Long-Baseline Neutrino FacilityLBNF
Print Package Review & Major Electrical Requirements
131.01.03.03.02.04.02 Primary Water LCW System
131.01.03.03.02.04.03 Electrical Bus
Noah Curfman
October 31, 2019
Primary Beamline
Low Conductivity Water (LCW)
Preliminary Design Review
![Page 2: Primary Beamline Low Conductivity Water (LCW) Preliminary](https://reader031.vdocuments.us/reader031/viewer/2022012505/617fcc5bbe1de96c92297583/html5/thumbnails/2.jpg)
LBNF10.31.19 Noah Curfman | Primary Beamline LCW Preliminary Design Review2
LBNF-05 Magnet LCW Overall Flow Schematic
![Page 3: Primary Beamline Low Conductivity Water (LCW) Preliminary](https://reader031.vdocuments.us/reader031/viewer/2022012505/617fcc5bbe1de96c92297583/html5/thumbnails/3.jpg)
LBNF
LBNF-05 Magnet LCW Overall Flow Schematic
Noah Curfman | Primary Beamline LCW Preliminary Design Review3
Remotely operated 3-way valve Primary LCW pumps
Heat Exchanger Bypass Pump Diagram
10.31.19
![Page 4: Primary Beamline Low Conductivity Water (LCW) Preliminary](https://reader031.vdocuments.us/reader031/viewer/2022012505/617fcc5bbe1de96c92297583/html5/thumbnails/4.jpg)
LBNF
LBNF-05 Magnet LCW Overall Flow Schematic
10.31.19 Noah Curfman | Primary Beamline LCW Preliminary Design Review4
Standard DI/Filtration loop
Remotely operated electric valve
![Page 5: Primary Beamline Low Conductivity Water (LCW) Preliminary](https://reader031.vdocuments.us/reader031/viewer/2022012505/617fcc5bbe1de96c92297583/html5/thumbnails/5.jpg)
LBNF
LBNF – 5 Service Building LCW Piping Arrangement
Noah Curfman | Primary Beamline LCW Preliminary Design Review5 10.31.19
![Page 6: Primary Beamline Low Conductivity Water (LCW) Preliminary](https://reader031.vdocuments.us/reader031/viewer/2022012505/617fcc5bbe1de96c92297583/html5/thumbnails/6.jpg)
LBNF
• Bus will run directly
above power supplies
• Indicated crossover will
not occur in practice
LBNF – 5 Service Building LCW Piping Arrangement
Noah Curfman | Primary Beamline LCW Preliminary Design Review6 10.31.19
![Page 7: Primary Beamline Low Conductivity Water (LCW) Preliminary](https://reader031.vdocuments.us/reader031/viewer/2022012505/617fcc5bbe1de96c92297583/html5/thumbnails/7.jpg)
LBNF
LBNF – 5 Service Building LCW Piping Arrangement
Noah Curfman | Primary Beamline LCW Preliminary Design Review7
• Previously specified aluminum
monocoque shielding for bus
no longer suitableMore complex bus
routing incompatible with monocoque shielding
10.31.19
![Page 8: Primary Beamline Low Conductivity Water (LCW) Preliminary](https://reader031.vdocuments.us/reader031/viewer/2022012505/617fcc5bbe1de96c92297583/html5/thumbnails/8.jpg)
LBNFNoah Curfman | Primary Beamline LCW Preliminary Design Review8 10.31.19
Reverse return reduces dP variances between magnets
LBNF Primary Beamline LCW & Bus Flow Schematic
![Page 9: Primary Beamline Low Conductivity Water (LCW) Preliminary](https://reader031.vdocuments.us/reader031/viewer/2022012505/617fcc5bbe1de96c92297583/html5/thumbnails/9.jpg)
LBNF
LBNF Primary Beamline LCW & Bus Flow Schematic
10.31.19 Noah Curfman | Primary Beamline LCW Preliminary Design Review9
Standard dipole/quad/dipole cell
2”x2” to 1”x4” bus connector without LCW pass-thru
Recirculation jumper
![Page 10: Primary Beamline Low Conductivity Water (LCW) Preliminary](https://reader031.vdocuments.us/reader031/viewer/2022012505/617fcc5bbe1de96c92297583/html5/thumbnails/10.jpg)
LBNF
LBNF Primary Beamline LCW & Bus Flow Schematic
Noah Curfman | Primary Beamline LCW Preliminary Design Review10
Air separators at tunnel crestRemotely operated electric valves
LBNF LCW Fill System Beamline Tunnel Crest
10.31.19
![Page 11: Primary Beamline Low Conductivity Water (LCW) Preliminary](https://reader031.vdocuments.us/reader031/viewer/2022012505/617fcc5bbe1de96c92297583/html5/thumbnails/11.jpg)
LBNF
LBNF – 5 Service Building Power Supply P&ID
Noah Curfman | Primary Beamline LCW Preliminary Design Review11 10.31.19
![Page 12: Primary Beamline Low Conductivity Water (LCW) Preliminary](https://reader031.vdocuments.us/reader031/viewer/2022012505/617fcc5bbe1de96c92297583/html5/thumbnails/12.jpg)
LBNF
LBNF – 5 Service Building Power Supply P&ID
Noah Curfman | Primary Beamline LCW Preliminary Design Review12
• One flow control valve per
power supply
• Bus jumpers between A/B
power supplies are external
Griswold Flow Control Valves
