft Windows Server

Table 125: ImmediateData

6.2.81. MaxConnections

String Identifier MaxConnections Property Description

This iSCSI login parameter indicates the maximum number of connections to targets that will be allowed within a single session. The default is 1.

Attributes Read-Only Datatype integer min Value 1 max Value 1 default Value 1 Parent GroupName

InitiatorDefaultLoginOptions

Table 126: MaxConnections

6.2.82. MaxOutstandingR2T

String Identifier

MaxOutstandingR2T

Property Description

This iSCSI login parameter indicates the maximum number of outstanding request to transmit's (R2T's) per task within a session, each up to MaxBurstLength bytes. The default is 1.

Attributes Read-Only Datatype integer min Value 1 max Value 255 default Value 1 Parent GroupName

InitiatorDefaultLoginOptions

Table 127: MaxOutstandingR2T

6.2.83. FirstBurstLength

String Identifier

FirstBurstLength

Property Description

This iSCSI login parameter indicates in bytes, the maximum amount of unsolicited data the initiator can send to the target during the execution of a single iSCSI command. The default is 8192 bytes.

Attributes Read-Only Datatype integer min Value 0 max Value 8192 default Value 8192 Parent GroupName

InitiatorDefaultLoginOptions

Table 128: FirstBurstLength

6.2.84. MaxBurstLength

String Identifier

MaxBurstLength

Property Description

This iSCSI login parameter indicates the maximum amount of either unsolicited or solicited data the initiator may send in a single burst. Any amount of data exceeding this value must be explicitly solicited by the target. This value shuld be set to multiples

Page 87: PRIMERGY BX600 10GbE LAN I/O Module (PCIe) - Fujitsumanuals.ts.fujitsu.com/file/8372/bx-10gbe-sm-clp-ref-win08.pdf · PRIMERGY BX600 10GbE LAN I/O Module ... Microsoft Windows Server

of PAGESIZE. The default value is 262144 bytes. Attributes Read-Only Datatype integer min Value 0 max Value 262144 default Value 262144 Parent GroupName

InitiatorDefaultLoginOptions

Table 129: MaxBurstLength

6.2.85. DefaultTime2Wait

String Identifier

DefaultTime2Wait

Property Description

This iSCSI login parameter indicates the minimum time to wait, in seconds, before the initiator attempts to reconnect or reassign a connection (or task) that has been dropped after an unexpected connection termination or reset. The initiator and target negotiate to determine this value.

Attributes Read-Only Datatype integer min Value 0 max Value 2 default Value 2 Parent GroupName

InitiatorDefaultLoginOptions

Table 130: DefaultTime2Wait

6.2.86. DefaultTime2Retain

String Identifier

DefaultTime2Retain

Property Description

This iSCSI login parameter indicates the maximum time, in seconds, to reassign a connection after the initial wait that is indicated in DefaultTime2Wait has elapsed. The initiator and target negotiate to determine this value.

Attributes Read-Only Datatype integer min Value 0 max Value 20 default Value 20 Parent GroupName

InitiatorDefaultLoginOptions

Table 131: DefaultTime2Retain

6.2.87. ErrorRecoveryLevel

String Identifier

ErrorRecoveryLevel

Property Description

This iSCSI login parameter indicates the operational ErrorRecoveryLevel for the session. 0 indicates recovery only by session restart. 1 indicates recovery by reissuing commands, data, or status. 2 indicates connection failure recovery. The default level is 0.

Attributes Read-Only Datatype integer min Value 0 max Value 255 default Value 0

Page 88: PRIMERGY BX600 10GbE LAN I/O Module (PCIe) - Fujitsumanuals.ts.fujitsu.com/file/8372/bx-10gbe-sm-clp-ref-win08.pdf · PRIMERGY BX600 10GbE LAN I/O Module ... Microsoft Windows Server

Parent GroupName

InitiatorDefaultLoginOptions

Table 132: ErrorRecoveryLevel

6.2.88. DataPDUInOrder

String Identifier DataPDUInOrder Property Description

This iSCSI login parameter determines the order of data PDUs within a sequence.

Attributes Read-Only Datatype integer min Value 0 max Value 1 default Value 1 Parent GroupName InitiatorDefaultLoginOptions

Table 133: DataPDUInOrder

6.2.89. DataSequenceInOrder

String Identifier DataSequenceInOrder Property Description This iSCSI login parameter determines the order between sequences. Attributes Read-Only Datatype integer min Value 0 max Value 1 default Value 1 Parent GroupName InitiatorDefaultLoginOptions

Table 134: DataSequenceInOrder

6.2.90. HeaderDigest

String Identifier

HeaderDigest

Property Description

The valid values for this property are CRC32C or None. If set to CRC32C and the initiator is configured accordingly, the integrity of an iSCSI PDU's header segments will be protected by a CRC32C checksum. The default is None.

Attributes Read-Only Datatype list. Valid values are - None,CRC32C. min Value N/A max Value N/A default Value None Parent GroupName

InitiatorDefaultLoginOptions

Table 135: HeaderDigest

6.2.91. DataDigest

String Identifier

DataDigest

Property Description

The valid values for this property are CRC32C or None. If set to CRC32C and the initiator is configured accordingly, the integrity of an iSCSI PDU's data segment will be protected by a CRC32C checksum. The default is None.

Attributes Read-Only

Page 89: PRIMERGY BX600 10GbE LAN I/O Module (PCIe) - Fujitsumanuals.ts.fujitsu.com/file/8372/bx-10gbe-sm-clp-ref-win08.pdf · PRIMERGY BX600 10GbE LAN I/O Module ... Microsoft Windows Server

Datatype list. Valid values are - None,CRC32C. min Value N/A max Value N/A default Value None Parent GroupName

InitiatorDefaultLoginOptions

Table 136: DataDigest

6.2.92. MaxRecvDataSegmentLength

String Identifier

MaxRecvDataSegmentLength

Property Description

This iSCSI login parameter defines the maximum data segment length in bytes an initiator or target can receive in an iSCSI PDU. This value should be set to multiples of PAGESIZE. The default value is 65536 bytes.

Attributes Read-Only Datatype integer min Value 0 max Value 65536 default Value 65536 Parent GroupName

InitiatorDefaultLoginOptions

Table 137: MaxRecvDataSegmentLength

6.2.93. TCPWindowSize

String Identifier

TCPWindowSize

Property Description

This iSCSI login parameter indicates the size of the target device's receive buffer for the particular connection. It represents how much data a device can handle from its peer at one time before it is passed to the application process. The TCP window throttles down the transmission speed to a level where congestion and data loss do not occur. The default is 16000.

Attributes Read-Only Datatype integer min Value 16 max Value 255 default Value 16000 Parent GroupName

InitiatorDefaultLoginOptions

Table 138: TCPWindowSize

6.2.94. InitialR2T

String Identifier

InitialR2T

Property Description

The valid values for this property are Yes or No. If set to Yes, the initiator has to wait for the target to solicit SCSI data before sending it. Setting it to No allows the initiator to send a burst of FirstBurstLength bytes unsolicited. The default is Yes.

Attributes Read-Write Datatype list. Valid values are - Yes,No. min Value N/A max Value N/A default Value Yes Parent GroupName

InitiatorLoginOptions

Page 90: PRIMERGY BX600 10GbE LAN I/O Module (PCIe) - Fujitsumanuals.ts.fujitsu.com/file/8372/bx-10gbe-sm-clp-ref-win08.pdf · PRIMERGY BX600 10GbE LAN I/O Module ... Microsoft Windows Server

Table 139: InitialR2T

6.2.95. ImmediateData

String Identifier ImmediateData Property Description

This property allows the initiator to append unsolicited data to a command. The valid values are Yes or No. The default is Yes.

Attributes Read-Write Datatype list. Valid values are - Yes,No. min Value N/A max Value N/A default Value Yes Parent GroupName

InitiatorLoginOptions

Table 140: ImmediateData

6.2.96. HeaderDigest

String Identifier

HeaderDigest

Property Description

The valid values for this property are CRC32C or None. If set to CRC32C and the initiator is configured accordingly, the integrity of an iSCSI PDU's header segments will be protected by a CRC32C checksum. The default is None.

Attributes Read-Write Datatype list. Valid values are - None,CRC32C. min Value N/A max Value N/A default Value None Parent GroupName

InitiatorLoginOptions

Table 141: HeaderDigest

6.2.97. DataDigest

String Identifier

DataDigest

Property Description

The valid values for this property are CRC32C or None. If set to CRC32C and the initiator is configured accordingly, the integrity of an iSCSI PDU's data segment will be protected by a CRC32C checksum. The default is None.

Attributes Read-Write Datatype list. Valid values are - None,CRC32C. min Value N/A max Value N/A default Value None Parent GroupName

InitiatorLoginOptions

Table 142: DataDigest

6.2.98. AuthenticationMethod

String Identifier AuthenticationMethod Property Description

Use this property to specify an authentication method using the set command. Valid CHAP values are None, Mutual CHAP, and One-Way CHAP. None is the default.

Attributes Read-Write Datatype list. Valid values are - None,Mutual CHAP,One-Way CHAP.

Page 91: PRIMERGY BX600 10GbE LAN I/O Module (PCIe) - Fujitsumanuals.ts.fujitsu.com/file/8372/bx-10gbe-sm-clp-ref-win08.pdf · PRIMERGY BX600 10GbE LAN I/O Module ... Microsoft Windows Server

min Value N/A max Value N/A default Value None Parent GroupName

Authentication

Table 143: AuthenticationMethod

6.2.99. InitiatorCHAPName

String Identifier

InitiatorCHAPName

Property Description

This property is an iSCSI authentication login parameter sent to the target. This parameter is optional and only required for Mutual CHAP authentication. Some implementations refer to this as a Username. Use the set command with this property to specify the InitiatorCHAPName. The InitiatorCHAPName can be any name or sequence of numbers.

Attributes Read-Write Datatype string. Minimum length of the string is 1 and maximum length of the string is 256. min Value N/A max Value N/A default Value Parent GroupName

Authentication

Table 144: InitiatorCHAPName

6.2.100. InitiatorSecret

String Identifier

InitiatorSecret

Property Description

This property is an iSCSI authentication login parameter sent to the target. This is an optional parameter and only required for Mutual CHAP authentication. The secret will be displayed as plain text (and not obfuscated); both while keying and displaying. Use the set command with this property to specify the InitiatorSecret. The InitiatorSecret can be any name or sequence of numbers.

Attributes Read-Write Datatype string. Minimum length of the string is 12 and maximum length of the string is 16. min Value N/A max Value N/A default Value DefaultValue Parent GroupName

Authentication

Table 145: InitiatorSecret

6.2.101. TargetCHAPName

String Identifier

TargetCHAPName

Property Description

This property is an iSCSI authentication login parameter sent to the Target. This is a required parameter for both One-Way CHAP and Mutual CHAP authentication. Some implementations refer to this as a Username. Use the set command with this property to specify the TargetCHAPName. The TargetCHAPName can be any name or sequence of numbers.

Attributes Read-Write Datatype string. Minimum length of the string is 1 and maximum length of the string is 256. min Value N/A max Value N/A

Page 92: PRIMERGY BX600 10GbE LAN I/O Module (PCIe) - Fujitsumanuals.ts.fujitsu.com/file/8372/bx-10gbe-sm-clp-ref-win08.pdf · PRIMERGY BX600 10GbE LAN I/O Module ... Microsoft Windows Server

default Value Parent GroupName

Authentication

Table 146: TargetCHAPName

6.2.102. TargetSecret

String Identifier

TargetSecret

Property Description

This property is an iSCSI authentication login parameter sent to the target. This is a required parameter for both One-Way CHAP and Mutual CHAP authentication. The secret will be displayed as plain text (and not obfuscated); both while keying and displaying. Use the set command with this property to specify the TargetSecret. The TargetSecret can be any name or sequence of numbers.

Attributes Read-Write Datatype string. Minimum length of the string is 12 and maximum length of the string is 16. min Value N/A max Value N/A default Value DefaultValue Parent GroupName

Authentication

Table 147: TargetSecret

6.2.103. MaxBytesPerSecond

String Identifier

MaxBytesPerSecond

Property Description

This property represents the maximum iSCSI throughput for this domain, specified in 1MBps multiples. A value of 0 indicates no QoS was set and allows all available bandwidth for this domain.

Attributes Read-Write Datatype integer min Value 0 max Value 1280 default Value 0 Parent GroupName

QoS

Table 148: MaxBytesPerSecond

6.2.104. MaxIosPerSecond

String Identifier

MaxIosPerSecond

Property Description

This property represents the maximum number of I/Os per second of iSCSI traffic for this domain, specified in multiple of 1024. A value of 0 indicates no QoS was set and allows all available bandwidth for this domain.

Attributes Read-Write Datatype integer min Value 0 max Value 150 default Value 0 Parent GroupName

QoS

Table 149: MaxIosPerSecond

Page 93: PRIMERGY BX600 10GbE LAN I/O Module (PCIe) - Fujitsumanuals.ts.fujitsu.com/file/8372/bx-10gbe-sm-clp-ref-win08.pdf · PRIMERGY BX600 10GbE LAN I/O Module ... Microsoft Windows Server

6.2.105. NodeRoles

String Identifier NodeRoles Property Description

This property indicates the node role for this iSCSI initiator.

Attributes Read-Only

Datatype string. Minimum length of the string is 1 and maximum length of the string is 255.

min Value N/A max Value N/A default Value 1 Parent GroupName iSCSIStatistics

Table 150: NodeRoles

6.2.106. PortalCount

String Identifier PortalCount Property Description

This property indicates the number of rows in the iscsiPortaltypeTable which are currently associated with this iSCSI instance.

Attributes Read-Only Datatype integer min Value 1 max Value 5 default Value 1 Parent GroupName

iSCSIStatistics

Table 151: PortalCount

6.2.107. NodeCount

String Identifier NodeCount Property Description

This property indicates number of rows in the iscsiNodetypeTable which are currently associated with this iSCSI instance.

Attributes Read-Only Datatype integer min Value 1 max Value 5 default Value 1 Parent GroupName

iSCSIStatistics

Table 152: NodeCount

6.2.108. SessionCount

String Identifier SessionCount Property Description

This property the number of rows in the iscsiSessiontypeTable which are currently associated with this iSCSI instance.

Attributes Read-Only Datatype integer min Value 1 max Value 5 default Value 1 Parent GroupName

iSCSIStatistics

Page 94: PRIMERGY BX600 10GbE LAN I/O Module (PCIe) - Fujitsumanuals.ts.fujitsu.com/file/8372/bx-10gbe-sm-clp-ref-win08.pdf · PRIMERGY BX600 10GbE LAN I/O Module ... Microsoft Windows Server

Table 153: SessionCount

6.2.109. SessionFailureCount

String Identifier SessionFailureCount Property Description

This property indicates the number of times a session belonging to this instance has failed.

Attributes Read-Only Datatype integer min Value 1 max Value 255 default Value 1 Parent GroupName iSCSIStatistics

Table 154: SessionFailureCount

6.2.110. LastSessionFailureType

String Identifier LastSessionFailureType Property Description

This property indicates the type of failure encountered in the last session failure.

Attributes Read-Only

Datatype string. Minimum length of the string is 1 and maximum length of the string is 255.

min Value N/A max Value N/A default Value 1 Parent GroupName iSCSIStatistics

Table 155: LastSessionFailureType

6.2.111. LastSessionRmtNodeName

String Identifier LastSessionRmtNodeName Property Description

This property indicates the iSCSI name of the remote node from the failed session.