10.31.19
![Page 13: Primary Beamline Low Conductivity Water (LCW) Preliminary](https://reader031.vdocuments.us/reader031/viewer/2022012505/617fcc5bbe1de96c92297583/html5/thumbnails/13.jpg)
LBNF
LBNF – 20 Target Hall Power Supply P&ID
Noah Curfman | Primary Beamline LCW Preliminary Design Review13 10.31.19
![Page 14: Primary Beamline Low Conductivity Water (LCW) Preliminary](https://reader031.vdocuments.us/reader031/viewer/2022012505/617fcc5bbe1de96c92297583/html5/thumbnails/14.jpg)
LBNF
Instrumentation
• Designed based on MI and similar LCW Systems
• Detailed estimates and info found in DUNE DocDB Doc #9955
• Specific component selection delayed to take advantage of
emerging technologies
Noah Curfman | Primary Beamline LCW Preliminary Design Review14 10.31.19
![Page 15: Primary Beamline Low Conductivity Water (LCW) Preliminary](https://reader031.vdocuments.us/reader031/viewer/2022012505/617fcc5bbe1de96c92297583/html5/thumbnails/15.jpg)
LBNF
System Redundancy
• Two 150HP Pumps, one running, one hot spare
• Both pumps VFD controlled
• All major components may be valved out for replacement
• Filters
• DI bottles
• Power supplies
• Instrumentation
• Magnet cells
• Recirculation jumpers on all supply/returns
10.31.19 Noah Curfman | Primary Beamline LCW Preliminary Design Review15
![Page 16: Primary Beamline Low Conductivity Water (LCW) Preliminary](https://reader031.vdocuments.us/reader031/viewer/2022012505/617fcc5bbe1de96c92297583/html5/thumbnails/16.jpg)
LBNF
Electrical Requirements
• 2 primary circulation pumps with VFDs
• 3 electrically actuated valves
- 1 valve in pump room
- 2 valves in beam enclosure
• 1 three-way valve to control HX flow
Noah Curfman | Primary Beamline LCW Preliminary Design Review16
Power RequirementsQuantity Rated Power Voltage Input Phase I @ Full Load I @ Stall
Primary Pumps 2 150 HP 480 V Three 177 A 969.4 A
Recirculation Pump 1 1/2 HP 480 V Three 2.2 A Not Listed
Primary Pump VFDs 2 150 HP 480 V Three 180A N/A
3 Way Valve Actuator 1 1/12 HP 480 V Three 0.32 A 1.16 A
Electrically Operated Valves 3 0.5 HP 120 V Single Not Listed 3A (est.)
Control Panel 1 N/A 110V Single 15A N/A
10.31.19
![Page 17: Primary Beamline Low Conductivity Water (LCW) Preliminary](https://reader031.vdocuments.us/reader031/viewer/2022012505/617fcc5bbe1de96c92297583/html5/thumbnails/17.jpg)
LBNF
LBNF Vehicle Access Tunnel LCW Piping & Bus Layout
Noah Curfman | Primary Beamline LCW Preliminary Design Review17 10.31.19
![Page 18: Primary Beamline Low Conductivity Water (LCW) Preliminary](https://reader031.vdocuments.us/reader031/viewer/2022012505/617fcc5bbe1de96c92297583/html5/thumbnails/18.jpg)
LBNF
LBNF Beamline LCW Pipe & Bus Routing
Noah Curfman | Primary Beamline LCW Preliminary Design Review18
• Provides maximum room for cable trays in alcove
• 2” LCW Downstream return continues into alcove for Q211
10.31.19
![Page 19: Primary Beamline Low Conductivity Water (LCW) Preliminary](https://reader031.vdocuments.us/reader031/viewer/2022012505/617fcc5bbe1de96c92297583/html5/thumbnails/19.jpg)
LBNF
Full Layout Envelope Showing Bus LCW Cable Trays and Headers
Noah Curfman | Primary Beamline LCW Preliminary Design Review19
Full envelope layout showing all possible components along
beamline wall
10.31.19
![Page 20: Primary Beamline Low Conductivity Water (LCW) Preliminary](https://reader031.vdocuments.us/reader031/viewer/2022012505/617fcc5bbe1de96c92297583/html5/thumbnails/20.jpg)
LBNF
Full Layout Envelope Showing Bus LCW Cable Trays and Headers
Noah Curfman | Primary Beamline LCW Preliminary Design Review20
Full envelope layout showing all possible components along
beamline wall
10.31.19
![Page 21: Primary Beamline Low Conductivity Water (LCW) Preliminary](https://reader031.vdocuments.us/reader031/viewer/2022012505/617fcc5bbe1de96c92297583/html5/thumbnails/21.jpg)
LBNF
System Design Requirements
• Meet previously described operational goals
• Require minimal unscheduled interventions
• Meet established lab standards for flow and capacity
• Operate over a range of elevations determined by CF
• Use pond water for cooling and MI LCW for fill
• Conform to ASME B31.3 and FESHM 5031.1
Noah Curfman | Primary Beamline LCW Preliminary Design Review21
Fluid Low Conductivity Water
Resistivity 9MΩ·cm or better
Nominal Temperature 95°F
Radioactivity < 1900 pCi/ml
MAWP 200 psig
10.31.19