Attributes Read-Only

Datatype string. Minimum length of the string is 1 and maximum length of the string is 224.

min Value N/A max Value N/A default Value iqn.se Parent GroupName iSCSIStatistics

Table 156: LastSessionRmtNodeName

6.2.112. SessionDigestErrors

String Identifier SessionDigestErrors Property Description

This property indicates the count of sessions which failed due to receipt of a PDU containing header or data digest errors.

Attributes Read-Only Datatype string. Minimum length of the string is 4 and maximum length of the string is 0. min Value N/A max Value N/A default Value 4 Parent GroupName

iSCSIStatistics

Page 95: PRIMERGY BX600 10GbE LAN I/O Module (PCIe) - Fujitsumanuals.ts.fujitsu.com/file/8372/bx-10gbe-sm-clp-ref-win08.pdf · PRIMERGY BX600 10GbE LAN I/O Module ... Microsoft Windows Server

Table 157: SessionDigestErrors

6.2.113. SessionConnectionTimeout

String Identifier SessionConnectionTimeout Property Description

This property indicates the count of sessions which failed due to a sequence exceeding a time limit.

Attributes Read-Only Datatype string. Minimum length of the string is 4 and maximum length of the string is 0. min Value N/A max Value N/A default Value 4 Parent GroupName

iSCSIStatistics

Table 158: SessionConnectionTimeout

6.2.114. SessionFormatErrors

String Identifier SessionFormatErrors Property Description

This property indicates the count of sessions which failed due to receipt of an iSCSI PDU that contained a format error.

Attributes Read-Only Datatype string. Minimum length of the string is 4 and maximum length of the string is 0. min Value N/A max Value N/A default Value 4 Parent GroupName

iSCSIStatistics

Table 159: SessionFormatErrors

6.2.115. LoginFailures

String Identifier LoginFailures Property Description This property indicates the number of times a login from this initiator failed. Attributes Read-Only Datatype string. Minimum length of the string is 4 and maximum length of the string is 0. min Value N/A max Value N/A default Value 4 Parent GroupName iSCSIStatistics

Table 160: LoginFailures

6.2.116. LastFailureTime

String Identifier LastFailureTime Property Description

This property displays the timestamp of the most recent failure of a login attempt from this initiator. A value of zero indicates that no failures have occurred.

Attributes Read-Only Datatype string. Minimum length of the string is 0 and maximum length of the string is 32. min Value N/A max Value N/A default Value 0 Parent GroupName

iSCSIStatistics

Page 96: PRIMERGY BX600 10GbE LAN I/O Module (PCIe) - Fujitsumanuals.ts.fujitsu.com/file/8372/bx-10gbe-sm-clp-ref-win08.pdf · PRIMERGY BX600 10GbE LAN I/O Module ... Microsoft Windows Server

Table 161: LastFailureTime

6.2.117. LastFailureType

String Identifier LastFailureType Property Description

This property indicates the failure type for the most recent login failure on this initiator.

Attributes Read-Only Datatype string. Minimum length of the string is 0 and maximum length of the string is 0. min Value N/A max Value N/A default Value 0 Parent GroupName iSCSIStatistics

Table 162: LastFailureType

6.2.118. LastTgtFailureName

String Identifier LastTgtFailureName Property Description

This property indicates the UTF-8 string name of the target that most recently failed a login request from this initiator.

Attributes Read-Only Datatype string. Minimum length of the string is 1 and maximum length of the string is 224. min Value N/A max Value N/A default Value iqn.se Parent GroupName

iSCSIStatistics

Table 163: LastTgtFailureName

6.2.119. LastTgtFailureAddr

String Identifier LastTgtFailureAddr Property Description

This property indicates an Internet Network Address of the type specified by the object iscsiIntrLastTgtFailureAddrType.

Attributes Read-Only Datatype string. Minimum length of the string is 0 and maximum length of the string is 0. min Value N/A max Value N/A default Value 0 Parent GroupName

iSCSIStatistics

Table 164: LastTgtFailureAddr

6.2.120. LoginAcceptRsps

String Identifier LoginAcceptRsps Property Description

This property indicates the count of Login Response PDUs received by this initiator that were accepted.

Attributes Read-Only Datatype string. Minimum length of the string is 4 and maximum length of the string is 0. min Value N/A max Value N/A default Value 4 Parent iSCSIStatistics

Page 97: PRIMERGY BX600 10GbE LAN I/O Module (PCIe) - Fujitsumanuals.ts.fujitsu.com/file/8372/bx-10gbe-sm-clp-ref-win08.pdf · PRIMERGY BX600 10GbE LAN I/O Module ... Microsoft Windows Server

GroupName

Table 165: LoginAcceptRsps

6.2.121. LoginOtherFailRsps

String Identifier LoginOtherFailRsps Property Description

This property indicates the count of Login Response PDUs received by this initiator with any status code not counted by the other objects as defined for this MIB.

Attributes Read-Only Datatype string. Minimum length of the string is 4 and maximum length of the string is 0. min Value N/A max Value N/A default Value 4 Parent GroupName

iSCSIStatistics

Table 166: LoginOtherFailRsps

6.2.122. LoginRedirectRsps

String Identifier LoginRedirectRsps Property Description

This property indicates the count of Login Response PDUs received by the initiator with status class Redirection.

Attributes Read-Only Datatype string. Minimum length of the string is 4 and maximum length of the string is 0. min Value N/A max Value N/A default Value 4 Parent GroupName

iSCSIStatistics

Table 167: LoginRedirectRsps

6.2.123. LoginAuthFailRsps

String Identifier LoginAuthFailRsps Property Description

This property indicates the count of Login Response PDUs with status class 0x201 Authentication Failed received by this initiator.

Attributes Read-Only Datatype string. Minimum length of the string is 4 and maximum length of the string is 0. min Value N/A max Value N/A default Value 4 Parent GroupName

iSCSIStatistics

Table 168: LoginAuthFailRsps

6.2.124. LoginAuthFails

String Identifier LoginAuthFails Property Description

This property indicates the number of times the initiator has aborted a login because the target could not be authenticated.

Attributes Read-Only Datatype string. Minimum length of the string is 4 and maximum length of the string is 0. min Value N/A

Page 98: PRIMERGY BX600 10GbE LAN I/O Module (PCIe) - Fujitsumanuals.ts.fujitsu.com/file/8372/bx-10gbe-sm-clp-ref-win08.pdf · PRIMERGY BX600 10GbE LAN I/O Module ... Microsoft Windows Server

max Value N/A default Value 4 Parent GroupName

iSCSIStatistics

Table 169: LoginAuthFails

6.2.125. LoginNegoFails

String Identifier LoginNegoFails Property Description

This property indicates the number of times the initiator has aborted a login because parameter negotiation with the target failed.

Attributes Read-Only Datatype string. Minimum length of the string is 4 and maximum length of the string is 0. min Value N/A max Value N/A default Value 4 Parent GroupName

iSCSIStatistics

Table 170: LoginNegoFails

6.2.126. LogoutNormals

String Identifier LogoutNormals Property Description

This property indicates the count of Logout Command PDUs generated by this initiator with reason code normal.

Attributes Read-Only Datatype string. Minimum length of the string is 4 and maximum length of the string is 0. min Value N/A max Value N/A default Value 4 Parent GroupName

iSCSIStatistics

Table 171: LogoutNormals

6.2.127. LogoutOthers

String Identifier LogoutOthers Property Description

This property indicates the count of Logout Command PDUs generated by this initiator with any status code other than normal.

Attributes Read-Only Datatype string. Minimum length of the string is 4 and maximum length of the string is 0. min Value N/A max Value N/A default Value 4 Parent GroupName

iSCSIStatistics

Table 172: LogoutOthers

6.2.128. PortRowStatus

String Identifier PortRowStatus Property Description

This field allows entries to be dynamically added and removed from this table via SNMP.

Page 99: PRIMERGY BX600 10GbE LAN I/O Module (PCIe) - Fujitsumanuals.ts.fujitsu.com/file/8372/bx-10gbe-sm-clp-ref-win08.pdf · PRIMERGY BX600 10GbE LAN I/O Module ... Microsoft Windows Server

Attributes Read-Only Datatype string. Minimum length of the string is 0 and maximum length of the string is 3. min Value N/A max Value N/A default Value 2 Parent GroupName iSCSIStatistics

Table 173: PortRowStatus

6.2.129. PortalRole

String Identifier PortalRole Property Description

This property describes the role of a portal. A portal can operate in either one or both of two roles as a target portal and/or an initiator portal.

Attributes Read-Only Datatype string. Minimum length of the string is 1 and maximum length of the string is 2. min Value N/A max Value N/A default Value 1 Parent GroupName

iSCSIStatistics

Table 174: PortalRole

6.2.130. PortalProtocol

String Identifier PortalProtocol Property Description This property indicates the portal's transport protocol. Attributes Read-Only Datatype string. Minimum length of the string is 1 and maximum length of the string is 2. min Value N/A max Value N/A default Value 1 Parent GroupName iSCSIStatistics

Table 175: PortalProtocol

6.2.131. PortalTag

String Identifier PortalTag Property Description

This property indicates the portals aggregation tag when the portal is used as an initiator.

Attributes Read-Only

Datatype string. Minimum length of the string is 1 and maximum length of the string is 65535.

min Value N/A max Value N/A default Value 1 Parent GroupName iSCSIStatistics

Table 176: PortalTag

6.2.132. TargetIPAddress

String Identifier TargetIPAddress Property Description This property specifies the IP address of the target portal. Attributes Read-Only

Page 100: PRIMERGY BX600 10GbE LAN I/O Module (PCIe) - Fujitsumanuals.ts.fujitsu.com/file/8372/bx-10gbe-sm-clp-ref-win08.pdf · PRIMERGY BX600 10GbE LAN I/O Module ... Microsoft Windows Server

Datatype ipaddress min Value 0 max Value 0 default Value 0.0.0.0 Parent GroupName TargetPortal

Table 177: TargetIPAddress

6.2.133. TargetPortNumber

String Identifier TargetPortNumber Property Description This property specifies the port number of the target portal. Attributes Read-Only Datatype integer min Value 1 max Value 65535 default Value 1036 Parent GroupName TargetPortal

Table 178: TargetPortNumber

6.2.134. PortalGroupTag

String Identifier PortalGroupTag Property Description This property indicates the tag associated with the Portal Group. Attributes Read-Only Datatype integer min Value 0 max Value 255 default Value 0 Parent GroupName TargetPortal

Table 179: PortalGroupTag

6.2.135. Persistent

String Identifier Persistent Property Description

This property indicates the persistent status of the portal. If set to 'True', the portal is marked as persistent. The default value is 'False'.

Attributes Read-Write Datatype list. Valid values are - False,True. min Value N/A max Value N/A default Value False Parent GroupName

TargetPortal

Table 180: Persistent

6.2.136. InitialR2T

String Identifier

InitialR2T

Property Description

The valid values for this property are Yes or No. If set to Yes, the initiator has to wait for the target to solicit SCSI data before sending it. Setting it to No allows the initiator to send a burst of FirstBurstLength bytes unsolicited. The default is Yes.

Attributes Read-Write

Page 101: PRIMERGY BX600 10GbE LAN I/O Module (PCIe) - Fujitsumanuals.ts.fujitsu.com/file/8372/bx-10gbe-sm-clp-ref-win08.pdf · PRIMERGY BX600 10GbE LAN I/O Module ... Microsoft Windows Server

Datatype list. Valid values are - Yes,No. min Value N/A max Value N/A default Value Yes Parent GroupName

TargetLoginOptions

Table 181: InitialR2T

6.2.137. ImmediateData

String Identifier ImmediateData Property Description

This property allows the initiator to append unsolicited data to a command. The valid values are Yes or No. The default is Yes.

Attributes Read-Write Datatype list. Valid values are - Yes,No. min Value N/A max Value N/A default Value Yes Parent GroupName

TargetLoginOptions

Table 182: ImmediateData

6.2.138. HeaderDigest

String Identifier

HeaderDigest

Property Description

The valid values for this property are CRC32C or None. If set to CRC32C and the initiator is configured accordingly, the integrity of an iSCSI PDU's header segments will be protected by a CRC32C checksum. The default is None.

Attributes Read-Write Datatype list. Valid values are - None,CRC32C. min Value N/A max Value N/A default Value None Parent GroupName

TargetLoginOptions

Table 183: HeaderDigest

6.2.139. DataDigest

String Identifier

DataDigest

Property Description

The valid values for this property are CRC32C or None. If set to CRC32C and the initiator is configured accordingly, the integrity of an iSCSI PDU's data segment will be protected by a CRC32C checksum. The default is None.

Attributes Read-Write Datatype list. Valid values are - None,CRC32C. min Value N/A max Value N/A default Value None Parent GroupName

TargetLoginOptions

Table 184: DataDigest

Page 102: PRIMERGY BX600 10GbE LAN I/O Module (PCIe) - Fujitsumanuals.ts.fujitsu.com/file/8372/bx-10gbe-sm-clp-ref-win08.pdf · PRIMERGY BX600 10GbE LAN I/O Module ... Microsoft Windows Server

6.2.140. AuthenticationMethod

String Identifier AuthenticationMethod Property Description

Use this property to specify an authentication method using the set command. Valid CHAP values are None, Mutual CHAP, and One-Way CHAP. None is the default.

Attributes Read-Write Datatype list. Valid values are - None,Mutual CHAP,One-Way CHAP. min Value N/A max Value N/A default Value None Parent GroupName

Authentication

Table 185: AuthenticationMethod

6.2.141. InitiatorCHAPName

String Identifier

InitiatorCHAPName

Property Description

This property is an iSCSI authentication login parameter sent to the target. This parameter is optional and only required for Mutual CHAP authentication. Some implementations refer to this as a Username. Use the set command with this property to specify the InitiatorCHAPName. The InitiatorCHAPName can be any name or sequence of numbers.

Attributes Read-Write Datatype string. Minimum length of the string is 1 and maximum length of the string is 256. min Value N/A max Value N/A default Value Parent GroupName

Authentication

Table 186: InitiatorCHAPName

6.2.142. InitiatorSecret

String Identifier

InitiatorSecret

Property Description

This property is an iSCSI authentication login parameter sent to the target. This is an optional parameter and only required for Mutual CHAP authentication. The secret will be displayed as plain text (and not obfuscated); both while keying and displaying. Use the set command with this property to specify the InitiatorSecret. The InitiatorSecret can be any name or sequence of numbers.

Attributes Read-Write Datatype string. Minimum length of the string is 12 and maximum length of the string is 16. min Value N/A max Value N/A default Value DefaultValue Parent GroupName

Authentication

Table 187: InitiatorSecret

6.2.143. TargetCHAPName

String Identifier

TargetCHAPName

Property This property is an iSCSI authentication login parameter sent to the Target. This is a

Page 103: PRIMERGY BX600 10GbE LAN I/O Module (PCIe) - Fujitsumanuals.ts.fujitsu.com/file/8372/bx-10gbe-sm-clp-ref-win08.pdf · PRIMERGY BX600 10GbE LAN I/O Module ... Microsoft Windows Server

Description required parameter for both One-Way CHAP and Mutual CHAP authentication. Some implementations refer to this as a Username. Use the set command with this property to specify the TargetCHAPName. The TargetCHAPName can be any name or sequence of numbers.

Attributes Read-Write Datatype string. Minimum length of the string is 1 and maximum length of the string is 256. min Value N/A max Value N/A default Value Parent GroupName

Authentication

Table 188: TargetCHAPName

6.2.144. TargetSecret

String Identifier

TargetSecret

Property Description

This property is an iSCSI authentication login parameter sent to the target. This is a required parameter for both One-Way CHAP and Mutual CHAP authentication. The secret will be displayed as plain text (and not obfuscated); both while keying and displaying. Use the set command with this property to specify the TargetSecret. The TargetSecret can be any name or sequence of numbers.

Attributes Read-Write Datatype string. Minimum length of the string is 12 and maximum length of the string is 16. min Value N/A max Value N/A default Value DefaultValue Parent GroupName

Authentication

Table 189: TargetSecret

6.2.145. InitialR2T

String Identifier

InitialR2T

Property Description

The valid values for this property are Yes or No. If set to Yes, the initiator has to wait for the target to solicit SCSI data before sending it. Setting it to No allows the initiator to send a burst of FirstBurstLength bytes unsolicited. The default is Yes.

Attributes Read-Only Datatype list. Valid values are - Yes,No. min Value N/A max Value N/A default Value Yes Parent GroupName

SessionNegotiatedLoginOptions

Table 190: InitialR2T

6.2.146. ImmediateData

String Identifier ImmediateData Property Description

This property allows the initiator to append unsolicited data to a command. The valid values are Yes or No. The default is Yes.

Attributes Read-Only Datatype list. Valid values are - Yes,No. min Value N/A max Value N/A

Page 104: PRIMERGY BX600 10GbE LAN I/O Module (PCIe) - Fujitsumanuals.ts.fujitsu.com/file/8372/bx-10gbe-sm-clp-ref-win08.pdf · PRIMERGY BX600 10GbE LAN I/O Module ... Microsoft Windows Server

default Value Yes Parent GroupName

SessionNegotiatedLoginOptions

Table 191: ImmediateData

6.2.147. MaxConnections

String Identifier MaxConnections Property Description

This iSCSI login parameter indicates the maximum number of connections to targets that will be allowed within a single session. The default is 1.

Attributes Read-Only Datatype integer min Value 1 max Value 1 default Value 1 Parent GroupName

SessionNegotiatedLoginOptions

Table 192: MaxConnections

6.2.148. MaxOutstandingR2T

String Identifier

MaxOutstandingR2T

Property Description

This iSCSI login parameter indicates the maximum number of outstanding request to transmit's (R2T's) per task within a session, each up to MaxBurstLength bytes. The default is 1.

Attributes Read-Only Datatype integer min Value 1 max Value 0 default Value 1 Parent GroupName

SessionNegotiatedLoginOptions

Table 193: MaxOutstandingR2T

6.2.149. FirstBurstLength

String Identifier

FirstBurstLength

Property Description

This iSCSI login parameter indicates in bytes, the maximum amount of unsolicited data the initiator can send to the target during the execution of a single iSCSI command. The default is 8192 bytes.

Attributes Read-Only Datatype integer min Value 0 max Value 8192 default Value 8192 Parent GroupName

SessionNegotiatedLoginOptions

Table 194: FirstBurstLength

6.2.150. MaxBurstLength

String MaxBurstLength

Page 105: PRIMERGY BX600 10GbE LAN I/O Module (PCIe) - Fujitsumanuals.ts.fujitsu.com/file/8372/bx-10gbe-sm-clp-ref-win08.pdf · PRIMERGY BX600 10GbE LAN I/O Module ... Microsoft Windows Server

Identifier

Property Description

This iSCSI login parameter indicates the maximum amount of either unsolicited or solicited data the initiator may send in a single burst. Any amount of data exceeding this value must be explicitly solicited by the target. This value shuld be set to multiples of PAGESIZE. The default value is 262144 bytes.

Attributes Read-Only Datatype integer min Value 0 max Value 262144 default Value 262144 Parent GroupName

SessionNegotiatedLoginOptions

Table 195: MaxBurstLength

6.2.151. DefaultTime2Wait

String Identifier

DefaultTime2Wait

Property Description

This iSCSI login parameter indicates the minimum time to wait, in seconds, before the initiator attempts to reconnect or reassign a connection (or task) that has been dropped after an unexpected connection termination or reset. The initiator and target negotiate to determine this value.

Attributes Read-Only Datatype integer min Value 0 max Value 2 default Value 2 Parent GroupName

SessionNegotiatedLoginOptions

Table 196: DefaultTime2Wait

6.2.152. DefaultTime2Retain

String Identifier

DefaultTime2Retain

Property Description

This iSCSI login parameter indicates the maximum time, in seconds, to reassign a connection after the initial wait that is indicated in DefaultTime2Wait has elapsed. The initiator and target negotiate to determine this value.

Attributes Read-Only Datatype integer min Value 0 max Value 20 default Value 20 Parent GroupName

SessionNegotiatedLoginOptions

Table 197: DefaultTime2Retain

6.2.153. ErrorRecoveryLevel

String Identifier

ErrorRecoveryLevel

Property Description

This iSCSI login parameter indicates the operational ErrorRecoveryLevel for the session. 0 indicates recovery only by session restart. 1 indicates recovery by reissuing commands, data, or status. 2 indicates connection failure recovery. The default level is 0.

Attributes Read-Only

Page 106: PRIMERGY BX600 10GbE LAN I/O Module (PCIe) - Fujitsumanuals.ts.fujitsu.com/file/8372/bx-10gbe-sm-clp-ref-win08.pdf · PRIMERGY BX600 10GbE LAN I/O Module ... Microsoft Windows Server

Datatype integer min Value 0 max Value 0 default Value 0 Parent GroupName

SessionNegotiatedLoginOptions

Table 198: ErrorRecoveryLevel

6.2.154. DataPDUInOrder

String Identifier DataPDUInOrder Property Description

This iSCSI login parameter determines the order of data PDUs within a sequence.

Attributes Read-Only Datatype integer min Value 0 max Value 1 default Value 1 Parent GroupName SessionNegotiatedLoginOptions

Table 199: DataPDUInOrder

6.2.155. DataSequenceInOrder

String Identifier DataSequenceInOrder Property Description This iSCSI login parameter determines the order between sequences. Attributes Read-Only Datatype integer min Value 0 max Value 1 default Value 1 Parent GroupName SessionNegotiatedLoginOptions

Table 200: DataSequenceInOrder

6.2.156. SessionDirection

String Identifier SessionDirection Property Description

This property indicates the direction of iSCSI session InboundSession and OutboundSession.

Attributes Read-Only Datatype string. Minimum length of the string is 0 and maximum length of the string is 0. min Value N/A max Value N/A default Value 0 Parent GroupName iSCSISessionStatistics

Table 201: SessionDirection

6.2.157. CmdPdus

String Identifier CmdPdus Property Description

This property indicates the count of Command PDUs transferred on this session.

Attributes Read-Only Datatype string. Minimum length of the string is 0 and maximum length of the string is 0.

Page 107: PRIMERGY BX600 10GbE LAN I/O Module (PCIe) - Fujitsumanuals.ts.fujitsu.com/file/8372/bx-10gbe-sm-clp-ref-win08.pdf · PRIMERGY BX600 10GbE LAN I/O Module ... Microsoft Windows Server

min Value N/A max Value N/A default Value 0 Parent GroupName iSCSISessionStatistics

Table 202: CmdPdus

6.2.158. RspPdus

String Identifier RspPdus Property Description

This property indicates the count of Response PDUs transferred on this session.

Attributes Read-Only Datatype string. Minimum length of the string is 0 and maximum length of the string is 0. min Value N/A max Value N/A default Value 0 Parent GroupName iSCSISessionStatistics

Table 203: RspPdus

6.2.159. TxDataOctetsHigh

String Identifier TxDataOctetsHigh Property Description

This property indicates the count of data octets that were transmitted by the local iSCSI node on this session.

Attributes Read-Only Datatype string. Minimum length of the string is 0 and maximum length of the string is 0. min Value N/A max Value N/A default Value 0 Parent GroupName

iSCSISessionStatistics

Table 204: TxDataOctetsHigh

6.2.160. RxDataOctetsHigh

String Identifier RxDataOctetsHigh Property Description

This property indicates the count of data octets that were received by the local iSCSI node on this session.

Attributes Read-Only Datatype string. Minimum length of the string is 0 and maximum length of the string is 0. min Value N/A max Value N/A default Value 0 Parent GroupName

iSCSISessionStatistics

Table 205: RxDataOctetsHigh

6.2.161. DigestErrors

String Identifier DigestErrors Property Description

This property indicates the count of PDUs which were received on the session and contained header or data digest errors.

Attributes Read-Only

Page 108: PRIMERGY BX600 10GbE LAN I/O Module (PCIe) - Fujitsumanuals.ts.fujitsu.com/file/8372/bx-10gbe-sm-clp-ref-win08.pdf · PRIMERGY BX600 10GbE LAN I/O Module ... Microsoft Windows Server

Datatype string. Minimum length of the string is 0 and maximum length of the string is 0. min Value N/A max Value N/A default Value 0 Parent GroupName

iSCSISessionStatistics

Table 206: DigestErrors

6.2.162. CxnTimeoutErrors

String Identifier CxnTimeoutErrors Property Description

This property indicates the count of connections within this session which have been terminated due to a timeout.

Attributes Read-Only Datatype string. Minimum length of the string is 0 and maximum length of the string is 0. min Value N/A max Value N/A default Value 0 Parent GroupName

iSCSISessionStatistics

Table 207: CxnTimeoutErrors

6.2.163. SessionTargetAlias

String Identifier SessionTargetAlias Property Description

This property indicates the count of PDUs which were received on the session and contained header or data digest errors.

Attributes Read-Only Datatype string. Minimum length of the string is 0 and maximum length of the string is 0. min Value N/A max Value N/A default Value 0 Parent GroupName

iSCSISessionStatistics

Table 208: SessionTargetAlias

6.2.164. AuthenticationMethod

String Identifier

AuthenticationMethod

Property Description

Use this property to specify an authentication method using the set command. Valid CHAP values are None, Mutual CHAP, and One-Way CHAP. None is the default.

Attributes Read-Only Datatype list. Valid values are - None,Mutual CHAP,One-Way CHAP. min Value N/A max Value N/A default Value None Parent GroupName

ConnectionNegotiatedLoginOptions

Table 209: AuthenticationMethod

6.2.165. HeaderDigest

Page 109: PRIMERGY BX600 10GbE LAN I/O Module (PCIe) - Fujitsumanuals.ts.fujitsu.com/file/8372/bx-10gbe-sm-clp-ref-win08.pdf · PRIMERGY BX600 10GbE LAN I/O Module ... Microsoft Windows Server

String Identifier

HeaderDigest

Property Description

The valid values for this property are CRC32C or None. If set to CRC32C and the initiator is configured accordingly, the integrity of an iSCSI PDU's header segments will be protected by a CRC32C checksum. The default is None.

Attributes Read-Only Datatype list. Valid values are - None,CRC32C. min Value N/A max Value N/A default Value None Parent GroupName

ConnectionNegotiatedLoginOptions

Table 210: HeaderDigest

6.2.166. DataDigest

String Identifier

DataDigest

Property Description

The valid values for this property are CRC32C or None. If set to CRC32C and the initiator is configured accordingly, the integrity of an iSCSI PDU's data segment will be protected by a CRC32C checksum. The default is None.

Attributes Read-Only Datatype list. Valid values are - None,CRC32C. min Value N/A max Value N/A default Value None Parent GroupName

ConnectionNegotiatedLoginOptions

Table 211: DataDigest

6.2.167. MaxRecvDataSegmentLength

String Identifier

MaxRecvDataSegmentLength

Property Description

This iSCSI login parameter defines the maximum data segment length in bytes an initiator or target can receive in an iSCSI PDU. This value should be set to multiples of PAGESIZE. The default value is 65536 bytes.

Attributes Read-Only Datatype integer min Value 0 max Value 1 default Value 0 Parent GroupName

ConnectionNegotiatedLoginOptions

Table 212: MaxRecvDataSegmentLength

6.2.168. TCPWindowSize

String Identifier

TCPWindowSize

Property Description

This iSCSI login parameter indicates the size of the target device's receive buffer for the particular connection. It represents how much data a device can handle from its peer at one time before it is passed to the application process. The TCP window throttles down the transmission speed to a level where congestion and data loss do not occur. The default is 16000.

Attributes Read-Only

Page 110: PRIMERGY BX600 10GbE LAN I/O Module (PCIe) - Fujitsumanuals.ts.fujitsu.com/file/8372/bx-10gbe-sm-clp-ref-win08.pdf · PRIMERGY BX600 10GbE LAN I/O Module ... Microsoft Windows Server

Datatype integer min Value 16 max Value 255 default Value 16000 Parent GroupName

ConnectionNegotiatedLoginOptions

Table 213: TCPWindowSize

6.2.169. TCPMSS

String Identifier

TCPMSS

Property Description

This property indicates the MSS for this connection. The Host driver uses this to determine size of data PDU whenever the BladeEngine is required to transmit the entire PDU with a single iSCSI header.

Attributes Read-Only Datatype integer min Value 1514 max Value 9216 default Value 1514 Parent GroupName

ConnectionNegotiatedLoginOptions

Table 214: TCPMSS

6.2.170. iSCSIConnectionID

String Identifier iSCSIConnectionID Property Description This property indicates the iSCSI Connection ID assigned to the connection. Attributes Read-Only Datatype integer min Value 1 max Value 32 default Value 1 Parent GroupName Connection

Table 215: iSCSIConnectionID

6.2.171. Status

String Identifier Status Property Description This property indicates the status of the connection. Attributes Read-Only Datatype string. Minimum length of the string is 0 and maximum length of the string is 32. min Value N/A max Value N/A default Value Connection Status Unknown Parent GroupName Connection

Table 216: Status

6.2.172. SourcePortNumber

String Identifier SourcePortNumber Property Description This property specifies the source port number for the connection. Attributes Read-Only

Page 111: PRIMERGY BX600 10GbE LAN I/O Module (PCIe) - Fujitsumanuals.ts.fujitsu.com/file/8372/bx-10gbe-sm-clp-ref-win08.pdf · PRIMERGY BX600 10GbE LAN I/O Module ... Microsoft Windows Server

Datatype integer min Value 1024 max Value 65535 default Value 1024 Parent GroupName Connection

Table 217: SourcePortNumber

6.2.173. DestinationPortNumber

String Identifier DestinationPortNumber Property Description This property specifies the destination port number for the connection. Attributes Read-Only Datatype integer min Value 1024 max Value 65535 default Value 1024 Parent GroupName Connection

Table 218: DestinationPortNumber

6.2.174. SourceIPAddress

String Identifier SourceIPAddress Property Description This property specifies the source IP address for the connection. Attributes Read-Only Datatype ipaddress min Value 0 max Value 0 default Value 0.0.0.0 Parent GroupName Connection

Table 219: SourceIPAddress

6.2.175. DestinationIPAddress

String Identifier DestinationIPAddress Property Description This property specifies the destination IP address for the connection. Attributes Read-Only Datatype ipaddress min Value 0 max Value 0 default Value 0.0.0.0 Parent GroupName Connection

Table 220: DestinationIPAddress

6.2.176. RedirectedDestinationPort

String Identifier RedirectedDestinationPort Property Description This property indicates the Redirected target TCP port number. Attributes Read-Only Datatype string. Minimum length of the string is 0 and maximum length of the string is 0. min Value N/A max Value N/A default Value 0 Parent GroupName Connection

Page 112: PRIMERGY BX600 10GbE LAN I/O Module (PCIe) - Fujitsumanuals.ts.fujitsu.com/file/8372/bx-10gbe-sm-clp-ref-win08.pdf · PRIMERGY BX600 10GbE LAN I/O Module ... Microsoft Windows Server

Table 221: RedirectedDestinationPort

6.2.177. RedirectedDestinationIPAddress

String Identifier RedirectedDestinationIPAddress Property Description This property indicates the Redirected target IP address. Attributes Read-Only Datatype string. Minimum length of the string is 0 and maximum length of the string is 0. min Value N/A max Value N/A default Value 0 Parent GroupName Connection

Table 222: RedirectedDestinationIPAddress

6.2.178. SessionTSIH

String Identifier

SessionTSIH

Property Description

This property displays the target session identifying handle; a tag generated by an iSCSI target to identify an iSCSI session with a specific iSCSI initiator. TSIH is generated during session establishment. A value of 0 indicates that there is no session assigned.

Attributes Read-Only Datatype string. Minimum length of the string is 0 and maximum length of the string is 0. min Value N/A max Value N/A default Value 0 Parent GroupName

Session

Table 223: SessionTSIH

6.2.179. ISIDQualifier

String Identifier ISIDQualifier Property Description

This property displays the session ISID assigned to the session. This needs to be unique for every session.

Attributes Read-Only Datatype integer min Value 0 max Value 0 default Value 0 Parent GroupName

Session

Table 224: ISIDQualifier

6.2.180. SessionInitiatorName

String Identifier SessionInitiatorName Property Description

This property displays the iSCSI name configured for the session.

Attributes Read-Only

Datatype string. Minimum length of the string is 1 and maximum length of the string is 224.

min Value N/A max Value N/A

Page 113: PRIMERGY BX600 10GbE LAN I/O Module (PCIe) - Fujitsumanuals.ts.fujitsu.com/file/8372/bx-10gbe-sm-clp-ref-win08.pdf · PRIMERGY BX600 10GbE LAN I/O Module ... Microsoft Windows Server

default Value iqn.se Parent GroupName Session

Table 225: SessionInitiatorName

6.2.181. SessionStatus

String Identifier SessionStatus Property Description This property indicates the status of the session. Attributes Read-Only Datatype string. Minimum length of the string is 0 and maximum length of the string is 32. min Value N/A max Value N/A default Value Unknown Parent GroupName Session

Table 226: SessionStatus

6.2.182. iSCSIBoot

String Identifier

iSCSIBoot

Property Description

This property indicates whether the iSCSI session is marked for use as a boot session. 'True' indicates a boot session and 'False' is a non-boot session. Note that you cannot log out of a boot session via SM-CLP.

Attributes Read-Only Datatype list. Valid values are - False,True. min Value N/A max Value N/A default Value False Parent GroupName

Session

Table 227: iSCSIBoot

6.2.183. Persistent

String Identifier Persistent Property Description

This property indicates, whether the connection is persistent across reboot. If it is 'True', the connection will be automatically restored upon reboot.

Attributes Read-Only Datatype list. Valid values are - False,True. min Value N/A max Value N/A default Value False Parent GroupName

Session

Table 228: Persistent

6.2.184. LUNNumber

String Identifier LUNNumber Property Description This property specifies the Logical unit number of the LUN. Attributes Read-Only Datatype string. Minimum length of the string is 0 and maximum length of the string is 0. min Value N/A

Page 114: PRIMERGY BX600 10GbE LAN I/O Module (PCIe) - Fujitsumanuals.ts.fujitsu.com/file/8372/bx-10gbe-sm-clp-ref-win08.pdf · PRIMERGY BX600 10GbE LAN I/O Module ... Microsoft Windows Server

max Value N/A default Value 0 Parent GroupName LUN

Table 229: LUNNumber

6.2.185. LUNSize

String Identifier LUNSize Property Description This property indicates the size of the LUN in bytes. Attributes Read-Only Datatype integer min Value 0 max Value 0 default Value 0 Parent GroupName LUN

Table 230: LUNSize

6.2.186. DeviceVendorName

String Identifier DeviceVendorName Property Description This property displays the Device Vendor Identification. Attributes Read-Only Datatype string. Minimum length of the string is 0 and maximum length of the string is 0. min Value N/A max Value N/A default Value 0 Parent GroupName LUN

Table 231: DeviceVendorName

6.2.187. DeviceModelNumber

String Identifier DeviceModelNumber Property Description This property displays the Device Product Identification. Attributes Read-Only Datatype integer min Value 0 max Value 0 default Value 0 Parent GroupName LUN

Table 232: DeviceModelNumber

6.2.188. LUNName (for ESX)

String Identifier LUNName

Property Description

This property indicates the device name as represented by ESX corresponding to this LUN. The device name is formatted as vmhba(bus number);(target id);(LUN number).

Attributes Read-Only Datatype string. Minimum length of the string is 5 and maximum length of the string is 225. min Value N/A max Value N/A default Value 0 Parent LUN

Page 115: PRIMERGY BX600 10GbE LAN I/O Module (PCIe) - Fujitsumanuals.ts.fujitsu.com/file/8372/bx-10gbe-sm-clp-ref-win08.pdf · PRIMERGY BX600 10GbE LAN I/O Module ... Microsoft Windows Server

GroupName

Table 233: LUNName

6.2.189. LUNSerialNumber

String Identifier LUNSerialNumber Property Description This property displays the Serial number of the LUN. Attributes Read-Only Datatype string. Minimum length of the string is 0 and maximum length of the string is 0. min Value N/A max Value N/A default Value 0 Parent GroupName LUN

Table 234: LUNSerialNumber

6.2.190. TargetISCSIName

String Identifier TargetISCSIName Property Description

This property indicates the iSCSI name of the target.

Attributes Read-Only

Datatype string. Minimum length of the string is 11 and maximum length of the string is 255.

min Value N/A max Value N/A default Value 11 Parent GroupName Target

Table 235: TargetISCSIName

6.2.191. TargetAlias

String Identifier TargetAlias Property Description This property indicates the alias name given to the Target node. Attributes Read-Only Datatype string. Minimum length of the string is 0 and maximum length of the string is 0. min Value N/A max Value N/A default Value 0 Parent GroupName Target

Table 236: TargetAlias

6.2.192. ETO (for ESX)

String Identifier

ETO

Property Description

This property indicates the Extended TimeOut(ETO) configured for the target. The driver will ensure that the I/Os are not errored back until this time has expired (from the time the target stopped responding).

Attributes Read-Write Datatype integer min Value -1 max Value 30 default Value -1

Page 116: PRIMERGY BX600 10GbE LAN I/O Module (PCIe) - Fujitsumanuals.ts.fujitsu.com/file/8372/bx-10gbe-sm-clp-ref-win08.pdf · PRIMERGY BX600 10GbE LAN I/O Module ... Microsoft Windows Server

Parent GroupName

Target

Table 237: ETO

6.2.193. ETO (for WINDOWS)

String Identifier

ETO

Property Description

This property indicates the Extended TimeOut(ETO) configured for the target. The driver will ensure that the I/Os are not errored back until this time has expired (from the time the target stopped responding).

Attributes Read-Write Datatype integer min Value -1 max Value 3600 default Value -1 Parent GroupName

Target

Table 238: ETO

6.2.194. ETO (for SOLARIS)

String Identifier

ETO

Property Description

This property indicates the Extended TimeOut(ETO) configured for the target. The driver will ensure that the I/Os are not errored back until this time has expired (from the time the target stopped responding).

Attributes Read-Write Datatype integer min Value -1 max Value 60 default Value -1 Parent GroupName

Target

Table 239: ETO

6.2.195. InitialR2T

String Identifier

InitialR2T

Property Description

The valid values for this property are Yes or No. If set to Yes, the initiator has to wait for the target to solicit SCSI data before sending it. Setting it to No allows the initiator to send a burst of FirstBurstLength bytes unsolicited. The default is Yes.

Attributes Read-Write Datatype list. Valid values are - Yes,No. min Value N/A max Value N/A default Value Yes Parent GroupName

SendTargetPortalLoginOptions

Table 240: InitialR2T

6.2.196. ImmediateData

Page 117: PRIMERGY BX600 10GbE LAN I/O Module (PCIe) - Fujitsumanuals.ts.fujitsu.com/file/8372/bx-10gbe-sm-clp-ref-win08.pdf · PRIMERGY BX600 10GbE LAN I/O Module ... Microsoft Windows Server

String Identifier ImmediateData Property Description

This property allows the initiator to append unsolicited data to a command. The valid values are Yes or No. The default is Yes.

Attributes Read-Write Datatype list. Valid values are - Yes,No. min Value N/A max Value N/A default Value Yes Parent GroupName

SendTargetPortalLoginOptions

Table 241: ImmediateData

6.2.197. HeaderDigest

String Identifier

HeaderDigest

Property Description

The valid values for this property are CRC32C or None. If set to CRC32C and the initiator is configured accordingly, the integrity of an iSCSI PDU's header segments will be protected by a CRC32C checksum. The default is None.

Attributes Read-Write Datatype list. Valid values are - None,CRC32C. min Value N/A max Value N/A default Value None Parent GroupName

SendTargetPortalLoginOptions

Table 242: HeaderDigest

6.2.198. DataDigest

String Identifier

DataDigest

Property Description

The valid values for this property are CRC32C or None. If set to CRC32C and the initiator is configured accordingly, the integrity of an iSCSI PDU's data segment will be protected by a CRC32C checksum. The default is None.

Attributes Read-Write Datatype list. Valid values are - None,CRC32C. min Value N/A max Value N/A default Value None Parent GroupName

SendTargetPortalLoginOptions

Table 243: DataDigest

6.2.199. InitiatorCHAPName

String Identifier

InitiatorCHAPName

Property Description

This property is an iSCSI authentication login parameter sent to the target. This parameter is optional and only required for Mutual CHAP authentication. Some implementations refer to this as a Username. Use the set command with this property to specify the InitiatorCHAPName. The InitiatorCHAPName can be any name or sequence of numbers.

Attributes Read-Write Datatype string. Minimum length of the string is 1 and maximum length of the string is 256. min Value N/A

Page 118: PRIMERGY BX600 10GbE LAN I/O Module (PCIe) - Fujitsumanuals.ts.fujitsu.com/file/8372/bx-10gbe-sm-clp-ref-win08.pdf · PRIMERGY BX600 10GbE LAN I/O Module ... Microsoft Windows Server

max Value N/A default Value Parent GroupName

Authentication

Table 244: InitiatorCHAPName

6.2.200. InitiatorSecret

String Identifier

InitiatorSecret

Property Description

This property is an iSCSI authentication login parameter sent to the target. This is an optional parameter and only required for Mutual CHAP authentication. The secret will be displayed as plain text (and not obfuscated); both while keying and displaying. Use the set command with this property to specify the InitiatorSecret. The InitiatorSecret can be any name or sequence of numbers.

Attributes Read-Write Datatype string. Minimum length of the string is 12 and maximum length of the string is 16. min Value N/A max Value N/A default Value DefaultValue Parent GroupName

Authentication

Table 245: InitiatorSecret

6.2.201. TargetCHAPName

String Identifier

TargetCHAPName

Property Description

This property is an iSCSI authentication login parameter sent to the Target. This is a required parameter for both One-Way CHAP and Mutual CHAP authentication. Some implementations refer to this as a Username. Use the set command with this property to specify the TargetCHAPName. The TargetCHAPName can be any name or sequence of numbers.

Attributes Read-Write Datatype string. Minimum length of the string is 1 and maximum length of the string is 256. min Value N/A max Value N/A default Value Parent GroupName

Authentication

Table 246: TargetCHAPName

6.2.202. TargetSecret

String Identifier

TargetSecret

Property Description

This property is an iSCSI authentication login parameter sent to the target. This is a required parameter for both One-Way CHAP and Mutual CHAP authentication. The secret will be displayed as plain text (and not obfuscated); both while keying and displaying. Use the set command with this property to specify the TargetSecret. The TargetSecret can be any name or sequence of numbers.

Attributes Read-Write Datatype string. Minimum length of the string is 12 and maximum length of the string is 16. min Value N/A max Value N/A default Value DefaultValue

Page 119: PRIMERGY BX600 10GbE LAN I/O Module (PCIe) - Fujitsumanuals.ts.fujitsu.com/file/8372/bx-10gbe-sm-clp-ref-win08.pdf · PRIMERGY BX600 10GbE LAN I/O Module ... Microsoft Windows Server

Parent GroupName

Authentication

Table 247: TargetSecret

6.2.203. AuthenticationMethod

String Identifier AuthenticationMethod Property Description

Use this property to specify an authentication method using the set command. Valid CHAP values are None, Mutual CHAP, and One-Way CHAP. None is the default.

Attributes Read-Write Datatype list. Valid values are - None,Mutual CHAP,One-Way CHAP. min Value N/A max Value N/A default Value None Parent GroupName

Authentication

Table 248: AuthenticationMethod

6.2.204. IPAddress

String Identifier IPAddress Property Description This property indicates the IP address specified for the SendTarget Portal. Attributes Read-Only Datatype ipaddress min Value 0 max Value 0 default Value 0.0.0.0 Parent GroupName SendTargetPortal

Table 249: IPAddress

6.2.205. PortNumber

String Identifier PortNumber Property Description This property indicates the port number specified for the SendTarget Portal. Attributes Read-Only Datatype integer min Value 1024 max Value 65535 default Value 1024 Parent GroupName SendTargetPortal

Table 250: PortNumber

6.2.206. PortMacAddress

String Identifier PortMacAddress Property Description

This property specifies the mac address of the port the SendTarget portal is added to.

Attributes Read-Only Datatype macaddress min Value 17 max Value 17 default Value 00-00-00-00-00-00 Parent GroupName SendTargetPortal

Page 120: PRIMERGY BX600 10GbE LAN I/O Module (PCIe) - Fujitsumanuals.ts.fujitsu.com/file/8372/bx-10gbe-sm-clp-ref-win08.pdf · PRIMERGY BX600 10GbE LAN I/O Module ... Microsoft Windows Server

Table 251: PortMacAddress

6.2.207. Persistent

String Identifier

Persistent

Property Description

This property indicates the persistency status of the SendTargetPortal. If it is set to 'False', the SendTargetPortal is not persistent and if set to 'True', the SendTargetPortal is marked as persistent.

Attributes Read-Write Datatype list. Valid values are - False,True. min Value N/A max Value N/A default Value False Parent GroupName

SendTargetPortal

Table 252: Persistent

6.3. Data Types

Data Type Description U8 8 bit unsigned integer U16 16 bit unsigned integer U32 32 bit unsigned integer BOOLEAN TRUE or FALSE STRING character string with a null termination

IP_ADDRESS

Dotted quad integers. Each value in the dotted quad integer can range from 0 to 255. Certain combinations (even though with the range) are reserved and cannot be used as IP address. Set operations on such IP addresses will fail with "Invalid Parameter" return status.

Table 253: Data Types

6.4. Common Error Messages

The following are common error messages for all command returning from SM-CLP:

Failed Version mismatch Not Implemented Resource Busy Unknown Error Invalid Value Invalid Value for parameter Value out of range Invalid number of characters Invalid value Parameter Missing Array length small